Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 170
Filter
1.
Braz. j. biol ; 842024.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469374

ABSTRACT

Abstract The present study aimed to investigate the beneficial of prepared black rice anthocyanins nano-composite (An-AgNps) against hepatotoxicity induced by methotrexate (MTX) in rats. Anthocyanins nano-composite was prepared by silver as the metallic ion reduction and were characterized by IR and SEM. The rats in our experiment were divided into five groups. Serum lipid profile, serum transaminases (ALT and AST), ALP, LDH, TBA, GSH and SOD were examined. The results show that SEM of An-AgNps has average particle size from 70 to 130nm. In the group treated with MTX; TC, TG, LDL-c, ALT, AST, ALP, LDH and TBA levels were significantly (P0.05) increased than NC, while, HDL-c, SOD and GSH levels were significantly (P0.05) decreased. On the other hand, An-AgNps + MTX treated groups were reversed the levels of all biomarkers similar to NC. In conclusion, the results show that An-AgNps has a protective effect on MTX-induced hepatotoxicity and oxidative stress.


Resumo O presente estudo teve como objetivo investigar o benefício de nanocompósito de antocianinas de arroz preto preparado (An-AgNps) contra a hepatotoxicidade induzida por metotrexato (MTX) em ratos. O nanocompósito de antocianinas foi preparado a partir da prata por meio da redução do íon metálico e caracterizado por IR e SEM. Os ratos em nosso experimento foram divididos em cinco grupos, e foram examinados o perfil lipídico sérico, as transaminases séricas (ALT e AST), ALP, LDH, TBA, GSH e SOD. Os resultados mostram que SEM de An-AgNps tem tamanho médio de partícula de 70 a 130 nm. No grupo tratado com MTX, os níveis de TC, TG, LDL-c, ALT, AST, ALP, LDH e TBA aumentaram significativamente (P 0,05) do que NC, enquanto os níveis de HDL-c, SOD e GSH diminuíram significativamente (P 0,05). Por outro lado, nos grupos tratados com An-AgNps + MTX, foram revertidos os níveis de todos os biomarcadores semelhantes ao NC. Em conclusão, os resultados mostram que o An-AgNps tem um efeito protetor contra a hepatotoxicidade induzida pelo MTX e o estresse oxidativo.

2.
Braz. dent. sci ; 27(1): 1-7, 2024. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1532450

ABSTRACT

Objective: The aim of this study was to determine if SEM used with imaging software could be used to quantitatively determine the extent of dentine roughness due to tooth-brushing. Material and methods: Flat, polished dentine surfaces were subjected to 25,000 cycles of simulated tooth-brushing at 2 strokes per second with a load of 200 g. At the end of the brushing cycle, dentine surfaces were first assessed using profilometry and then subjected to SEM analysis. Ra (average roughness) readings were obtained for profilometric assessment. Using imaging software, the horizontal distance between adjacent characteristic grooves noted on micrographs was measured, ensuring that the middle of each crest of the associated groove was used as the reference point, the Crest-to-Crest distance (C-C distance). These two parameters were examined statistically for correlation. Results: When Spearman Rank tests were utilized the correlation between average Ra and crest to crest measurements was 0.709 (p <0.01). The Bland Altman plot, however, showed poor agreement between the two test parameters. Conclusion: Further work is needed to validate the use of this methodology in the quantitative assessment of tooth surface loss due to abrasion (AU)


Objetivo: O objetivo deste estudo foi determinar se o MEV usado com software de imagem poderia ser usado para determinar quantitativamente a extensão da rugosidade da dentina devido à escovação dentária. Material e Métodos: Superfícies dentinárias planas e polidas foram submetidas a 25.000 ciclos de escovação dentária simulada a 2 movimentos por segundo com uma carga de 200g. No final do ciclo de escovação, as superfícies dentinárias foram primeiro avaliadas por perfilometria e depois submetidas à análise MEV. Leituras de Ra (rugosidade média) foram obtidas para avaliação perfilométrica. Utilizando um software de imagem, foi medida a distância horizontal entre sulcos característicos adjacentes observados nas micrografias, garantindo que o meio de cada crista do sulco associado fosse usado como ponto de referência, a distância crista a crista (distância CC). Esses dois parâmetros foram examinados estatisticamente para correlação. Resultados: Quando foram utilizados os testes de Spearman Rank, a correlação entre a média de Ra e as medidas de crista a crista foi de 0,709 (p<0,01). O gráfico de Bland Altman, no entanto, mostrou fraca concordância entre os dois parâmetros de teste. Conclusão: Mais trabalhos são necessários para validar o uso desta metodologia na avaliação quantitativa da perda da superfície dentária devido à abrasão(AU)


Subject(s)
Surface Properties , Tooth Abrasion , Toothbrushing , Microscopy, Electron, Scanning , Dentin
3.
Rev. nav. odontol ; 50(2): 5-14, 20232010.
Article in Portuguese, English | LILACS-Express | LILACS | ID: biblio-1518550

ABSTRACT

Considerando o uso de brocas para remoção da resina residual após descolagem do braquete e a possibilidade de injúrias à superfície do esmalte após o uso dessas brocas, este trabalho teve como objetivo realizar um estudo experimental, para avaliar a variação do aspecto superficial do esmalte de forma qualitativa, por meio da avaliação com imagens topográficas do esmalte dentário, utilizando-se a Microscopia Eletrônica de Varredura (MEV), a qual permitiu ilustrar e avaliar a superfície do esmalte após a fase de polimento final, realizada por dois métodos: taça de borracha ou escova Robinson. Foram utilizados 25 dentes pré-molares humanos, obtidos a partir de exodontias em pacientes que procuraram voluntariamente o curso de Residência em Cirurgia da Clínica Odontológica Universitária da Universidade Estadual de Londrina. Os dentes foram divididos em quatro grupos: A, B, C e D, contendo 6 dentes cada, de acordo com as brocas utilizadas para a remoção do remanescente adesivo e o polimento escolhido, além de um dente como "controle". Foi avaliada a rugosidade superficial do esmalte após a remoção da resina e a superfície do esmalte após o polimento com as duas opções apresentadas. Os resultados mostraram que, por observação e inspeção, as brocas removeram a resina residual de todos os dentes, porém, causaram riscos e ranhuras, como evidenciado nas imagens em MEV. Concluiu-se que não houve diferença estatística entre os métodos de polimento e que ambos foram importantes para a redução das marcas abrasivas, proporcionando uma superfície mais lisa do esmalte.


Considering the use of specific burs to remove residual resin after bracket debonding and the possibility of injuries to the dental enamel after using these burs, this study aimed to verify the variation in the enamel surface appearance in a qualitative way and evaluation with topographic images of the dental enamel. The use of Scanning Electron Microscopy (SEM) allowed to illustrate and evaluate the enamel surface after the final polishing phase using two methods: rubber cup or Robinson brush. Twenty-five human premolar teeth were obtained from extractions in patients who voluntarily sought the Oral Maxillofacial Surgery Residency at the Dental School from the State University of Londrina; the teeth were divided into four groups A, B, C and D containing 6 teeth each according to the burs used to remove the remaining adhesive and the chosen polishing, in addition to one tooth as a "control". Dental enamel surface roughness was evaluated after resin removal and enamel surface after polishing with the two methods presented. The results showed that by observation and inspection, the burs removed residual resin from all teeth, however, caused scratches and grooves as evidenced in the SEM images. Based on the results, there was no statistical difference between the polishing methods, and both were important for the reduction of abrasive marks and provided a smoother enamel surface.

4.
Braz. dent. sci ; 26(2): 1-8, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1426430

ABSTRACT

Objective: in this study, biofilm formation by Candida albicans in fixed orthodontic appliances was evaluated. Material and Methods: a total of 300 conventional metal brackets (MC), ceramic (CB), self-ligation (SLB), nickel-titanium (NiTi), and nickel-chromium (NiCr) wires, and ligatures types were organized into thirty groups (n=10). To induce biofilm formation, brackets, wires, and ligatures were joined, sterilized, placed in 24-well plates, contaminated with standardized suspensions of C. albicans (107 cells/mL), and incubated at 37 °C for 48 h with shaking. The biofilms formed were detached using an ultrasonic homogenizer, and suspensions were serially diluted and plated on Sabouraud dextrose agar to determine colony-forming units per mL. Scanning electron microscopy was performed before and after the biofilm formation. Results: lower amount of biofilm formation was observed in the MC group than in the CB and SLB groups (p<0.0001). SLB and CB showed similar biofilm formation rates (p=0.855). In general, the cross-sectional wires .018"x.025" showed higher biofilm formation when associated with the three types of brackets. When brackets, wires, and ligatures were associated, the sets with NiCr wires and SSL ligatures with MC brackets (p=0.0008) and CB (p=0.0003) showed higher biofilm formation. Conclusion: thus, brackets of MC with NiTi and NiCr wires showed lower biofilm formation, regardless of the ligature and cross-sectional or gauge of the wire and, MC and CB brackets with NiCr wires and SSL ligatures were more likely to accumulate biofilms (AU)


