1.
The Korean Journal of Internal Medicine ; : 481-485, 2013.
Artículo en Inglés | WPRIM | ID: wpr-212575

RESUMEN

Coronary stent dislodgement is a rare complication of percutaneous coronary intervention. We report a case of stent dislodgement in the ascending thoracic aorta. The stent was mechanically distorted in the left circumflex artery (LCX) while being delivered to the proximal LCX lesion. The balloon catheter was withdrawn, but the stent with the guide wire was remained in the ascending thoracic aorta. The stent was unable to be retrieved into the guide catheter, as it was distorted. A goose neck snare was used successfully to catch the stent in the ascending thoracic aorta and retrieved the stent externally via the arterial sheath.


Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Angioplastia Coronaria con Balón/efectos adversos , Aorta Torácica/diagnóstico por imagen , Cateterismo Cardíaco/efectos adversos , Angiografía Coronaria , Remoción de Dispositivos/instrumentación , Cuerpos Extraños/etiología , Radiografía Intervencional , Stents , Resultado del Tratamiento
2.
The Korean Journal of Internal Medicine ; : 718-723, 2013.
Artículo en Inglés | WPRIM | ID: wpr-157974

RESUMEN

Coronary stent dislodgement is a rare complication of percutaneous coronary intervention. We report a rare case of dislodgement of two intracoronary stents. On withdrawal of two balloon catheters, one with a guide wire was mechanically distorted from the left main (LM) to the proximal left anterior descending artery (LAD) while the other was dislodged from the LM to the ostial left circumflex artery. The stent in the LAD could not be retrieved into the guide catheter using a Goose neck snare, because it was caught on a previously deployed stent at the mid LAD. A new stent was quickly deployed from the LM to the proximal LAD, because the patient developed cardiogenic shock. Both stents, including a distorted and elongated stent, were crushed to the LM wall. Stent deployment and crushing may be a good alternative technique to retrieving a dislodged stent.


Asunto(s)
Femenino , Humanos , Persona de Mediana Edad , Angioplastia Coronaria con Balón/efectos adversos , Cateterismo Cardíaco/efectos adversos , Angiografía Coronaria , Estenosis Coronaria/diagnóstico , Falla de Prótesis , Choque Cardiogénico/etiología , Stents , Resultado del Tratamiento