Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Einstein (Säo Paulo) ; 12(3): 295-299, Jul-Sep/2014. tab, graf
Article in English | LILACS | ID: lil-723928

ABSTRACT

Objective To correlate arrhythmic symptoms with the presence of significant arrhythmias through the external event monitoring (web-loop). Methods Between January and December 2011, the web-loop was connected to 112 patients (46% of them were women, mean age 52±21 years old). Specific arrhythmic symptoms were defined as palpitations, pre-syncope and syncope observed during the monitoring. Supraventricular tachycardia, atrial flutter or fibrillation, ventricular tachycardia, pauses greater than 2 seconds or advanced atrioventricular block were classified as significant arrhythmia. The association between symptoms and significant arrhythmias were analyzed. Results The web-loop recorded arrhythmic symptoms in 74 (66%) patients. Of these, in only 14 (19%) patients the association between symptoms and significant cardiac arrhythmia was detected. Moreover, significant arrhythmia was found in 11 (9.8%) asymptomatic patients. There was no association between presence of major symptoms and significant cardiac arrhythmia (OR=0.57, CI95%: 0.21-1.57; p=0.23). Conclusion We found no association between major symptoms and significant cardiac arrhythmia in patients submitted to event recorder monitoring. Event loop recorder was useful to elucidate cases of palpitations and syncope in symptomatic patients. .


Objetivo Correlacionar sintomas arrítmicos com a presença de arritmias significativas por meio do monitor de eventos externo (web-loop). Métodos Entre janeiro e dezembro de 2011, o web-loop foi instalado em 112 pacientes (46% mulheres, 52±21 anos). Sintomas específicos foram definidos como palpitação, pré-síncope e síncope, presentes durante a monitorização. Arritmia significativa foi definida como taquicardia paroxística supraventricular, flutter e fibrilação atrial, taquicardia ventricular, pausas superiores a 2 segundos ou bloqueio atrioventricular avançado. A associação entre presença de sintomas e arritmias significativas foi avaliada. Resultados O monitor de eventos registrou sintomas específicos em 74 (66%) pacientes, entretanto a associação entre sintomas específicos e arritmia significativa foi observada em apenas 14 (19%) deles. Em 11 pacientes (9,8%), foi detectada arritmia significativa na ausência de sintomas. Não houve associação entre a presença de sintomas e a detecção de arritmia significativa (OR=0,57, IC95%: 0,21-1,57; p=0,23). Conclusão Em pacientes monitorizados pelo web-loop, não houve associação entre a presença de sintomas específicos e a detecção de arritmias significativas. O monitor de eventos pode ter importância na elucidação de sintomas de palpitações e síncope dos pacientes. .


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Middle Aged , Young Adult , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Electrocardiography, Ambulatory/instrumentation , Syncope/diagnosis , Syncope/physiopathology , Arrhythmias, Cardiac/etiology , Chi-Square Distribution , Electrocardiography, Ambulatory/methods , Reproducibility of Results , Time Factors
2.
Rev. bras. ter. intensiva ; 26(1): 28-35, Jan-Mar/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-707204

ABSTRACT

Objetivo: Definir as características e mensurar o tempo estímulo-resposta da equipe de saúde aos alarmes de monitorização na terapia intensiva. Métodos: Estudo de abordagem quantitativa, observacional, descritivo, desenvolvido na unidade coronariana de um hospital público de cardiologia no Rio de Janeiro (RJ). Os dados foram extraídos de informações referentes aos pacientes, monitorização utilizada e da medição do tempo estímulo-resposta da equipe aos alarmes dos monitores multiparamétricos por observação de campo não participativa. Resultados: Acompanhamos 88 pacientes (49 no serviço diurno e 39 no serviço noturno). O número total de alarmes de monitorização foi de 227 nas 40 horas de observação (20 horas no serviço diurno e 20 horas no serviço noturno), 106 alarmes no serviço diurno e 121 no serviço noturno, numa média de 5,7 alarmes/hora. Foram observados 145 alarmes sem resposta da equipe, 68 (64,15%) alarmes no serviço diurno e 77 (63,64%) no serviço noturno. Demonstramos que mais de 60% dos alarmes excederam o tempo-resposta de 10 minutos, considerados alarmes sem resposta. Obtivemos uma mediana de temporesposta dos alarmes atendidos de 4 minutos e 54 segundos no serviço diurno e 4 minutos e 55 segundos no serviço noturno. A monitorização da respiração encontrava-se ativada em apenas 9 pacientes (23,07%) no serviço noturno. Em relação à habilitação dos alarmes dessas variáveis, o alarme de arritmia estava habilitado em somente 10 (20,40%) dos pacientes no serviço diurno e o alarme da respiração em 4 pacientes (44,44%) no serviço noturno. Conclusão: A programação e configuração de variáveis fisiológicas monitorizadas e parâmetros de ...


Objective: To define the characteristics and measure the reaction time of a health care team monitoring alarms in the intensive care unit. Methods: A quantitative, observational, and descriptive study developed at the coronary care unit of a cardiology public hospital in Rio de Janeiro state (RJ). Data were obtained from the information collected on the patients, the monitoring used, and the measurement of the team's reaction time to the alarms of multi-parameter monitors during a non-participatory field observation. Results: Eighty-eight patients were followed (49 during the day shift and 39 during the night shift). During the 40 hours of observation (20 hours during the day shift and 20 hours during the night shift), the total number of monitoring alarms was 227, with 106 alarms during the day shift and 121 during the night shift, an average of 5.7 alarms/hour. In total, 145 alarms unanswered by the team were observed, with 68 occurring during the day shift (64.15%) and 77 during the night shift (63.64%). This study demonstrated that the reaction time was longer than 10 minutes in more than 60% of the alarms, which were considered as unanswered alarms. The median reaction time of the answered alarms was 4 minutes and 54 seconds during the day shift and 4 minutes and 55 seconds during the night shift. The respiration monitoring was activated in only nine patients (23.07%) during the night shift. Regarding the alarm quality of these variables, the arrhythmia alarm was qualified in only 10 (20.40%) of the day-shift patients and the respiration alarm in four night-shift patients (44.44%). Conclusion: The programming and configuration of the physiological variables monitored and the parameters of alarms in the intensive care unit were inadequate; there was a delay and lack of response to the alarms, suggesting that relevant alarms may have been ignored by the health care team, thus compromising the patient safety. .


