Chinese Journal of Radiological Medicine and Protection ; (12): 42-46, 2020.
Article in Chinese | WPRIM | ID: wpr-798777

ABSTRACT

Objective@#To compare the calibration result of standard X-ray RQR radiation field between SSDL (NIRP) and CEA LIST LNHB(France), and to explore the feasibility of calibrating Hp(3) in standard X-ray RQR radiation field of SSDL(NIRP).@*Methods@#Using a column model with a diameter and high of 20 cm, TLD was calibrated in SSDL (NIRP) and CEA LIST LNHB (France) to measure the personal dose equivalent eye lens dose Hp(3), X-ray RQR radiation field included RQR4(60 kV), RQR7(90 kV), RQR9(120 kV), with energy response, angle response and linear response.@*Results@#In terms of energy response, the calibration results of TLD in both SSDL (NIRP) and CEA LIST LNHB (France) were in good agreement. The difference between exposure value and response value was less than 10%. In terms of angle response, the calibration result of TLD in CEA LIST LNHB (France) was better in SSDL(NIRP). The difference between exposure value and response value in CEA LIST LNHB (France) was less than 6%, while the difference between exposure value and response value in SSDL(NIRP) was more than 10% at angle of 20°. In terms of linear response, both calibration result of SSDL (NIRP) and CEA LIST LNHB (France) were in good agreement.@*Conclusions@#The standard X-ray RQR field in SSDL (NIRP) can be used for the calibration of Hp(3).

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 42-46, 2020.
Article in Chinese | WPRIM | ID: wpr-868397

ABSTRACT

Objective To compare the calibration result of standard X-ray RQR radiation field between SSDL (NIRP) and CEA LIST LNHB (France),and to explore the feasibility of calibrating Hp (3) in standard X-ray RQR radiation field of SSDL (NIRP).Methods Using a column model with a diameter and high of 20 cm,TLD was calibrated in SSDL (NIRP) and CEA LIST LNHB (France) to measure the personal dose equivalent eye lens dose Hp (3),X-ray RQR radiation field included RQR4 (60 kV),RQR7 (90 kV),RQR9 (120 kV),with energy response,angle response and linear response.Results In terms of energy response,the calibration results of TLD in both SSDL (NIRP) and CEA LIST LNHB (France) were in good agreement.The difference between exposure value and response value was less than 10%.In terms of angle response,the calibration result of TLD in CEA LIST LNHB (France) was better in SSDL (NIRP).The difference between exposure value and response value in CEA LIST LNHB (France) was less than 6%,while the difference between exposure value and response value in SSDI (NIRP) was more than 10% at angle of 20°.In terms of linear response,both calibration result of SSDL (NIRP) and CEA LIST LNHB (France) were in good agreement.Conclusions The standard X-ray RQR field in SSDL (NIRP) can be used for the calibration of Hp (3).

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 302-306, 2018.
Article in Chinese | WPRIM | ID: wpr-708059

ABSTRACT

Objective To use thermoluminescense dosimeters (TLDs) to evaluate the radiation doses to various critical organs in the computerized imaging reference systems (CIRS) 5 years old pediatric anthropomorphic phantom result ing from Varian kilovohage cone beam CT (kV-CBCT) system based on the standard scanning protocols.Effective dose were also calculated based on dose measurement.Methods A batch of TLDs with consistency no larger than 2% were selected and annealed.First,the doses in an anthropomorphic pelvic phantom were measured using a CT chamber and TLDs,respectively,based on the standard pelvic protocols.The ratio of the both measurements is the TLD conversion coefficient.Other TLDs from the same batch were placed between two tissue-equivalent inserts and placed into the pre-drilled organ cavities of the pediatric phantom.By using standard protocols,the organs dose were measured,based on which the corresponding effective doses were calculated.Results The TLD conversion coefficient was 3.91 mGy/per reading.By using the standard head,low-dose thorax,pelvis protocol,the whole body effective dose was 0.63,6.85 and 19.3 mSv,respectively.Conclusions It is feasible for using the CT chamber-calibrated TLDs to measure the radiation doses from kV-CBCT to pediatric anthropomorphic phantom.The effective dose in pelvic protocol was higher than in thorax and head protocol,indicating that the pelvic protocol has a penitential to lead to larger radiation damage and higher risk of secondary cancer.

