Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Korean Academy of Conservative Dentistry ; : 26-36, 2011.
Artículo en Inglés | WPRIM | ID: wpr-94348

RESUMEN

OBJECTIVES: In the present study, three kinds of tissues cells (pulp, gingiva, and periodontal ligament) were investigated if those cells express MMP and TIMP when they were stimulated with neuropeptides (substance P, CGRP) or proinflammatory cytokine, TNF-alpha. MATERIALS AND METHODS: The cells cultured from human dental pulp (PF), gingiva (GF) and periodontal ligament were (PDLF) stimulated with Mock, SP, TNF-alpha, and CGRP for 24 hrs and 48 hrs. for an RNase protection assay and Enzyme Linked Immunosorbent Assay. Cells (PF, GF and PDLF) seeded in 100 mm culture dish were stimulated with SP (10(-5), 10(-8) M) or only with medium (Mock stimulation) for 4hrs and for 24 hrs for RNase Protection Assay, and they were stimulated with CGRP (10(-5) M) and TNF-alpha (2 ng/mL) for 24 hrs and with various concentraion of TNF-alpha (2, 10, and 100 ng/mL) for Rnase Protection Assay with a human MMP-1 probe set including MMP 1, 2, 8, 7, 8, 9, 12, and TIMP 2, 3. In addition, cells (PF, GF and PDLF) were stimulated with Mock and various concentraion of TNF-alpha(2, 10, and 100 ng/mL) for 24 hrs and with TNF-alpha(10 ng/mL) for 48 hrs, and the supernatents from the cells were collected for Enzyme Linked Immunosorbent Assay (ELISA) for MMP-1 and MMP-13. RESULTS: The expression of MMPs in PF, GF, PDLF after stimulation with SP and CGRP were not changed compared with Mock stimulation for 4 hrs and 24 hrs. The expression of MMP-1, -12, -13 24 hrs after stimulation with TNF-alpha were upregulated, however the expression of TIMP-3 in PF, GF, PDLF after stimulation with TNF-alpha were downregulated. TNF-alpha (2 ng/mL, 10 ng/mL, 100 ng/mL) increased MMP-1 and MMP-12 expression in PF dose dependently for 24 hrs. CONCLUSIONS: TNF-alpha in the area of inflammation may play an important role in regulating the remodeling of dentin, cementum, and alveolar bone.


Asunto(s)
Humanos , Cemento Dental , Pulpa Dental , Dentina , Ensayo de Inmunoadsorción Enzimática , Encía , Inflamación , Metaloproteinasas de la Matriz , Neuropéptidos , Ligamento Periodontal , Ribonucleasas , Semillas , Sustancia P , Inhibidor Tisular de Metaloproteinasa-3 , Factor de Necrosis Tumoral alfa
2.
Journal of Korean Academy of Conservative Dentistry ; : 461-472, 2010.
Artículo en Inglés | WPRIM | ID: wpr-158029

RESUMEN

OBJECTIVES: This study evaluated microtensile bond strength (microTBS) and short-rod fracture toughness to explain fractural behavior of repaired composite restorations according to different surface treatments. MATERIALS AND METHODS: Thirty composite blocks for microTBS test and sixty short-rod specimens for fracture toughness test were fabricated and were allocated to 3 groups according to the combination of surface treatment (none-treated, sand blasting, bur roughening). Each group was repaired immediately and 2 weeks later. Twenty-four hours later from repair, microTBS and fracture toughness test were conducted. Mean values analyzed with two-way ANOVA / Tukey's B test (alpha = 0.05) and correlation analysis was done between microTBS and fracture toughness. FE-SEM was employed on fractured surface to examine the crack propagation. RESULTS: The fresh composite resin showed higher microTBS than the aged composite resin (p < 0.001). Mechanically treated groups showed higher bond strength than non-mechanically treated groups except none-treated fresh group in microTBS (p < 0.05). The fracture toughness value of mechanically treated surface was higher than that of non-mechanically treated surface (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. Specimens having high KIC showed toughening mechanism including crack deviation, microcracks and crack bridging in FE-SEM. CONCLUSIONS: Surface treatment by mechanical interlock is more important for effective composite repair, and the fracture toughness test could be used as an appropriate tool to examine the fractural behavior of the repaired composite with microtensile bond strength.


