1.
Rev. gaúch. enferm ; 40(spe): e20180344, 2019.
Article in Portuguese | LILACS, BDENF | ID: biblio-1357348

ABSTRACT

Resumo OBJETIVO Relatar a atuação da equipe multidisciplinar na comunicação efetiva e no cuidado seguro aos pacientes com dispositivo de assistência ventricular. MÉTODO Relato de experiência sobre o uso da comunicação efetiva no cuidado a pacientes com dispositivo de assistência ventricular em hospital universitário do sul do Brasil. A referida assistência iniciou em 2017, pautada na individualização das ações e na perspectiva do cuidado centrado no paciente. RESULTADOS Na instituição foram capacitadas equipes multiprofissionais, estruturados protocolos assistenciais, realizadas sessões educativas sistemáticas para pacientes e cuidadores. Foram executadas visitas domiciliares para planejamento de alta hospitalar e plano para situações de urgência, além de capacitações básicas para as equipes dos hospitais próximos à residência dos pacientes. CONCLUSÕES A comunicação efetiva entre equipe multiprofissional, pacientes e cuidadores no planejamento do cuidado em saúde tem papel fundamental para identificar precocemente possíveis complicações, preveni-las e possibilitar maior sobrevida e qualidade de vida a esses pacientes.


Resumen OBJETIVO Informar la actuación del equipo multidisciplinario en la comunicación efectiva y cuidado seguro a los pacientes con dispositivo de asistencia ventricular. MÉTODO Se trata de un relato de experiencia sobre el uso de la comunicación efectiva en la asistencia a pacientes con dispositivo de asistencia ventricular em un hospital universitario del sur de Brasil. Esse cuidado, inició en 2017, pautado em la individualización de las acciones y em la perspectiva del cuidado centrado em el paciente. RESULTADOS En la institución se capacitaron equipos multiprofissionales, estructurados protocolos asistenciales, realizadas sesiones educativas sistemáticas para pacientes y cuidadores, visita domiciliares para la planificación de alta hospitalaria y plan para situaciones de urgência, además de capaccitaciones de urgência, además de capacitaciones básicas para los equipos de los hospitales cercanos a la residencia de los pacientes. CONCLUSIONES La comunicación efectiva entre el equipo multiprofesional, pacientes y familiares en la planificación del cuidado en salud tiene un papel fundamental para identificar precozmente posibles complicaciones, prevenirlas y posibilitar mayor sobrevida y calidad de vida.


Abstract OBJECTIVE To report the role of multiprofessional teams in the effective communication and safe care of patients with left ventricular assist device. METHODS This is an experience report about the use of effective communication for patients with ventricular assist device in a university hospital in southern Brazil. Care based on individualized action and centered on the patients started in 2017. RESULTS At the institution, the multiprofessional teams attended training sessions and care protocols were established. The patients and caregivers attended systematic educational sessions and home visits were made to arrange patient discharge and urgency plans. Also, the hospital teams located near the patients' homes received basic training. CONCLUSION Effective communication between multiprofessional teams, patients, and their families when planning care plays a pivotal role in the early identification of possible complications and their prevention, resulting in a greater survival rate and a better quality of life.


Subject(s)
Humans , Silicones , Suture Techniques/education , Simulation Training/methods , Models, Anatomic , Students, Medical , Surveys and Questionnaires , Reproducibility of Results , Clinical Competence , Education, Medical, Undergraduate/standards , Education, Medical, Undergraduate/methods , Simulation Training/standards , Academic Performance
2.
Rev. SOBECC ; 21(1)jan.-mar. 2016. tab
Article in Portuguese | LILACS, BDENF | ID: lil-784422

ABSTRACT

Objetivo: Analisar na literatura científica a prática clínica do enfermeiro ao paciente em uso de assistência circulatória mecânica. Método: Revisão integrativa da literatura realizada nas bases de dados SciELO, Cochrane Library, PubMed e LILACS, de abril a agosto de 2014. Resultados: Embora haja avanço em pesquisas sobre o tema, ainda há poucos estudos, haja vista oito artigos selecionados. Três artigos apontam para a necessidade do enfermeiro deter o conhecimento sobre assistência circulatória mecânica, para uma assistência eficiente e com qualidade. Dois artigos trouxeram a assistência de enfermagem a pacientes em uso de dispositivos. Três relataram complicações devido ao uso do balão intra-aórtico e mostraram que as complicações podem ser minimizadas a partir da capacitação e da avaliação clínica periódica do enfermeiro. Conclusão: Há poucos estudos direcionados à assistência de enfermagem, havendo a necessidade de maior exploração do tema para subsidiar a prática baseada em evidências cientificas.


