Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 45
Filter
1.
Chinese Journal of Radiation Oncology ; (6): 55-58, 2022.
Article in Chinese | WPRIM | ID: wpr-932628

ABSTRACT

Objective:To investigate the safety and dose of 4D template (real-time adjustable angle template) in the treatment of advanced malignant tumors with 125I seeds. Methods:98 patients with advanced malignant tumors admitted to Department of Thoracic Surgery of Shaanxi Provincial Tumor Hospital were treated with 4D template-navigated radioactive 125I seed implantation from June 2018 to December 2019. Preoperative TPS plan, intraoperative optimization, postoperative verification of immediate dose and postoperative evaluation of implantation dose were performed. The treatment results were observed. Results:All 98 patients completed the seed implantation. The implantation dose of GTV of implantation site receiving external irradiation was (12 489±414) cGy and the dose of no external irradiation was (15 036±514) cGy. V 100% was 84.7%-94.1%, and 88.2%-93.7%. The implantation dose of CTV was (7 450±621) cGy, and (9 080±761) cGy. The quality of dose implantation was evaluated as: excellent in 89 cases (91%, 89/98), good in 7 cases (7%, 7/98), fair in 2 cases (2%, 2/98), and poor in 0 case, respectively. The symptom relief rate of patients with pain was 92%(36/39). The 1-and 2-year local control rates were 61%, 36% and 82%, 54% in patients treated with and without external irradiation, respectively. The difference was statistically significant ( P=0.02). The incidence rates of pneumothorax and hemoptysis were 19%(9/48) and 10%(5/48). No corresponding complications were observed in other parts of the patients. Conclusion:4D template-assisted 125I seed therapy is safe and effective for malignant tumors, and intraoperative adjustment of needle angle and dose optimization can realize the precise control of implantation dose.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 836-842, 2021.
Article in Chinese | WPRIM | ID: wpr-910403

ABSTRACT

Objective:To investigate the technical method and clinical efficacy of CT-guided radioactive 125I seed implantation (RISI) assisted by 3D-printed coplanar template(3D-PCT) in the treatment of metastatic tumors of chest wall, and analyze the influence of dosimetric parameters on the treatment efficacy. Methods:A retrospective analysis was conducted for 55 patients with metastatic tumors of chest wall treated with 3D-PCT-assisted 125I radioactive seed implantation in Tengzhou Central People′s Hospital from January 2014 to March 2021.Preoperative plans were made using a brachytherapy treatment planning system, and dosimetric parameters were assessed at 3d after surgery. During regular CT reexaminations after surgery, the local control rate and overall survival (OS) rate were calculated and the pain relief degree and complications were assessed. The Logrank test and Cox regression were used for univariate and multivariate analyses of local control time (LCT). Meanwhile, receiver operating characteristic (ROC) curves were plotted to analyze the critical values of dosimetric parameters and to predict the LCT. Results:The 1-, 2-, and 3-year OS rates ofthe 55 patients were 72.7% (40/55), 21.8% (12/55), and 16.4% (9/55), respectively.The local control rates of 3, 6, 12, and 24 months were 96.4%(53/55), 86.5%(45/52), 85.0%(34/40), and 91.7%(11/12), respectively. There was no statistically significant difference between postoperative and postoperative dosimetric parameters of GTV, particle number, D90, D100, V100, V150, V200, CI, EI, and HI ( P> 0.05). Compared with postoperative V90, the postoperative V90 decreased with a statistically significant difference( P=0.006). As indicated by the univariate Cox regression analysis, the pathological grade, D90, D100, V90, and V200had significant effects on the LCT( P<0.05). Among them, the pathological grade and D90 were independent influencing factors of the LCT, while the other factors showed no statistically significant difference according to the multivariate Cox regression analysis.The LCT of patients with D90≥127 Gy was significantly longer than that of patients with D90<127 Gy (χ 2=16.61, P=0.000). The pain relief rate was 80.8%(21/26) after three months. Five cases suffered from grade Ⅰ-Ⅱ radioactive dermatitis and one case experienced grade Ⅲ radioactive dermatitis. Conclusions:The 3D-PCT-assisted CT-guided 125I radioactive seed implementation can achieve precise and controllable dose and definite efficacy in the treatment of metastatic tumors of chest wall, with few complications.The LCT was remarkably prolonged in the case of D90≥127 Gy, and D90 is an independent influencing factor of the LCT.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 735-740, 2021.
Article in Chinese | WPRIM | ID: wpr-910386