Asunto(s)
Anciano , Humanos , Dióxido de Silicio
3.
Journal of Korean Academy of Conservative Dentistry ; : 211-221, 2010.
Artículo en Inglés | WPRIM | ID: wpr-58040

RESUMEN

Proteoglycan is highly hydrophilic and negatively charged which enable them attract the water. The objective of study was to investigate the effects of Proteoglycan on microtensile bond strength of dentin adhesives and on architecture of dentin collagen matrix of acid etched dentin by removing the chondroitin sulphate attached on Proteoglycan. A flat dentin surface in mid-coronal portion of tooth was prepared. After acid etching, half of the specimens were immersed in 0.1 U/mL chondroitinase ABC (C-ABC) for 48 h at 37degrees C, while the other half were stored in distilled water. Specimens were bonded with the dentin adhesive using three different bonding techniques (wet, dry and re-wet) followed by microtensile bond strength test. SEM examination was done with debonded specimen, resin-dentin interface and acid-etched dentin surface with/without C-ABC treatment. For the subgroups using wet-bonding or dry-bonding technique, microtensile bond strength showed no significant difference after C-ABC treatment (p > 0.05). Nevertheless, the subgroup using rewetting technique after air dry in the Single Bond 2 group demonstrated a significant decrease of microtensile bond strength after C-ABC treatment. Collagen architecture is loosely packed and some fibrils are aggregated together and relatively collapsed compared with normal acid-etched wet dentin after C-ABC treatment. Further studies are necessary for the contribution to the collagen architecture of noncollagenous protein under the various clinical situations and several dentin conditioners and are also needed about long-term effect on bond strength of dentin adhesive.


Asunto(s)
Adhesivos , Bisfenol A Glicidil Metacrilato , Condroitín , Condroitina ABC Liasa , Sulfatos de Condroitina , Colágeno , Dentina , Proteoglicanos , Diente , Agua
4.
Journal of Korean Academy of Conservative Dentistry ; : 69-79, 2010.
Artículo en Coreano | WPRIM | ID: wpr-70548

RESUMEN

The purpose of this study was to evaluate the effect of film thickness of various resin cements on bonding efficiency in indirect composite restoration by measurement of microtensile bond strength, polymerization shrinkage, flexural strength and modulus, fractographic FE-SEM analysis. Experimental groups were divided according to film thickness ( 0.05). 3. Panavia F showed significantly lower polymerization shrinkage than other resin cements (p < 0.05). 4. Composite-based resin cements showed significantly higher flexural strength and modulus than adhesive-based resin cements (p < 0.05). 5. FE-SEM examination showed uniform adhesive layer and well developed resin tags in composite-based resin cements but unclear adhesive layer and poorly developed resin tags in adhesive-based resin cements. In debonded surface examination, composite-based resin cements showed mixed failures but adhesive-based resin cements showed adhesive failures.


Asunto(s)
Adhesivos , Polimerizacion , Polímeros , Cementos de Resina
5.
Journal of Korean Academy of Conservative Dentistry ; : 88-95, 2010.
Artículo en Coreano | WPRIM | ID: wpr-70546

RESUMEN

The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.


Asunto(s)
Colodión , Cavidad Pulpar
6.
Journal of Korean Academy of Conservative Dentistry ; : 137-144, 2009.
Artículo en Coreano | WPRIM | ID: wpr-164696

RESUMEN

The aim of this study was to investigate the shapes and diameters of the physiological foramen and anatomy of the root canal at 3mm from apex in mandibular first molars. Sixty mandibular first molars were randomly selected. The apical anatomy of 60 mandibular first molars was investigated by means of a stereomicroscope (60x magnification). The results were as follows; 1. There was a high percentage of two physiological foramina in mesial (61.67%) and one foramen in distal(71.66%) roots of mandibular first molars. 2.There was a high frequency of accessory foramina in mesial roots with one foramen (26.07%). 3. The diameters of physiological foramen was as follows: 0.329mm in single mesial foramen. 0.266mm in mesiobuccal foramen and 0.246mm in mesiolingual foramen. 0.375mm in single distal foramen. 0.291mm in distobuccal foramen and 0.237mm in distolingual foramen. 4. The most common physiological foramen shape was oval (69.93%). 5. The incidence of isthmus in mesial root at 3mm from apex was 55%. The 3mm-sections contained a complete isthmus 31.66% and a partial isthmus 23.34%. 6. 3mm from the apex, the most common canal shape was oval (50.64%). Knowledge of the apical anatomy of mandibular first molar would be necessary for success of surgical and nonsurgical endodontic treatment.


