Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
CoDAS ; 35(2): e20210201, 2023. tab
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1439934

ABSTRACT

RESUMO Objetivo O objetivo do presente estudo foi traduzir, adaptar e validar transculturalmente a versão para língua portuguesa brasileira do questionário Hearing Protection Assessment Questionnaire (HPA). Método O instrumento original, desenvolvido na língua inglesa, buscou avaliar as barreiras e suportes relacionados ao uso dos dispositivos de proteção auditiva (DPA), assim como o conhecimento, hábitos e atitudes dos trabalhadores frente ao ruído ocupacional. A tradução, adaptação e validação transcultural do questionário foi composta de cinco etapas: Tradução do questionário do inglês para o português; 2) Processo inverso de tradução do português para o inglês; 3) Análise do instrumento por três especialistas na área; 4) Pré-teste do questionário com 10 trabalhadores; 5) Aplicação do instrumento em 509 trabalhadores de uma indústria frigorífica após o exame admissional. Resultados os resultados indicam a validade de construção e conteúdo da versão em Português Brasileiro para o seu uso com uma população trabalhadora e a consistência interna do mesmo. Conclusão Este estudo resultou na tradução, na adaptação cultural e validação do questionário Hearing Protection Assessment Questionnaire (HPA) com a finalidade de ser usado para avaliar o uso de proteção auditiva individual em âmbito ocupacional, denominado Questionário de Avaliação da Proteção Auditiva (APA).


ABSTRACT Purpose The aim of the present study is to translate, adapt, and cross-culturally validate the Brazilian Portuguese version of the questionnaire Hearing Protection Assessment Questionnaire (HPA). Methods The original instrument, developed in English, seeks to assess barriers and supports related to the use of hearing protection devices (HPD), as well as workers' knowledge, habits and attitudes towards occupational noise. The translation, adaptation, and cross-cultural validation of the questionnaire consisted of five steps: Translation of the questionnaire from English to Portuguese; 2) Reverse translation from Portuguese to English; 3) Analysis of the instrument by three experts in the field; 4) Pre-test of the questionnaire with ten workers; 5) Application of the instrument to 509 workers in a meatpacking industry after the pre-employment medical exam. Results The results indicate the construction and content validity of the Brazilian Portuguese version for use with a working population and its internal consistency. Conclusion This study resulted in the translation, cultural adaptation, and validation of the Hearing Protection Assessment Questionnaire (HPA), in order to be used to assess the use of individual hearing protection in the occupational field, called Hearing Protection Assessment Questionnaire (HPA).

2.
Rev. salud pública ; 21(2): 195-201, ene.-abr. 2019. tab, graf
Article in Spanish | LILACS | ID: biblio-1094390

ABSTRACT

RESUMEN Objetivo Verificar los niveles de atenuación de dos tipos de protectores auditivos de copa bajo condiciones reales de operación. Métodos Se realizó un diseño experimental de medidas repetidas de los niveles de presión sonora al interior y exterior de los protectores auditivos, realizando mediciones de ruido bajo circunstancias habituales de trabajo para operadores de una planta de hidrocarburos. Posteriormente, se determinaron las diferencias entre los niveles de atenuación establecidos por el fabricante, los niveles de atenuación ajustados bajo el método recomendado por NIOSH y los niveles de atenuación obtenidos experimentalmente. Resultados Los valores de atenuación ofrecidos por los fabricantes difieren de los obtenidos experimentalmente, siendo estos últimos, menores en todos los casos del estudio. Los valores de atenuación de los protectores auditivos ajustados bajo el método NIOSH alcanzaron valores más cercanos a los experimentales. Conclusiones La variabilidad entre los valores de atenuación teóricos y experimentales, permiten establecer que las estimaciones de los niveles de atenuación obtenidos en condiciones controladas no consideran aspectos que en condiciones reales de uso afectan la eficiencia del protector auditivo. Este estudio plantea la necesidad de implementar programas integrales de protección auditiva, que permitan considerar variables asociadas a la eficacia del dispositivo en condiciones de uso, a través de la aplicación de pruebas de ajuste o en su defecto a través de la aplicación de los factores de ajuste sugeridos por NIOSH, con el fin de realizar una adecuada selección que permita alcanzar un control efectivo para el ruido.