Objetivo: neste estudo, a formação de biofilme por Candida albicans em aparelhos ortodônticos fixos foi avaliada. Material e Métodos: um total de 300 bráquetes metálicos convencionais (MC), cerâmicos (CB), autoligados (SLB), com fios de níquel-titânio (NiTi) e níquel-cromo (NiCr) e tipos de ligaduras foram organizados em trinta grupos (n=10). Bráquetes, fios e ligaduras foram unidos, esterilizados, colocados em placas de 24 poços, contaminados com suspensões padronizadas de C. albicans (107 células/mL) e incubados a 37°C por 48 h para a formação de biofilmes. Os biofilmes formados foram rompidos por meio de um homogeneizador ultrassônico e suspensões foram diluídas e semeadas em ágar Sabouraud-dextrose para determinar as unidades formadoras de colônias por mL. A microscopia eletrônica de varredura foi realizada antes e após a formação do biofilme. Resultados: foi observada menor formação de biofilme no grupo MC em comparação aos grupos CB e SLB (p<0,0001). A formação de biofilme foi semelhante nos grupos SLB e CB (p=0,855). Em geral, os fios de seção transversal .018"x.025" apresentaram maior formação de biofilme quando associados aos três tipos de bráquetes. Os conjuntos com fios de NiCr e ligaduras SSL com bráquetes MC (p=0,0008) e CB (p=0,0003) apresentaram maior formação de biofilme. Conclusão: bráquetes MC com fios de NiTi e NiCr apresentaram menor formação de biofilme, independente da ligadura e secção transversal ou bitola do fio e, braquetes MC e CB com fios de NiCr e ligaduras SSL foram mais propensos a acumular biofilmes.(AU)


Subject(s)
Candida albicans , Microscopy, Electron, Scanning , Orthodontic Brackets , Biofilms , Orthodontic Appliances, Fixed
5.
Belo Horizonte; s.n; 2023. 64 p. ilus, graf, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1509346

ABSTRACT

A introdução da liga NiTi na endodontia proporcionou a fabricação de instrumentos com excelentes propriedades mecânicas, e uma das principais características é a possibilidade de alteração das temperaturas de transformação da liga, o qual pode possibilitar a presença de martensita em temperatura ambiente e consequentemente um efeito memória de forma. Entretanto, alguns dos sistemas comercializados atualmente possuem pouca ou nenhuma informação científica relatando suas propriedades mecânicas, características de design e métodos de fabricação. O objetivo deste trabalho foi comparar características geométricas, metalúrgicas e propriedades mecânicas (resistência à torção e flexão) de instrumentos Reciproc Blue (VDW, Munique, Alemanha), e quatro sistemas reciprocantes réplicas. Um total de 39 instrumentos de cada um dos sistemas reciprocantes, Reciproc Blue (RB), Prodesign R (PDR), V File (VF), V+ File (V+) e Univy One (UO) foram utilizados na pesquisa. O programa de Image J foi utilizado para mensuração dos diâmetros a cada milímetro da parte ativa e da área da seção transversal a 3 mm da ponta dos instrumentos. Imagens de MEV da parte ativa foram realizados para avaliar o acabamento superficial dos instrumentos. A composição atômica, fases presentes e temperaturas de transformação foram verificadas através de EDS, DRX e DSC, respectivamente. A flexibilidade foi aferida através de ensaios de dobramento até 45º conforme a especificação ISO 3630-1, e os ensaios de resistência à torção foram realizados de acordo com a especificação Nº28 ANSI/ADA. Todos os instrumentos apresentaram uma quantidade aproximadamente equiatômica de níquel e titânio. A análise qualitativa das fases cristalinas realizada através de ensaios de DRX, demonstrou a predominância de Fase R em todos os grupos, com exceção do grupo UO que apresenta uma mistura de fase R e martensita B19'. Na avaliação da área da seção, o instrumento RB obteve valores intermediários, os instrumentos PDR e V+ possuem menores valores e os instrumentos VF e UO possuem maiores valores. Observou-se grande impacto da geometria sobre as propriedades mecânicas, sendo que aqueles sistemas que apresentavam menor área que RB (PDR, V+) mostraram-se mais flexíveis e menos resistentes à torção (p<0.05), e o instrumento VF que teve maior área apresentou, como esperado, menos flexibilidade (p<0.05) e resistência torcional semelhante (p>0.05). A única exceção se deu com o sistema UO, que embora apresentasse uma maior área de seção, mostrou-se mais flexível e menos resistente à torção, provavelmente por influência da maior quantidade de martensita presente à temperatura ambiente. Nenhum dos instrumentos réplicas avaliados apresentaram características e comportamento mecânico iguais ao sistema padrão RB. Sugere-se que mais estudos devem ser realizados para a comparação do comportamento clínico destes instrumentos.


The introduction of NiTi alloy in endodontics has allowed the manufacturing of instruments with excellent mechanical properties, and one of the main characteristics is the ability to change alloy's transformation temperature, which can enable the presence of martensite at room temperature and consequently favor a shape memory effect. However, some of the currently marketed systems have limited or no scientific information regarding their mechanical properties, design characteristics, and manufacturing methods. The aim of this study was to compare the geometric characteristics, metallurgical aspects, and mechanical properties (torsional and flexural strength) of Reciproc Blue instruments (VDW, Munich, Germany) with four replica-like reciprocating systems. A total amount of 39 instruments from each reciprocating system, namely Reciproc Blue (RB), Prodesign R (PDR), V File (VF), V+ File (V+), and Univy One (UO), were used in the study. The Image J program was used to measure the diameters at every millimeter along the instruments active portion and the cross-sectional area at 3 mm from the instrument tip. SEM images of the active portion were obtained to evaluate the surface finishing of the instruments. Atomic composition, phases present, and transformation temperatures were determined through EDS, XRD, and DSC analyses, respectively. Flexibility was assessed by bending tests up to 45° according to ISO 3630-1 specifications, and torsional strength tests were performed according with ANSI/ADA Specification No. 28. All instruments exhibited an approximately equiatomic composition of nickel and titanium. Qualitative analysis of the crystalline phases using XRD tests demonstrated the predominance of the R-phase in all groups, except for the UO group, which exhibited a mixture of Rphase and B19' martensite. In terms of diameter and cross-sectional area evaluation, the RB instrument obtained intermediate values, while the PDR and V+ instruments had smaller values, and the VF and UO instruments had larger values. A significant impact of geometry on mechanical properties was observed, with systems exhibiting a smaller area than RB (PDR, V+) being more flexible and less torsion-resistant (p<0.05), and the VF instrument with a larger area showed, as expected, less flexibility (p<0.05) and similar torsional resistance (p>0.05). The only exception was the UO system, which, despite having a larger geometric configuration, exhibited greater flexibility and less torsional resistance, likely due to the higher amount of martensite present at room temperature. None of the replica-like instruments evaluated showed identical characteristics and mechanical behavior to the standard RB system. Further studies are suggested to compare the clinical performance of these instruments.


Subject(s)
Calorimetry, Differential Scanning , Endodontics , Torsion, Mechanical , Shape Memory Alloys , Mechanical Tests
6.
Braz. dent. sci ; 26(3): 1-13, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1444656

ABSTRACT

Objective: this double-blind randomized clinical trial evaluate the clinical performance of Thermo-Viscous Bulk Fill composite, Self-Adhesive Flowable composite, and Filtek Bulk Fill Composites restorations in Class I cavities over a period of 18 months. Material and Methods: twenty individuals between the ages of 30 and 45 participated in this research. Each patient should have at least three occlusal Class I carious lesions on their molars. They were dispersed at random, with n=20 teeth representing each tested material. Group I (Futurabond M+ and VisCalor Bulk Fill which heated in a viscolar dispenser at 68 °C for 30s and placed in a 4 mm thickness), Group II (Fusio Liquid Dentin self-adhesive composite which put in a thin layer (1mm increment)), and Group III (Single Bond Universal and Filtek Bulk Fill Posterior composite which applied in 4 mm thickness without heating). Using (USPHS) criteria, all restorations were assessed clinically at baseline, 6 months, 12 months, and 18 months. Using an inverse replica, the marginal seal of the investigated restorations was further evaluated under SEM. Statistical analysis was performed with Chi-square test for all USPH parameters. Results: the three tested groups recorded a one hundred percent retention rate after 18 months follow up period. Concerning marginal adaptation, marginal discoloration, anatomical form, surface texture, and color matching, there was a significant difference (p˂0.05) between the three tested groups after 12 & 18 months. After 12 & 18 months, SEM analysis of the marginal seal revealed a statistically significant difference between the three groups. Conclusion: Bulk fill resin composite restorations showed satisfactory acceptable clinical performance after 18 months of clinical service compared to self-adhesive flowable composites, and Viscalor Bulk Fill composite demonstrated excellent results with considerable changes in marginal integrity as a consequence of thermal viscous technology and increased adaptability of restorations toward cavity walls and margins (AU)


