Rev. bras. anestesiol ; 70(1): 9-14, Jan.-Feb. 2020. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1137140

ABSTRACT

Abstract Background and objectives: Poor monitoring of tracheal tube cuff pressure may result in patient complications. The objective method of using a manometer is recommended to keep safe cuff pressure values (20‒30 cm H2O). However, as manometers are not readily available, anesthesiologists use subjective methods. We aimed to assess appropriateness of a subjective method for attaining cuff pressure and the expertise level of manometer handling among anesthesiology staff and residents in a university teaching hospital. Methods: Prospective observational study, recruiting participants that performed tracheal intubation and the subjective method for tube cuff inflation. Patients with difficult airway, larynx and trachea anatomic abnormality and emergency procedures were not included. Up to 60 minutes after tracheal intubation, an investigator registered the cuff pressure using an aneroid manometer (AMBU®) connected to the tube pilot balloon. Results: Forty-seven anesthesiologists were included in the study - 24 residents and 23 staff. Mean (SD) and medians (IQR) measured in cmH2O were, respectively, 52.5 (27.1) and 50 (30‒70). We registered 83% of measurements outside the recommended pressure range, with no difference between specialists and residents. The level of expertise with the objective method was also similar in both groups. Pressure adjustments were performed in 76.6% of cases. Conclusion: The subjective method for inflating the tracheal tube cuff resulted in a high rate of inadequate cuff pressures, with no difference in performance between anesthesiology specialists and residents.


Resumo Justificativa e objetivos: O controle inadequado da pressão dos balonetes dos tubos traqueais pode resultar em complicações. A técnica objetiva com uso de manômetro é a recomendada para manutenção de valores seguros de pressão (20-30 cm H2O). Mas como ese instrumento é pouco disponível, os anestesiologistas recorrem a técnicas subjetivas. O objetivo deste estudo foi avaliar a adequação da técnica subjetiva para obtenção das pressões dos balonetes e o nível de experiência com uso do manômetro entre médicos especialistas e residentes de anestesiologia de um Hospital Universitário. Método: Estudo observacional prospectivo, com participantes que realizaram intubação traqueal e técnica subjetiva para insuflação dos balonetes. Pacientes com via aérea difícil, anormalidades anatômicas de laringe e traqueia, risco de broncoaspiração e os casos de emergência não foram incluídos. Até 60 minutos após a intubação, um investigador registrava a pressão do balonete utilizando um manômetro aneroide (AMBU®) conectado ao balonete guia do tubo. Resultados: Quarenta e sete anestesiologistas foram incluídos no estudo - 24 residentes e 23 especialistas. As pressões (cm H2O) média (DP) e mediana (IQR) encontradas foram, respectivamente, 52,5 (27,1) e 50 (30-70). Da amostra, 83% estavam fora da faixa adequada de pressão, sem diferença entre especialistas e residentes. O nível de experiência com a técnica objetiva também foi semelhante entre os grupos. Correção da pressão foi realizada em 76,6% dos casos. Conclusões: A técnica subjetiva para insuflar os balonetes dos tubos traqueais resultou em alta prevalência de pressões inadequadas, sem diferença no desempenho entre especialistas e residentes.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Aged , Young Adult , Internship and Residency , Anesthesiology/education , Middle Aged , Prospective Studies , Intubation, Intratracheal/instrumentation , Intubation, Intratracheal/methods
2.
Einstein (Säo Paulo) ; 18: eAO4805, 2020. tab, graf
Article in English | LILACS | ID: biblio-1039729

ABSTRACT

ABSTRACT Objective To simulate different diameters of endotracheal tubes and to verify the fluid dynamics aspects by means of flow and resistance measurements. Methods Fluid dynamics software was used to calculate mean flow and airway resistance in endotracheal tube with a diameter of 6.0, 7.0, 7.5, 8.0, 9.0 and 10.0mm at normal body temperature and under constant pressure. The same measurements were taken in the fusion of the first 22cm of a 9.0mm endotracheal tube with 10.0mm diameter, and with the end part in 12cm of a 6.0mm endotracheal tube with 7.0mm diameter. Results The fusion of the first 22cm of an endotracheal tube of 10.0mm diameter with the terminal part in 12cm of an endotracheal tube of 6.0mm diameter, preserving the total length of 34cm, generated average flow and airway resistance similar to that of a conventional 7.5mm endotracheal tube. Conclusion This simulation study demonstrates that a single-sized endotracheal tube may facilitate endotracheal intubation without causing increased airway resistance.


RESUMO Objetivo Simular diferentes diâmetros de tubos endotraqueais e verificar os aspectos fluidinâmicos, considerando medições de fluxo e resistência. Métodos Foi utilizado um software de fluidinâmica para calcular o fluxo médio e a resistência das vias aéreas nos tubos endotraqueais com diâmetro de 6,0, 7,0, 7,5, 8,0, 9,0 e 10,0mm, em temperatura corporal normal e pressão constante. As mesmas medidas foram realizadas na fusão dos primeiros 22cm de um tubo endotraqueal de 9,0 e 10,0mm de diâmetro, com a parte terminal em 12cm de um tubo endotraqueal de 6,0 e 7,0mm de diâmetro. Resultados A fusão dos primeiros 22cm de um tubo endotraqueal de diâmetro 10,0 mm com a parte terminal em 12cm de um tubo endotraqueal de 6,0mm de diâmetro, preservando o comprimento total de 34cm, gerou fluxo médio e resistência de vias aéreas semelhantes aos de um tubo endotraqueal convencional de 7,5mm. Conclusão Um tubo endotraqueal de tamanho único pode facilitar a intubação endotraqueal, sem causar aumento de resistência na via aérea.


Subject(s)
Computer Simulation , Equipment Design/instrumentation , Intubation, Intratracheal/instrumentation , Respiration, Artificial/instrumentation , Airway Resistance , Intubation, Intratracheal/methods
3.
Rev. bras. anestesiol ; 68(5): 437-441, Sept.-Oct. 2018. tab, graf
Article in English | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-958339

ABSTRACT

Abstract Background and objectives Aortic stenosis is the most common type of heart valve disease. Percutaneous aortic valve replacement has become the alternative for patients considered at high risk for surgery. Controlled mechanical ventilation with tracheal intubation has been the choice for this type of procedure, however the use of noninvasive ventilation in cardiac patients has shown to be beneficial. Janus is a novel full-face mask that allows application of noninvasive ventilation support during anesthesia. Our main objective was to evaluate the feasibility of transcatheter aortic valve replacement with prolonged transesophageal echocardiographic monitoring under deep inhalational sedation delivered through a new mask for noninvasive ventilation. Methods A case series observational study that included five patients with critical aortic stenosis that underwent inhalational anesthesia with sevoflurane for transcatheter aortic valve replacement in a hybrid room of a teaching hospital. Standard monitors and bispectral index were used, followed by inhalational induction and placement of the Janus mask. Anesthesia was maintained with sevoflurane. Patients were transferred to intensive care unit after the procedure. Complications related to the mask use, transesofageal echocardiography accessibility and respiratory implications to the patients were recorded. Results All procedures were uneventful and no major complications were observed intraoperatively. One patient presented CO2 retention (50 mmHg) and sevoflurane leak around the central opening of the mask, both without clinical significance. Conclusions The use of inhalational anesthesia with the facial mask Janus is a safe and efficient alternative to general anesthesia with tracheal intubation for transcatheter aortic valve replacement and can easily accommodate the use of transesophageal echocardiography intraoperatively.


Resumo Justificativa e objetivos A estenose aórtica é o tipo mais comum de doença valvular cardíaca. A substituição percutânea de válvula aórtica tornou-se a alternativa para pacientes cirúrgicos considerados de alto risco. A ventilação mecânica controlada com intubação traqueal tem sido a escolha para esse tipo de procedimento; porém, o uso de ventilação não invasiva em pacientes cardíacos mostrou ser benéfico. Janus é uma nova máscara facial que permite a aplicação de suporte à VNI durante a anestesia. Nosso objetivo primário foi avaliar a viabilidade da substituição transcateter de valva aórtica com monitoração ecocardiográfica transesofágica prolongada sob sedação inalatória profunda através de uma nova máscara para ventilação não invasiva. Métodos Estudo observacional de série de casos que incluiu cinco pacientes com estenose aórtica em fase crítica, submetidos à anestesia inalatória com sevoflurano para substituição transcateter de valva aórtica em uma sala híbrida de um hospital universitário. Monitores padrão e índice bispectral foram usados, seguidos de indução inalatória e colocação da máscara Janus. A anestesia foi mantida com sevoflurano. Os pacientes foram transferidos para a unidade de terapia intensiva após o procedimento. As complicações relacionadas ao uso da máscara, a acessibilidade da ecocardiografia transesofágica e as implicações respiratórias para os pacientes foram registradas. Resultados Todos os procedimentos transcorreram sem incidentes e não foram observadas complicações maiores no intraoperatório. Um paciente apresentou retenção de CO2 (50 mmHg) e vazamento de sevoflurano em torno da abertura central da máscara, ambos sem significância clínica. Conclusões O uso de anestesia inalatória com a máscara facial Janus é uma opção segura e eficiente à anestesia geral com intubação traqueal para substituição transcateter de valva aórtica e pode facilmente acomodar o uso de ecocardiografia transesofágica no intraoperatório.


Subject(s)
Humans , Aortic Valve Stenosis/surgery , Echocardiography, Transesophageal/methods , Transcatheter Aortic Valve Replacement/instrumentation , Intubation, Intratracheal/methods , Adjuvants, Anesthesia
4.
Ribeirão Preto; s.n; 2018. 105 p. ilus.
Thesis in Portuguese | LILACS, BDENF | ID: biblio-1428247

ABSTRACT

O cuidado oral em pacientes intubados internados em Unidade de Terapia Intensiva é uma atividade da Enfermagem que se constitui num conjunto de competências fundamentadas em evidências científicas. A saúde oral refere-se ao ótimo estado da cavidade oral e o bom funcionamento de suas estruturas, obtido por meio da higiene oral adequada, estratégia crucial de prevenção para excluir o risco de problemas bucais e promover o conforto físico e psicológico dos pacientes. A higiene oral inadequada traz vulnerabilidade a cavidade oral potencializando focos de infecções propícias à pneumonia nosocomial. Objetiva identificar e analisar na literatura as melhores evidências disponíveis referentes ao produto, dispositivo e frequência do cuidado oral para prevenção de pneumonia associada à ventilação mecânica em pacientes intubados e em ventilação mecânica internados em Unidade de Terapia Intensiva. Trata-se de uma revisão integrativa da literatura, na qual foi realizada buscas de estudos primários nas bases de dados eletrônicas PubMed, EMBASE e CINAHL, utilizando descritores controlados e os respectivos vocabulários destas bases de dados: MeSh, EMTREE e TÍTULOS. Das 184 referências identificadas, 52 foram selecionados após leitura de título e resumo para serem lidos na íntegra, 18 constituíram a amostra final. A extração e análise dos dados foram realizadas por dois revisores independentes. As publicações dos 18 estudos ocorreram no período de 2009 a 2017. O controle do biofilme e prevenção de lesões na cavidade oral constituem ações importantes para a obtenção da boa saúde oral. Para esse controle, são necessárias intervenções que promovam a remoção mecânica e/ou farmacológica do mesmo. Essas intervenções constituem a combinação de produtos, dispositivos e frequência do cuidado oral. As melhores evidências indicaram a combinação dos seguintes produtos, dispositivos e frequência: creme dental Biotene® combinado com a escovação dentária e também Biotene® enxaguante bucal, para promover a hidratação da cavidade oral, reduzindo a xerostomia; clorexidina 0,12%, melhor evidência como antisséptico; lubrificantes a base de água e hidrossolúveis para mucosa oral e lábios; escova de dentes elétrica de cabeça pequena e cerdas macias, como melhor evidência de dispositivo, porém seu custo pode ser um fator que pode impedir sua larga utilização, em sua indisponibilidade, as evidências apontam para a escova de dentes pediátrica com cerdas macias; raspadores de língua para a remoção do biofilme local; frequência a cada oito horas. Citadas as escalas de avaliação da cavidade oral, sustentando a verificação da saúde oral e como fator determinante da frequência da intervenção, respeitando assim a individualidade do paciente. Recomenda-se implementar o uso de escalas de avaliação da saúde oral para a determinação segura da frequência da intervenção; sugere-se novos estudos que abordem esta temática para comparar as escalas de avaliação da cavidade oral, os produtos, dispositivos e frequência; capacitar os profissionais para que a assistência seja realizada com qualidade e segurança, mitigando eventos adversos aos pacientes


