Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Braz. J. Pharm. Sci. (Online) ; 53(1): e16092, 2017. tab, graf
Article in English | LILACS | ID: biblio-839463

ABSTRACT

ABSTRACT The aim of this study was to create and test a new mice 3D-voxel phantom named DM_BRA for mice and human first-estimation radiopharmaceutical dosimetry. Previously, the article reviews the state-of-art in animal model development. Images from Digimouse CT database were used in the segmentation and on the generation of the voxelized phantom. Simulations for validation of the DM_BRA model was performed at 0.015, 0.1, 0.5, 1 and 4 MeV photons with heart-source. Specific Absorbed Fractions (SAF) data were compared with literature data. The organ masses of DM_BRA correlated well with existing models based on the same dataset; however, few small organ masses hold significant variations. The SAF data in most simulated cases were statistically equal to a significant level of 0.01 to the reference data.


Subject(s)
Computer Literacy , Dosimetry/analysis , Mice/classification , Radiometry/methods
2.
Radiol. bras ; 43(6): 395-400, nov.-dez. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-571680

ABSTRACT

OBJETIVO: Comparar dados de dosimetria e fluência de fótons entre diferentes modelos de mama, discutindo as aplicações em testes de constância e estudos dosimétricos aplicados à mamografia. MATERIAIS E MÉTODOS: Foram simulados diferentes modelos homogêneos e um modelo antropomórfico de mama tipo voxel, sendo contabilizadas: a dose total absorvida no modelo, a dose absorvida pelo tecido glandular/material equivalente, e a dose absorvida e a fluência de fótons em diferentes profundidades dos modelos. Uma câmara de ionização simulada coletou o kerma de entrada na pele. As combinações alvo-filtro estudadas foram Mo-30Mo e Mo-25Rh, para diferentes potenciais aceleradores de 26 kVp até 34 kVp. RESULTADOS: A dose glandular normalizada, comparada ao modelo voxel, resultou em diferenças entre -15 por cento até -21 por cento para RMI, -10 por cento para PhantomMama e 10 por cento para os modelos Barts e Keithley. A variação dos valores da camada semirredutora entre modelos foi geralmente inferior a 10 por cento para todos os volumes sensíveis. CONCLUSÃO: Para avaliar a dose glandular normalizada e a dose glandular, em mamas médias, recomenda-se o modelo de Dance. Os modelos homogêneos devem ser utilizados para realizar testes de constância em dosimetria, mas eles não são indicados para estimar a dosimetria em pacientes reais.


OBJECTIVE: To compare data regarding dosimetry and photons fluence in different breast phantoms, discussing constancy tests and dosimetry applied to mammography. MATERIALS AND METHODS: Different homogeneous breast phantoms and one anthropomorphic voxel phantom were developed for collection of data regarding total absorbed dose in the phantom, absorbed dose in the glandular tissue material-equivalent, absorbed dose and photons fluence at different depths in the phantoms. A simulated ionization chamber collected the entrance skin kerma. Target-filter combinations (Mo-30Mo and Mo-25Rh) were studied for different accelerating potentials of 26 kVp to 34 kVp. RESULTS: As compared with the voxel phantom, the normalized glandular dose resulted in differences from -15 percent to -21 percent for RMI, -10 percent for PhantomMama, and 10 percent for the Barts and Keithley models. The half-value layer variation was generally < 10 percent for all the sensitive volumes. CONCLUSION: The phantom proposed by Dance is recommended for evaluating the glandular dose and normalized glandular dose in a standard breast. Homogeneous phantoms should be utilized for constancy tests in dosimetry, but they are not appropriate for estimating dosimetry in actual patients.


Subject(s)
Radiation Dosage , Mammography , Models, Anatomic , Radiometry , Dosimetry/analysis , Radiation Control , Technology, Radiologic
3.
Radiol. bras ; 43(1): 1-6, jan.-fev. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-542681

ABSTRACT

OBJETIVO: Avaliar a distribuição de dose em diferentes situações de braquiterapia endobrônquica de alta taxa de dose, com foco principalmente nos volumes de altas doses, e tentar definir situações de melhor ou pior distribuição de dose que possam servir de guia na prática clínica. MATERIAIS E MÉTODOS: Estudo teórico, simulando braquiterapia endobrônquica de alta taxa de dose utilizando dois cateteres, com variação da extensão de carregamento, angulação entre os cateteres, profundidade de cálculo e o intervalo entre as paradas da fonte. Com prescrição de 7,5 Gy, foram calculados os volumes englobados pelas isodoses correspondentes a 100 por cento, 150 por cento e 200 por cento da dose prescrita (V100, V150 e V200, respectivamente) e as razões V150/V100 e V200/V100. RESULTADOS: Os volumes aumentaram com o aumento da extensão de carregamento dos cateteres, profundidade de cálculo e angulação, com tendência a um aumento proporcionalmente menor para angulações maiores. As relações V150/V100 e V200/V100 foram, em geral, homogêneas, ao redor de 0,50 e 0,30, respectivamente. CONCLUSÃO: A distribuição de dose na situação considerada padrão é em geral adequada. Nenhum parâmetro específico que pudesse ser relacionado à maior toxicidade foi identificado. Recomendamos uma avaliação rápida da qualidade do implante por meio da análise das relações V150/V100 e V200/V100.


