Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Arq. bras. med. vet. zootec. (Online) ; 72(2): 641-646, Mar./Apr. 2020. tab, graf
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1128497

ABSTRACT

Cheese whey is a nutritious byproduct in the dairy industry, however, due to low commercial value, its use as a milk adulterant is a common practice not easily detected by routine analysis. In Brazil, quantification of caseinomacropeptide (CMP) index, using High Performance Liquid Chromatography (HPLC), is officially used to investigate illegal cheese whey addition to milk. Milk with CMP index above 30mg/L is considered not suitable for human consumption. The objective of this research was to report the CMP index in 185 samples of pasteurized milk, representing 73 commercial brands produced in 51 counties and ten mesoregions of the state of Minas Gerais, from 2011 to 2013 (58 samples) and 2015 to 2017 (127 samples). CMP index was considered normal (up to 30mg/L) in 75.1% of the samples. However, 21.1% presented CMP index above 75mg/L and 3.8% from 31 to 75mg/L. CMP index above 75mg/L was found in 17.4% of the samples produced during the dry season (April to September) and in 24.7% during the rainy season (October to March). These data point to the need of more efficient monitoring and inspection processes to hinder adulteration with cheese whey addition to milk.(AU)


Subject(s)
Peptides , Caseins/analysis , Milk , Pasteurization , Fraud , Brazil , Food Contamination/analysis
2.
Arq. bras. med. vet. zootec. (Online) ; 71(6): 2111-2116, Nov.-Dec. 2019. tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1055147

ABSTRACT

Milk and dairy products are potential sources for spoilage and pathogenic microorganisms, and although a huge amount of data is collected by the official inspection services, only a few reports are available to the public. This study aimed to evaluate the data for physicochemical and microbiological quality of pasteurized milk and dairy products, collected for inspection at industrial establishments registered at the Instituto Mineiro de Agropecuária (IMA), which is an official inspection service in Minas Gerasi State, Brazil. A total of 192 analyzes were done in 2011, 1008 in 2012, 1368 in 2013, 1271 in 2014, 1582 in 2015, adding up to 5421 samples analyzed by standard analytical techniques in official government laboratories. The statistical analysis was descriptive. A total of 2010 analytical results were nonconform to the legal requirements. Among the results, 78 (4.3%) samples of mozzarella cheese were positive for alkaline phosphatase, and freezing point results for pasteurized milk were outside the legal requirements in 86 (10%) samples. Staphylococcus coagulase positive was above limits in 80 (4.4%) samples of mozzarella cheese. These results indicate a risk to the consumer's health even in pasteurized products, and the need for effective enforcement of good manufacturing practices in the food industries.(AU)


Subject(s)
Food Quality , Milk/microbiology , Chemical Phenomena , Microbiological Techniques
3.
Vigil. sanit. debate ; 6(3): 37-45, ago. 2018.
Article in Portuguese | LILACS | ID: biblio-913553

ABSTRACT

Introdução: O leite é um alimento de grande importância na alimentação, pois possui elevado valor nutritivo e fornece macro e micronutrientes indispensáveis ao crescimento,desenvolvimento e manutenção da saúde. Contudo, a presença de alto teor de água, proteínas, gorduras, carboidratos, minerais e vitaminas o torna vulnerável a alterações físicoquímicas e microbiológicas. O monitoramento da qualidade do leite no comércio cabe ao Sistema Nacional de Vigilância Sanitária. A execução dessa ação é responsabilidade dos órgãos de Vigilância Sanitária estaduais, distrital e municipais em articulação com os Laboratórios Centrais de Saúde Pública (Lacen). Objetivo: Avaliar parâmetros microbiológicos e físicoquímicos dos leites pasteurizados e UHT comercializados no Distrito Federal (DF), por meio de laudos emitidos pelo Lacen-DF. Método: Foram analisadas 276 amostras, 228 de leites UHT e 48 de leites pasteurizados, coletadas entre 2015 e 2017. Resultados: Estavam insatisfatórias 0,4% das amostras de leite UHT, por apresentarem teor de proteína abaixo do valor de referência, e 37,5% das amostras de leite pasteurizado não atenderam aos padrões físico-químicos e microbiológicos, apresentando problemas na prova de cocção (2,1%), acidez (12,5%), teor de gordura (6,3%), SNG (12,5%), índice crioscópico (14,6%), coliformes (13,5%), rotulagem (13,5%) e avaliação sensorial (6,3%). Conclusões: Há necessidade de ação fiscalizadora permanente da Vigilância Sanitária em parceria com outros órgãos, no sentido de realizar medidas de controle de qualidade, visando garantir um alimento seguro ao consumidor.


