Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
São Paulo med. j ; 140(3): 474-485, May-June 2022. tab, graf
Article in English | LILACS | ID: biblio-1377386

ABSTRACT

ABSTRACT BACKGROUND: The thrombin generation test (TGT) has shown promise for investigation of hemorrhagic and thrombotic diseases. However, despite its potential, it still needs standardization. Moreover, few studies have established reference values for TGT parameters. In Brazil, these values have not yet been established. OBJECTIVE: To determine TGT performance and reference intervals for TGT parameters in healthy individuals. DESIGN AND SETTING: Cross-sectional study conducted among participants in the Brazilian Longitudinal Study of Adult Health (Estudo Longitudinal de Saúde do Adulto, ELSA-Brasil). METHODS: The reference sample consisted of 620 healthy individuals. The calibrated automated thrombogram (CAT) method, under low and high tissue factor (TF) conditions, was used to assess thrombin generation. Test performance was analyzed using intra and interassay coefficients of variation (CV) and reference intervals were calculated using the nonparametric method proposed by the International Federation of Clinical Chemistry and the Clinical and Laboratory Standards Institute. RESULTS: The intraassay CV ranged from 1.4% to 2.2% and the interassay CV, 6.8% to 14.7%. The reference intervals for TGT parameters under low and high TF conditions were, respectively: lagtime: 3.0-10.3 and 1.4-3.7 min; endogenous thrombin potential (ETP): 1134.6-2517.9 and 1413.6-2658.0 nM.min; normalized ETP: 0.6-1.3 and 0.7-1.4; peak: 103.2-397.7 and 256.4-479.0 nM; normalized peak: 0.3-1.3 and 0.7-1.2; and time-to-peak: 5.6-16.0 and 3.4-6.7 min. These parameters were categorized relative to sex. Conclusion: TGT performance was adequate and the proposed reference intervals were similar to those of other studies. Our findings may be useful for consolidating the TGT, through contributing to its standardization and validation.


Subject(s)
Humans , Thrombin , Reference Values , Brazil , Cross-Sectional Studies , Longitudinal Studies
2.
Article | IMSEAR | ID: sea-225696

ABSTRACT

Aim:To determine hematological profile of eligible blood donors at Kenyatta National Hospital (KNH), Kenya.Study Design:Adopted a cross-sectional study.Place and Duration of Study:Kenyatta National Hospital, between March 2021 and August 2021.Methodology:This study recruited 202 eligible blood donors comprising of 173 males and 29 females aged 18-57 years. Blood samples (4ml) were drawn from donated units into ethylene diamine tetraacetic acid (EDTA) tube. Hematological parameters were estimated using a complete blood count (CBC) analyzer (Humacount 5D®). A total of eighteen hematological parameters were analyzed. These parametersincluded; red blood cell (RBC) count, hemoglobin concentration, RBC indices, white blood cell (WBC) count, absolute and differential WBC and platelet (PLT) count. Results were presented in medians and 95% interquartile ranges and compared using Mann–Whitney U test.Results:The median counts for all hematological parameters were within the accepted reference ranges for the adult urban population in Kenya. The median and interquartile range for total red cell count was 4.9×106/μL [0.74], hemoglobin level was 14.3g/dL[1.8], hematocrit was 44.9% [5.1], white blood count was 4.9×103/μL [1.4] and platelet was 234×103/L [64]. Among the red cell parameters analyzed, male donors had a significantly higher RBC count (P<0.001), hematocrit (P=0.001) and hemoglobin (P<0.001) than female donors. Among white blood cell parameters analyzed, only lymphocytes (P=0.011) were significantly higher in female donors than male donors. Platelet count (P<0.001) was also significantly higher in females than male donors.Conclusion:This study showed eligible donors at KNH had significant differences in red cell count, hematocrit, hemoglobin, lymphocytes and platelets between male and female donors. Additionally, it highlighted that some blood donors had hematological parameters belowand above the recommended reference ranges. These findings support the need to review the current donor recruitment criteria recommending the inclusion of complete blood count in screening.

3.
West Indian med. j ; 69(4): 201-206, 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1515648

ABSTRACT

ABSTRACT Objective: To measure the Achilles tendon length, thickness and cross-sectional area in asymptomatic adult Saudi participants and to investigate the possible changes in these measurements based on their different ages and body height. Methods: The prospective cohort study was done between January 2014 and March 2015. A total of 200 asymptomatic participants with 175 males (87.5%) and 25 females (12.5%) between the ages of 14 and 65 years, with the mean age of 25 ± 1.5 years, were scanned at two radiology departments. Ultrasound (US) scans for the Achilles tendons were performed using a Hitachi (EZU-MT30-S1 HI Vision Avius, Hitachi, Japan) US machine. Statistical Package for the Social Sciences (SPSS Inc., Chicago, IL, USA) was used to analyse the results. Results: There was no significant difference in the length, cross-sectional area and thickness of the Achilles tendons among the participants of different ages; however, the cross-sectional area of Achilles tendons of the older participants (≥ 47 years) was higher than that of the participants of the younger age groups. Moreover, there was no correlation between the length, cross-sectional area, and thickness of the Achilles tendons and their body heights; however, the participants of ≥ 153 cm in height showed an increase in their Achilles tendon cross-sectional areas. Conclusion: Ultrasound is a useful imaging tool in the assessment of the Achilles tendons. The normal variations of the tendon morphological characteristics should be considered in the clinical diagnosis. Additional studies on the correlations among the Achilles tendon length, thickness and cross-sectional areas of ethnicity of the participants in Saudi Arabia are suggested.