Objetivo: Analizar en la literatura científica la práctica clínica de las enfermeras a los pacientes utilizándose del soporte circulatorio mecánico. Método: Revisión integradora de la literatura conducida en las bases de datos SciELO, Cochrane Library, PubMed y LILACS, desde abril hasta agosto de 2014. Resultados: Aunque hay avances en la investigación sobre el tema, hay pocos estudios, con solo ocho artículos seleccionados. Tres artículos apuntan a la necesidad de las enfermeras detener los conocimientos sobre soporte circulatorio mecánico para el servicio eficiente y de calidad. Dos artículos presentaron la atención de la enfermería a los pacientes que utilizan dispositivos. Tres estudios informaron complicaciones por la utilización de balón intra-aórtico y mostraron que las complicaciones pueden reducirse al mínimo basándose en la formación y la evaluación clínica periódica de la enfermera. Conclusión: Hay pocos estudios con foco en la atención de la enfermería, y una necesidad de una mayor exploración del tema, para subsidiar la práctica basada en evidencias científicas.


Objective: To analyze in the scientific literature the clinical practice of nurses with patients in use of mechanical circulatory support. Method: Integrative literature review conducted in the databases SciELO, Cochrane Library, PubMed and LILACS, from April to August 2014. Results: Although there is progress in research on the topic, there are few studies, given the eight articles selected. Three articles point to the need for nurses to detain knowledge about mechanical circulatory support for efficient service and quality. Two articles brought the nursing care to patients using devices. Three studies reported complications due to the use of intra-aortic balloon and showed that complications can be minimized through training and periodic clinical assessment of the nurse. Conclusion: There were few articles found, highlighting the need for further exploration of the subject, especially with regard to nursing care.


Subject(s)
Humans , Automation , Intra-Aortic Balloon Pumping , Nursing Care , Review , Ventricular Remodeling , Heart Failure
5.
Rev. bras. cir. cardiovasc ; 27(4): 552-561, out.-dez. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-668117

ABSTRACT

OBJETIVO: Este estudo avaliou o desempenho hemodinâmico e as alterações miocárdicas decorrentes do emprego de dispositivos de assistência ventricular esquerda (DAVE), associado ou não à descompressão do ventrículo direito por meio de derivação cavo-pulmonar, sendo esses achados comparados ao emprego de assistência circulatória biventricular. MÉTODOS: Vinte e um suínos foram submetidos à indução de insuficiência cardíaca através de fibrilação ventricular, sendo a atividade circulatória mantida por DAVE durante 180 minutos. No grupo controle, foi apenas implantado o DAVE. No grupo derivação, além do DAVE foi realizada cirurgia de derivação cavo-pulmonar. No grupo biventricular, foi instituída assistência biventricular. Foram monitoradas as pressões intracavitárias por 3 horas de assistência e amostras do endocárdio dos dois ventrículos foram coletadas e analisadas à microscopia óptica e eletrônica. RESULTADOS: O lactato sérico foi significativamente menor no grupo biventricular (P=0,014). A diferença observada entre o fluxo do DAVE nos grupos derivação e controle (+55±14 ml/kg/min, P=0,072) não foi significativa, enquanto que o fluxo no grupo biventricular foi significativamente maior (+93±17 ml/kg/min, P=0,012) e se manteve estável durante o experimento. A pressão arterial média (PAM) se manteve constante apenas no grupo biventricular (P<0,001), que também apresentou diminuição significativa das pressões em câmaras direitas. Na análise ultraestrutural, notou-se menor presença edema miocárdico no ventrículo direito no grupo biventricular (P=0,017). CONCLUSÃO: Os resultados apresentados demonstram que o desempenho hemodinâmico da assistência ventricular esquerda associada à derivação cavo-pulmonar, neste modelo experimental, não foi superior ao observado com a assistência de ventrículo esquerdo isolada e não substituiu a assistência biventricular de maneira efetiva.


