Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Braz. dent. j ; 21(6): 515-519, 2010. tab
Article in English | LILACS | ID: lil-572297

ABSTRACT

This study compared vertical and passive fit of one-piece cast frameworks made with 3 different materials: commercially pure titanium (CP Ti - G1), cobalt-chromium alloy (Co-Cr - G2) and nickel-chromium-titanium alloy (Ni-Cr-Ti - G3). Fifteen frameworks were obtained simulating bars for fixed prosthesis in a model with 5 implants. The passive and vertical fit of the framework interface was measured using an optical microscope at ×30 magnification. Data were statistically analyzed by ANOVA and LSD tests (α=0.05). Mean and standard deviation values for passive fit and vertical fit were, respectively: G1 [472.49 (109.88) µm and 29.9 (13.24) µm], G2 [584.84 (120.20) µm and 27.05 (10.30) µm], and G3 [462.70 (179.18) µm and 24.95 (11.14) µm]. For vertical fit, there were no significant differences among G1, G2 and G3 (p=0.285). There were no significant differences for passive fit between G1 and G3 (p=0.844), but both differed significantly from G2 (p=0.028 and p=0.035, respectively), which showed the highest misfit values. It may be concluded that the vertical fit of frameworks was not affected by the tested materials, and that one-piece cast frameworks resulted in inadequate passive fit. The Co-Cr alloy presented the worst values for passive fit.


Este estudo tem como objetivo comparar o ajuste vertical e a passividade de infraestruturas em monobloco confeccionadas em 3 diferentes materiais: titânio comercialmente puro (Ti cp - G1), cobalto-cromo (Co-Cr - G2) e níquel-cromo-titânio (Ni-Cr-Ti - G3). Quinze infraestruturas foram obtidas simulando barras para próteses fixas em um modelo com 5 implantes. O ajuste vertical e a passividade da interface da infraestrutura foram medidos usando um microscópio óptico (30×). Os dados foram analisados estatisticamente por meio da ANOVA e teste LSD (α=0,05). A média dos valores e o desvio-padrão da passividade e do ajuste vertical estão apresentados respectivamente: Ti cp [472,49 (109,88) μm e 29,9 (13,24) μm], Co-Cr [584,84 (120,20) μm e 27,05 (10,30) μm], Ni-Cr-Ti [462,70 (179,18) μm e 24,95 (11,14) μm]. Para o desajuste vertical, não houve diferença significante entre o Ti cp e as ligas Co-Cr e Ni-Cr-Ti (p=0,285). Para passividade, não houve diferença significante entre Ti cp e Ni-Cr-Ti (p=0,844), mas ambos foram estatisticamente diferentes do Co-Cr (p=0,028 e p=0,035, respectivamente), o qual apresentou os piores resultados. Pode-se concluir que os materiais utilizados para confecção das infraestruturas não influenciaram o ajuste vertical e que infraestruturas fundidas em monobloco resultaram em inadequados ajustes passivos. A liga de Co-Cr apresentou os piores resultados para a passividade.


Subject(s)
Chromium Alloys , Dental Prosthesis Design/adverse effects , Dental Prosthesis, Implant-Supported/adverse effects , Titanium , Analysis of Variance , Cobalt , Dental Abutments , Dental Casting Technique , Dental Implants , Models, Dental , Endpoint Determination , Nickel , Prosthesis Fitting
2.
Rev. Asoc. Odontol. Argent ; 90(1): 16-20, ene.-feb. 2002. ilus
Article in Spanish | LILACS | ID: lil-304843

ABSTRACT

Fracasos de los distintos momentos de la terapéutica implantaria. 1. Fracasos durante la técnica quirúrgica: Forma y calidad no adecuada de los maxilares; falta de precisión en las perforaciones. 2. Complicaciones durante el período de cicatrización: fístulas o abscesos, desatornillado de la tapa de cierre, hilo de sutura incluido en la mucosa, fibrointegración del implante. 3. Fracasos durante la conexión de los emergentes. Técnica quirúrgica inadecuada. Carga prematura. 4. Fracasos después de la colocación de la restauración: técnica quirúrgica inadecuada, tipo de fresas, velocidad de fresado, irrigación, intermitencia; sobrecarga, pérdida ósea marginal rápida, fractura del pilar o del implante. 5. Complicaciones después de la colocación de la restauración, mala conexión del pilar protésico. 6. Otras causas de fracasos: infección quirúrgica; criterio y/o diseño protético incorrecto; retiro de un implante; conclusión


Subject(s)
Humans , Dental Implantation, Endosseous/adverse effects , Dental Prosthesis, Implant-Supported/adverse effects , Wound Healing/physiology , Bone Density/physiology , Dental Abutments , Denture, Partial, Fixed , Dental Prosthesis Design/adverse effects , Equipment Reuse , Surgical Wound Infection/complications , Osseointegration/physiology , Prosthesis Failure , Denture, Overlay/adverse effects , Treatment Outcome
3.
Acta odontol. venez ; 38(2): 41-44, 2000. ilus
Article in Spanish | LILACS | ID: lil-304773

ABSTRACT

Paciente masculino de 55 años de edad, restaurado con sobredentadura parcial removible. El examen clínico y radiográfico reveló que el diente 25 estaba parcialmente erupcionado y el 28 era una microdoncia. Se decidió mantener el diente 25 para mejorar el soporte, retención y estabilidad de la prótesis


Subject(s)
Humans , Male , Middle Aged , Tooth Abnormalities/etiology , Denture, Overlay , Denture, Partial, Removable , Tooth Abnormalities , Bicuspid , Dental Prosthesis Design/adverse effects , Tooth Eruption/physiology , Jaw, Edentulous, Partially , Molar, Third
4.
Rev. Fac. Odontol. Bauru ; 6(2): 53-65, abr.-jun. 1998. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-256199

ABSTRACT

Estudou-se em 120 indivíduos, metade dentados e os demais portadores de dentaduras completas, entre outras características, a largura do nariz em repouso e sua correlaçäo com a distância intercaninos, medida de cúspide a cúspide, em linha reta. Uma técnica de projeçäo da largura nasal (PANC) foi comparada com a técnica de projeçäo das comissuras labiais, para escolha da largura dos dentes. Analisou-se ainda a regiäo de incidência da linha intercuspídea canina sobre a papila incisiva, nos dentados. Finalmente, foram analisadas duas tabelas de modelos de dentes artificiais encontradas no comércio. Com base nos resultados, dentro das condiçöes estabelecidas, concluiu-se o seguinte: näo é adequado se estabelecer correlaçäo entre a largura do nariz em repouso e a distância intercaninos, medida de cúspide a cúspide, em linha reta; confirmou-s e o método PANC como mais adequado que o de projeçäo das comissuras labiais; existem dentados nos quais a largura dos seis dentes ântero-superiores é maior que a medida máxima dos artificiais disponíveis no mercado; a linha intercuspídea canina superior incidiu sobre a papila incisiva, no seu terço posterior, em 63,666 por cento dos dentados; há forte evidência de que, nas próteses totais superiores, os dentes foram escolhidos com largura menor que o adequado, para o sexo masculino


Subject(s)
Humans , Male , Female , Adult , Adolescent , Tooth, Artificial/classification , Tooth, Artificial/supply & distribution , Mouth, Edentulous/therapy , Dental Prosthesis Design/adverse effects , Dental Prosthesis Design/methods , Dental Prosthesis Design/standards , Denture, Complete
SELECTION OF CITATIONS
SEARCH DETAIL