Asunto(s)
Cavidad Pulpar , Incidencia , Diente Molar , Ápice del Diente
7.
Journal of Korean Academy of Conservative Dentistry ; : 537-550, 2009.
Artículo en Coreano | WPRIM | ID: wpr-61594

RESUMEN

During the last two decades, there has been an increasing interest in the impact of oral health on atherosclerosis and subsequent cardiovascular disease (CVD). To date, some periodontal pathogens including Porphyromonas gingivalis (P. gingivalis) have been reported to be relevant to CVD. Porphyromonas endodontalis (P. endodontalis), which shares approximately 87% sequence homology with P. gingivalis, is mostly found within infected root canals. However, recent studies reveal that this pathogen also resides in the dental plaque or periodontal pocket in patients with periodontitis. It has been shown that P. endodontalis invades human coronary artery endothelial cells (HCAEC) and coronary artery smooth muscle cells (CASMC). To evaluate whether P. endodontalis can participate in the progression of atherosclerosis and CVD, we examined the changes in transcriptional gene expression profiles of HCAEC responding to invasion by P. endodontalis in this study. The following results were obtained. 1. Porphyromonas endodontalis was invasive of HCAEC. 2. According to the microarray analysis, there were 625 genes upregulated more than two-folds, while there were 154 genes downregulated by half. 3. Upregulated genes were relevant to inflammatory cytokines, apoptosis, coagulation and immune response. Enhanced expression of MMP-1 was also noticeable. 4. The transcription profiles of the 10 selected genes examined by real-time PCR agreed well with those observed in the microarray analysis. Thus, these results show that P. endodontalis presents the potential to trigger and augment atherosclerosis leading to CVD.


Asunto(s)
Humanos , Apoptosis , Aterosclerosis , Enfermedades Cardiovasculares , Vasos Coronarios , Citocinas , Placa Dental , Cavidad Pulpar , Células Endoteliales , Expresión Génica , Análisis por Micromatrices , Miocitos del Músculo Liso , Salud Bucal , Bolsa Periodontal , Periodontitis , Porphyromonas , Porphyromonas endodontalis , Porphyromonas gingivalis , Reacción en Cadena en Tiempo Real de la Polimerasa , Homología de Secuencia , Transcriptoma
8.
Journal of Korean Academy of Conservative Dentistry ; : 430-441, 2009.
Artículo en Coreano | WPRIM | ID: wpr-31981

RESUMEN

The purpose of this study was to characterize functional distinction between human dental pulp cells(PC) and periodontal ligament cells(PDLC) using cDNA microarray assay and to confirm the results of the microarray assay using RT-PCR. 3 genes out of 51 genes which were found to be more expressed(>2 fold) in PC were selected, and 3 genes out of 19 genes which were found to be more expressed(>2 fold) in PDLC were selected for RT-PCR as well. According to this study, the results were as follows: 1. From the microarray assay, 51 genes were more expressed (2 fold) from PC than PDLC. 2. RT-PCR confirmed that ITGA4 and TGF beta2 were more expressed in PC than in PDLC 3. From the microarray assay, 19 genes were more expressed (2 fold) from PDLC than PC. 4. RT-PCR confirmed that LUM, WISP1, and MMP1 were more expressed in PDLC than in PC. From the present study, different expression of the genes between the PC and PDLC were characterized to show the genes which play an important role in dentinogenesis were more expressed from PC than PDLC, while the genes which were related with collagen synthesis were more expressed from PDLC than PC.