ABSTRACT Objective To verify the attenuation levels of two types of earmuffs under real operating conditions. Materials and Methods A study with experimental design was carried out to obtain repeated measurements of the sound pressure levels inside and outside hearing protectors in a sample of workers of an oil and gas company working under normal process and exposure conditions. The results allowed determining differences between the attenuation levels established by the manufacturer, the adjusted attenuation levels under the NIOSH method, and the attenuation levels obtained experimentally. Results The attenuation values established by the manufacturers are lower than those ones obtained under actual use conditions in all cases evaluated. Likewise, the attenuation values of the hearing protectors, once adjusted under the NIOSH method, reached values much closer to those obtained experimentally. Conclusions The variability between theoretical attenuation values and experimental values allows concluding that the attenuation levels obtained under controlled laboratory conditions do not take into account certain characteristics that, based on their use, affect the efficiency of the hearing protection device. This study encourages the implementation of comprehensive hearing protection programs that consider variables such as hearing protection effectiveness, under real use conditions, by applying fit tests or other adjustment factors like the one suggested by NIOSH. This would ensure an adequate selection that aims at achieving an effective control of this risk factor.


RESUMO Objetivo Verifique os níveis de atenuação de dois tipos de protetores auriculares em condições reais de operação. Métodos Foi realizado um projeto experimental de medições repetidas dos níveis de pressão sonora dentro e fora dos protetores auditivos, fazendo medições de ruído em condições normais de trabalho para operadores de uma usina de hidrocarbonetos. Posteriormente, foram determinadas as diferenças entre os níveis de atenuação estabelecidos pelo fabricante, os níveis de atenuação ajustados pelo método recomendado pelo NIOSH e os níveis de atenuação obtidos experimentalmente. Resultados Os valores de atenuação oferecidos pelos fabricantes diferem daqueles obtidos experimentalmente, sendo este último menor em todos os casos do estudo. Os valores de atenuação dos protetores auditivos ajustados pelo método NIOSH atingiram valores mais próximos aos experimentais. Conclusões A variabilidade entre os valores de atenuação teórica e experimental permite estabelecer que as estimativas dos níveis de atenuação obtidos em condições controladas não consideram aspectos que, em condições reais de uso, afetam a eficiência do protetor auditivo. Este estudo levanta a necessidade de implementar programas abrangentes de proteção auditiva que permitam considerar variáveis associadas à efetividade do dispositivo em condições de uso, através da aplicação de testes de adaptação ou, na sua falta, através da aplicação de ajuste sugerido pelo NIOSH, a fim de fazer uma seleção adequada para obter um controle eficaz do ruído.(AU)


Subject(s)
Humans , Occupational Exposure/standards , Ear Protective Devices/standards , Radiation Dosimeters , Noise, Occupational/prevention & control , Clinical Trial , Noise Measurement/methods
3.
Einstein (Säo Paulo) ; 17(2): eAO4423, 2019. tab, graf
Article in English | LILACS | ID: biblio-989779

ABSTRACT

ABSTRACT Objective To analyze the incidence of otorrhea in the postoperative period of patients submitted to tympanotomy to place ventilation tube, and who did not protect the ear when exposed to water. Methods Open, randomized-controlled trial. Eighty patients submitted to unilateral or bilateral ear grommet tympanostomy were included and divided into two groups: Auricular Protection and Non-Protection to water during bathing and activities in water. Results In the first postoperative month, the Non-Protection Group presented a significant increase in the number of patients with otorrhea and in the incidence. Four patients of the Protection Group (11%) presented at least one episode of otorrhea in this period, representing an incidence of 0.11 (standard deviation ±0.32) episode/month, whereas in the Non-Protection Group there were 12 episodes (33%; p=0.045) and incidence of 0.33 (±0.48; p=0.02). Between the 2nd and the 13th postoperative months, there was no difference between groups. Seven patients in the Protection Group (20%) had at least one episode of otorrhea, representing an incidence of 0.04 (±0.09) episodes/month, while in the Non-Protection Group there were seven episodes (22%; p=0.8) and incidence of 0.05 (±0.1; p=0.8). Conclusion Patients who underwent ear protection when exposed to water had a lower incidence of otorrhea in the first postoperative month than those who did not undergo protection. From the second month, there was no difference between groups.