4.
Rev. bras. anal. clin ; 52(4): 337-345, 20201230. tab, ilus
Article in Portuguese | LILACS | ID: biblio-1223688

ABSTRACT

Em humanos, o pH sanguíneo é mantido em uma faixa estreita, entre 7,35 e 7,45. Diferentes mecanismos bioquímicos, de forma harmônica, atuam para a manutenção do pH fisiológico. Múltiplos processos patológicos podem promover alterações no pH e nos gases sanguíneos, caracterizando acidose (pH <7,35) ou alcalose (pH >7,45). A ruptura da homeostasia do pH é identificada pela medição do pH, pressão parcial de dióxido de carbono (pCO2), concentração do bicarbonato (HCO3-) e, adicionalmente, com a pressão de oxigênio (pO2) em sangue arterial, processo descrito como gasometria arterial. Este artigo revisa os principais elementos associados a compreensão das alterações e tem como objetivo central apresentar uma abordagem didática e intuitiva para a caracterização destes distúrbios; e também comenta sobre ferramentais digitais destinadas a interpretações das alterações da gasometria arterial que também são abordados, como programas para computadores em ambiente web e aplicativos para telefonia móvel.


In humans, blood pH is kept in a narrow range, between 7.35 to 7.45. Different biochemical mechanisms, in a harmonic way, act to maintain the physiological pH. Multiple pathological processes can promote changes in pH and blood gases, characterizing acidosis (pH <7.35) or alkalosis (pH> 7.45). The rupture of pH homeostasis is identified by measuring pH, partial pressure of carbon dioxide (pCO2), bicarbonate concentration (HCO3 - and, in addition, with the pressure of oxygen (pO2) in arterial blood, a process described as gasometry arterial. This article reviews the main elements associated with the understanding of acid-base changes and aims to present a didactic and intuitive approach to the characterization of these disorders; and also comments on digital tools for the interpretation of alterations in arterial blood gases are also covered, such as programs for computers in a web environment and applications for mobile phone.


Subject(s)
Reference Values , Acid-Base Imbalance , Blood Gas Analysis , Software , Mobile Applications
5.
Rev. biol. trop ; 68(4)2020.
Article in English | LILACS, SaludCR | ID: biblio-1507734

ABSTRACT

Introduction: Body size is an essential trait for endotherms to face the physiological requirements of cold, so there is a tendency to large body size at high altitudes and latitudes, known as Bergmann's rule. However, the validity of this ecomorphological rule to small-bodied endotherms across altitudinal gradients is poorly known. Objective: To understand the effects of environmental variation on body size, we assessed whether interspecific variation in body size of small tropical endotherms follows Bergmann's rule along tropical altitudinal gradients. Methods: We compiled data on elevational ranges and body masses for 133 species of hummingbirds of Colombia. We then assessed the association between body mass and mid-point of the altitudinal distribution using phylogenetic generalized least squares (PGLS) analyses under different evolutionary models. Results: We found a decelerating rate of evolution for body size since the Early Burst model of evolution provided a better fit to body mass data. For elevational range, we found a slow and constant rate since Pagel's lambda model provided a better fit to the mid-point of the altitudinal distribution data. Besides, phylogenetic regression analysis indicated that body mass and the altitudinal range of hummingbirds are associated through the phylogeny, with a positive but slight association (R2= 0.036). Conclusions: We found that body mass and altitude of hummingbirds are positively related, which is in agreement with expectations under Bergmann's rule. However, this association was weaker than expected for small and non-passerine birds like hummingbirds. Thus, our results suggest that environmental changes across altitudinal gradients do not strongly influence body mass in small tropical endotherms as hummingbirds.


Introducción: El tamaño corporal es un rasgo importante para determinar la respuesta de los endotermos a los requerimientos que exigen las zonas frías, por lo cual se espera una tendencia hacia el incremento del tamaño corporal al aumentar la altitud y la latitud. Sin embargo, se conoce poco acerca de la validez de esta regla ecomorfológica, conocida como la regla de Bergmann, para endotermos pequeños en gradientes altitudinales tropicales. Objetivo: Con el fin de entender los efectos de la variación ambiental sobre el tamaño corporal, se evaluó sí la variación interespecífica en la masa corporal de endotermos tropicales pequeños se ajusta a la regla de Bergmann a lo largo de gradientes de elevación. Métodos: Se compilaron datos sobre los rangos de distribución altitudinal y los tamaños corporales de 133 especies de colibríes en Colombia. Posteriormente, se evaluó la asociación entre la masa corporal y el punto medio de distribución altitudinal de los colibríes mediante análisis de mínimos cuadrados generalizados filogenéticos (PGLS) bajo diferentes modelos evolutivos. Resultados: La evolución de la masa corporal se ajustó mejor a un modelo de evolución Early Burst, mientras que el rango de elevación al modelo evolutivo lambda de Pagel; lo que indica que la tasa de evolución es desacelerada para el tamaño del cuerpo, mientras es lenta y constante para el rango de elevación. Además, el análisis de regresión filogenética indica que la masa corporal y el rango de elevación están positiva y ligeramente asociados (R2 = 0.036). Conclusiones: De acuerdo con lo esperado por la regla de Bergmann, los resultados indican que los colibríes tienden a ser más grandes a mayores altitudes. Sin embargo, esta asociación es más débil de lo esperado para aves no paseriformes de tamaño pequeño como los colibríes.Por lo tanto, los resultados sugieren que las variaciones ambientales a lo largo de gradientes de elevación no tienen una influencia fuerte sobre el tamaño corporal de endotermos pequeños como los colibríes.


