Fisioter. Mov. (Online) ; 37: e37117, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1557766

ABSTRACT

Abstract Introduction Ultrasound used in diathermic therapies aims to achieve temperatures between 40 and 45 °C, since temperatures above 45 °C are known to cause tissue necrosis and burns. Many studies have been conducted to investigate the effect of therapeutic ultrasound in the presence of metallic implants, using phantoms (test samples) and in vivo and ex vivo animal models. In most of these studies, the ultrasound probe is fixed in one area, while in clinical practice, it is recommended that it be moved to avoid possible local overheating. Objective To analyze the thermal field at the muscle-bone interface in phantoms in the presence or absence of metallic implants after the application of therapeutic ultrasound. Methods Phantoms composed of layers simulating fat and muscle, and a layer of beef rib bone, with and without a titanium metallic implant, were prepared. The experiment involved different intensities (1.0, 1.5, and 2.0 W/cm2) and exposure times (5 and 10 minutes), common in clinics, with linear scanning of the probe. Results The experiments indicated that the muscle/implant interface heated less than the muscle/bone interface, especially at intensities of 1.5 and 2.0 W/cm2, after 5 and 10 minutes of treatment. Conclusion The results suggest the possibility of using therapeutic ultrasound in patients with metallic implants, encouraging future research to develop evidence-based protocols and safe recommendations in physiotherapy.


Resumo Introdução O ultrassom utilizado em terapias diatérmicas visa atingir temperaturas entre 40 e 45 °C, sabendo-se que temperaturas acima de 45 °C podem causar necrose tecidual e queimaduras. Muitas pesquisas têm sido realizadas para estudar o efeito do ultrassom terapêutico na presença de implantes metálicos, utilizando phantoms (corpos de prova) e animais in vivo e ex vivo. Na maioria dessas pesquisas, o cabeçote ultrassônico está fixo em uma área, enquanto que na prática clínica recomenda-se que ele seja movimentado para evitar eventuais sobreaquecimentos locais. Objetivo Analisar o campo térmico na interface músculo-osso em phantoms na presença ou ausência de implantes metálicos após a aplicação do ultrassom terapêutico. Métodos Foram elaborados phantoms compostos de camadas simuladoras de gordura e músculo e de uma camada de osso de costela bovina, sendo esta com e sem implante metálico de titânio. O experimento envolveu diferentes intensidades (1.0, 1.5 e 2.0 W/cm2) e tempos de exposição (5 e 10 minutos) comuns em clínica, com varredura linear do cabeçote. Resultados Os experimentos indicaram que a interface músculo/implante aqueceu menos do que a interface músculo/osso, especialmente nas intensidades de 1.5 e 2.0 W/cm2, após 5 e 10 minutos de tratamento. Conclusão Os resultados obtidos apontam para a possibilidade de utilização do ultrassom terapêutico em pacientes com implantes metálicos, incentivando pesquisas futuras para desenvolver protocolos baseados em evidências e recomendações seguras na fisioterapia.

2.
Rev. Pesqui. Fisioter ; 9(2): 166-173, Maio 2019. tab, ilus
Article in English, Portuguese | LILACS | ID: biblio-1150891

ABSTRACT

INTRODUÇÃO: A amamentação constitui uma importante etapa no processo reprodutivo, oferecendo benefícios tanto para mãe como para a criança. O Ingurgitamento mamário é uma complicação que ocorre do terceiro ao quinto dia de pós-parto. O Ultrassom Terapêutico (UST) é amplamente utilizado, e consiste em um aparelho capaz de produzir energia acústica de alta frequência. OBJETIVO: verificar o efeito agudo do ultrassom no processo terapêutico do ingurgitamento mamário. METODOLOGIA: Estudo transversal, que avaliou a mama e classificou o ingurgitamento, além de realizar avaliação da dor e da percepção subjetiva das mamas. Foi administrado o protocolo com ultrassom terapêutico na frequência de 1Mh, modo pulsado, intensidade/ dose de 0,5w/cm2, ciclo ativo de 20% com tempo de aplicação de 02 minutos por área de radiação efetiva (ERA). Após aplicação, a lactente foi submetida à amamentação e realizada nova avaliação das mamas. RESULTADOS: A amostra foi composta por 4 mulheres entre 20 e 30 anos com quadro de ingurgitamento mamário. O valor inicial do ingurgitamento mamário foi de 2 a mediana e a final foi de 1 a mediana. Em relação à dor mamária, inicialmente foi de 5 mediana e a final 2 a mediana. Em todos os casos analisados houve melhora na dor, na disponibilidade do leite e no aspecto de ingurgitamento da mama. CONCLUSÃO: O ultrassom terapêutico se mostrou eficaz na redução da dor, no aumento da disponibilidade do leite e na melhora do enrijecimento característico do ingurgitamento mamário.


