Chinese Journal of Medical Instrumentation ; (6): 467-470, 2020.
Article in Chinese | WPRIM | ID: wpr-942764

ABSTRACT

This paper is a summary of the three types of faults that have occurred in the recent years in the Carestream DR7500:hardware failure, software failure, and communication failure. The specific cases of three types of faults are introduced in a case-by-case basis.


Subject(s)
Equipment Failure , Maintenance , Radiographic Image Enhancement
2.
Chinese Journal of Medical Instrumentation ; (6): 75-78, 2019.
Article in Chinese | WPRIM | ID: wpr-772561

ABSTRACT

OBJECTIVE@#To analyze the causes leading to hemodialysis machine & accessories faults and to give preventive measures.@*METHODS@#The causes of 34 hemodialysis machine & accessories faults during hemodialysis process were studied through retrospective analysis from January 2017 to June 2018 in our hemodialysis center.@*RESULTS@#The main factors were hemodialysis machine failure, water & electricity failure, dialytic pipeline failure, unstandardized using. The members in hemodialysis center benefited a lot from the faults, The engineers strengthened the preventive repair & quality control of hemodialysis machine, the monitoring of water & electricity. The nursing staff strengthened the quality control of the pipeline and the study of the principle & standard use of hemodialysis machine.@*CONCLUSIONS@#The study on hemodialysis machine & accessories faults improved the professional level of nurses & engineers, helped them to solve and prevent faults more precisely and improved the quality of hemodialysis.


Subject(s)
Quality Control , Renal Dialysis , Retrospective Studies
3.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1419-1425, nov.-dez. 2017. ilus
Article in English | LILACS, VETINDEX | ID: biblio-909829

ABSTRACT

Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes.(AU)


A radioterapia é uma modalidade que tem apresentando grandes avanços dentro da medicina veterinária pelo mundo. No Brasil, essa opção terapêutica é pouco realizada. O sucesso dessa modalidade depende de vários fatores, entre eles, o uso de acessórios adequados para a proteção e imobilização dos pacientes. Para a imobilização dos pequenos animais durante o tratamento, além da sedação e da anestesia, são utilizados acessórios imobilizadores semelhantes aos usados na radioterapia humana. Devido a isso, este trabalho teve como objetivo de apresentar propostas de acessórios de imobilização adaptados ao posicionamento de pequenos animais para o uso nos planejamentos radioterápicos. Para a sua realização, foram confeccionados acessórios e testados em um animal vivo simulando um planejamento radioterápico, os quais mostraram ser favoráveis ao uso nos posicionamento de pequenos animais submetidos à radioterapia e para sua implementação.(AU)


Subject(s)
Animals , Female , Dogs , Equipment and Supplies/veterinary , Immobilization/instrumentation , Immobilization/veterinary , Radiotherapy/veterinary , Patient Positioning/veterinary
4.
Chinese Traditional and Herbal Drugs ; (24): 681-685, 2017.
Article in Chinese | WPRIM | ID: wpr-852971

ABSTRACT

Objective: To utilize powder physical characteristics, optimize prescription of dry granulation process of Xiaochuan Granules (XG). Methods: Filtering of granulation prescription was guided by investigating of powder material physical characteristics such as angle repose, compression degree, water content, etc; With one time forming rate, friability and quality score of granulation process as indexes, L9(34) orthogonal test which based on the evaluation method of information entropy was used to optimize the process parameters in XG dry granulation. Results: The optimum accessory is CD, optimum dry granulation technology parameters was as follows: roll wheel pressure of 7 MPa, roll wheel speed of 10 r/min, and feed speed of 18 r/min. Conclusion: Study of physical property of preparation materials could guide filtering prescription of dry granulation preparation; The prepared granules have high forming rate with moderate hardness and good flowability, and this optimized dry granulation technology is stable and reasonable.

5.
China Journal of Endoscopy ; (12): 98-102, 2017.
Article in Chinese | WPRIM | ID: wpr-664268

ABSTRACT

Objective To present novel measures in endoscopic removal of foreign bodies in the upper gastrointestinal tract. Methods The clinical trial performed a retrospective analysis of emergency endoscopic management of 251 cases of foreign bodies in the upper gastrointestinal tract from January 2013 to November 2016. The patients underwent gastric endoscopic examinations under local pharyngeal anesthesia or general intravenous anesthesia. Flexible endoscopes and retrieval accessories such as rat-tooth and alligator forceps, polyp snares, polyp graspers, dormia basket, lithotripter or grasping forceps or rubber gloves were used for the endoscopic procedures. We reviewed of patients' general data (age, sex, type of foreign body), type of anaesthesia, foreign bodies' locations, type of accessory, complications, success rate. Results A total of 251 foreign bodies were definitely diagnosed through endoscopy, 248 foreign bodies were successfully removed with compatible devices according to the foreign bodies' location, nature, and size, and 3 cases failed. At the same time, 192 cases had little mucosal laceration and bleeding, and 45 cases were found to have underlying diseases. 1cases had esophageal surgery and 1cases had laryngeal surgery. 1 cases refuse to remove the foreign body because no symptoms and therapheutic risks. Conclusion Emergency endoscopic management is the foremost option for foreign bodies in the upper gastrointestinal tract, for its obvious advantages in safety, efficiency, low cost, and minimal invasion. Endoscopic intervention can also diagnose early underlying digestive diseases. Innovative measures can increase the successful rate of removing foreign bodies with gastric endoscopy.

6.
Clinical Endoscopy ; : 234-241, 2017.
Article in English | WPRIM | ID: wpr-165389

ABSTRACT

Endoscopic accessories describe an extensive variety of auxiliary instruments used for diagnostic and therapeutic endoscopy. Various endoscopic accessories have been developed over the previous few decades and are mostly used for treating neoplastic lesions, such as early gastrointestinal (GI) carcinomas and premalignant lesions. Because of extensive research on natural orifice endoluminal surgery (NOTES) in the early 2000s and recent technological developments, new devices have been developed for various advanced endoluminal therapeutic procedures. In particular, a remarkable development of endoscopic management was achieved in the field of gastroesophageal reflux disease (GERD) and obesity. In both conditions, there is treatment gap between medical and surgical therapy. A large proportion of the patients who do not respond to medical treatment and lifestyle modification, still hesitate to directly undergo surgical treatment. To bridge this gap, endoscopic management has been receiving increasing attention. In this article, I review endoscopic and/or endoluminal devices used for the treatment of GERD and obesity with proposed mechanisms of their function.


Subject(s)
Humans , Endoscopy , Gastroesophageal Reflux , Life Style , Obesity
7.
Article in English | IMSEAR | ID: sea-155346

ABSTRACT

Background & objectives: With increasing use of soft contact lenses the incidence of contact lens induced infections is also increasing. This study was aimed to assess the knowledge of new and existing contact lens users about the risk of microbial contamination associated with improper use and maintenance of contact lenses, type of microbial flora involved and their potential to cause ophthalmic infections. Methods: Four samples each from 50 participants (n=200) were collected from the lenses, lens care solutions, lens care solution bottles and lens cases along with a questionnaire regarding their lens use. The samples were inoculated onto sheep blood agar, Mac Conkey’s agar and Sabouraud’s dextrose agar. Organisms were identified using standard laboratory protocols. Results: Overall rate of microbial contamination among the total samples was 52 per cent. The most and the least contaminated samples were found to be lens cases (62%) and lens care solution (42%), respectively. The most frequently isolated contaminant was Staphylococcus aureus (21%) followed by Pseudomonas species (19.5%). Majority (64%) of the participants showed medium grade of compliance to lens cleaning practices. Rate of contamination was 100 and 93.75 per cent respectively in those participants who showed low and medium compliance to lens care practices as compared to those who had high level of compliance (43.75%) (pP<0.05). Interpretation & conclusions: Lens care practices amongst the participants were not optimum which resulted into high level contamination. Hence, creating awareness among the users about the lens care practices and regular cleaning and replacements of lens cases are required.

8.
Chinese Traditional and Herbal Drugs ; (24): 774-777, 2014.
Article in Chinese | WPRIM | ID: wpr-854646

ABSTRACT

Objective: To study the balanced release of complex components of Chuanping extract sustained-release tablets combined with different accessories. Methods: With methamphetamine, pseudoephedrine, and scopolamine as indexes, HPLC and the in vitro release test were applied to determining the accumulated release rate of the complex components in nine sustained-release Chuanping extract preparations (Q1-Q9), and to evaluating the influences of different accessories to the release behaviors of complex components in vitro. Results: The differences about dissolutions of four single modern materials in Chuanping extract sustained-release tablets Q1-Q3 were significant, and Q4 released fast. All of them were not balanced release. The differences about dissolutions of single improved Chinese materia medica (CMM) sustained-release accessories made Chuanping extract sustained-release tablets Q5 were significant, and Q6 was balanced release. The difference about dissolutions of complex improved CMM sustained release excipients made Chuanping extract sustained-release tablets Q9 was incomplete, the balanced release of Q8 was not well. The balanced-release of complex components of Q7 was well. Conclusion: Different accessories would affect the balanced release of sustained-released Chuanping extract tablet in vitro. The modern sustained-release accessories are hard to achieve the balanced release of complex components of CMM compound sustained-release preparations, but the improved traditional sustained-release accessories could be achieved well.

9.
Indian J Pathol Microbiol ; 2010 Oct-Dec; 53(4): 711-713
Article in English | IMSEAR | ID: sea-141792

ABSTRACT

Background: Nosocomial infections are on the rise worldwide and many a times they are carried by the health care personnel. Accessories used by physicians and healthcare personnel can be a potential source of nosocomial infection. Materials and Methods: We designed a survey with the aim to investigate the prevalence of microbial flora of accessories such as pens, stethoscopes, cell phones and white coat used by the physicians working in a tertiary care hospital. Observations: It was observed that 66% of the pens, 55% of the stethoscopes, 47.61% of the cell phones and 28.46% of the white coats used by the doctors were colonized with various microorganisms. Staphylococcus spp. was the predominant isolate followed by Escherichia coli. Methicillin resistance in Staphylococcus aureus was also found, which was a matter of concern. Conclusions: Awareness of appropriate hand hygiene is important in order to prevent potential transmission to patients.