Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Braz. dent. sci ; 23(2): 1-8, 2020. ilus
Article in English | LILACS, BBO | ID: biblio-1095886

ABSTRACT

Objective: This work aims to use new spectroscopic and radiographic methods to study the dental hard tissue erosion and abfraction, as these lesions are actually quite difficult to be diagnosed in clinical practice. Material and Methods: This in vivo study was conducted on 60 patients with early erosion and 60 patients with abfraction at the cervical area by means of laser-induced fluorescence (LIF) and multilayer spiral computed tomography (MSCT). Results: In comparative dental hard tissues studies LIF spectra from intact and affected areas, it was noted multidirectional fluorescence intensity dependence between areas affected by abfraction and intact areas. MSCT technique allowed assessing the degree of damaged areas, especially at deeper stages. Conclusion: Although LIF and MSCT methods presented limitations, it was shown their effectiveness in the diagnosis of abfraction and erosion by detecting changes in the morphological structure as well as in the chemical and mineral composition of affected dental hard tissues. So LIF and MSCT methods can be successfully used in order to develop new medical devices which will provide most accurate clinical diagnose of different stages of dental erosion and abfraction.(AU)


Objetivo: Este trabalho tem como objetivo utilizar novos métodos espectroscópicos e radiográficos para estudar a erosão e a abração do tecido duro dentário, pois essas lesões são realmente bastante difíceis de serem diagnosticadas na prática clínica. Material e Métodos: Este estudo in vivo foi realizado em 120 pacientes com erosão e abração precoces na área cervical por meio de fluorescência induzida por laser (LIF) e tomografia computadorizada em espiral multicamada (MSCT). Resultados: Em estudos comparativos espectros de LIF, de tecidos duros dentais intactos e afetados, observouse dependência da intensidade da fluorescência multidirecional entre as áreas afetadas pela abração e as áreas intactas. A técnica MSCT permitiu avaliar o grau de áreas danificadas, principalmente em estágios mais profundos. Conclusão: Embora os métodos LIF e MSCT tenham apresentado limitações, foi demonstrada sua eficácia no diagnóstico de abração e erosão, detectando alterações na estrutura morfológica e na composição química e mineral dos tecidos duros afetados. Portanto, os métodos LIF e MSCT podem ser utilizados com sucesso, a fim de desenvolver novos dispositivos médicos que fornecerão um diagnóstico clínico mais preciso de diferentes estágios de erosão e abração dentária.(AU)


Subject(s)
Humans , Spectrometry, Fluorescence , Tooth Erosion , Tooth Demineralization , Tomography, Spiral Computed
2.
Bauru; s.n; 2017. 143 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-880165