Oral care in intubated patients admitted to an Intensive Care Unit is a nursing activity that is a set of competencies based on scientific evidence. Oral health refers to the excellent state of the oral cavity and the proper functioning of its structures, obtained through proper oral hygiene, a crucial prevention strategy to exclude the risk of oral problems and to promote the physical and psychological comfort of patients. Inadequate oral hygiene brings vulnerability to the oral cavity potentiating foci of infections conducive to nosocomial pneumonia. Aims to identify and analyze, in the literature, the best available evidence regarding the product, device and frequency of oral care for the prevention of pneumonia associated with mechanical ventilation in intubated patients and mechanical ventilation admitted to the Intensive Care Unit. It is an integrative review of the literature, in which searches of primary studies in the electronic databases PubMed, EMBASE and CINAHL were carried out using controlled descriptors and the respective vocabularies of these databases: MeSh, EMTREE and TITLES. Of the 184 references identified, 52 were selected after reading the title and abstract to be read in their entirety, 18 constituted the final sample. Data extraction and analysis were carried out by two independent reviewers. The publications of the 18 studies occurred between 2009 and 2017. Biofilm control and prevention of oral cavity lesions are important actions to achieve good oral health. For this control, interventions that promote the mechanical and / or pharmacological removal of the same are necessary. These interventions are the combination of products, devices and frequency of oral care.The best evidences indicated the combination of the following products, devices and frequency: Biotene® toothpaste combined with toothbrushing and also Biotene® mouthwash, to promote hydration of the oral cavity, reducing xerostomia; chlorhexidine 0.12%, better evidence as an antiseptic; water-based and water-soluble lubricants for oral mucosa and lips; small electric toothbrush and soft bristles, as best evidence of device, however its cost may be a factor that may prevent its wide use, in its unavailability, the evidence points to the pediatric toothbrush with soft bristles; tongue scrapers for local biofilm removal; every eight hours. Cited scales of assessment of the oral cavity, supported the verification of oral health and as a determinant factor of the frequency of intervention, thus respecting the individuality of the patient. It is recommended that the use of oral health assessment scales for the safe determination of the frequency of intervention be implemented; new studies that address this theme are suggest to compare oral cavity evaluation scales, products, devices and frequency; to enable professionals to carry out quality and safe care, mitigating adverse events to patients


Subject(s)
Humans , Respiration, Artificial , Chlorhexidine , Rapid Sequence Induction and Intubation , Intensive Care Units
5.
Rev. bras. anestesiol ; 67(6): 578-583, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-897774

ABSTRACT

Abstract Background Nasogastric tube insertion may be difficult in anesthetized and intubated patients with head in the neutral position. Several techniques are available for the successful insertion of nasogastric tube. The primary aim of this study was to investigate the difference in the first attempt success rate of different techniques for insertion of nasogastric tube. Secondary aim was to investigate the difference of the duration of insertion using the selected technique, complications during insertion such as kinking and mucosal bleeding. Material and methods 200 adult patients, who received general anesthesia for elective abdominal surgeries that required nasogastric tube insertion, were randomized into four groups: Conventional group (Group C), head in the lateral position group (Group L), endotracheal tube assisted group (Group ET) and McGrath video laryngoscope group (Group MG). Success rates, duration of insertion and complications were noted. Results Success rates of nasogastric tube insertion in first attempt and overall were lower in Group C than Group ET and Group MG. Mean duration and total time for successful insertion of NG tube in first attempt were significantly longer in Group ET. Kinking was higher in Group C. Mucosal bleeding was statistically lower in Group MG. Conclusion Use of video laryngoscope and endotracheal tube assistance during NG tube insertion compared with conventional technique increase the success rate and reduce the kinking in anesthetized and intubated adult patients. Use of video laryngoscope during nasogastric tube insertion compared to other techniques reduces the mucosal bleeding in anesthetized and intubated adult patients.


Resumo Justificativa A inserção de sonda nasogástrica (NG) pode ser difícil em pacientes anestesiados e intubados com a cabeça em posição neutra. Há várias técnicas para a inserção bem-sucedida de sonda NG. O objetivo primário deste estudo foi investigar a diferença da taxa de sucesso na primeira tentativa de diferentes técnicas para inserção de sonda NG. O objetivo secundário foi investigar a diferença do tempo de inserção com o uso da técnica selecionada e as complicações durante a inserção (dobradura da sonda e sangramento da mucosa). Material e métodos 200 pacientes adultos que receberam anestesia geral para cirurgias abdominais eletivas que exigiam inserção de sonda NG foram randomicamente distribuídos em quatro grupos: grupo convencional (Grupo C), grupo com a cabeça posicionada lateralmente (Grupo L), grupo com assistência de tubo traqueal (Grupo TE) e grupo com videolaringoscópio McGrath (grupo MG). As taxas de sucesso, os tempos de inserção e as complicações foram registrados. Resultados As taxas de sucesso de inserção da sonda NG na primeira tentativa e em geral foram menores no Grupo C do que nos grupos TE e MG. As durações e os tempos totais de inserção bem-sucedida da sonda NG na primeira tentativa foram significativamente maiores no Grupo TE. Dobradura foi maior no Grupo C. Sangramento da mucosa foi estatisticamente menor no Grupo MG. Conclusão O uso de videolaringoscópio e de TE durante a inserção de sonda NG comparado com o uso da técnica convencional aumentou a taxa de sucesso e reduziu a dobradura da sonda em pacientes adultos anestesiados e intubados. O uso de videolaringoscópio durante a inserção de sonda NG em comparação com outras técnicas reduz o sangramento da mucosa em pacientes adultos anestesiados e intubados.


Subject(s)
Humans , Male , Female , Intubation, Gastrointestinal/methods , Anesthesia , Intubation, Gastrointestinal/adverse effects , Intubation, Intratracheal , Laryngoscopy , Middle Aged
6.
Rev. bras. anestesiol ; 64(1): 66-70, Jan-Feb/2014. tab
Article in Portuguese | LILACS | ID: lil-704236

ABSTRACT

Justificativa e objetivo: especialistas recomendam a intubação traqueal para o manejo das vias aéreas em procedimentos cirúrgicos laparoscópicos. A máscara laríngea (ML) pode ser uma boa opção à intubação endotraqueal. Nesta série de casos, o nosso objetivo foi analisar o uso damáscara laríngea SupremeTM (MLS) na prática cirúrgica laparoscópica. Métodos: o estudo foi conduzido com 60 pacientes, entre 18 e 60 anos, submetidos à cirurgia laparoscópica. Os valores de saturação periférica de O2 (SpO2) e dióxido de carbono no fim da expiração (EtCO2) foram registrados nos minutos um, 15, 30, 45 e 60. A frequência cardíaca e a pressão arterial média (PAM) dos pacientes também foram registradas. Consideramos o tempo de inserção da MLS; a taxa de aplicabilidade da sonda gástrica; a ocorrência de náusea, vômito, tosse e dor de garganta uma hora após a cirurgia. Resultados: a média inicial de EtCO2 foi menor do que aos 15, 30, 45 e 60 minutos (p < 0,0001) e a média de EtCO2 aos 15 minutos foi menor do que nos outros tempos registrados. Observamos que a frequência cardíaca média inicial foi maior do que as subsequentes à inserção da MLS e as anteriores e posteriores à remoção da MLS. A frequência cardíaca média após a inserção da MLS foi acentuadamente menor do que a anterior à remoção da MLS (p = 0,013). A PAM após a inserção da MLS foi menor do que a inicial e também menor do que as anteriores à remoção da MLS (p = 0,0001). Conclusão: a MLS pode ser uma opção adequada para intubação em procedimentos cirúrgicos laparoscópicos em um grupo seleto de pacientes. .


Background and objectives: In laparoscopic surgical procedures, experts recommend tracheal intubation for airway management. Laryngeal mask airway (LMA) can be a good alternative to intubation. In this case series, we aimed to examine the use of the SupremeTM LMA (SLMA) in laparoscopic surgical practice. Methods: We planned the study for sixty patients between the ages of 18 and 60, who would undergo laparoscopic surgery. We recorded one, 15, 30, 45, and 60-minute peripheral O2 saturation (SpO2) and end-tidal carbon dioxide (EtCO2) values, heart rate and mean arterial blood pressure (MAP). We observed the duration of SLMA insertion, the rate of gastric tube applicability, whether nausea, vomiting, and coughing developed, and whether there was postoperative1-hour sore throat. Results: The initial EtCO2 mean was lower than the EtCO2 means of 15, 30, 45, and 60 minutes (p < 0.0001) and the 15-minute EtCO2 mean was lower than other measured EtCO2 means. We observed the initial heart rate mean to be higher than the ones following the SLMA insertion, prior to the SLMA removal, and after the SLMA removal. The heart rate mean after the SLMA insertion was remarkably lower than the heart rate mean prior to the SLMA removal (p = 0.013).The MAP after the SLMA insertion was lower than the initial MAP means, as well as the MAP averages prior to after the removal of SLMA (p = 0.0001). Conclusion: SLMA can be a suitable alternative to intubation in laparoscopic surgical procedures in a group of selected patients. .


Justificativa y objetivo: expertos recomiendan la intubación traqueal para el manejo de las vías aéreas en procedimientos quirúrgicos laparoscópicos. La mascarilla laríngea (ML) puede ser una buena opción a la intubación endotraqueal. En esta serie de casos, nuestro objetivo fue analizar el uso de la mascarilla laríngea SupremeTM (MLS) en la práctica quirúrgica laparoscópica. Métodos: el estudio fue llevado a cabo con la participación de 60 pacientes de entre 18 y 60 anos, sometidos a la cirugía laparoscópica. Los valores de saturación periférica de O2 (SpO2) y de dióxido de carbono al final de la espiración (EtCO2), fueron registrados en los minutos 1, 15, 30, 45 y 60. La frecuencia cardíaca y la presión arterial promedio (PAP) de los pacientes también fueron registradas. Consideramos el tiempo de inserción de la MLS; así como la tasa de aplicabilidad de la sonda gástrica, el aparecimiento de nóusea, vómito, tos y dolor de garganta una hora después de la operación. Resultados: el promedio inicial de EtCO2 fue menor que a los 15, 30, 45 y 60 minutos (p < 0,0001) y el promedio de EtCO2 a los 15 minutos fue menor que en los otros tiempos registrados. Observamos que la frecuencia cardíaca promedio inicial fue mayor que las posteriores a la inserción de la MLS y a las anteriores, y posteriores a la retirada de la MLS. La frecuencia cardíaca promedio después de la inserción de la MLS fue acentuadamente menor que la anterior a la retirada de la MLS (p = 0,013). La PAP después de la inserción de la MLS fue menor que la inicial y también menor que las anteriores a la retirada de la MLS (p = 0,0001). Conclusiones: la MLS puede ser una opción adecuada para la intubación en los procedimientos quirúrgicos laparoscópicos en ...


