Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 59
Filter
1.
RGO (Porto Alegre) ; 71: e20230006, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1431161

ABSTRACT

ABSTRACT The use of removable partial dentures is considered a common and inexpensive treatment option to rehabilitate edentulous areas. The aim of this study was to evaluate the effect of different materials for provisional removable partial dentures, an in vitro study on surface roughness and fracture resistance. Thermopolymerizable acrylic resin and thermoplastic resin specimens with dimensions of 10 x 10 x 2 mm (blocks) (n=10) and with dimensions of 65 x 20 x 3 mm (bars) (n=10 were analyzed for their surface roughness (Ra) and three-point flexural strength test. All specimens were subjected to oven aging for 60 days at 37°C±0.5°C in distilled water. The statistical analysis was performed with a significance level of 5%, and the surface roughness data were submitted to the Two-way Anova statistical test (P < 0.05) and the mechanical strength data were subjected to One-way Anova statistical test (P < 0.05). For roughness, the factor resin type (P = 0.000) and the factor aging (P = 0.000) were statically significant, as well as showing interaction (P = 0.228). The Thermopolymerizable acrylic resin had the lowest mean roughness values compared to the thermoplastic resin and showed no statistical difference after aging. The same scenario was repeated for flexural strength values; Thermopolymerizable acrylic resin was statistically superior to thermoplastic resin (P = 0.000). Thermopolymerized acrylic resin showed lower surface roughness values and higher flexural strength values compared to thermoplastic resin.


RESUMO O uso de próteses parciais removíveis é considerado uma opção de tratamento comum e de baixo custo para reabilitar áreas edêntulas. O objetivo deste estudo foi avaliar o efeito de diferentes materiais para próteses parciais removíveis provisórias, um estudo in vitro sobre rugosidade superficial e resistência à fratura. Espécimes de resina acrílica termopolimerizável e de resina termoplástica com dimensões de 10 x 10 x 2 mm (blocos) (n = 10) e de 65 x 20 x 3 mm (barras) (n = 10) foram analisados em rugosidade superficial média (Ra) e teste de resistência à flexão de três pontos. Todos os espécimes foram submetidos ao envelhecimento em estufa por 60 dias a 37 ° C ± 0,5 ° C em água destilada. A análise estatística se deu com nível de significância de 5%, e os dados de rugosidade superficial foram submetidos ao teste estatístico Anova dois fatores (P <0,05) e os dados de resistência mecânica foram submetidos ao teste estatístico Anova um fator (P <0,05). Para rugosidade, o fator tipo resina (P = 0,000) e o fator envelhecimento (P = 0,000) foram estatisticamente significantes, além de apresentar interação (P = 0,228). A resina acrílica termopolimerizável apresentou menores valores médios de rugosidade em relação à resina termoplástica e não apresentou diferença estatística após envelhecimento. O mesmo cenário foi repetido para valores de resistência à flexão; a resina acrílica termopolimerizável foi estatisticamente superior à resina termoplástica (P = 0,000). A resina acrílica termopolimerizada apresentou menores valores de rugosidade superficial e maiores valores de resistência à flexão em relação à resina termoplástica.

2.
RGO (Porto Alegre) ; 71: e20230050, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1514645

ABSTRACT

ABSTRACT Objectives: The objective was to evaluate the longevity of ceramic restorative materials in the manufacture of endocrown restorations, through an in vitro study on surface roughness and mechanical strength. Methods: Three restorative materials were evaluated and assigned to experimental groups (n=10 disc specimens): Leucite Reinforced Ceramic, Lithium Disilicate and Nanoceramic Resin. These restorative materials were evaluated for surface before and after aging (n=02 specimens) under a stereomicroscope. The specimens were submitted to the average surface roughness test (Ra) (n=10) in a contact roughness meter before and after aging. As well as the biaxial flexural strength test (n=10), after aging, up to a test speed of 0.5 mm/min. Aging was carried out in a thermocycler, with 5,000 cycles with baths of 5 °C ± 1 ° and 55 °C ± 1 °. Fragments after fracture were observed under a stereomicroscope. The data obtained were tabulated and analyzed using the Minitab statistical program. Results: The surfaces of the specimens do not show changes between the restorative materials and also in relation to aging. For the roughness data, the restorative material factors (p=0.867) and aging (p=0.321) were not statistically significant. The DIS group presented the highest values of fracture resistance (p=0.000), in relation to the LEU and REN groups, which were statistically similar. The same statistical pattern was identified for post-fracture fragment data (p=0.030). Conclusions: The aging factors and restorative material do not interfere with the surface roughness performance. However, the mechanical performance and number of fragments after fracture is affected by the restorative material.


RESUMO Objetivos: Objetivou-se avaliar a longevidade de materiais restauradores cerâmicos na confecção de restaurações endocrowns, através de um estudo in vitro sobre rugosidade superficial e resistência mecânica. Métodos: Três materiais restauradores foram avaliados e distribuídos em grupos experimentais (n=10 espécimes em disco): Cerâmica Reforçada por Leucita, Dissilicato de Lítio e Resina Nanocerâmica. Estes materiais restauradores foram avaliados quanto a superfície antes e após ao envelhecimento (N=2 espécimes) em estereomicroscópio. Os espécimes foram submetidos ao ensaio de rugosidade superficial média (Ra) (N=10) em rugosímetro de contato antes e após o envelhecimento. Como também, ao teste de resistência à flexão biaxial (N=10), após envelhecimento, em uma velocidade de ensaio de 0,5 mm/min. O envelhecimento foi realizado uma termocicladora, sendo 5.000 ciclos com banhos de 5 °C ± 1° e 55 °C ± 1°. Os fragmentos após fratura foram observados em estereomicroscópio. Os dados obtidos foram tabulados e analisados no programa estatístico Minitab. Resultados: As superfícies dos espécimes não mostram alterações entre os materiais restauradores e também em relação ao envelhecimento. Para os dados de rugosidade, os fatores materiais restauradores (p=0,867) e envelhecimento (p=0,321) não foram estatisticamente significativos. O grupo DIS apresentou os maiores valores de resistência à fratura (p=0,000), em relação aos grupos LEU e REN que foram estatisticamente semelhantes. O mesmo padrão estatístico foi identificado para os dados de fragmentos após a fratura (p=0,030). Conclusão: Os fatores envelhecimento e material restaurador não interferem quanto a performance da rugosidade superficial. No entanto, o desempenho mecânico e número de fragmentos após a fratura é afetado pelo material restaurador.

3.
Braz. dent. sci ; 26(4): 1-8, 2023. ilus, tab
Article in English | BBO, LILACS | ID: biblio-1512140

ABSTRACT

Objective: To evaluate the biaxial flexural strength (BFS) of lithium disilicate (L), cemented on different substrates (epoxy resin - E and metal - M) with dual-cure resin cement (Rc) and zinc phosphate cement (Zc), not aged, thermally aged (TC) or thermo-mechanical aged (TC/MC). Material and Methods: Disks of L, E, and M were fabricated, and the cementation was performed according to the following groups: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Ten samples from each described group were tested in BFS, ten more samples were subjected to TC (1×104 cycles between 5 ºC and 55 ºC water), and the last 10 samples were subjected to TC/MC (MC: 1.2×106 cycles, 50 N, 3.8 Hz). The BFS test was performed and scanning electron microscopy (SEM) was performed to evaluate the failure mode. The effect of the cementation strategy (cement/substrate) was compared in each aging method and the effect of the aging method was evaluated for each cementation strategy by one-way ANOVA and Tukey post-hoc test (α=0.05). Results: The strength values were highest to M (237.8 ~ 463.9 MPa), in comparison to the E (41.03 ~ 66.76 MPa), despite aging and luting agent. Flexural strength data decreased after TC and TC/MC in groups cemented with Zc, but was stable when cemented with Rc. SEM analysis indicated that failure origins were located at the tensile surface of the L. Conclusion: Lithium disilicate discs cemented to the metallic substrate presented the highest biaxial flexural strength. The cementation with dual-cure resin cement did not decrease BFS after aging (AU)


Objetivo: Avaliar a resistência à flexão biaxial (BFS) do dissilicato de lítio (L), cimentado sobre diferentes substratos (resina epóxi - E e metal - M) com cimento resinoso dual (Rc) e cimento de fosfato de zinco (Zc), não envelhecido, submetido ao envelhecido térmico (TC) ou ao envelhecido térmico-mecânico (TC/MC). Material e Métodos: Foram confeccionados discos de L, E e M, e a cimentação foi realizada de acordo com os seguintes grupos: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Dez amostras de cada grupo descrito foram testadas em BFS, mais dez amostras foram submetidas à TC (1×104 ciclos de imersão em água entre 5 ºC e 55 ºC), e as últimas 10 amostras foram submetidas à TC/MC (MC: 1.2 ×106 ciclos, 50 N, 3.8 Hz). Foram realizados os testes de BFS e a microscopia eletrônica de varredura (MEV) para avaliar o modo de falha. O efeito da estratégia de cimentação (cimento/substrato) foi comparado em cada método de envelhecimento e o efeito do método de envelhecimento foi avaliado para cada estratégia de cimentação por ANOVA a um fator e teste post-hoc de Tukey (α=0,05). Resultados: Os valores de resistência foram maiores para M (237.8 ~ 463.9 MPa), em comparação com E (41.03 ~ 66.76 MPa), independentemente do envelhecimento e do agente cimentante utilizado. Os dados de resistência à flexão diminuíram após TC e TC/MC nos grupos cimentados com Zc, mas se mantiveram estáveis quando cimentados com Rc. A análise MEV indicou que a origem das falhas estava localizada na superfície de tração do L. Conclusão: Os discos de dissilicato de lítio cimentados ao substrato metálico apresentaram maior resistência à flexão biaxial. A cimentação com cimento resinoso dual não diminuiu o BFS após o envelhecimento (AU)


