China Pharmacy ; (12): 2989-2990,2991, 2015.
Article in Chinese | WPRIM | ID: wpr-605077

ABSTRACT

OBJECTIVE:To establish a method for content determination of phosphatidylcholine in eustachian tube lavage fluid of patients with secretory otitis media. METHODS:HPLC was used. The samples were pretreated by liquid-liquid extraction. It was performed on the column of Hypersil CN with mobile phase of acetoneitril-methanol-phosphoric acid (100∶10∶0.6,V/V/V)at the flow rate of 1.8 ml/min,the detection wavelength was 205 nm,temperature was 30 ℃ and volume was 20 μl. RESULTS:The lin-ear range of phosphatidylcholine was 11.99-119.9 μg/ml(r=0.999 6);RSDs of precision tests of intra-day and inter-day were no more than 15%;average recovery was 97.54%(RSD=9.36%,n=9);the average content of phosphatidylcholine in eustachian tube lavage fluid of patients was(24.43±3.61)μg/ml. CONCLUSIONS:The method is simple and accurate,and can be used for the content determination of phosphatidylcholine in eustachian tube lavage fluid of patients with secretory otitis media.