4.
China Medical Equipment ; (12): 10-12,13, 2016.
Article in Chinese | WPRIM | ID: wpr-603931

ABSTRACT

Objective:According to the technical standard of ISO and current regulations in China, the X/γ standard calibration quality for the finger-ring dosimeter irradiation was established in Beijing SSDL, it can ensure the traceability of surveillance data within countrywide.Methods: Air kerma-rate was determined in the X-ray beams,137Cs and60Co by a standard dosimeter, combined transfer coefficientHp(0.07) provided by standards, and confirmed condition of X/γ standard calibration quality for the finger-ring dosimeter irradiation. Using finger-ring TLD dosimeter verified the radiation beam qualities Hp on the ISO finger-phantom.Results: The linearity and energy response of the TLD dosimeter met ISO and national standard in Beijing SSDL.Conclusion: The X/γ standard radiation field can be used for the calibration of finger-ring dosimeter standard curves and experiment of research, and can further promote the comparability and reliability of the surveillance data.

5.
Chinese Journal of Radiological Medicine and Protection ; (12): 303-307, 2016.
Article in Chinese | WPRIM | ID: wpr-488576

ABSTRACT

Objective To establish methods of measuring the eye lens dose to interventional staff,to obtain relevant dose data and to provide a scientific basis for reducing eye lens dose.Methods Two kinds of dosimeters,thermoluminescent dosimeter (TLD) and optically stimulated luminescence dosimeter (OSLD),were selected to measure the personal dose equivalent HP (3) to eye lens of occupational staff in several kinds of interventional procedures,including cardiovascular interventional procedures,cerebrovascular interventional procedures etc.Five types of Digital Subtraction Angiography (DSA) equipment were chosen in the study,including single tube equipment and double tube equipment.Results The eye lens dose HP (3) to interventional staff varied significantly with different interventional procedures.The lowest dose is shown in the coronary angiography procedure,while the highest dose shown in the cerebral stenting procedure.For the same type of interventional procedure,the eye lens dose to the primary interventionist was the highest.For same interventionist,the dose to the left eye was obviously higher than that to the right eye.In addition,the measured results of OSLD were apparently higher than that of TLD.Conclusions Both TLD and OSLD could be used to measure eye lens dose,and the ways of calibrating TLD to evaluate personal dose equivalent HP (3) were feasible.The reason of significant difference between the measured results of TLD and OSLD needs further research.

6.
Chinese Journal of Radiological Medicine and Protection ; (12): 929-934, 2016.
Article in Chinese | WPRIM | ID: wpr-505429

ABSTRACT

Objective To establish the methods for measuring the dose to occupational staff's eye lens in interventional procedures with direct-reading dosimeters,and to realize the real-time monitoring of eye lens dose and warning for high dose rate,thus providing the scientific basis of the staff radiological protection in interventional procedures.Methods Direct-reading dosimeters were calibrated with personal dose equivalent HP (3).The eye lens doses for occupational staff in different kinds of interventional procedures were measured by the devices with both single-and double X-ray tubes.The data obtained fromthe direct-reading dosimeters was compared to those obtained from TLDs.Results Direct-reading dosimeters showed good linear fitting with the calibration of HP (3),and the coefficients of variation were lower than 5%.The average eye lens HP (3) for the main operator in coronary arteriography and stent implantation in brain obtained by direct-reading dosimeters were 12.0 and 24.5 μSv,respectively,whereas those obtained by TLDs were 11.9 and 22.7 μSv,respectively.The direct-reading dosimeters gave similar t~nds as TLDs do so.The direct-reading dosimeters were able to provide eye lens HP (3) in each individual interventional procedure,and to monitor the real-time dose rate as well.Conclusions The calibration of HP (3) and the data gained by direct-reading dosimeters are reliable.Therefore,the methods for real-time measurement of eye lens dose for occupational staff in interventional procedures are successfully established.