Subject(s)
Animals , Body Weights and Measures , Passeriformes/growth & development , Altitude , Colombia
6.
Chinese Medical Journal ; (24): 2033-2038, 2019.
Article in English | WPRIM | ID: wpr-802846

ABSTRACT

Background@#Serum human chorionic gonadotrophin (hCG) is higher in twin than that in singleton pregnancies. As hCG stimulates the thyroid to produce more free thyroxine (FT4), which may lead to decreased thyroid-stimulating hormone (TSH) levels, the reference ranges of thyroid-related indicators may differ between singleton and twin pregnancies in the first trimester. This study aimed to establish reference ranges for thyroid-related indicators in early twin pregnancies and to compare them with singleton pregnancies.@*Methods@#Data of 820 twin-pregnant women were extracted from the established database of all pregnant women who delivered at Peking University First Hospital from October 2013 to May 2018; 160 who met National Academy of Clinical Biochemistry criteria were included to establish TSH and FT4 reference ranges. We screened 480 (3:1 paired) women with singleton pregnancies from the same database as controls. The Mann-Whitney test for TSH and FT4 levels was applied for comparisons between singleton and twin pregnancies.@*Results@#First-trimester reference ranges (4–12 gestational weeks) for twin pregnancies were: TSH 0.69 (0.01–3.35) mIU/L and FT4 16.38 (12.45–23.34) pmol/L. Median TSH was significantly lower at 7 to 12 gestational weeks than that at 4 to 6 gestational weeks (0.62 vs. 0.96 mIU/L, Z = -1.964, P = 0.049); FT4 was not significantly different between the two groups. Compared to singleton pregnancies, median TSH was significantly lower (0.69 vs. 1.27 mIU/L, Z = -6.538, P = 0.000), and FT4 was significantly higher (16.38 vs. 14.85 pmol/L, Z = -7.399, P = 0.000) in twin pregnancies in the first trimester.@*Conclusions@#Specific reference ranges for thyroid-related indicators for twin pregnancies are needed to avoid a misdiagnosis of thyroid dysfunction. Moreover, establishment of separate reference ranges for 4 to 6 and 7 to 12 gestational weeks in twin pregnancies may be considered.

7.
Rev. biol. trop ; 66(1): 227-236, Jan.-Mar. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-897667

ABSTRACT

Resumen Los reportes sobre diversidad de plantas en los bosques tropicales suelen estar restringidos a árboles u otros grupos de plantas leñosas por encima de cierto diámetro del tallo. Sin embargo, otros estudios que incluyen todas las formas de vida sin restricciones de tamaño de los individuos, indican claramente que las plantas no leñosas son igual de importantes. En este estudio se reporta la Riqueza total de especies de plantas vasculares (RTE) en una parcela de una hectárea en un bosque andino del noroccidente de Colombia (6º12'48"N & 75º29'32"O); adicionalmente evaluamos la contribución de los diferentes hábitos de crecimiento a la RTE y el efecto del tamaño de las plantas. Se censaron todos los individuos con diámetro del tronco (D) ≥ 5 cm en 1 ha, y todas las plantas vasculares de todos los tamaños, incluyendo epífitas, en una muestra de 0.25 hectáreas. Se registró un total de 14 545 individuos distribuidos en 318 especies, 72 familias (considerando Pteridophyta como un solo grupo) y 171 géneros. El 99.7 % de las especies son menores de 10 cm de (D) y el 94.4 % son menores a 2.5 cm de (D). Las especies no arbóreas (hierbas terrestres, epífitas y escandentes) representan el 54.3% del total de especies registradas en la parcela, lo que indica que son un componente clave de la estructura, composición y riqueza de este bosque montano neotropical. Estos resultados confirman reportes similares para otros bosques tropicales. Concluimos que para conocer con más detalle la diversidad de florística de un sitio es recomendable: 1) ampliar el rango de tamaño de las plantas considerado comúnmente en los inventarios florísticos y 2) incluir las especies no leñosas; esta información es crucial para tomar mejores decisiones en los esfuerzos de conservación a escala local y global.


Abstract Studies of plant diversity in tropical forests are usually restricted to trees or other groups of woody plants above a certain stem diameter. However, surveys that include all forms of live plants with no restrictions on their sizes, clearly indicate that non-woody plants are equally important. In this study, we reported the total species richness of vascular plants species (TSR) in one hectare plot in an Andean forest in Northwestern Colombia (6º12'48"N & 75º29 32"W). We evaluated the relative contribution of the different growth habits and the effect of the plant size, to TSR. We measured all individuals with diameter (D) ≥ 5 cm in the hectare and all the vascular plants of all sizes, including epiphytes, in a subsample of 0.25 ha. A total of 14 545 individuals distributed in 318 species, 72 families (considering Pteridophyta as one group) and 171 genera were registered. Most of the species showed a (D) < 10 cm (99.7 %) and < 2.5 cm (94.4 %). The no-arboreal species (ground herbs, epiphytes and vines) represented 54.3 % of the total species reported in the plot, indicating that they are important in the structure, composition and species richness of this montane forest. Our results coincide with similar studies in other tropical forests. We concluded that to get a more detailed knowledge of the floristic diversity of a site, it is advisable to: 1) amplify the size range of the plants generally considered in the floristic inventories and 2) to include non-woody species. This information is crucial for making better decisions in local and global conservation efforts. Rev. Biol. Trop. 66(1): 227-236. Epub 2018 March 01.

8.
Rev. bras. ginecol. obstet ; 39(9): 443-452, Sept. 2017. tab, graf
Article in English | LILACS | ID: biblio-898895

ABSTRACT

Abstract Objective To define transvaginal ultrasound reference ranges for uterine cervix measurements according to gestational age (GA) in low-risk pregnancies. Methods Cohort of low-risk pregnantwomen undergoing transvaginal ultrasound exams every 4 weeks, comprisingmeasurements of the cervical length and volume, the transverse and anteroposterior diameters of the cervix, and distance fromthe entrance of the uterine artery into the cervix until the internal os. The inter- and intraobserver variabilities were assessed with the linear correlation coefficient and the Student t-test. Within each period of GA, 2.5, 10, 50, 90 and 97.5 percentiles were estimated, and the variation by GA was assessed with analysis of variance for dependent samples. Mean values and Student t-test were used to compare the values stratified by control variables. Results After confirming the high reproducibility of the method, 172 women followed in this cohort presented a reduction in cervical length, with an increase in volume and in the anteroposterior and transverse diameters during pregnancy. Smaller cervical lengths were associated with younger age, lower parity, and absence of previous cesarean section (C-section). Conclusion In the studied population, we observed cervical length shortening throughout pregnancy, suggesting a physiological reduction mainly in the vaginal portion of the cervix. In order to better predict pretermbirth, cervical insufficiency and premature rupture of membranes, reference curves and specific cut-off values need to be validated.


