Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 293-297, 2017.
Article in Chinese | WPRIM | ID: wpr-808441

ABSTRACT

Objective@#To establish an animal model of hard metal lung disease (HMLD) in rats, and to screen the indications for diagnosis of HMLD.@*Methods@#The rats were randomly divided into 5 groups, each group included 8 rats: saline group, pure cobalt group, pure tungsten carbide group, silica group and hard metal (HM) group. 10 mg subjects were administered in each group by using the pulmonary endotracheal tube. After 8 week, the lung CT scan and lung tissue pathology were observed, the serum and bronchoalveolar lavage fluid (BALF) were collected for KL-6, TGF-beta1 and TGF-beta2.@*Results@#The lung tissue structure of HM group was destroyed, a large number of nuclear giant cells and epithelial like cells appeared in the stroma, and uncommon CT scan images appeared in the lung. KL-6, TGF-beta1, TGF-beta2 expression in each group was not the same, the difference was statistically significant (P<0.05) . The expression of KL-6 and TGF-beta1 in serum was not identical in all the groups, the difference was statistically significant (P<0.05) . The expression of TGF-beta2 had no significant difference between the groups (P>0.05) .@*Conclusion@#Rats can be successfully established HMLD model, rats in vivo lung CT scan images appear abnormal, which are provided with assistant diagnostic value for HMLD. The expression of KL-6 and TGF-beta2 in serum and BALF on HMLD rats are not highly specific, and TGF-beta1 has reference value in the rat HMLD auxiliary diagnosis.

2.
Chongqing Medicine ; (36): 3503-3504, 2013.
Article in Chinese | WPRIM | ID: wpr-441411

ABSTRACT

Objective To observe the effect of several residual adhesive methods on the enamel surface ,and conduct lab evalua-tion .Methods Sixty premolars extracted because of orthodontic treatment .And all the teeth were randomly divided into 3 groups . Group 1:tungsten carbide burs + silicon particles ;Group 2 :ultrasonic scaling + silicon particles ;Group 3:silicon particles ,each with 20 premolars .After underwent several methods ,the surface roughness differences ,operation time were determined and ob-served with the scanning electron microscope .And the result was statistically analyzed .Results There were significant differences in the surface roughness and operation time among the three groups (P<0 .05) ,The scanning electron microscope after polishing showed that the teeth surface had different degrees of injury ,the silica particles group had less superficial scratch .Conclusion The tungsten carbide burs and ultrasonic instrument for debonding before the silica particles had less superficial scratch .

3.
Rev. odontol. UNESP (Online) ; 40(4): 166-173, jul.-ago. 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-614423

ABSTRACT

Introdução: Atualmente, existem muitas dúvidas em relação aos métodos de limpeza de fresas, o que estimula o estudo desses métodos visando maior eficiência e menor prejuízo desses instrumentos rotatórios. Objetivo: Avaliar a influência de métodos de limpeza sobre a eficiência de corte e sobre as características morfológicas de fresas de açoinoxidável de carbeto de tungstênio (carbide). Material e método: Trinta fresas foram divididas em cinco grupos (n = 6), de acordo com o método de limpeza: L1- escova de aço; L2- escova de nylon; L3- ultrassom + água destilada; L4- ultrassom + solução desincrustante; L5- nenhum método de limpeza (controle). As fresas foram utilizadas para o corte de esmalte dental bovino durante seis períodos de 12 minutos cada. Após cada período, as fresas eram limpas (exceto L5) seguindo o protocolo estabelecido para cada grupo. A eficiência de corte foi determinada pelo método da perda de massa e as características morfológicas, por meio de análise fotomicrográfica. Resultado: As médias da quantidade de desgaste após 72 minutos de uso foram: L1 = 0,3558 g; L2 = 0,4275 g; L3 = 0,4652 g; L4 = 0,4396 g, e L5 = 0,4854 g. Houve diferença significante para o tempo de uso (p < 0,001) e o método de limpeza (p < 0,001). O grupo L1 apresentou pior desempenho. Independentemente do grupo experimental, a análise morfológica revelou alterações nas lâminas de corte a partir de 12 minutos, sendo o grupo L1 o mais afetado. Conclusão: O método mais prejudicial à eficiência de corte e que mais alterou as características morfológicas das fresas carbide foi a limpeza com escova de aço.


Introduction: Currently, there are many questions regarding the cleaning methods seeking greater efficiency and less loss of burs. Aim: the aim of this study was to evaluate the influence of cleaning methods on the cutting efficiency and morphological characteristics of stainless steel burs tungsten carbide (carbide). Materials and method: Thirty burs were divided into five groups (n = 5) according with the cleaning method: L1- steel brush, L2- nylon brush, L3- ultrasound + distilled water, L4- ultrasound + descaling solution and L5- no cleaning method (control). Theburs were used for the cutting of bovine enamel during six periods of 12 minutes each. After each period, the burs were cleaned (except L5) following the protocol established for each group. The cutting efficiency was determined by mass loss and morphological characteristics. Result: The average amount of wear after 72 minutes of use were L1 = 0.3558 g; L2 = 0.4275 g; L3 = 0.4652 g; L4 = 0.4396 g e L5 = 0.4854 g; significant differences in the time of use (p < 0.001) and cleaning method (p < 0.001). The L1 group showed the worst performance. Regardless of theexperimental group, morphological analysis revealed alterations in the cutting blades soon after the first 12 minutes, being L1 the most affected group. Conclusion: The cleaning with wire brush was the most damaging method to the cutting efficiency and to the morphology of carbide burs.