OBJECTIVE: To evaluate the dose distribution in different situations of high dose-rate endobronchial brachytherapy, focusing especially on high-dose volumes, and try to identify better or worse situations in terms of dose distribution to aid as guidance in the clinical practice. MATERIALS AND METHODS: Theoretical study simulating high dose-rate endobronchial brachytherapy utilizing two catheters, varying the loading extent, angle between the catheters, prescription depth, and source step. With a prescription dose of 7.5 Gy, the volumes involved by the 100 percent, 150 percent and 200 percent isodoses (V100, V150 and V200, respectively) and V150/V100 and V200/V100 ratios were calculated. RESULTS: There was a volume enhancement with larger loaded lengths, increase in prescription depth and angles, with a tendency towards a proportionally smaller increase with larger angulations. In general, the V150/V100 and V200/V100 ratios were homogeneous, respectively around 0.50 and 0.30. CONCLUSION: Overall, the dose distribution in the standard situation was appropriate. No specific parameter that could be related to a higher toxicity was identified. The authors recommend a swift evaluation of the treatment quality through the analysis of the V150/V100 and V200/V100 ratios.


Subject(s)
Humans , Brachytherapy , Radiation Dosage , Dosimetry/analysis , Catheters , Reference Standards
4.
Univ. sci ; 14(1): 86-91, ene.-abr. 2009. graf
Article in Spanish | LILACS | ID: lil-603988

ABSTRACT

Desarrollar dosímetros de alanina y alanina/parafina con miras a atender la creciente utilización de la radiación ionizante a nivel tecnológico. Materiales y métodos. Los radicales libres producidos por la radiación ionizante en la alanina se detectan por resonancia magnética electrónica (ESR); la parafina se utiliza como aglutinante. La metodología de preparación incluye: elaboración, irradiación, lectura y análisis de datos para los dos tipos de dosímetros. Los espectros ESR estudiados corresponden a dosímetros de alanina con masas entre 60 y 120 mg e irradiados con dosis de 10 y 20 Gy, y dosímetros de alanina/parafina de 160 mg e irradiados con diferentes dosis en un haz de fotones de 4 MV. Resultados. La intensidad de los espectros (las cinco líneas características) depende de las dosis recibidas por los dosímetros y su relación es lineal. Con alanina pura y una dosis de 10 Gy la mínima cantidad requerida fue 120 mg; la compactación del cilindro lograda no fue suficiente para evitar la fragmentación parcial del dosímetro. La parafina no tiene señal paramagnética; en los dosímetros de alanina/parafina (cilindros de longitud 13 mm y diámetro 3.5 mm, en la relación 80:20, y buena dureza) se estudió la respuesta señal ESR-dosis en un rango entre 20 y 120 Gy. Conclusiones. Los cilindros de alanina/parafina fabricados tienen una dureza apropiada para ser manipulados como dosímetros de radiación ionizante; su reproducibilidad y la efectividad en la acumulación de dosis es buena...


Elaboration of alanine dosimeters and their possible applications in professional risks. Objective. To develop dosimeters of alanine and alanine/paraffin in order to meet the growing use of ionizing radiation at the technological level. Materials and methods. Free radicals produced by ionizing radiation in alanine are detected by electron spin resonance (ESR); paraffin is used as binder. The methodology ofpreparation includes: elaboration, irradiation, data collection and data analysis for the two types of dosimeters. The ESR spectra studied correspond to alanine dosimeters with masses between 60 and 120 mg and irradiated with doses of 10 and 20 Gy, and alanine/paraffin dosimeters with 160 mg and irradiated with different doses in a beam of photons 4 MV. Results. The intensity of the spectra (thecharacteristic five lines) depends on the doses received by the dosimeters and their relationship is linear. With pure alanine and a dose of 10 Gy, the minimum amount required was 120 mg; the achieved cylinder compaction was not sufficient to avoid the partial fragmentation of the dosimeter. Paraffin has no paramagnetic signal; in the alanine/paraffin dosimeters (cylinders of 13 mm in length and 3.5 mm of diameter, with a ratio 80:20, and good hardness) the response signal ESR-dose was studied in a range between 20 and 120 Gy. Conclusions. The cylinders of alanine/paraffin manufactured have an appropriate hardness to be handled as dosimeters of ionizing radiation; their reproducibility and effectiveness in the accumulation of dose is good...


Elaboração de dosímetros de alanina e suas possíveis aplicações em riscos profissionais. Objetivo. Desenvolver dosímetros de alanina e alanina/parafina com a finalidade de satisfazer a crescente utilização de radiações ionizantes ao nível tecnológico. Materiais e métodos. Os radicais livres produzidos pela radiação ionizante na alanina são detectados por ressonância magnética eletrônica (EPR); a parafina é utilizada como aglutinante. O método de preparação inclui: elaboração, irradiação, leitura e analise dos dados para os dois tiposde dosímetros. Os espectros ESR estudados correspondem a dosímetros de alanina com massas entre 60 e 120 mg e irradiados com doses de 10 e 20 Gy, e dosímetros de alanina/parafina de 160 mg e irradiados com diferentes doses de um feixe de fótons de 4 MV. Resultados.A intensidade dos espectros (as cinco linhas características) depende das doses recebidas pelos dosímetros e sua relação é linear. Com lanina pura e uma dose de 10 Gy a mínima quantidade requerida foi de 120 mg; a compactação do cilindro alcançada não foi suficiente para evitar a fragmentação parcial do dosímetro. A parafina não tem sinal paramagnético; nos dosímetros de alanina/parafina (cilindros de 13 mmde comprimento e 3,5 mm de diâmetro, na proporção 80:20 e boa dureza) foi estudada a resposta a sinal ESR-dose em um intervalo entre 20 e 120 Gy. Conclusões. Os cilindros de alanina/parafina fabricados têm uma dureza adequada para ser tratados como dosímetros de radiação ionizante; sua reprodutibilidade e eficiência no acúmulo de dose é bom...


Subject(s)
Dosimetry/analysis , Radiation, Ionizing
SELECTION OF CITATIONS
SEARCH DETAIL