Introduction: Milk is a food of great importance in human nutrition. Its high nutritional value provides macro and micronutrients indispensable for growth, development and maintenance of health. However, the presence of high water contents, proteins, fats, carbohydrates, minerals and vitamins makes it vulnerable to physico-chemical and microbiological changes. Monitoring of the quality of milk in trade is the responsibility of the National Health Surveillance System. The execution of this action is the responsibility of the state, district and municipal Sanitary Vigilance organs in liaison with the Central Public Health Laboratories (Lacen). Objective: To evaluate the microbiological and physico-chemical parameters of the pasteurized and UHT milks sold in the Federal District (DF), through reports issued by Lacen-DF. Methods: We analyzed 276 samples, 228 of UHT milks and 48 of pasteurized milks, collected between 2015 and 2017. Results: 0,4% of the UHT milk samples presented a protein content below the reference value and 37.5% of the pasteurized milk samples did not reach physico-chemical and microbiological standards, presenting problems in the heating test (2.1%), acidity (12.5%), fat content (6.3%), nonfat milk solids (12.5%), cryoscopic index (14.6%), coliform (13.5%), labeling (13.5%) and sensory evaluation (6.3%). Conclusions: There is a need for permanent inspection by the Sanitary Surveillance in partnership with other agencies, to promote and carry out quality control measures, ensuring a safe food product for the consumer.

4.
Rev. bras. ciênc. vet ; 24(1): 52-56, jan.-mar.2017. il.
Article in English | LILACS | ID: biblio-966970

ABSTRACT

O leite beneficiado compõe uma parte importante dos alimentos mais consumidos e comercializados no mundo; no entanto, é reconhecido como um dos alimentos mais frequentemente fraudados, necessitando de monitoramento contínuo de qualidade. Objetivou-se no trabalho estudar a qualidade do leite beneficiado no Brasil, monitorado pelo Programa Oficial do Centro Integrado de Monitoramento da Qualidade de Alimentos (CQUALI-Leite), como subsídio para melhoria e aperfeiçoamento deste programa, direcionando ações corretivas para melhoria de produtos com foco em regiões de maior problemática. Para isso, foram avaliados os resultados de análises fiscais oficiais, totalizando 1556 amostras de leite beneficiado de diversas marcas comerciais disponibilizadas no comércio nacional. Os resultados obtidos evidenciaram que o leite pasteurizado foi a categoria com maior índice de irregularidades e o leite em pó a categoria de melhor qualidade, apesar de evidenciar a presença de Bacillus cereus, o que não pode ser negligenciado no controle sanitário. Concluiu-se que toda cadeia de processamento do leite beneficiado no Brasil ainda necessita de aprimoramento e monitoramento contínuos e que para aperfeiçoamento do CQUALI-Leite infere-se que o direcionamento de ações corretivas para melhoria de produtos deverá ter foco nas regiões Norte e Nordeste, principalmente quanto ao leite pasteurizado.


The processed milk makes up an important part of the food consumed and marketed in the world; however, it is acknowledged as one of the most frequently susceptible food to fraud practices, in need of continuous monitoring of quality and safety. This study aimed to assess the quality of milk processed in Brazil, monitored by the Official Program of the Integrated Center for Food Quality Monitoring (CQUALI-Milk), as a subsidy for improvement and enhancement of this program, focusing corrective actions to improve products with attention on problematic regions. For this, we evaluated the results of official analysis, totalizing 1556 samples of milk from several commercial brands available in the Brazilian retail market. The results show that pasteurized milk was the category with the highest rate of irregularities and the milk powder the category exhibiting the best quality, despite the evidence of Bacillus cereus, which cannot be overlooked in the sanitary control. Milk processing chain in Brazil still needs improvement and a continuous quality monitoring, and to enhance the CQUALI-milk we shall infer that the targeting of corrective actions to improve products should be focused in the North and Northeast regions, especially regarding the pasteurized milks.