ABSTRACT

Objective:To compare and analyze the differences of common dose indicators before and after operation of 3D-printing template assisted by CT-guided 125I seed implantation in the treatment of bone metastases to guide clinical application. Methods:A retrospective analysis of 12 lesions in the 10 patients (9 males and 1 female, median age 65 years), who underwent seed implantation surgery for bone metastases in the Tianjin Third Central Hospital from June 2019 to January 2021, was conducted. All the lesions were adopted for 3D-printing template to guide seed implantation and the prescribed dose was 120-140 Gy. The differences of common dose indicators between preoperative treatment plan and postoperative verification plan were compared, including D90 (dose received by 90% of the target volume), D100 (dose received by 100% of the target volume), V90 (the volume percent for tumor target volume receiving 90% of the prescribed dose), V100 (the volume percent for tumor target volume receiving 100% of the prescribed dose), V150 (the volume percent for tumor target volume receiving 150 % of the prescribed dose), as well as the quantity of seeds planned and actually used. The paired t-test was performed to compare and analyze those parameters. Results:There was no statistically significant difference in pre- and postoperative D90, D100, V90, V100, V150 ( P > 0.05). The actual quantity of seeds used after operation was more than that of the preoperative planned quantity and the difference was statistically significant ( t=-2.930, P < 0.05). Conclusions:The clinical use of 3D-printing template assisted by CT-guided 125I seed implantation for bone metastasis should be promoted since the dose is accurate and the requirements of preoperative plan can be achieved.

4.
J Cancer Res Ther ; 2020 Jan; 15(6): 1611-1616
Article | IMSEAR | ID: sea-213579

ABSTRACT

Aim: This study aimed to investigate the technical procedure, safety, and clinical value of the transosseous approach for computed tomography (CT)-guided radioactive 125-iodine (125I) seed implantation for the treatment of thoracic and abdominal lymph node metastases. Subjects and Methods: This was a retrospective study that Nine lymph node metastases in nine patients were treated in our hospital between January 2010 and August 2018. Under CT guidance, at least one puncture path was made through the transosseous approach. The seeds were planted according to the TPS. CT/MRI scans were performed every 2 months after the treatment to evaluate local therapeutic efficacy according to the Response Evaluation Criteria in Solid Tumors. Results: The transosseous approach was successfully established in all patients. The median follow-up time was 11 months (6–36 months). At 2, 4, 6, 8, 10 and 12 months after operation, the objective effective rate and clinical benefit rate were 66.67%, 77.78%, 77.78%, 71.43%, 66.67% and 50.00%; and 88.89%, 88.89%, 88.89%, 71.43%, 66.67% and 50.00%, respectively. The survival rate of the patients at 6, 12, 18, 24, 30 and 36 months after operation was 53.00%, 26.00%, 26.00%, 13.00%, 13.00% and 13.00%, respectively. Conclusions: The transosseous approach for CT-guided radioactive 125I seed implantation was safe, effective, and minimally invasive for the treatment of thoracic and abdominal lymph node metastases

5.
Chinese Journal of Lung Cancer ; (12): 419-423, 2020.
Article in Chinese | WPRIM | ID: wpr-826961

ABSTRACT

BACKGROUND@#Microwave ablation and radioactive seed implantation are therapeutic options for patients with advanced lung cancer and lung metastases lesion who are not surgical candidates. However, reports on therapeutic effectiveness and safety of the two combination treatments methods have been limited to small case series. This research was to assess the clinical outcome and safety of radioactive seed implantation combined with computed tomography (CT)-guided microwave ablation for the treatment of advanced lung cancer and lung metastases lesion.@*METHODS@#The clinical data of 21 advanced lung cancer and lung metastases patients who received treatment at author hospital during the period from May 2018 to December 2018 were retrospectively analyzed. The patients were divided into two groups by whether received extra percutaneous microwave thermal ablation therapy. The short-term effectiveness and safety were analyzed.@*RESULTS@#The efficacy of control group was 28.75%, and the efficacy of experiment group was 14.28%. The rate of adverse reaction between two groups has no significantly difference (P>0.05).@*CONCLUSIONS@#Seed implantation combined with CT-guided microwave ablation for advanced lung cancer and lung metastases is safety and effective.

