Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Rev. bras. cir. cardiovasc ; 30(4): 466-473, July-Aug. 2015. tab, graf
Article in English | LILACS | ID: lil-763160

ABSTRACT

AbstractObjective:The present study investigated effect of using pump on postoperative pleural effusion in patients who underwent coronary artery bypass grafting.Methods:A total of 256 patients who underwent isolated coronary artery bypass grafting surgery in the Cardiovascular Surgery clinic were enrolled in the study. Jostra-Cobe (Model 043213 105, VLC 865, Sweden) heart-lung machine was used in on-pump coronary artery bypass grafting. Off-pump coronary artery bypass grafting was performed using Octopus and Starfish. Proximal anastomoses to the aorta in both on-pump and off-pump techniques were performed by side clamps. The patients were discharged from the hospital between postoperative day 6 and day 11.Results:The incidence of postoperative right pleural effusion and bilateral pleural effusion was found to be higher as a count in Group 1 (on-pump) as compared to Group 2 (off-pump). But the difference was not statistically significant [P>0.05 for right pleural effusion (P=0.893), P>0.05 for bilateral pleural effusion (P=0.780)]. Left pleural effusion was encountered to be lower in Group 2 (off-pump). The difference was found to be statistically significant (P<0.05, P=0.006).Conclusion:Under the light of these results, it can be said that left pleural effusion is less prevalent in the patients that underwent off-pump coronary artery bypass grafting when compared to the patients that underwent on-pump coronary artery bypass grafting.


ResumoIntrodução:O presente estudo investigou efeito da utilização de bomba em derrame pleural pós-operatório nos casos de pacientes que se submeteram à cirurgia de revascularização miocárdica.Métodos:Um total de 256 pacientes que foram submetidos à cirurgia de revascularização isolada no ambulatório de Cirurgia Cardiovascular foram incluídos no estudo. Máquina coração-pulmão Jostra-Cobe (Modelo 043213 105, VLC 865, Suécia) foi utilizada em cirurgia de revascularização miocárdica com circulação extracorpórea. Cirurgia de revascularização miocárdica sem circulação extracorpórea foi realizada utilizando Octopus e Starfish. Anastomose proximal na aorta, em ambas as técnicas, foi realizada por grampos laterais. Os pacientes receberam alta do hospital entre os dias 6 e 11 de pós-operatório.Resultados:A incidência de derrame pleural à direita pós-operatória e derrame pleural bilateral encontrada foi mais elevada em contagem do Grupo 1 (com circulação extracorpórea) em relação ao Grupo 2 (sem circulação extracorpórea). Mas a diferença não foi estatisticamente significativa [P>0,05 para derrame pleural à direita (P=0,893), P>0,05 para derrame pleural bilateral (P=0,780)]. O derrame pleural esquerdo encontrado foi menor no Grupo 2 (CEC). A diferença foi estatisticamente significativa (P<0,05, P=0,006).Conclusão:Sob a luz destes resultados, pode-se dizer que derrame pleural esquerdo é menos prevalente nos pacientes que foram submetidos à revascularização do miocárdio sem circulação extracorpórea em comparação com os pacientes que foram submetidos à revascularização do miocárdio com circulação extracorpórea.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Coronary Artery Bypass/adverse effects , Extracorporeal Circulation/instrumentation , Pleural Effusion/epidemiology , Postoperative Complications/epidemiology , Body Mass Index , Coronary Artery Bypass, Off-Pump/adverse effects , Coronary Artery Bypass, Off-Pump/instrumentation , Coronary Artery Bypass/instrumentation , Incidence , Patient Discharge , Pleural Effusion/etiology , Retrospective Studies , Treatment Outcome
2.
Rev. bras. anestesiol ; 64(6): 395-399, Nov-Dec/2014. tab
Article in English | LILACS | ID: lil-728871

ABSTRACT

Background and objectives: The intense trauma response triggered by cardiopulmonary bypass can lead to increased morbidity and mortality. The present study evaluated whether clonidine, a drug of the class of α-2 agonists, administered by spinal route, without association with local anesthetics or opioids, reduces this response in cardiac surgery with cardiopulmonary bypass. Method: A total of 27 patients between 18 and 75 years old, divided by non-blinded fashion into a control group (15) and a clonidine group (12), were studied. All patients underwent identical technique of general anesthesia. Then, only the clonidine group received 1 μg kg−1 clonidine by spinal route. Levels of blood glucose, lactate and cortisol were measured at three consecutive times: T1, at the time of installation of invasive arterial pressure; T2, 10 min after the first dose for cardioplegia; and T3, at the time of skin suture; and troponin I values at T1 and T3. The variation of results between T2-T1, T3-T2, and T3-T1 was also evaluated. Results: There was a statistically significant difference only with respect to the variation in blood glucose in the clonidine group: T3-T2, p = 0.027 and T3-T1, p = 0.047. Conclusions: Spinal clonidine at a dose of 1 μg kg−1 did not decrease blood measurements of troponin, cortisol, or lactate. Blood glucose suffered a more moderate variation during the procedure in the clonidine group. This fact, already reported in the literature, requires further investigation to be clarified. .