Objetivo: este ensaio clínico randomizado duplo-cego avaliou o desempenho clínico de restaurações de resina Bulk Fill Termo-Viscosa, resina autoadesiva Flowable e Filtek Bulk Fill Composites em cavidades Classe I durante um período de 18 meses. Material e Métodos: 20 indivíduos com idade entre 30 e 45 anos participaram da pesquisa. Cada paciente deveria ter pelo menos três lesões de cárie oclusais de Classe I nos molares. Eles foram divididos aleatoriamente, com n=20 dentes representando cada material testado. Grupo I (Futurabond M+ e VisCalor Bulk Fill aquecido em dispensador viscolar a 68 °C por 30s e colocado em uma espessura de 4 mm), Grupo II (resina composta autoadesiva Fusio Liquid Dentin colocada em uma camada fina (incremento de 1 mm)) e Grupo III (resina composta Single Bond Universal e Filtek Bulk Fill Posterior aplicado em espessura de 4 mm sem aquecimento). Usando os critérios (USPHS), todas as restaurações foram avaliadas clinicamente no início, 6 meses, 12 meses e 18 meses. Usando uma réplica inversa, o selamento marginal das restaurações investigadas foi avaliado em MEV. A análise estatística foi realizada com o teste qui-quadrado para todos os parâmetros USPH. Resultados: os três grupos testados registraram uma taxa de retenção de cem por cento após um período de acompanhamento de 18 meses. Em relação à adaptação marginal, descoloração marginal, forma anatômica, textura da superfície e combinação de cores, houve uma diferença significativa (p˂0,05) entre os três grupos testados após 12 e 18 meses. Após 12 e 18 meses, a análise SEM do selamento marginal revelou uma diferença estatisticamente significativa entre os três grupos. Conclusão: as restaurações de resina composta Bulk Fill apresentaram desempenho clínico aceitável satisfatório após 18 meses de atendimento clínico em comparação com as resinas compostas fluidas autoadesivas, e a resina composta Viscalor Bulk Fill demonstrou excelentes resultados com mudanças consideráveis na integridade marginal, como consequência da tecnologia viscosa térmica e maior adaptabilidade de restaurações nas paredes e margens da cavidade (AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Microscopy, Electron, Scanning , Malocclusion, Angle Class I
7.
Acta odontol. latinoam ; 35(3): 206-213, Dec. 2022. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1419947

ABSTRACT

ABSTRACT Aim: This study evaluated the influence of chitosan added to a universal adhesive system used in totaletch (TE) or self-etch (SE) mode on dentin permeability, and on the micromorphology of the adhesive layer. Materials and Method: Dentin discs were obtained from human third molars and randomly distributed according to bonding strategy (TE or SE), and to whether or not 1% chitosan (C) was added to a universal adhesive system (Single Bond Universal/3M ESPE), to create the following groups (n=10): TE, TEC, SE, and SEC. Dentin permeability was measured at baseline and after application of dentin treatments. The surface of the adhesive layer (AL) and the dentin adjacent to the AL were examined under a scanning electron microscope. Results: There were no significant differences in permeability percentage between the groups with and without C (TE and SE versus TEC and SEC) (p>0.05; Mann Whitney test). Dentin permeability was lower when the adhesive system was applied in the SE mode, regardless of the addition of C. The micromorphology of the AL surface showed irregularities, and a greater degree of porosity, when the adhesive system was applied in the SE mode, regardless of chitosan addition. There was a greater depth of penetration of the adhesives into the dentin adjacent to the AL in both the TE and TEC groups. Chitosan added to the adhesive system did not influence dentin permeability. Conclusions: The self-etch strategy led to lower dentin permeability, and to more irregularities on the surface of the adhesive layer.


RESUMO Objetivo: Este estudo avaliou a influência da quitosana adicionada a um sistema adesivo universal usado no modo total-etch (TE) ou self-etch (SE) na permeabilidade dentinária e na micromorfologia da camada adesiva. Materiais e método: Discos de dentina foram obtidos de terceiros molares humanos e distribuídos aleatoriamente de acordo com a estratégia de união (TE ou SE), e para incorporação ou não de quitosana a 1% (Q) em um sistema adesivo universal (Single Bond Universal/3M ESPE), para obter os seguintes grupos (n=10): TE, TEQ, SE e SEQ. A permeabilidade da dentina foi medida no início e após a aplicação dos tratamentos de dentina. A superfície da camada adesiva (CA) e a dentina adjacente à CA foram examinadas em microscópio eletrônico de varredura. Resultados: Não houve diferenças significativas no percentual de permeabilidade entre os grupos com e sem Q (TE e SE versus TEQ e SEQ) (p>0,05; teste de Mann Whitney). Houve um menor percentual de permeabilidade dentinária quando o sistema adesivo foi aplicado no modo SE, independentemente da incorporação de Q. A micromorfologia da superfície da CA apresentou irregularidades e maior grau de porosidade quando o sistema adesivo foi aplicado no modo SE, independentemente da adição de Q. Houve maior profundidade de penetração dos adesivos na dentina adjacente à CA nos grupos TE e TEQ. A quitosana adicionada ao sistema adesivo não influenciou a permeabilidade dentinária. Conclusões: A estratégia autocondicionante levo

8.
Rev. bras. ortop ; 57(3): 488-495, May-June 2022. tab, graf
Article in English | LILACS | ID: biblio-1388010

ABSTRACT

Abstract Objective To evaluate the systemic effect of Hancornia speciosa latex on bone neoformation and mineralization in rats. Methods For that, the latex was first collected, and its composition was analyzed. A total of 30 male Wistar rats were used, which were simultaneously submitted to two surgical procedures: extraction of an incisor and creation of a defect with 2 mm in diameter in the parietal bone. The rats were divided into two groups: systemic control (SC) systemic latex (SX) which were administered, orally and daily, 1.5 mL of water or a solution containing 50% of water and 50% of latex by gavage, respectively. After 15 days of the treatment, the animals were euthanized and their samples were collected. Results The results were statistically analyzed, and the level of significance was set at 0.05. We showed that H. speciosa latex contained calcium. The oral and daily administration of the latex for 15 days increased the contents of calcium and phosphorus in the basal bone and newly-formed bone in the mandibular alveolus of rats. Conclusion The present was a pioneer study demonstrating the potential of H. speciosa latex in increasing bone mineralization. Our results may aid in the conception and development of a natural drug.


Resumo Objetivo Avaliar o efeito sistêmico do látex de Hancornia especiosa na neoformação óssea e mineralização em ratos. Métodos Para isso, primeiro o látex foi coletado, e sua composição foi analisada. No estudo, foram utilizados 30 ratos Wistar machos submetidos simultaneamente a dois procedimentos cirúrgicos: extração de incisivo e criação de um defeito de 2 mm de diâmetro no osso parietal. Os ratos foram divididos em dois grupos: controle sistêmico (CS) e látex sistêmico (XS), aos quais foi administrado, oral e diariamente, 1,5 mL de água ou uma solução contendo 50% de água e 50% de látex por gavagem, respectivamente. Após 15 dias do tratamento, os animais foram eutanizados, e suas amostras, coletadas. Resultados Os resultados foram analisados estatisticamente, e o nível de significância foi fixado em 0,05. Mostramos que o látex de H. speciosa continha cálcio. A administração oral e diária deste látex por 15 dias aumentou o conteúdo de cálcio e fósforo de osso basal e de osso recém-formado no alvéolo mandibular de ratos. Conclusão Este foi um estudo pioneiro, que demonstrou o potencial do látex de H. speciosa no aumento da mineralização óssea. Nossos resultados podem ajudar na concepção e no desenvolvimento de uma droga natural.


Subject(s)
Animals , Rats , Complementary Therapies , Microscopy, Electron, Scanning , Durapatite , Apocynaceae/anatomy & histology
9.
São Paulo; s.n; s.n; 2022. 80 p. tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-1415544

ABSTRACT

O objetivo deste trabalho foi preparar e caracterizar nanocarreadores via auto-organização a partir da pectina de citros e lisozima para o encapsulamento da ß-lactose. Foram estudadas três condições de interação entre os biopolímeros variando a razão molar pectina/lisozima (3:1, 2:1, 1:1, 1:2 e 1:3), o pH e o tempo de aquecimento. A confirmação da interação foi determinada por espectroscopia no infravermelho por transformada de Fourier (FTIR) e por calorimetria de varredura diferencial (DSC). Os espectros de infravermelho evidenciaram que ligações de hidrogênio foram as principais forças envolvidas na formação dos nanocarreadores e sugeriram a ausência de ß-lactose livre na superfície das nanopartículas. Os termogramas evidenciaram que as nanopartículas formadas na presença de ß-lactose têm maior estabilidade térmica do que as nanopartículas sem ß-lactose. Para ambas as formulações estudadas, na presença e na ausência de ß-lactose, a formação das nanopartículas ocorreu entre os valores de pKa e ponto isoelétrico (pI) da pectina e lisozima, respectivamente, sendo a melhor razão de interação pectina/lisozima 1:2, em pH 10, a 80 ºC por 30 min. As nanopartículas foram formadas via auto-organização e todos as partículas apresentaram distribuição de tamanho homogênea, formato esférico, diâmetro inferior a 100 nm e carga superficial negativa. A morfologia e o tamanho das partículas pouco alteraram com a incorporação da -lactose. A eficiência de encapsulação (EE) da ß-lactose foi superior a 96% para as concentrações estudadas. Ensaios preliminares in vitro, em células epiteliais de câncer de cólon (HCT-116), evidenciaram que as nanopartículas formadas são capazes de adentrar no meio intracelular, possivelmente, por via endocitose