Subject(s)
Adolescent , Adult , Female , Humans , Male , Intubation, Intratracheal/methods , Laryngeal Masks , Arterial Pressure , Carbon Dioxide/metabolism , Heart Rate , Laparoscopy
7.
Rev. bras. anestesiol ; 63(5): 419-421, set.-out. 2013. tab
Article in Portuguese | LILACS | ID: lil-691377

ABSTRACT

Paciente do sexo masculino, 56 anos, apresentou-se para excisão de glioblastoma intracraniano multiforme. Após ser rotineiramente monitorado, o paciente foi pré-oxigenado. Anestesia e paralisia foram induzidas com propofol (200 mg), fentanil (50 µg) e vecurônio (9 mg). Laringoscopia direta com lâmina Macintosh número 3 revelou um cisto pedunculado de 2x2 cm, que surgia do lado direito da valécula e impedia a intubação endotraqueal. Enquanto o paciente permanecia anestesiado, consultamos rapidamente um otorrinolaringologista e o cisto foi aspirado por uma seringa com agulha de calibre 22G sob laringoscopia direta. Aspiramos 10 cc de líquido. Intubação traqueal foi feita em seguida sem intercorrências com sonda de 9,0 aramada e com balão. Uma opção para a intubação com fibra óptica pode ser a aspiração cuidadosa do cisto para facilitar a intubação.


A 56-year-old man presented himself for an intracranial glioblastoma multiforme excision. After being routinely monitored, he was preoxygenated. We induced anesthesia and paralysis with 200 mg propofol, 50 µg fentanyl and 9 mg vecuronium. Direct laryngoscopy with a Macintosh 3 blade revealed a 2x2 cm cyst, pedunculated, arising from the right side of the vallecula preventing the endotracheal intubation. While the patient remained anesthetized, we urgently consulted an otolaryngologist and aspirated the cyst with a 22-gauge needle and syringe under direct laryngoscopy. We aspirated 10 cc of liquid content. This was followed by an uneventful tracheal intubation with a 9.0 enforced spiral cuffed tube. An alternative to fiberoptic intubation may be careful cyst aspiration to facilitate the intubation.


Un paciente del sexo masculino, de 56 años, llegó para una resección de glioblastoma intracraneal multiforme. Posteriormente a la rutina de monitorización, el paciente fue pre-oxigenado. La anestesia y la parálisis se indujeron con propofol (200 mg), fentanilo (50 µg) y vecuronio (9 mg). La laringoscopia directa con lámina 3 Macintosh arrojó un quiste pedunculado de 2x2 cm que surgía al lado derecho de la valécula e impedía la intubación endotraqueal. Mientras el paciente permanecía anestesiado, consultamos rápidamente un otorrinolaringólogo y el quiste fue aspirado por una jeringa con una aguja calibre 22G bajo laringoscopia directa. Aspiramos 10 cc de líquido. La intubación traqueal se hizo enseguida sin intercurrencias con una sonda de 9,0 y un alambre en espiral y con balón. Una opción para la intubación con fibra óptica puede ser la aspiración cuidadosa del quiste para facilitar la intubación.


Subject(s)
Aged , Humans , Male , Anesthesia , Cysts/complications , Cysts/surgery , Laryngeal Diseases/complications , Brain Neoplasms/complications , Brain Neoplasms/surgery , Glioblastoma/complications , Glioblastoma/surgery , Intubation, Intratracheal , Suction
8.
Rev. bras. anestesiol ; 63(4): 359-362, jul.-ago. 2013. tab
Article in Portuguese | LILACS | ID: lil-680146

ABSTRACT

JUSTIFICATIVA E OBJETIVO: Descrever um protocolo de intubação com broncoscópio flexível (FBI, de flexible bronchoscopy intubation) em pacientes com via aérea difícil, sua eficácia e segurança. MÉTODOS: Foram revisados os prontuários médicos de pacientes diagnosticados com via aérea difícil que foram submetidos à broncoscopia flexível para intubação sob ventilação espontânea e sedação com midazolam e fentanil, de março de 2009 a dezembro de 2010. RESULTADOS: Foram selecionados 102 pacientes, 69 (67,7%) homens e 33 (32,3%) mulheres, com idade média de 44 anos. Em 59 pacientes com via aérea difícil prevista (57,8%) a FBI foi feita em centro cirúrgico; 39 (38,2%) ocorreram na Unidade de Terapia Intensiva e quatro casos (3,9%) na sala de emergência. Tosse, queda transitória de saturação de oxigênio e dificuldade de progredir a cânula através da laringe foram as principais complicações do método, mas não impediram a intubação. CONCLUSÃO: A FBI seguindo protocolo de sedação consciente com midazolam e fentanil é eficiente e segura no manejo de pacientes com via aérea difícil.


BACKGROUND AND OBJECTIVE: To describe the effi cacy and safety of a fl exible bronchoscopy intubation (FBI) protocol in patients with diffi cult airway. METHOD: We reviewed the medical records of patients diagnosed with diffi cult airway who underwent fl exible bronchoscopy intubation under spontaneous ventilation and sedation with midazolam and fentanyl from March 2009 to December 2010. RESULTS: The study enrolled 102 patients, 69 (67.7%) men and 33 (32.3%) women, with a mean age of 44 years. FBI was performed in 59 patients (57.8%) with expected diffi cult airway in the operating room, in 39 patients (38.2%) in the Intensive Care Unit (ICU), and in 4 patients (3.9%) in the emergency room. Cough, decrease in transient oxygen saturation, and diffi cult progression of the cannula through the larynx were the main complications, but these factors did not prevent intubation. CONCLUSION: FBI according to the conscious sedation protocol with midazolam and fentanyl is effective and safe in the management of patients with diffi cult airway.


JUSTIFICATIVA Y OBJETIVO: Describir un protocolo de intubación con broncoscopio fl exible (FBI, de flexible bronchoscopy intubation) en pacientes con la vía aérea difícil, su eficacia y seguridad. MÉTODOS: Describir un protocolo de intubación con broncoscopio fl exible (FBI, de flexible bronchoscopy intubation) en pacientes con la vía aérea difícil, su efi cacia y se Se revisaron las historias clínicas de pacientes diagnosticados con vía aérea difícil y que fueron sometidos a la broncoscopia fl exible para la intubación bajo ventilación espontánea y sedación con midazolam y fentanilo, de marzo de 2009 a diciembre de 2010. RESULTADOS: Fueron seleccionados 102 pacientes, 69 (67,7%) hombres y 33 (32,3%) mujeres, con una edad promedio de 44 años. En 59 pacientes con vía aérea difícil prevista (57,8%) la FBI se hizo en un centro quirúrgico; 39 (38,2%) ocurrieron en la Unidad de Cuidados Intensivos y cuatro casos (3,9%) en la sala de emergencia. La tos, la caída de saturación de oxígeno transitoria y la difi cultad para insertar la cánula a través de la laringe, fueron las principales complicaciones del método, pero no impidieron la intubación. CONCLUSIONES: La FBI, si secunda un protocolo de sedación consciente con midazolam y fentanilo, es efi ciente y segura en el manejo de pacientes con vía aérea difícil.


Subject(s)
Adult , Female , Humans , Male , Airway Management/methods , Bronchoscopes , Intubation, Intratracheal/methods , Airway Management/instrumentation , Equipment Design , Retrospective Studies
9.
Rev. bras. anestesiol ; 63(3): 235-244, maio-jun. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-675838

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Investigar o efeito de esmolol, lidocaína e fentanil na dispersão da onda P (DP), durações dos intervalos QT e QT corrigido (QTc) e as respostas hemodinâmicas à intubação endotraqueal durante a indução com propofol. MÉTODOS: Foram incluídos 80 pacientes adultos, estado físico ASA I ou II, idade entre 18 e 60 anos, neste estudo prospectivo, randômico e duplo-cego. Todos os pacientes foram submetidos a exame eletrocardiográfico (ECG) antes da indução da anestesia. Os pacientes foram randomicamente alocados em quatro grupos iguais. O grupo controle (Grupo C) recebeu 5 mL de solução salina; o grupo esmolol (Grupo E) recebeu 0,5 mg.kg-1 de esmolol; o grupo fentanil (Grupo F) recebeu 2 µg.kg-1 de fentanil e o grupo lidocaína (Grupo L) recebeu 1,5 mg.kg-1 de lidocaína antes da indução anestésica. A anestesia foi induzida com propofol. ECG foi feito em todos os pacientes durante o primeiro e o terceiro minutos de indução, 3 minutos após a administração de relaxante muscular e 5 e 10 minutos após intubação. A DP e intervalos QT foram medidos em todos os ECGs. Os intervalos QTc foram determinados com o uso da fórmula de Bazett. Frequência cardíaca (FC) e pressão arterial média (PAM) foram registradas antes e depois da indução anestésica, imediatamente após a intubação e em 1, 3, 5, 7 e 10 minutos após a intubação. RESULTADOS: Após a intubação, a FC aumentou significativamente nos Grupos C, L e F em comparação com o grupo controle. Porém, não houve diferença significativa nos valores da FC após a intubação entre os grupos E e controle. Nos Grupos C e L, a PAM aumentou significativamente após a intubação em comparação com o grupo controle. No entanto, nos Grupos L, F e E não houve diferença significativa entre os valores da PAM após a intubação em comparação com o grupo controle. A DP foi significativamente mais longa no Grupo C após a intubação em comparação com o grupo controle. Porém, nos grupos L, F e E não houve diferença significativa entre os valores de DP após a intubação em comparação com o grupo controle. A duração do intervalo QTc foi significativamente maior nos grupos C e L após a intubação em comparação com o grupo controle. Porém, não houve diferença significativa na duração do QTc nos grupos F e E após a intubação em comparação com o grupo controle. CONCLUSÃO: Concluímos que a administração de esmolol antes da intubação previne a taquicardia, o aumento da PAM e as durações da onda P e intervalo QTc causados pela laringoscopia e intubação traqueal.


BACKGROUND AND OBJECTIVES: In our study we aimed to investigate the effect of esmolol, lidocaine and fentanyl on P-wave dispersion (Pwd), QT and corrected QT (QTc) durations and hemodynamic responses to endotracheal intubation during propofol induction. METHODS: A total of eighty adult patients, American Society of Anesthesiologists (ASA) Physical Status I or II aged 18 to 60 years were included in this prospective, randomised, double-blind study. All patients had control electrocardiograms (ECGs) done before anesthesia induction. The patients were randomised into four equal groups. The control group (Group C) received saline 5 mL, the esmolol group (Group E) received esmolol 0.5 mg.kg-1, the fentanyl group (Group F) received fentanyl 2 µg.kg-1 and the lidocaine group (Group L) received lidocaine 1.5 mg.kg-1 before anesthesia induction. Anesthesia was induced with intravenous propofol. ECGs for all patients were performed during the 1st and 3rd minutes of induction, 3 minutes after administration of muscle relaxant, and at 5 minutes and 10 minutes after intubation. Pwd and QT intervals were measured on all ECGs. QTc intervals were determined using the Bazett formula. Heart rate (HR) and mean arterial pressure (MAP) were recorded before and after induction of anesthesia, immediately after intubation, and 1, 3, 5, 7 and 10 minutes after intubation. RESULTS: Compared with control, HR significantly increased in Group C, Group L and Group F after intubation. However, in Group E, there was no significant difference in HR values between control and after intubation. Compared with control, MAP significantly increased in Group C and Group L after the intubation. However, in Group E and Group F, there was no significant difference in MAP values between control and after the intubation. Compared with control, Pwd significantly increased in Group C after intubation. In Group L, Group F and Group E, there was no significant difference in Pwd values between control and after the intubation. Compared with control, QTc duration significantly increased in Group C and L after the intubation. In Group F and Group E, there was no significant difference in QTc durations between control and after the intubation. CONCLUSION: We concluded that administration of esmolol before intubation prevents tachycardia and an increase in MAP, Pwd and QTc duration caused by laryngoscopy and tracheal intubation.