INTRODUCTION: Breastfeeding is an important step in the reproductive process, providing benefits for both mother and child. Breast engorgement is a complication that occurs from the third to the fifth postpartum day. Therapeutic Ultrasound (UST) is widely used, and consists of an apparatus capable of producing high frequency acoustic energy. OBJECTIVE: to verify the acute effect of ultrasound in the therapeutic process of breast engorgement. METHODOLOGY: Cross-sectional study, which evaluated the breast and classified the engorgement, besides evaluating the pain and the subjective perception of the breasts. The protocol with therapeutic ultrasound was administered at a frequency of 1Mh, pulsed mode, intensity / dose of 0.5w / cm2, active cycle of 20% with application time of 02 minutes per effective Radiation Area (ERA). After application, the infant was submitted to breastfeeding and a new breast evaluation was performed. RESULTS: The sample consisted of 4 women between 20 and 30 years of age with breast engorgement. The initial value of breast engorgement was 2 the median and the final value was 1 to median. Regarding breast pain, it was initially 5 median and the final 2 median. In all the analyzed cases there was improvement in pain, milk availability and breast engorgement aspect. CONCLUSION: Therapeutic ultrasound has been shown to be effective in reducing pain, increasing milk availability and improving the stiffness characteristic of breast engorgement.


Subject(s)
Ultrasonic Therapy , Breast , Breast Feeding
3.
Rev. para. med ; 27(3)jul.-set. 2013.
Article in Portuguese | LILACS-Express | LILACS | ID: lil-702825

ABSTRACT

verificar com base na literatura a eficácia do ultrassom terapêutico, modo pulsado, como recurso para auxiliarna consolidação de fraturas. Método: revisão bibliográfica com levantamento em bancos de dados do SCIELO,LÍLACS e biblioteca da Universidade da Amazônia, no período de 1999 a 2011. Considerações finais: observou-seque poucas referências bibliográficas utilizaram o UST, modo contínuo, no tratamento de consolidação óssea. Porém,os efeitos benéficos são significativos em UST modo pulsado, sobretudo em baixa intensidade, o que minimiza o riscode lesões teciduais e a formação de cavitações. Diante de questionamentos ainda existentes quanto ao tempo, à dosimetriae ao modo de aplicação do US, sugere-se que mais pesquisas sejam realizadas, pois as mesmas apresentam grandevariação na literatura.


to determine, based on the literature, the effectiveness of therapeutic ultrasound for high and low .and itsproper way to treat fracture healing. Methods: A systematic review of scientific articles published in the period 1999 to2011 related to the subject indexed in databases Scielo and Lilacs. Final thoughts: There are few literatures UST usedcontinuously in the treatment of bone healing. The beneficial effects are significant, especially at low intensity, whichminimizes the risk of tissue lesions and cavitations. Faced with questions still exist as to time, the dosimetry and themode of application of the U.S., it is suggested more research, because they vary greatly in the literature.