Asunto(s)
Humanos , Colágeno , Pulpa Dental , Dentinogénesis , Expresión Génica , Análisis de Secuencia por Matrices de Oligonucleótidos , Ligamento Periodontal
9.
Journal of Korean Academy of Conservative Dentistry ; : 365-376, 2007.
Artículo en Coreano | WPRIM | ID: wpr-175703

RESUMEN

The purpose of this study was to evaluate the effect of different etching times on microtensile bond strength (microTBS) to dentin both initial and after thermocycling with 3 different types of total-etching adhesives. Fifty four teeth were divided into 18 groups by etching times (5, 15, 25 sec), adhesives types (Scotchbond Multipurpose (SM), Single Bond (SB), One-Step (OS)), and number of thermocycling (0, 2,000 cycles). Flat dentin surfaces were prepared on mid-coronal dentin of extracted third molars. After exposed fresh dentin surfaces were polished with 600-grit SiC papers, each specimen was acid-etched with 35% phosphoric acid (5, 15, 25 sec) and bonded with 3 different types of total etching adhesives respectively. Then, hybrid composite Z-250 was built up. Half of them were not thermocycled (control group) and the others were subjected to 2,000 thermocycle (experimental group). They were sectioned occluso-gingivally into 1.0 x 1.0 mm2 composite-dentin beams and tested with universal testing machine at a crosshead speed of 1.0 mm/min. Within limited data of this study, the results were as follows 1. There was no statistically significant difference in microTBS between the thermocycled and non-thermocycled groups, except for both SM and SB etched for 25 sec. 2. In thermocycled SM and SB groups, bond strength decreased by extended etching time. In total etching systems, adhesive durability for dentin could be affected by type of solvents in adhesive and etching time. Especially, extended etching time may cause deteriorate effects on bond strength when ethanol-based adhesive was used.


Asunto(s)
Adhesivos , Dentina , Tercer Molar , Solventes , Diente
10.
Journal of Korean Academy of Conservative Dentistry ; : 198-207, 2007.
Artículo en Coreano | WPRIM | ID: wpr-140579

RESUMEN

The purpose of this study was to investigate the effect of calcium hydroxide on dentin bonding strength of various dentin bonding systems as a function of time in composite resin restoration. Dentin adhesives used in this study were Scotchbond Multipurpose, Single Bond, SE Bond and Prompt L-Pop. Flat dentin surfaces adjacent to pulp chamber were created, then Ca(OH)2 and saline were mixed and applied on dentin surface of experimental group, then IRM was used to cover the mixture on dentin surface and the specimens were stored at 36.5degrees C for experiment period (7 days, 30 days). After removing IRM and Ca(OH)2, each dentin adhesives were treated on dentin surfaces. Composite resin (Z-250, 3M) was placed with 5 mm height and was light-cured for 20 seconds. After stored in distilled water for 24 hours, each dentin-composite bonded spicemen was embedded in epoxy resin and sectioned into 1.0 x 1.0 mm2 cross section composite-dentin beams. Specimen was mounted on zig of Universal testing machine and microTBS test was performed. SEM analysis was performed to examine the fractured surfaces. The results suggested that applying calcium hydroxide did not show significant difference in dentin bonding strength.


Asunto(s)
Adhesivos , Hidróxido de Calcio , Calcio , Cavidad Pulpar , Dentina , Agua
11.
Journal of Korean Academy of Conservative Dentistry ; : 198-207, 2007.
Artículo en Coreano | WPRIM | ID: wpr-140578

RESUMEN

The purpose of this study was to investigate the effect of calcium hydroxide on dentin bonding strength of various dentin bonding systems as a function of time in composite resin restoration. Dentin adhesives used in this study were Scotchbond Multipurpose, Single Bond, SE Bond and Prompt L-Pop. Flat dentin surfaces adjacent to pulp chamber were created, then Ca(OH)2 and saline were mixed and applied on dentin surface of experimental group, then IRM was used to cover the mixture on dentin surface and the specimens were stored at 36.5degrees C for experiment period (7 days, 30 days). After removing IRM and Ca(OH)2, each dentin adhesives were treated on dentin surfaces. Composite resin (Z-250, 3M) was placed with 5 mm height and was light-cured for 20 seconds. After stored in distilled water for 24 hours, each dentin-composite bonded spicemen was embedded in epoxy resin and sectioned into 1.0 x 1.0 mm2 cross section composite-dentin beams. Specimen was mounted on zig of Universal testing machine and microTBS test was performed. SEM analysis was performed to examine the fractured surfaces. The results suggested that applying calcium hydroxide did not show significant difference in dentin bonding strength.