OBJECTIVE: Right ventricular (RV) failure during left ventricular assist device (LVAD) support can result in severe hemodynamic compromise with high mortality. This study investigated the acute effects of cavo-pulmonary anastomosis on LVAD performance and RV myocardial compromise in comparison with biventricular circulatory support, in a model of biventricular failure. METHODS: LVAD support was performed by centrifugal pump in 21 pigs with severe biventricular failure obtained by FV induction. Animals were randomized to be submitted to cavo-pulmonary anastomosis, to biventricular circulatory support or to control group. They were maintained under circulatory support and hemodynamic monitoring for 3h. Venous lactate and cytokines serum levels were also obtained. Endocardium samples were analyzed by electronic microscopy. RESULTS: FV maintenance was responsible for acute LVAD impairment after 180 min in the control group. cavo-pulmonary anastomosis resulted in non-significant improvement of LVAD pump flow in relation to control group (+55±14 ml/kg/min, P=0.072), while animals under biventricular support maintained higher LVAD flow (+93±17 ml/kg/min, P=0.012). Mean arterial pressure remained constant only in biventricular group (P<0.001), which also presented decrease of right atrial and ventricular pressures. Similar increases in lactate and cytokines levels were observed in the three groups. Ultra-structural analysis documented low levels of myocardial swelling in the biventricular group (P=0.017). CONCLUSION: The concomitant use of cavo-pulmonary anastomosis during LVAD support in a pig model of severe biventricular failure resulted in non-significant improvement of hemodynamic performance and it did not effectively replace the use of biventricular support.


Subject(s)
Animals , Heart Bypass, Right/methods , Heart Failure/surgery , Heart Ventricles/ultrastructure , Heart-Assist Devices/adverse effects , Hemodynamics/physiology , Ventricular Dysfunction, Right/physiopathology , Cytokines/blood , Disease Models, Animal , Heart Failure/blood , Lactic Acid/blood , Random Allocation , Statistics, Nonparametric , Swine , Ventricular Dysfunction, Right/surgery
6.
Rev. bras. cir. cardiovasc ; 26(1): 76-85, jan.-mar. 2011. ilus, tab
Article in Portuguese | LILACS, SES-SP | ID: lil-624495

ABSTRACT

OBJETIVO: Apresentar os resultados da aplicação deste dispositivo em animais de experimentação, promovendo auxílio hemodinâmico apenas ao ventrículo esquerdo (VE). MÉTODOS: Entre junho 2002 e outubro 2009, foram implantados em 27 bezerros com idade 2½ a 4 meses e peso 80/100 kg e, por meio de anestesia geral e ventilação controlada e de toracotomia lateral esquerda, era introduzida cânula no ápice do VE e anastomose término/lateral de tubo vascular de politetrafluoretileno (PTFE) com a porção descendente da aorta torácica, ambos interligados ao dispositivo implantado no subcutâneo abaixo do diafragma (24) e intratorácico (três). Em cinco bezerros, o dispositivo foi aplicado com auxílio de circulação extracorpórea (CEC) e, em 22, sem CEC. RESULTADOS: Ocorreram dois óbitos durante o implante e três por causas diversas nas primeiras horas de pós-operatório (PO), sendo um relacionado ao dispositivo. A sobrevivência entre o 1º e 6º dia de PO ocorreu em 17 animais e entre o 8º e 31º dia de PO em cinco, com causas determinantes diversas, não só por problemas clínico/cirúrgicos, mas também relacionados ao dispositivo. O impacto hemodinâmico avaliado pela análise da pressão sistêmica mostrou incremento que variou de 20 a 40 mmHg e os dados laboratoriais analisados demonstraram baixos impactos traumáticos à crase sanguínea e boa biocompatibilidade. CONCLUSÃO: Trata-se de pesquisa árdua e complexa onde a cada experimento são identificados problemas não só de implantabilidade, mas também relacionados ao dispositivo, que vão sendo sistematicamente corrigidos, tornando-o cada vez mais seguro e eficaz.


OBJECTIVE: The objective is to present the results of the application this device in experimental animals unloading only the left ventricle. METHODS: Between June 2002 and October 2009, were implanted in 27 calfs with age between 2½ to 4 months and 80 to 100 kg of weight, with general anaesthesia and controled ventilation, by mean of left thoracotomy a cannula in the apex of VE and a lateral anastomose of a GTFE vascular graft tube in the descending portion of the thoracic aorta, both connected to the device implanted below the diaphragm in the subcutaneous (24) and intrathoracic (three). The cardiopulmonary bypass (BP) was used in five calves, and directly introduce the outflow cannula in 22. RESULTS: During the implant two and in the first hours of the post operative period (PO) three deaths were observed, one related to the device. The survival between the first and the six PO day was found in 17 calves and between day 8 and day 31 (PO) in five all caused by clinical/surgical problems, and related to the device. The hemodynamic impact by the systemic pressure analysis showed 20 to 40 mmHg increase and the laboratory parameters showed lower levels of traumatic impact to the blood and a good biocompatibility. CONCLUSIONS: This kind of research is arduous and complex where at each experiment many problems are indentified in the implantability and in the device, which are sistematic correct, to became device/procedure safe and effective.