4.
Fisioter. mov ; 25(4): 857-868, out.-dez. 2012. graf, tab
Article in Portuguese | LILACS | ID: lil-660508

ABSTRACT

INTRODUÇÃO: O ultrassom (US) terapêutico atua nos tecidos biológicos por meio da vibração, que é capaz de produzir efeitos fisiológicos térmicos e não térmicos. OBJETIVO: Discutir os parâmetros que afetam o aquecimento dos tecidos biológicos, decorrente da aplicação do US. MATERIAIS E MÉTODOS: Efetuou-se levantamento bibliográfico nas bases de pesquisa ISI WEB e SCOPUS. Foram selecionados os artigos, na língua inglesa, que tiveram como ponto central, o estudo da variação da temperatura após a aplicação do US em humanos. RESULTADOS: Foram observadas variações significativas em relação ao aumento de temperatura tecidual. Para a frequência de 3MHz, ocorre um aumento médio de 2,6 ºC nos tecidos superficiais; e para 1MHz, há um aumento médio de 1,7 ºC em tecidos profundos. Há um maior aquecimento do tecido em relação ao tamanho da ERA (área de radiação efetiva), quanto menor o tamanho maior o aquecimento. Também há um aumento da temperatura em relação às intensidades. Intensidades variando entre 0,5 a 3 W/cm² apresentam um acréscimo significativo de temperatura. Em relação à forma de aplicação, o gel proporciona melhor acoplamento, gerando maior aquecimento com um tempo de aplicação de cinco minutos - o tempo de aplicação deve ser adequado à área de tratamento e à densidade de potência. Entretanto, a velocidade de aplicação parece não modificar o aquecimento até 7-8 cm/s, mesmo que dispositivos diferentes aqueçam em níveis diferentes. CONCLUSÃO: Os parâmetros para a aplicação do US devem ser controlados e ajustados para produzir o aquecimento profundo dos tecidos considerando a variação entre dispositivos.


INTRODUCTION: The therapeutic ultrasound act in biological tissues by means of vibration can produce physiological effects of thermal and non-thermal. OBJECTIVE: To discuss the parameters that affect the heating of biological tissues by ultrasound. MATERIALS AND METHODS: We conducted a literature research based on ISI Web and SCOPUS database. We selected the articles in the English language that have studied the temperature variation after the application of ultrasound in humans. RESULTS: There are significant variations related to tissue-temperature rise. For the 3MHz ultrasound, there is an average increase of 2.6 ºC in superficial tissues, and to the 1MHz US, there is an average increase of 1.7 ºC in deep tissues. There is a higher heating of the treated tissue when an area twice the ERA (effective radiating area) size, the shorter the higher the heating, there is an increase in temperature relative intensities. Intensities ranging from 0.5 to 3 W/cm² have a significant increase in temperature. Regarding the mode of application, the gel provides an improved coupling, generating more heat with an application time of five minutes - the application time depends on the treatment area and power density. However, the speed of application appears to modify the heating up to 7-8 cm/s. Also, different commercial devices produce heat differently. CONCLUSION: Parameters for ultrasound application must be controlled and adjusted to generate deep heating of tissues considering that it may vary among devices.


Subject(s)
Temperature , Ultrasonics
5.
Fisioter. mov ; 25(1): 21-29, jan.-mar. 2012. ilus, graf
Article in Portuguese | LILACS | ID: lil-623257

ABSTRACT

INTRODUÇÃO: Existe um grande interesse no estabelecimento de recursos e terapias a serem utilizados na tentativa de proporcionar um processo de reparo muscular de melhor qualidade e menor duração. O ultrassom terapêutico (US) e o laser de baixa potência (LBP) são recursos muito usados na prática clínica, porém são escassas, e por vezes contraditórias, as evidências científicas que determinam com segurança os parâmetros dosimétricos e metodológicos adequados. OBJETIVOS: O objetivo do estudo foi analisar o efeito do US e do LBP sobre a proliferação celular durante a diferenciação de mioblastos C2C12. MATERIAIS E MÉTODOS: Os mioblastos foram cultivados em meio de cultura de Eagle modificado por Dulbecco, contendo 10% de soro fetal bovino (SFB), sendo induzida a diferenciação pela adição de 2% de soro de cavalo durante 96 horas. Posteriormente, as células foram irradiadas com US pulsado a 20%, 3 MHz de frequência (intensidades de 0,2 e 0,5 W/cm², durante cinco minutos) ou submetidas ao tratamento com LBP (potência de saída de 10 mW, densidade de energia de 3 e 5 J/cm², por 20 segundos). A proliferação celular foi avaliada após 24h e 72h utilizando o método de MTT. Foram realizados três experimentos independentes, em cada condição citada e células não irradiadas serviram como controle. RESULTADOS: Os resultados obtidos foram submetidos à análise estatística utilizando a Análise de Variância (ANOVA), teste Dunnet, para verificar diferenças entre o grupo controle (não tratado) e os grupos tratados com US e LBP, adotando significância de p < 0,05. Os resultados evidenciaram que não houve diferença significativa na proliferação celular entre as células musculares submetidas a tratamento com ambos os recursos terapêuticos e as células controle, nos períodos de 24h e 72h após tratamento. Além disso, foi possível verificar que não houve aumento significativo no número de células após o período de 72h quando comparado a 24h, confirmando o processo de diferenciação celular, conforme esperado. CONCLUSÕES: Conclui-se que o US e o LBP, nos parâmetros avaliados, não alteraram a proliferação de mioblastos em processo de diferenciação.