Subject(s)
Aging , Cementation , Flexural Strength
4.
J. health sci. (Londrina) ; 23(3): 185-190, 20210920.
Article in English | LILACS-Express | LILACS | ID: biblio-1292749

ABSTRACT

This research aimed to evaluate the bond strength by micro tensile strength (µTBS), elastic modulus (EM) and flexural strength (FS) by the three-point test using three types of composite resins: Charisma Diamond, Filtek Z350 and Tetric N-Ceram Bulk Fill; and three adhesion techniques: adhesive, silane, silane and adhesive. The combinations of each resin with the adhesive technique resulted in nine groups (n = 12). Initially, with the composites, EM and FS tests were performed. Sequentially, each fragment was repaired with the different adhesive systems. All samples were subjected to µTBS testing on a universal assay machine. Data were subjected to the normality test and the parametric ANOVA test. Charisma resin showed the highest values in EM and RF compared to the other composite resins (p <0.05). The highest µTBS value was for silane + adhesive repaired Charisma resin. The lowest µTBS values were in Bulk Fill resin, regardless of adhesive system. The EM and FS results showed that Filtek Z350 resins had the best results, while bulk fill resins had lower results. It was concluded that Charisma and Filtek Z350 resins presented better results. However, in the bulk fill group, the lowest mean values of µTBS, FS and EM were obtained, as well as the lowest value in EM. (AU)


Esta pesquisa teve como objetivo avaliar a resistência de união (RU) por resistência à microtração, módulo de elasticidade (ME) e resistência à flexão (RF) pelo teste de três pontos, utilizando três tipos de resinas compostas: Charisma Diamond, Filtek Z350 e Tetric N-Ceram Bulk Fill; e três técnicas de adesão: adesivo, silano, silano e adesivo. As combinações de cada resina com a técnica adesiva resultaram nove grupos (n = 12). Inicialmente, com os compósitos foram realizados testes de ME e RF. Sequencialmente, cada fragmento foi reparado com os diferentes sistemas adesivos. Todas as amostras foram submetidas ao teste de RU por microtração em uma máquina de ensaio universal. Os dados foram submetidos ao teste de normalidade e ao teste paramétrico ANOVA. A resina Charisma apresentou os maiores valores no ME e RF em relação às demais resinas compostas (p <0,05). O maior valor de RU foi para a resina Charisma reparada com silano + adesivo. Os menores valores de RU foram na resina Bulk Fill, independentemente do sistema adesivo. Os resultados no ME e RF mostraram que as resinas Filtek Z350 obtiveram os melhores resultados, enquanto as resinas bulk fill obtiveram resultados inferiores. Conclui-se que as resinas Charisma e Filtek Z350 apresentaram melhores resultados. Entretanto, no grupo de bulk fill obteve-se as menores médias de RU, RF e ME, bem como o menor valor no ME. (AU)

5.
Rev. bras. med. esporte ; 27(7): 686-688, July 2021. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1351822

ABSTRACT

ABSTRACT Introduction: Centrifugal strength is an important element for strength quality. Developing muscle centrifugal strength can effectively increase the stability of lower limbs and reduce the risk of injury. Objective: To explore the characteristics of contractile force of flexor ahods in strength training and rehabilitation training, and the extensor muscles of the knee joint in athletes with different speeds of centripetal force. Methods: The knee joint muscle group of 8 first-level male high jumpers and 8 second-level male high jumpers were tested by isokinetic centrifugal contraction; the angular test velocity was 60 °/s, 120 °/s, 240 °/s, and the indexes included peak torque, relative peak torque (peak torque/body weight), and the peak torque flexural extension ratio. Results: With the centrifugal contraction of the knee joint muscle group (P < 0.05), the second-level high jumpers should increase the ability of the knee flexor muscle group of the take-off leg. In the case of constant velocity centrifugal contraction (P < 0.01), taking off time must be reduced, that is, taking off speed must be accelerated. Conclusions: The difference in the knee joint muscle isokinetic test results is one of the reasons for the difference in knee joint flexor and extensor muscle contractility under the different speed forces of high jumpers. Level of evidence II; Therapeutic studies - investigation of treatment results.


RESUMO Introdução: A força centrífuga é um elemento importante na qualidade de força. O desenvolvimento da força centrífuga muscular pode, efetivamente, aumentar a estabilidade dos membros inferiores e reduzir o risco de lesões. Objetivo: Explorar as características da força contrátil do músculo flexor no treinamento de força e de reabilitação, e os músculos extensores da junta do joelho em atletas com diferentes velocidades de força centrípeta. Métodos: O grupo muscular da articulação do joelho de oito saltadores de primeiro escalão do sexo masculino, e oito saltadores de segundo escalão do sexo masculino foi testado por contração centrífuga isocinética. A velocidade de teste angular foi de 60 °/s, 120 °/s, 240 °/s, e os índices incluíram torque de pico, torque de pico relativo (torque de pico/peso corporal) e a razão extensão-flexão de torque de pico. Resultados: Na contração centrífuga do grupo muscular da articulação do joelho (P < 0,05), os saltadores de segundo escalão devem aumentar a habilidade do grupo muscular flexor do joelho da perna de arranque. No caso da contração centrífuga de velocidade constante (P < 0,01), o tempo de arranque deve ser reduzido, ou seja, a velocidade de arranque deve ser acelerada. Conclusões: A diferença nos resultados dos testes isocinéticos do músculo da junta do joelho é uma das razões para a diferença na contratilidade muscular flexor e extensor da junta do joelho sob forças de velocidade diferentes em saltadores. Nível de evidência II; Estudos terapêuticos - investigação de resultados de tratamento.


Resumen Introducción: La fuerza centrífuga es un elemento importante en la calidad de fuerza. El desarrollo de la fuerza centrífuga muscular puede efectivamente aumentar la estabilidad de los miembros inferiores y reducir el riesgo de lesiones. Objetivo: Explorar las características de la fuerza contráctil del músculo flexor en el entrenamiento de fuerza y de rehabilitación, y los músculos extensores de la articulación de la rodilla en atletas con diferentes velocidades de fuerza centrípeta. Métodos: Se testó el grupo muscular de la articulación de la rodilla de 8 saltadores de primer escalafón del sexo masculino, y 8 saltadores de segundo escalafón del sexo masculino por contracción centrífuga isocinética. La velocidad de prueba angular fue de 60 °/s, 120 °/s, 240 °/s, y los índices incluyeron torque de pico, torque de pico relativo (torque de pico/peso corporal) y la razón extensión-flexión de torque de pico. Resultados: En la contracción centrífuga del grupo muscular de la articulación de la rodilla (P<0,05), los saltadores de segundo escalafón deben aumentar la habilidad del grupo muscular flexor de la rodilla de la pierna de arrancada. En el caso de la contracción centrífuga de velocidad constante (P<0,01), el tiempo de arrancada debe reducirse, o sea, la velocidad de arrancada debe acelerar. Conclusiones: La diferencia en los resultados de las pruebas isocinéticas del músculo de la articulación de la rodilla es una de las razones para la diferencia en la contractilidad muscular flexor y extensor de la articulación de la rodilla bajo fuerzas de velocidad diferentes en saltadores. Nivel de evidencia II; Estudios terapéuticos - investigación de resultados de tratamiento.

6.
J. bras. econ. saúde (Impr.) ; 13(1): 55-65, Abril/2021.
Article in Portuguese | ECOS, LILACS | ID: biblio-1252727

ABSTRACT

Objetivo: Analisar o custo-efetividade da utilização de ureteroscópios flexíveis descartáveis em comparação com o uso de ureteroscópios flexíveis reprocessáveis. Métodos: Revisão integrativa de literatura realizada nos bancos de dados SciELO, LILACS e MEDLINE, utilizando os descritores "ureteroscopia", "resistência à flexão", "marketing", "análise de custo-benefício" e "esterilização", cujo objeto trata das vantagens custo-efetivas da utilização do ureteroscópio flexível descartável. Resultados: Trinta e cinco artigos foram encontrados, sendo quatro utilizados no estudo. Além disso, características de sete modelos de ureteroscópios flexíveis comercializados no Brasil mais conhecidos atualmente foram apresentadas. Os resultados foram baseados na análise conjunta dos artigos selecionados e características dos modelos de flexíveis apresentados e discutidos em duas categorias: a evolução dos ureteroscópios flexíveis e marketing mix ­ ureteroscópios flexíveis de uso único. Conclusão: Apesar da escassez de pesquisas que se aprofundem em custos de utilização de um ureteroscópio flexível de uso único, comparado a um reprocessável, são notórios os benefícios advindos das inovações agregadas a esses dispositivos, dando retorno positivo tanto para o profissional que faz seu uso deles quanto para o paciente, fazendo-se necessário analisar mais profundamente a possibilidade de migração da "cultura" de uso de ureteroscópios flexíveis reprocessáveis para os descartáveis