Subject(s)
Stainless Steel , Ultrasonics , Tungsten Compounds , Dental Instruments , Efficiency , Analysis of Variance , Statistics, Nonparametric
4.
Annals of Dentistry ; : 1-7, 2011.
Article in English | WPRIM | ID: wpr-627413

ABSTRACT

The aim of this study was to assess the wear of tungsten carbide burs and round rotary diamond instruments through measurements of rake angle and visual observations respectively under a f ield emission scanning electron microscope. Sixty short and long head pear-shaped tungsten carbide burs and 18 round rotary diamond instruments that had been used to complete 5 and > 10 cavity preparations (n=10/ group) were selected from the 3rd and 4th year dental students, Faculty of Dentistry, University of Malaya. There were two control groups consisting of long and short tungsten carbide burs of ten each. Two-way ANOVA was used to analyse the rake angle data. The data from the two control groups were collectively analysed following multiple paired t-test (p > .05) which showed no significant difference between the two types of tungsten carbide bur (short and long head). The mean rake angle of the control group was significantly higher (p 5 and > 10 cavity preparation groups. The rake angle of the > 10 cavity preparation group was significantly lower than the other two test groups (p 5 and > 10 cavity preparation groups showed blunt diamond particles. In conclusion, wear of tungsten carbide burs and round rotary diamond instruments were evident after repeated use. Wear was more pronounced when instruments were used to prepare more than ten cavities.

5.
The Journal of Korean Academy of Prosthodontics ; : 229-242, 2006.
Article in Korean | WPRIM | ID: wpr-224436

ABSTRACT

STATEMENT OF PROBLEM: In order to increase preload with reducing the friction coefficient, abutment screws coated with pure gold and Teflon as dry lubricant coatings have been introduced. But the reported data indicate that if screw repeated tightening and loosening cycle, an efficiency of increasing preload was decreased by screw surface wearing off. PURPOSE: This study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on the preload of abutment screws and the stability of coating surface after repeated closures. MATERIAL AND METHOD: The rotational values of abutment screws and the compressive forces between abutment and fixture were measured in implant systems with three different joint connections, one external butt joint and two internal cones. Moreover, the stability and the alteration of coating surface were examined by comparison of the compressive force and the removable torque values during 10 consecutive trials, observation with scanning electron microscope and analyzed the elemental composition with energy dispersive x-ray spectroscopy. RESULTS AND CONCLUSION: 1. Application of coating resulted in significant increase of compressive force in all implant systems(P.05). 3. Removable torque values were greater with non-coated screw than that with coated screw (P.05). 5. After repeated trials, the surface layer of coated screw was maintained relatively well. However, surface wearing and irregular titanium fragments were found in non-coated screw.


Subject(s)
Friction , Hardness , Joints , Polytetrafluoroethylene , Spectrometry, X-Ray Emission , Titanium , Torque , Tungsten
6.
The Journal of Korean Academy of Prosthodontics ; : 740-750, 2006.
Article in English | WPRIM | ID: wpr-109146

ABSTRACT

STATEMENT OF PROBLEMS: In an attempt to reduce screw loosening, dry lubricant coatings such as pure gold or tefron have been applied to the abutment screw. However, under repeated tightening and loosening procedures, low wear resistance and adhesion strength of coating material produced free particles on the surface of abutment screw and increased frictional resistance resulting in screw tightening problems. PURPOSE: The aim of this study was to compare friction coefficient, adhesion strength, vickers hardness and evaluate coating surface of titanium alloy specimens coated with TiN(titanium nitride), ZrN(zirconium nitride) and WC(tungsten carbide). MATERIAL AND METHOD: Titanium alloy(Ti-6Al-4V) discs of 12mm in diameter and 1mm in thickness divided into 4 groups. TiN, ZrN and WC was coated for the specimens of 3 groups respectively, and those of 1 group were not coated. Each group was made up of 4 specimens. In this study, sputtering method was used among the PVD(Physical Vapor Deposition) techniques available for TiN, ZrN and WC coatings. Friction coefficient, adhesion strength, vickers hardness and coating surface of 4 groups were measured. RESULTS: 1. For all three coating conditions, friction coefficient was significantly decreased. Especially, ZrN coated surface showed the lowest value. TiN(0.39+/-0.02), ZrN(0.24+/-0.01), WC(0.31+/-0.03). 2. TiN coating showed the highest adhesion strength, however ZrN coating had the lowest value. TiN(25.3N+/-1.6), ZrN(14.8N+/-0.6), WC(18.4N+/-0.7). 3. Vickers hardness of all three coatings was remarkably increased as compared with that of none coated specimen. TiN coating had the highest Vickers hardness, however WC coating showed the lowest value. TiN(1865.2+/-33.8), ZrN(1814.4+/-18.6), WC(1008.5+/-35.9). 4. The ZrN or WC coated specimen showed a homogeneous and smooth surface, however the rough surface with defects was observed for TiN coating. CONCLUSIONS: When TiN, ZrN and WC coating applied to the abutment screw, frictional resistance would be reduced, as a result, the greater preload and prevention of the screw loosening could be expected.


Subject(s)
Alloys , Friction , Hardness , Tin , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL