Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Year range
1.
Odontoestomatol ; 22(35): 38-49, jul. 2020.
Article in Spanish | LILACS, BNUY-Odon, BNUY | ID: biblio-1103059

ABSTRACT

Objetivos. Evaluar y comparar la relación entre la resistencia de unión inmediata a esmalte y microfiltración de dos sistemas restauradores a base de resina compuesta. Métodos. 40 terceros molares se dividieron aleatoriamente en dos grupos: 20 molares restaurados utilizando el sistema Adper Single bond 2 + Filtek Z250 XT (3M ESPE; ST PAUL, MN, USA); y 20 molares restaurados con el sistema Tetric N Bond + Tetric N Ceram (Ivoclar Vivadent; Schaan, Liechtenstein). La mitad de los dientes de cada grupo se utilizaron para un ensayo de microtracción, mientras que la otra mitad fueron utilizados para un ensayo de microfiltración (n = 10). Resultados. Las medias y el desvío padrón de la resistencia de unión a microtracción fueron de 27.93 (±9.55) para Adper Single bond 2 + Filtek Z250 XT MPa y 33.12 (±8.18) MPa para Tetric N Bond + Tetric N Ceram (p = 0,049). En cuanto a los valores de microfiltración, no hubo diferencias estadísticamente significativas entre los grupos (p = 0,478). No fue observada una correlación significativa entre la resistencia de unión a la microtracción y la microfiltración (R2 = 0.0909; p = 0.196). Conclusiones. No se encontró una relación entre los valores de resistencia de unión y el grado de microfiltración.


Objectives. To evaluate and compare the relationship between enamel bond strength and microleakage of two composite based restorative systems. Methods. 40 third molars were randomly divided into two groups: 20 molars restored with the Adper Single bond 2 + Filtek Z250 XT (3M ESPE; ST PAUL, MN, USA) system and 20 with the Tetric N Bond + Tetric N Ceram (Ivoclar Vivadent; Schaan, Liechtenstein) system. "Half of the teeth" in each group were subjected to a bond strength test, while the others were subjected to the microleakage test. Results. The means and standard deviation of the bond strength resistance were 27.93 (± 9.55) MPa for Adper Single bond 2 + Filtek Z250 XT system and 33.12 (± 8.18) MPa for Tetric N Bond + Tetric N Ceram system (p = 0.049). Regarding microleakage values, there were no statistically significant differences between the groups (p = 0.478). No significant correlation was observed between microtensile bond strength and microleakage (R2 = 0.0909, p = 0.196). Conclusions. No relationship was found between adhesive bond values and degree of microleakage.


Objetivos. Avaliar e comparar a relação entre a resistência de união imediata ao esmalte e a microfiltração de dois sistemas restauradores baseados em resina composta. Métodos. 40 terceiros molares foram divididos aleatoriamente em dois grupos: 20 molares restaurados usando o sistema Adper Single bond 2 + Filtek Z250 XT (3M ESPE; ST PAUL, MN, EUA); e 20 molares restaurados com o sistema Tetric N Bond + Tetric N Ceram (Ivoclar Vivadent; Schaan, Liechtenstein). Metade dos dentes de cada grupo foi utilizada para um teste de resistência de união à microtração, enquanto a outra metade foi utilizada para um teste de microfiltração (n = 10). Resultados. As mídias e o padrão de resistência de união à microtração foram 27,93 (± 9,55) para Adper Single bond 2 + Filtek Z250 XT MPa e 33,12 (± 8,18) MPa para Tetric N Bond + Tetric N Ceram (p = 0,049). Em relação aos valores de microfiltração, não houve diferença estatisticamente significativas entre os grupos (p = 0,478). Não houve correlação significativa observada entre a resistência de união à microtração e a microfiltração (R2 = 0,0909; p = 0,196). Conclusões. Não foi encontrada relação entre os valores de resistência de união e o grau de microfiltração.