Subject(s)
Animals , Cattle , Female , Biocompatible Materials , Heart Valve Prosthesis Implantation/methods , Heart Ventricles/surgery , Heart-Assist Devices , Heart Valve Prosthesis Implantation/mortality , Hemodynamics/physiology , Models, Animal , Models, Cardiovascular , Pacemaker, Artificial , Prospective Studies , Prosthesis Design
7.
Arq. bras. cardiol ; 91(5): 327-334, nov. 2008. ilus, graf, tab
Article in English, Portuguese | LILACS | ID: lil-501812

ABSTRACT

FUNDAMENTO: O transplante cardíaco enfrenta o grave problema da escassez de doadores. Estima-se que entre 20 por cento e 40 por cento dos pacientes falecem na fila de espera. Para esses pacientes, a utilização de dispositivos de assistência circulatória é, muitas vezes, a única possibilidade de sobrevivência durante a espera do doador. No Brasil, não existe nenhum programa regular de utilização desses dispositivos como ponte para transplante. OBJETIVO: Avaliar o desempenho hemodinâmico e a resposta inflamatória durante a utilização do DAV-InCor como ponte para transplante. MÉTODOS: Entre outubro de 2003 e abril de 2006, 11 pacientes, indicados em caráter de prioridade para o transplante cardíaco, evoluíram em choque cardiogênico refratário. O implante do DAV-InCor foi realizado em sete pacientes. O diagnóstico etiológico foi cardiopatia chagásica em cinco pacientes e cardiomiopatia dilatada idiopática em dois. RESULTADOS: A assistência mecânica ao ventrículo esquerdo foi mantida nos sete pacientes por períodos entre 14 e 42 dias (média 26,2). O desempenho hemodinâmico foi adequado, com a normalização do índice cardíaco, dos níveis de saturação venosa de O2 e do lactato. O transplante foi realizado em dois pacientes, os outros cinco faleceram por infecção sistêmica ou falência de múltiplos órgãos. CONCLUSÃO: O desempenho do DAV-Incor, no comportamento hemodinâmico dos pacientes estudados, foi adequado para a manutenção de uma condição circulatória satisfatória durante o período estudado. Houve melhora dos parâmetros de perfusão tecidual e manutenção de sinais de resposta inflamatória sistêmica. Houve alta incidência de complicações; contudo, não foram demonstradas complicações relacionadas ao dispositivo que comprometam a segurança da utilização do mesmo.


BACKGROUND: Cardiac transplantation faces the serious problem of lack of donors and it is estimated that 20 to 40 percent of the patients die while waiting for heart transplantation. For these patients, the use of mechanical circulatory assist devices is the only choice of survival while waiting for a donor. In Brazil, the experience with mechanical circulatory support is limited and there is no regular program regarding the use of these devices as a bridge to heart transplantation. OBJECTIVE: To evaluate the hemodynamic performance and the systemic inflammatory response during the clinical use of the InCor-type ventricular assist device (VAD-InCor) as a bridge to heart transplantation. METHODS: Between October 2003 and April 2006, 11 patients in the waiting list for heart transplantation presented hemodynamic deterioration due to refractory cardiogenic shock. Seven of these patients were submitted to VAD-InCor implantation for left ventricular assistance. The etiologic diagnosis was Chagas' disease in 5 patients and idiopathic dilated cardiomyopathy in 2. RESULTS: The duration of left ventricular assistance ranged from 14 to 42 days (mean 26.2 days). During this period, the hemodynamic performance of the DAV-InCor was adequate to support a normal hemodynamic state. There was normalization of central venous oxygen saturation and serum lactate. Two patients were submitted to heart transplantation, while the other 5 patients died under assistance due to infection and multiple organ failure. CONCLUSION: The performance of the VAD-InCor, in the hemodynamic behavior of the studied patients, was adequate for the maintenance of a satisfactory circulatory state during the studied period. There was improvement in the tissue perfusion parameters and maintenance of systemic inflammatory response signs. There was a high incidence of complications; however, complications related to the device, which could compromise the safety of its use, were not demonstrated.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Cardiomyopathy, Dilated/physiopathology , Chagas Cardiomyopathy/physiopathology , Heart-Assist Devices , Hemodynamics/physiology , Inflammation Mediators/blood , Biomarkers/blood , C-Reactive Protein/analysis , Cardiomyopathy, Dilated/blood , Cardiomyopathy, Dilated/surgery , Chagas Cardiomyopathy/blood , Chagas Cardiomyopathy/surgery , Heart Transplantation , /blood , /blood , Statistics, Nonparametric , Tumor Necrosis Factor-alpha/blood , Waiting Lists
8.
São Paulo; s.n; 2008. [86] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-586862