Subject(s)
Humans , Breast-Milk Substitutes , Total Quality Management
5.
Ciênc. rural ; 46(2): 286-292, fev. 2016. tab, graf
Article in English | LILACS | ID: lil-767660

ABSTRACT

ABSTRACT: The present study focused on isolation Bacillus cereus during the UHT milk production and shelf life, to assess the enterotoxigenic production capacity of isolates and to evaluate the use of the RAPD-PCR technique to verify whether Bacillus cereus isolated at different phases of UHT milk processing belongs to the same strain. For this, six groups of milk samples composed of raw, pasteurized and UHT milk were collected from a processing plant. The results revealed that bacteria belonging to the Bacillus cereus group were isolated from 51.6%, 81.6% and from 13.8% of raw, pasteurized and UHT milk samples, respectively. About 50.0% of isolates from raw milk, 19.2% isolates from pasteurized milk and 70.7% isolates from UHT milk were capable of producing enterotoxins. It was confirmed the genetic similarity among Bacillus cereus isolates from raw, pasteurized and UHT milk, therefore demonstrating that the microorganism is able to withstand UHT treatment. These results should serve as a warning to health authorities, given that 13.8% of samples were not in accordance with standards established by the Department of Health for containing a potentially pathogen agent, therefore indicating that contamination of milk by sporulating bacteria should be avoided.


RESUMO: Objetivou-se realizar o isolamento de bactérias do grupo do Bacillus cereus e verificação da semelhança genética entre elas, através da PCR-RAPD, durante a produção e vida de prateleira do leite UAT, bem como verificar sua capacidade enterotoxigência. Para isso, foram colhidas em uma usina de beneficiamento seis grupos de amostras de leite compostos cada um por amostras de leite cru, pasteurizado e UAT. Os resultados obtidos evidenciaram que bactérias do grupo do Bacillus cereus foram isoladas de 51,6% das amostras de leite cru, de 81,6% das de leite pasteurizado e de 13,8% das de leite UAT. Demonstraram-se capazes de produzir enterotoxinas 50,0% dos isolados de leite cru, 19,2% de leite pasteurizado e 70,7% de leite UAT. Também se pode constatar a semelhança genética entre as cepas de Bacillus cereus isoladas do leite cru, pasteurizado e UAT, evidenciando assim que o micro-organismo é capaz de resistir ao tratamento por UAT. Tais resultados devem servir de alerta às autoridades sanitárias, tendo em vista que 13,8% deles estavam em desacordo com o estabelecido pelo Ministério da Saúde, por serem capazes de veicular um agente potencialmente patogênico, demonstrando assim que a contaminação do leite por bactérias esporuladas deve ser motivo de preocupação.

6.
Rev. Inst. Adolfo Lutz (Online) ; 73(3): 298-301, jul.-set. 2014. graf
Article in Portuguese | LILACS, SES-SP | ID: lil-783205

ABSTRACT

Os métodos microbiológicos alternativos apresentam vantagens sobre os ensaios convencionais, no entanto é preciso confirmar sua eficácia. O presente trabalho avaliou o sistema Petrifilm™ HS com o sistema Petrifilm™ EC, em comparação com a metodologia convencional na contagem de coliformes a 35 ºC em leite pasteurizado. Altas correlações foram encontradas entre as metodologias utilizadas para efetuar a contagem de coliformes a 35 ºC. O sistema Petrifilm™ HS para contagem de coliformes a 35 ºCem leite pasteurizado mostrou resultados satisfatórios...