ABSTRACT

A adição de corantes fluorescentes a adesivos odontológicos possibilita a investigação da distribuição espacial desses materiais na interface dente-restauração, utilizando-se a microscopia confocal de varredura a laser (MCVL). A literatura indica falta de padronização na aplicação de agentes fluorescentes com tal finalidade. Esse estudo sistematizou estratégias para a adição de rodamina B (RB) e fluoresceína sódica (FS) a um sistema adesivo convencional de três passos, Adper Scotchbond Multi-Purpose (MP), e um autocondicionante de dois passos, Clearfil SE Bond (SE), considerados "padrão-ouro" na Odontologia. Os objetivos principais foram (a) determinar a menor faixa de concentrações de RB e FS necessária para produzir imagens satisfatórias da interface dentina-adesivo e (b) avaliar o efeito da adição desses corantes sobre algumas propriedades das resinas. Os adesivos foram marcados com RB ou FS em concentrações decrescentes (0,5, 0,1, 0,02 e 0,004 mg/mL) por meio de um método de dispersão semidireto. O comportamento fotofísico/ fluorescente dos adesivos marcados foi investigado por espectroscopia de fotoluminescência e MCVL. Paralelamente, avaliaram-se os adesivos quanto ao grau de conversão (GC) e ao ângulo de contato (AC). Tanto os resultados de GC como os de AC foram submetidos à análise de variância com dois fatores (adesivo e tratamento) com α = 0,05, seguida de teste post-hoc de Tukey. Os máximos comprimentos de onda de emissão e de excitação da RB e da FS foram influenciados pelo meio polimérico e pela concentração de corante de modo geral. A MCVL preliminar de amostras de adesivo polimerizado, realizada sob condições experimentais padronizadas, mostrou que o comportamento fluorescente da RB em MP e SE foi muito semelhante na mesma concentração de corante, mas o mesmo não pôde ser dito do comportamento da FS, que foi notavelmente inferior no adesivo autocondicionante, SE, na concentração mais alta. Em dentina, os adesivos preparados com RB nas concentrações-alvo de 0,1 e 0,02 mg/mL apresentaram fluorescência ótima; já aqueles preparados com 0,004 mg/mL produziram fraco sinal. Adesivos preparados com FS a 0,5 mg/mL apresentaram ótima fluorescência na interface de adesão, enquanto que concentração menor desse corante não produziu sinal suficiente. Padrões morfológicos aparentemente atípicos foram observados na interface de adesão, quando da associação do adesivo SE com o corante FS. A adição de RB e FS nas quatro concentrações indicadas aos adesivos MP e SE não afetou o GC nem o AC em comparação com os grupos de controle correspondentes. Em suma, a RB mostra-se um corante mais versátil que a FS na avaliação morfológica das interfaces dentina-MP e dentina-SE via MCVL. A menor faixa de concentrações de RB nos adesivos MP e SE, na qual é possível produzir imagens satisfatórias das interfaces, situa-se entre 0,1­0,02 mg/mL. Já o corante FS deve ser adicionado a esses adesivos a pelo menos 0,5 mg/mL para produzir níveis de fluorescência satisfatórios na interface de adesão. A não ocorrência de efeitos deletérios sobre a polimerização e a molhabilidade das resinas estabelece uma margem de segurança para a incorporação desses agentes fluorescentes (em concentração ≤ 0,5 mg/mL) nesses sistemas monoméricos.(AU)


The addition of fluorescent dyes to dental adhesives makes it possible to investigate the spatial distribution of such resin-based materials in the tooth-restoration interface, using confocal laser scanning microscopy (CLSM). Literature indicates a lack of standardization on the application of fluorescent agents for this purpose. This work presents strategies for adding rhodamine B (RB) and fluorescein sodium salt (FS) to a three-step etch-and-rinse adhesive system, Adper Scotchbond Multi-Purpose (MP), and a two-step self-etching one, Clearfil SE Bond (SE), both regarded as "gold standard" in restorative dentistry. The main objectives were (a) to determine the lowest range of RB and FS concentrations required to produce suitable images of the dentin-adhesive interface via CLSM and (b) to investigate potential effects of addition of these dyes on some resin properties. The adhesives were labeled with RB or FS at decreasing concentrations (0.5, 0.1, 0.02 and 0.004 mg/mL) by means of a semi-direct dispersion method. The photophysical/fluorescent behavior of the labeled resins was investigated by photoluminescence spectroscopy and by CLSM. The adhesives were also investigated with regards to the degree of conversion (DC) and contact angle (CA). A two-way ANOVA of "adhesive" and "treatment" was conducted on DC and CA separately, followed by Tukey's test. The maximum emission and excitation wavelengths of RB and FS were influenced by the host polymer and the dye concentration in general. The preliminary CLSM of cured adhesive samples, performed with standardized settings, showed that the fluorescent behavior of RB in MP and SE was very similar in the same dye concentration, unlike the behavior of FS, which was lower in the self-etching adhesive for the highest dye concentration. In dentin, the adhesives prepared with RB at the target concentrations of 0.1 and 0.02 mg/mL presented optimal fluorescence; those with 0.004 mg/mL produced poor signal. Adhesives prepared with FS at 0.5 mg/mL presented optimal fluorescence at the bonding interface, whereas lower concentrations of FS did not produce sufficient signal. Atypical morphological features were observed at the bonding interface, when adhesive SE was used with FS. The addition of RB and FS at the four decreasing concentrations to adhesives MP and SE did not affect DC or CA compared to the corresponding controls. In short, RB is more versatile than FS for the morphological characterization of dentin-MP and dentin-SE interfaces via MCVL. The lowest range of RB concentrations in adhesives MP and SE that can produce suitable images of the bonding interface lies between 0.1­0.02 mg/mL. The dye FS should be added to these adhesives at 0.5 mg/mL at least to produce satisfactory fluorescence levels at the bonding interface. Since negative effects on polymerization and wettability of the resins were not observed, the use of RB and FS (in concentration ≤ 0.5 mg/mL) together with MP and SE should be reliable in terms of resin properties.(AU)