Subject(s)
Humans , Clinical Alarms , Critical Care/methods , Patient Care Team/statistics & numerical data , Brazil , Coronary Care Units/organization & administration , Hospitals, Public , Intensive Care Units , Monitoring, Physiologic/instrumentation , Patient Care Team/organization & administration , Time Factors
3.
Rev. bras. ter. intensiva ; 25(4): 306-311, Oct-Dec/2013. tab, graf
Article in Portuguese | LILACS | ID: lil-701410

ABSTRACT

Objetivo: Comparar os escores resultantes da escala Comfort-B com o índice biespectral, em crianças de uma unidade de terapia intensiva. Métodos: Onze crianças com idades entre 1 mês e 16 anos, submetidas a ventilação mecânica e sedação, foram classificadas pelo índice biespectral e pela escala Comfort-B, simultaneamente. Foi obtido registro de seus comportamentos por filmagem digital; posteriormente tal registro foi avaliado por três observadores independentes e foram aplicados testes de concordância (Bland-Altman e Kappa). Foi testada a correlação entre os dois métodos (correlação de Pearson). Resultados: Foram realizadas 35 observações em 11 pacientes. A concordância entre os avaliadores, segundo o coeficiente de Kappa, variou de 0,56 a 0,75 (p<0,001). Houve associação positiva e regular entre índice biespectral e Comfort-B, com r=0,424 (p=0,011) até r=0,498 (p=0,002). Conclusão: Devido à alta concordância entre os avaliadores independentes e a correlação regular entre os dois métodos, conclui-se que a escala Comfort-B é reprodutível e útil na classificação do nível de sedação de crianças em ventilação mecânica. .


Objective: Compare the scores resulting from the Comfort-B scale with the bispectral index in children in an intensive care unit. Methods: Eleven children between the ages of 1 month and 16 years requiring mechanical ventilation and sedation were simultaneously classified based on the bispectral index and the Comfort-B scale. Their behavior was recorded using digital photography, and the record was later evaluated by three independent evaluators. Agreement tests (Bland-Altman and Kappa) were then performed. The correlation between the two methods (Pearson correlation) was tested. Results: In total, 35 observations were performed on 11 patients. Based on the Kappa coefficient, the agreement among evaluators ranged from 0.56 to 0.75 (p<0.001). There was a positive and consistent association between the bispectral index and the Comfort-B scale [r=0.424 (p=0.011) to r=0.498 (p=0.002)]. Conclusion: Due to the strong correlation between the independent evaluators and the consistent correlation between the two methods, the results suggest that the Comfort-B scale is reproducible and useful in classifying the level of sedation in children requiring mechanical ventilation. .


Subject(s)
Adolescent , Child , Child, Preschool , Female , Humans , Infant , Male , Conscious Sedation/classification , Hypnotics and Sedatives/administration & dosage , Respiration, Artificial , Consciousness Monitors , Cross-Sectional Studies , Intensive Care Units, Pediatric , Photography , Reproducibility of Results
4.
Rev. bras. ter. intensiva ; 23(2): 238-241, abr.-jun. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-596449

ABSTRACT

São descritos os objetivos de redução da pressão intra-abdominal e o projeto de um dispositivo que os atenda. O ABDO-PRE compreende, pela primeira vez, um mecanismo de servo-controle de aplicação externa que mede a pressão intravesical como variável de controle. São apresentados os resultados da aplicação em 4 pacientes com hipertensão intra-abdominal, produzindo uma redução de 16 por cento a 35 por cento em três casos e um aumento paradoxal da pressão em um dos casos, devido a um desajuste entre a geometria da câmara de vácuo e a alteração anatômica acarretada pela obesidade da paciente. Estes resultados são promissores em relação ao possível uso do ABDOPRE na prática clínica para redução da hipertensão intra-abdominal.


Se describen los objetivos de reducción de la presión intraabdominal y el proyecto de un dispositivo que los cumpla. ABDOPRE comprende por primera vez un mecanismo servcocontrolado de aplicación externa que toma la presión intravesical como variable de control. Se presenta el resultado de la aplicación en 4 pacientes afectados por hipertensión intraabdominal, con el resultado de una reducción de entre 16 por ciento y 35 por ciento en tres casos y de un aumento paradojal de presión en un caso debido a desajuste de la geometría de la campana de vacío a la anatomía obesa del paciente. Estos resultados prometen el posible uso de ABDOPRE para la reducción de la hipertensión intraabdominal en la práctica clínica.


This article describes a device for the reduction of intra-abdominal pressure. The device (ABDOPRE) includes a unique external servo-control mechanism, based on urinary bladder pressure measurement. The results of ABDOPRE use in the first four intra-abdominal hypertension patients are reported; the device resulted in a reduction of intra-abdominal pressure between 16 percent and 35 percent in 3 cases and in a paradoxical increase of the intra-abdominal pressure in an obese woman, likely due to inappropriate chamber size for the patient's anatomy. These results are promising and ABDOPRE may be useful in clinical practice.

SELECTION OF CITATIONS
SEARCH DETAIL