Justificativa e objetivos: A intensa resposta ao trauma desencadeada pela circulação extracorpórea pode conduzir ao aumento da morbimortalidade. 0 presente estudo avaliou se a clonidina, fàrmaco da classe dos α-2 agonistas, por via raquidiana, sem associação com anestésicos locais ou opioides, reduz essa resposta em cirurgias cardíacas com uso de circulação extracorpórea. Método: Estudaram-se 27 pacientes entre 18 e 75 anos, separados de modo não encoberto em grupo controle (15) e grupo clonidina (12). Todos foram submetidos a técnica idéntica de anestesia geral. A seguir, apenas o grupo clonidina recebeu 1 mg.kg−1 de clonidina por via raquidiana. Foram dosados os valores de glicemia, lactato e cortisol em trés tempos consecutivos: T1, no momento da instalação da pressão arterial invasiva (PAM); T2, dez minutos após a primeira dose de cardioplegia; e T3 na sutura da pele, bem como os valores de troponina I em T1 e T3. Avaliou-se também a variação dos resultados entre: T2-T1; T3-T2 e T3-T1. Resultados: Houve diferença estatisticamente significativa apenas quanto à variação da glicemia no grupo clonidina: T3-T2 valor de p=0,027 e T3-T1 valor de p = 0,047. Conclusões: A clonidina espinhal em dose de 1 μg.kg−1 não diminuiu as dosagens sanguineas de troponina, cortisol ou lactato. A glicemia sofreu urna menor variação durante o procedimento no grupo clonidina. Esse fato, já registrado na literatura, necessita de maiores investigações para ser esclarecido. .


Introducción y objetivos: La intensa respuesta al trauma desencadenada por la circulación extracorpórea puede conducir al aumento de la morbimortalidad. El presente estudio eva-luó si la clonidina, fármaco de la clase de los α-2 agonistas, por vía raquídea, sin asociación con anestésicos locales u opiáceos, reduce esa respuesta en cirugías cardíacas con el uso de circulación extracorpórea. Método: Se estudiaron 27 pacientes entre 18 y 75 años, separados de modo no enmascarado en un grupo control (15) y un grupo clonidina (12). Todos fueron sometidos a la técnica idéntica de anestesia general. A continuación, solamente el grupo clonidina recibió 1 mgkg−1 de clonidina por vía raquídea. Se dosificaron los valores de glucemia, lactato y cortisol en 3 tiempos consecu-tivos: T1, al momento de la instalación de la presión arterial invasiva (PAP); T2, 10 min después de la primera dosis de cardioplejia; y T3 en la sutura de la piel, como también los valores de troponinai en T1 y T3. Evaluamos también la variación de los resultados entre T2-T1, T3-T2 y T3-T1. Resultados: Hubo una diferencia estadísticamente significativa solamente en cuanto a la variación de la glucemia en el grupo clonidina: T3-T2 valor de p = 0,027 y T3-T1 valor de p = 0,047. Conclusiones: La clonidina espinal en dosis de 1 μgkg−1 no disminuyó las dosificaciones sanguíneas de troponina, cortisol o lactato. La glucemia experimentó una menor variación durante el procedimiento en el grupo clonidina. Ese hecho, ya registrado en la literatura, necesita más investigaciones para ser clarificado. .


Subject(s)
Humans , Adult , Middle Aged , Aged , Stress, Physiological/drug effects , Thoracic Surgery/methods , Clonidine/administration & dosage , Extracorporeal Circulation/instrumentation
4.
Rev. bras. cir. cardiovasc ; 26(2): 205-212, abr.-jun. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-597740