Objective: To analyze the cost-effectiveness of using disposable flexible ureteroscopes versus using reprocessable flexible ureteroscopes. Methods: Integrative literature review conducted in the SciELO, LILACS and MEDLINE databases, using the descriptors ureteroscopy, flexion resistance, marketing, cost-benefit analysis, and sterilization, whose object deals with the cost-effective advantages of using the flexible ureteroscope disposable. Results: Thirty-five articles were found and four were used in the study. In addition, characteristics of seven models of flexible ureteroscopes commercialized in Brazil, that are currently better known, were presented. The results were based on a joint analysis of the selected articles and characteristics of the flexible models presented, and discussed in two categories: the evolution of flexible ureteroscopes; and marketing mix - flexible single-use ureteroscopes. Conclusion: Despite the scarcity of research that deepens the costs of using a flexible single-use ureteroscope when compared to a reprocessable one, the benefits arising from the innovations added to these devices are notorious, giving a positive return both to the professional who uses it and to the patient, making it necessary to further analyze the possibility of migration from the "culture" of using flexible reprocessable ureteroscopes to disposable ones


Subject(s)
Sterilization , Cost-Benefit Analysis , Ureteroscopy , Flexural Strength
7.
Araçatuba; s.n; 2021. 58 p. tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1435804

ABSTRACT

A aplicação de selantes de superfície poderá ajudar na diminuição da degradação superficial dos blocos de PMMA para CAD/CAM frente aos desafios de absorção de água, variação de temperatura e desafio erosivo causada pelo suco gástrico (frequente em pacientes com refluxo gastroesofágico (DRGE) ou bulimia. Contudo, poucos estudos na área odontológica foram realizados com essas variáveis, sendo necessário o aprofundamento sobre o assunto. Diante disso, o objetivo deste estudo foi avaliar o impacto de diferentes selantes de superfície (Biscovel LV e Palaseal) na preservação das propriedades mecânicas de polímero de PMMA para CAD/CAM, submetidos a termociclagem (T1 - 5.000 ciclos, de 5 e 55oC ; T2 ­ 10.000 ciclos, de 5 e 55oC) e desafio erosivo (DE1 - imersão em HCl 5% (pH=2,0) durante 45 horas e DE2- 91 horas), por meio da rugosidade de superfície (Ra), microdureza Knoop (MK), resistência flexural (RF) e módulo de elasticidade (ME). Foram confeccionados 90 espécimes quadrados (10x10x3 mm) para as análises de Ra e MK e 180 espécimes retangulares (25x2x2mm) para as análises de RF e ME. Os espécimes foram divididos em grupos (n=10) de acordo com o tratamento de superfície e envelhecimento. Os polimentos realizados foram: PA - pontas de borracha Astropol; PA+SB - polimento com PA + aplicação de selante de superfície Biscover LV e PA+SP - polimento com PA + aplicação de selante de superfície Palaseal. As análises foram realizadas após os tratamentos de superfície e após os períodos dos envelhecimentos. Os dados obtidos foram submetidos ao ANOVA (2 fatores), teste Bonferroni (α=0,05) e a análise de regressão linear simples. Na análise de Ra, em todos os períodos de termociclagem o grupo PA obteve os maiores valores de Ra e PA+SP os menores, com diferença significativa entre eles (p< 0.05). De acordo com a análise de regressão linear, todos os grupos apresentaram tendência linear crescente. Já após DE1 e DE2 os três grupos diferiram estatisticamente entre si (p< 0.05), sendo classificados em ordem crescente de rugosidade em PA+SP < PA+SB< PA. O grupo PA+SP manteve os valores de Ra no decorrer dos períodos de análises. Para RF, ocorreu diminuição significativa dos valores de RF do grupo PA após T1 e T2, diferindo estatisticamente dos demais grupos (p< 0.05). O desafio erosivo diminuiu de forma significante (p< 0.05) os valores de RF dos grupos PA e PA+SP após DE1 e, do grupo PA+SB após DE2. Não houve diferenças significativas nas análises de MK e ME, independente dos tratamentos de superfície e envelhecimentos. Conclui-se que os selantes de superfície foram capazes de preservar a rugosidade de superfície e resistência flexural de polímero de PMMA para CAD/CAM submetidos a termociclagem ou desafio erosivo(AU)


The application of surface sealants can help to reduce the surface degradation of PMMA blocks for CAD/CAM in the face of water absorption challenges, temperature variation and erosive challenge caused by gastric juice (common in patients with gastroesophageal reflux (DRGE) or bulimia. However, few studies in the field of dentistry have been conducted with these variables, requiring a more in-depth look at the subject. Therefore, the aim of this study was to evaluate the impact of different surface sealants (Biscovel LV and Palaseal) on the preservation of mechanical properties of PMMA polymer for CAD/CAM, subjected to thermocycling (T1 - 5,000 cycles, from 5 and 55oC; T2 - 10,000 cycles, from 5 to 55oC) and erosive challenge (DE1 - immersion in 5% HCl (pH=2.0) for 45 hours and DE2-91 hours), through surface roughness (Ra), Knoop microhardness (MK), flexural strength (RF) and modulus of elasticity (ME). The Ra and MK analyzes and 180 rectangular specimens (25x2x2mm) for the RF and ME analyses. Specimens were divided into groups (n=10) according to surface treatment and aging. The polishes performed were: PA - Astropol rubber tips; PA+SB - PA polish + application of Biscover LV surface sealant and PA+SP - polish with PA + application of Palaseal surface sealant. Analyzes were performed after surface treatments and after aging periods. The data obtained were submitted to ANOVA (2 factors), Bonferroni test (α=0.05) and simple linear regression analysis. In the analysis of Ra, in all thermocycling periods, the PA group had the highest values of Ra and PA+SP the lowest, with a significant difference between them (p< 0.05). According to the linear regression analysis, all groups showed an increasing linear trend. After DE1 and DE2, the three groups differed statistically from each other (p< 0.05), being classified in ascending order of roughness in PA+SP < PA+SB < PA. The PA+SP group maintained the Ra values throughout the analysis periods. For RF, there was a significant decrease in the RF values of the PA group after T1 and T2, differing statistically from the others groups (p< 0.05). The erosive challenge significantly decreased (p< 0.05) the RF values of the PA and PA+SP groups after DE1 and of the PA+SB group after DE2. There were no significant differences in the MK and ME analyses, regardless of surface treatments and aging. It was concluded that the surface sealants were able to preserve the surface roughness and flexural strength of PMMA polymer for CAD/CAM submitted to thermocycling or erosive challenge(AU)


Subject(s)
Polymers , Dental Prosthesis , Polymethyl Methacrylate , Computer-Aided Design , Dental Materials , Denture, Partial, Temporary , Flexural Strength
8.
Braz. dent. sci ; 24(4): 1-10, 2021. tab, ilus, graf
Article in English | LILACS, BBO | ID: biblio-1293129

ABSTRACT

Objective: The purpose of this in vitro study is to evaluate the effect of four finish line configurations and two cement types on the fracture resistance of zirconia copings. Material and Methods: Forty yttrium tetragonal zirconia polycrystals copings were manufactured on epoxy resin dies with four preparation designs: knife edge, chamfer, deep chamfer 0.5, 1 mm and shoulder 1 mm. The copings were cemented with two cement types (glass ionomer and resin cement); (n = 5). Two strain gauges were attached on each coping before they were vertically loaded till fracture with a universal testing machine. Data were analyzed by 2-way analysis of variance ANOVA (p < .05). Fractured specimens were examined for mode of failure with digital microscope. Results: Knife edge showed the highest mean fracture resistance (987.04 ± 94.18) followed by Chamfer (883.28 ± 205.42) followed by Shoulder (828.64 ± 227.79) and finally Deep chamfer finish line (767.66 ± 207.09) with no statistically significant difference. Resin cemented copings had higher mean Fracture resistance (911.76 ± 167.95) than glass ionomer cemented copings (821.55 ± 224.24) with no statistically significant difference. Knife edge had the highest strain mean values on the buccal (374.04 ± 195.43) and lingual (235.80 ± 103.46) surface. Shoulder finish line showed the lowest mean strain values on the buccal (127.47 ± 40.32) and lingual (68.35 ± 80.68) with no statistically significant difference. Resin cemented copings had higher buccal (295.05 ± 167.92) and lingual (197.38 ± 99.85) mean strain values than glass ionomer copings (149.14 ± 60.94) and (90.27 ± 55.62) with no statistically significant difference. Conclusion: Vertical knife edge finish line is a promising alternative and either adhesive or conventional cementation can be used with zirconia copings (AU)