This work aimed to prepare and characterize nanocarriers via self-assembly using citrus pectin and lysozyme for ß-lactose encapsulation. Three interaction conditions between the biopolymers were studied, varying the pectin/lysozyme molar ratio (3:1, 2:1, 1:1, 1:2 and 1:3), pH and heating time. Fourier transform infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC) determined the interaction's confirmation. The infrared spectra showed that hydrogen bonds were the main forces involved in the formation of nanocarriers and suggested the absence of free ß-lactose on the surface of the nanoparticles. The thermograms showed that nanoparticles formed in the presence of ß-lactose have greater thermal stability than nanoparticles without ß-lactose. For both formulations studied, in the presence and absence of lactose, the formation of nanoparticles occurred between the pKa and isoelectric point (pI) values of pectin and lysozyme, respectively, with the best pectin/lysozyme interaction molar ratio 1:2, at pH 10, at 80 °C for 30 min. Nanoparticles were formed via self-assembly, and all particles presented homogeneous size distribution, spherical shape, diameter less than 100 nm, and negative surface charge. The morphology and size of the particles changed little with the incorporation of ß-lactose. The encapsulation efficiency (EE) of ß-lactose was higher than 96% for the concentrations studied. Preliminary in vitro assays in colon cancer epithelial cells (HCT-116) showed that the nanoparticles formed are capable of entering the intracellular medium, possibly via endocytosis


Subject(s)
Muramidase/analysis , Pectins/analysis , Biopolymers/adverse effects , Calorimetry , Calorimetry, Differential Scanning/methods , Spectroscopy, Fourier Transform Infrared/methods , Colonic Neoplasms , Nanoparticles , Hydrogen-Ion Concentration , Lactose
10.
Rev. Esc. Enferm. USP ; 56: e20210552, 2022. graf
Article in English, Portuguese | LILACS, BDENF | ID: biblio-1365410

ABSTRACT

ABSTRACT Objective: To analyze the microbiological and microstructural part of indwelling urinary catheters and their association with urinary tract infection prevention. Method: This is a cross-sectional study, from June to December 2020, in which 42 indwelling urinary catheter tips and sterile urine samples were collected for analysis of crystals in optical microscopy and biofilms in scanning electron microscopy. Culture analysis and specification of the type of bacteria were performed. Results: It was found that 35.71% of the samples had mature biofilm adhered to the catheter tip. Biofilms of Proteus mirabilis, Enterococcus faecalis, Staphylococcus epidermidis, Enterococcus faecium and Enterobacter cloacae stood out. The presence of magnesium-ammonium-phosphate crystal was associated with the presence of urinary tract infection and with Proteus mirabilis. There was a significant association (p = 0.001) between the use of prophylactic antibiotics versus urine culture >105 CFU/mL. Conclusion: The analyzes contributed to clinical practice, as it reinforces the development of effective and monitored strategies on cultures and urinary tract infection prevention associated with indwelling urinary catheters.


RESUMEN Objetivo: Analizar la parte microbiológica y microestructural de los catéteres urinarios permanentes y su asociación con la prevención de la infección del tracto urinario. Método: Transversal, de junio a diciembre de 2020, en el que se recolectaron 42 puntas de sonda urinaria permanente y muestras de orina estéril para análisis de cristales en microscopía óptica y biopelículas en microscopía electrónica de barrido. Se realizaron análisis de cultivo y especificación del tipo de bacteria. Resultados: Se encontró que el 35,71% de las muestras presentaban biopelícula madura adherida a la punta del catéter. Se destacaron las biopelículas de Proteus mirabilis, Enterococcus faecalis, Staphylococcus epidermidis, Enterococcus faecium y Enterobacter cloacae. La presencia de cristales de fosfato de magnesio-amonio se asoció con la presencia de infección del tracto urinario y con Proteus mirabilis. Hubo una asociación significativa (p = 0,001) entre el uso de antibióticos profilácticos versus urocultivo >105 UFC/mL. Conclusión: Los análisis contribuyeron a la práctica clínica, ya que refuerzan el desarrollo de estrategias efectivas y monitoreadas sobre cultivos y prevención de la infección del tracto urinario asociada a los catéteres urinarios permanentes.


RESUMO Objetivo: Analisar a parte microbiológica e microestrutural dos cateteres vesicais de demora e sua associação com a prevenção de infecção do trato urinário. Método: Transversal, entre junho e dezembro de 2020, em que foram coletadas 42 pontas cateteres vesicais de demora e amostras de urina estéril para análise de cristais em microscopia óptica e de biofilmes em microscopia eletrônica de varredura. Fez-se analise de cultura e especificação do tipo de bactérias. Resultados: Verificou-se que 35,71% das amostras apresentaram o biofilme maduro aderido à ponta do cateter. Destacaram-se biofilmes de Proteus mirabilis, Enterococcus faecalis, Staphylococcus epidermidis, Enterococcus faecium e Enterobacter cloacae. A presença do cristal magnésio-amônio-fosfato foi associada à presença de infecção do trato urinário e ao Proteus mirabilis. Verificou-se associação significativa (p = 0,001) entre o uso de antibiótico profilático versus a urocultura >105 UFC/mL. Conclusão: As análises contribuíram para a prática clínica, pois reforçam a elaboração de estratégias efetivas e monitoradas sobre culturas e prevenção de infecção do trato urinário associada ao cateter vesical de demora.


Subject(s)
Urinary Tract Infections , Urinary Catheters , Microscopy, Electron, Scanning , Public Health , Public Health Surveillance
11.
Natal; s.n; 29 dez. 2021. 93 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1532968

ABSTRACT

Introdução: Os fios Copper Ni-Ti (CuNiTi) possuem indicações de uso clínico específicas, permanecendo no ambiente bucal por um longo período. Por esse motivo suas características mecânicas, termodinâmicas e estruturais devem ser preservadas durante todo o período de uso. Objetivos: Investigar se ocorrem alterações no comportamento mecânico, termodinâmico, estrutura e composição química superficial em fios CuNiTi 35°C submetidos ao envelhecimento in vivo (uso clínico) e in vitro (termociclagem), evidenciando as possíveis diferenças entre os métodos de envelhecimento. Material e Métodos: A amostra total foi constituída de 30 arcos pré-contornados 0.016", termodinâmicos com adição de cobre, e temperatura austenítica final (Af) de 35°C, da marca Ormco®. As análises destes fios resultaram em dois capítulos. Para o experimento clínico, 10 unidades de fios foram instaladas em 05 pacientes e permaneceram em meio bucal durante 30, 60 e 90 dias, e 05 fios foram analisados como recebidos (CR). A cada período, um hemiarco completo mais 1/3 (um terço) do hemiarco inferior direito foi retirado para análises. Para o experimento in vitro os 15 fios restantes foram submetidos à termociclagem para simulação do envelhecimento em ambiente oral durante 30 (600 ciclos), 60 (1200 ciclos) e 90 dias (1800 ciclos) com variação de temperatura entre 5°C e 55°C, com banhos de 90 segundos em cada temperatura, e transição de 15 segundos entre os banhos. Após cada período de envelhecimento in vivo e in vitro, os fios foram submetidos a um teste de padronização das suas dimensões através da medição dos diâmetros com paquímetro, Microscopia Eletrônica de Varredura (MEV), Espectrometria por Raios X Fluorescentes (FRX), ensaios de tração uniaxial e ensaio de Varredura Diferencial de Calorimetria (DSC). Resultados: No capítulo 1 a comparação entre os fios CR e os envelhecidos revelou que não houve diferença significativa entre os diâmetros das amostras, das forças obtidas ou mesmo das temperaturas Af, independentemente do tempo de permanência em boca. Foram encontrados predominantemente Ni, Ti, Cu e Al nas amostras, além de outros elementos químicos em concentrações variadas. No capítulo 2 não houve diferença significativa entre os diâmetros das amostras, das forças obtidas ou mesmo das temperaturas Af entre as amostras, independentemente do tempo ou do método de envelhecimento. Conclusão: As análises laboratoriais dos fios envelhecidos in vivo e in vitro foram comparadas, evidenciando que as características mecânicas, termodinâmicas e químicas dos fios permanecem estáveis mesmo até 90 dias de uso clínico ou 1800 ciclos de termociclagem. O método de envelhecimento in vitro se mostra uma alternativa viável para a análise destes parâmetros, em substituição aos métodos in vivo (AU).