Resumo Objetivo Elaborar curvas de referências de medidas ultrassonográficas de colo uterino por idade gestacional (IG) em gestações de baixo risco. Métodos Coorte de gestantes de baixo risco, submetidas a ultrassom transvaginal repetido a cada 4 semanas, com medida do comprimento, dos diâmetros anteroposterior e transverso, da distância entre a entrada da artéria uterina no colo e o orifício interno, e do volume do colo. Foi avaliada a variabilidade inter e intraobservador entre as medidas com o coeficiente de correlação linear e teste t de Student. Para cada faixa de IG, estimaram-se os percentis 2,5, 10, 50, 90 e 97,5 dos valores das medidas, com a variação por IG avaliada por análise de variância para amostras dependentes. As comparações dos valores por variáveis de controle foram feitas por meio dos cálculos de médias e teste t de Student. Resultados Assegurada a alta reprodutibilidade do método, as 172 mulheres acompanhadas na coorte apresentaram redução das medidas de comprimento de colo com o decorrer da gestação, com aumento de volume e dos diâmetros anteroposterior e transverso. O menor comprimento cervical foi associado à menor idade materna, menor paridade, e ausência de cesárea prévia. Conclusão Na população estudada foi observada redução no comprimento cervical com o decorrer da gestação, sugerindo encurtamento fisiológico principalmente à custa da porção vaginal do colo. Há a necessidade de validar tais curvas de referência e pontos de corte específicos para uma melhor predição de risco de parto pré-termo, insuficiência cervical, e amniorrexe prematura.


Subject(s)
Humans , Female , Pregnancy , Adult , Young Adult , Cervix Uteri/anatomy & histology , Cervix Uteri/diagnostic imaging , Ultrasonography, Prenatal/methods , Pregnancy Trimesters , Reference Values , Vagina , Prospective Studies , Risk Assessment
9.
Chinese Journal of Blood Transfusion ; (12): 687-689, 2017.
Article in Chinese | WPRIM | ID: wpr-607468

ABSTRACT

Objective To establish a reference range for the normal value of thromboelastography (TEG) in pregnant females.Methods According to the results of pregnancy and physical examination,166 pregnant females and 64 healthy females without pregnancy were selected as the pregnant group and the non-pregnant control group,respectively.The TEG value and the traditional coagulation index were measured.The TEG parameters of the two groups were compared and analyzed,establishing a reference range for the parameters.We further analyzed the effect of full-term pregnancy on TEG results and the correlation between traditional coagulation index and TEG test results.Results The traditional coagulation index and TEG test results of the pregnant females andthe non-pregnant females were significantly different.According to the results,a new TEG reference range was established:R 3.9-7.5 min,K 1.0-2.4 min,α 57.6°-74.9°,MA 55.7-75.7 mm,LY30 0-0.56%,CI(-0.97)-3.6.Full-term pregnancy had no significant effect on TEG results.In addition to LY30,other parameters of TEG had some correlation with the traditional coagulation index.Conclusions The general TEG reference range does not apply to pregnant females and established TEG normal reference range for pregnant females can be applied for clinical use.

10.
Chinese Journal of Blood Transfusion ; (12): 690-692, 2017.
Article in Chinese | WPRIM | ID: wpr-607383

ABSTRACT

Objective To analyze the screening results of yon Willebrand factor among patients before blood transfusion in Ruijin Hospital and discuss von Willebrand factor in ABO blood group and the relationship between age and gender,refine the classification of vWF antigen and activity by reference factors.Methods The von Willebrand factor among 247 cases of patients before blood transfusion in Ruijin Hospital with no clinical manifestations of abnormal blood clots and routine coagulation as laboratory tests for normal surgical patients.The vWF:Ag and vWF:Act were measured by immune turbidimetric method and ABO blood group was identified by blood type serology.Furthermore,the differences between A,B,O,AB different blood groups,sex and high (≥40 years) and low age group (<40 years) were compared by statistical methods.Results The levels of vWF:Ag in different blood groups were as follows:A blood type:98.5-142.00,B blood type:97.90-160.30,O blood type:82.13-125.45,A B blood type:103.00-135.80.The levels of vWF:Act in different blood groups were as follows:A blood type:76-130.14,B blood type:78.06-144.3,O blood type:60.89-116.11,AB blood type:88.99-124.09.O blood type vWF:Ag and vWF:Act were lower significantly (P<0.05) than non-O blood type,the difference was.Besides,young vWF:Ag and vWF:Act were lower significantly than in the elderly.There was no significant difference in vWF:Ag and vWF:Act levels between male and female groups.At last,the reference range of four groups of vWF activity (antigen) was obtained.Conclusion Plasma vWF antigen and activity levels were significantly affected by ABO blood type and age,and the refined reference range established for these influencing factors was beneficial for more detailed diagnosis of VWD and predicting vWF levels associated with bleeding and thrombosis risk.

11.
Chinese Journal of Interventional Imaging and Therapy ; (12): 416-421, 2017.
Article in Chinese | WPRIM | ID: wpr-616717

ABSTRACT

Objective To obtain the normal reference ranges of global longitudinal strain (GLS),global circumferential strain (GCS),global area strain (GAS) and global radial strain (GRS) of left ventricular in normal adults by three-dimensional speckle tracking imaging (3D-STI) using Meta analysis.Methods Eligible trials which detected global strain of left ventricular in normal subject through 3D-STI were searched in Embase,Pubmed,Cochrane Library database.According to the heterogeneity,parameters of contained studies were analyzed the weighted mean difference (WMD) and 95% confidence interval (CI).The statistical software was STATA 12.0.Results Totally 1 552 healthy adults from 27 articles were included.Based on the Meta-analysis,theWMDand 95%CIofGLSwere 17.80 and (16.27,19.33),of GCS were 24.73 and (22.50,26.95),of GRS were 47.86 and (39.52,56.19),of GAS were 36.17 and (34.08,38.26).Conclusion The Meta analysis defines reference range of strains obtained by 3D-STI in healthy adults.Using these parameters of 3D globe strains,a guidance of reference for patienfs management and therapy selection may be provided.