ABSTRACT

INTRODUÇÃO: Bombas de roletes desempenham um papel importante na circulação extracorpórea. No entanto, a oclusão dos roletes das bombas deve ser realizada de forma adequada e estas podem ser ajustadas, principalmente por dois métodos: estático e dinâmico. OBJETIVO: Investigar como os perfusionistas brasileiros ajustam as bombas de rolete arterial em seus serviços e testar o uso de um Dispositivo Auxiliar de Calibração que facilita o ajuste pelo método de calibração dinâmica. MÉTODOS: Foi instalada uma bomba de roletes com os acessórios necessários para a realização de sua calibração pelos métodos de velocidade de queda (calibração estática) e calibração dinâmica durante o XXVIII Congresso Brasileiro de Circulação Extracorpórea. Foi solicitado aos perfusionistas que ajustassem uma bomba de roletes conforme procedimento normalmente utilizado em seu serviço. Após cada regulagem, foi medida a respectiva pressão pelo método de calibração dinâmica com o auxílio do dispositivo. O projeto foi aprovado pelo Comitê de Ética em Pesquisa da UNICAMP, sob Nº 1144/2010. RESULTADOS: Participaram da pesquisa 56 perfusionistas. A média das 56 medidas de pressão de calibração dinâmica foi 434 ± 214 mmHg; 76 por cento das medidas realizadas ficaram no intervalo preconizado para o uso da técnica de calibração dinâmica (entre 150 e 500 mmHg). CONCLUSÃO: Os perfusionistas brasileiros tendem a calibrar bombas de roletes com ajustes menos oclusivos. As amplitudes das medidas de pressão de calibração dinâmica tendem a ser menores para perfusionistas mais experientes. O dispositivo pode ser utilizado por perfusionistas para ajustar bombas de roletes com maior precisão e, principalmente, repetitividade e em alguns minutos.


INTRODUCTION: Roller pumps play an important role in extracorporeal circulation. However, occlusion of the rollers should be adequately performed and this can be adjusted mainly by two methods: static and dynamic. OBJECTIVE: To investigate how the Brazilian perfusionists adjust arterial roller pumps in their services and evaluate the application of a Device to Assist Calibration (DAC) that facilitates roller adjustment by the dynamic calibration method. METHODS: We installed a roller pump with accessories to perform adjustment by drop rate (static calibration) and dynamic calibration methods during the XXVIII Brazilian Congress of Extracorporeal Circulation. Perfusionists were asked to adjust the roller pump according to the procedure they usually do in their service. After each adjustment pressure was measured by dynamic calibration method with DAC. The research was approved by the Research Ethics Committee of UNICAMP, Nº 1144/2010. RESULTS: There were 56 perfusionists in this study. Pressure average of 56 measurements of dynamic calibration was 434 ± 214 mmHg; 76 percent of measurements were within the recommended range for the use of the dynamic calibration method (between 150 and 500 mmHg). CONCLUSION: Brazilian perfusionists tend to adjust roller pumps with less occlusive settings. The amplitudes of the dynamic calibration pressure tend to be smaller for more experienced perfusionists because their skills increase with time. The device can be used by the perfusionist to adjust roller pumps with greater accuracy and mainly repeatability in few minutes.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Extracorporeal Circulation/instrumentation , Infusion Pumps/standards , Allied Health Occupations , Calibration
6.
Rev. bras. eng. biomed ; 26(1): 25-32, abr. 2010. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-570336

ABSTRACT

As bombas de roletes ocupam um papel de destaque entre os dispositivos utilizados na circulação extracorpórea, pois são responsáveis pela movimentação do sangue. O ajuste adequado desses equipamentos é fundamental para minimizar o trauma nas células sanguíneas. O presente trabalho analisou dois métodos para ajuste das bombas: o método de medida de velocidade de queda e a calibração dinâmica em dois modelos de bombas, com o objetivo de avaliar as suas variações e limitações práticas de uso em centro cirúrgico. A velocidade de queda foi medida em dois modelos de bombas de roletes e em três pontos do leito rígido com valor final calculado pela média entre eles. A calibração dinâmica foi medida sequencialmente às medidas de velocidade de queda, e os valores médios de pressão foram registrados em arquivo, com intervalo entre medidas de 20 ms. Os valores médios de velocidade de queda mostraram diferenças significantes (p < 0,0007), quando comparados com os valores mínimos e entre os dois modelos de bombas. Nos dois métodos analisados foram observadas variações de ajuste entre os roletes, com possíveis consequências para a hemólise. A bomba 1 mostrou descentralização do leito rígido entre os pontos medidos (p < 0,02). O método de ajuste por medida de velocidade de queda mostrou erros em seus valores absolutos e com dificuldade de repetitividade e não foi possível estabelecer correlação com a respectiva medida de calibração dinâmica.


