Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Int. j. morphol ; 41(1): 164-166, feb. 2023. ilus
Article in English | LILACS | ID: biblio-1430528

ABSTRACT

SUMMARY: Clear awareness of the vascular variations is critical in surgeries, which may cause massive hemorrhage during surgical procedures. During educational dissection of a male cadaver, we encountered a combined variation of the left obturator artery and ipsilateral aberrant inferior epigastric artery. The left obturator artery originated from the external iliac artery, then coursed inward, adherent to the superior pubic ramus. The left inferior epigastric artery originated from the femoral artery, and coursed behind the femoral vein. These anatomical variations shown in one person were extremely rare. This is particularly true with regard to these variations while performing pelvic and inguinal region surgeries.


El conocimiento claro de las variaciones vasculares es fundamental en las cirugías, ya que pueden causar una hemorragia masiva durante los procedimientos quirúrgicos. Durante la disección educativa de un cadáver de sexo masculino, encontramos una variación combinada de la arteria obturatriz izquierda y la arteria epigástrica inferior ipsilateral aberrante. La arteria obturatriz izquierda se originaba en la arteria ilíaca externa, luego discurrió hacia medial, adhiriéndose a la rama púbica superior. La arteria epigástrica inferior izquierda se originaba en la arteria femoral y discurría por detrás de la vena femoral. Estas variaciones anatómicas mostradas en una sola persona son extremadamente raras. Esto es importante de conocer estas variaciones cuando se realizan cirugías de las regiones pélvica e inguinal.


Subject(s)
Humans , Male , Arteries/abnormalities , Groin/blood supply , Cadaver , Epigastric Arteries/abnormalities , Femoral Vein/abnormalities
2.
Colomb. med ; 52(2)Apr.-June 2021.
Article in English | LILACS-Express | LILACS | ID: biblio-1534261

ABSTRACT

In patients with abdominal trauma who require laparotomy, up to a quarter or a third will have a vascular injury. The venous structures mainly injured are the vena cava (29%) and the iliac veins (20%), and arterial vessels are the iliac arteries (16%) and the aorta (14%). The initial approach is performed following the ATLS principles. This manuscript aims to present the surgical approach to abdominal vascular trauma following damage control principles. The priority in a trauma laparotomy is bleeding control. Hemorrhages of intraperitoneal origin are controlled by applying pressure, clamping, packing, and retroperitoneal with selective pressure. After the temporary bleeding control is achieved, the compromised vascular structure must be identified, according to the location of the hematomas. The management of all lesions should be oriented towards the expeditious conclusion of the laparotomy, focusing efforts on the bleeding control and contamination, with a postponement of the definitive management. Their management of vascular injuries includes ligation, transient bypass, and packing of selected low-pressure vessels and bleeding surfaces. Subsequently, the unconventional closure of the abdominal cavity should be performed, preferably with negative pressure systems, to reoperate once the hemodynamic alterations and coagulopathy have been corrected to carry out the definitive management.


En pacientes con trauma de abdomen que requieren laparotomía, hasta una cuarta o tercera parte, habrán sufrido una lesión vascular. Las estructuras venosas principalmente lesionadas son la vena cava y las iliacas, y de vasos arteriales, son las iliacas y la aorta. El abordaje de este tipo de heridas vasculares se puede ser difícil en el contexto de un paciente hemodinámicamente inestable ya que requiera medidas rápidas que permita controlar la exanguinación del paciente. El objetivo de este manuscrito es presentar el abordaje del trauma vascular abdominal de acuerdo con la filosofía de cirugía de control de daños. La primera prioridad en una laparotomía por trauma es el control de la hemorragia. Las hemorragias de origen intraperitoneal se controlan con compresión, pinzamiento o empaquetamiento, y las retroperitoneales con compresión selectiva. Posterior al control transitorio de la hemorragia, se debe identificar la estructura vascular comprometida, de acuerdo con la localización de los hematomas. El manejo de las lesiones debe orientarse a la finalización expedita de la laparotomía, enfocado en el control de la hemorragia y contaminación, con aplazamiento del manejo definitivo. Lo pertinente al tratamiento de las lesiones vasculares incluyen la ligadura, derivación transitoria y el empaquetamiento de vasos seleccionados de baja presión y de superficies sangrantes. Posteriormente se debe realizar el cierre no convencional de la cavidad abdominal, preferiblemente con sistemas de presión negativa, para consecutivamente reoperar una vez corregidas las alteraciones hemodinámicas y la coagulopatía para realizar el manejo definitivo.