Introduction: Copper Ni-Ti wires (CuNiTi) have specific indications for clinical use, remaining in the oral environment for a long period. For this reason, their mechanical, thermodynamic and structural characteristics must be preserved throughout the period of use of these materials. Objectives: To investigate whether there are changes in the mechanical, thermodynamic, structure and surface chemical composition of CuNiTi 35°C wires subjected to in vivo aging (clinical use) and in vitro (thermocycling), highlighting the possible differences between the aging methods. Material and Methods: The total sample was obtained from 30 pre-contoured Ormco® 0.016 thermodynamic archwires with copper addition and austenitic final temperature (Af) of 35°C. The analysis of these archwires resulted in two articles. For the clinical experiment, 10 units of wires were installed in 05 patients and remained in the oral environment for 30, 60 and 90 days, and 05 wires were analyzed as received. At each period, a complete hemiarch plus 1/3 of the right lower hemiarch was removed for analysis. For the in vitro experiment, the 15 remaining wires underwent thermocycling to simulate the aging of the oral environment for 30 (600 cycles), 60 (1200 cycles) and 90 days (1800 cycles) with a temperature range between 5°C and 55°C, with 90 second baths at each temperature, and 15 second transition between baths. After each in vivo and in vitro aging period, the wires underwent to a standardization test of their dimensions, by defining the diameters with a caliper, Scanning Electron Microscopy (SEM), Fluorescent X-Ray Spectrometry (FRX), tests of Uniaxial traction and Differential Scanning Calorimetry (DSC) test. Results: In chapter 1, the comparison between CR and aged wires revealed that there was no significant difference between the sample diameters, the forces obtained or even the temperatures Af, regardless the time spent in the mouth. Predominantly Ni, Ti, Cu and Al were found in the samples, in addition to other chemical elements in different concentrations. In chapter 2 there was no significant difference between the diameters of the samples, the forces obtained or even the temperatures Af between the samples, regardless of time or aging method. Conclusion: The comparison of the laboratoral analyzes of the archwires aged in vivo and in vitro showed that the mechanical, thermodynamic and the surface chemical characteristics were stable, even up to 90 days of clinical use or 1800 thermocycling cycles. The in vitro aging method is a viable alternative for the analysis of these parameters, replacing the in vivo methods (AU).


Subject(s)
Orthodontic Wires , Orthodontics , Spectrometry, X-Ray Emission/instrumentation , Smart Materials , Calorimetry, Differential Scanning , Microscopy, Electron, Scanning/instrumentation
12.
Rev. Ciênc. Plur ; 7(2): 47-60, maio 2021. ilus, tab
Article in Portuguese | BBO, LILACS | ID: biblio-1282724

ABSTRACT

Introdução:As atuaisresinas Bulk-Fill apresentamcomovantagens e propriedades: menor tempo clínico, baixa contração de polimerização, maior translucidez, entre outros. Objetivo:Avaliar a topografia superficial de restaurações com diferentes tipos de resina composta antes e após submetê-las a diferentes sistemas de acabamento e polimento. Metodologia:Confecção de100 corpos de prova, sendo 50 de cada composto resinoso, apresentando cinco grupos (n=10) sorteados de forma aleatória, de acordo com o sistema de acabamento e polimento empregado. Foram utilizadas as resinas Filtek Z350 XT e a Bulk Fill Filtek One Bulk Fill e os sistemas de acabamento e polimento: Discos de Lixa Sof-Lex Pop On Kit;Discos Diamantado Espiral Sof-Lex; Ponta Enhance e Broca Carbide Multilaminada nº 0283F, que foram comparados com superfície deixada pela Tira de Poliester (Controle Negativo). Após 7 dias de armazenamento em água destilada, os corpos de provaforam submetidos aoMicroscópio Eletrônico de Varredura.Resultados:Os corpos de provada resina Bulk Fill tiveram como melhor resultado o sistema de acabamento e polimentocom broca carbidee resultado não satisfatório com discodiamantado espiral Sof-lex, enquanto a ponta Enhance e lixa Sof-lex Pop Ontiveram resultados semelhantes. Os corpos de prova da resina Filtek Z350 XT tiveram melhor aspecto visual de lisura no grupo controle negativoe pior resultado no grupo com disco diamantado espiral Sof-lex. Conclusões:Dessa forma, o sistema que apresentou melhor resultado foi a broca Carbidena resina Bulk Fill, enquanto a Filtek Z350 XT apresentou-se melhor no grupo controle. Porém, ainda são necessáriosestudos para se chegar em um protocolo de acabamento e polimento mais eficiente (AU).


Introduction:The current Bulk-Fill resins have the following advantages and properties: less clinical time, low polymerization shrinkage, greater translucency, among others.Objective:Toevaluate the topography of restorations with different types of composite resin before and after submitting them to different finishing and polishing systems.Methodology:Manufacture of 100 specimens, 50 of each resin compound, presenting five groups (n = 10) drawn at random, according to the finishing and polishing system employed. Filtek Z350 XT resins and Bulk Fill Filtek One Bulk Fill andfinishing and polishing systems were used: Sof-Lex Pop On Kit Sanding Discs; Diamond Spiral Sof-Lex Discs; Tip Enhance and Multilaminated Carbide Drill nº 0283F, which were compared with the surface left by the Polyester Strip (Negative Control). After 7 days of storage in distilled water, the specimens were submitted to a Scanning Electron Microscope.Results:The Bulk Fill resin specimens had the best result of the finishing and polishing system with carbide drill and unsatisfactory result with Sof-lex spiral diamond disc, while the Enhance tip and Sof-lex Pop On sandpaper had similar results. The Filtek Z350 XT resin specimens had a better visual aspect of smoothness in the negative control group and a worse result in the group with Sof-lex spiral diamond wheel.Conclusions:Thus, the system that showed the best result was the Carbide drill in Bulk Fill resin, while Filtek Z350 XT was better in the control group. However, studies are still needed to arrive at a more efficient finishing and polishing protocol (AU).


Introducción:Las actuales resinas Bulk-Fill tienen las siguientes ventajas y propiedades: menor tiempo clínico, baja contracción de polimerización, mayor translucidez, entre otras.Objetivo: Evaluar la topografía de restauraciones con diferentes tipos de resina compuesta antes y después de someterlas a diferentes sistemas de acabado y pulido.Metodología: Fabricación de 100 probetas, 50 de cada resina compuesta, presentando cinco grupos (n = 10) extraídos al azar, según el sistema de acabado y pulido empleado. Se utilizaron resinas Filtek Z350 XT y Bulk Fill Filtek One Bulk Fill y sistemas de acabado y pulido: Discos de lijado Sof-Lex Pop On Kit; Discos Sof-Lex en espiral de diamante; Broca Realce de Punta y Carburo Multilaminado nº 0283F, que fueron comparadas con la superficie dejada por la Tira de Poliéster (Control Negativo). Después de 7 días de almacenamiento en agua destilada, lasmuestras se sometieron a un Las muestras de resina Bulk Fill tuvieron el mejor resultado del sistema de acabado y pulido con broca de carburo y un resultado insatisfactorio con el disco de diamante en espiral Sof-lex, mientras que la punta Enhance y el papel de lija Sof-lex Pop On tuvieron resultados similares. Las muestras de resina Filtek Z350 XT tuvieron un mejor aspecto visual de suavidad en el grupo de control negativo y un peor resultado en el grupo con disco de diamante en espiral Sof-lex.Conclusiones: Así, el sistema que mejor resultado mostró fue la broca Carbide en resina Bulk Fill, mientras que Filtek Z350 XT fue mejor en el grupo control. Sin embargo, aún se necesitan estudios para llegar a un protocolo de acabado y pulido más eficiente (AU).


Subject(s)
Surface Properties , Microscopy, Electron, Scanning/instrumentation , Composite Resins , Dental Polishing/instrumentation , In Vitro Techniques/methods , Brazil , Polymerization
13.
Eng. sanit. ambient ; 26(2): 283-290, Mar.-Apr. 2021. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1249761

ABSTRACT

RESUMO O sulfato de alumínio (SA) é amplamente utilizado como coagulante no tratamento de água de abastecimento via ciclo completo. Coagulantes alternativos estão disponíveis no mercado, dentre eles o cloreto de polialumínio (PAC). Porém, estudos comparativos entre o SA e os PACs de alta (PAC-AB) e baixa (PAC-BB) basicidade em relação à cinética de floculação ainda são escassos. Nesse sentido, o intuito deste trabalho foi comparar o uso de PAC-BB, PAC-AB e SA via coagulação, floculação e sedimentação, bem como avaliar o efeito na condutividade elétrica, na formação de lodo, na alcalinidade, no pH e na remoção de turbidez baseado na cinética de floculação e morfologia do floco formado. Os resultados indicaram aumento de 8,1% na condutividade elétrica e de 30,6 mg.L-1 na formação de lodo; não houve diferença significativa entre os coagulantes. O PAC-AB apresentou menor consumo de alcalinidade e, consequentemente, menor redução no pH. A remoção de turbidez foi estatisticamente igual entre o PAC-BB (91,8 ± 3,7%) e o PAC-AB (91,5 ± 1,1%), porém maior que no SA (82,2 ± 6,4%). Essa diferença se acentua com o aumento da velocidade crítica de sedimentação. A constante de agregação dos flocos (K A ) apresenta resultados estatisticamente iguais entre os coagulantes, e o melhor desempenho de remoção de turbidez dos PACs em relação ao SA se deve à menor constante de ruptura do floco (K B ), podendo-se inferir, portanto, que os flocos formados com o PAC-AB e o PAC-BB são mais fortes que os formados com o SA.