JUSTIFICATIVA Y OBJETIVOS: Investigar el efecto del esmolol, lidocaína y fentanilo en la dispersión de la onda P (DOP), duraciones de los intervalos QT y QT corregido (QTc) y las respuestas hemodinámicas a la intubación endotraqueal durante la inducción con propofol. MÉTODOS: En este estudio prospectivo, aleatorio y doble ciego, fueron incluidos 80 pacientes adultos, con estado físico ASA I o II, y edad entre 18 y 60 años. Todos los pacientes se sometieron al examen electrocardiográfico (ECG) antes de la inducción de la anestesia. Los pacientes fueron aleatoriamente divididos en cuatro grupos iguales. El grupo control (Grupo C) recibió 5 mL de solución salina; el grupo esmolol (Grupo E) recibió 0,5 mg.kg-1 de esmolol; el grupo fentanilo (Grupo F) recibió 2 µg.kg-1 de fentanilo y el grupo lidocaína (Grupo L) recibió 1,5 mg.kg-1 de lidocaína antes de la inducción anestésica. La anestesia fue inducida con propofol. El ECG se hizo en todos los pacientes durante el primero y el tercer minuto de inducción, 3 minutos después de la administración del relajante muscular y 5 y 10 minutos después de la intubación. La DOP y los intervalos QT se midieron en todos los ECGs. Los intervalos QTc fueron determinados con el uso de la fórmula de Bazett. La frecuencia cardíaca (FC) y la presión arterial promedio (PAP) fueron registradas antes y después de la inducción anestésica, inmediatamente después de la intubación y en 1, 3, 5, 7 y 10 minutos después de la intubación. RESULTADOS: Después de la intubación, la FC aumentó significativamente en los Grupos C, L y F en comparación con el grupo control. Sin embargo, no hubo diferencia significativa en los valores de la FC después de la intubación entre los grupos E y control. En los Grupos C y L, la PAP aumentó significativamente después de la intubación en comparación con el grupo control. Sin embargo, en los Grupos L, F y E no hubo diferencia significativa entre los valores de la PAP posteriormente a la intubación en comparación con el grupo control. La DOP fue significativamente más larga en el Grupo C después de la intubación en comparación con el grupo control. No obstante, en los grupos L, F y E no hubo diferencia significativa entre los valores de DOP después de la intubación en comparación con el grupo control. La duración del intervalo QTc fue significativamente mayor en los grupos C y L después de la intubación en comparación con el grupo control. Sin embargo, no hubo diferencia significativa en la duración del QTc en los grupos F y E después de la intubación en comparación con el grupo control. CONCLUSIONES: Llegamos entonces a la conclusión, de que la administración del esmolol antes de la intubación previene la taquicardia, el aumento de la PAP y las duraciones de la onda P e intervalo QTc causados por la laringoscopia y por la intubación traqueal.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Young Adult , Adrenergic beta-1 Receptor Antagonists/pharmacology , Anesthetics, Intravenous/pharmacology , Anesthetics, Local/pharmacology , Electrocardiography/drug effects , Fentanyl/pharmacology , Hemodynamics/drug effects , Intubation, Intratracheal , Lidocaine/pharmacology , Propanolamines/pharmacology , Propofol/pharmacology , Double-Blind Method , Prospective Studies
10.
Rev. bras. anestesiol ; 63(3): 262-266, maio-jun. 2013. tab
Article in Portuguese | LILACS | ID: lil-675843

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Apesar da semelhante incidência de dificuldade à laringoscopia em obesos e não obesos há mais relatos de dificuldade de intubação endotraqueal em portadores de obesidade. Alternativas de diagnóstico e previsão de dificuldade de intubação no pré-operatório podem ajudar diminuir complicações anestésicas em indivíduos obesos. O objetivo do estudo foi identificar preditores para diagnóstico de via aérea difícil em pacientes obesos, pela correlação com métodos clínicos de avaliação pré-anestésica e polissonografia. Comparou-se também a incidência de dificuldade à ventilação sob máscara facial e à laringoscopia entre obesos e não obesos, verificando os preditores mais prevalentes. MÉTODOS: Estudo observacional, prospectivo, comparativo, com 88 pacientes adultos, submetidos à anestesia geral. No período pré-operatório, avaliou-se questionário sobre preditores clínicos de síndrome da apneia obstrutiva do sono (SAOS) e parâmetros anatômicos. Durante a anestesia, pesquisou-se dificuldade à ventilação sob máscara facial e laringoscopia. Para análise, estatística descritiva e teste de correlação. RESULTADOS: Os pacientes foram alocados em dois grupos, 43 obesos e 45 não obesos. Estado físico, prevalência de roncos, hipertensão e diabetes mellitus, circunferência cervical e índice de Mallampati foram maiores nos obesos. Pacientes obesos apresentaram maior incidência de dificuldade de ventilação sob máscara e laringoscopia. Nenhuma variável clínica ou anatômica apresentou correlação com dificuldade de ventilação sob máscara nos grupos. Nos obesos, o diagnóstico de SAOS mostrou forte correlação com dificuldade à laringoscopia. CONCLUSÕES: Os diagnósticos clínico e polissonográfico de SAOS se mostraram úteis no diagnóstico pré-operatório de dificuldade à laringoscopia. Pacientes obesos estão mais propensos à dificuldade de ventilação sob máscara e laringoscopia.


BACKGROUND AND OBJECTIVES: Although the incidence of difficult laryngoscopy is similar in obese and non-obese patients, there are more reports of difficult intubation in obese individuals. Alternatives for the diagnosis and prediction of difficult intubation in the preoperative period may help reduce anesthetic complications in obese patients. The aim of this study was to identify predictors for the diagnosis of difficult airway in obese patients, correlating with the clinical methods of pre-anesthetic evaluation and polysomnography. We also compared the incidence of difficult facemask ventilation and difficult laryngoscopy between obese and non-obese patients, identifying the most prevalent predictors. METHODS: Observational, prospective and comparative study, with 88 adult patients undergoing general anesthesia. In the preoperative period, we evaluated a questionnaire on the clinical predictors of the obstructive sleep apnea syndrome (OSAS) and anatomical parameters. During anesthesia, we evaluated difficult facemask ventilation and laryngoscopy. Descriptive statistics and correlation test were used for analysis. RESULTS: Patients were allocated into two groups: obese group (n = 43) and non-obese group (n = 45). Physical status, prevalence of snoring, hypertension, diabetes mellitus, neck circumference, and Mallampati index were higher in the obese group. Obese patients had a higher incidence of difficult facemask ventilation and laryngoscopy. There was no correlation between anatomical or clinical variable and difficult facemask ventilation in both groups. In obese patients, the diagnosis of OSAS showed strong correlation with difficult laryngoscopy. CONCLUSIONS: The clinical and polysomnographic diagnosis of OSA proved useful in the preoperative diagnosis of difficult laryngoscopy. Obese patients are more prone to difficult facemask ventilation and laryngoscopy.


JUSTIFICATIVA Y OBJETIVOS: A pesar de la incidencia similar de dificultad a la laringoscopia en obesos y no obesos, existen relatos de dificultad de intubación endotraqueal en obesos. Alternativas de diagnóstico y previsión de dificultad de intubación en el preoperatorio pueden ayudar a disminuir las complicaciones anestésicas en los individuos obesos. El objetivo del estudio fue identificar los predictores para el diagnóstico de la vía aérea difícil en pacientes obesos, por medio de la correlación con los métodos clínicos de evaluación preanestésica y la polisomnografía. También comparamos la incidencia de dificultad a la ventilación bajo mascarilla facial y a la laringoscopia entre obesos y no obesos, verificando los predictores más prevalentes. MÉTODOS: Estudio observacional, prospectivo y comparativo con 88 pacientes adultos, sometidos a la anestesia general. En el período preoperatorio, se evaluó el cuestionario sobre predictores clínicos del síndrome de la apnea obstructiva del sueño (SAOS) y los parámetros anatómicos. Durante la anestesia, investigamos una dificultad para la ventilación bajo mascarilla facial y laringoscopia. Para el análisis, la estadística descriptiva y el test de correlación. RESULTADOS: Los pacientes fueron ubicados en dos grupos, 43 obesos y 45 no obesos. El estado físico, la prevalencia de ronquidos, la hipertensión, la diabetes mellitus, la circunferencia cervical y le índice de Mallampati fueron más elevados en los obesos. Los pacientes obesos tenían una mayor incidencia de dificultad de ventilación bajo mascarilla y laringoscopia. Ninguna variable clínica o anatómica tuvo correlación con la dificultad de ventilación bajo mascarilla en los grupos. En los obesos, el diagnóstico de SAOS arrojó una fuerte correlación con la dificultad a la laringoscopia. CONCLUSIONES: Los diagnósticos clínico y polisomnográfico de SAOS fueron útiles para el diagnóstico preoperatorio de dificultad a la laringoscopia. Los pacientes obesos son más propensos a la dificultad de ventilación bajo mascarilla y laringoscopia.


Subject(s)
Female , Humans , Male , Middle Aged , Intubation, Intratracheal , Obesity , Preoperative Care/methods , Obesity/complications , Prospective Studies
11.
Rev. bras. anestesiol ; 63(1): 110-112, jan.-fev. 2013. ilus
Article in Portuguese | LILACS | ID: lil-666123

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Relatamos um caso de pneumotórax causado por perfuração brônquica durante uma reintubação usando um cateter para troca da via aérea (CTVA) em um paciente com câncer de cabeça e pescoço. RELATO DE CASO: Paciente do sexo masculino, 53 anos, com carcinoma de orofaringe, foi internado na UTI com pneumonia grave e síndrome da angústia respiratória aguda (SARA). O paciente foi identificado como sendo de difícil intubação e uma sonda endotraqueal (SET) foi inserida através de um broncoscópio. Após uma semana de tratamento, observou-se ruptura do manguito endotraqueal. A troca da sonda endotraqueal foi necessária para obter uma ventilação pulmonar satisfatória. Um cateter para troca da via aérea (Cook, tamanho 14) foi usado para realizar a reintubação. Depois da reintubação, o paciente apresentou piora na saturação de oxigênio e uma radiografia revelou um grande pneumotórax. Um dreno torácico foi inserido e uma melhora imediata na saturação de oxigênio foi observada. A repetição da radiografia confirmou o posicionamento correto do dreno torácico e a reexpansão do pulmão direito. A broncoscopia realizada mostrou uma laceração posterior do brônquio principal direito. O paciente foi extubado no dia seguinte. Depois de quatro dias, o dreno torácico foi removido. A radiografia realizada um dia depois da retirada do dreno revelou um pequeno pneumotórax no lobo superior direito, mas o paciente permaneceu assintomático. CONCLUSÕES: O cateter para troca da via aérea é uma ferramenta valiosa para lidar com pacientes difíceis de intubar. Embora os médicos geralmente concentrem sua atenção em evitar um barotrauma causado pelo suplemento de oxigênio ou ventilação a jato através do CTVA, a preocupação com a técnica de inserção pode minimizar as complicações que ameaçam a vida e aumentar a segurança do CTVA.