7.
Malaysian Journal of Health Sciences ; : 39-49, 2015.
Article in English | WPRIM | ID: wpr-626585

ABSTRACT

The fi rst part of this study was about measurement of dosimetric parameters for small photon beams to be used as input data for treatment planning computer system (TPS) and to verify the dose calculated by TPS in Stereotactic Radiosurgery (SRS) procedure. The beam data required were percentage depth dose (PDD), off-axis ratio (OAR) and scattering factor. Small beams of 5 mm to 45 mm diameter from a circular cone collimator in SRS were used for beam data measurements. Measurements were made using pinpoint ionisation chamber (0.016cc). In the second part of this study, we reported the important of carrying out quality assurance (QA) procedures before SRS treatment which were found to infl uence the accuracy of dose delivery. These QA procedures consisted of measurements on the accuracy in target localization and treatment room laser alignment. The calculated TPS dose for treatment was verifi ed using pinpoint ionisation chamber and thermoluminescent detector (TLD) 100H. The deviation mean between measured and calculated dose was -3.28%. The measured dose obtained from pinpoint ionisation chamber is in good agreement with the calculated dose from TPS with deviation mean of 2.17%. In conclusion, pinpoint ionisation chamber gives a better accuracy in dose calculation compared to TLD 100H. The results are acceptable as recommended by International Commission on Radiation Units and Measurements (ICRU) Report No. 50 (1994) that dose delivered to the target volume must be within ± 5% error.


Subject(s)
Radiosurgery
8.
Chinese Journal of Radiological Medicine and Protection ; (12): 114-118, 2015.
Article in Chinese | WPRIM | ID: wpr-466249

ABSTRACT

Objective To measure and calculate the dose distribution (tissue absorbed dose) of mouth floor area while using 125I to treat sublingual gland carcinoma.Methods Phantom of head and neck was used to place the 125I radioactive seeds to simulate the sublingual gland carcinoma treatment.125I radioactive seeds of 29.6 and 25.9 MBq per seed were used as two groups,with 31 seeds in each group,and prescribed dose (peripheral matched dose) was 120 Gy.Thermoluminescence dosimetry (TLD) was used to measure the absorbed dose value in the simulated target and adjacent area.Gafchromic Eriochrome Black T (EBT) film was used to draw the dose distribution curve.Results Dose absorbed in the target area,target area center and the adjacent area one centimeter away from target reached 160 Gy,390-500 Gy,and 90-170 Gy,respectively.Dose of the skin ranged from 25 to 81 Gy,dose of mandible ranged from 7.9 to 67 Gy.No radiation cold spot was found.Conclusions 125I seeds could achieve an effective therapeutic dose distribution of the target area for sublingual gland carcinoma.Dose absorbed in the adjacent tissue is under safety limit.The radiation dose at mandible is lower,reducing the possibility of radiation damage to the bone.

9.
Chinese Journal of Radiological Medicine and Protection ; (12): 456-460, 2014.
Article in Chinese | WPRIM | ID: wpr-453538

ABSTRACT

Objective To verify the reliability of dose parameters of radiotherapy under reference and non-reference conditions by using TLD.Methods Dose parameters were verified by using TLDs under reference and non-reference conditions,including the maximum dose in axel of 5 electron beams with energy of 9 MeV and the variations of dose by depth,source-skin distance,exposure field and 45° wedge for 10 photon beams with energy of 6 MV in 5 hospitals.Results The average relative deviation of 6 MV photon beam measured between TLDs and finger ionization chambers were 4.45%,within ± 7% as required by IAEA.The average relative deviation of 9 MeV electron beam measured between TLDs and plane parallel chambers were 2.45%,within ± 5% was required by IAEA.Conclusions Measuring dosimetric parameters by using TLDs under reference and non-reference conditions was reliable and feasible.

10.
Chinese Journal of Radiological Medicine and Protection ; (12): 441-445, 2014.
Article in Chinese | WPRIM | ID: wpr-453535

ABSTRACT

Objective To develop a methodology for auditing dosimetric parameters using TLD for photon and electron beams in non-reference conditions.Methods The correction experiments have been developed for non-linear dose response,PAAM holder,energy,fading and dispersion using TLD for 60Co γ-ray,high energy X-ray and electron beams.The measuring method was set up for absorbed dose estimation by TLDs in water.3 photon beams and 2 electron beams were selected for research purposes,and 5 photon beams and 4 electron beams for reliability research.Results The research results were evaluated for60Co source,6,10,15 and 18 MV photon beams in non-reference conditions at off-axis,with the relative deviation within-0.1%-7.2% at-off axis (IAEA's acceptable deviation:± 7.0%).The verification results were evaluated for 5 photon beams in non-reference conditions at on-axis,with the relative deviation are within 0.1%-7.0%.The verification results were evaluated for 4 electron beams in non-reference conditions,with the relative deviation within 0-4.7% (IAEA's acceptable deviation:±5.0%).Conclusions It is convenient and accurate to use TLD method for quality audits for clinic dosimetry parameters in radiotherapy.Two kinds of IAEA TLD holders are feasible for use in TLD audits.Absorbed doses for high energy electron beam were corrected using plane parallel chambers and verified using TLD,with good results obtained.