Roller pumps have an important role among the devices used in cardiopulmonary bypass, being responsible for pumping blood. The setting of pumps is essential to minimize the trauma on blood cells. This study examined two methods for pump adjustment: the drop rate method and dynamic calibration method, applied to two different pumps in order to evaluate their variations and practical limitations of use in operating room. The drop rate was measured in the lowest point of pump raceway (0º) and in two other points close to it (–20º and +20º) and the average values of the three points was also taken. The dynamic calibration was measured sequentially, and the pressure average values were recorded on file with a sampling interval of 20 ms. There were significant differences (p < 0.0007) in drop rate averages when compared with the lowest point in the two types of pumps. In two pumps were observed variations in settings between rollers with possible consequences for the hemolysis. The pump 1 showed decentralization in raceway between points measured (p < 0.02). The drop rate method showed errors in their absolute values and with limited repeatability, and it was not possible to correlate with their dynamic calibration measurements.


Subject(s)
Extracorporeal Circulation/instrumentation , Extracorporeal Circulation/standards , Calibration , Pulsatile Flow , Hemolysis , Hydrodynamic Models/methods , Cardiopulmonary Bypass/instrumentation
7.
Arch. cardiol. Méx ; 77(4): 326-329, oct.-dic. 2007. ilus
Article in Spanish | LILACS | ID: lil-567015

ABSTRACT

In this year, we commemorate half a century of the first open-heart surgery performed in Mexico at the Military Hospital on January 11, 1957. The surgery was performed in a child with interventricular communication by Dr. Raul Baz; in this surgery a De Wall and Lillehei bubble oxygenator was used. The perfusionist was Dr. Marcelo García Cornejo. The present historical review is aimed at covering the advances in cardiology from its beginnings to the present.


Subject(s)
History, 20th Century , Extracorporeal Circulation , Equipment Design , Extracorporeal Circulation/instrumentation , Mexico
8.
Vis. enferm. actual ; 3(12): 6-11, dic. 2007.
Article in Spanish | LILACS | ID: lil-519978

ABSTRACT

El autor describe la técnica de circulación extracorpórea en cirugía cardiovascular. Utilizando un lenguaje sencillo, se adentra en el conocimiento de la práctica quirúrgica y la aplicación del procedimiento. Comienza con una reseña histórica, para describir luego la técnica, sus componentes y sus aplicaciones al día de la fecha.


Subject(s)
Humans , Extracorporeal Circulation/instrumentation , Thoracic Surgery , Filters , Oxygenation
9.
Rev. bras. eng. biomed ; 22(1): 43-49, abr. 2006. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-490938

ABSTRACT

Este trabalho apresenta o desenvolvimento e a avaliação de um transdutor óptico de reflectância para monitoração da saturação de oxigênio (SO2) no sangue arterial e venoso fluindo pelo circuito de circulação extracorpórea (CEC). O transdutor opera com dois diodos emissores de luz com picos de emissão nas faixas do espectro do vermelho e do infravermelho e um fotodiodo. O transdutor óptico é utilizado em conjunto com um conector transparente, especialmente projetado para ser colocado na linha do circuito de CEC sem alterar o escoamento do sangue. O desempenho de quatro transdutores ópticos foi avaliado em ensaios in vitro e durante monitoração da SO2 em pacientes (n = 16) submetidos à cirurgia cardíaca com CEC. Nos ensaios in vitro utilizou-se sangue de cães em um sistema para simulação de CEC. Os índices de correlação entre os valores de SO2 medidos por reflectância óptica e a SO2 medida por aparelho comercial de gasometria foram de 0,9979 ± 0,0004 nos ensaios in vitro e 0,87 ± 0,05 nas cirurgias com CEC. Os resultados demonstram a possibilidade de se utilizar o princípio de reflectância óptica em 2 comprimentos de onda de luz para determinar a SO2 de forma contínua e em tempo real durante cirurgias com CEC.


Subject(s)
Extracorporeal Circulation/instrumentation , Extracorporeal Circulation/methods , Blood Circulation , Blood Gas Monitoring, Transcutaneous/methods , Oxygen Level/analysis , Oxygen Level/methods , Transducers
12.
Rev. bras. eng. biomed ; 16(2): 109-120, maio-ago. 2000. ilus, tab
Article in Portuguese | LILACS | ID: lil-358882

ABSTRACT

Desde a primeira cirurgia cardíaca usando a técnica de circulação extracorpórea (CEG) em 1953, o avanço dos materiais e equipamentos e da própria técnica tem sido notável, reduzindo consideravelmente a ocorrência de acidentes relacionados à falhas mecânicas e/ou elétricas. Por outro lado, acidentes provocados por falha humana ainda ocorrem com certa freqüência, destacando-se a embolia aérea, na qual o reservatória de sangue do oxigenador esvazia-se em poucos segundos sem que o perfusionista perceba, resultando em uma injeção maciça de ar no paciente podendo deixá-lo com seqüelas graves ou levá-lo à morte. Visando aumentar a segurança da CEG e reduzir a possibilidade de ocorrência de embolia aérea provocada pelo esvaziamento acidental do oxigenador, foi desenvolvido um sistema de controle do nível de sangue no oxigenador que utiliza um sensor ultra-sônico e controla automaticamente a rotação da bomba sistêmica, além de acionar alarmes audiovisuais. Os resultados experimentais demonstraram a eficácia do equiapmento.