BACKGROUND AND OBJECTIVES: We report a case of pneumothorax caused by a bronchial perforation during a reintubation using an airway exchange catheter (AEC) in a patient with a head and neck cancer. CASE REPORT: A 53 year old man with oropharynx carcinoma was admitted to ICU for severe pneumonia and severe acute respiratory distress syndrome (ARDS). The patient was recognized as a difficult-to-intubate patient and an endotracheal tube (ETT) was inserted through a bronchoscope. After one week of treatment, it was observed an endotracheal cuff perforation. Exchanging the endotracheal tube was necessary to achieve satisfactory pulmonary ventilation. An AEC Cook 14 was used to perform the reintubation. After reintubation, the patient presented a worsening in oxygen saturation and a chest radiography (CXR) revealed a large pneumothorax. A chest tube was inserted and we observed immediate improvement in oxygen saturation. A repeat CXR confirmed correct positioning of the chest tube and reexpansion of the right lung. A bronchoscopy performed showed a posterior laceration in the right main bronchus. The patient was extubated the following day. After four days, the chest tube was removed. A CXR performed a day after chest tube removal revealed a small right upper pneumothorax, but the patient remained asymptomatic. CONCLUSIONS: Airway exchange catheter is a valuable tool to handle with difficult-to-intubate patients. Although the physicians generally focus their attention in avoid barotrauma - caused by oxygen supplement or jet ventilation through AEC - concern for insertion technique can minimize life threatening complications and increase the safety of AEC.


JUSTIFICATIVA Y OBJETIVOS: Relatamos aquí un caso de neumotórax causado por perforación brónquica durante una reintubación usando un catéter para el cambio de la vía aérea (CTVA) en una paciente con cáncer de cabeza y cuello. RELATO DE CASO: Paciente del sexo masculino, 53 años, con carcinoma de orofaringe, que fue ingresado en la UTI con neumonía grave y el síndrome de la angustia respiratoria aguda (SARA). El paciente fue identificado como siendo de difícil intubación y con un broncoscopio se le insertó una sonda endotraqueal (SET). Después de una semana de tratamiento, vimos una ruptura del manguito endotraqueal. El cambio de la sonda endotraqueal se hizo necesario para obtener una ventilación pulmonar satisfactoria. Un catéter para el cambio de la vía aérea (Cook, tamaño 14) se usó para realizar la reintubación. Después de la reintubación, el paciente tuvo un empeoramiento en la saturación de oxígeno y una radiografía reveló un fuerte neumotórax. Un dreno torácico se insertó observando una mejoría inmediata en la saturación de oxígeno. La repetición de la radiografía confirmó el posicionamiento correcto del dreno torácico y la re-expansión del pulmón derecho. La broncoscopia realizada arrojó una laceración posterior del bronquio principal derecho. El paciente se desentubó al día siguiente. Después de cuatro días, el dreno torácico se retiró. La radiografía realizada un día después de la retirada del dreno reveló un pequeño neumotórax en el lóbulo superior derecho, pero el paciente permaneció asintomático. CONCLUSIONES: El catéter para el cambio de la vía aérea es una herramienta valiosa para lidiar con los pacientes difíciles de intubar. Aunque los médicos generalmente concentren su atención en evitar un barotrauma causado por el suplemento de oxígeno o ventilación a chorro por medio del CTVA, la preocupación con la técnica de inserción puede minimizar las complicaciones que amenazan la vida y aumentar la seguridad del CTVA.


Subject(s)
Humans , Male , Middle Aged , Bronchi/injuries , Chest Tubes/adverse effects , Intubation, Intratracheal/adverse effects , Intubation, Intratracheal/instrumentation , Pneumothorax/etiology , Retreatment
12.
Rev. bras. anestesiol ; 62(6): 793-798, nov.-dez. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-659010

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A intubação traqueal associada a operações das vias aéreas faz com que complicações como laringoespasmo, broncoespasmo e períodos de redução da saturação de oxigênio sejam frequentemente relatados em adenotonsilectomias, procedimento que, por sua natureza, eleva a incidência de tais complicações. O objetivo deste estudo foi analisar a ocorrência de problemas respiratórios comparando-se o uso da máscara laríngea (ML) descartável com a intubação orotraqueal em adenotonsilectomias. MÉTODOS: Foram avaliados 204 pacientes pediátricos submetidos a anestesia geral para adenotonsilectomias e alocados em dois grupos, aleatoriamente: grupo Cânula Traqueal (CT, n = 100) e grupo Máscara Laríngea (ML, n = 104). Foram observados os níveis de saturação de pulso de oxigênio (SpO2) após a indução anestésica (SpO2-1), após o estabelecimento de campo operatório (SpO2-2), ao término do procedimento cirúrgico (SpO2-3), três minutos após a retirada do dispositivo respiratório (SpO2-4) e na admissão da sala de recuperação anestésica (SpO2-5). As complicações respiratórias foram relatadas. RESULTADOS: Os valores médios e os desvios padrão de SpO2 nos grupos CT e ML foram, respectivamente: SpO2-1: 98,9 ± 1,0 e 98,7 ± 0,8 (p > 0,25); SpO2-2: 97,4 ± 1,0 e 94,9 ± 4,3 (p < 0,001); SpO2-3: 96,9 ± 1,1 e 97,2 ± 1,1 (p = 0,037); SpO2-4: 91,7 ± 9,0 e 95,2 ± 2,2 (p < 0,001); SpO2-5: 94,0 ± 2,1 e 95,8 ± 2,6 (p < 0,001). No grupo ML, em 12 pacientes, foi necessária alguma manobra para ajuste do dispositivo e correção de vazamento durante o ato operatório. A ML foi substituída pela CT em quatro pacientes. As complicações respiratórias foram similares entre os grupos. CONCLUSÕES: Adenotonsilectomias em pacientes pediátricos com o emprego da ML, em comparação com a CT, resulta em menores valores de SpO2 intraoperatórios e, eventualmente, necessidade de substituição da ML pela CT. Apesar de a ML viabilizar a cirurgia, pela segurança, o uso da CT é preferível.


BACKGROUND AND OBJECTIVES: Tracheal intubation associated with airway operations can cause complications such as laryngospasm, bronchospasm and periods of reduced oxygen saturation. Such complications are frequently reported during adenotonsillectomies, a procedure that by nature increases the incidence of airway complications. The objective of this study was to compare the occurrence of respiratory problems during adenotonsillectomies while using either a disposable laryngeal mask airway (LMA) or an endotracheal tube (TT). METHODS: We evaluated 204 pediatric patients undergoing general anesthesia for adenotonsillectomies. The patients were randomly allocated into either the tracheal intubation group (TT, n = 100) or the laryngeal mask airway group (LMA, n = 104). It was measured the level of oxygen saturation by pulse oximetry (SpO2) after the induction of anesthesia (SpO2-1), after establishing the operative field (SpO2-2), at the end of the surgical procedure (SpO2-3), three minutes after the removal of the contained breathing apparatus (SpO2-4) and upon admission to the post-anesthesia care unit (SpO2-5). All respiratory complications were recorded. RESULTS: The mean SpO2 values and standard deviations for the TT and LMA groups were as follows: SpO2-1: 98.9 ± 1.0 and 98.7 ± 0.8 (p > 0.25), SpO2-2: 97.4 ± 1.0 and 94.9 ± 4.3 (p < 0.001), SpO2-3: 96.9 ± 1.1 and 97.2 ± 1.1 (p = 0.037), SpO2-4: 91.7 ± 9.0 and 95.2 ± 2.2 (p < 0.001) and SpO2-5: 94.0 ± 2.1 and 95.8 ± 2.6 (p < 0.001), respectively. In the LMA group, 12 patients required some maneuvering to fix positioning and leaks during surgery. In four patients, the LMA had to be replaced with a TT. Respiratory complications were similar between groups. CONCLUSIONS: Performing adenotonsillectomies in pediatric patients using a LMA resulted in a lower intraoperative SpO2, compared to using a TT. In some cases, the LMA had to be replaced with an endotracheal tube. Although the surgery may be performed with LMA, the use of a TT is preferred for safety.


JUSTIFICATIVA Y OBJETIVOS: La intubación traqueal asociada con las operaciones de las vías aéreas hace con que complicaciones como el laringoespasmo, el broncoespasmo y los períodos de reducción de la saturación de oxígeno sean a menudo relatados en adenotonsilectomías, procedimiento que, por su naturaleza, eleva la incidencia de tales complicaciones. El objetivo de este estudio, fue analizar la aparición de problemas respiratorios comparándose el uso de la mascarilla laríngea (ML) desechable con la intubación orotraqueal en adenotonsilectomías. MÉTODOS: Se evaluaron 204 pacientes pediátricos sometidos a la anestesia general para las adenotonsilectomías que se dividieron en dos grupos aleatoriamente: grupo Cánula Traqueal (CT, n = 100) y grupo Mascarilla Laríngea (ML, n = 104). Se observaron los niveles de saturación de pulso de oxígeno (SpO2) después de la inducción anestésica (SpO2-1), posteriormente al establecimiento del campo operatorio (SpO2-2), al término del procedimiento quirúrgico (SpO2-3), tres minutos después de la retirada del dispositivo respiratorio (SpO2-4) y a la llegada a la sala de recuperación anestésica (SpO2-5). Las complicaciones respiratorias se relataron. RESULTADOS: Los valores promedios y las desviaciones estándar de SpO2 en los grupos CT y ML fueron, respectivamente: SpO2-1: 98,9 ± 1,0 y 98,7 ± 0,8 (p > 0,25); SpO2-2: 97,4 ± 1,0 y 94,9 ± 4,3 (p < 0,001); SpO2-3: 96,9 ± 1,1 y 97,2 ± 1,1 (p = 0,037); SpO2-4: 91,7 ± 9,0 y 95,2 ± 2,2 (p < 0,001); SpO2-5: 94,0 ± 2,1 y 95,8 ± 2,6 (p < 0,001). En el grupo ML, en 12 pacientes, se necesitó alguna maniobra para el ajuste del dispositivo y para la corrección del escape durante la operación. La ML se remplazó por la CT en cuatro pacientes. Las complicaciones respiratorias fueron similares entre los grupos. CONCLUSIONES: La realización de adenotonsilectomías en pacientes pediátricos con el uso de la ML, en comparación con la CT, acarrea menores valores de SpO2 intraoperatorios y eventualmente la necesidad de sustitución de la ML por la CT. A pesar de que la ML viabiliza la realización de la cirugía, en razón de la seguridad, se prefiere el uso de la CT.


Subject(s)
Child , Child, Preschool , Female , Humans , Male , Adenoidectomy , Intraoperative Complications/etiology , Laryngeal Masks/adverse effects , Respiration Disorders/etiology , Tonsillectomy , Anesthesia , Disposable Equipment , Intubation, Intratracheal/adverse effects
13.
Rev. bras. anestesiol ; 62(5): 733-735, set.-out. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-649554

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: O desenvolvimento de hematoma retrofaríngeo após trauma contuso é uma ocorrência rara. Porém, uma lesão ocupando espaço nessa área pode ser fatal, o que exige rápida avaliação e tratamento. Esse tipo de hematoma é clinicamente importante devido à proximidade entre o espaço retrofaríngeo e a via aérea superior. Qualquer edema nesse espaço pode causar uma protuberância da parede posterior da faringe de encontro às vias aéreas e obstruí-las. RELATO DE CASO: Paciente do sexo feminino, 86 anos, que caiu de uma altura de 1,5 m e bateu o pescoço na escada, foi admitida em nosso Departamento de Traumatologia. Tomografia computadorizada e radiografia dos tecidos moles do pescoço foram feitas e mostraram uma grande massa retrofaríngea que se estendia da base do crânio até o nível dos pulmões. A paciente ficou em observação e o tamanho do hematoma diminuiu espontaneamente nos sete dias subsequentes; contudo, devido a uma infecção pulmonar, a paciente foi a óbito no décimo dia. Este relato enfatiza que a drenagem precoce do hematoma retrofaríngeo poderia ter sido considerada neste caso. Embora seja de ocorrência rara, o hematoma retrofaríngeo é um problema que pode ser encontrado em serviços de emergência.