Subject(s)
Composite Resins , Dental Enamel , Dental Leakage , Microstraining
2.
Eng. sanit. ambient ; 25(2): 403-412, mar.-abr. 2020. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1098212

ABSTRACT

RESUMO Água do mar é comumente utilizada como fluido de injeção em plataformas offshore na recuperação secundária do petróleo. Porém, a presença de sulfato causa diversos inconvenientes, como a formação de precipitados, que podem se depositar em diversas partes da plataforma de produção. Atualmente, a dessulfatação é realizada em unidades removedoras de sulfato (URS) por processo de nanofiltração (NF), cujas amostras precisam ser pré-tratadas, usualmente em filtros cartuchos. Os sólidos suspensos e os microrganismos que não foram retidos pelo sistema de filtração podem depositar sobre a superfície das membranas de NF, diminuindo a produtividade do sistema e reduzindo o tempo de vida das membranas. O processo de microfiltração (MF) pode ser utilizado como pré-tratamento alternativo e possibilitaria a remoção desses elementos. Neste estudo, foi desenvolvido um processo combinado de MF e NF para a dessulfatação da água do mar, visando a sua injeção em reservatórios de petróleo. Módulos de permeação contendo membranas de poli(imida) no formato de fibras ocas foram utilizados na construção de um sistema piloto de MF integrado a um sistema piloto de NF similar aos já atualmente utilizados nas plataformas. O desempenho dos sistemas foi avaliado por meio do acompanhamento da permeabilidade de ambos durante a filtração da água do mar. Parâmetros como grau de recuperação de água, frequência e eficiência de procedimentos de retrolavagem e limpeza química também foram estudados. Os resultados demonstraram que o pré-tratamento da água do mar por MF é uma alternativa eficaz para a dessulfatação por NF.


ABSTRACT Seawater is commonly used in offshore platforms as an injection fluid in secondary oil recovery. However, the sulfate found in seawater has been the cause of many inconveniences, such as the formation of precipitates, which can settle in various parts of the production platform. Nowadays, nanofiltration (NF) is used in sulfate removal units for seawater desulfation, where cartridge filters are commonly used for seawater pretreatment. Suspended solids and microorganisms that have not been retained by the filtration system may deposit on the surface of NF membranes, decreasing system productivity and reducing membrane life. The microfiltration (MF) process can be used as an alternative pretreatment and would allow the removal of these elements. In this study, a combined process of MF and NF for seawater desulfation was developed for injection into oil reservoirs. Permeation modules containing hollow fiber shaped poly (imide) membranes were used in the construction of an MF pilot system, integrated with an NF pilot system similar to those already used on platforms. The performance of the systems was evaluated by monitoring the permeability of both during seawater filtration. Parameters such as degree of water recovery, frequency, and efficiency of backwash procedures and chemical cleaning were also studied. The results showed that MF seawater pretreatment is an effective alternative for NF desulfation.

3.
Eng. sanit. ambient ; 24(4): 719-725, jul.-ago. 2019. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1039788

ABSTRACT

RESUMO O objetivo deste trabalho foi discutir os principais parâmetros de controle de um sistema de membranas de microfiltração para remoção de óleo de efluentes com base em ensaios experimentais. Os ensaios utilizaram efluentes sintéticos com diâmetros de gotas de óleo entre 4 e 8 µm. As membranas usadas foram do tipo fibra oca com módulo submerso. Foram testados os seguintes parâmetros: concentrações de óleos e graxas na alimentação das membranas (O&Gam) entre 100 e 260 mg.L-1; taxas de recuperação de água (Rec) de 0,75 e 0,90; e pressões através das membranas (Δp) de -0,20 e -0,30 bar. Os resultados mostraram que as membranas produzem um permeado com uma qualidade boa a ponto de possibilitar o seu reúso em atividades industriais diversas. Foi também observado que a elevação da O&Gam e da Rec acentuam o declínio de fluxo com o tempo e que a elevação da Δp aumenta o valor do fluxo no tempo de seis horas.