12.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1506501

ABSTRACT

La investigación presentada a continuación trata sobre los estereotipos que tiene la población acerca del Psicólogo, de sus roles y funciones y la influencia que tienen estos estereotipos al momento de la búsqueda de ayuda profesional en la ciudad de La Paz. Se trabajó con el método cualitativo utilizando como técnica de recopilación de información los Grupos Focales, mismos que se dividieron por rangos de edad. Es importante tanto para los profesionales en psicología, como para los estudiantes y población en general el conocer los estereotipos que se manejan, sean estos positivos o negativos, ya que solo así se puede expandir el campo de intervención del psicólogo y planificar estrategias que permitan acercarse más a la población. Según los resultados obtenidos se puede evidenciar la existencia de una relación entre los estereotipos y la búsqueda de ayuda profesional pero que además está ligado a otros factores, además en el presente artículo se hace una análisis de cómo se podrían cambiar esos estereotipos y recomendaciones de futuros estudios con respecto al tema.


The research presented below deals with the stereotypes that the population has aboutthe Psychologist, their roles and functions and the influence of these stereotypes when seeking professional help in the city of La Paz. The qualitative method was used, using the Focal Groups as a technique for gathering information, which were divided by age group. It is important both for professionals in psychology, as for students and the population in general, to knowthe stereotypes that are handled, whether positive or negative, since this is the only way to expand the field of intervention of the psychologist and plan strategies to get closer more to the population. According to the results obtained, the existence of a relationship between stereotypes and the search for professional help can be evidenced, but it is also linked to other factors, and in this article an analysis is made of how those stereotypes and future recommendations could be changed studies regarding the subject.


A pesquisa apresentada abaixo trata dos estereótipos que a população tem sobre o psicólogo, seus papéis e funções e a influência desses estereótipos ao procurar ajuda profissional na cidade de La Paz. O método qualitativo foi utilizado, utilizando os Grupos Focais como técnica de coleta de informações, que foram divididos por faixa etária. É importante tanto para os profissionais em psicologia quanto para os estudantes e a população em geral, conhecer os estereótipos que são tratados, sejam positivos ou negativos, uma vez que este é o único meio de expandir o campo de intervenção do psicólogo e planejar estratégias para se aproximar mais para a população. De acordo com os resultados obtidos, a existência de uma relação entre estereótipos e busca de ajuda profissional pode ser evidenciada, mas também está relacionada a outros fatores, e neste artigo é feita uma análise de como esses estereótipos e futuras recomendações poderiam ser alterados Estudos sobre o assunto.

13.
Arch. argent. pediatr ; 114(4): 329-336, ago. 2016. graf, tab
Article in English, Spanish | LILACS, BINACIS | ID: biblio-838241

ABSTRACT

Introducción. Existe escasa información acerca de los valores de referencia de la insulina y de los índices de insulinosensibilidad en pediatría. Objetivo. Describir la variación de insulina e índices subrogantes de insulinosensibilidad en la etapa pediátrica. Población y métodos. Variación de la concentración de insulina en ayuno y de los índices subrogantes, como el modelo de evaluación homeostática de resistencia a la insulina (homeostasis model assessment of insulin resistance; HOMA-IR, por sus siglas en inglés), en niños sanos con la edad, el índice de masa corporal, estadio puberal (EP), la concentración de IGF-I, colesterol total y triglicéridos. Resultados. Se incluyeron 226 niños sanos (1-18 años). La insulina aumentó con la edad, el índice de masa corporal, el EP, los niveles de IGF-I y triglicéridos (r²= 0,38; p 7,5 años presentaron mayores valores de insulina [mediana (Pc3 y Pc97) pUI/ mL: 5,0 (1,7-9,6)] que los prepuberales < 7,5 años [2,9 pUI/mL (1,3-10,9); p < 0,01]. En la pubertad (del EP II al EP V), la insulina fue mayor en las niñas que en los varones [(7,4 (1,8-16,9) versus 5,8 (1,8-12,9); p 7,5 años: 1,1 (0,3-2,0) versus niños < 7,5 años: 0,6 (0,3-1,4; p < 0,01). Los grupos puberales presentaron niveles más elevados de insulina y de HOMA-IR respecto de los niños prepuberales (p 2,0 y > 2,6 en prepúberes y púberes, respectivamente, podrían alertar a los pediatras sobre un posible estado de insulinorresistencia.


Introduction. Information on insulin reference values and insulin sensitivity indices in the field of pediatrics is scarce. Objective. To describe insulin range and insulin sensitivity surrogate indices during childhood. Population and methods. Fasting insulin level range and surrogate indices, such as the homeostasis model assessment of insulin resistance (HOMA-IR), among healthy children and adolescents by age, body mass index, pubertal stage (PS), insulin-like growth factor-1 (IGF-1), total cholesterol, and triglycerides. Results. Two hundred and twenty-six healthy children and adolescents (1-18 years old) were included. Insulin increased with age, body mass index, pubertal stage, IGF-1 and triglyceride levels (r²= 0.38, p 7.5 years old had higher insulin levels [median (P3 and P97) pIU/mL: 5.0 (1.7-9.6)] than prepubertal children < 7.5 years old [2.9 pIU/ mL (1.3-10.9), p < 0.01]. During puberty (from PS II to PS V), insulin was higher in girls than in boys [7.4 (1.8-16.9) versus 5.8 (1.8-12.9), p 7.5 years old: 1.1 (0.32.0) versus children < 7.5 years old: 0.6 (0.3-1.4, p < 0.01). The insulin level and HOMA-IR results were higher in pubertal children compared to the prepubertal group (p 2.0 and > 2.6 in prepubertal and pubertal children, respectively, may be considered a warning sign for pediatricians to further investigate insulin resistance.