BACKGROUND AND OBJECTIVES: The development of a retropharyngeal hematoma following a blunt trauma is a rare occurrence. However, a spaceoccupying lesion in this area can be life-threatening and requires rapid assessment and treatment. This is clinically important because of the close proximity of the retropharyngeal space to the upper airway. Any swelling in the the posterior pharyngeal space may prompt it to bulge anteriorly into the airway and cause its obstruction. CASE REPORT: A 86-year-old woman fell from a height of 1.5 m and hit her neck on stairs and was admitted to our trauma department. A computerized tomography scan and a lateral neck x-ray to observe the soft tissue revealed a large retropharyngeal mass extending from the base of the skull down to the level of the lung. The patient was kept under observation and the hematoma reduced spontaneously in the following seven days although the patient died on the tenth day from pulmonary infection. The report emphasizes that early drainage of a retropharyngeal hematoma should be considered in similar cases. Although rarely encountered, retropharyngeal hematoma is a problem that can be faced in an emergency department.


JUSTIFICATIVA Y OBJETIVOS: El desarrollo del hematoma retrofaríngeo posterior al trauma contundente es un hecho raro. Sin embargo, una lesión que ocupa un espacio en esa área puede ser fatal, lo que exige una rápida evaluación y el tratamiento adecuado. Ese tipo de hematoma es clínicamente importante debido a la cercanía entre el espacio retrofaríngeo y la vía aérea superior. Cualquier hinchazón en ese espacio puede causar una protuberancia de la pared posterior de la faringe contra las vías aéreas y obstruirlas. RELATO DE CASO: Paciente del sexo femenino, de 86 años, que se cayó de una altura de 1,5 m y se dio con la escalera en el cuello. Fue admitida en nuestro Departamento de Traumatología. Se realizaron la tomografía computadorizada y la radiografía de los tejidos suaves del cuello, lo que arrojó una gran masa retrofaríngea que se extendía desde la base del cráneo hasta el nivel de los pulmones. La paciente permaneció en observación y el tamaño del hematoma se redujo espontáneamente en los siete días posteriores; sin embargo, y debido a una infección pulmonar, la paciente falleció al décimo día. Ese relato nos muestra que el drenaje rápido del hematoma retrofaríngeo podría haber sido considerado en ese caso. Y aunque sea de una baja incidencia, el hematoma retrofaríngeo es un problema que puede ser encontrado en los servicios de emergencia.


Subject(s)
Aged, 80 and over , Female , Humans , Hematoma/etiology , Neck Injuries/complications , Wounds, Nonpenetrating/complications , Injury Severity Score , Pharynx
14.
Rev. bras. anestesiol ; 62(5): 738-740, set.-out. 2012. ilus
Article in Portuguese | LILACS | ID: lil-649555

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Lipoma é uma doença de crescimento progressivo que pode surgir em qualquer parte do corpo. O seu aparecimento na parte de trás do pescoço, especialmente quando é grande o bastante para causar restrição do pescoço, principalmente da extensão, é um desafio para os anestesiologistas sempre que precisam manejar as vias aéreas. Aqui, o papel do Airtraq® foi avaliado no movimento restrito do pescoço. RELATO DE CASO: Relatamos o caso de uma paciente selecionada para remoção cirúrgica eletiva de um lipoma enorme na nuca, medindo 14 x 12 cm, que apresentou dificuldade para assegurar a permeabilidade das vias aéreas por meio de laringoscopia convencional. Para resolver o problema, usamos com sucesso um dispositivo recentemente desenvolvido, o Airtraq®, que é um laringoscópio óptico para assegurar a via aérea. CONCLUSÃO: O Airtraq® pode ser usado para intubação eletiva em pacientes com movimentos restritos do pescoço.


BACKGROUND AND OBJECTIVES: Lipoma is a progressively increasing disease which may appear anywhere in the body. Its appearance at the back of the neck, especially when it is large enough to cause restriction of neck extension, poses challenges to anesthesiologists in airway management whenever needed. This paper evaluates the role of Airtraq® in restricted neck movement. CASE REPORT: Case with a huge lipoma of 14 x 12 cm at the nape, and its surgical removal during an elective operation theatre posed difficulty in securing the airway by conventional laryngoscopy. To overcome the problem we successfully used a newly developed device, the Airtraq®, which is an optical laryngoscope for securing the airway. CONCLUSION: Airtraq® can be used for elective intubation in patients with restricted neck movements.


JUSTIFICATIVA Y OBJETIVOS: El Lipoma es una enfermedad de crecimiento progresivo que puede surgir en cualquier parte del cuerpo. Su aparecimiento en la parte de atrás del cuello, especialmente cuando es bastante grande para causar su restricción, principalmente en la extensión, es un reto para los anestesistas que necesitan siempre manejar las vías aéreas. Aquí el papel del Airtraq® se avaluó en el movimiento restringido del cuello. RELATO DE CASO: Caso de una paciente seleccionada para la retirada quirúrgica electiva de un lipoma enorme en la nuca, que medía 14 x 12 cm, y que tuvo una dificultad para asegurar la permeabilidad de las vías aéreas por medio de una laringoscopia convencional. Para resolver el problema, ha utilizado exitosamente un dispositivo recientemente desarrollado, el Airtraq®, que es un laringoscopio óptico para asegurar la vía aérea. CONCLUSIONES: El Airtraq® puede ser usado para la intubación electiva en pacientes con movimientos restringidos del cuello.


Subject(s)
Female , Humans , Middle Aged , Head and Neck Neoplasms/pathology , Intubation, Intratracheal/instrumentation , Laryngoscopes , Laryngoscopy , Lipoma/pathology , Equipment Design
15.
Rev. bras. anestesiol ; 62(3): 340-345, maio-jun. 2012. tab
Article in Portuguese | LILACS | ID: lil-626510

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A indução da anestesia geral em pacientes com "estômago cheio" pode resultar em regurgitação do conteúdo gástrico e aspiração pulmonar. A indução em sequência rápida (ISR) tem a função de minimizar o intervalo de tempo entre a perda dos reflexos protetores da via aérea e intubação traqueal com um tubo com balonete. O objetivo desse estudo foi avaliar a execução da indução em sequência rápida entre os anestesiologistas do Hospital São Paulo. MÉTODO: Os participantes responderam o questionário de forma voluntária e anônima, após esclarecimento e livre consentimento. O questionário continha 60 questões acerca dos pontos fundamentais da ISR. As questões se dividiam em pré-oxigenação, circuitos, drogas utilizadas na indução (opioides, hipnóticos, bloqueadores neuromusculares), técnicas de pressão cricoide, intubação e intubação difícil. RESULTADOS: Foram aplicados 75 questionários, sendo 22 descartados por preenchimento incompleto. Todos anestesiologistas declaram sempre realizar pré-oxigenação e administrar opioide, hipnótico e bloqueador neuromuscular. A maioria utiliza fentanila (83%), propofol (74,5%) e succinilcolina (68,6%). Todos anestesiologistas realizam pressão cricoide. A maioria não soube a pressão correta a ser aplicada na cartilagem cricoide. As falhas de intubação já ocorreram com 71,7% dos anestesiologistas e com 40% a regurgitação. Diante de uma intubação difícil e inesperada, 35,5% dos anestesiologistas solicitam máscara laríngea. CONCLUSÕES: Este estudo mostrou uma ampla variedade individual na técnica da ISR, fato já relatado por diversos autores. A dificuldade em se estabelecer um protocolo de ISR pode ser atribuída às constantes evidências que a ciência proporciona, fazendo da atualização parte da boa prática médica ao longo dos tempos.


BACKGROUND AND OBJECTIVES: The induction of the general anesthesia in patients on "a full stomach" can result in regurgitation of the gastric content and pulmonary aspiration. The function of the rapid sequence induction (RSI) is to minimize the time interval between the loss of the airway protection reflexes and tracheal intubation tube balloon. The objective of this study was to evaluate the rapid sequence induction among the anesthesiologists of the São Paulo Hospital. METHODS: The participants answered the questionnaire voluntarily and anonymously, after signed consent. The questionnaire consisted of 60 questions about the fundamental points of the RSI. The questions were divided in pre-oxygenation, circuits, drugs used in the induction (opioids, hypnotics, neuromuscular blockers), cricoid pressure techniques, intubation and difficult intubation. RESULTS: Seventy-five questionnaires were applied and 22 were discarded due to incomplete answering. All anesthesiologists always declare doing pre-oxygenation and administering opioid, hypnotic, and neuromuscular blocker. Most use fentanyl (83%), propofol (74.5%) and succinylcoline (68.6%). All anesthesiologists apply cricoid pressure. Most did not know the correct pressure to be applied on the cricoid cartilage. Intubation failures have already occurred with 71.7% of anesthesiologists and with 40%, the regurgitation. When faced with an unexpected difficult intubation, anesthesiologists ask for the laryngeal mask (35.5%). CONCLUSIONS: This study showed a broad individual variety of the RSI technique, a fact already reported by different authors. The difficulty in establishing a RSI protocol can be attributed to constant evidence that science provides us, where updating over the years becomes good medical practice.


JUSTIFICATIVA Y OBJETIVOS: La inducción de la anestesia general en pacientes con "estómago lleno" puede resultar en una regurgitación del contenido gástrico y en la aspiración pulmonar. La inducción en secuencia rápida (ISR), tiene la función de minimizar el intervalo de tiempo entre la pérdida de los reflejos protectores de la vía aérea y la intubación traqueal con un tubo con balón. El objetivo de este estudio, fue evaluar la ejecución de la inducción en secuencia rápida entre los anestesiólogos del Hospital São Paulo. MÉTODO: Los participantes respondieron al cuestionario de forma voluntaria y anónima, con la pertinente clarificación y con la posterior firma del Término de Consentimiento Informado. El cuestionario contenía 60 preguntas sobre los puntos fundamentales de la ISR. Las preguntas se dividían en preoxigenación, circuitos, fármacos utilizados en la inducción (opioides, hipnóticos, bloqueantes neuromusculares), técnicas de presión cricoide, intubación y desentubación difícil. RESULTADOS: Se aplicaron 75 cuestionarios y de ellos, 22 se descartaron porque fueron rellenados de forma incompleta. Todos los anestesiólogos siempre realizan una preoxigenación y siempre administran opioide, hipnótico y bloqueante neuromuscular. La mayoría utiliza fentanila (83%), propofol (74,5%) y succinilcolina (68,6%). Todos los anestesiólogos realizan presión cricoide. La mayoría no tuvo conocimiento respecto de la presión correcta que sería aplicada en el cartílago cricoide. Los fallos de intubación ya ocurrieron con un 71,7% de los anestesiólogos y con un 40% la regurgitación. Frente a una intubación difícil e inesperada los anestesiólogos solicitan mascarilla laríngea (35,5%). CONCLUSIONES: Este estudio mostró una amplia variedad individual en la técnica de la ISR, hecho que ya fue relatado por diversos autores. La dificultad en establecer un protocolo de ISR puede ser atribuida a las constantes evidencias que la ciencia nos proporciona, haciendo con que la actualización forme parte de la buena práctica médica a lo largo de los tiempos.