6.
Chinese Journal of Radiation Oncology ; (6): 122-125, 2020.
Article in Chinese | WPRIM | ID: wpr-868562

ABSTRACT

Objective To compare the preoperative and postoperative dosimetric parameters in the treatment of spinal metastasis,and to verify the accuracy of 3D-printing non-coplanar template (3D-PNCT)combined with CT-guided 125I seed implantation for the treatment of spinal metastasis.Methods The treatment plans of 7 patients with spinal metastasis (9 lesions) from 2016 to 2018 receiving 3D-PNCT in combination with CT-guided 125I seed implantation were retrospectively analyzed.The dosimetric parameters including homogeneity index (HI),conformal index (CI),external index (EI),dose of 90% target volume (Dg0),mPD,volume percent of 100%,150%,and 200% prescribed dose V100、V150、V200 and D2cm3 of spinal cord were compared before and after operation.The british columbia cancer ageny particle implantation quality evaluation standard was applied to evaluate the quality of implantation.Results The HI,EI and CI,Dg0,mPD,V100,V150,V200 and D2cm3 of spinal cord did not significantly differ before and after the plan (all P>0.05).Five were evaluated as excellent and 4 were assessed as good.Conclusion The postoperative dosimetric parameters of 3D-PNCT combined with CT guided 125I seed implantation of spinal metastasis are basically consistent with preoperative dosimetric parameters.The postoperative plans are evaluated as excellent or good,suggesting that the technology has a good therapeutic accuracy in the treatment of spinal metastasis.

7.
Chinese Journal of Radiation Oncology ; (6): 43-46, 2020.
Article in Chinese | WPRIM | ID: wpr-868546

ABSTRACT

Objective To compare the dosimetric data between preoperative plans and postoperative verification in computed tomography (CT)-guided and 3D-printing non-coplanar template-assisted 125I seed implantation for head and neck tumor,aiming to explore the safety,feasibility and accuracy of the individualized template design method.Methods A total of 42 patients with recurrent/metastatic malignant head and neck tumor admitted to Peking University Third Hospital from January to December 2016 were recruited in this study.A prescribed dose of l10-160Gy was adopted.3D-printing non-coplanar templates were designed for 42 cases.The dosimetric parameters including D90,minimum peripheral dose (mPD),V100,V150,V200,conformal index (CI),external index (EI) and homogeneity index (HI) were statistically compared before and after surgery.Results All templates were properly implanted intraoperatively.Compared with preoperative planning,postoperative D90,V100,CI,EI and HI did not significantly differ (P=0.490,0.407,0.893,0.143 and 0.079),whereas mPD,V150 and V200 significantly differed (P=0.036,0.007 and 0.000).Conclusion After postoperative verification,the main dosimetric parameters have high therapeutic accuracy and properly match with preoperative planning,which can meet clinical requirements.

8.
Chinese Journal of Radiation Oncology ; (6): 122-125, 2020.
Article in Chinese | WPRIM | ID: wpr-799443

ABSTRACT

Objective@#To compare the preoperative and postoperative dosimetric parameters in the treatment of spinal metastasis, and to verify the accuracy of 3D-printing non-coplanar template (3D-PNCT) combined with CT-guided 125I seed implantation for the treatment of spinal metastasis.@*Methods@#The treatment plans of 7 patients with spinal metastasis (9 lesions) from 2016 to 2018 receiving 3D-PNCT in combination with CT-guided 125I seed implantation were retrospectively analyzed. The dosimetric parameters including homogeneity index (HI), conformal index (CI), external index (EI), dose of 90% target volume(D90), mPD, volume percent of 100%, 150%, and 200% prescribed dose V100、V150、V200 and D2cm3 of spinal cord were compared before and after operation. The british columbia cancer ageny particle implantation quality evaluation standard was applied to evaluate the quality of implantation.@*Results@#The HI, EI and CI, D90, mPD, V100, V150, V200 and D2cm3 of spinal cord did not significantly differ before and after the plan (all P>0.05). Five were evaluated as excellent and 4 were assessed as good.@*Conclusion@#The postoperative dosimetric parameters of 3D-PNCT combined with CT guided 125I seed implantation of spinal metastasis are basically consistent with preoperative dosimetric parameters. The postoperative plans are evaluated as excellent or good, suggesting that the technology has a good therapeutic accuracy in the treatment of spinal metastasis.