Subject(s)
Humans , Infant , Child, Preschool , Child , Adolescent , Insulin Resistance , Insulin/blood , Reference Values , Cross-Sectional Studies
14.
Ciênc. rural ; 45(5): 939-942, 05/2015. graf
Article in Portuguese | LILACS | ID: lil-745841

ABSTRACT

Nos últimos anos, a oferta de pulverizadores autopropelidos no mercado brasileiro aumentou, principalmente para suprir a demanda de agricultores que possuem grandes extensões de áreas, nas quais se requer um alto ritmo operacional. Neste trabalho, foram avaliados, em função da potência nominal do motor, os diferentes tipos de transmissões, a capacidade do reservatório de calda, tamanho das barras e vão livre, considerados critérios técnicos importantes para a seleção dessas máquinas. Para tanto, utilizaram-se informações técnicas de 41 modelos de pulverizadores autopropelidos comercializados no mercado brasileiro. Como resultado, classificaram-se os pulverizadores em cinco classes, segundo a potência do motor. Verificou-se que, com o aumento da potência, os pulverizadores são equipados com transmissão hidrostática e a capacidade dos reservatórios de calda são maiores.


In recent years the offer of self-propelled sprayers in the Brazilian market increased mainly to supply the demand of farmers who own large areas where there are a high operational pace requirement. In this research the different kinds of transmissions, tank capacity of spray mix, width of bars and clearance, which are considered important technical criteria, were evaluated according to nominal engine power. Technical information of 41 self-propelled sprayer models commercialized in Brazilian market were used. As result, sprayers were classified in five classes, according to the engine power. It was verified that, with the increase of power, the sprayers are equipped with hydrostatic transmission and the tank capacity of spray mix are higher.

15.
Article in English | IMSEAR | ID: sea-174229

ABSTRACT

Research reports indicate that vitamin B12 levels show racial differences, which suggests that using the reference ranges of varied populations may lead to inaccurate results. This study aimed to determine normal serum levels of vitamin B12 among children and young people in the Konya region of Turkey. It evaluated 1,109 samples; 54 were from cord-blood and 1,055 were from healthy subjects aged 0-24 year(s), who were admitted to primary healthcare centres. The normal reference levels obtained for vitamin B12 at 2.5-97.5 percentile (P2.5-P97.5) range were 127-606 pg/mL for girls, 127-576 pg/mL for boys, and 127-590 pg/mL for the entire study group. The reported reference values for vitamin B12 in other studies were higher than the current results. Vitamin B12 levels vary from country to country; comparisons between countries may not be valid, and normal levels for each population should be obtained.

16.
Acta bioquím. clín. latinoam ; 48(3): 311-317, set. 2014. tab
Article in Spanish | LILACS | ID: lil-734240

ABSTRACT

Cumpliendo con el propósito fundamental de la medicina de laboratorio que es aportar al especialista información que le sea de utilidad en el proceso de decisión médica, el objetivo del trabajo fue establecer el perfil bioquímico de recién nacidos sanos de Villa Clara a través de la cuantificación de indicadores en sangre del cordón umbilical y estimar, preliminarmente, en dichos analitos sus valores de referencia para esta población. Se utilizó como muestra el suero obtenido de la sangre del cordón umbilical de 80 recién nacidos sanos (40 de sexo femenino y 40 de sexo masculino) que cumplieron los criterios de inclusión establecidos para este estudio. Se cuantificaron parámetros de química clínica (urea, creatinina, alaninamino transferasa, aspartatoamino transferasa, bilirrubina total, fosfatasa alcalina, gamma-glutamiltransferasa, colesterol, triglicéridos y VLDL), inmunológicos (inmunoglobulinas IgM, IgG e IgA, y las proteínas C3 y C4 del sistema del complemento) y de minerales (hierro, cobre, cinc sodio, potasio, magnesio y calcio). Finalmente se establecieron los valores de referencia para cada parámetro, tomando el intervalo interpercentil correspondiente al intervalo central (95%) delimitado por los percentiles 2,5 y 97,5. No se encontraron diferencias estadísticamente significativas en dependencia del sexo del recién nacido en ningún analito. Con los valores encontrados de los indicadores estudiados se obtuvo la caracterización bioquímica de neonatos en Villa Clara. Este conocimiento es un instrumento que puede permitir acceder a un rápido diagnóstico de numerosas afecciones pues, probablemente la alteración de cierto indicador comparada con su valor normal en la sangre del cordón sirva de biomarcador para detectar de forma temprana determinada enfermedad o riesgo de padecer la misma.


Taking into account the fundamental purpose of laboratory medicine, which is to provide the specialist with information that will be useful in the process of medical decision, it has been decided to establish the biochemical profile of healthy newborns of Villa Clara through the quantification of indicators in cord blood and the preliminary estimate of their reference values for our population. Sera samples were used, obtained from umbilical cord blood of 80 healthy newborns (40 females and 40 males) who met the inclusion criteria for this study. Were quantified clinical chemistry parameters (urea, creatinine, alanine aminotransferase, aspartate aminotransferase, total bilirubin, alkaline phosphatase, gamma-glutamyl transferase, cholesterol, triglycerides and VLDL). Immunological parameters (immunoglobulins IgM, IgG and IgA, and C3 and C4 proteins of the complement system) and minerals (iron, copper, zinc, potassium, magnesium and calcium) were quantified. Finally reference values for each parameter were established, taking the interval corresponding to the interpencentil center (95%) interval delimited by the 2.5 and 97.5 percentiles. No statistically significant differences were found depending on the sex of the newborn in any analyte. With the values found for the indicators studied, biochemical characterization of infants in Villa Clara was obtained. This knowledge is a tool that can enable access to rapid diagnosis of many diseases. Probably some indicator change in its value in relation to normal umbilical cord blood can serve as a biomarker for early detection of specific disease or risk.


Levando em consideração o propósito fundamental da medicina laboratorial, que é proporcionar a informação especializada ao especialista, a qual será útil no processo de decisão médica, se decidiu estabelecer o perfil bioquímico de recém-nascidos saudáveis de Villa Clara, através da quantificação de indicadores de sangue do cordão umbilical e a estimativa preliminar de seus valores de referência para esta população. Foi utilizado como amostra o soro obtido do sangue do cordão umbilical de 80 recém-nascidos saudáveis (40 de sexo masculino e 40 de sexo feminino) que preencheram os critérios de inclusão para este estudo. Foram quantificados parâmetros de química clínica (urde la feia, creatinina, alanina aminotransferase, aspartato aminotransferase, bilirrubina total, fosfatase alcalina, gama-glutamil transferase, colesterol, triglicérides e VLDL) imunológicos (imunoglobulinas IgM, IgG e IgA, e as proteínas C3 e C4 do sistema do complemento) e de minerais (ferro, cobre, zinco, sódio, potássio, magnésio e cálcio). Finalmente foram estabelecidos os valores de referência para cada parâmetro, tomando o intervalo entre percentil correspondente ao intervalo central (95%) delimitado pelos percentis 2,5 e 97,5. Não foram encontradas diferenças estatisticamente significativas em função do sexo do recém-nascido em qualquer analito. Com os valores encontrados dos indicadores estudados foi obtida a caracterização bioquímica de neonatos em Villa Clara. Este conhecimento é uma ferramenta que pode permitir o acesso a um diagnóstico rápido de inúmeras doenças, provavelmente a alteração de certo indicador comparada com seu valor normal no sangue do cordão umbilical sirva como um biomarcador para a detecção precoce de uma doença específica ou o risco de sofrer essa doença.


Subject(s)
Humans , Male , Female , Infant, Newborn , Blood Chemical Analysis/standards , Fetal Blood , Blood , Cuba , Reference Standards , Reference Values , Umbilical Cord
17.
Acta bioquím. clín. latinoam ; 48(2): 237-241, jun. 2014. graf, tab
Article in Spanish | LILACS | ID: lil-734232

ABSTRACT

El sistema hemostático varía a lo largo de las primeras etapas de vida ya que el organismo sufre un proceso dinámico de cambios durante el período de crecimiento. En la literatura existen pocos trabajos sobre valores de referencia en niños de pruebas de hemostasia y por ello la importancia de investigar en el tema. El presente es un trabajo retrospectivo que se realizó sobre 512 niños hasta 17 años que concurrieron al hospital con pedido médico de estudio prequirúrgico para cirugías programadas ambulatorias de los cuales se obtuvieron, de sus historias clínicas, los valores de actividad protrombínica del plasma (APP), tiempo de tromboplastina parcialmente activada (aPTT) y fibrinógeno. Los resultados, teniendo en cuenta el percentilo 97,5, mostraron diferencias significativas para la determinación del APP y del aPTT, no observándose diferencias en la prueba del fibrinógeno. Es importante que cada laboratorio establezca sus propios valores de referencia para estas pruebas, ya que no son extrapolables a los de los adultos. En este estudio se demuestra que el sistema hemostático sufre modificaciones durante la infancia que deben ser tenidas en cuenta para interpretar correctamente los resultados de las pruebas realizadas.


The haemostatic system varies throughout the first stages of life since the body undergoes a dynamic process of changes during the growth period. Little research has been conducted on the reference ranges of haemostasis tests in children; therefore, it is of great significance to investigate this subject. The following study is retrospective and it was conducted on 512 children up to 17 years old that attended the hospital requesting presurgical testing for scheduled ambulatory surgeries. Ranges of plasma prothrombin activity (APP), the activated partial thromboplastin time (aPTT) and fibrinogen were obtained from the patients' medical records. Taking into account the 97.5 percentile, the results showed important differences in APP and aPTT determination but showed no differences in the fibrinogen test. It is important that all laboratories establish their own reference ranges for these tests since they cannot be extrapolated to the ones in adults. This study proves that the haemostatic system undergoes significant changes during infancy which shall be taken into account for the correct interpretation of the results of the tests carried out.


O sistema hemostático varia ao longo das primeiras etapas da vida visto que o organismo sofre um processo dinâmico de alterações durante o periodo de crescimento. Na literatura existem poucos estudos sobre valores de referência de testes de hemostasia em crianças e é por esse motivo que é importante pesquisar sobre o assunto. O presente trabalho é retrospectivo e foi realizado em 512 crianças de até 17 anos que assistiram ao hospital com pedido médico de exame pré-cirúrgico para cirurgias ambulatoriais programadas, de cujos prontuários foram obtidos os valores da atividade protrombínica (APP), tempo de tromboplastina parcialmente ativada (aPTT) e fibrinogênio. Os resultados, levando em consideração o percentil 97,5, mostraram diferenças significativas para a determinação do APP e do aPTT, não encontrando diferenças no teste do fibrinogênio. É importante que cada laboratório estabeleça seus próprios valores de referência para estes testes, visto que não se pode extrapolar para os adultos. Neste estudo é demonstrado que o sistema hemostático sofre modificações na infância as quais devem ser consideradas para interpretar corretamente os resultados dos testes realizados.


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , Blood Coagulation Tests/standards , Fibrinogen , Partial Thromboplastin Time , Prothrombin Time , Quality Control , Blood Coagulation Tests , Hemostasis , Reference Values
18.
Indian J Pathol Microbiol ; 2013 Apr-Jun 56 (2): 120-124
Article in English | IMSEAR | ID: sea-155844

ABSTRACT

Since the advent of automation in the fi eld of hematological cell counters there has been a constant refi nement of the technology and increase in the number of newer parameters available on CBC analysers. Many novel parameters are being put into routine clinical use and both clinical evaluation and monitoring critically depend on knowledge of laboratory reference ranges. Here, we present reference interval for the Sysmex XE-2100, with emphasis on the novel or newer research parameters. Blood samples from a total of 122 clinically asymptomatic and apparently healthy subjects were evaluated and a fi nal of 100 subjects (54-M, 46-F) were included in the study. A broad spectrum of parameters available with the analyser was assessed and reference ranges for the same evaluated.