Subject(s)
Humans , Colimetry/methods , Milk , Food Microbiology/methods
7.
Braz. j. pharm. sci ; 50(2): 337-343, Apr-Jun/2014. graf
Article in English | LILACS | ID: lil-722194

ABSTRACT

Food contamination caused by enteric pathogens is a major cause of diarrheal disease worldwide, resulting in high morbidity and mortality and significant economic losses. Bacteria are important agents of foodborne diseases, particularly diarrheagenic Escherichia coli. The present study assessed the genetic diversity and antimicrobial resistance of E. coli isolates from pasteurized milk processed in 21 dairies in northwestern State of Parana, Brazil. The 95 E. coli isolates were subjected to antimicrobial susceptibility testing according to the recommendations of the Clinical and Laboratory Standards Institute and assessed genotypically by Enterobacterial Repetitive Intergenic Consensus-Polymerase Chain Reaction (ERIC-PCR). The highest rate of resistance was observed for cephalothin (55.78%). ERIC-PCR revealed high genetic diversity, clustering the 95 bacterial isolates into 90 different genotypic patterns. These results showed a heterogeneous population of E. coli in milk samples produced in the northwestern region of Paraná and the need for good manufacturing practices throughout the processing of pasteurized milk to reduce the risk of foodborne illnesses.


A contaminação de alimentos por patógenos entéricos é uma das principais causas de doenças diarréicas em todo o mundo, resultando em altas taxas de morbidade e mortalidade e perdas econômicas significativas. As bactérias são importantes agentes de doenças de origem alimentar, particularmente Escherichia coli diarreiogênicas. O presente estudo teve como objetivo avaliar a diversidade genética e a resistência a antimicrobianos de E. coli isoladas de leite pasteurizado, processados em 21 laticínios na região noroeste do Paraná - Brasil. Os 95 isolados de E. coli foram submetidos a testes de suscetibilidade aos antimicrobianos de acordo com as recomendações do Clinical and Laboratory Standards Institute e avaliados genotipicamente por ERIC-PCR (Enterobacterial Repetitive Intergenic Consensus - Polymerase Chain Reaction). O principal perfil de resistência encontrado entre os isolados foi resistência à cefalotina (55,78%). ERIC-PCR revelou alta diversidade genética, agrupando os 95 isolados bacterianos em 90 diferentes perfis genotípicos. Estes resultados mostraram uma população heterogênea de E. coli em amostras de leite produzido na região noroeste do Paraná e a necessidade de boas práticas na manipulação de todo o processamento de leite pasteurizado, a fim de reduzir o risco de doenças transmitidas por alimentos.


Subject(s)
Genetic Heterogeneity , Milk/classification , Escherichia coli/classification , Pasteurization/instrumentation , /analysis , /prevention & control , Bacterial Typing Techniques
8.
Hig. aliment ; 27(226/227): 116-121, 30/12/2013. tab
Article in Portuguese | LILACS | ID: biblio-964179

ABSTRACT

Foram avaliadas as características microbiológicas do leite pasteurizado tipo C, comercializado em diferentes supermercados do município de Teixeira de Freitas-BA, comparando-as com os padrões estabelecidos pela legislação em vigor, verificando a presença de coliformes totais e termotolerantes e presença de Escherichia coli através de testes bioquímicos. Foram analisadas 24 amostras de quatro diferentes marcas comerciais. Das 24 (100%) amostras, 19 (79,16%) apresentaram coliformes totais e destas, 15 (62,50%) amostras apresentaram contaminação por coliformes termotolerantes, sendo consideradas impróprias para o consumo. Através dos testes bioquímicos foi possível identificar gêneros e espécies bacterianas da família Enterobacteriaceae.


The microbiological characteristics of milk type C had been evaluated, commercialized in different supermarkets of the Teixeira de Freitas-BA city, comparing them with the standards established for the legislation in vigor, verifying the presence of total and thermotolerants coliforms and presence of Escherichia coli through tests biochemists. 24 samples of four different commercial marks had been analyzed. Of the 24 (100%) samples, 19 (79.16%) had presented total coliforms and of these 15 (62.50%) samples had presented contamination for thermotolerants coliforms, being considered improper for the consumption. Through the tests biochemists it was possible to identify bacterial species of the Enterobacteriaceae family.