9.
Chinese Journal of Radiation Oncology ; (6): 43-46, 2020.
Article in Chinese | WPRIM | ID: wpr-798805

ABSTRACT

Objective@#To compare the dosimetric data between preoperative plans and postoperative verification in computed tomography (CT)-guided and 3D-printing non-coplanar template-assisted 125I seed implantation for head and neck tumor, aiming to explore the safety, feasibility and accuracy of the individualized template design method.@*Methods@#A total of 42 patients with recurrent/metastatic malignant head and neck tumor admitted to Peking University Third Hospital from January to December 2016 were recruited in this study. A prescribed dose of 110-160Gy was adopted.3D-printing non-coplanar templates were designed for 42 cases. The dosimetric parameters including D90, minimum peripheral dose (mPD), V100, V150, V200, conformal index (CI), external index (EI) and homogeneity index (HI) were statistically compared before and after surgery.@*Results@#All templates were properly implanted intraoperatively. Compared with preoperative planning, postoperative D90, V100, CI, EI and HI did not significantly differ (P=0.490, 0.407, 0.893, 0.143 and 0.079), whereas mPD, V150 and V200 significantly differed (P=0.036, 0.007 and 0.000).@*Conclusion@#After postoperative verification, the main dosimetric parameters have high therapeutic accuracy and properly match with preoperative planning, which can meet clinical requirements.

10.
Chinese Journal of Interventional Imaging and Therapy ; (12): 590-594, 2019.
Article in Chinese | WPRIM | ID: wpr-862067

ABSTRACT

Objective: To explore the application value of 3D-printing non-coplanar template (3D-PNCT) assisted CT-guided 125I seed implantation through dosimetry analysis. Methods: A total of 15 patients underwent 3D-PNCT assisted CT-guided 125I seed implantation. Posture fixation and set-up were performed with CT-simulator devices. Before operation, pre-plan was carried out, and 3D-PNCT was printed. 125I seeds were implanted into the lesions according to pre-plan after set-up and following postoperative verification. The dosimetric parameters, including doses of pre-plan and post-operation 90%, 100% target volume (D90, D100) and volume percent of 90%, 100%, 150% prescribed doses (V90, V100, V150) were compared. Results: 3D-PNCT assisted CT-guided 125I seed implantation were successfully accomplished in 18 lesions of all 15 patients. The median time of 3D-PNCT set-up was (11.62±2.57)min. Post-operation gross tumor volume (GTV) was more than that in pre-plan ([64.25±50.16]cm3 vs [57.37±44.25]cm3; t=-3.163, P=0.006). The number of implantated seeds were more than that in pre-plan (46.39±24.18 vs 43.78±21.63; t=-2.636, P=0.017). Post-operation V100 and V150 were less than those in pre-plan (both P0.05). Conclusion: 3D-PNCT set-up can be quickly and precisely accomplished using CT-simulator devices. 3D-PNCT assisted CT-guided 125I seed implantation can accurately performed through well match of post-operation main dosimetric parameters with those in pre-plan.

11.
Chinese Journal of Practical Nursing ; (36): 1269-1272, 2019.
Article in Chinese | WPRIM | ID: wpr-802841

ABSTRACT

Objective@#To explore the nursing countermeasures of children with facial rhabdomyosarcoma treated by radioactive seed implantation.@*Methods@#Retrospective analysis was performed on the diagnosis, treatment and nursing process of a child orbital embryonal rhabdomyosarcoma admitted to the department of tumor radiotherapy, Peking University Third Hospital in February 2018.@*Results@#Mild wound swelling and pain occurred after treatment, and no acute complications such as increased intracranial pressure, particle displacement, wound bleeding and infection, or visual acuity change occurred.@*Conclusions@#Disease evaluation and preoperative preparation should be done strictly before the implantation of radioactive particles; changes of the disease should be monitored strictly during the operation to ensure the safety of treatment posture; postoperative complications observation and radiation protection guidance are the basis to ensure the smooth completion of the stage treatment of children.