11.
Chinese Journal of Radiological Medicine and Protection ; (12): 446-450, 2014.
Article in Chinese | WPRIM | ID: wpr-453523

ABSTRACT

Objective To verify the reliability of radiotherapy dosimetric parameters in reference and non-reference conditions using thermoluminescent dosimeters (TLDs).Methods Using the established TLD method,the dose variations with different radiation field sizes and 45 ° wedge plate were verified for 10 photon beams of 6 MV,together with dosimetric parameters at the point of maximum axial dose for 4 electron beams of 9 MeV under reference and non-reference conditions.Comparisons were made between TLD results and finger ionization chamber results.Results The average relative deviation,for 6 MV photon beams,between TLD results and finger ionization chamber measurements was 4.7%,within ± 7% as required by the IAEA.The average relative deviation,for 9 MeV electron beam,between TLD results and plane parallel ionization chamber measurements was 2.4 %,not beyond ± 5% permitted by IAEA.Conclusions Using TLD method to verify the radiotherapy dosimetric parameters in reference and non-reference conditions was reliable,simple and feasible.

12.
Malaysian Journal of Health Sciences ; : 37-42, 2012.
Article in English | WPRIM | ID: wpr-626378

ABSTRACT

Thyroid and gonads are radiosensitive organs which requires radiation shield to reduce the dose received. However, radiation shielding is not widely used in radionuclide imaging because it is heavy, uncomfortable and can cause pain in the spine. Therefore, a research was carried out to determine the ability of thyroid and gonad radiation shield which is thinner and lighter in reducing radiation dose. A study was conducted in Hospital Putrajaya to determine the radiation dose received by the thyroid and gonads during a complete Positron Emission Tomography-Computed Tomography (PET-CT) procedure with and without radiation shield. A total of six male staffs have been chosen as subject and data from 33 complete PET-CT procedures have been collected. For every PET-CT procedure, the subject’s thyroid and gonad were shielded using 0.5-mm thick radiation shielded, model Mavig 615 (USA) and Shielding International (USA) respectively. Thermal luminescent dosimeter (TLD) chips were used as radiation dose detector. The average 18FFDG radioactivity administered to the patient was 387 MBq and the average scan time is 9.224 ± 1.797 minutes. The results showed that the mean equivalent dose received by the thyroid with and without shielding were 0.080 ± 0.033 mSv and 0.078 ± 0.039 mSv respectively. The mean equivalent dose received by gonad with and without shielding were 0.059 ± 0.040 mSv and 0.061 ± 0.030 mSv respectively. Radiation shield with 0.5 mm thickness is unable to reduce radiation dose received by the thyroid (p = 0.76) and gonads (p = 0.79) because it is too thin to resist the high-energy radiation during PET-CT procedures. Thyroid receive higher radiation dose of 0.016 m Sv compared to the gonads (p < 0.05) because the thyroid’s position is more exposed to radiation sources which are 18F-FDG during radiopharmaceutical preparation and patients after administered with 18F-FDG during PET-CT procedure.

13.
Chinese Journal of Radiological Medicine and Protection ; (12): 398-403, 2011.
Article in Chinese | WPRIM | ID: wpr-424134