Subject(s)
Oxygenators , Automation/instrumentation , Extracorporeal Circulation/instrumentation , Thoracic Surgery/instrumentation , Heart-Lung Machine/adverse effects , Heart-Lung Machine/trends
14.
Rev. Inst. Nac. Enfermedades Respir ; 10(4): 281-5, oct.-dic. 1997.
Article in Spanish | LILACS | ID: lil-214370

ABSTRACT

El presente trabajo pretende describir algunos conceptos básicos del bypass cardiopulmonar cuando es utilizado en protocolos de investigación en modelos animales. Describimos los aspectos técnicos de interés que debe conocer el investigador y el personal que trabaja en centros hospitalarios donde se realizan estos procedimientos de perfusión. El perfusionista es el especialista calificado en manejar la bomba de circulación extracorpórea durante situaciones médicas donde es necesario el soporte temporal de la función circulatoria. Además, es el experto en el conocimiento de la variedad de equipo y es responsable de su buen funcionamiento. Está capacitado para poder administrar algunos medicamentos de acuerdo al protocolo de perfusión. Es así como describimos parte del equipo de circulación extracorpórea, y algunos aspectos fisiológicos durante el bypass cardiopulmonar. En esta monografía no intentamos discutir la multitud de variaciones posibles de cómo realizar el bypass cardiopulmonar, sino que muestra los principios básicos para poder entender los circuitos extracorpóreos


Subject(s)
Extracorporeal Circulation/history , Extracorporeal Circulation/instrumentation , Extracorporeal Circulation/methods , Perfusion
16.
Rev. bras. cir. cardiovasc ; 4(3): 220-4, dez. 1989. ilus
Article in Portuguese | LILACS | ID: lil-164282

ABSTRACT

O uso de bomba centrífuga como suporte circulatório para pacientes em choque cardiogênico após a realizaçao de cirurgia cardíaca e como suporte para pacientes com falência cardíaca que estao aguardando doaçao para transplante cardíaco, tem sido progressivamente ampliado. Alquns centros utilizam a bomba centrífuga em circulaçao extracorpórea de rotina, como substituto do rolete arterial. No INCOR, operamos dois grupos de pacientes triarteriais submetidos a revascularizaçao do miocárdio, operados pelo mesmo cirurgiao, com o mesmo método de proteçao miocárdica (cardioplegia cristalóide, hipotermia sistêmica a 28 graus Celsius e tópica com soro fisiológico). Todos os parâmetros dos dois grupos foram sem diferença estatística no pré-operatório: idade, sexo superfície corpórea e parâmetros hematológicos. Foram operados 27 pacientes consecutivos e divididos, alternadamente em 13 pacientes com bomba centrífuga e 14 com rolete arterial. O oxigenador utilizado em todos foi o de bolhas da Macchi. O perfusionista foi sempre o mesmo. O tempo de perfusao médio foi de 105 minutos no Grupo 1 (rolete) e 103 minutos no Grupo 2 (bomba centrífuga). Analisamos os seguintes parârnetros: haptoglobina (HP), tempo de de tromboplastina parcial ativada (TTPA), tempo de trombina (TT) e número e plaquetas pré e pós circulaçao extracorpórea e, comparando-se os dois grupos, nao houve diferença estatística significante entre eles, nos diversos parâmetros. Concluímos que, para circulaçao extracorpórea com duraçao habitual, nao há diferença hematológica no uso da bomba centrífuga em relaçao ao rolete arterial.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Extracorporeal Circulation/instrumentation , Heart-Assist Devices , Hemolysis , Myocardial Revascularization/instrumentation
17.
In. Universidad de Antioquia. Facultad de Enfermeria. Seccion de Educacion Permanente. Actualidad en enfermeria: memorias. Medellin, Universidad de Antioquia, 1989. p.1-15, tab.
Monography in Spanish | LILACS | ID: lil-133830
SELECTION OF CITATIONS
SEARCH DETAIL