12.
Chinese Journal of Practical Nursing ; (36): 1269-1272, 2019.
Article in Chinese | WPRIM | ID: wpr-752625

ABSTRACT

Objective To explore the nursing countermeasures of children with facial rhabdomyosarcoma treated by radioactive seed implantation. Methods Retrospective analysis was performed on the diagnosis, treatment and nursing process of a child orbital embryonal rhabdomyosarcoma admitted to the department of tumor radiotherapy, Peking University Third Hospital in February 2018. Results Mild wound swelling and pain occurred after treatment, and no acute complications such as increased intracranial pressure, particle displacement, wound bleeding and infection, or visual acuity change occurred. Conclusions Disease evaluation and preoperative preparation should be done strictly before the implantation of radioactive particles; changes of the disease should be monitored strictly during the operation to ensure the safety of treatment posture; postoperative complications observation and radiation protection guidance are the basis to ensure the smooth completion of the stage treatment of children.

13.
Chinese Journal of Radiation Oncology ; (6): 793-797, 2018.
Article in Chinese | WPRIM | ID: wpr-708265

ABSTRACT

Objective To evaluate the clinical efficacy and safety of CT-guided 125 I seed implantation in the treatment of recurrent head and neck tumors after radiotherapy. Methods Clinical data of 101 patients who received CT-guided radioactive 125 I seed implantation for recurrent head and neck cancer after radiotherapy from 2007 to 2015 were retrospectively analyzed. The median accumulated dose of external radiotherapy was 66 Gy and the median dose after seed implantation (D90) was 117 Gy. The local progression-free survival and overall survival were analyzed by Kaplan-Meier method. Univariate analysis was performed by log-rank test and multivariate analysis was conducted by using Cox regression model. Results The median follow-up time was 12. 2 months. The 5-year local progression-free survival rate was 26. 6%.The 5-year overall survival rate was 15. 5%. Univariate analysis demonstrated that age,pathological type,implantation site,lesion volume,D90 and short-term efficacy were correlated with local control,and KPS score,lesion volume ,D90,and short-term efficacy were associated with survival (all P<0. 05). Multivariate analysis revealed that pathological type,lesion volume ,D90 and short-term efficacy were independent factors related to local control (P= 0. 000, 0. 002,0. 003 and 0. 014).In terms of the adverse events,skin/ mucosal ulceration was observed in 25. 7% and pain occurred in 13. 9% of all patients. No correlation was noted between the adverse events and dose.Conclusions CT-guided radioactive 125 I seed implantation is an efficacious and safe treatment of recurrent head and neck tumors after radiotherapy. Non-squamous carcinoma,small lesion volume and high dose (D90) indicate excellent local control.

14.
Chinese Journal of Radiological Medicine and Protection ; (12): 842-845,858, 2018.
Article in Chinese | WPRIM | ID: wpr-708144

ABSTRACT

Objective To compare the dose distributions of postoperative plans with preoperative plans for 3D printing guide plate assist radioactive seeds implantations, explore the effects of the technology for seeds implantations in dosimetry level. Methods From January 2016 to December 2016, a total of 42 patients of local recurrent malignant tumor of head and neck received 3D printing guide plate assist radioactive seeds implantations in in Peking University Third Hospital, and included in the retrospective study. The prescribed dose was 110 -160 Gy. All patients carried out preoperative planning design, individual guide plate production, and compared the dose distribution of postoperative plan with preoperative plan. Dose parameters include D90 , mPD, V100 , V150 , V200 , CI, EI and HI. Statistical method was paired t-test. Results A total of 423D printing individual templates were produced. The mean GTV volume of all patients was 28. 6 cm3 , and mean D90 of postoperative target area ( GTV) was 142. 6 Gy. For postoperative plans, the mean D90 , mPD, V100 , V150, V200 was 142. 6 Gy, 77. 3 Gy, 92. 48%, 68. 40%and 42. 98%, respectively, and 144. 5 Gy, 70. 2 Gy, 91. 45%, 63. 12% and 34. 74%, respectively, in preoperative plans. Except mPD, V150, V200(t= -2. 166, -2. 863, -4. 778, P<0. 05), there was no significant difference between the two groups. Conclusions 3D printing guide plate could provide good accuracy for positioning and direction. For local recurrent malignant tumor of head and neck, the actual dose distributions in postoperative validations were close to the expectations of preoperative plans which mean the improvement of accuracy in treatment.