Objetivo: O objetivo deste estudo in vitro é avaliar o efeito de quatro configurações de términos cervicais e dois tipos de cimentos na resistência à fratura de copings de zircônia. Material e Métodos: Quarenta copings de zircônia tetragonal policristalina estabilizada por ítrio foram confeccionados em matrizes de resina epóxi com quatro tipos de términos cervicais: lâmina de faca, chanfro, chanfro largo 0,5, 1 mm e ombro 1 mm. Os copings foram cimentados com dois tipos de cimento (ionômero de vidro e cimento resinoso); (n = 5). Dois extensômetros foram fixados em cada coping antes de serem carregados verticalmente até a fratura com uma máquina de teste universal. Os dados foram analisados por análise de variância ANOVA 2 fatores (p < 0,05). Os espécimes fraturados foram examinados quanto ao modo de falha com microscópio digital. Resultados: A Lâmina de faca apresentou a maior média de resistência à fratura (987,04 ± 94,18) seguida pelo Chanfro (883,28 ± 205,42), pelo Ombro (828,64 ± 227,79) e finalmente o Chanfro largo (767,66 ± 207,09), sem diferença estatisticamente significativa. Os copings cimentados com cimento resinoso apresentaram maior média de resistência à fratura (911,76 ± 167,95) em relação aos copings cimentados com ionômero de vidro (821,55 ± 224,24), sem diferença estatisticamente significativa. A lâmina de faca apresentou os maiores valores médios de deformação na superfície vestibular (374,04 ± 195,43) e lingual (235,80 ± 103,46). O término em ombro apresentou os menores valores médios de deformação na superfície vestibular (127,47 ± 40,32) e lingual (68,35 ± 80,68), sem diferença estatisticamente significativa. Os copings cimentados com resina apresentaram maiores valores médios de deformação na superfície vestibular (295,05 ± 167,92) e lingual (197,38 ± 99,85) do que os copings cimentados com ionômero de vidro (149,14 ± 60,94) e (90,27 ± 55,62), sem diferença estatisticamente significativa. Conclusão: O término cervical em lâmina de faca é uma alternativa promissora e a cimentação adesiva ou convencional pode ser usada na cimentação de copings de zircônia. (AU)


Subject(s)
Prosthodontics , Zirconium , Cementation , Tooth Preparation , Flexural Strength
9.
Dental press j. orthod. (Impr.) ; 25(6): 43-48, Nov.-Dec. 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1154053

ABSTRACT

ABSTRACT Objective: To evaluate different concentrations of Galla chinensis extract (GCE) added to poly(methyl methacrylate) (PMMA), which is widely used for fabrication of removable orthodontic appliances, regarding the effectiveness of this herbal extract on antimicrobial effect and flexural strength of PMMA. Methods: Acrylic resin samples containing 0.4%, 0.8% and 1.6% GCE were prepared. Flexural strength was investigated via three-point flexural strength test for the 15 acrylic resin blocks of each concentration. Disk diffusion test was used to evaluate antibacterial effects of incorporating the same concentrations of GCE into acrylic resin. All these three groups were compared with the control group, with no added GCE, regarding flexural strength and antibacterial properties. Results: Comparison of flexural strength between the three study groups and the control group showed significant differences between the groups (P=0.018). However, there was no significant difference between the groups containing GCE. There were significant differences in antimicrobial activity between the four groups (P=0.026). Conclusion: Within the limitations of this study, it is suggested that incorporation of GCE into PMMA would be beneficial for antimicrobial activity and flexural strength of PMMA, but further studies on other physical properties and antimicrobial effects on other bacterial strain would be beneficial prior to clinical investigations.


RESUMO Objetivo: Avaliar se diferentes concentrações de extrato de Galla chinensis (EGC) adicionado ao polimetilmetacrilato (PMMA), que é amplamente utilizado para a fabricação de aparelhos ortodônticos removíveis, interferem no efeito antimicrobiano desse extrato e na resistência à flexão do PMMA. Métodos: Foram preparadas amostras de resina acrílica com concentrações de 0,4%, 0,8% e 1,6% de EGC. Para a avaliação da resistência à flexão, utilizou-se o teste de flexão em três pontos para as 15 amostras de resina em cada concentração. O teste de disco-difusão foi utilizado para avaliar os efeitos antibacterianos da incorporação das mesmas concentrações de EGC na resina acrílica. Esses três grupos foram comparados ao grupo controle, sem adição do EGC, em relação à resistência à flexão e quanto às propriedades antimicrobianas. Resultados: As comparações dos três grupos com o grupo controle mostraram diferenças significativas (p=0,018) para a resistência à flexão. Entretanto, não houve diferença significativa entre os grupos contendo EGC. Foram encontradas diferenças significativas na atividade antimicrobiana entre os quatro grupos (p=0,026). Conclusão: Dentro das limitações desse estudo, parece que a incorporação de EGC no PMMA seria benéfica para a atividade antimicrobiana e a resistência à flexão do PMMA. Porém, estudos adicionais sobre outras propriedades físicas e sobre os efeitos antimicrobianos contra diferentes cepas de bactérias seriam interessantes antes de se fazer pesquisas clínicas.


Subject(s)
Acrylic Resins , Denture Bases , Flexural Strength , Anti-Infective Agents , Anti-Bacterial Agents/pharmacology , Materials Testing , Plant Extracts/pharmacology
10.
Acta odontol. latinoam ; 33(2): 135-142, Sept. 2020. graf
Article in English | LILACS | ID: biblio-1130744

ABSTRACT

ABSTRACT This study evaluated the influence of the mode and time of solvent evaporation on the tensile strength (TS), flexural strength (FS) and elastic modulus (EM) of two adhesive systems: Scotchbond Multipurpose (SBMP) and Clearfil SE (CSEB). For this purpose, rectangular samples (2x1x7 mm) were prepared with 10 μL of primer and the solvents were evaporated with air spray at (23±1) ºC, (40±1) ºC and negative control (without spray). For each temperature, the times of 5, 20, 30, and 60 seconds were investigated. The statistical results showed that evaporation at 40±1ºC resulted in better EM for the two adhesives tested and all the evaporation times evaluated. However, there were no significant differences between the times and modes of evaporation for TS. The results of this study indicate that evaporation at a temperature of (40±1) °C could improve the elastic modulus of both adhesives tested, regardless of the evaporating time.


RESUMO Este estudo avaliou a influência do modo e do tempo de evaporação do solvente na resistência à tração (RT), resistência à flexão (RF) e módulo de elasticidade (MR) de dois sistemas adesivos: Scotchbond Multipurpose (SBMP) e Clearfil SE (CSEB). Para isso, amostras retangulares (2x1x7 mm) foram preparadas com 10 μL de primer e os solventes foram evaporados com aerossol a (23±1) ºC, (40±1) ºC e controle negativo (sem aerossol). Para cada temperatura, foram avaliados os tempos de 5, 20, 30 e 60 segundos. Os resultados estatísticos mostraram que a evaporação a (40±1) ºC resultou em melhor MR para os dois adesivos testados e todos os tempos de evaporação avaliados. No entanto, não houve diferenças significativas entre os tempos e modos de evaporação na RT. Os resultados deste estudo indicam que a evaporação a uma temperatura de (40±1) °C poderia melhorar o módulo de elasticidade de ambos os adesivos testados, independentemente do tempo de evaporação.


Subject(s)
Humans , Solvents/pharmacology , Tensile Strength , Adhesives/chemistry , Dentin-Bonding Agents/chemistry , Dental Cements/chemistry , Volatilization , Materials Testing , Desiccation
11.
Odontología (Ecuad.) ; 22(2): 45-59, 2020.
Article in Spanish | LILACS | ID: biblio-1103546

ABSTRACT

En conductos radiculares curvos, la utilización de limas que eviten desvíos y fracturas del instrumento por fatiga y que mantengan curvaturas originales son aspectos importantes en el tratamiento endodóntico. Ob-jetivo: Se evaluó la resistencia a la fatiga cíclica de cuatro sistemas reciprocantes en una canaleta dinámica que simuló tres curvaturas diferentes. Materiales y Método: Estudio in vitro; la muestra con 48 limas se dividió en cuatro grupos (n= 12/grupo): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) y Reciproc® Blue (RB), cuatro limas de cada sistema se usaron en una canaleta que simuló tres angulaciones 45°, 60° y 90°; montadas en un motor X-Smart Plus®, las limas se introdujeron 23 mm en los conductos para ser activadas continuamente a 300/500 oscilaciones/minuto hasta que se produjo la fractura. Se registró tiempo y zona de fractura. Se realizó el test Kruskal Wallis con un nivel de confianza del 95% para las comparaciones. Resul-tados: RB presentó mayor resistencia a la fatiga cíclica que WO y WOG en todas las angulaciones y que R a 90° (p= <0,05). R presentó mayor resistencia que WOG a 45° y 60°, sin embargo, a 90° WOG fue superior que R y WO (p<0,05). No hubo diferencias en cuanto a la zona de fractura que aconteció en la porción apical. Conclusiones: La resistencia se reduce cuando aumenta el grado de curvatura. RB fue significativamente más resistente a la fatiga cíclica que WO y WOG en todas las angulaciones y que R a 90°. La zona de fractura se produjo en la porción apical de las limas.


In the curved canals, the use of files that avoid deviations and fractures of the instrument due to fatigue and that maintain original curvatures are important aspects in endodontic treatment. Objective: The resistance to cyclic fatigue of four reciprocating systems was evaluated in a dynamic gutter that stimulated three different curvatures. Materials and Method: In vitro study, the sample with 48 files was divided into four groups (n = 12 /group): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) and Reciproc® Blue (RB), four files from each system were used in a gutter that simulated three angulations 45o , 60 o and 90 o . The files which were mounted on an X-smart Plus® were inserted 23 mm into the conduits to be continuously activated at 300/500 oscillations per minute until the fracture occurred. Time and fracture zone were recorded. The Krustal Wallis test was performed with a 95% confidence level for the comparisons. Results: RB presented greater resis-tance to cyclic fatigue than WO and WOG at 45o and 60o, however, at 90o WOG was higher than R and WO (p<0.05). There were no differences regarding the fracture zone occurred in the apical portion. Conclusions: The resistance decreases when the degree of curvature increases. RB was significantly more resistance to cyclic fatigue than WO and WOG at all angulations and R at 90o. The fracture zone occurred in the apical portion of the files.