Subject(s)
Humans , Anesthesiology , Anesthesia, General/methods , Hospitals, University , Practice Patterns, Physicians' , Surveys and Questionnaires , Time Factors
16.
Rev. bras. anestesiol ; 62(2): 147-153, mar.-abr. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-618201

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Comparar os efeitos de dexmedetomidina e fentanil sobre as alterações hemodinâmicas em fumantes crônicos do sexo masculino. MÉTODOS: Este é um estudo prospectivo, randômico e cego. Sessenta pacientes do sexo masculino, tabagistas crônicos, com idades entre 16 e 60 anos foram selecionados. Os pacientes foram alocados aleatoriamente em dois grupos: Grupo D (n = 30) recebeu 1 µg.kg-1 de dexmedetomidina e Grupo F (n = 30) recebeu 3 µg.kg-1 de fentanil em 150 mL de solução salina normal, com início 10 minutos antes da indução da anestesia. Antes da intubação, a frequência cardíaca e a pressão arterial dos pacientes foram medidas. Após a indução da anestesia para intubação endotraqueal, a frequência cardíaca e os valores da pressão arterial foram novamente medidos 1, 3 e 5 minutos após a intubação. RESULTADOS: A frequência cardíaca estava baixa no Grupo D antes da indução da anestesia, intubação e no primeiro e terceiro minutos pósintubação. A pressão arterial sistólica estava baixa no Grupo F antes da intubação. Embora a pressão arterial diastólica estivesse menor antes da indução da anestesia e aos 5 minutos após a intubação em ambos os grupos, ela já estava baixa no Grupo F antes mesmo da intubação. Enquanto a pressão arterial média estava baixa no Grupo D antes da indução anestésica, ela estava baixa no Grupo F antes da intubação. Os valores para o duplo produto (frequência cardíaca vezes pressão arterial sistólica) estavam baixos no Grupo D antes da indução e no 1º e 3º minutos após a intubação. CONCLUSÕES: A dexmedetomidina, aplicada em fumantes crônicos do sexo masculino via infusão a uma dose de 1 µg.kg-1 10 minutos antes de indução anestésica, controla melhor as elevações da frequência cardíaca e do duplo produto a 1 e 3 minutos após a intubação, comparado ao grupo que recebeu 3 µg.kg-1 de fentanil.


BACKGROUND AND OBJECTIVES: To compare the effect of dexmedetomidine and fentanyl on hemodynamic changes in chronic male smokers. METHODS: This is a prospective, randomized, blinded study. Were selected 60 chronic male smokers (aged 16 to 60 years). The patients were randomly divided into two groups: Group D (n = 30) received 1 µg.kg-1 dexmedetomidine and Group F (n = 30) received 3 µg.kg-1 fentanyl in 150 mL of normal saline, beginning 10 minutes before anesthesia induction. Before intubation, the heart rate and blood pressure of patients were measured. After anesthesia induction for endotracheal intubation, heart rate and blood pressure values were measured at 1, 3, and 5 minutes after intubation. RESULTS: Heart rate was low in Group D before anesthesia induction, intubation, and at the 1st and 3rd minutes after intubation. Systolic arterial pressure was low in Group F before intubation. Although diastolic arterial pressure was lower before anesthesia induction and at 5 minutes after intubation in both groups, it was already low in Group F before intubation. Whereas the mean arterial pressure was low in Group D before anesthesia induction, it was low in Group F before intubation. The values for rate-pressure product were low in Group D before induction and at 1 and 3 minutes after intubation. CONCLUSIONS: Dexmedetomidine, which was applied via infusion at a loading dose of 1 µg.kg-1 10 minutes before anesthesia induction in chronic male smokers, better suppressed increases in heart rate and rate-pressure product at 1 and 3 minutes after intubation compared to the group receiving 3 µg.kg-1 fentanyl.


JUSTIFICATIVA Y OBJETIVOS: Comparar los efectos de la dexmedetomidina y del fentanil sobre las alteraciones hemodinámicas en fumadores crónicos del sexo masculino. MÉTODOS: Este es un estudio prospectivo, randómico y ciego. Sesenta pacientes del sexo masculino, fumadores crónicos, con edades entre los 16 y los 60 años, fueron seleccionados. Los pacientes fueron divididos aleatoriamente en dos grupos: Grupo D (n = 30) recibió 1 µg.kg-1 de dexmedetomidina o 3 µg.kg-1 de fentanil, y el Grupo F (n = 30) que recibió 150 mL de solución salina normal, con inicio 10 minutos antes de la inducción de la anestesia. Antes de la intubación, se mensuraron la frecuencia cardíaca y la presión arterial de los pacientes. Después de la inducción de la anestesia para la intubación endotraqueal, la frecuencia cardíaca y los valores de la presión arterial fueron medidos uno, tres y cinco minutos después de la intubación. RESULTADOS: La frecuencia cardíaca estaba baja en el Grupo D antes de la inducción de la anestesia, de la intubación y en el primero y tercer minutos posintubación. La presión arterial sistólica estaba baja en el Grupo F antes de la intubación. Aunque la presión arterial diastólica fuese menor antes de la inducción de la anestesia y a los cinco minutos después de la intubación en ambos grupos, ella ya estaba baja en el Grupo F antes incluso de la intubación. Mientras la presión arterial promedio estaba baja en el Grupo D antes de la inducción anestésica, estaba baja también en el Grupo F antes de la intubación. Los valores para el doble producto (frecuencia cardíaca por la presión arterial sistólica), eran bajos en el Grupo D antes de la inducción y en el 1º y 3º minutos después de la intubación. CONCLUSIONES: Descubrimos pues, que la dexmedetomidina, que fue aplicada en fumadores crónicos del sexo masculino vía infusión a una dosis de 1 µg.kg-1 10 minutos antes de la inducción anestésica, controla mejor las elevaciones de la frecuencia cardíaca y del doble producto a uno y tres minutos después de la intubación, comparado al grupo que recibió 3 µg.kg-1 de fentanil.


Subject(s)
Adolescent , Adult , Humans , Male , Middle Aged , Young Adult , Anesthetics, Intravenous/pharmacology , Blood Pressure/drug effects , Dexmedetomidine/pharmacology , Fentanyl/pharmacology , Heart Rate/drug effects , Hypnotics and Sedatives/pharmacology , Intubation, Intratracheal , Smoking , Prospective Studies , Single-Blind Method
17.
Rev. bras. anestesiol ; 61(5): 558-560, set.-out. 2011. tab
Article in Portuguese | LILACS | ID: lil-600948

ABSTRACT

JUSTIFICATIVA E OBJETIVO: Avaliar se manobra de hiperinsuflação manual (HM) pode propiciar aspiração das secreções orofaríngeas em paciente sob ventilação mecânica. MÉTODOS: Participaram do estudo pacientes adultos sob ventilação mecânica nos quais foi injetado corante na cavidade orofaríngea e aspirada secreção traqueal após 30 minutos (min). Na ocorrência de deslizamento do corante, o paciente foi eliminado. Os demais foram alocados em Grupo Controle: pacientes em que se aspiravam secreções traqueais após 30, 60, 120 e 180 min e Grupo Experimental: após 30 min, foram realizadas manobras de HM e aspirada secreção nos intervalos estabelecidos. RESULTADOS: Estudaram-se 43 pacientes. Em 13, ocorreu deslizamento do corante após 30 min antes da alocação dos grupos. Os demais 29 pacientes forneceram 226 amostras de secreções. Houve presença de secreções coradas em apenas duas amostras, após realização de HM, em pacientes do grupo experimental. CONCLUSÃO: A manobra de hiperinflação manual não propiciou aspiração de secreções orofaríngeas em paciente sob ventilação mecânica.


BACKGROUND AND OBJECTIVES: To evaluate whether manual hyperinflation maneuvers can cause aspiration of oropharyngeal secretions in patients under mechanical ventilation. METHODS: Adult patients under mechanical ventilation in whom a dye was injected in the oropharyngeal cavity and had their tracheal secretion aspirated after 30 minutes (min) participated in this study. In the event of dye slid, the patient was eliminated. The other patients were divided in Control Group: patients in whom tracheal secretions were aspirated after 30, 60, 120, and 180 min, and Experimental Group: after 30 min, manual hyperventilation maneuvers were performed and secretions were aspirated on the established intervals. RESULTS: Forty-three patients were enrolled in this study. In 13, dye slippage was observed after 30 min, before allocating them into two groups. In the remaining 29 patients, 226 secretion samples were collected. In only two samples the presence of dye in the secretion was observed after manual hyperinflation maneuvers in the experimental group. CONCLUSION: Manual hyperinflation maneuvers did not cause aspiration of oropharyngeal secretions in patients under mechanical ventilation.


JUSTIFICATIVA Y OBJETIVO: Evaluar si la maniobra de hiperinsuflación manual (HM), puede propiciar la aspiración de las secreciones orofaríngeas en el paciente que está bajo ventilación mecánica. MÉTODOS: Participaron en el estudio pacientes adultos bajo ventilación mecánica, en los cuales se inyectó un colorante en la cavidad orofaríngea y se aspiró la secreción traqueal después de 30 minutos (min). Al ocurrir el deslizamiento del colorante, el paciente fue eliminado. Los demás pacientes fueron derivados al Grupo Control: pacientes en que se aspiraban secreciones traqueales después de 30, 60, 120 y 180 min y un Grupo Experimental: después de 30', en que fueron realizadas las maniobras de HM y aspirada la secreción en los intervalos establecidos. RESULTADOS: Fueron estudiados 43 pacientes. En 13 de ellos, ocurrió deslizamiento del colorante después de 30 min antes de la ubicación de los grupos. Los demás 29 pacientes suministraron 226 muestras de secreciones. Se registró la presencia de secreciones de colorante en solamente dos muestras después de la realización de HM, en pacientes del grupo experimental. CONCLUSIONES: La maniobra de hiperinflación manual no generó la aspiración de secreciones orofaríngeas en el paciente bajo ventilación mecánica.


Subject(s)
Humans , Adult , Respiratory Aspiration/complications , Intubation, Intratracheal , Postoperative Care , Respiration, Artificial
18.
Rev. bras. anestesiol ; 61(4): 451-455, jul.-ago. 2011. tab
Article in Portuguese | LILACS | ID: lil-593241

ABSTRACT

PACIENTES E MÉTODOS: Ensaio clínico randomizado conduzido em 40 pacientes submetidos à revascularização do miocárdio alocados em dois grupos: estilete luminoso e laringoscópio rígido. Avaliaram-se frequência cardíaca, pressão arterial média, alterações do segmento ST e pressão venosa central durante o preparo do paciente, 1 minuto e 5 minutos após a indução anestésica e 1 minuto após a intubação traqueal, além do tempo de intubação traqueal em cada grupo. RESULTADOS: Os grupos mostraram-se homogêneos em relação aos dados demográficos. O tempo de intubação traqueal para o grupo laringoscópio rígido (24 ± 5 s) foi menor que no grupo estilete luminoso (28 ± 7 s), porém sem significância. A frequência cardíaca diminui nos dois grupos durante a indução (p < 0,05), mas 1 minuto após a intubação, a frequência cardíaca aumentou para valores próximos ao momento do preparo em ambos os grupos (p > 0,05). No grupo laringoscópio rígido, a pressão arterial média aumentou após a intubação traqueal para valores próximos ao momento do preparo do paciente (p > 0,05), enquanto no grupo estilete luminoso a pressão arterial média ficou abaixo dos valores basais (p < 0,05). A pressão venosa central aumentou em ambos os grupos em todos os momentos (p < 0,05). CONCLUSÕES: Neste estudo, é possível observar que ambas as técnicas são seguras para intubação traqueal em pacientes coronariopatas. Contudo, o estilete luminoso apresenta menor repercussão na pressão arterial média.