ABSTRACT Aluminum sulfate (AS) is widely used as a coagulant in conventional drinking water treatment facilities. Alternative coagulants are commercially available, including polyaluminium chloride (PAC). However, comparative studies between AS and PAC with high (PAC-AB) and low (PAC-BB) basicity regarding flocculation kinetics are still scarce. In this sense, the aim of this work is to compare the use of PAC-BB, PAC-AB, and AS via coagulation, flocculation, and sedimentation as well as to evaluate the effect on electrical conductivity, sludge formation, alkalinity, pH, and turbidity removal based on flocculation kinetic and floc morphology. The results indicated that the increase in electrical conductivity was 8.1% and the sludge formation was 30.6 mg.L-1, and that there was no significant difference between coagulants. PAC-AB presented the lowest alkalinity consumption and, consequently, the lowest pH reduction. Turbidity removal was statistically equal between PAC-BB (91.8 ± 3.7%) and PAC-AB (91.5 ± 1.1%), but higher than in AS (82.2 ± 6.4%). This difference is accentuated with the increase in critical settling velocity. The floc aggregation constant (K A ) is statistically equal among the coagulants, and the better turbidity removal performance of the PACs in relation to the AS is due to the lower floc breaking constant (K B ) and may, therefore, infer that the flocs formed with PAC-AB and PAC-BB are stronger than those formed with SA.

14.
Braz. dent. sci ; 24(4, suppl 1): 1-7, 2021. ilus
Article in English | LILACS, BBO | ID: biblio-1352596

ABSTRACT

Objetivo: Este estudo in vitro objetivou caracterizar o teor de minerais e a morfologia das partículas de um dentifrício fluoretado contendo tecnologia REFIX e o teor de minerais e a morfologia da superfície do esmalte tratada com este produto. Material e Métodos: Blocos de esmalte bovino (n=5) foram obtidos (4×4×6 mm), desmineralizados (lesão de cárie artificial) e tratados (ciclagem de pH e escovação com dentifrício). Durante a ciclagem de pH de 7 dias (desmineralização e remineralização levaram 6 h e 18 h, respectivamente), o esmalte foi escovado por 5 min com uma escova dental elétrica antes de ser imerso em uma solução de remineralização. Avaliou-se a micromorfologia e os níveis elementares (% em peso) dos íons presentes no dentifrício e na camada formada sobre o esmalte após o tratamento. A morfologia da superfície foi avaliada por meio de microscopia eletrônica de varredura (MEV). As análises elementares foram realizadas usando um espectrômetro de energia dispersiva de raios-X (EDS). Resultados: A análise por MEV do dentifrício demonstrou uma distribuição de tamanho uniforme de partículas de forma regular que foram organizados esparsamente em "nanoclusters". A análise elementar da formulação do dentifrício demonstrou a presença de Si (silício), Na (sódio), P (fósforo) e F (flúor), entre outros. Observou-se também uma camada mineral na superfície de esmalte com espessura uniforme consistente em torno de 14 µm. Conclusão: De acordo com os resultados, conclui-se que a tecnologia REFIX modifica a superfície e subsuperfície da estrutura do esmalte, formando uma camada mineral rica em silício. (AU)


Objective: This in vitro study aimed at characterizing the mineral content and filler particle morphology of a fluoridated toothpaste containing REFIX technology and the mineral content and the morphology of the enamel surface treated with this product. Material and Methods: Bovine enamel blocks (n=5) were obtained (4×4×6 mm), demineralized (artificial caries lesion), and treated (pH cycling and brushing with the toothpaste). During the pH cycling, which lasted for 7 days (demineralization and remineralization took 6 h and 18 h, respectively), the enamel was brushed for 5 min using an electric toothbrush before being immersed in a remineralization solution. We evaluated the micromorphology and elemental levels (wt%) of ions present in the toothpaste and on the layer formed over the enamel following the treatment. The surface morphology was assessed using scanning electron microscopy (SEM). The elemental analyses were performed using an energy-dispersive X-ray spectrometer (EDS). Results: Scanning electron micrographs of the toothpaste demonstrated a uniform size distribution of regular-shaped fillers sparsely organized in nanoclusters. Elemental analysis of the toothpaste's formulation demonstrated the presence of Si (silicon), Na (sodium), P (phosphorus), and F (fluorine), among others. We also detected a mineral layer that had formed on the treated enamel surface; the layer had a consistent uniform thickness of ~14 µm. Conclusion: Based on the results, it can be stated that REFIX technology modifies the surface and subsurface of the enamel structure, forming a Si-rich mineral layer. (AU)


Subject(s)
Tooth Remineralization , Microscopy, Electron, Scanning , Dental Enamel , Dentifrices
15.
Braz. dent. sci ; 24(3): 1-7, 2021. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1281904

ABSTRACT

Objective: The aim of the study was to fabricate and morphologically characterize ultrafine Polyetherimide fibers (PEI) associated with Polymethylmethacrylate (PMMA) ­ PP (group formed by the association of PEI with PMMA), produced by the electrospinning process. Material and Methods: A solution of PEI (0.562 g) + PMMA (0.377 g) dissolved in 2.5 mL of chloroform, 0.85 mL of Dimethylformamide (DMF) and 0.85 mL of 1.1.2.2 Tetrachloroethane (TCE) was prepared. For the electrospinning process, different continuous voltages (10 to 18 kV) and two different distances (8 and 12 cm) between the needle tip and the collecting apparatus were used, giving rise to 6 distinct groups of ultrafine fibers (PP 1 to 6) that were observed in Scanning Electron Microscopy to check for defects and calculate the average diameter of the fibers. Results: The best parameter, the parameter that was most effective for the production of fibers, observed was subjected to Energy Dispersion X-ray Spectroscopy (EDS), X-ray Diffraction (XRD) and Contact Angle Analysis tests. The data were analyzed using the ANOVA and Tukey test (p <0.05). From the comparative analysis of the pre-established parameters, the pattern of PP4 ultrafine fibers was shown to be more effective. Conclusion: The PP4 standard (13 kV ­ 12 cm) had an average diameter of 0.37 µm. An adequate parameter to electrospinning was able to produce ultrafine fibers of PMMA/PEI (AU)


Introdução: O objetivo do estudo foi sintetizar e caracterizar morfologicamente fibras ultrafinas de Polieterimida (PEI) associadas ao Polimetilmetacrilato (PMMA) - PP (grupo formado pela associação de PEI com PMMA), produzidas pelo processo de eletrofiação. Material e Métodos: Foi preparada uma solução de PEI (0,562 g) + PMMA (0,377 g) dissolvido em 2,5 mL de clorofórmio, 0,85 mL de Dimetilformamida (DMF) e 0,85 mL de 1.1.2.2 Tetracloroetano (TCE). Para o processo de eletrofiação, foram utilizadas diferentes tensões contínuas (10 a 18 kV) e duas distâncias diferentes (8 e 12 cm) entre a ponta da agulha e o aparelho coletor, dando origem a 6 grupos distintos de fibras ultrafinas (PP 1 a 6) que foram observados em Microscopia Eletrônica de Varredura para verificar defeitos e calcular o diâmetro médio das fibras. Resultados: O melhor parâmetro, o parâmetro mais eficaz para a produção de fibras, observado foi submetido aos testes de Espectroscopia de Dispersão de Energia (EDS), Difração de Raios X (DRX) e Análise do Ângulo de Contato. Os dados foram analisados pela ANOVA e teste de Tukey (p <0,05). A partir da análise comparativa dos parâmetros pré-estabelecidos, o padrão das fibras ultrafinas PP4 mostrou-se mais eficaz. Conclusão: O padrão PP4 (13 kV - 12 cm) apresentou diâmetro médio de 0,37 µm. Um parâmetro adequado para eletrofiação foi capaz de produzir fibras ultrafinas de PMMA / PEI. (AU)


Subject(s)
Microscopy, Electron, Scanning , Polymethyl Methacrylate , Spectroscopy, Electron Energy-Loss
16.
Rev. Cient. CRO-RJ (Online) ; 5(3): 35-41, Dec. 2020.
Article in English | LILACS, BBO | ID: biblio-1342930