3.
Colomb. med ; 52(2): e4054611, Apr.-June 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1339737

ABSTRACT

Abstract Thoracic vascular trauma is associated with high mortality and is the second most common cause of death in patients with trauma following head injuries. Less than 25% of patients with a thoracic vascular injury arrive alive to the hospital and more than 50% die within the first 24 hours. Thoracic trauma with the involvement of the great vessels is a surgical challenge due to the complex and restricted anatomy of these structures and its association with adjacent organ damage. This article aims to delineate the experience obtained in the surgical management of thoracic vascular injuries via the creation of a practical algorithm that includes basic principles of damage control surgery. We have been able to show that the early application of a resuscitative median sternotomy together with a zone 1 resuscitative endovascular balloon occlusion of the aorta (REBOA) in hemodynamically unstable patients with thoracic outlet vascular injuries improves survival by providing rapid stabilization of central aortic pressure and serving as a bridge to hemorrhage control. Damage control surgery principles should also be implemented when indicated, followed by definitive repair once the correction of the lethal diamond has been achieved. To this end, we have developed a six-step management algorithm that illustrates the surgical care of patients with thoracic outlet vascular injuries according to the American Association of the Surgery of Trauma (AAST) classification.


Resumen El trauma vascular torácico está asociado con una alta mortalidad y es la segunda causa más común de muerte en pacientes con trauma después del trauma craneoencefálico. Se estima que menos del 25% de los pacientes con una lesión vascular torácica alcanzan a llegar con vida para recibir atención hospitalaria y más del 50% fallecen en las primeras 24 horas. El trauma torácico penetrante con compromiso de los grandes vasos es un problema quirúrgico dado a su severidad y la asociación con lesiones a órganos adyacentes. El objetivo de este artículo es presentar la experiencia en el manejo quirúrgico de las lesiones del opérculo torácico con la creación de un algoritmo de manejo quirúrgico en seis pasos prácticos de seguir basados en la clasificación de la AAST. que incluye los principios básicos del control de daños. La esternotomía mediana de resucitación junto con la colocación de un balón de resucitación de oclusión aortica (Resuscitative Endovascular Balloon Occlusion of the Aorta - REBOA) en zona 1 permiten un control primario de la hemorragia y mejoran la sobrevida de los pacientes con trauma del opérculo torácico e inestabilidad hemodinámica.

4.
Rev. colomb. cardiol ; 27(5): 405-413, sep.-oct. 2020. tab, graf
Article in Spanish | LILACS, COLNAL | ID: biblio-1289250

ABSTRACT

Resumen Introducción: en los procedimientos de extracción de electrodos, la vía femoral se usa cuando la vía superior ha fracasado. Objetivo: describir la incidencia, el éxito, las complicaciones y los predictores de uso de la vía femoral. Métodos: se realizó un análisis de la incidencia del uso de la vía femoral y los factores predictores en pacientes a quienes se les realizó extracción de electrodos entre noviembre de 2011 y noviembre de 2017. Resultados: se incluyeron 85 pacientes, con edad media de 62,36 ± 11,15 años. El 38,9% de los dispositivos eran marcapasos. Se extrajeron 135 electrodos, 59,3% de fijación pasiva. La mediana de tiempo desde el implante fue de 102 (60-174) meses. Se empleó la ruta femoral en el 25,9% de los procedimientos. Se obtuvo éxito clínico en el 92,9% de los pacientes. La extracción no fue exitosa en el 22,7% de los procedimientos cuando se usó la vía femoral, en comparación con el 1,6% cuando se usó la vía superior (p 0,004). La extracción no fue completa en el 36,4% de los procedimientos cuando se empleó la vía femoral en comparación con el 9,5% por vía superior (p 0,007). Los factores que predijeron el empleo de la ruta femoral fueron la presencia de electrodos de fijación pasiva [OR IC 95% 13,69 (3,06-62,5) p 0,001] y el tiempo desde el implante del electrodo [OR IC 95% por cada 10 meses 1,04 (1,00-1,09) p 0,044]. Conclusiones: se empleó la ruta femoral en el 25,9% de los procedimientos. No fue eficaz en el 22,7% de las intervenciones. Los factores que predijeron su utilización fueron la presencia de electrodos de fijación pasiva y el tiempo desde el implante del electrodo.