Subject(s)
Fluorescein/chemistry , Fluorescent Dyes/chemistry , Resin Cements/chemistry , Rhodamines/chemistry , Analysis of Variance , Ethanol/chemistry , Microscopy, Confocal , Reference Values , Reproducibility of Results , Self-Curing of Dental Resins/methods , Spectrometry, Fluorescence , Spectrophotometry, Infrared
3.
Vitae (Medellín) ; 24(2): 113-123, 2017. Ilustraciones
Article in English | LILACS, COLNAL | ID: biblio-994663

ABSTRACT

Background: Several investigations report to rosemary as a plant rich in bioactive components with antioxidant potential, in this work, a rosemary extract was obtained that combined with ascorbyl palmitate provides a synergistic protection to a high fat diet (palm olein). Objectives: The objective of this study was to evaluate the effect of the addition of two extracts of rosemary (Rosmarinus officinalis): AP10R and AP30R at three concentrations of 1000, 1500 and 2000 ppm, on the oxidative stability of palm oil subjected to accelerated oxidation conditions and in a frying process. Methods: Lipid peroxidation of palm olein with and without antioxidants was monitored by measuring the concentration of hydroperoxides and total polar compounds; the thermal stability of the phenolic compounds in the oil was evaluated by fluorescence spectroscopy. Results: The AP10R extract at 2000 ppm inhibited olein oxidation by 30% and 60% in terms of total hydroperoxide and polar concentrations, respectively. The AP30 extract at 2000 ppm had similar inhibition behaviors with values of 27% of total hydroperoxides and 54% by total polar compounds in a time from 20 to 25 h. Conclusions: The results indicated that heating reduces the concentration of polyphenols; this decrease was more evident in olein without antioxidants, reflecting the effect of the polyphenols of rosemary extract on the thermal stability of palm olein.


Antecedentes: Diversas investigaciones reportan al romero como una planta rica en componentes bioactivos con potencial antioxidante, en este trabajo, se obtuvo un extracto de romero que combinado con ascorbil palmitato brinda una protección sinérgica a un sistema alimenticio con alto contenido graso (oleína de palma). Objetivos: El objetivo de este estudio fue evaluar el efecto de la adición de dos extractos de romero (Rosmarinus officinalis): AP10R y AP30R a tres concentraciones de 1000, 1500 y 2000 ppm, sobre la estabilidad oxidativa del aceite de palma sometido a condiciones de oxidación acelerada y en un proceso de fritura. Métodos: La peroxidación lipídica de la oleína de palma con y sin antioxidantes fue monitoreada midiendo la concentración de hidroperóxidos y los compuestos polares totales; la estabilidad térmica de los compuestos fenólicos en el aceite se evaluó por espectroscopia de fluorescencia. Resultados: El extracto AP10R a 2000 ppm inhibió la oxidación de oleína en 30% y 60% en términos de la concentración de hidroperóxidos y polares totales, respectivamente. El extracto AP30 a 2000 ppm tuvo comportamientos similares de inhibición con valores de 27% para hidroperóxidos y 54% para el contenido de fenoles totales en un tiempo de 20 a 25 h. Conclusiones: Los resultados indicaron que el calentamiento disminuye la concentración de polifenoles; esta disminución fue más evidente en la oleína sin antioxidantes, reflejando el efecto de los polifenoles del extracto de romero sobre la estabilidad térmica de la oleína de palma.