ABSTRACT

Introdução: o controle da qualidade no processo de fabricação dos instrumentos endodônticos é importante uma vez que defeitos e falhas superficiais podem comprometer o preparo dos canais. Objetivo: avaliar a presença de defeitos e falhas do processo de fabricação na superfície de instrumentos Reciproc (R25), Reciproc Blue (RB25) e XP-endo shaper (XP), por meio de microscopia eletrônica de varredura (MEV). Materiais e Métodos: Ao total, foram avaliados 60 instrumentos de níquel titânio, sendo 20 por grupo: R25, RB25 e XP, em três regiões: 0mm (ponta do instrumento), 4mm e 7mm da ponta, no MEV, com aumento de 100x. As imagens foram avaliadas quanto ao número de falhas de fabricação (bordo irregular, ranhura, microcavidade e rebarba) e por um sistema de escores de 1 a 4, sendo 1, nenhuma área com defeito e 4, mais de cinco áreas com defeitos na superfície. Os dados foram submetidos à análise estatística utilizando o teste de Dunn (p<0,05). Resultados: Sobre a análise por regiões, foram identificadas diferenças significativas em grande parte dos instrumentos. Comparando os diferentes instrumentos, não foi observada diferença significativa para microcavidade (p=0,76), bordo irregular (p=0,98) e rebarba (p=0,40). O instrumento R25 mostrou maior número de ranhuras em comparação aos demais (p=0,0000*). RB25 mostrou maiores valores de escores que os instrumentos R25 (p= 0,0002) eXP (p=0,01). Conclusão: Todos os instrumentos avaliados apresentaram defeitos/falhas superficiais do processo de fabricação.


Introduction: The quality control of endodontic instruments is extremely importantsince defects and failures on their surface, during their manufacturing process, can compromise the preparation of root canal. Objective: this study evaluated the presence of defects and failures in the manufacturing process on the surface of Reciproc (R25), Reciproc Blue (RB25) and XP endo-shaper (XP) instruments by means of scanning electron microscopy (SEM). Materials and Methods: In total, sixty nickel titanium instruments (n=20): R25, RB25 and XP were evaluated in the scanning electron microscope in three regions: 0mm (tip of the instrument), 4mmand 7mm of the tip, with a magnification of 100x. The images were evaluated in relation to the number of manufacturing faults (irregular border, groove, microcavity and burr) and by a system of scores, from 1 to 4, where 1 is no defective area and 4, more than five areas with defects on the surface. The data were submitted to statistical analysis using Kruskal-Wallis and Mann-Whitney tests (p<0.05). Results: Regarding the analysis by regions, significant differences were identified in most of the instruments. Comparing the different instruments, no significant difference was observed for microcavity (p=0.76), irregular border (p=0.98) and burr (p=0.40). The R25 instrument showed a greater number of grooves compared to the others (p=0.0000*). RB25 showed higher scores than the R25(p=0.0002) and XP (p=0.01) instruments. Conclusion: All evaluated instruments showed defects/failures in the manufacturing process.Introduction: The quality control of endodontic instruments is extremely importantsince defects and failures on their surface, during their manufacturing process, can compromise the preparation of root canal. Objective: this study evaluated the presence of defects and failures in the manufacturing process on the surface of Reciproc (R25), Reciproc Blue (RB25) and XP endo-shaper (XP) instruments by means of scanning electron microscopy (SEM). Materials and Methods: In total, sixty nickel titanium instruments (n=20): R25, RB25 and XP were evaluated in the scanning electron microscope in three regions: 0mm (tip of the instrument), 4mmand 7mm of the tip, with a magnification of 100x. The images were evaluated in relation to the number of manufacturing faults (irregular border, groove, microcavity and burr) and by a system of scores, from 1 to 4, where 1 is no defective area and 4, more than five areas with defects on the surface. The data were submitted to statistical analysis using Kruskal-Wallis and Mann-Whitney tests (p<0.05). Results: Regarding the analysis by regions, significant differences were identified in most of the instruments. Comparing the different instruments, no significant difference was observed for microcavity (p=0.76), irregular border (p=0.98) and burr (p=0.40). The R25 instrument showed a greater number of grooves compared to the others (p=0.0000*). RB25 showed higher scores than the R25(p=0.0002) and XP (p=0.01) instruments. Conclusion: All evaluated instruments showed defects/failures in the manufacturing process.


Subject(s)
Dental Instruments/standards , Endodontics/instrumentation , Microscopy, Electron, Scanning
17.
Dent. press endod ; 10(3): 69-74, Sept-Dec.2020. Tab, Ilus
Article in English | LILACS | ID: biblio-1348002

ABSTRACT

Objetivos: Avaliar três protocolos de irrigação final para remoção de detritos e material obturador de istmos simulados. Métodos: Setenta e oito pré-molares foram preparados com o sistema WaveOne Gold 45.05. Os dentes foram seccionados longitudinalmente e um istmo padronizado foi confeccionado no terço apical. Seis raízes foram utilizadas como controle negativo. Os espécimes foram randomizados em dois grupos principais (n=36). Trinta e seis raízes tiveram o istmo preenchido com detritos e as outras trinta e seis raízes foram obturadas com guta-percha e cimento endodôntico, por meio da técnica híbrida de Tagger. Cada grupo foi dividido em três subgrupos (n=12), de acordo com o protocolo de irrigação final: Easy Clean; irrigação ultrassônica passiva (PUI); e XP Clean. A ativação do NaOCl 2,5% pelo Easy Clean foi realizada em três ciclos de vinte segundos; e pelo XP Clean, por um minuto em movimento reciprocante e contínuo, respectivamente. No grupo PUI, o irrigante foi ativado em três períodos de vinte segundos. Resultados: Não foi encontrada associação entre os escores de remoção de detritos e os protocolos de irrigação (p=0,165). Foi observada associação entre os escores de remoção do material obturador e os protocolos de irrigação final (p<0,05). Conclusões: Os protocolos de irrigação final foram efetivos para a remoção de detritos, mas não para remoção de material obturador de istmos no terço apical (AU).


This study aimed to assess three final irrigation protocols on debris and filling removal from simulated irregularities. Methods: Seventy-eight mandibular premolars were prepared with WaveOne Gold system 45.05, splitted longitudinally, and a standardized groove was performed in the apical portion of the canals. Six roots served as negative control. The roots were randomly divided into two main groups (n = 36). The grooves were filled with dentin debris in thirty six roots. The others thirty-six were filled with gutta-percha and endodontic sealer using Tagger hybrid technique. Each main group was then divided into three groups (n = 12) according to the final irrigation protocol: Easy Clean, passive ultrasonic irrigation (PUI), and XP Clean. In Easy Clean 2.5% NaOCl activation was performed for 3 cycles of 20 seconds and XP Clean for one minute under reciprocating and continuous rotary motion and continuous rotary motion, respectively. In the PUI group, the irrigant was activated in three periods of 20 seconds. Results: No association was found among the scores of debris removal and the irrigation protocols (p = .165). An association was observed among the filling material removal scores and irrigation protocols (p< .05). Conclusion: Easy Clean, PUI and XP Clean were effective for dentin debris removal, but did not for filling material from artificial grooves in the apical third (AU).


Subject(s)
Bicuspid , Microscopy, Electron, Scanning , Efficacy , Lifting
18.
Rev. odontol. UNESP (Online) ; 49: e20200033, 2020. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1139420

ABSTRACT

Resumo Introdução A interface implante-pilar protético e a formação dos seus microgaps são aspectos relevantes na transferência das cargas e na resposta biológica, estando ligadas ao sucesso da reabilitação. Objetivo Avaliar microgaps na interface entre a conexão interna do implante do tipo Cone Morse e a superfície do componente protético por meio da microscopia eletrônica de varredura (MEV). Material e método Foram utilizados 20 implantes dentários de tamanho 3,75 × 11,0mm do tipo Cone Morse com seus respectivos pilares protéticos da Singular® (Singular Implants, RN, Brasil). Os munhões retos foram acoplados aos implantes com torque de 32N/cm2 e o conjunto resultante foi emergido em base de Resina Epóxi ES260, para permitir secção longitudinal da amostra. As amostras foram analisadas e os microgaps mensurados no MEV (JEOL JCM-5700, MA, USA), e posteriormente os dados foram analisados. Resultado A média e o desvio padrão dos maiores microgaps foram observados na parte apical do implante nos lados direito e esquerdo, sendo 1,44±2,68 e 1,16±1,49 μm, respectivamente. Os menores microgaps foram na parte superior do implante nos lados direito e esquerdo, sendo 0,60±0,73 e 0,66±0,67 μm, respectivamente. Contudo, no teste de Kruskal-Wallis, não houve diferença estatisticamente significativa entre as regiões dos implantes, tanto para o lado esquerdo (p=0,692) como para o direito (p=0,865). No teste de Mann-Whitney, não houve diferenças estatisticamente significativas entre os lados para as diferentes regiões dos implantes. Conclusão Mesmo com a presença de microgaps na interface implante-pilar protético, estes apresentam tamanho inferior ao que causaria problemas biológicos e mecânicos. As amostras analisadas quanto à sua compatibilidade de encaixe foram satisfatórias.