Em canais radiculares curvos, o uso de limas que evitem desvios e fraturas do instrumento devido à fadiga e que mantêm as curvaturas originais são aspectos importantes no tratamento endodôntico. Objetivo: avaliar a resistência à fadiga cíclica de quatro sistemas reciprocantes em uma canaleta artificial que simula três curva-turas diferentes. Materiais e Método: estudo in vitro; a amostra com 48 limas foi dividida em quatro grupos (n = 12 / grupo): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) e Reciproc® Blue (RB), quatro limas de cada sistema foram usadas em uma canaleta que simulo três angulações 45 °, 60 ° e 90 °; se montaram em um motor X Smart Plus®, as limas foram inseridas 23 mm nos condutos para serem ativadas continuamente a 300/350 oscilações / minuto até ocorrer uma fratura. O tempo e a zona de fratura foram registrados. O teste de Kruskal Wallis foi realizado com um nível de confiança de 95% para as comparações. Resultados: O RB apresenta maior resistência à fadiga cíclica que o WO e o WOG em todas as angulações e que R a 90 ° (p = <0,05). R apresentou maior resistência que WOG a 45 ° e 60 °, no entanto, a 90 ° WOG foi maior que R e WO (p <0,05). No existiu diferença na zona de fratura que ocorreu na porção apical. Conclusões: a resistência diminui quando o grau de curvatura aumenta. RB foi significativamente mais resistente à fadiga cíclica do que WO e WOG em todos os ângulos e R a 90 °. A zona de fratura ocorre na parte apical das limas.


Subject(s)
Dental Pulp Cavity , Endodontics , Flexural Strength , Stress, Mechanical , In Vitro Techniques
12.
RFO UPF ; 24(2): 256-262, maio/ago. 2 2019. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1049445

ABSTRACT

Objetivo: avaliar a influência de diferentes modos de polimerização sobre a resistência à flexão de três pontos de duas resinas compostas. Métodos: foram confeccionadas 88 amostras, sendo divididas em dois grupos, conforme a resina composta utilizada: Filtek Z350 XT e Forma. Os grupos foram subdivididos, de acordo com diferentes modos de polimerização, em: G1- Z350 por 20s a 1.000 mw/cm²; G2- Forma por 20s a 1.000 mw/cm²; G3- Z350 por 20s a 1.000 mw/cm² e micro-ondas por 3 minutos em 450w; G4- Forma por 20s a 1.000 mw/cm² e micro-ondas por 3 minutos em 450w; G5- Z350 por 2 vezes de 3s a 3.200 mw/cm²; G6- Forma por 2 vezes de 3s a 3.200 mw/cm²; G7- Z350 por 2 vezes de 3s a 3.200 mw/cm² e micro-ondas por 3 minutos em 450w; G8- Forma por 2 vezes de 3s a 3.200 mw/cm² e micro-ondas por 3 minutos em 450w. As amostras foram submetidas ao teste de resistência à flexão de 3 pontos, sob taxa de carregamento de 50 N/min, até a falha completa. Os dados foram analisados estatisticamente por análise de variância com dois fatores (two-way ANOVA) e teste de Tukey. Resultados: não houve diferenças estatísticas entre as resinas compostas e os modos de polimerização utilizados. Conclusão: de acordo com os resultados do estudo, e dentre suas limitações, os modos de polimerização não influenciaram a resistência à flexão, independentemente da resina composta testada. (AU)


Objective: to evaluate the influence of different polymerization modes on the three-point flexural strength of two composite resins. Methods: 88 samples were produced and divided into two groups according to the composite resin used: Filtek Z350 XT and Forma. The groups were subdivided according to different polymerization modes into: G1- Z350 for 20 s at 1000 mw/cm²; G2- Forma for 20 s at 1000 mw/cm²; G3- Z350 for 20 s at 1000 mw/cm² and microwave for 3 min at 450w; G4- Forma for 20 s at 1000 mw/cm² and microwave for 3 min at 450w; G5- Z350 2x for 3 s at 3200 mw/cm²; G6- Forma 2x for 3 s at 3200 mw/cm²; G7- Z350 2x for 3 s at 3200 mw/cm² and microwave for 3 min at 450w; and G8- Forma 2x for 3 s at 3200 mw/cm² and microwave for 3 min at 450w. The samples were subjected to the three-point flexural strength test under a 50 N/min loading rate until complete failure. The data were statistically analyzed using two-way analysis of variance (two-way ANOVA) and Tukey's test. Results: there were no statistical differences between the composite resins and the polymerization modes used. Conclusion: according to the study results and within its limitations, the polymerization modes did not affect flexural strength, regardless of the composite resin tested. (AU)


Subject(s)
Composite Resins/chemistry , Polymerization , Flexural Strength , Reference Values , Materials Testing , Analysis of Variance , Nanoparticles/chemistry , Light-Curing of Dental Adhesives/methods , Microwaves
13.
Rev. bras. anestesiol ; 69(1): 104-108, Jan.-Feb. 2019. tab, graf
Article in English | LILACS | ID: biblio-977429

ABSTRACT

Abstract Background: A patient's ability to move his/her fingers during hand surgery may be helpful to surgeons because it allows the effectiveness of the intervention evaluation and prediction of hand function in the postoperative period. The purpose of this case series is to demonstrate the efficacy of an ultrasound-guided peripheral nerve block technique to maintain the hand flexor and extensor muscles motor function and discuss the benefits of the technique for trigger finger surgery. Case report: Ten patients scheduled to undergo trigger finger surgery were selected. The goal was to maintain flexion and extension of the fingers during the procedure. Thus, ultrasound-guided ulnar, radial, and medial nerve block was performed in the distal third of the forearm, at 5-7 cm proximal to the wrist. The block was performed with 5 mL of 0.375% bupivacaine on each nerve. All procedures were uneventfully performed maintaining the flexion and extension of the fingers. In two cases, it was observed that the motricity maintenance and the patients' ability to move their fingers when requested allowed the success of the surgical procedure after the third intraoperative evaluation. Conclusion: This case series shows that it is possible to maintain the motor function of the hand flexor and extensor muscles to perform finger trigger surgeries using specific ultrasound-guided distal blocks.


Resumo Justificativa: A capacidade de um paciente mover os dedos durante a cirurgia da mão pode ser útil para o cirurgião porque permite a avaliação da eficácia da intervenção e a predição da função da mão no pós-operatório. O objetivo desta série de casos é demonstrar a eficácia de uma técnica de bloqueio de nervo periférico guiado por ultrassom na manutenção da função motora dos músculos flexores e extensores da mão e discutir os benefícios da técnica para cirurgias de liberação de dedo em gatilho. Relato de caso: Foram selecionados 10 pacientes em programação para cirurgia de liberação de dedo em gatilho. O objetivo era manter a flexão e a extensão dos dedos durante o procedimento. Dessa forma, o bloqueio dos nervos ulnar, radial e mediano, guiados por ultrassom, foi feito no terço distal do antebraço, 5 a 7 cm proximais ao punho. O bloqueio foi feito com 5 mL de bupivacaína a 0,375% em cada nervo. Todos os procedimentos foram feitos sem complicações e com manutenção da flexão e extensão dos dedos. Em dois casos, observou-se que a manutenção da motricidade e a capacidade dos pacientes de mover os dedos quando solicitado permitiu o sucesso do procedimento cirúrgico após a terceira avaliação intraoperatória. Conclusão: Esta série de casos mostra que é possível manter a função motora dos músculos flexores e extensores da mão em cirurgias de liberação de dedo em gatilho por meio de bloqueios distais específicos guiados por ultrassom.