ABSTRACT

Objective To explore the method for measuring and calculating both absorbed dose and effective dose received in organ and tissues of occupational workers by using TLDs for the implantation of 125Ⅰ seed sources.Methods The experiments with 60Co γ-rays were carried out for the stability.A group of TLD chips was exposed to 125Ⅰ seed sources to establish standard dose curve for air kerma.During the 125Ⅰ seed implantation, the TLD chips were pasted to 13 locations like thyroid inside and outside the lead aprons worn by occupational workers to measure average absorbed dose and calculate the absorbed doses and effectives to organs and tissues.Results For 3 cases of prostate cancers with implantation of 125Ⅰ seeds, the worker's organs and tissues received the absorbed dose 0.02 -3.80 μ Gy and effective dose 0.06- 1.81 μSv outside lead aprons and the highest absorbed dose 2.35 μ Gy and effective 0.02 μSv inside lead aprons, respectively, with more than 65.9% of rays shielded.For 3 cases of brain cancers with implantation of 125Ⅰ seeds, the workers received the absorbed dose 0.23 - 11.31 μGy and effective dose 0.88 - 4.07 μSv outside lead aprons and the highest absorbed dose 2.22 μ Gy and effective dose 0.09 μSv inside lead aprons, respectively, with more than 54.5% of rays shielded.For 3 cases of lung cancers with implantation of 125Ⅰ seeds, the workers received the absorbed dose 0.03 - 14.78 μGy and effective dose 0.35 -7.59 μSv outside lead aprons and the highest absorbed dose 4.09 μGy and effective 0.22 μSv inside lead aprons, respectively, with more than 58.4% of rays shielded.For 2 cases of mediastinum cancers with implantation of 125Ⅰseeds, the workers received the absorbed dose 0.06 - 74.91 μGy and effective dose 0.83 - 17.96 μSv outside lead aprons and the highest absorbed dose 10.29 μGy and effective 0.5 μSv inside lead aprons, respectively, with more than 85% of rays shielded.For one case of ovary cancer with implantation of 125Ⅰ seeds, the worker received the absorbed dose 0.09 - 14.29 μGy and effective dose 2.40 - 4.50 μSv outside lead aprons and the highest absorbed dose 7.77 μGy and effective 0.12 μSv inside lead aprons, respectively, with more than 34% of rays shielded.For one case of eye cancer with implantation of 125Ⅰ seeds, the workers received the absorbed dose 2.2 -39.84 μGy and effective dose 4.48 - 10.06 μSv outside aprons and the highest absorbed dose 5.19 μGy and effective 0.16 μSv inside aprons, respectively, with more than 54.6 % of rays shielded.Conclusions The method of using TLDs to measure the doses to the occupational workers in the course of the implantation of 125Ⅰ seed sources is simple and easy to operate.It would be an effective approach to protecting medical workers in the case of brachytherapy.

14.
Korean Journal of Medical Physics ; : 92-98, 2011.
Article in Korean | WPRIM | ID: wpr-76144

ABSTRACT

This study is to keep the accuracy and stability of the output dose evaluations for linear accelerator photon beams by using the air ionization chambers (TM31010, 0.125 cc, PTW) through the Task Group 51 protocol. The absorbed dose to water calibration factor NdwCo-60 was delivered from the air kerma calibration factor Nk which was provided from manufacture through SSDL calibration for determination of output factor. The ionization chamber of TM31010 series was reviewed the calibration factor and other parameters for reduce the uncertainty within +/-2% discrepancy and we found the supplied NdwCo-60 which was derived from Nk has shown a -2.8% uncertainty compare to that of PSDL. The authors provided the program to perform the output dosimetry with TG-51 protocol as it is composed same screen of TG-51 worksheets. The evaluated dose by determination of output factor delivered to postal TLD block for comparison the output dose to that of MDACC (RPC) in postal monitoring program. The results have shown the 1.001+/-0.013 for 6 MV and 0.997+/-0.012 discrepancy for 15 MV X rays for 5 years followed. This study shows the evaluated outputs for linear accelerate photon beams are very close to that of international output monitor with small discrepancy of +/-1.3% with high reliability and showing the gradually stability after 2010.


Subject(s)
Air Ionization , Calibration , Organothiophosphorus Compounds , Particle Accelerators , Phenylpropionates , Uncertainty , Water
15.
Radiol. bras ; 43(2): 119-123, mar.-abr. 2010. graf, tab
Article in English, Portuguese | LILACS | ID: lil-551820

ABSTRACT

OBJETIVO: Determinar, por simulação Monte Carlo, os espectros de feixes de cobaltoterapia em profundidade na água e fatores de correção para doses absorvidas em dosímetros termoluminescentes de fluoreto de lítio. MATERIAIS E MÉTODOS: As simulações dos espectros secundários da fonte clínica de cobalto-60 foram realizadas com o código Monte Carlo PENELOPE, em diversas profundidades na água. Medidas experimentais de dose profunda foram obtidas com dosímetros termoluminescentes e câmara de ionização em condições de referência em radioterapia. Os fatores de correção para os dosímetros termoluminescentes foram obtidos através da razão entre as absorções relativas ao espectro de baixa energia e ao espectro total. RESULTADOS: A análise espectral em profundidade revelou a existência de espectros secundários de baixa energia responsáveis por uma parcela significativa da deposição de dose. Foram observadas discrepâncias de 3,2 por cento nas doses medidas experimentalmente com a câmara de ionização e com os dosímetros termoluminescentes. O uso dos fatores de correção nessas medidas permitiu diminuir a discrepância entre as doses absorvidas para, no máximo, 0,3 por cento. CONCLUSÃO: Os espectros simulados permitem o cálculo de fatores de correção para as leituras de dosímetros termoluminescentes utilizados em medidas de dose profunda, contribuindo para a redução das incertezas associadas ao controle de qualidade de feixes clínicos em radioterapia.