RESUMO Objetivo Avaliar a incidência de otorreia no período pós-operatório em pacientes submetidos à timpanotomia para colocação de tubo de ventilação e que não realizaram proteção auricular quando expostos à água. Métodos Ensaio clínico controlado, aberto e randomizado. Foram incluídos 80 pacientes submetidos à timpanotomia para colocação de tubo de ventilação unilateral ou bilateral, divididos em dois grupos: Grupo Proteção e Grupo Não Proteção auricular da água durante o banho e as atividades aquáticas. Resultados No primeiro mês pós-operatório, o Grupo Não Proteção apresentou aumento significativo tanto no número de pacientes com otorreia quanto na incidência. Quatro pacientes do Grupo Proteção (11%) apresentaram ao menos um episódio de otorreia neste período, representando incidência de 0,11 (desvio padrão ±0,32) episódio/mês, enquanto no Grupo Não Proteção ocorreram 12 episódios (33%; p=0,045) e incidência de 0,33 (±0,48; p=0,02). Entre o 2º e o 13º meses pós-operatórios, não houve diferença entre os grupos. Sete pacientes do Grupo Proteção (20%) apresentaram ao menos um episódio de otorreia, representando incidência de 0,04 (±0,09) episódios/mês, enquanto no Grupo Não Proteção foram registrados sete episódios (22%; p=0,8) e incidência de 0,05 (±0,1; p=0,8). Conclusão Pacientes que realizaram a proteção auricular quando expostos à água apresentaram menor incidência de otorreia no primeiro mês pós-operatório do que aqueles que não a realizaram. A partir do segundo mês, não houve diferença entre os grupos.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Adolescent , Adult , Young Adult , Otitis Media, Suppurative/etiology , Otitis Media, Suppurative/prevention & control , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Water/adverse effects , Middle Ear Ventilation/adverse effects , Otitis Media, Suppurative/epidemiology , Postoperative Complications/epidemiology , Swimming , Time Factors , Baths/adverse effects , Brazil/epidemiology , Logistic Models , Incidence , Risk Factors , Treatment Outcome , Statistics, Nonparametric , Ear Protective Devices
4.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 707-709, 2017.
Article in Chinese | WPRIM | ID: wpr-510443

ABSTRACT

Objective To investigate the auditory performance of noise -exposed workers in a metal smelting factory,and to analyze the relationship between different noise -age,hearing protection and noise damage, and to provide the basis for the prevention and control of noise.Methods According to GBZ188 -2014 Occupational Health Surveillance Technical Specification,the pure tone audiometry test results of 438 workers in a special metal smelter in this city were analyzed statistically.Results The detection rate of hearing impairment was 25.6%.The incidence of hearing impairment in different occupational groups was statistically significant( 10 years 40.0%)(χ2 =15.10,P <0.01).The incidence of hearing loss was compared between the hearing protection with wearing earplugs group(the earplug group)and without wearing earplugs group (the control group),the difference was statistically significant(20.0% in the earplug group and 31.2% in the control group,χ2 =20.15,P <0.01),and the noise detection rate was significantly higher in the earplug group than in the control group(4% in the earplug group and 12% in the control group,χ2 =9.14,P <0.01).Conclusion Noise in the special metal smelting factory is more than that of the workers,so it is necessary to perfect the hearing protection measures as soon as possible.

5.
Rev. CEFAC ; 18(3): 667-676, tab, graf
Article in Portuguese | LILACS | ID: lil-787753

ABSTRACT

RESUMO: Objetivo: avaliar a efetividade do uso de equipamento de proteção individual auricular (protetor auricular) de inserção, do tipo espuma moldável, em trabalhadores expostos a ruído, verificando se a sua utilização sem e com orientação sobre o seu uso adequado, proporciona a vedação necessária para a prevenção de agravos auditivos e extra-auditivos. Métodos: trata-se de um estudo pré-experimental descritivo, de corte transversal que utilizou o método quantitativo para a análise dos dados. Foram avaliados 75 trabalhadores (150 orelhas), com exposição a ruído ocupacional de diferentes setores e funções de várias empresas ou trabalhadores autônomos. Todos foram submetidos à audiometria tonal em três momentos distintos: i) para obtenção do limiar auditivo; ii) utilizando protetor auricular do tipo espuma moldável sem orientação sobre o seu uso adequado somente com as instruções contidas na embalagem; iii) usando o protetor auricular após orientação do fonoaudiólogo avaliador. Resultados: a comparação entre os valores obtidos na avaliação audiométrica com a utilização do protetor auricular, sem e com orientação do profissional fonoaudiólogo, revelou um ganho estatisticamente significante somente no caso de readaptação do dispositivo no conduto auditivo. Conclusão: a comparação entre as respostas evidencia uma maior efetividade e atenuação do protetor auricular, do tipo espuma moldável, após orientação adequada do fonoaudiólogo.


ABSTRACT: Purpose: to evaluate the effectiveness of the use of equipment of individual hearing protection (auricular protector) of insertion in workers exposed to noise, checking if its use with and without orientation about its adequate use, provides the necessary seal in the hearing impairment and extra-hearing impairment prevention. Methods: it is a descriptive pre-experimental study, of cross-sectional, which used a quantitative method for the data analysis. 75 workers were evaluated (150 ears), with exposure to occupational noise from different sectors and functions of several companies or self-employed workers. All of them were submitted to tonal audiometry in three distinctive moments: i) for obtaining the hearing threshold; ii) using auricular protector of the moldable foam type without orientation about its adequate use; iii) using the auricular protector after the orientation of the phonoaudiologist that evaluates. Results: the comparison between the values obtained in the audiometric evaluation with the use of auricular protector, with and without orientation of the professional phonoaudiologist, revealed a statistically significant gain only in the case of rehabilitation of the device in the auditory canal. Conclusion: the comparison between the answers evidences a higher effectiveness and attenuation of the auricular protector of the moldable foam type, after the adequate orientation of the phonoaudiologist.