Asunto(s)
Adhesivos , Hidróxido de Calcio , Calcio , Cavidad Pulpar , Dentina , Agua
12.
Journal of Korean Academy of Conservative Dentistry ; : 208-221, 2007.
Artículo en Coreano | WPRIM | ID: wpr-140577

RESUMEN

The fracture toughness test is believed as a clinically relevant method for assessing the fracture resistance of the dentinal restoratives. The objectives of this study were to measure the fracture toughness (K1C) and microtensile bond strength of dentin-resin composite interface and compare their relationship for their use in evaluation of the integrity of the dentin-resin bond. A minimum of six short-rod specimens for fracture toughness test and fifteen specimens for microtensile bond strength test was fabricated for each group of materials used. After all specimens storing for 24 hours in distilled water at 37degrees C, they were tensile-loaded with an EZ tester universal testing machin. Statistical analysis was performed using ANOVA and Tukey's test at the 95% confidence level, Pearson's coefficient was used to verify the correlation between the mean of fracture toughness and microtensile bond strength. FE-SEM was employed on fractured surface to describe the crack propagation. Fracture toughness value of Clearfil SE Bond (SE) was the highest, followed by Adper Single Bond 2 (SB), OptiBond Solo (OB), ONE-STEP PLUS (OS), ScotchBond Multi-purpose (SM) and there was significant difference between SE and other 4 groups (p 0.05). Microtensile bond strength of SE was the highest, followed by SB, OB, SM, OS and OS only showed significant lower value (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. FE-SEM examination revealed that dentin bonding agent showed different film thickness and different failure pattern according to the film thickness. From the limited results of this study, it was noted that there was statistically no correlation between K1C and microTBS. We can conclude that for obtaining the reliability of bond strength test of dentin bonding agent, we must pay more attention to the test procedure and its profound scrutiny.


Asunto(s)
Dentina , Agua
13.
Journal of Korean Academy of Conservative Dentistry ; : 208-221, 2007.
Artículo en Coreano | WPRIM | ID: wpr-140576

RESUMEN

The fracture toughness test is believed as a clinically relevant method for assessing the fracture resistance of the dentinal restoratives. The objectives of this study were to measure the fracture toughness (K1C) and microtensile bond strength of dentin-resin composite interface and compare their relationship for their use in evaluation of the integrity of the dentin-resin bond. A minimum of six short-rod specimens for fracture toughness test and fifteen specimens for microtensile bond strength test was fabricated for each group of materials used. After all specimens storing for 24 hours in distilled water at 37degrees C, they were tensile-loaded with an EZ tester universal testing machin. Statistical analysis was performed using ANOVA and Tukey's test at the 95% confidence level, Pearson's coefficient was used to verify the correlation between the mean of fracture toughness and microtensile bond strength. FE-SEM was employed on fractured surface to describe the crack propagation. Fracture toughness value of Clearfil SE Bond (SE) was the highest, followed by Adper Single Bond 2 (SB), OptiBond Solo (OB), ONE-STEP PLUS (OS), ScotchBond Multi-purpose (SM) and there was significant difference between SE and other 4 groups (p 0.05). Microtensile bond strength of SE was the highest, followed by SB, OB, SM, OS and OS only showed significant lower value (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. FE-SEM examination revealed that dentin bonding agent showed different film thickness and different failure pattern according to the film thickness. From the limited results of this study, it was noted that there was statistically no correlation between K1C and microTBS. We can conclude that for obtaining the reliability of bond strength test of dentin bonding agent, we must pay more attention to the test procedure and its profound scrutiny.