ABSTRACT The aim of this paper is to discuss the main control parameters of a microfiltration membranes system for oil removal from effluent on experimental bases. The experiments were conducted by using synthetic effluent with oil droplets diameter ranging from 4 to 8 microns. The membranes used were hollow fiber-type which were assembled in a submerged module. The following parameters were tested: Oil and grease concentration in the feed stream (O&Gf ) of 100 and 200 mg.L-1, Water recovery rates (WRR) of 0.75 and 0.90, and Transmembrane pressure (TMP) of -0.20 and -0.30 bar. The results showed that the membranes produced a permeate with a good quality to the point of enabling their reuse in several industrial activities. It was also observed that the elevation of O&Gf and WRR increase the flux decline over time and that the increase of TMP increases the flow value in time of 6 hours.

4.
Hig. aliment ; 33(288/289): 3057-3061, abr.-maio 2019. ilus, tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1482513

ABSTRACT

No processo de fabricação de queijos a salga é uma etapa de grande importância, um dos métodos mais utilizados é a imersão em salmoura. Pensando no custo benefício e qualidade do produto vem sendo utilizado o sistema de microfiltração para regeneração de salmoura permanente, que consiste na filtragem através de membranas, permitindo o uso contínuo da salmoura. Diante disso, realizou-se uma avaliação da eficiência do tratamento de salmoura, utilizada na fabricação dos queijos tipo mussarela, provolone, prato e parmesão, através do sistema de microfiltração. Foram coletadas amostras de salmoura e realizadas análises físico-químicas e microbiológicas para monitoramento diário durante o período de três meses. Os resultados obtidos foram satisfatórios podendo observar que não houve variação significativa das análises físico-químicas e que os efeitos são benéficos na estabilidade das análises microbiológicas.


Subject(s)
Good Manufacturing Practices , Food Preservation/methods , Filtration/methods , Cheese/analysis , Identity and Quality Standard for Products and Services
5.
Eng. sanit. ambient ; 18(1): 65-74, jan.-mar. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-676959

ABSTRACT

O processo de branqueamento é o estágio em que ocorre a maior perda de fibras durante a fabricação de polpa celulósica. Além de ser uma perda de produto, estas fibras aumentam a concentração de matéria orgânica do efluente dificultando seu tratamento. O objetivo deste trabalho foi avaliar o emprego de microfiltração (MF) na remoção de fibras de efluente de branqueamento alcalino de polpa celulósica. Foi empregada membrana de poli(éter imida) com tamanho médio de poros de 0,5 µm e área de filtração de 0,05 m². O efeito das condições operacionais no fluxo permeado foi avaliado através do monitoramento do perfil de fluxo durante a operação em diferentes condições de velocidade de escoamento (Reynolds de 1.226, 1.653 e 2.043), pH da alimentação (7, 10 e 10,6), temperatura (28, 43 e 48°C) e pressão de operação através da avaliação da pressão crítica. Os resultados mostraram que a MF é um processo eficiente para remoção de fibras, apresentado 99% eficiência de remoção de sólidos suspensos. O melhor desempenho da operação de MF foi obtido empregando pH 7, pressão de 1 bar e Re de 1.653. Os resultados mostram que a redução do fluxo se deve principalmente à formação de torta.


The bleaching process is the stage where there is the greatest loss of fibers during the pulp production. Besides being a waste of product, these fibers increase the concentration of organic matter in the effluent and make the treatment of effluent more difficult. The aim of this study was to evaluate the use of microfiltration (MF) in the removal of fiber of effluent of alkaline bleaching pulp mill. The membrane employed was hollow fiber poly (ether imide), with average pore size of 0.5 µm and filtration area of 0.05 m². The effect of operating conditions on the permeate flux was evaluated by monitoring the flux profile during operation in different conditions of flow velocity (Reynolds 1,226, 1,653 and 2,043), pH of feeding (7, 10 and 10.6), temperature (28, 43, and 48°C) and pressure operation by evaluating the critical pressure. The results showed that MF is an efficient process for removal of fiber, with 99% removal efficiency of suspended solids. The best performance of the operation of MF was obtained using pH 7, 1 bar and Reynolds number of 1,653. The results show that the flow reduction is mainly due to cake formation.