ABSTRACT

Introdução: A utilização de dispositivos de assistência ventricular esquerda (DAVE) proporciona melhor manejo dos pacientes que necessitam de métodos alternativos como ponte para o transplante cardíaco. Parcela significativa dos pacientes sob uso de DAVE desenvolve falência de ventrículo direito (VD), com elevada mortalidade. Propusemos estudo experimental para desenvolvimento de método de descompressão do VD em pacientes sob assistência mecânica esquerda e disfunção biventricular. Método: Foi realizado estudo experimental em cães adultos, com disfunção biventricular em fibrilação ventricular, mantidos em uso de DAVE com bomba centrífuga. Os animais foram divididos em dois grupos. No Grupo A, foi realizada descompressão do VD através de anastomose cavo-pulmonar, com anastomose da veia cava superior na artéria pulmonar direita. No grupo B, não foi realizado o "shunt". Após o preparo inicial foi iniciada assistência circulatória átrio esquerdo-aorta. Foram realizadas medidas hemodinâmicas e laboratoriais no momento inicial e aos 30, 60 e 90 minutos de assistência nos dois grupos. Resultados: Os dados hemodinâmicos e laboratoriais iniciais foram semelhantes nos dois grupos. No Grupo A, houve melhora da pressão arterial media (p<0,0001) durante a assistência. O fluxo pulmonar também foi maior no grupo A (p<0,0001), resultando em maior fluxo na bomba centrífuga, principalmente aos 90 min(1,2L/min X 0,5L/min, p<0,0001). A dosagem de lactato sérico no último momento de estudo foi menor no grupo A (27,6mg/dL versus 47,6mg/dL, p<0,05). Conclusão: Concluímos que a anastomose cavo-pulmonar promove descompressão do VD em modelo de disfunção bi-ventricular aguda sob assistência circulatória isolada do ventrículo esquerdo. A descompressão do VD leva a aumento do fluxo pulmonar e melhor desempenho hemodinâmico da assistência ao ventrículo esquerdo.


Introduction: The use of Left Ventricular Assist Devices promotes better clinical handling of patients in the need of alternative methods as bridge to heart transplant. A significant part of them develop right ventricle failure, leading to high death incidence. We have proposed an experimental study for the development of a method to decompress the right ventricle in biventricular failure patients under Left Ventricular Assist Devices . Method: Experimental study with adult dogs with acute biventricular failure in ventricular fibrillation under left assist device by centrifugal pump. The animals were divided in 2 groups. In Group A decompression of RV was made by cavo-pulmonary anastomosis between superior vena cava and right pulmonary artery. In Group B the anastomosis was not performed. After initial preparation left atrium-aorta circulatory support begun. Hemodinamic and laboratory measures were taken at start time and at 30, 60 and 90 minutes of circulatory support. Results: Initial laboratory and haemodinamic data were similar in both groups. Group A had better mean arterial pressure during support(p<0,0001). Pulmonary blood flow was higher in Group A resulting in higher pump flow, mainly at 90 minutes(1,2L/minX0,5L/min, p<0,0001). Serum lactate was lower at 90 minutes in Group A(27,6mg/dL x 47,6mg/dL, p<0,05). Conclusion: We conclude that the cavo-pulmonary anastomosis led to right ventricle decompression in an experimental model of acute biventricular failure under isolated left ventricle circulatory support. The right ventricle decompression generated enhancement in pulmonary blood flow and better circulatory support performance.