19.
Korean Journal of Hematology ; : 136-141, 2012.
Article in English | WPRIM | ID: wpr-720183

ABSTRACT

BACKGROUND: The objective of this study was to determine if there are differences in common red blood cell (RBC) indices and platelet concentrations during pregnancy and to establish if any observed differences in these parameters were based on the patient's ethnicity. METHODS: From an electronic perinatal database which stores laboratory and clinical information on a large number of births at a regional hospital specializing in obstetrical care, RBC index and platelet concentration data were retrospectively analyzed at various time points throughout pregnancy. RBC index data was collected from 8,277 pregnant women (5,802 Caucasian pregnant women and 2,475 non-Caucasian pregnant women). Platelet concentration data was available from 8252 pregnant women (5,784 Caucasian pregnant women and 2,468 non-Caucasian pregnant women). RESULTS: Hemoglobin (HGB) levels were significantly higher amongst Caucasian women compared to non-Caucasian women (P at least <0.01) starting at 27 weeks gestation and proceeding until term. There was no significant difference in the mean PLT counts between Caucasian and non-Caucasian pregnant women at any point during gestation. CONCLUSION: There are ethnic differences in HGB levels, but not the platelet concentrations, during pregnancy. Based on this finding it would be reasonable to conduct formal prospective studies to determine the clinical significance of this difference and to establish the threshold for diagnosing gestational anemia, especially in pregnant non-Caucasian women.


Subject(s)
Female , Humans , Pregnancy , Anemia , Blood Cell Count , Blood Platelets , Electronics , Electrons , Erythrocytes , Hemoglobins , Parturition , Pregnant Women , Reference Values , Retrospective Studies , United States
20.
Rev. bras. ginecol. obstet ; 32(9): 426-432, set. 2010. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-572646

ABSTRACT

OBJETIVO: avaliar as áreas das válvulas atrioventriculares (tricúspide e mitral) de fetos normais por meio da ultrassonografia tridimensional (US3D) utilizando o método STIC (spatiotemporal image correlation). MÉTODOS: realizou-se estudo de corte transversal com 141 mulheres entre a 18ª e a 33ª semana de gestação. As medidas dos volumes cardíacos foram obtidas por um transdutor volumétrico transabdominal acoplado ao aparelho Voluson 730 Expert. Utilizou-se como referência o plano de quatro câmaras com a ROI (região de interesse) posicionada a partir dos ventrículos, sendo a área das valvas delimitada manualmente. Para conhecer a correlação das áreas valvulares com a idade gestacional, foram construídos diagramas de dispersão e calculou-se o coeficiente de correlação de Pearson (r). Foram calculadas médias, medianas, desvios padrão (DP), valores máximo e mínimo. Para se determinar intervalos de referência das áreas valvulares em função da idade gestacional, seguiu-se o modelo de regressão linear simples, utilizando o método de Altman, com nível de significância de p<0,05. Para o cálculo da reprodutibilidade intraobservador, utilizou-se o coeficiente de correlação intraclasse (CCI) e o gráfico de Bland-Altman. RESULTADOS: as áreas valvulares tricúspide e mitral se correlacionaram com a idade gestacional (r=0,80 para a tricúspide e r=0,79 para a mitral), sendo que a média aumentou da válvula tricúspide e mitral, respectivamente, de 0,22±0,10 cm² e de 0,23±0,10 cm² na 18º semana para 0,92±0,29 cm² e para 1,08±0,41 cm² na 33º semana de gestação. A reprodutibilidade intraobservador resultou em CCI=0,993 (IC95 por cento 0,987; 0,996), com diferença média de 0,01 cm² (DP±0,2 cm² e IC95 por cento±0,4 cm²). CONCLUSÃO: intervalos de referência para a área das valvares mitral e tricúspide entre a 18ªe a 33ª semana de gestação foram determinados pela US3D e se mostraram altamente reprodutíveis.


PURPOSE: to evaluate the areas of the atrioventricular valves (tricuspid and mitral) of normal fetuses by the use of three-dimensional ultrasound (3DUS) and the spatiotemporal image correlation (STIC) method. METHODS: a cross-sectional study was conducted on 141 women between the 18th and the 33rd week of pregnancy. Cardiac volumes were measured with a volumetric transabdominal transducer attached to the Voluson 730 Expert equipment. The four chamber plane was used as reference, with the region of interest (ROI) positioned from the ventricles, and the area of the valves was obtained manually. To determine the correlation of the areas with gestational age, scatter plots were constructed and the Pearson correlation coefficient (r) was calculated. Means, medians, standard deviations (SD) and maximum and minimum values were calculated. The simple linear regression model was used to determine reference ranges of valve areas according to the gestational age by the Altman method, with the level of significance set at p<0.05. To calculate the intraobserver reproducibility, we used the intraclass correlation coefficient (ICC) and the Bland-Altman graph. RESULTS: the mitral and tricuspid valve areas were correlated to the gestational age (r=0.80 for the tricuspid and r=0.79 for the mitral valve) and the mean value of the tricuspid and mitral valves increased from 0.22±0.10 cm² and 0.23±0.10 cm² on the 18th week to 0.92±0.29 cm² and 1.08±0.41 cm² on the 33rd of pregnancy, respectively. The intraobserver reproducibility resulted in an ICC=0.993 (95 percentCI 0.987; 0.996) and the mean difference was 0.01 cm² (SD±0.2 cm² and CI95 percent±0.4 cm²). CONCLUSION: reference intervals for the areas of the mitral and tricuspid valve between the 18th and the 33rd week of gestation were determined and proved to be highly reproducible.


Subject(s)
Adolescent , Adult , Female , Humans , Pregnancy , Young Adult , Imaging, Three-Dimensional , Mitral Valve/embryology , Mitral Valve , Tricuspid Valve/embryology , Tricuspid Valve , Ultrasonography, Prenatal , Cross-Sectional Studies , Reference Values
SELECTION OF CITATIONS
SEARCH DETAIL