6.
CoDAS ; 27(6): 514-519, nov.-dez. 2015. tab
Article in English | LILACS | ID: lil-770517

ABSTRACT

ABSTRACT Purpose: To determine the efficacy of hearing protector insertion by comparing attenuation values measured by objective (MIRE) and subjective (REAT) methods in groups with and without training. Methods: The study included 80 male subjects assigned to experimental (with training) and control (without training) groups. The following procedures were performed: occupational history, objective and subjective assessment of hearing protectors. Only subjects in the experimental group received training and guidance on proper hearing protector insertion. Results: Attenuation values were significantly higher in the experimental group than in the control group at all frequencies (500, 1000, 2000, and 4000 Hz) investigated through the objective (MIRE) and subjective (REAT) methods. In addition, attenuation values in the control group were lower than those provided by the hearing protector manufacturer. Conclusion: Both objective and subjective attenuation tests demonstrated the efficacy of training on insertion of hearing protectors because the group that received training on proper hearing protection insertion exhibited higher attenuation values than the untrained group.


RESUMO Objetivo: Determinar a eficácia da colocação do protetor auditivo comparando os valores de atenuação obtidos pelos métodos objetivo (MIRE) e subjetivo (REAT) em grupos com e sem treinamento. Métodos: Participaram do estudo 80 indivíduos do sexo masculino, separados em grupo pesquisa (com treinamento) e controle (sem treinamento). Os procedimentos realizados foram: anamnese e avaliações objetiva e subjetiva do protetor auditivo. Apenas os indivíduos do grupo pesquisa receberam treinamento e orientações para colocar corretamente o protetor auditivo. Resultados: Os valores de atenuação no grupo pesquisa foram maiores com diferenças estatisticamente significantes em relação ao grupo controle em todas as frequências (500, 1000, 2000 e 4000 Hz) investigadas por meio dos métodos objetivo (MIRE) e subjetivo (REAT). Além disso, os valores de atenuação no grupo controle foram menores do que as previstas pelo fabricante do protetor auditivo. Conclusão: Ambos os métodos de avaliação da atenuação (objetivo e subjetivo) demonstraram a eficácia da colocação do protetor auditivo. Entretanto, o grupo que recebeu treinamento para colocação adequada do protetor auditivo apresentou valores de atenuação maiores do que o grupo sem treinamento.


Subject(s)
Adolescent , Adult , Humans , Male , Middle Aged , Young Adult , Ear Protective Devices , Inservice Training/methods , Noise, Occupational/prevention & control , Analysis of Variance , Auditory Threshold , Cross-Sectional Studies , Hearing Tests , Hearing Loss, Noise-Induced/prevention & control , Occupational Exposure/prevention & control , Program Evaluation , Reference Standards , Reproducibility of Results
7.
Article in English | LILACS | ID: biblio-962173

ABSTRACT

OBJECTIVE To analyze whether sociodemographic, occupational, and health-related data are associated with the use of hearing protection devices at work, according to gender. METHODS A cross-sectional study was conducted in 2006, using a random sample of 2,429 workers, aged between 18 and 65 years old, from residential sub-areas in Salvador, BA, Northeastern Brazil. Questionnaires were used to obtain sociodemographic, occupational, and health-related data. Workers who reported that they worked in places where they needed to shout in order to be heard were considered to be exposed to noise. Exposed workers were asked whether they used hearing protection devices, and if so, how frequently. Analyses were conducted according to gender, with estimates made about prevalence of the use of hearing protection devices, prevalence ratios, and their respective 95% confidence intervals. RESULTS Twelve percent (12.3%) of study subjects reported that they were exposed to noise while working. Prevalence of the use of hearing protection devices was 59.3% for men and 21.4% for women. Men from higher socioeconomic levels (PR = 1.47; 95%CI 1.14;1.90) and who had previous audiometric tests (PR = 1.47; 95%CI 1.15;1.88) were more likely to use hearing protection devices. For women, greater perceived safety was associated with the use of protection devices (PR = 2.92; 95%CI 1.34;6.34). This perception was specifically related to the presence of supervisors committed to safety (PR = 2.09; 95%CI 1.04;4.21), the existence of clear rules to prevent workplace injuries (PR = 2.81; 95%CI 1.41;5.59), and whether they were informed about workplace safety (PR = 2.42; 95%CI 1.23;4.76). CONCLUSIONS There is a gender bias regarding the use of hearing protection devices that is less favorable to women. The use of such devices among women is positively influenced by their perception of a safe workplace, suggesting that gender should be considered as a factor in hearing conservation programs.