Subject(s)
Humans , Palmitates , Spectrometry, Fluorescence , Palm Oil , Antioxidants
4.
Campinas; s.n; 2005. 99 p. ilus, graf.
Thesis in Portuguese | LILACS | ID: lil-604039

ABSTRACT

O fotodiagnóstico ou diagnóstico por fluorescência é um método complementar ao exame anátomo-patológico para detectar alterações morfológicas dos tecidos biológicos. A presente tese, apresentada segundo o formato alternativo estabelecido pela Comissão de pós-graduação da Unicamp, consta de três artigos e teve por objetivos: (1) estudar o efeito fotodinâmico, principalmente sob o ponto de vista diagnóstico, revendo a literatura sobre sua aplicação na cavidade bucal; (2) analisar através de estudo experimental em cães, a fluorescência nativa da mucosa oral avaliando a relação da mesma com diferentes sítios e estruturas; (3) desenvolver e validar um protótipo de fonte de luz e um método para estimulação e captação das fluorescências nativas em cavidade bucal de humanos; (4) avaliar os espectros de fluorescência assim obtidos , no sentido de determinar um padrão de fluorescência para mucosa oral normal. Para a elaboração desta tese foram utilizados 20 cães e 2 grupos de estudo compostos por 50 e 100 adultos normais, respectivamente. A revisão de literatura demonstrou que, embora exista grande quantidade de estudos sobre a fluorescência nativa, poucos se referem ao tecido normal, sem alterações patológicas. O projeto piloto (Capítulo 1) teve como objetivo principal estudar a fluorescência nativa produzida por radiação ultravioleta nos tecidos...


Photodiagnosis or Fluorescence Diagnosis is a complementary method to detect morphological alterations in biological tissues. The present thesis is composed of three papers and have the following objectives: (1) to study the photodynamic effect and its applications, mainly from diagnostic view point, reviewing the literature about its application in the buccal cavity ; (2) to analyze, through experimental study in dogs, the native fluorescence of the oral mucosa in relation to different sites and structures; (3) to developed and validate a prototype used to stimulate and detect native fluorescence in humans oral mucosa; (4) to analyze the obtained spectra with the objective to determine patterns of fluorescence for normal mucosa. The literature review comproved that despite the large amount of researches on native fluorescence, very few concerns to normal tissue and its morphological or physiological alterations. The three studied groups for this thesis were composed of 20 adults? mongrel dogs and, for the human study we selected 50 and 100 healthy volunteers, respectively. A pilot study was necessary to understand the fluorescent emissions of mucosal tissue under ultraviolet stimulation in order to develop the necessary methodology which was used with the animal model (Chapter I). With the obtained results and based on the literature review was possible to develop the prototype device used to study the native fluorescence of buccal cavity, in a group of 50 volunteers. This prototype is composed by three diodes (LEDs), emitting in ultraviolet region (410 nm) coupled to an optical fiber and connected to a plug-in spectrometer. The results of this preliminary work demonstrate that the fluorescence spectra shows significantly differences according to the various sites of the oral mucosa (Chapter II). Chapter III comprehends a more detailed study developed...


Subject(s)
Animals , Dogs , Fluorescence , Mouth Mucosa , Mouth Mucosa/cytology , Photochemotherapy , Mouth/anatomy & histology , Spectrometry, Fluorescence
SELECTION OF CITATIONS
SEARCH DETAIL