BACKGROUND AND OBJECTIVE: Anesthesiologists are responsible for airway management whenever they assume the anesthesia of a patient. In this study, we compare the hemodynamic parameters of rigid laryngoscopy and lighted stylet in patients with coronariopathies. PATIENTS AND METHODS: This randomized clinical trial included 40 patients undergoing myocardial revascularization assigned into two groups: lighted stylet and rigid laryngoscope. Besides time of tracheal intubation in each group, heart rate, mean arterial pressure, changes in ST segment, and central venous pressure were evaluated during patient preparation, 1 minute and 5 minutes after anesthetic induction, and 1 minute after tracheal intubation. RESULTS: Both groups were homogenous regarding demographic data. Time of tracheal intubation in the rigid laryngoscope group (24 ± 5 sec) was lower than that of the lighted stylet group (28 ± 7 sec), but without significance. Heart rate showed a reduction in both groups during anesthetic induction (p < 0.05), but 1 minute after tracheal intubation the heart rate increased to levels close to baseline levels in both groups (p > 0.05). In the rigid laryngoscope group mean arterial pressure increased after tracheal intubation to levels close to those observed during patient preparation (p > 0.05), while in the lighted stylet group mean arterial pressure remained below baseline levels (p < 0.05). Central venous pressure increased on both groups at all times (p < 0.05). CONCLUSIONS: It was possible to observe that both techniques are safe for tracheal intubation in patients with coronariopathies. However, lighted stylet has fewer repercussions on mean arterial pressure.


JUSTIFICATIVA Y OBJETIVOS: El anestesiólogo está en contacto con el manejo de la vía aérea siempre que aplica una anestesia. En este estudio, estamos evaluando los parámetros hemodinámicos entre el laringoscopio rígido y el estilete luminoso en pacientes con coronariopatías. PACIENTES Y MÉTODOS: Este ensayo clínico randomizado fue llevado a cabo con la participación de 40 pacientes sometidos a la revascularización del miocardio, y divididos en dos grupos: estilete luminoso y laringoscopio rígido. Se evaluaron la frecuencia cardíaca, la presión arterial promedio, alteraciones del segmento ST y la presión venosa central durante la preparación del paciente, 1 minuto después de la inducción anestésica, 5 minutos después de la inducción anestésica y 1 minuto después de la intubación traqueal, además del tiempo de intubación traqueal en cada grupo. RESULTADOS: Los grupos fueron homogéneos con relación a los datos demográficos. El tiempo de intubación traqueal para el grupo laringoscopio rígido (24 ± 5 seg), fue menor que en el grupo estilete luminoso (28 ± 7 seg), sin embargo con p > 0,05. La frecuencia cardíaca se reduce en los dos grupos durante la inducción (p < 0,05), sin embargo, 1 minuto después de la intubación, la frecuencia cardíaca aumentó alcanzando valores próximos al momento de la preparación en los dos grupos (p > 0,05). En el grupo laringoscopio rígido la presión arterial promedio aumentó después de la intubación traqueal para valores próximos al momento de la preparación del paciente (p > 0,05), mientras que en el grupo estilete luminoso la presión arterial promedio quedó por debajo de los valores basales con p < 0,05. La presión venosa central aumentó en ambos grupos durante todos los momentos (p < 0,05). CONCLUSIONES: En este estudio, pudimos observar que ambas técnicas son seguras para la intubación traqueal en pacientes con coronariopatías. Sin embargo, el EL presenta una menor repercusión en la presión arterial promedio.


Subject(s)
Humans , Middle Aged , Coronary Artery Disease/physiopathology , Coronary Artery Disease/surgery , Hemodynamics , Intubation, Intratracheal/instrumentation , Intubation, Intratracheal/methods , Laryngoscopes , Laryngoscopy , Myocardial Revascularization
19.
Rev. bras. anestesiol ; 61(4): 476-478, jul.-ago. 2011. ilus
Article in Portuguese | LILACS | ID: lil-593244

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: O manejo da via aérea difícil em cirurgia torácica é um assunto peculiar, devido às exigências da ventilação monopulmonar com o uso de tubos de duplo-lúmen. O auxílio da broncoscopia flexível é de enorme importância, porém nem sempre está disponível. O objetivo deste relato é descrever um caso de intubação orotraqueal seletiva retrógrada na ausência de equipamento de endoscopia específico para o procedimento. RELATO DO CASO: Paciente com história prévia de retossigmoidectomia internou-se para abordagem cirúrgica de lesão pulmonar por toracotomia direita. Avaliação anestésica pré-operatória não revelava particularidades nem na história clínica nem no exame físico. Após indução anestésica e ventilação com máscara facial, à laringoscopia direta duas tentativas de intubação orotraqueal mostraram-se inefetivas devido à difícil visualização das pregas vocais (Cormack-Lehane grau III). Em função da indisponibilidade de material específico para intubação seletiva endoscópica optou-se pela técnica retrógrada utilizando tubo de duplo-lúmen. O paciente foi extubado na sala cirúrgica logo após o término da cirurgia e não apresentou complicações decorrentes da técnica alternativa. CONCLUSÕES: A intubação orotraqueal seletiva retrógrada mostrou-se uma técnica alternativa minimamente invasiva, de baixo custo, segura e, ainda, extremamente útil quando não se conta com o auxílio da broncoscopia flexível.


BACKGROUND AND OBJECTIVE: Difficult airway management in thoracic surgeries is a peculiar subject due to the demands of monopulmonary ventilation with double-lumen tubes. Flexible bronchoscopy guidance is extremely important, but it is not always available. The objective of this report was to describe a case of retrograde selective orotracheal intubation in the absence of specific endoscopy equipment for the procedure. CASE REPORT: This is a patient with a history of retosigmoidectomy, admitted for a right thoracotomy for a lung lesion. Preoperative anesthetic evaluation did not reveal any clinical and physical exam particularities. After anesthetic induction and ventilation with face mask, two attempts of orotracheal intubation under direct laryngoscopy were ineffective due to difficult visualization of the vocal folds (Cormack-Lehane grade III). Due to the unavailability of specific material for selective endoscopic intubation it was decided to use the retrograde technique using the double-lumen tube. The patient was extubated in the operating room shortly after the end of the surgery without complications secondary to the alternative technique. CONCLUSIONS: Retrograde selective orotracheal intubation is a minimally invasive technique, low cost, safe, and extremely useful whenever flexible bronchoscopy is not available.


JUSTIFICATIVA Y OBJETIVOS: El manejo de la vía aérea difícil en cirugía torácica es un asunto peculiar, debido a las exigencias de la ventilación monopulmonar con el uso de tubos de doble lumen. El auxilio de la broncoscopia flexible es de enorme importancia, sin embargo no siempre está disponible. El objetivo de este relato, es describir un caso de intubación orotraqueal selectiva retrógrada en la ausencia de un equipo de endoscopia específico para el procedimiento. RELATO DEL CASO: Paciente con historial previo de retosigmoidectomía que fue ingresado para el abordaje quirúrgico de la lesión pulmonar por toracotomía derecha. La evaluación anestésica preoperatoria no revelaba particularidades ni en la historia clínica ni en el examen físico. Después de la inducción anestésica y ventilación con máscara facial, en la laringoscopia derecha dos intentos de intubación orotraqueal no tuvieron el efecto esperado debido a una difícil visualización de las cuerdas vocales (Cormack-Lehane grado III). En función de la indisponibilidad de un material específico para la intubación selectiva endoscópica, se optó por la técnica retrógrada utilizando un tubo de doble lumen. El paciente fue desentubado en quirófano enseguida que terminó la operación y no presentó complicaciones provenientes de la técnica alternativa. CONCLUSIONES: La intubación orotraqueal selectiva retrógrada fue una técnica alternativa mínimamente invasiva de bajo coste, segura e incluso extremadamente útil cuando no se cuenta con la ayuda de la broncoscopia flexible.


Subject(s)
Humans , Male , Middle Aged , Intubation, Intratracheal/instrumentation , Intubation, Intratracheal/methods
20.
Rev. bras. anestesiol ; 61(3): 371-375, maio-jun. 2011. tab
Article in Portuguese | LILACS | ID: lil-588164

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A artrite reumatoide (AR) é uma doença inflamatória crônica e de etiologia desconhecida. Os pacientes com AR são reconhecidos como pessoas com redução na expectativa de vida, em comparação com a população em geral. As doenças reumáticas são numerosas e ocorrem com alta variabilidade; algumas são desenvolvidas rapidamente; outras, cronicamente, provocando incapacidades durante toda a vida. Os riscos anestésicos, em desordens osteoarticulares, envolvem, além das deformidades mecânicas causadas pela doença, os sistemas cardiovascular, respiratório, renal e digestivo. CONTEÚDO: A proposta da presente revisão foi levantar a importância das fases da doença em processo, que podem influenciar no controle da anestesia antes, durante e após a cirurgia, destacando a experiência dos autores em uma avaliação retrospectiva dos casos de pacientes portadores de artrite reumatoide juvenil (ARJ) submetidos a próteses ortopédicas, com ênfase para as técnicas de intubação. CONCLUSÕES: Pacientes com artrite reumatoide podem apresentar um bom número de problemas complexos para o anestesiologista. Isso requer uma cuidadosa avaliação pré-operatória; a anestesia requer experiência com a técnica e o cuidado pós-operatório deve ser criteriosamente escolhido para atender à necessidade específica do paciente. O procedimento demanda efetiva comunicação entre cirurgião, reumatologista e anestesiologista, para que cada membro do grupo multidisciplinar contribua com sua experiência, visando a um melhor benefício ao paciente.


BACKGROUND AND OBJECTIVES: Rheumatoid arthritis (RA) is a chronic inflammatory disease of unknown etiology. It is known that RA patients have a reduced life expectancy when compared with the general population. Rheumatic diseases are numerous and occur with high variability; some of them develop very rapidly while others occur chronically provoking disability throughout life. Anesthetic risks in osteoarticular disorders involve not only the mechanical deformations caused by the disease, but also the cardiovascular, respiratory, renal, and digestive systems. CONTENTS: The purpose of this review was to stress the importance of stages in disease process that may affect anesthesia control before, during, and after surgery, highlighting the authors' experience in a retrospective review of patients with juvenile rheumatoid arthritis (JRA) undergoing placement of orthopedic prosthesis with emphasis on intubation techniques. CONCLUSIONS: Rheumatoid arthritis patients can present a number of complex problems for the anesthesiologist. This requires careful preoperative evaluation; anesthesia requires experience with the technique; and postoperative care should be judiciously chosen to meet the specific needs of the patient. The procedure requires effective communication among surgeon, rheumatologist and anesthesiologist so each member of the multidisciplinary team can contribute with his/her expertise in order to better benefit the patient.


JUSTIFICATIVA Y OBJETIVOS: La artritis reumatoide (AR), es una enfermedad inflamatoria crónica y de etiología desconocida. Los pacientes con AR son reconocidos como personas que tienen una reducción en la expectativa de vida, en comparación con la población en general. Las enfermedades reumáticas son numerosas y ocurren con una alta variabilidad; algunas son desarrolladas rápidamente; otras, crónicamente, provocando incapacidades durante toda la vida. Los riesgos anestésicos, en los desórdenes osteoarticulares, involucran además de las deformidades mecánicas causadas por la enfermedad, los sistemas cardiovascular, respiratorio, renal y digestivo. CONTENIDO: La propuesta de la presente revisión fue destacar la importancia de las fases de la enfermedad en proceso, que pueden influir en el control de la anestesia antes, durante y después de la cirugía, destacando la experiencia de los autores en una evaluación retrospectiva de los casos de pacientes portadores de artritis reumatoide juvenil (ARJ), sometidos a prótesis ortopédicas, con énfasis en las técnicas de intubación. CONCLUSIONES: Los pacientes con artritis reumatoide pueden presentar un buen número de problemas complejos para el anestesiólogo. Eso requiere una cuidadosa evaluación preoperatoria; la anestesia necesita tener ya una experiencia con la técnica y el cuidado postoperatorio debe ser juiciosamente elegido para atender a la necesidad específica del paciente. El procedimiento exige una efectiva comunicación entre el cirujano, el reumatólogo y el anestesiólogo, para que cada miembro del grupo multidisciplinario contribuya con su experiencia, y así lograr un mejor beneficio para el paciente.


Subject(s)
Humans , Anesthesia , Arthritis, Rheumatoid , Arthritis, Rheumatoid/complications , Risk Factors