Abstract Introduction The implant-prosthetic abutment interface and the formation of its microgaps are relevant aspects in load transfer and biological response and are linked to the success of the rehabilitation. Objective To evaluate microgaps at the internal connection interface of the Cone Morse implant and the prosthetic component surface by means of scanning electron microscopy (SEM). Material and method Twenty 3.75 x 11.0 mm Cone Morse dental implants with their respective Singular® prosthetic abutments were used (Singular Implants, RN, Brazil). The straight trunnions were attached to the implants with a 32N/cm2 torque and the ES260 Epoxy Resin-based set emerged to allow longitudinal sectioning of the sample. The samples were analyzed and the microgaps measured in SEM (JEOL JCM-5700, MA, USA), and later the data were analyzed. Result The mean and standard deviation of the largest microgaps were observed in the apical part of the right and left side 1.44±2.68 and 1.16±1.49 μm, respectively. The smallest microgaps were on the upper implant right and left sides 0.60±0.73 and 0.66±0.67 μm, respectively. However, in the Kruskal-Wallis test there was no statistically significant difference between the implant regions, both for the left side (p=0.692) and right side (p=0.865). The Mann-Whitney test, there were no statistically significant differences between the sides for the different regions of the implants. Conclusion Even with the presence of microgaps in the implant-post interface, it presents a smaller size than the one presenting biological and mechanical problems. The samples analyzed for their fitting compatibility were satisfactory.


Subject(s)
Microscopy, Electron, Scanning , Statistics, Nonparametric , Dental Implantation
19.
Braz. dent. sci ; 23(3): 1-8, 2020. ilus
Article in English | BBO, LILACS | ID: biblio-1104271

ABSTRACT

Objective: The influence of four root canal filling techniques on the penetration of an endodontic sealer into dentinal tubules and the gutta percha/ sealer ratio (GP/SR) in root canals was evaluated using confocal laser scanning microscopy (CLSM). Material and Methods: Roots of the maxillary central incisors (n=40) were prepared with ProTaper Universal files up to file F5 and assigned to five groups: continuous wave condensation, lateral condensation, single cone, Thermafill®, and negative control group. After root canal filling with gutta-percha and AH26, along with the addition of 0.01% fluorescein, the roots were cut into 2-mm slices. Using CLSM, the specimens were transversely sectioned at 3, 6, and 10 mm from the apex. Results: Sealer penetration was deeper and more frequent at 10 mm than at the 6mm and 3mm for all obturation technique. Penetration was not significantly affected by obturation techniques except single master cone tecnique. Single cone technique demonstrated the lowest sealer penetration at all levels. However, sealer thickness was strongly dependent on obturation technique. Termafill® demostrated superior GP ratio followed by continuous wave condensation, lateral condensation and single cone. Conclusion: In conclusion, the single cone technique resulted in lower sealer penetration than the other techniques, which did not differ significantly from each other. However, sealer thickness was strongly dependent on obturation technique. Termafill® demostrated superior GP ratio followed by continuous wave condensation, lateral condensation and single cone. (AU)


Objetivo: A influência de quatro técnicas de obturação do canal radicular na penetração de um cimento endodôntico nos túbulos dentinários e a relação gutapercha / cimento (GP / CIM) em canais radiculares foram avaliadas por microscopia de varredura confocal a laser (MVCL). Material e Métodos: As raízes de incisivos centrais superiores (n = 40) foram preparadas com limas ProTaper Universal até a lima F5 e distribuídas em cinco grupos: condensação de onda contínua, condensação lateral, cone único, Thermafill® e grupo de controle negativo. Após o preenchimento do canal radicular com guta-percha e AH26, juntamente com a adição de 0,01% de fluoresceína, as raízes foram cortadas em fatias de 2 mm. Usando MVCL, as amostras foram seccionadas transversalmente a 3, 6 e 10 mm do ápice. Resultados: A penetração do cimento foi mais profunda e mais frequente em 10 mm do que nos 6 mm e 3 mm para todas as técnicas de obturação. A penetração não foi significativamente afetada pelas técnicas de obturação, exceto pela técnica de cone mestre único. A técnica de cone único demonstrou a menor penetração do cimento em todos os níveis. No entanto, a espessura do cimento foi fortemente dependente da técnica de obturação. O Termafill® demonstrou uma relação superior de GP, seguida por condensação de onda contínua, condensação lateral e cone único. Conclusão: Em conclusão, a técnica de cone único resultou em menor penetração do cimento do que as outras técnicas, que não diferiram significativamente uma da outra. No entanto, a espessura do cimento foi fortemente dependente da técnica de obturação. O Termafill® demonstrou uma relação superior de GP, seguida por condensação contínua das ondas, condensação lateral e cone único. (AU)


Subject(s)
Root Canal Obturation , Microscopy, Confocal , Dental Cements , Gutta-Percha
20.
Braz. dent. sci ; 23(4): 1-12, 2020. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1121881

ABSTRACT

Objective: The aim of this study was to evaluate and compare the microtensile bond strengths of four current adhesive materials that contain different monomers at deep and superficial dentin. Material and Methods: Forty non-carious human third molars (n=5) were used in the study. Specimens were divided into two main groups according to dentin thickness as superficial and deep dentin. Groups were further divided into four subgroups in terms of the adhesive systems used: Nova Compo B Plus (NCBP), Nova Compo B (NCB), Futurabond M (FB) and Clearfil S3 Bond Plus (CS3). All specimens were bonded to resin composite and stored in 37 °C water for 9-months. Teeth were sectioned into 3 x 3 mm thick beams. Microtensile bond strength test was carried out by using a universal testing device (1 mm/min). After fracture, failure types were observed using an optical microscope and the fractured dentin surfaces were observed by a scanning electron microscopy (SEM). One-way ANOVA and Tukey tests were used to compare the adhesive system in each dentin group. An unpaired T-test was used to compare the dentin thickness in each adhesive material. Results: As compared to deep dentin, superficial dentin showed higher µTBS values in groups NCBP, FB and CS, as opposed to group NCB. Only NCB revealed higher bond strength at deep dentin layers when compared to superficial dentin. In the superficial dentin group, NCBP showed the highest bond strength value while NCB showed the lowest bond strength. In the deep dentin group, while NCB showed the highest bond strength value, NCBP revealed the lowest bond strength value after 9-months storage. While 4-META and 10-MDP monomer combination (NCBP) resulted in the highest bond strength value among the adhesive systems in the superficial dentin group, the GPDMA and 4-META monomer combination (NCB) resulted in the highest bond strength in deep dentin group. Conclusions: Microtensile bond strength performance are affected by both the type of monomer in the adhesive combination and the depth of the dentin. (AU)


Objetivo: o objetivo deste estudo foi avaliar e comparar a resistência de união à microtração de quatro materiais adesivos atuais que contêm monômeros diferentes na dentina profunda e superficial. Material e Métodos: Quarenta terceiros molares humanos não cariados (n = 5) foram usados no estudo. Os espécimes foram divididos em dois grupos principais de acordo com a espessura da dentina em superficial e profunda. Os grupos foram subdivididos em quatro subgrupos quanto aos sistemas adesivos usados: Nova Compo B Plus (NCBP), Nova Compo B (NCB), Futurabond M (FB) e Clearfil S3 Bond Plus (CS3). Todos os espécimes foram aderidos à resina composta e armazenados em água a 37 ° C por 9 meses. Os dentes foram seccionados em palitos de 3 x 3 mm de espessura. O teste de microtração foi realizado com o uso de um dispositivo de teste universal (1 mm / min). Após a fratura, os tipos de falha foram observados em microscópio óptico e as superfícies de dentina fraturadas por microscopia eletrônica de varredura (MEV). Os testes ANOVA e Tukey um fator foram usados para comparar o sistema adesivo em cada grupo de dentina. Um teste T não pareado foi usado para comparar a espessura da dentina em cada material adesivo. Resultados: Em comparação com a dentina profunda, a dentina superficial apresentou maiores valores de µTBS nos grupos NCBP, FB e CS, ao contrário do grupo NCB. Apenas NCB revelou maior resistência de união na dentina profunda quando comparada à dentina superficial. No grupo de dentina superficial, NCBP apresentou o maior valor de resistência de união, enquanto NCB apresentou a menor resistência de união. No grupo de dentina profunda, enquanto NCB apresentou o valor de resistência de união mais alto, NCBP revelou o valor de resistência de união mais baixo após 9 meses de armazenamento. Enquanto a combinação de monômero 4-META e 10-MDP (NCBP) resultou no maior valor de resistência de união entre os sistemas adesivos no grupo de dentina superficial, a combinação de monômero (NCB) resultou na maior força de união no grupo de dentina profunda. Conclusões: O desempenho da resistência de união à microtração é afetado tanto pelo tipo de monômero na combinação adesiva quanto pela profundidade da dentina. (AU)


Subject(s)
Humans , Microscopy, Electron, Scanning , Dentin-Bonding Agents , Dentin , Molar
SELECTION OF CITATIONS
SEARCH DETAIL