Abstract Introduction: The femoral route is used in electrode removal procedures when the upper route has failed. Objective: To describe the incidence, success rate, complications and predictive factors for the use of the femoral route. Methods: An analysis was performed on the incidence of use of the femoral route and the predictive factors in patients in whom electrode removal was carried out between November 2011 and November 2017. Results: The study included 85 patients with a mean age of 62.36 ± 11.5 years. Pacemakers made up 38.9% of the devices. A total of 135 electrodes, 59.3% of passive fixation, were removed. The median time since the implant was 102 (60-174) months. The femoral route was used in 25.9% of the procedures. Clinical success was achieved in 92.9% of the patients. The removal was not successful in 22.7% of the procedures when the femoral route was used, compared to 1.6% when the upper route was used (P = .004). The removal was not completed in 36.4% of the procedures when the femoral route was used, compared to 9.5% with the upper route (P = .007). The factors that predicted the use of the femoral route were the presence of passive-fixation electrodes (OR = 13.69: 95% CI; 3.06 - 62.5, P = .001), and the time since the electrodes were implanted (OR = 1.04, 95% CI; 1.00 - 1.09, P = .044, for every 10 months). Conclusions: The femoral route was employed in 25.9% of the procedures. It was not effective in 22.7% of the interventions. The factors that predicted its use were the presence of passive-fixation electrodes and the time since the electrode implant.


Subject(s)
Humans , Male , Middle Aged , Electrodes , Femoral Vein , Incidence , Equipment and Supplies
5.
Rev. méd. Hosp. José Carrasco Arteaga ; 11(1): 75-78, Marzo 2019. Ilustraciones
Article in Spanish | LILACS | ID: biblio-1016298

ABSTRACT

INTRODUCCIÓN:La embolización de cuerpos extraños intravasculares es una complicación poco frecuente; sin embargo, está asociada a alteraciones cardíacas y pulmonares en más del 50% de los casos. Actualmente se prefiere realizar el manejo utilizando técnicas de extracción por cateterismo cardíaco, esto debido a la naturaleza menos invasiva del procedimiento y a las menores tasas de mortalidad y complicaciones asociadas. A continuación se presenta un reporte de caso donde se realizó la extracción un catéter intracardiaco mediante vía percutánea. CASO CLÍNICO: Lactante de sexo masculino, de 51 días de vida, con antecedentes de prematuridad extrema y peso adecuado para edad gestacional, ingresado en el servicio de neonatología; a quien como acceso vascular central se le colocó un catéter percutáneo femoral. Tras el retiro del mismo se apreció rotura y embolización de los dos tercios distales; la evaluación radiológica evidenció catéter a nivel de cavidades cardíacas derechas. EVOLUCIÓN: Se inició antibioticoterapia por el riesgo de infección asociado. De forma exitosa se realizó la extracción del cuerpo extraño por intervencionismo percutáneo; el paciente evolucionó favorablemente, no presentó ninguna complicación. CONCLUSIÓN: La rotura y embolización del catéter es un evento poco frecuente que incrementa la morbimortalidad de los pacientes ingresados en neonatología. La extracción percutánea debe ser la primera opción por la eficacia y seguridad del procedimiento.(au)


BACKGROUND: The embolization of foreign intravascular bodies is a rare complication; however, it is associated with cardiac and pulmonary dysfunction in more than 50% of cases. Currently, it is preferred to perform the management using extraction techniques by cardiac catheterization; this is explained by the less invasive nature of the procedure and the lower mortality and complications rates. The following is a case report where an intracardiac catheter was extracted by a percutaneous procedure. CASE REPORT: Male, 52-day-old infant, with history of extreme prematurity and adequate weight for gestational age; hospitalized in the neonatology service; as central vascular access a percutaneous femoral catheter was placed. After removal, rupture and embolization of the distal two thirds were observed; the radiological evaluation showed a catheter at the level of right heart cavities. EVOLUTION: By the associated infection risk, antibiotic therapy was initiated. The foreign body was extracted successfully by percutaneous intervention; the patient presented a favorable evolution without any complications. CONCLUSIONS: The catheter rupture and embolization is a rare event that increases morbidity and mortality rates of patients admitted to neonatology. Percutaneous extraction should be the first option by the procedure efficacy and safety.(au)