INTRODUCTION: There is great interest in establishing resources and therapies to be used in an attempt to provide a process of muscle repair better and shorter. Two features commonly used to facilitate the healing process are the therapeutic ultrasound and laser power, however, are still scarce and sometimes contradictory scientific evidence to determine with certainty the parameters and methodology necessary to acquire these goals. OBJECTIVES: Thus, the objective of present study was to evaluate the effect of therapeutic ultrasound (US) and low level laser GaAlAs 660 nm on the proliferation of C2C12 myoblasts. MATERIALS AND METHODS: The myoblasts were cultivated in culture medium of Eagle modified by Dulbecco, containing 10% fetal bovine serum (FBS) and induced to differentiate by addition of 2% horse serum for 96h. Subsequently, cells were irradiated with US (20%, 3 MHz, and intensities of 0.2 and 0.5 W/cm² for five minutes) or with LLL (output power of 10 mW, density of 3 and 5 J/cm² for 20 seconds). The non-irradiated cells serve as controls. Three independent experiments were performed for each condition cited. Cell proliferation was evaluated after 24h and 72h using the MTT method. RESULTS: The results were statistically analyzed using analysis of variance (ANOVA/Dunnet) to verify differences between control cells (untreated) and US/LLL treated groups. The results showed no significant differences in viability and cell proliferation between LLL or US treated cells and control cells after 24h and 72h. Furthermore, it was observed no increase in the number of cells within the evaluation period after treatment, confirming the process of cell differentiation, as expected. RESULTS: In conclusion, US and the LLL, employed under the parameters described does not alter C2C12 proliferation.


Subject(s)
Lasers , Muscle Cells , Myoblasts , Cell Proliferation , Ultrasonics
6.
Braz. j. phys. ther. (Impr.) ; 14(2): 114-120, Mar.-Apr. 2010. ilus, tab, graf
Article in English, Portuguese | LILACS | ID: lil-549361

ABSTRACT

CONTEXTUALIZAÇÃO: O Ultrassom (US) é um dos recursos físicos amplamente utilizado e pesquisado nos tratamentos de fisioterapia. Sabe-se que diante de uma escassa literatura sobre efeitos do US em tecidos sadios, muitos profissionais fisioterapeutas acabam realizando aplicações infundadas de métodos e parâmetros. OBJETIVO: Avaliar possíveis alterações histológicas e morfométricas do tecido sadio in vivo de ratos Wistar irradiados com diferentes intensidades de US. MÉTODOS: Trinta ratos da linhagem Wistar, distribuídos aleatoriamente em cinco grupos de seis animais cada foram tratados na região dorsal do lado direito numa área de 4cm². O lado esquerdo serviu como controle. O tratamento foi feito durante quatro dias com 2 minutos de irradiação. Verificou-se a intensidade de saída com dosímetro de precisão antes das aplicações. Analisou-se a histologia e a morfometria por meio do software Image Tool. RESULTADOS: Observou-se um discreto infiltrado inflamatório e adelgaçamento das fibras da derme, principalmente dos grupos irradiados com 1.5 e 2W/cm². Notou-se também um aumento na espessura da epiderme nas amostras dos animais irradiados. Para avaliar os resultados quantitativos, utilizou-se como análise estatística ANOVA one way e o teste post hoc de Tukey. Na espessura da epiderme, obtiveram-se diferenças significativas entre grupo controle e os grupos irradiados com 1.0, 1.5 e 2.0W/cm². CONCLUSÃO: Sob ação do US nas doses maiores houve alterações na epiderme e derme, respectivamente, o aumento da espessura e proliferação com adelgaçamento das fibras colágenas, o que alerta para possíveis implicações do uso do US em estética.