15.
Chinese Journal of Radiological Medicine and Protection ; (12): 429-433, 2018.
Article in Chinese | WPRIM | ID: wpr-708082

ABSTRACT

Objective To evaluate the outcomes and prognostic factors of image-guided 125I seed implantation for locally recurrent soft tissue sarcoma(RSTS).Methods A total of 60 patients with RSTS who received image-guided 125I seed implantation in Peking University Third Hospital,from September 2002 to December 2015,were retrospectively analyzed.The enrollment criteria: KPS >60 points,refused or could not tolerate surgery or radiotherapy,the expecting survival time >3 months,relapsed after multiple treatment of soft tissue sarcoma,and underwent CT or ultrasound guided 125 I seed implantation treatment.In all,the median activity of seeds was 25.9×106Bq(range,11.1×106-29.6×106Bq),median number of implanted seeds was 58(range,3-133),and the median D90was 120 Gy(range,36.50-460.97 Gy).The local progression-free survival(LPFS)and overall survival(OS)were calculated using the Kaplan-Meier method.The log-rank test and Cox regression model were used for the univariate and multivariate analyses.Results The median follow-up was 18.75 months(range,1-146).The median OS was 18.5 months(95%CI 13.1-23.9).The 1-,3-and 5-year OS rate were 63.3%,33.0%and 29.5%,respectively.The 1-,3-and 5-year LPFS rate were 72.5%,63.7%and 59.7%,respectively.The general rate of pain relieving was 100%(6/6).8.3%(5/60)presented grade Ⅳskin toxicity.No fatal complications ocurred.The univariate analysis suggested that tumor size,tumor volume,KPS score,D90were prognostic factors of OS and LPFS.The multivariate analysis demonstrated that previous chemotherapy history and distant metastases were independent prognostic factors of survival.Conclusions Image-guided 125I seed implantation for recurrent soft tissue sarcoma is a safe treatment option with high efficacy and low morbidity.Tumor size and D90were the prognostic factors of OS and LPFS.

16.
Chinese Journal of Nursing ; (12): 293-296, 2017.
Article in Chinese | WPRIM | ID: wpr-514313

ABSTRACT

This paper summarized nursing experience of 23 patients with malignant tumor treated by 3D printing individualized template and 125I seed implantation.Nursing points included:preoperative assessment and preparation,reviewing the process of template conduction,assisting the physician to simulate the position of patients,making treatment plans,preparing templates before operation;resetting and maintaining position of patients,performing template alignment,seed implantation,monitoring vital signs and complications during operation;observation of complications,providing radiation protection and discharge guidance after operation.All 23 patients completed 125I seed implantation and no serious complication was observed.All patients recovered well and were discharged after treatment.

17.
Chinese Journal of Radiation Oncology ; (6): 754-758, 2017.
Article in Chinese | WPRIM | ID: wpr-620251

ABSTRACT

Objective To compare the preoperative and postoperative dosimetric results of radioactive seed implantation assisted by 3D printing template in the treatment of chest malignant tumor, and to examine the effect this technique on the precision of radioactive seed implantation.Methods A total of 21 patients who received 3D printing template-assisted CT-guided 125I seed implantation for chest tumors in 2016 were included in the study.The prescribed dose of the treatment was 110-180 Gy.Preoperative planning, individual template production, and puncture and seed implantation were performed in all patients, and the postoperative dosimetric results were then compared with the preoperative plan by assessing various dosimetric parameters including D90, MPD, V100, V150, CI, EI, and HI of gross tumor volume (GTV), D2cc of the spinal cord and aorta, and Dmean and V20 of the affected side of the lung.Statistical analysis was performed using the Wilcoxon non-parametric test.Results A total of 21 3D printing templates were designed and produced.The mean GTV volume (preoperative) of all patients was 77.1 cm3, and the mean number of implanted seeds was 68.In addition, the mean D90 of the postoperative GTV was 147.3 Gy.There were slight changes in the dosimetric parameters after treatment (P>0.05).Conclusions 3D printing template allows for accurate positioning and implantation of radioactive seeds during the treatment of chest tumor.Postoperative dosimetric parameters were consistent with those in the preoperative planning, indicating that the 3D printing template provides high precision for the treatment of chest tumor.

18.
Chinese Journal of Radiological Medicine and Protection ; (12): 485-489, 2017.
Article in Chinese | WPRIM | ID: wpr-618045

ABSTRACT

Objective To compare the dosimetric data between preoperative plans and postoperative verification in computed tomography (CT)-guided and 3D-printing non-coplanar templateassisted 125I seed implantation for pelvic tumor,and to explore the feasibility and accuracy of the personalized template designmethod.Methods A total of 51 patients registered from Dec 2015 to Dec 2016 who were applied with 3D-printing guided template assisted radioactive seed implantations in the hospital were included in this study.A prescribed dose of 110-160 Gy was adopted.3D-printing templates were designed and produced for 51 cases.The dosimetric parameters:Dg0,minimum peripheral dose (mPD),V100,V150,V200,conformal index (CI),external index (EI),and homogeneity index (HI) were compared between pre-and post-plans.Results 51 cases' templates were in place well during the operations.Compared with the preoperative planning,the postoperative D90,V100,V150,V200,CI,EI and HI differences had no statistical difference (P > 0.05);mPD is larger than before (t =-2.96,P < 0.05).Conclusions The main dosimetric parameters of postoperative verification were consistent well with the preoperative planning and have good accuracy,which could meet the clinical requirements.

19.
Chinese Journal of Radiological Medicine and Protection ; (12): 490-494, 2017.
Article in Chinese | WPRIM | ID: wpr-618044

ABSTRACT

Objective To investigate the accuracy of 3D-printing non-coplanar template (3D-PNCT) assisted 125I seed implantation with CT guidance in the pelvic recurrent cervical between the preplan and post-plan dosimetric parameters.Methods Nine patients with pelvic recurrent cervical cancer received 125I seed implantation under CT guidance assisted with 3D-PNCT.A pre-plan based brachytherapy treatment planning system (B-TPS) assisted with 3D-PNCT for seed needle depth,direction and angle was designed.The dosimetry parameters including homogeneity index (HI),dose of 90% target volume (Dg0),mPD,volume percent of 100%,150% and 200% prescribed dose V100,V150 and V200 and organ at risk between the pre-plan and post-plan were compared.Results Total seeds number was 675 (median 44,25-114) according to pre-plan,and 669 (median 47,25-113) seeds were implanted actually.138 needles need implant according to preplan,and 132 needles was implanted actually.The median angle deviation was 1.99 ° ± 2.94°(0 °-13 °).There was no significant difference of HI,EI and CI between perand post-plan.The differences of D90,MPD,V100,V150 and V200 between pre-and post-plan were not significant.Conclusions The confidence of pre-plan and post-plan for 3D-PNCT assisted 125I seed implantation in the pelvic recurrent cervical cancer could be accurately performed under CT guidance.

20.
Chinese Journal of Radiological Medicine and Protection ; (12): 514-517, 2017.
Article in Chinese | WPRIM | ID: wpr-618042

ABSTRACT

Objective To compare the dose distribution of postoperative plans with preoperative plans for 3D printing coplanar template assisted radioactive seed implantation,and to explore the accuracy of the technique in seed implantation.Methods From November 2015 to December 2016 a total of 32 patients were selected and underwent 3D printing coplanar template assisted radioactive seed implantation in Tengzhou Central People's Hospital of Shandong province.There were 36 implanted lesions,including l0 in the lungs,5 in neck lymphs,3 in pelvic cavities,3 in vertebral body,2 in pancreas,2 in abdominal lymph nodes,2 in portal veins,and 9 in the other parts.All patients were given preoperative planning and guided by the coplanar templates.Compared with the preoperative plan,all levels needles inserted at the same time.According to preoperative planning the implantation surgery was completed accurately.The postoperative dosimetry was evaluated.The preoperative and postoperative dosimetry parameters were compared,including Dg0,D100,V90,V100.V150,V200 and conformal index (CI),external index (EI),and homogeneity index(HI).The paired t test was used to perform the statistical analysis.Result There was no significant differences in Dg0,D100,V90,V100,V150,V200,CI,EI and HI between before and after operation(P > 0.05).Conclusions The dose parameters in postplan showed no difference compared with preplan in this study.For fixed and moving organ tumors,3D printing coplanar template assisted radioactive seed implantation has good therapeutic accuracy,and may be a standardized surgicalmethod for seed implantation in the future.

SELECTION OF CITATIONS
SEARCH DETAIL