Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Einstein (Säo Paulo) ; 17(2): eAO4397, 2019. tab, graf
Article in English | LILACS | ID: biblio-1001909

ABSTRACT

ABSTRACT Objective: To demonstrate the most frequent errors in inhalation technique in patients with asthma undergoing treatment at a tertiary care hospital. Methods: A cross-sectional study with a convenience sample of asthma patients aged 18 years or over, treated at a pulmonology outpatient clinic of a tertiary care hospital. The assessment of inhalation technique of users of the dry powder inhalers Aerolizer®, Aerocaps and Diskus®, or metered-dose inhalers was based on the manufacturer's instructions for use of each inhaler device. Patients demonstrated the inhalation technique with empty inhaler devices, and it was considered correct when all stages were performed properly, or when errors probably did not interfere with the treatment outcome. Results: Among 71 participants, 43 (60.5%) performed inhalation technique incorrectly. Among metered-dose inhalers and dry powder inhalers users, inhalation technique errors were found in 84.2% and 51.9%, respectively (p=0.013). Errors were more frequent at the exhalation stage (67.4%), followed by breathing in (58.1%) and apnea (51.2%). In the group using dry powder inhalers, the most common errors occurred during exhalation and, for those using metered-dose inhalers, the most compromised stage was aspiration. Conclusion: Errors were more frequent among those using metered-dose inhalers compared with dry powder inhalers. Misconceptions are more common at the expiration stage among users of dry powder inhalers and in aspiration among those on metered-dose inhalers.


RESUMO Objetivo: Demonstrar os erros mais frequentes na técnica inalatória de pacientes com asma brônquica em tratamento em hospital terciário. Métodos: Estudo transversal, com amostra de conveniência de pacientes com asma, com 18 anos ou mais, em tratamento em ambulatório de pneumologia de um hospital terciário. A avaliação da técnica inalatória dos usuários dos dispositivos de pó seco Aerolizer ®, Aerocaps® ou Diskus®, ou de aerossóis dosimetrados teve como base as orientações da bula do fabricante de cada dispositivo inalatório. Os pacientes demonstraram a técnica inalatória com dispositivos inalatórios vazios, e ela foi considerada correta quando todas as etapas foram realizadas de forma apropriada, ou quando os equívocos provavelmente não interferiam no resultado do tratamento. Resultados: Entre os 71 participantes, 43 (60,5%) realizaram a técnica inalatória de forma incorreta. Dentre os usuários de aerossóis dosimetrados e dispositivos de pó seco, ocorreram erros de técnica inalatória em 84,2% e 51,9%, respectivamente (p=0,013). Os erros foram mais frequentes na etapa da expiração (67,4%), seguidos da aspiração (58,1%) e da apneia (51,2%). No grupo que usava dispositivos de pó seco, os erros mais comuns aconteceram na expiração e, nos que utilizavam aerossóis dosimetrados, a etapa mais comprometida foi a aspiração. Conclusão: Os erros foram mais frequentes entre os que usavam aerossóis dosimetrados em comparação com dispositivos de pó seco. Os equívocos foram mais comuns na etapa da expiração entre os usuários de dispositivos de pó seco e na aspiração entre os que usavam aerossóis dosimetrados.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Asthma/drug therapy , Administration, Inhalation , Medication Errors , Socioeconomic Factors , Self Administration/standards , Patient Education as Topic , Cross-Sectional Studies , Metered Dose Inhalers , Dry Powder Inhalers/instrumentation , Tertiary Care Centers
2.
Rev. latinoam. enferm ; 17(4): 474-480, July-Aug. 2009. tab
Article in English, Spanish, Portuguese | LILACS, BDENF | ID: lil-528838

ABSTRACT

This cross-sectional study aimed to describe the most common correct and incorrect self-administration techniques for insulin using disposable syringes by patients cared for by the Family Health Strategy (FHS), relate the findings to sociodemographic variables and also identify the professional responsible for teaching this technique. A total of 169 patients were selected by simple random sampling in 37 FHS units in a city in the state of Minas Gerais, Brazil from August to October 2006. The results identified errors in all the steps recommended by the American Diabetes Association and Brazilian Diabetes Association for the safe administration of insulin, from hand washing to compression on the injection site. The FHS favors the development of interventions focused on the needs of the clientele registered at the unit, stimulating self-care. Results from this study can contribute to the planning of these interventions.


Se trata de un estudio seccional que tuvo como objetivó describir los errores y los aciertos más comunes de la técnica de auto aplicación de insulina, con jeringas desechables, por los usuarios, acompañados por la Estrategia Salud de la Familia (ESF), así como relacionar lo encontrado a las variables sociodemográficas e identificar al profesional responsable por las orientaciones. Participaron 169 usuarios, seleccionados por medio de un muestreo aleatorio simple, en 37 unidades de la ESF, de un municipio del Estado de Minas Gerais, entre agosto y octubre de 2006. Los resultados identificaron errores en todos los pasos recomendados por la Asociación Americana de Diabetes y la Sociedad Brasileña de Diabetes para la aplicación segura de la insulina, desde el lavado de las manos hasta la compresión del local de aplicación. La ESF favorece el desarrollo de intervenciones con foco en las necesidades de la clientela adscrita, estimulándola para el auto cuidado, y los resultados del presente estudio podrán contribuir para la planificación de esas intervenciones.


Estudo seccional que objetivou descrever os erros e os acertos mais comuns da técnica de autoaplicação de insulina, com seringas descartáveis, pelos usuários, acompanhados pela Estratégia Saúde da Família (ESF), assim como relacionar esses achados às variáveis sociodemográficas e identificar o profissional responsável pelas orientações. Participaram 169 usuários selecionados por meio de amostragem aleatória simples, em 37 unidades da ESF, de um município do Estado de Minas Gerais, entre agosto e outubro de 2006. Os resultados identificaram erros em todos os passos recomendados pela Associação Americana de Diabetes e Sociedade Brasileira de Diabetes para a aplicação segura da insulina, desde a lavagem das mãos até a compressão do local de aplicação. A ESF favorece o desenvolvimento de intervenções centradas nas necessidades da clientela adscrita, estimulando-a para o autocuidado, e os resultados do presente estudo poderão contribuir para o planejamento dessas intervenções.


Subject(s)
Humans , Male , Middle Aged , Diabetes Mellitus/drug therapy , Insulin/administration & dosage , Self Administration/standards , Cross-Sectional Studies , Disposable Equipment , Self Administration/instrumentation , Self Administration/methods , Syringes
SELECTION OF CITATIONS
SEARCH DETAIL