Subject(s)
Food Contamination , Colimetry/analysis , Milk , Enterobacteriaceae , Products Commerce , Food Samples , Food Production , Food Quality , Dairy Products , Food Microbiology
10.
Rev. bras. ciênc. vet ; 13(1)jan.-abr. 2006.
Article in Portuguese | LILACS-Express | LILACS, VETINDEX | ID: biblio-1491315

ABSTRACT

Um total de 300 amostras de leite foram submetidas à pesquisa de bactérias do grupo do Bacillus cereus e as cepas isoladasforam analisadas quanto à produção de enterotoxinas através do kit BCET-RPLA. Bactérias do grupo do Bacillus cereus foramverificadas em 36 amostras de leite cru, 55 de pasteurizado e 27 de UAT. Destas, 12 cepas isoladas do leite cru, 24 dopasteurizado e 24 do UAT foram submetidas ao teste de detecção de enterotoxinas. Verificou-se que 50,0% das cepasisoladas de amostras de leite cru, 20,8% das isoladas de pasteurizado e 75,0% das isoladas de UAT submetidas ao testedemonstraram-se positivas para produção de enterotoxinas. Os resultados evidenciaram maior número de cepas de Bacilluscereus enterotoxigênicos em leite UAT, o que serve de alerta para a indústria e autoridades sanitárias pela possibilidade deamostras de leite consideradas isentas de microrganismos estarem veiculando microrganismo potencialmente patogênico.

11.
Rev. bras. ciênc. vet ; 12(1-3): 1-3, 2005.
Article in Portuguese | LILACS-Express | LILACS, VETINDEX | ID: biblio-1491304

ABSTRACT

Foram analisadas 45 amostras de leite pasteurizado tipo C processado pelos laticínios do estado do Rio de Janeiro, noperíodo de janeiro a dezembro de 2001. As amostras chegaram ao laboratório diretamente dos lacticínios do interior do estadodo Rio de Janeiro, colhidas pelo Serviço de Inspeção Federal do Ministério da Agricultura. As análises de coliformes totais efecais, Contagem de Bactérias Heterotróficas Aeróbias Mesófilas (CBHAM) e pesquisa de Salmonella foram realizadas noLaboratório Analítico de Alimentos e Bebidas pertencente ao convênio MAPA/UFRRJ. Os resultados foram comparados com ospadrões microbiológicos do regulamento técnico de identidade e qualidade de leite pasteurizado do Ministério da Agricultura(BRASIL, 1999). Estavam fora do padrão, 4,4% das amostras analisadas para a contagem de BHAM, 24,4% para enumeraçãode coliformes totais e 11,1% para coliformes fecais. Não foi encontrada Salmonella em nenhuma das amostras analisadas.Os resultados encontrados indicam uma provável falha no tratamento térmico ou contaminação do produto antes ou duranteo envase, sendo necessária uma avaliação do processamento para determinar o foco do problema e evitar que a populaçãoconsuma leite de má qualidade.

12.
Rev. Inst. Adolfo Lutz ; 60(2): e35927, 2001. tab
Article in Portuguese | LILACS, ColecionaSUS, SES-SP, CONASS, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: lil-339401

ABSTRACT

Foram analisadas, de 1995 a 1998, 390 amostras de leite (123 tipo C, 86 tipo B, e 181 tipo Integral) provenientes de dezesseis mini e micro-usinas da regiäo de Ribeiräo Preto/SP. Dentre essas usinas, dez foram submetidas a um estudo longitudinal, ou seja, as amostras de leite foram analisadas durante 4 anos, sendo que cada ano correspdeu a um período. Os estabelecimentos foram fiscalizados por um médico veterinário do Serviço de Inspeçäo de Säo Paulo que, mediante os resultados das análises de leite, orientava os responsáveis pelas usinas. Dentre o total de amostras estudadas, observou-se que estavam em desacordo com os padröes físico-químicos e microbiológicos, estabelecidos pela legislaçäo em vigor, 15,5 por cento e 32,5 por cento do tipo C; 37,2 por cento e 32,6 por cento do leite tipo B e 30,9 por cento e 31,0 por cento do tipo Integral, respectivamente. Na avaliaçäo das dez mini e micro-usinas estudadas durante os 4 anos observou-se, quanto a qualidade microbiológica, que o leite tipo B apresentou uma melhora a partir do terceiro período de estudo; o de tipo Integral também no terceiro período e depois manteve níveis um pouco mais altos no decorrer do estudo. Os dados mostraram que a fiscalizaçäo e orientaçäo resultaram em uma maior adequaçäo nas condiçöes higiênico-sanitárias do leite. O mesmo näo foi observado em relaçäo às características físico-químicas. (AU)