Subject(s)
Humans , Male , Infant , Catheterization , Embolism , Femoral Vein , Catheters , Foreign Bodies
6.
Int. j. morphol ; 30(4): 1327-1331, dic. 2012. ilus
Article in English | LILACS | ID: lil-670145

ABSTRACT

The aim was to understand the anatomical features of the venous valve in Macaca fascicularis and to compare it with that of humans. The bilateral lower limbs (24 limbs from 12 animals) of Macaca fascicularis cadavers were dissected, and the femoral veins (FVs) were equally divided into distal, intermediate, and proximal sections. The external diameter of the FV in each section was measured. The venous valves were observed microscopically and stained with hematoxylin and eosin as well as trichrome. Data describing the human venous valve were collected from the current literature. No great saphenous veins were found among the 24 lower limbs from the Macaca fascicularis cadavers. The external diameters of the FVs in the distal, intermediate, and proximal sections were 3.53 ± 0.37 mm, 3.42 ± 0.55 mm, and 3.37 ± 0.54 mm, respectively. In most cases, there was one venous bivalve located in the FV approximately 0-2.71 mm below the junction of the FV and the deep femoral vein. Endothelium covered the luminal and sinusal surfaces of the leaflets. Abundant collagen fibers were found under the endothelial cells beneath the luminal surface of the leaflets. An elastin fiber network was located under the sinus endothelial surface. Smooth muscle cells in the FV extend to the edge of the valve. The venous valve of Macaca fascicularis is similar to that of humans, both morphologically and histologically. However, there is only one venous bivalve and no great saphenous vein in Macaca fascicularis.


El objetivo fue comprender las características anatómicas de la válvula venosa en Macaca fascicularis y compararla con la de los humanos. Fueron disecados bilateralmente los miembros pélvicos (24 miembros de 12 animales) de cadáveres de Macaca fascicularis; las venas femorales (VF) fueron divididas en secciones distal, media y proximal. Se midió el diámetro externo de las VFs en cada sección. Las válvulas venosas se observaron microscópicamente y se tiñeron con H-E y tricrómico. Los datos para describir la válvula venosa humana se obtuvieron desde la literatura. No se encontraron venas safenas magnas entre los 24 miembros inferiores. Los diámetros externos de las VFs en las secciones distal, media y proximal fueron 3,53±0,37 mm, 3,42 mm±0,55, y 3,37±0,54 mm, respectivamente. En la mayoría de los casos, hubo vena bivalva situada aproximadamente 0-2,71 mm debajo de la unión de la VF y la vena femoral profunda. El endotelio cubrió las superficies luminal y sinusal. Se observaron abundantes fibras de colágeno en las células endoteliales bajo la superficie luminal de las válvulas. Una red de fibras de elastina se encontró bajo la superficie del seno endotelial. Las células musculares lisas en las VFs se extiendían hasta el margen de la válvula. La válvula venosa del Macaca fascicularis es similar a la de los seres humanos, morfológica e histológicamente. Sin embargo, sólo hubo una vena bivalvular, y no se observaron venas safenas en Macaca fascicularis.


Subject(s)
Animals , Venous Valves/anatomy & histology , Femoral Vein/anatomy & histology , Macaca fascicularis/anatomy & histology
7.
VozAndes ; 21(1): 27-28, 2010.
Article in Spanish | LILACS | ID: biblio-1025517

ABSTRACT

Reportamos el caso de una paciente con bloqueo aurículoventricular completo, con un marcapaso epicárdico infectado y venas torácicas inabordables, en quien se realizó exitosamente el implante transfemoral de un marcapaso unicameral VVIR. Revisamos la literatura con algunas series en las que se demuestra la factibilidad y seguridad de la técnica.


We report the case of a patient with complete atrioventricular block, with an infected epicardial pacemaker and intractable thoracic veins, in which it was performed successfully the transfemoral implant of a unicameral pacemaker VVIR. We check literature with some series in which the feasibility and safety of The technique.


Subject(s)
Humans , Pacemaker, Artificial , Femoral Vein , Heart Block , Atrioventricular Block , Contraindications
SELECTION OF CITATIONS
SEARCH DETAIL