Subject(s)
Animals , Dogs , Heart Bypass, Right , Heart Failure , Heart-Assist Devices
9.
Rev. bras. cir. cardiovasc ; 22(2): 224-234, abr.-jun. 2007. ilus, tab, graf
Article in Portuguese | LILACS, SES-SP | ID: lil-461764

ABSTRACT

INTRODUÇÃO: O trabalho aborda projeto original relativo à concepção, ao desenvolvimento e à aplicação clínica de bomba sangüínea que associa forças centrífuga e axial de propulsão hidráulica, baseada no princípio de Arquimedes, denominada Bomba Espiral (BE), tendo recebido Patente Nacional e Relatório Preliminar Internacional categorizando-a como invento. MÉTODO: Visa avaliar sua capacidade hidrodinâmica e seu impacto aos elementos figurados do sangue por meio de testes "in vitro", como Eficiência Hidrodinâmica, Hemólise Normalizada e Visibilização de Escoamento, e, nos testes "in vivo" experimentais, feitos em carneiros submetidos a Circulação Extracorpórea (CEC), e clínico, em 43 pacientes submetidos a operações cardíacas com CEC, nas quais o elemento propulsor foi a BE. RESULTADOS: Na dependência da distância entre o rotor e a carcaça (fenda) da bomba pôde-se observar que com 1,5 mm gerou escoamento ao redor de 9 L/min, pressão acima de 400mmHg com 1500 rotações por minuto (rpm), índices de Hemólise Normalizada não superiores a 0,0375 g/100l em condições de alto fluxo e pressão, e pelo estudo de Visibilização do Escoamento no interior da bomba não se detectou áreas de estagnação ou turbulência na entrada, saída e junto à extremidade dos fusos. Nas pesquisas "in vivo" experimentais em ovinos em CEC por 6 horas a BE foi capaz de manter parâmetros pressóricos adequados e Hemoglobina Livre entre 16,36 mg por cento e 44,90 mg por cento. Durante sua aplicação em cirurgias cardíacas com CEC, num grupo de 43 pacientes, pôde-se constatar variações pré e pós-CEC, na Hemoglobina Livre de 9,34 a 44,16 mg por cento, no Fibrinogênio, de 236,65 a 547,26 mg por cento, na contagem do número de Plaquetas de 152,465 a 98,139, Desidrogenase Láctica, de 238,12 a 547,26 mg por cento, com tempo de coagulação ativada ao redor de 800 seg. quando em CEC. CONCLUSÕES: A BE mostrou resolutividade por gerar escoamento e pressão adequados, sem causar danos excessivos...


INTRODUCTION: This paper addresses an original project that encompasses the conception, development and clinical application of a helical bypass pump called the Spiral Pump, that uses the association of centrifugal and axial propulsion forces based de the Archimedes principle. This project has obtained a Brazilian Patent and an International Preliminary Report, defining it as an invention. METHODS: The aim of this work was to evaluate the hemodynamic capacity and the impact of its application on blood cells by means of experimental in vitro tests, including hydrodynamic efficiency, effect on hemolysis and flow visualization. Moreover, in vivo experimental tests were carried out on lambs that were submitted to cardiopulmonary bypass for six hours and in 43 patients submitted to heart bypass surgery using the Spiral Pump. RESULTS: When the rotor-plastic casing gap was 1.5mm, the flow generated was nearly 9 L/min, the pressure was greater than 400 mmHg at 1500 rpm, and the normalized hemolytic indexes were not greater than 0.0375 g/100L in high-flow and pressure conditions. Additionally, by the flow visualization techniques, stagnation was not seen inside the pump nor was turbulence identified at the entrance or exit of the pump, or at the ends of the spindles. In the in vivo tests using cardiopulmonary bypasses for 6 hours in lambs, the pump maintained adequate pressure rates and the free hemoglobin levels ranged between 16.36 mg percent and 44.90 mg percent. Evaluating the results of the 43 patients who used this pump in heart bypass operations we observed that the free hemoglobin ranged from 9.34 mg percent before to 44.16 mg percent after surgery, the serum fibrinogen was from 236.65 mg percent to 547.26mg percent, platelet blood count from 152,465 to 98,139 and the lactic dehydrogenase from 238.12mg percent to 547.26mg percent. The Activated Coagulation Time was close to 800 seconds during the bypass. CONCLUSION: The Spiral Pump was...


Subject(s)
Humans , Animals , Guinea Pigs , Heart-Assist Devices/classification , Cardiovascular Diseases/therapy , Hemolysis , In Vitro Techniques , Animal Experimentation , Human Experimentation , Hydrodynamics , Flow Mechanics
SELECTION OF CITATIONS