1.
China Pharmacist ; (12): 1649-1651, 2017.
Article in Chinese | WPRIM | ID: wpr-607399

ABSTRACT

Objective:To establish the quality standard for Herba Euphorbia esulae. Methods:A TLC method was used to identify Herba Euphorbia esulae. An HPLC method was used to determine the content of quercetin with the following conditions: an AlltimaTM C18column(150 mm ×4.6 mm,5 μm) was eluted with the mobile phase of acetonitrile-0.4% phosphoric acid(30 :70), the flow rate was 1. 0 ml·min-1 , the detection wavelength was 360 nm and the column temperature was 35℃. Results:The characteristic spots of samples were the same as those of the standard samples. The linear range of quercetin was 3.194-102.208 μg·ml-1(r=0.9999) and the average recovery was 99. 0% (RSD=1. 68%, n=6). Conclusion:The method is quick, simple and accurate, which can be used for the quality control of Herba Euphorbia esulae.