Subject(s)
Humans , Trigger Finger Disorder , Trigger Finger Disorder/physiopathology , Nerve Block/methods , Range of Motion, Articular , Ultrasonography , Intraoperative Period
14.
Braz. J. Vet. Res. Anim. Sci. (Online) ; 56(4): e157248, Dezembro 03, 2019. ilus, tab
Article in English | LILACS, VETINDEX | ID: biblio-1048074

ABSTRACT

The agreement between subjective and objective evaluation methods was studied to identify claudication in the pelvic limbs of horses before and after flexion tests were performed. Twenty-nine horses were equipped with a wireless system of inertial sensors and evaluated during seven times while trotting. Videos were recorded to be evaluated by three veterinarians, with different levels of experience, to evaluate the agreement between the two different methods and between the evaluators. The evaluators and the objective evaluation had a low rate of agreement, with the exception of moderate agreement between the objective evaluation and evaluator 1 to identify lameness after the left total flexion and moderate agreement in evaluating the response to the tests, between objective evaluation and evaluator 2, after right distal flexion. This shows that there was a low agreement among the evaluators and between them and the objective evaluation for identifying lameness, measuring the degree of lameness and the response to the flexion tests.(AU)


A concordância entre métodos de avaliação subjetiva e objetiva foi estudada para identificar claudicação nos membros pélvicos antes e após a realização dos testes de flexão. Vinte e nove cavalos foram equipados com um sistema de sensores inerciais sem fio e avaliados durante sete momentos enquanto troteavam. Vídeos foram gravados para serem avaliados por três veterinários com diferentes níveis de experiência, a fim de avaliar a concordância entre os dois métodos diferentes e entre os avaliadores. Os avaliadores e a avaliação objetiva tiveram uma baixa taxa de concordância, com exceção de uma moderada concordância entre avaliação objetiva e avaliador 1 para identificar claudicação após o teste de flexão total esquerdo e uma moderada concordância na avaliação da resposta aos testes, entre avaliação objetiva e avaliador 2, após o teste de flexão distal direito. Isso demonstra que houve uma baixa concordância entre os avaliadores e entre estes e a avaliação objetiva para identificação da claudicação, mensuração do grau de claudicação e resposta aos testes de flexão.(AU)


Subject(s)
Animals , Horses/anatomy & histology , Lameness, Animal/diagnosis
15.
Braz. dent. sci ; 22(2): 234-242, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-996919

ABSTRACT

Objective: The objective of this study was to evaluate the compressive strength, flexural strength and flexural modulus of high-viscosity, low-viscosity bulk-fill, and conventional nanohybrid resin composite materials alone and when covered with nano-hybrid resin composite at different incremental thicknesses on the bulk-fill composites. Material and Methods: Specimens (N=60) were fabricated from the following materials or their combinations (n=10 per group): a) conventional nano-hybrid composite Z550 (FK), b) high-viscosity bulk-fill composite (Tetric N Ceram-TBF), c) low-viscosity bulk-fill composite SDR (SDR), d) Sonicfill (SF), e) SDR (2 mm)+FK (2 mm), f) SDR (4 mm)+FK (4 mm). After 24 h water storage, compressive strength was measured in a universal testing machine (1 mm/min). Additional specimens (N=40) (25x2x2 mm3) were made from FK, TBF, SDR and SF in order to determine the flexural strength and the flexural modulus, (n=10) and subjected to three-point bending test (0.5 mm/min). Data were analyzed using one-way ANOVA and Tamhane's T2 post-hoc tests (p p<0.05). Results: The mean compressive strength (MPa) of the nano-hybrid composite (FK) was significantly higher (223.8±41.3) than those of the other groups (123±27 - 170±24) (p <0.001). SDR (4 mm)+FK (2 mm) showed significantly higher compressive strength than when covered with 4 mm (143±30) or when used alone (146±11) (p <0.05). The mean flexural strength (159±31) and the flexural modulus of FK (34±7) was significantly higher than that of the high- or low-viscosity bulk-fill composites (p<0.001). The mean flexural strength of SF (132±20) was significantly higher compared to TBF (95±25) (p <0.05). Conclusion: Bulk-fill resin composites demonstrated poorer mechanical properties compared to nano-hybrid composite but similar to that of SF. Increasing the thickness of low-viscosity bulk-fill composite (SDR) from 2 to 4 mm underneath the nano-hybrid composite (FK) can improve the mechanical properties of the bulk-fill composites.(AU)


Objetivo: O objetivo deste estudo foi avaliar a resistência à compressão, resistência à flexão e módulo de flexão de materiais compósitos de alta viscosidade, baixa viscosidade e compósitos nanohíbridos convencionais e quando cobertos com resina composta nano-híbrida em diferentes espessuras incrementais sobre os compósitos de resina tipo bulkfilll. Material e Métodos: Os espécimes (N = 60) foram fabricados a partir dos seguintes materiais ou suas combinações (n = 10 por grupo): a) compósito nano-híbrido convencional Z550 (FK), b) compósito de bulk-fill de alta viscosidade (Tetric N CeramTBF), c) compósito SDR (SDR) de bulk-fill de baixa viscosidade, d) Sonicfill (SF), e) SDR (2 mm) + FK (2 mm), f) SDR (4 mm) + FK (4 mm). Após 24 h de armazenamento em água, a resistência à compressão foi medida em uma máquina universal de ensaios (1 mm / min). Espécimes adicionais (N = 40) (25x2x2 mm3) foram confeccionados com FK, TBF, SDR e SF para determinação da resistência à flexão e do módulo de flexão, (n = 10) e submetidos ao teste de flexão de três pontos (0,5 mm / min). Os dados foram analisados utilizando one-way ANOVA e testes post-hoc T2 de Tamhane (p <0,05). Resultados: A resistência média à compressão (MPa) do compósito nano-híbrido (FK) foi significativamente maior (223,8 ± 41,3) que os demais grupos (123 ± 27 - 170 ± 24) (p <0,001). SDR (4 mm) + FK (2 mm) apresentou resistência à compressão significativamente maior do que quando coberta com 4 mm (143 ± 30) ou quando usada sozinha (146 ± 11) (p <0,05). A resistência à flexão média (159 ± 31) e o módulo de flexão de FK (34 ± 7) foram significativamente maiores do que os compósitos do tipo bulk-fill de alta ou baixa viscosidade (p <0,001). A resistência à flexão média do FS (132 ± 20) foi significativamente maior em comparação ao TBF (95 ± 25) (p <0,05). Conclusão: Os compósitos de resina do tipo bulk-fill demonstraram propriedades mecânicas mais insatisfatórias em comparação com o compósito nano-híbrido, mas semelhantes aos do SF. O aumento da espessura do composto de bulkfilll de baixa viscosidade (SDR) de 2 a 4 mm sob o compósito nano-híbrido (FK) pode melhorar as propriedades mecânicas dos compósitos de bulk-fill.(AU)


Subject(s)
Tensile Strength , Bite Force , Composite Resins
16.
São José dos Campos; s.n; 2019. 76 p. il., graf., tab..
Thesis in Portuguese | LILACS, BBO | ID: biblio-999012

ABSTRACT

O objetivo deste estudo foi avaliar se há alteração no comportamento mecânico e na aderência microbiológica da cerâmica à base de dissilicato de lítio com a técnica de pigmentação extrínseca aplicada, após ser submetida a diferentes condições experimentais. Foram confeccionadas 160 amostras, divididas em grupos com e sem pigmentação (n=80). Destes, cada grupo foi subdividido em Controle, Desgate, Biodegradação e Desgaste com Biodegradação (n=20).15 amostras de cada subgrupo foram submetidas ao teste de resistência à flexão e 5 para o teste de aderência microbiológica. As amostras passaram anteriormente por testes complementares para caracterização da superfície (rugosidade, perfilometria volumétrica e microscopia eletrônica de varredura (MEV)). Os resultados foram submetidos a análise estatística descritiva (média e desvio padrão) e inferencial, mediante o teste paramétrico de análise de variância (ANOVA) dois fatores e teste de Tukey ( = 0,05). O fator pigmentação extrínseca influenciou negativamente no comportamento mecânico da cerâmica, apresentando significância estatística (p = 0,000), assim como a interação entre o tipo de condição experimental e a pigmentação (p = 0,020). Entretanto, na aderência microbiológica, foi a condição experimental que influenciou negativamente no comportamento microbiológico (p = 0,000), assim como a interação entre a condição experimental e a pigmentação (p = 0,000). Nas análises complementares, observou-se que a interação entre os fatores aumentou a rugosidade superfial (p = 0,000) e aumentou o volume perdido pelo desgatse (p = 0,040). As microscopias da superficie mostram as características de cada grupo, mostrando as diferenças entre as condições experimentais com e sem pigmentação extrínseca. E as microscopias da aderência microbiológica ilustram e confirmam os resultados obtidos no teste estatístico. Concluiu-se que a pigmentação extrínseca altera as propriedades mecânicas da cerâmica de dissilicato de lítio, reduzindo a resistência à flexão e aumentando a rugosidade superficial e o desgaste. Porém, a aderência microbiológica foi aumentada pela condição experimental. Entretanto, a interação entre os fatores contribuiu para esse aumento e para agravar a alteração nas propriedades mecânicas(AU)


The objective of this study was to evaluate the mechanical and microbiological behavior of the ceramics based on lithium disilicate with extrinsic characterization. For this, 160 discs were made, divided into two large groups, with extrinsec characterization and without, after which each was divided into four groups (n = 20): Control, Wear, Biodegradation and Biodegradation with Wear. Fifteen samples from each group were submitted to the flexural strength test and 5 submitted to the microbiological adherence test. Prior to the destructive test of flexural strength, the representative samples of each group underwent complementary tests for surface characterization. The results were submitted to descriptive statistical analysis (mean and standard deviation) and inferential, using the parametric analysis of variance (ANOVA) two way and Tukey test ( = 0,05). The extrinsec characterization factor influenced the mechanical behavior of the ceramic, presenting statistical significance (p = 0.000), as well as the interaction between the type of experimental condition and the extrinsec characterization (p = 0.020). However, in the microbiological adherence, it was the experimental condition that influenced the microbiological behavior (p = 0.000), as well as the interaction between the experimental condition and the extrinsec characterization (p = 0.000). It was concluded that the makeup influenced the mechanical behavior of the ceramic, and the experimental condition influenced the microbiological adherence. The interaction between the factors influenced both the mechanical behavior and the microbiological adherence(AU)


Subject(s)
Humans , Organically Modified Ceramics/adverse effects , Bacterial Adhesion/immunology , Pigmentation/immunology
17.
Belo Horizonte; s.n; 2019. 138 p. ilus, tab, graf.
Thesis in English, Portuguese | BBO, LILACS | ID: biblio-1016420