BACKGROUND: Ultrasound (US) is a widely used and studied resource for physical therapy treatments. Given the scarcity of studies on the effects of US on healthy tissue, many physical therapy professionals make unfounded decisions regarding its methods and parameters of application. OBJECTIVES: The possible histological and morphometric changes in the healthy tissue of Wistar rats in vivo irradiated with different intensities of US were evaluated. METHODS: Thirty Wistar rats, randomly distributed among five groups of six animals each, were treated on the right side of the dorsal region, over an area of 4 cm². The left side served as a control. The treatment was applied over a four-day period, with two mins. of daily irradiation. The output intensity was checked using a precision dosimeter before the applications. Histological and morphometric analyses were performed using the Image Tool software. RESULTS: There were slight inflammatory infiltration and thinning of the dermis fibers, particularly in the groups irradiated with 1.5 and 2 W/cm². There was also thickening of the epidermis in the samples from the irradiated animals. To evaluate the quantitative results, the statistical analyses consisted of one-way ANOVAs with the post-hoc Tukey tests. There were significant differences in epidermis thicknesses between the control group and the groups irradiated with 1.0, 1.5 and 2.0 W/cm². CONCLUSIONS: Higher doses of US produced changes in the epidermis and dermis, i.e. increased thickness and collagen fiber thinning and proliferation, respectively. These results serve as a warning of the possible implications of therapeutic ultrasound use in esthetics.


Subject(s)
Animals , Rats , Epithelium/anatomy & histology , Epithelium/radiation effects , Ultrasonic Therapy/methods , Rats, Wistar
7.
Rev. bras. med. esporte ; 15(6): 424-427, nov.-dez. 2009. ilus
Article in Portuguese | LILACS | ID: lil-533661

ABSTRACT

A ciática possui grande prevalência geral e seu tratamento tende a resolver as causas de compressão nervosa. A fisioterapia objetiva reduzir os sintomas causados pela compressão. O presente estudo teve como objetivo avaliar a eficácia do ultrassom terapêutico sobre a dor, em animais submetidos a modelo experimental de ciatalgia. Foram usados 18 ratos neste estudo, divididos em três grupos: GS (n = 4), submetido a modelo de ciatalgia e tratados com ultrassom desligado; GUP (n = 7), submetido à ciatalgia e tratados com ultrassom pulsado 2W/cm² (SATP; 0,4 - SATA); e grupo GUC (n = 7), submetido à ciática e ultrassom contínuo (0,4W/cm²). O nervo ciático do membro posterior direito foi exposto à compressão com fio categute em quatro pontos. No 3º dia pós-operatório (PO), iniciou-se tratamento indireto por quatro dias. No 9º dia PO, o tratamento direto começou sobre a área do procedimento cirúrgico, por cinco dias consecutivos. O tempo de elevação da pata, durante a marcha, foi avaliado antes e após a ciatalgia, no 3º, 6º, 9º e 13º PO. Os resultados demonstraram que a aplicação do ultrassom reduziu a dor com ambos os tratamentos efetivos e tendeu a ser mais eficaz na forma pulsada.


The sciatica possesses great general population prevalence, and its treatment tends to solve the nervous compression causes. Physiotherapy aims to reduce the symptoms caused by compression. This study aimed to evaluate the effectiveness of therapeutic ultrasound on pain in animals subjected to sciatica experimental model. Eighteen rats were used and they were divided in 3 groups: group SG (n=4) submitted to the sciatica and treated with the ultrasound off, group PUG (n=7) submitted to the sciatica and treated with pulsed ultrasound 2 W/cm² (SATP; 0,4 - SATA) and group CUG (n=7) submitted to the sciatica and treated with continuous ultrasound (0,4 W/cm²). The sciatic nerve of the posterior right limb was exposed to the compression with Catgut wire in 4 points. In the 3rd postoperative day, the indirect treatment was started (right inferior limb) for four days. In the 9th postoperative day, the direct treatment begins on the surgical procedure area for 5 serial days. The paw elevation time, during the march, of the animal was verified before and after the sciatica, at the 3rd, 6th, 9th and 13th postoperative day. The results demonstrated that the application of the therapeutic ultrasound reduced the pain with both treatments in PUG and CUG, and it has tended larger effectiveness in the pulsed form.