OBJETIVO Analisar se dados sociodemográficos, ocupacionais e de saúde estão associados ao uso de equipamento de proteção auditiva no trabalho, segundo gênero. MÉTODOS Estudo transversal com amostra aleatória de 2.429 trabalhadores de 18 a 65 anos de subáreas de base domiciliar em Salvador, BA, no ano de 2006. Foram aplicados questionários para obtenção de dados sociodemográficos, ocupacionais e de saúde. Foram considerados expostos ao ruído aqueles que relataram trabalhar em local onde era necessário gritar para ser ouvido. Os trabalhadores expostos foram questionados sobre uso e regularidade do uso de equipamento de proteção auditiva. A análise foi conduzida por gênero, estimando-se a prevalência do uso do equipamento de proteção auditiva, razões de prevalência e os respectivos intervalos de 95% de confiança. RESULTADOS Entre os participantes do estudo, 12,3% referiram trabalhar expostos ao ruído. A prevalência do uso do equipamento de proteção auditiva foi 59,3% e 21,4%, para homens e mulheres, respectivamente. Entre os homens, maior nível socioeconômico (RP = 1,47; IC95% 1,14;1,90) e ter realizado audiometria (RP = 1,47; IC95% 1,15;1,88) foram fatores associados ao uso do equipamento. Entre as mulheres, a percepção de maior segurança associou-se ao uso do equipamento (RP = 2,92; IC95% 1,34;6,34). Essa percepção deveu-se, especialmente, à presença de supervisores comprometidos com a segurança (RP = 2,09; IC95% 1,04;4,21), à existência de regras claras para evitar acidentes de trabalho (RP = 2,81; IC95% 1,41;5,59) e ao recebimento de informações sobre segurança no trabalho (RP = 2,42; IC95% 1,23;4,76). CONCLUSÕES Há um viés de gênero em relação ao uso do equipamento de proteção auditiva menos favorável às mulheres em comparação com os homens. O uso do equipamento entre mulheres é influenciado positivamente pela percepção de um ambiente de trabalho seguro, sugerindo que o gênero precisa ser considerado nos programas de conservação auditiva.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Aged , Young Adult , Ear Protective Devices/statistics & numerical data , Hearing Loss, Noise-Induced/prevention & control , Noise, Occupational/prevention & control , Occupational Diseases/prevention & control , Perception , Socioeconomic Factors , Brazil , Sex Factors , Cross-Sectional Studies , Surveys and Questionnaires , Workplace , Hearing Tests , Middle Aged
8.
Rev. CEFAC ; 14(1): 65-78, jan.-fev. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-617180

ABSTRACT

OBJETIVO: validar a versão para língua portuguesa do questionário "Crenças e Atitudes sobre a Prevenção de Perdas Auditivas", desenvolvido pelo National Institute for Occupational Safety and Health in 1996. MÉTODO: a validação do questionário seguiu as seguintes etapas: tradução do idioma inglês para o português, pré-teste com um subgrupo de 10 trabalhadores, adaptação lingüística, revisão da equivalência gramatical e idiomática e processo inverso de tradução do português para o inglês, para verificar se houve descaracterização do questionário. Participaram do estudo 31 trabalhadores de uma indústria frigorífica, 17 do sexo masculino e 14 do sexo feminino, com idade média de 29 anos e 7 meses. As questões utilizadas foram medidas seguindo a escala de Likert com cinco graus, onde 1 - corresponde a "concordo totalmente" e 5 - "discordo totalmente". A análise fatorial objetivou explicar a ligação entre um conjunto de variáveis correlacionadas. Os trabalhadores responderam ao primeiro questionário (Versão A) e num prazo de 15 dias responderam ao segundo questionário (Versão B). RESULTADOS: a reprodutibilidade do instrumento foi demonstrada pelo índice geral de Alfa de Cronbach de 0, 8146 para o formulário A e 0, 8569 para o formulário B. As correlações foram significantes indicando a validade de construto e conteúdo da versão em Português Brasileiro para o seu uso com uma população trabalhadora. CONCLUSÕES: o questionário foi traduzido e adaptado para ser aplicado na população brasileira, denominado Crenças e Atitudes sobre a Prevenção de Perdas Auditivas, e servirá como instrumento na avaliação das atitudes e comportamento dos trabalhadores frente ao ruído e prevenção de perdas auditivas.


PURPOSE: to evaluate the Brazilian Portuguese version of the instrument "Beliefs and Attitudes on Hearing Loss Prevention", developed by the National Institute for Occupational Safety and Health in 1996. METHOD: the development of the Portuguese scale followed the following steps: translation from English into Brazilian Portuguese, pre-test with a group of 10 workers compared to the target population, linguistic adaptation, review of grammatical and idiomatic equivalence, and reverse translation into English in order to check that the instrument remained true to its original version. Following this elements, the Portuguese instrument was validated with the group of 31 workers. The participating workers came from a meat-packing company. Seventeen were males and 14 were females, and their mean age was 29 years and 7 months. The questions were constructed using a 5-point Likert scale where 1 meant "disagree completely" and 5 meant "agree completely." A factorial analysis was conducted in order to check construct validity of correlated questionnaire items. The participants responded to the first questionnaire (version A) and 15 days later responded to the second questionnaire (Version B). RESULTS: the validity of the entire instrument was demonstrated by a Cronbach's Alpha of 0.8146 for the version A of the instrument and 0.8569 for the Version B. The significant correlations among related questionnaire items indicate the validity of its format and content for the intended usage with a Brazilian Portuguese version with a population of workers. CONCLUSIONS: the questionnaire was translated and adapted to Brazilian Portuguese and will facilitate the evaluation of attitudes and beliefs of Brazilian-Portuguese speaking workers towards noise and hearing loss prevention.

9.
Braz. j. otorhinolaryngol. (Impr.) ; 76(4): 454-461, jul.-ago. 2010. tab
Article in Portuguese | LILACS | ID: lil-556876

ABSTRACT

Músicos de pop-rock apresentam risco de perda auditiva e outros efeitos associados à exposição à música amplificada. OBJETIVO: Avaliar o uso de protetores auditivos em músicos de bandas de pop-rock. Forma de Estudo: Coorte contemporânea. MATERIAL E MÉTODO: Estudo com 23 músicos de pop-rock, do sexo masculino, com idades entre 25 e 45 anos. Após a realização de audiometria tonal, imitância acústica, EOAET e EOAPD, os músicos receberam um protetor auditivo utilizado por três meses e, após esse período, preencheram a um questionário sobre a satisfação em relação ao uso. RESULTADOS: A prevalência de perdas auditivas foi de 21,7 por cento. As principais queixas durante o uso de protetor foram: voz abafada, pressão no ouvido, interferência na percepção dos sons de frequências altas, ao uso do protetor em tempo integral nas apresentações. Houve correlação positiva entre a percepção da diminuição do zumbido após o uso do protetor auditivo com as seguintes queixas: presença de zumbido após iniciar a profissão (p= 0,044), incômodo com a intensidade sonora em seu local de trabalho (p= 0,009) e intolerância a som forte (p= 0,029). CONCLUSÕES: Houve uma elevada prevalência de perdas auditivas e uma tendência favorável à aceitação do protetor auditivo na população estudada.


Pop-rock musicians are at risk of developing hearing loss and other symptoms related to amplified music. AIM: The aim of the present study was to assess the satisfaction provided by the use of hearing protection in pop-rock musicians. Study design: Contemporary cohort study. MATERIALS AND METHODS: A study of 23 male pop-rock musicians, aged between 25 to 45 years. After audiological evaluation (pure tone audiometry, middle ear analysis, TEOAE and DPOAE) hearing protective devices were provided to be used for three months. After that musicians answered a satisfaction assessment questionnaire. RESULTS: The prevalence of hearing loss was of 21.7 percent. The most common complaints about the hearing protectors were: autophonia, pressure in the ears, interference in high frequencies perception and full time use of the hearing protector during concerts. There was a positive correlation between a reduction in tinnitus after the use of the HPD with the following complaints: tinnitus after beginning the career (p= 0.044), discomfort with the sound intensity in the work place (p= 0.009) and intolerance to loud sound (p= 0.029). CONCLUSIONS: There was a high prevalence of hearing loss and a positive tendency towards the use of the ear protector device among the sample population.


Subject(s)
Adult , Humans , Male , Middle Aged , Ear Protective Devices , Hearing Loss, Noise-Induced/diagnosis , Music , Occupational Diseases/diagnosis , Tinnitus/diagnosis , Audiometry, Pure-Tone , Cohort Studies , Hearing Loss, Noise-Induced/prevention & control , Occupational Diseases/prevention & control , Surveys and Questionnaires , Time Factors , Tinnitus/prevention & control
10.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 699-704, 2008.
Article in Korean | WPRIM | ID: wpr-645328

ABSTRACT

BACKGROUND AND OBJECTIVES: One of the major occupational hazards of working in the military service is being subjected to intense impulse noise, hence acoustic trauma. Acute acoustic trauma is a preventable disease, but the effective treatment modality has not been established yet. Acute acoustic traumas caused by exposure to rifle gunshot noise are common in young Korean males in the military service because of conscription policy. Through the analysis of the clinical presentation of acoustic traumas caused by rifle gunshot noise, we suggest effective preventive modalities. SUBJECTS AND METHOD: 165 soldiers who had otologic symptoms after performing regular rifle gunshot exercise without any hearing protective measures were analyzed. They all had been tested with K2 rifle. History taking, physical examination, pure-tone audiometry, and impedence audiometry, temporal MRI, and Newmann's tinnitus inventory questionnaire survey were performed. RESULTS: Most common and annoying symptom was tinnitus. The average outcome of postexposure air conduction thresholds were 22.3dB HL in the affected ear and 11.8dB HL in the unaffected ear. There was no correlation between severity of tinnitus and severity of hearing loss. Asymmetry of hearing loss related to head position during gunshot was not found. This may be due to the fact that during the mass gunshot training, each patient can be influenced by the gunshot noise of the adjacent gunner's shooting. CONCLUSION: Widening the distance between firing lanes and providing bilateral hearing protective devices against acoustic trauma must be taken into serious consideration.


Subject(s)
Humans , Male , Acoustics , Audiometry , Audiometry, Pure-Tone , Ear , Ear Protective Devices , Fires , Head , Hearing , Hearing Loss , Hearing Loss, Noise-Induced , Military Personnel , Noise , Physical Examination , Surveys and Questionnaires , Tinnitus
11.
São Paulo med. j ; 125(6): 359-361, Nov. 2007. graf
Article in English | LILACS | ID: lil-476100

ABSTRACT

CONTEXT AND OBJECTIVE: Noise-induced hearing loss can only be prevented by eliminating or lowering noise exposure levels. When the source of the noise cannot be eliminated, workers have to rely on hearing protection equipment. The aim here was to summarize the evidence for the effectiveness of interventions to enhance the wearing of hearing protection among workers exposed to noise in the workplace. DATA SOURCE: Studies with random assignment were identified by an electronic search of the medical literature up to 2005. Data were double-entered into the Review Manager software, version 4.2.5. DATA SYNTHESIS: Two studies were found. A computer-based intervention tailored to individual workers’ risks and lasting 30 minutes was not found to be more effective than a video providing general information for workers. A second randomized controlled trial evaluated the effect of a four-year school-based hearing loss prevention program among schoolchildren working on their parents’ farms. The intervention group was twice as likely to wear some kind of hearing protection as was the control group (which received only minimal intervention). REVIEWERS’ CONCLUSIONS: The limited evidence does not show whether tailored interventions are more or less effective than general interventions among workers, 80 percent of whom already use hearing protection. Long-lasting school-based interventions may increase the use of hearing protection substantially. Better interventions to enhance the use of hearing protection need to be developed and evaluated in order to increase the prevention of noise-induced hearing loss among workers.


CONTEXTO E OBJETIVO: Perda auditiva induzida por ruído pode apenas ser prevenida eliminando ou diminuindo os níveis de exposição sonora. Quando a fonte do ruído não pode ser eliminada, trabalhadores devem utilizar os equipamentos de proteção auditiva. O objetivo foi sumarizar as evidências sobre efetividade das intervenções para aumentar o uso de protetores auriculares entre trabalhadores expostos a ruídos. ESTRATÉGIA DE BUSCA: Estudos randomizados foram identificados por busca eletrônica na literatura médica até 2005. Os dados foram checados duplamente e inseridos no software Review Manager software, versão 4.2.5. RESULTADO PRINCIPAL: Dois estudos foram encontrados. Uma intervenção padronizada por computador em relação ao risco de um trabalhador individual durou 30 minutos e não foi mais efetiva do que um vídeo fornecendo informações gerais entre os trabalhadores. Um segundo ensaio clínico randomizado avaliou os efeitos de um programa de prevenção auditiva de quatro anos em uma escola onde jovens trabalhavam nas fazendas de seus pais. O grupo de intervenção foi duas vezes mais provável de usar algum tipo de protetor auricular do que o grupo controle, que recebeu mínima intervenção. CONCLUSÃO DOS REVISORES: Limitada evidência não demonstrou quando as intervenções padronizadas são mais ou menos efetivas do que intervenções gerais em trabalhadores, 80 por cento deles já utilizavam o protetor auricular. Intervenções longas em escolas podem aumentar substancialmente o uso de protetores auriculares. Melhores intervenções para aumentar o uso de Equipamentos de Proteção Individual (EPIs) devem ser desenvolvidas e avaliadas com intuito de aumentar a prevenção de perda auditiva induzida por ruído em trabalhadores.