6.
Eng. sanit. ambient ; 16(4): 379-386, out.-dez. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-614702

ABSTRACT

Uma alternativa atrativa para o tratamento de lixiviado de aterro sanitário são os processos oxidativos avançados empregando o reagente de Fenton (POA/Fenton). No entanto, a aplicação do POA/Fenton é limitada pela geração de lodo no processo. Esse lodo possui elevada concentração de ferro, o que torna necessária sua separação do efluente tratado. O objetivo desse trabalho foi avaliar a microfiltração para a remoção de lodo gerado no POA/Fenton. A pesquisa foi desenvolvida em unidade de bancada. O POA/Fenton apresentou elevada eficiência na remoção de matéria orgânica (75 por cento) e cor real (95 por cento). O processo de microfiltração foi eficiente na separação do lodo gerado, o qual apresentou baixa sedimentabilidade, dificultando sua separação por sedimentação, além de ter contribuído para a remoção de outros poluentes.


Advanced oxidation processes using Fenton's reagent (AOP/Fenton) are an attractive alternative for landfill leachate treatment. However, the implementation of the AOP/Fenton is limited by the generation of sludge in the process. The sludge has a high iron concentration, which needs its separation from the treated effluent. The aim of this study was to evaluate the microfiltration for sludge removal from an AOP/Fenton. The work was conducted in bench scale. The advanced oxidation process showed high efficiency in removing organic matter (75 percent) and true color (95 percent). The microfiltration was effective in separating the sludge, which showed low settling hindering their separation by sedimentation, and has contributed to the removal of other pollutants.

7.
Eng. sanit. ambient ; 15(1): 11-18, jan.-mar. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-545393

ABSTRACT

O objetivo deste artigo foi avaliar o desempenho de filtro anaeróbio em associação à membrana de microfiltração no tratamento de lixiviado de aterro sanitário. Os resultados obtidos indicaram que é possível tratar lixiviado com essa configuração de MBR (do inglês membrane bioreactor) com um tempo de detenção hidráulica de 2,04 dias. O valor médio da demanda química de oxigênio (DQO) foi 10.359 mg O2/L na entrada dos reatores, e a carga orgânica volumétrica aplicada aos reatores foi de 5,07 ± 2,90 kg DQO/m³.d. A eficiência média de remoção de DQO do filtro anaeróbio associado à membrana foi de 90,4 por cento contra 21,5 por cento do filtro anaeróbio. A eficiência de remoção de turbidez no filtro anaeróbio associado à membrana de microfiltração foi de 90,3 por cento, apresentando valores de saída de 2,0 ± 2,0 NTU. A velocidade ascensional foi de 0,05 m/h no filtro anaeróbio e 31,5 m/h no filtro anaeróbio associado à membrana, o que resultou em um número de Reynolds calculado de 2,9 e 1.799, respectivamente.


The objective of this paper was to evaluate the performance of anaerobic filter associated with a microfiltration membrane, treating landfill leachate. The results obtained showed that it is possible to treat wastewater using this MBR configuration with a hydraulic retention time of 2.04 days. The average values of organic volumetric load were 5.07 ± 2.90 kg COD/m³.d at the inlet of both reactors. The efficiencies of chemical oxygen demand (COD) removal were 90.4 percent to the anaerobic filter associated with microfiltration and 21.5 percent to the anaerobic filter. The turbidity removal was 90.3 percent to the MBR configuration with average values at the outlet of 2.0 ± 2.0 NTU. Values of upflow velocity of 31.5 m/h were reported in the anaerobic filter associated with microfiltration membrane and 0.05 m/h in the anaerobic filter which promoted a Reynolds number of 2.9 and 1,799, respectively.

SELECTION OF CITATIONS
SEARCH DETAIL