OBJECTIVE: To calculate spectra of cobalt-60 beam at water depth and correction factors for absorbed dose measurements obtained with lithium fluoride thermoluminescent dosimeters using Monte Carlo simulation. MATERIALS AND METHODS: The simulations of secondary spectra of clinical cobalt-60 sources were performed with the PENELOPE Monte Carlo code at different water depths. Experimental measurements of deep doses were obtained with thermoluminescent dosimeters and ionization chamber under reference conditions for radiotherapy. Correction factors for the thermoluminescent dosimeters detectors were obtained through the ratio between the relative energy absorption for the low energy spectrum and the total spectrum. RESULTS: Deep spectral analysis has demonstrated the presence of secondary low-energy spectra responsible for a significant portion of the dose deposition. Discrepancies of 3.2 percent were observed among the doses measured with ionization chamber and thermoluminescent dosimeters. The adoption of correction factors has allowed a reduction in the discrepancy among absorbed doses to a maximum of 0.3 percent. CONCLUSION: Simulated spectra allow the calculation of correction factors for reading of thermoluminescent dosimeters utilized in the measurement of deep doses, contributing for the reduction of uncertainties associated with quality control of clinical beams in radiotherapy.


Subject(s)
Monte Carlo Method , Radiotherapy , Spectrum Analysis , Radiation Dosimeters , Quality Control
16.
Korean Journal of Medical Physics ; : 60-69, 2010.
Article in Korean | WPRIM | ID: wpr-30103

ABSTRACT

For treatment of Total Skin Electron beam Therapy (TSET), measurement of dose at various conditions is need on the contrary to usual radiotherapy. When treating TSET with modified Stanford technique based on linear accelerator, the energy of treatment electron beam, the spatial dose distribution and the actual doses deposited on the surface of the patient were measured by using EBT2. The measured energy of the electron beam was agreed with the value that measured by ionization chamber, and the spatial dose distribution at the patient position and the doses at several point on the patient's skin could be easily measured by EBT2 film. The dose on the patient that was measured by EBT2 film showed good agreement with the data measured simultaneously by TLD. With the results of this study, it was proven that the EBT2 film can be one of the useful dosimeter for TSET.


Subject(s)
Humans , Electrons , Particle Accelerators , Skin
17.
Korean Journal of Medical Physics ; : 308-316, 2009.
Article in Korean | WPRIM | ID: wpr-227381

ABSTRACT

To achieve the accurate evaluation of given absorbed dose from output dose of linear accelerator photon beam through investigate the characteristics of LiF:Mg,Cu,P TLD powder. This experimental TL phosphor is performed with a commercial LiF:Mg,Cu,P powder (Supplied by PTW) and TL reader (LTM, France). The TLD was exposed to 6 MV X rays of linear accelerator photon beam with range 15 to 800 cGy in blind dose at two hospitals. The dose evaluation of TLD was through the experimental algorithms which were dose dependency, dose rate dependency, fading and powder weight dependency. The glow curve has shown the three peaks which are 110, 183 and 232 degrees of heating temperature and the main dosimetric peak showed highest TL response at 232 high temperature. In this experiments, the LiF:Mg,Cu,P phosphor has shown the 2.5 eV of electron trap energy with a second order. This experiments guided the dose evaluation accuracy is within 1% +2.58% of discrepancy. The TLD powder of LiF:Mg,Cu,P was analyzed to dosimetric characterists of electron captured energy and order by glow shape, and dose-TL response curve guided the accuracy within 1.0+2.58% of output dose discrepancy.