Subject(s)
Humans , Ear Protective Devices/statistics & numerical data , Health Education , Health Promotion , Hearing Loss, Noise-Induced/prevention & control , Noise, Occupational/adverse effects , Evidence-Based Medicine , Hearing Tests , Occupational Diseases/prevention & control , Randomized Controlled Trials as Topic , Workplace
12.
Cad. saúde colet., (Rio J.) ; 15(1)jan.-mar. 2007.
Article in English | LILACS | ID: lil-482700

ABSTRACT

As atividades de tiro, de fuzil e de artilharia, promovem níveis elevados de ruído, que podem provocar alterações no sistema auditivo. O objetivo deste estudo foi medir o nível de ruído a que os militares estão expostos durante o tiro de fuzil e identificar possíveis motivos para que o militar não utilize a proteção auditiva durante essa atividade e no tiro de artilharia. O presente estudo caracteriza-se como transversal. Utilizou-se (a) questionário auto-aplicável, com o objetivo de mapear o perfil dos informantes e os motivos que os levavam a utilizar ou não a proteção auditiva nas atividades de tiro; (b) medição do nível de pressão sonora, para dimensionar o risco ocupacional da atividade de tiro; (c) observação sistemática, para mapear o processo de trabalho e (d) entrevista semi-estruturada, para verificar outras percepções de risco relacionados com a atividade de tiro, além da relativa à audição. Durante as atividades de tiro de fuzil e de artilharia, os militares estão expostos a um nível de pressão sonora mínimo de 147 dB, com indícios da possibilidade de que esse valor possa atingir 188 dB. Foi constatado que, no tiro de fuzil, 44 militares (55,7 por cento) não utilizam proteção auditiva e, no tiro de artilharia, esse número aumentou para 65 militares (82,3 por cento). Os fatores que contribuem para que os militares negligenciem sua segurança auditiva nas atividades de tiro são: a falta de informação quanto ao real risco da exposição aos ruídos dos tiros; a falta da disponibilidade do equipamento de proteção auditiva no local de trabalho; e a falta de treinamento, orientação e fiscalização no uso de equipamento de proteção individual por parte dos responsáveis por essas atividades.


Subject(s)
Humans , Ear Protective Devices , Military Personnel , Noise, Occupational , Occupational Health , Occupational Risks , Brazil/epidemiology , Cross-Sectional Studies
13.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 887-891, 2006.
Article in Korean | WPRIM | ID: wpr-647372

ABSTRACT

BACKGROUND AND OBJECTIVES: Noise induced hearing loss (NIHL) is a preventive disease and yet the effective treatment modality has not been established. Acute acoustic traumas caused by an exposure to gunshot noise are common in young Korean males in the military service. Considering the significant lack of awareness on this serious issue as well as the absence of proper protection gears, an in-depth analysis is desperately needed. SUBJECTS AND METHOD: 3,650 soldiers performed a regular gunshot exercise without any hearing protective measures. Out of 3,650 soldiers, 8 patients with hearing impairment after the regular gunfire visited aeromedical squadron. They were all right-handed males: 7 had been tested with K-2 rifle and 1 had been tested with K-5 revolver. History taking, physical examination, pure-tone audiometry, and impedence audiometry were performed. In the next round of gunshot practice, all soldiers performed gunfire with unilateral hearing protection. RESULTS: The average outcome of postexposure air conduction thresholds were 6.5 dB in the right ear and 33.1 dB in left ear. After medical treatment, hearing impairment was much improved ; however, tinnitus was not diminished. In the next round of gunshot practice, the supplement of unilateral earplug protection proved its effectiveness on acoustic trauma caused by gunfire noise. CONCLUSION: Asymmetry of hearing loss was related to head position during gunfire. Unilateral hearing protection device was enough to protect hearing from acoustic trauma caused by gunshot. At the same time, it can effectively prevent a potential firearm accident that can be caused by trainees' mishearing the instruction of firearm instructor if both earplugs are worn. Thus, providing unilateral earplug protection against acoustic trauma must be taken into serious consideration.


Subject(s)
Humans , Male , Audiometry , Audiometry, Pure-Tone , Ear , Ear Protective Devices , Head , Hearing Loss , Hearing Loss, Noise-Induced , Hearing , Military Personnel , Noise , Physical Examination , Tinnitus
SELECTION OF CITATIONS
SEARCH DETAIL