ABSTRACT

Dentes bovinos têm sido utilizados como substitutos aos humanos em pesquisas odontológicas. Entretanto, faltam dados que suportem o uso da dentina radicular bovina, sobretudo, que analisem o efeito da idade nas propriedades do substrato. Assim, analisou-se o efeito da idade nos aspectos morfológicos, químicos e físicos das dentinas radiculares humana e bovina, em função dos terços da raiz. Trata-se de um estudo experimental, in vitro, aprovado pelo Comitê de Ética em Pesquisa (COEP-UFMG 1.803.933) e pela Comissão de Ética no Uso de Animais (CEUAUFMG 372/2016). A amostra foi composta por dentes unirradiculares, cujas dentinas radiculares foram categorizadas em: humana jovem (HJ, 20-30 anos); humana madura (HM, acima de 60 anos); bovina jovem (BJ, 24-36 meses); e bovina adulta (BA, acima de 48 meses). Os dentes foram seccionados abaixo da junção amelocementária e ao longo eixo da raiz, para a obtenção de hemisecções. Uma hemisecção foi escolhida e cortes foram feitos para a obtenção dos espécimes, conforme cada método de análise. Para as análises dos aspectos morfológicos ­ número, diâmetro e área dos túbulos dentinários ­ os espécimes foram analisados em Microscópio Eletrônico de Varredura. A composição química foi analisada por Espectroscopia de Raios X por Dispersão em Energia, Espectroscopia por Comprimento de Onda Dispersivo e Espectroscopia Raman por Transformada de Fourier. Na análise das propriedades mecânicas, os espécimes foram submetidos aos testes de nanoindentação, resistência à flexão em três pontos e compressão. Para a análise da resistência ao cisalhamento por extrusão, as raízes receberam tratamento endodôntico e foram fixados pinos de fibra de vidro com cimentos resinosos (dual convencional e autoadesivo). As raízes foram seccionadas nos terços radiculares e os espécimes testados em máquina universal de ensaios. Adicionalmente, avaliou-se o grau de conversão dos cimentos resinosos. Os dados foram analisados em software estatístico, nível de significância de 5%. A HM apresentou os menores valores para número, diâmetro e área de túbulos dentinários (p<0,05). A HM apresentou maiores valores de cálcio, razão Ca/P e concentração mineral relativa, com diminuição na organização e qualidade do colágeno (p<0,05). A HM apresentou os maiores valores de nanodureza, módulo de elasticidade e resistência à compressão, mas os menores valores de resistência à flexão e módulo de elasticidade à flexão (p<0,05). A HM apresentou os menores valores de resistência de união, com diferenças entre os terços radiculares (p<0,05). O grau de conversão dos cimentos apresentou uma diminuição ao longo dos terços radiculares (p<0,05). Concluiu-se que a idade possui um efeito nos aspectos morfológicos, químicos e físicos da dentina radicular humana, sem efeito na dentina bovina. Assim, quando da necessidade de substituição da dentina radicular humana pela bovina em pesquisas, é necessário considerar o efeito da idade nos desfechos analisados.


Bovine teeth have been used as a substitute for human teeth in dental research. However, there is a lack of data that support the use of bovine root dentin, mainly, that analyze the effect of age on the properties of the substrate. Thus, the effect of age on the morphological, chemical and physical aspects of human and bovine root dentin was analyzed, in function of the root thirds. This is an in vitro experimental study, approved by the Research Ethics Committee (protocol number: 1.803.933) and the Ethics Committee on the Use of Animals (protocol number: 372/2016). The sample was composed of single-rooted teeth and root dentin was categorized into: young human (YH, 20-30 years); old human (OH, above 60 years); young bovine (YB, 24-36 months); and adult bovine (AB, over 48 months). The roots were sectioned below the cement-enamel and longitudinally to produce two hemi-sections. One hemi-section was chosen and sections were made to obtain the specimens, according to each method of analysis. For the analyzes of the morphological aspects - number, diameter and area of the dentinal tubules - the specimens were analyzed in Scanning Electron Microscope. The chemical composition was analysed by Energy Dispersive Spectroscopy, Wavelength Dispersive Spectroscopy and Fourier Transformed Raman Spectroscopy. In the analysis of the mechanical properties, the specimens were submitted to nano-indentation, three-point flexural and compression tests. For the analysis of the push-out bond strength test, the roots received endodontic treatment and fiber post with resin cements (conventional and selfadhesive dual) were fixed. The roots were sectioned in the root thirds and the specimens tested in a universal testing machine. Additionally, the degree of conversion of the resin cements was evaluated. The data were analyzed in statistical software, level of significance of 5%. The OH presented the lowest values for number, diameter and area of dentinal tubules (p<0.05). OH showed higher values of calcium, Ca/P ratio and relative mineral concentration, with decrease in the organization and quality of the collagen (p<0.05). The OH showed the highest values of nano-hardness, elastic modulus and compressive strength, but the lowest values of flexural strength and flexural modulus (p<0.05). The OH presented the lowest values of bond strength, with differences among the root thirds (p<0.05). The degree of conversion of the cements showed a decrease along the root thirds (p<0.05). It was concluded that age has an effect on the morphological, chemical and physical aspects of human root dentin, with no effect on bovine dentin. Thus, when it is necessary to replace the human root dentin by the bovine in research, it is necessary to consider the effect of age on the analysed outcomes.


Subject(s)
Tooth Root , Resin Cements , Dental Pins , Dentin , Fractures, Compression , Elastic Modulus , Flexural Strength , Hardness Tests , Microscopy
18.
Belo Horizonte; s.n; 2019. 138 p. ilus, tab.
Thesis in English, Portuguese | LILACS, BBO | ID: biblio-1016737

ABSTRACT

Dentes bovinos têm sido utilizados como substitutos aos humanos em pesquisas odontológicas. Entretanto, faltam dados que suportem o uso da dentina radicular bovina, sobretudo, que analisem o efeito da idade nas propriedades do substrato. Assim, analisou-se o efeito da idade nos aspectos morfológicos, químicos e físicos das dentinas radiculares humana e bovina, em função dos terços da raiz. Trata-se de um estudo experimental, in vitro, aprovado pelo Comitê de Ética em Pesquisa (COEP-UFMG 1.803.933) e pela Comissão de Ética no Uso de Animais (CEUAUFMG 372/2016). A amostra foi composta por dentes unirradiculares, cujas dentinas radiculares foram categorizadas em: humana jovem (HJ, 20-30 anos); humana madura (HM, acima de 60 anos); bovina jovem (BJ, 24-36 meses); e bovina adulta (BA, acima de 48 meses). Os dentes foram seccionados abaixo da junção amelocementária e ao longo eixo da raiz, para a obtenção de hemisecções. Uma hemisecção foi escolhida e cortes foram feitos para a obtenção dos espécimes, conforme cada método de análise. Para as análises dos aspectos morfológicos ­ número, diâmetro e área dos túbulos dentinários ­ os espécimes foram analisados em Microscópio Eletrônico de Varredura. A composição química foi analisada por Espectroscopia de Raios X por Dispersão em Energia, Espectroscopia por Comprimento de Onda Dispersivo e Espectroscopia Raman por Transformada de Fourier. Na análise das propriedades mecânicas, os espécimes foram submetidos aos testes de nanoindentação, resistência à flexão em três pontos e compressão. Para a análise da resistência ao cisalhamento por extrusão, as raízes receberam tratamento endodôntico e foram fixados pinos de fibra de vidro com cimentos resinosos (dual convencional e autoadesivo). As raízes foram seccionadas nos terços radiculares e os espécimes testados em máquina universal de ensaios. Adicionalmente, avaliou-se o grau de conversão dos cimentos resinosos. Os dados foram analisados em software estatístico, nível de significância de 5%. A HM apresentou os menores valores para número, diâmetro e área de túbulos dentinários (p<0,05). A HM apresentou maiores valores de cálcio, razão Ca/P e concentração mineral relativa, com diminuição na organização e qualidade do colágeno (p<0,05). A HM apresentou os maiores valores de nanodureza, módulo de elasticidade e resistência à compressão, mas os menores valores de resistência à flexão e módulo de elasticidade à flexão (p<0,05). A HM apresentou os menores valores de resistência de união, com diferenças entre os terços radiculares (p<0,05). O grau de conversão dos cimentos apresentou uma diminuição ao longo dos terços radiculares (p<0,05). Concluiu-se que a idade possui um efeito nos aspectos morfológicos, químicos e físicos da dentina radicular humana, sem efeito na dentina bovina. Assim, quando da necessidade de substituição da dentina radicular humana pela bovina em pesquisas, é necessário considerar o efeito da idade nos desfechos analisados.