Subject(s)
Dependency, Psychological , Electrons , Heating , Hot Temperature , Particle Accelerators
18.
Korean Journal of Medical Physics ; : 152-158, 2009.
Article in Korean | WPRIM | ID: wpr-137641

ABSTRACT

Total Skin Electron Beam Therapy (TSEBT) of linear accelerator has become use so as to be useful, 2~9 MeV of energy territories came to be used with mycosis fungoides and cutaneous lymphomas in the superficial lesion treatment which covers the major portion of the body. I treat a patient to Stanford technique in this study, and it is 60 degrees around the patients whom Stanford technique irradiated electronic beam to a linear accelerator in horizontal directions and there is a way a standard of TSEBT treat it to six located field (anterior, posterior, and four obliques) becoming. An each field does horizontally it and consist to beam of the two component which fitted the center to a suitable angle. a patient treats it to three dual field a day in order to make short treatment time. when a first day, we treat one dual field at anterior position and two dual field at posterior position. when the second day, treat one dual field at posterior position and two dual field at anterior position. Therefore, six dual field is finished in perfect periodic two days. we made cylindrical acrylic phantom, and I inserted a dosimeter film between phantom. in order to measure a dose distribution calculation before treat a patient, and a patient checked it in six field directions that got from a treatment. It is after that thermoluminescent dosimetry (TLD) as it uses Rando phantom and then measurement dose distribution in six field directions after attaching at chest, the right and left flank, a back after irradiation.


Subject(s)
Humans , Electronics , Electrons , Leukemia, Myeloid , Leukemia, Myeloid, Acute , Lymphoma , Mycosis Fungoides , Particle Accelerators , Porphyrins , Skin , Thermoluminescent Dosimetry , Thorax
19.
Korean Journal of Medical Physics ; : 152-158, 2009.
Article in Korean | WPRIM | ID: wpr-137640

ABSTRACT

Total Skin Electron Beam Therapy (TSEBT) of linear accelerator has become use so as to be useful, 2~9 MeV of energy territories came to be used with mycosis fungoides and cutaneous lymphomas in the superficial lesion treatment which covers the major portion of the body. I treat a patient to Stanford technique in this study, and it is 60 degrees around the patients whom Stanford technique irradiated electronic beam to a linear accelerator in horizontal directions and there is a way a standard of TSEBT treat it to six located field (anterior, posterior, and four obliques) becoming. An each field does horizontally it and consist to beam of the two component which fitted the center to a suitable angle. a patient treats it to three dual field a day in order to make short treatment time. when a first day, we treat one dual field at anterior position and two dual field at posterior position. when the second day, treat one dual field at posterior position and two dual field at anterior position. Therefore, six dual field is finished in perfect periodic two days. we made cylindrical acrylic phantom, and I inserted a dosimeter film between phantom. in order to measure a dose distribution calculation before treat a patient, and a patient checked it in six field directions that got from a treatment. It is after that thermoluminescent dosimetry (TLD) as it uses Rando phantom and then measurement dose distribution in six field directions after attaching at chest, the right and left flank, a back after irradiation.


Subject(s)
Humans , Electronics , Electrons , Leukemia, Myeloid , Leukemia, Myeloid, Acute , Lymphoma , Mycosis Fungoides , Particle Accelerators , Porphyrins , Skin , Thermoluminescent Dosimetry , Thorax
20.
Korean Journal of Medical Physics ; : 88-96, 2009.
Article in Korean | WPRIM | ID: wpr-115853

ABSTRACT

Radiation treatment for skin cancer has recently increased in tomotherapy. It was reported that required dose could be delivered with homogeneous dose distribution to the target without field matching using electron and photon beam. Therapeutic beam of tomotherapy, however, has several different physical characteristic and irradiation of helical beam is involved in the mechanically dynamic factors. Thus verification of skin dose is requisite using independent tools with additional verification method. Modified phantom for dose measurement was developed and skin dose verification was performed using inserted thermoluminescent dosimeters (TLDs) and GafChromic EBT films. As the homogeneous dose was delivered to the region including surface and 6 mm depth, measured dose using films showed about average 2% lower dose than calculated one in treatment planning system. Region indicating about 14% higher and lower absorbed dose was verified on measured dose distribution. Uniformity of dose distribution on films decreased as compared with that of calculated results. Dose variation affected by inhomogeneous material, Teflon, little showed. In regard to the measured dose and its distribution in tomotherapy, verification of skin dose through measurement is required before the radiation treatment for the target located at the curved surface or superficial depth.


Subject(s)
Electrons , Polytetrafluoroethylene , Radiotherapy, Intensity-Modulated , Skin , Skin Neoplasms