The objective of this research was to investigate the physicochemical and microbiological quality of pasteurized milk processed by mini and microprocessing plants of the area of Ribeirão Preto, State of São Paulo, Brazil. The total of 390 samples of pasteurized milk types C,B and whole were analyzed for their physicochemical and microbiological conditions. Ten of this mini and microprocessing plants were submmited a longitudinal study, and their milk samples were analized during four years. These factories were supervised by a veterinary of the Agricultural Secretary of São Paulo State who guided each responsible for factory about the results of the milk analises. The microbiological analysis showed that 32.5% of 123 samples of type C milk, 32.6% of 86 samples of type B milk and 31.0% of 181 samples of whole milk did not comply with the legal standards established by the Brasilian legislation. By the physicochemical analysis 15.5%, 37.2% e 30.9%, respectively, did not comply with legal standards in Brazil. Salmonella were negative in all samples. The evaluation of ten mini and microprocessing plants showed that the microbiological quality of the type B milk has a improved in the last two years, the type C milk showed an improvement only in the second year of the study and the type whole milk showed a significant improvement in the third period of study. The results of this study showed that the inspection and guidance resulted in improvement of the sanitary-hygienic quality of these products. (AU)


Subject(s)
Food Quality , Consumer Product Safety , Milk , Food Handling
13.
Rev. Inst. Adolfo Lutz ; 60(2): e35922, 2001. tab, graf
Article in Portuguese | LILACS, ColecionaSUS, SES-SP, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: lil-339404

ABSTRACT

O objetivo deste estudo foi determinar o teor do princípio ativo e avaliar a inocuidade dérmica e ocular em amostras de produtos contendo 1 por cento de lindano (m/m), que säo utilizados para o tratamento de ectoparasitoses: pediculoses e escabioses. Foram analisadas 06 (seis) amostras de produtos: um xampu, um creme, dois sabonetes e duas loçöes, de diferentes marcas. O teor de lindano das amostras foi realizado de acordo com a Farmacopéia Americana, 1995. Os testes de irritaçäo dérmica e ocular foram realizados de acordo com o método de Draize modificado nas amostra e nas soluçöes alcoólicas de lindano em diferentes concentraçöes. Foi efetuado também o teste nas amostras conforme o modo de uso, isto é, de acordo com as instruçöes fornecidas pelos fabricantes dos produtos analisados. Os resultados obtidos referentes ao teror de lindano mostraram que as amostras analisadas estavam de acordo com o ter especificado no rótulo. Os resutados dos exames toxicológicos das amostras demonstraram que os produtos aplicados de acordo com o modo de uso näo evidenciaram danos à pele dos animais testados. Porém, quando submetidos ao teste de irritaçäo dérmica cumulativa, isto é, através de repetidas aplicaçöes do produto, apresentaram irritaçäo, mostrando que o produto utilizado de forma näo correta poderá acarretar lesäo à pele e consequentemente comprometer a saúde do consumidor devido à toxicidade do lindano. (AU)


The aim of this study was the quantification of the drug as well as dermal and ocularsafety evaluation in samples containing 1% lindane (w/w), that are used in the treatment of ectoparasitosis:pediculosis and scabies. Six samples were analyzed: a shampoo, a cream, two bars of toilet soap andtwo lotions of different brands. The quantification method was described in the United StatesPharmacopeia, 1995. Tests of dermal and ocular irritation using the method of Draize with modificationwere done in samples and lindane alcoholic solutions in different concentrations. In samples, also thetest was done according to the manufacturer's directions for use and composition. The results of thelindane antification showed that the analyzed samples were in accordance with the label. The resultsof the toxicological tests showed that, when applied according to manufacturer's directions, the productsusing did not damage the skin or the eyes of the animal. However, when the samples were submitted tothe cumulative dermal test, implying repeated application of the product, they showed dermal irritation.So the incorrect use was proved to cause skin damage and compromise the customers's health due to thelindane toxicity. (AU)


Subject(s)
Toxicology , Hexachlorocyclohexane , Ectoparasitic Infestations
SELECTION OF CITATIONS
SEARCH DETAIL