Bovine teeth have been used as a substitute for human teeth in dental research. However, there is a lack of data that support the use of bovine root dentin, mainly, that analyze the effect of age on the properties of the substrate. Thus, the effect of age on the morphological, chemical and physical aspects of human and bovine root dentin was analyzed, in function of the root thirds. This is an in vitro experimental study, approved by the Research Ethics Committee (protocol number: 1.803.933) and the Ethics Committee on the Use of Animals (protocol number: 372/2016). The sample was composed of single-rooted teeth and root dentin was categorized into: young human (YH, 20-30 years); old human (OH, above 60 years); young bovine (YB, 24-36 months); and adult bovine (AB, over 48 months). The roots were sectioned below the cement-enamel and longitudinally to produce two hemi-sections. One hemi-section was chosen and sections were made to obtain the specimens, according to each method of analysis. For the analyzes of the morphological aspects - number, diameter and area of the dentinal tubules - the specimens were analyzed in Scanning Electron Microscope. The chemical composition was analysed by Energy Dispersive Spectroscopy, Wavelength Dispersive Spectroscopy and Fourier Transformed Raman Spectroscopy. In the analysis of the mechanical properties, the specimens were submitted to nano-indentation, three-point flexural and compression tests. For the analysis of the push-out bond strength test, the roots received endodontic treatment and fiber post with resin cements (conventional and selfadhesive dual) were fixed. The roots were sectioned in the root thirds and the specimens tested in a universal testing machine. Additionally, the degree of conversion of the resin cements was evaluated. The data were analyzed in statistical software, level of significance of 5%. The OH presented the lowest values for number, diameter and area of dentinal tubules (p<0.05). OH showed higher values of calcium, Ca/P ratio and relative mineral concentration, with decrease in the organization and quality of the collagen (p<0.05). The OH showed the highest values of nano-hardness, elastic modulus and compressive strength, but the lowest values of flexural strength and flexural modulus (p<0.05). The OH presented the lowest values of bond strength, with differences among the root thirds (p<0.05). The degree of conversion of the cements showed a decrease along the root thirds (p<0.05). It was concluded that age has an effect on the morphological, chemical and physical aspects of human root dentin, with no effect on bovine dentin. Thus, when it is necessary to replace the human root dentin by the bovine in research, it is necessary to consider the effect of age on the analysed outcomes.


Subject(s)
Tooth Root , Resin Cements , Dental Pins , Dentin/anatomy & histology , Fractures, Compression , Flexural Strength , Hardness Tests , In Vitro Techniques , Microscopy, Electrochemical, Scanning , Microscopy
19.
São José dos Campos; s.n; 2019. 108 p. il., tab., graf..
Thesis in Portuguese | BBO, LILACS | ID: biblio-1017280

ABSTRACT

Neste estudo avaliou-se por caracterização mecânica e microestrutural, a degradação em meio bucal e in vitro da cerâmica Y-TZP sinterizada por energia de micro-ondas em comparação ao método convencional. Foram confeccionados noventa e seis discos por CAD-CAM (ISO 6872), sinterizados de modo convencional (C) 1530°C/120 minutos e por energia de micro-ondas (M) 1450°C/15 minutos. E submetidos à degradação hidrotérmica em reator pressurizado (E) (1,5h/150°C/3 bar) e à degradação in situ (B) (240 horas em meio bucal), formando-se 8 grupos (n = 12): M, C, ME, CE, MB, CB, MEB e CEB. Foram realizadas análises de contração volumétrica, difração de raios-X (DRX), rugosidade superficial (Ra e Rz), ângulo de contato, microscopia eletrônica de varredura (MEV), quantificação do biofilme por UFC/mL e análise de resistência mecânica por flexão biaxial. Os resultados obtidos foram analisados estatisticamente por t-Student, Anova dois e três fatores, e teste de Tukey (5%). Por DRX observou-se transformação de fase tetragonal para monoclínica (t-m) nos grupos envelhecidos, exceto para o grupo MB. Não foram observadas diferenças significantes na contração volumétrica (p=0,274), na rugosidade Ra (p=0,137) e Rz (p=0,187), assim como nos valores de ângulo de contato entre os métodos de sinterização (p=0,669). Por MEV observou-se a presença de formação de biofilme inicial e na contagem de Unidades Formadoras de Colônias (UFC/mL) foi maior quando os espécimes foram previamente envelhecidos in vitro (p=0,001). No ensaio de resistência à flexão biaxial foi observado o efeito interação (p=0,005) para as três variáveis, sinterização, envelhecimento in vitro e envelhecimento in situ, com aumento da resistência para os grupos sinterizados pelo método convencional após os envelhecimentos, devido ao aumento de tensão de transformação superficial. E houve equivalência estatística entre todos os grupos micro-ondas comparados aos grupos controle. Concluiu-se que o método de envelhecimento in situ por 240 horas foi capaz de transformar a fase t-m da superfície da cerâmica, sendo que a sinterização por energia de micro-ondas influenciou positivamente a resistência à degradação hidrotérmica à baixa temperatura (LTD), além da redução no tempo de sinterização em mais de 80%(AU)


In this study ir was evaluated the effect of in situ low temperature degradation of yttrium oxide stabilized tetragonal zirconia polycrystal (Y-TZP) ceramics sintered by microwave energy in comparison to the conventional method. Ninety-six discs milled by CAD/CAM (ISO 6872) were divided in: conventionally sintered (C) at 1530 ° C / 120 minutes and microwave energy (M) 1450°C / 15 minutes. Specimens were submitted to hydrothermal degradation in a pressurized reactor (E) (1.5h / 150°C / 3 bar) and in situ degradation (B) (240 hours in the buccal medium), forming eight groups (n=12): M, C, ME, CE, MB, CB, MEB and CEB. Specimens were evaluated through analysis of volumetric contraction, X-ray diffraction (XRD), surface roughness (Ra and Rz), contact angle, scanning electron microscopy (SEM), biofilm quantification by CFU / mL and biaxial flexural strength. Results were statistically analyzed through t-Student, two, three-way Anova and Tukey tests (5%). By XRD, tetragonal to monoclinic phase transformation (t-m) was observed in the aged groups, except for the MB group. No significant differences were observed in the volumetric contraction (p = 0.274), Ra roughness (p = 0.137) and Rz (p = 0.187), as well as contact angle values between sintering methods (p = 0.669). SEM images showed that the initial biofilm formation was observed after 8 hours in situ, an increase of CFU / mL occurred when the specimens were previously aged in vitro (p = 0.001). Regarding biaxial flexural strength, the interaction effect (p = 0.005) for the three variables, sintering method, hydrothermal aging and in situ aging was observed, with increased resistance for the sintered groups by the conventional method after aging, and statistical equivalence for the microwave groups, aged or not, compared to the control groups. The in situ aging method for 240 hours was induced the t-m phase transformation the surface of the ceramic, and sintering by microwave energy had a positive effect on the resistance to low temperature hydrothermal degradation (LTD), besides reduction in sintering time by more than 80%(AU)


Subject(s)
Humans , Dental Plaque/complications , Flexural Strength
20.
Arq. bras. med. vet. zootec. (Online) ; 70(3): 779-786, maio-jun. 2018. ilus, graf
Article in Portuguese | LILACS, VETINDEX | ID: biblio-911317

ABSTRACT

Fraturas ósseas podem ser corrigidas com a utilização de fixadores esqueléticos externos (FEE), método de estabilização bastante comum. Para tanto, têm-se utilizado barras conectoras de polimetilmetacrilato (PMMA) sem critério de diâmetro, as quais podem quebrar, se ficarem muito delgadas, ou ocasionar incômodo, quando muito pesadas e volumosas. O objetivo deste trabalho foi testar, por meio de ensaio biomecânico de compressão axial e flexão, qual é o diâmetro ideal da barra conectora de PMMA, correlacionado com o diâmetro ósseo para utilização em FEE tipo Ia. Utilizaram-se 24 úmeros para se realizarem medidas de comprimento, diâmetro, circunferência e ensaios biomecânicos. Após, foram confeccionadas barras de 1,5 vezes a média do diâmetro ósseo (grupo I), do mesmo diâmetro ósseo (grupo II) e de 0,5 vezes o diâmetro (grupo III). Com os resultados obtidos ao se compararem os valores dos ossos com os dos grupos II e III, verificou-se que as barras conectoras do grupo II mostraram-se mais resistentes do que o tecido ósseo no ensaio de compressão. No ensaio de flexão, os ossos resistiram mais quando comparados aos grupos II e III, sendo 4,3 vezes mais resistentes do que o grupo III nesse mesmo ensaio mecânico. Os resultados permitem um direcionamento para confecção de barras considerando-se o diâmetro ósseo como referência.(AU)


Bone fractures can be corrected from external skeletal fixators (ESF) in a fairly common internal stabilization method, in which connector bars polymethylmethacrylate (PMMA) is used. PMMA is used without criterion of diameter, and it can break if it is too thin or too heavy. It can be uncomfortable when bulky. The aim of this study was to test, through biomechanical axial compression and bending which is the ideal connector bar diameter PMMA, correlated to bone diameter for use in type Ia ESF. Twenty-four humerus were used to make measurements of length, diameter, circumference, and biomechanical testing. After the bars confected with 1.5 times the average diameter of the bone (group I), the same diameter (group II) and 0.5 times the diameter of the bone (group III). With the obtained results, using GII and GIII results, it was observed that the connector bars in group II were more resistant than the bones in the compression test. In the bending test, the bones resisted flexion strength when compared to group III and the group II was 4.3 times more resistant than group III in the same mechanical test. The results allow a direction for making bars considering bone diameter as a reference.(AU)


Subject(s)
Animals , Fracture Fixation/statistics & numerical data , Fractures, Compression/veterinary , Swine/injuries , Biomechanical Phenomena , Polymethyl Methacrylate
SELECTION OF CITATIONS
SEARCH DETAIL