Asunto(s)
Dentina , Agua
14.
Journal of Korean Academy of Conservative Dentistry ; : 236-247, 2007.
Artículo en Coreano | WPRIM | ID: wpr-140573

RESUMEN

The purpose of this study was to evaluate the effects of cyanate methacylate on the shear bond strengths to bovine dentin surfaces as a dentin primers. Seven experimental adhesives were made with different mass fraction of Isocyanatoetylmethacrylate (IEM), 40wt% HEMA (Wako Pure Chemical Industries Osaka, Japan), 0.6% camphoroquinone, 0.4% amine and ethanol as balance. dentin bonding agents (0, 2, 4, 6, 8, 10, 12%) were made and applied on the surface of bovine dentin specimens of 7 experimental groups. Shear bond strengths were measured using a universal testing machine (Instro 4466). To identify the ratio and modes of cohesive failures, microscopic examinationn was performed. The ultra-structure of resin tags were observed under scanning electron microscope. The results were as follows ; 1) A higher shear bond strengths (33.62 MPa) in group 8% of Cyanate methacrylate to dentin were found, but there were no statistically significancy between Groups (p > 0.05). 2) The higher ratio of cohesive failures mode in group 2, 6, an 10% could be seen than that in any other groups. 3) A shorter resin tags were observed in all experimental groups. This could be resulted that the preventing from the cyanate methacrylate penetrate into dentin owing to reacting it with dentin collagen. Therefore the resin tags were shorter in lengths. Whether the higher bonding strengths of dentin bonding agents can be affected was not been assured with statistic results. The results indicated that the relation between tensile strengths of the dentin adhesives to bovine dentin and resin tags formed into the dentin could not affected. The main reason of increasing the shear bond strength to bovine dentin in experimental groups could not be assured.


Asunto(s)
Adhesivos , Industria Química , Colágeno , Dentina , Recubrimientos Dentinarios , Etanol , Resistencia a la Tracción
15.
Journal of Korean Academy of Conservative Dentistry ; : 236-247, 2007.
Artículo en Coreano | WPRIM | ID: wpr-140572

RESUMEN

The purpose of this study was to evaluate the effects of cyanate methacylate on the shear bond strengths to bovine dentin surfaces as a dentin primers. Seven experimental adhesives were made with different mass fraction of Isocyanatoetylmethacrylate (IEM), 40wt% HEMA (Wako Pure Chemical Industries Osaka, Japan), 0.6% camphoroquinone, 0.4% amine and ethanol as balance. dentin bonding agents (0, 2, 4, 6, 8, 10, 12%) were made and applied on the surface of bovine dentin specimens of 7 experimental groups. Shear bond strengths were measured using a universal testing machine (Instro 4466). To identify the ratio and modes of cohesive failures, microscopic examinationn was performed. The ultra-structure of resin tags were observed under scanning electron microscope. The results were as follows ; 1) A higher shear bond strengths (33.62 MPa) in group 8% of Cyanate methacrylate to dentin were found, but there were no statistically significancy between Groups (p > 0.05). 2) The higher ratio of cohesive failures mode in group 2, 6, an 10% could be seen than that in any other groups. 3) A shorter resin tags were observed in all experimental groups. This could be resulted that the preventing from the cyanate methacrylate penetrate into dentin owing to reacting it with dentin collagen. Therefore the resin tags were shorter in lengths. Whether the higher bonding strengths of dentin bonding agents can be affected was not been assured with statistic results. The results indicated that the relation between tensile strengths of the dentin adhesives to bovine dentin and resin tags formed into the dentin could not affected. The main reason of increasing the shear bond strength to bovine dentin in experimental groups could not be assured.


Asunto(s)
Adhesivos , Industria Química , Colágeno , Dentina , Recubrimientos Dentinarios , Etanol , Resistencia a la Tracción
16.
Journal of Korean Academy of Conservative Dentistry ; : 426-436, 2007.
Artículo en Inglés | WPRIM | ID: wpr-67030

RESUMEN

The objective of this study is to evaluate the effect of an additional application of bonding resin on the bond strength of resin luting cements in both the light-cure (LC) and self-cure (SC) modes by means of the microTBS tests. Three combinations of One-Step Plus with Choice, Single Bond with Rely X ARC, and One-Up Bond F with Bistite II were used. D/E resin and Pre-Bond resin were used for the additional application. Twelve experimental groups were made. Three mandibular 3rd molars were used in each group. Indirect composite blocks were cemented on the tooth surface. 1 x 1 mm2 dentin-composite beam for microTBS testing were made and tested. When total-etching dentin adhesives were used, an additional application of the bonding resin increased the bond strength (P 0.05). In conclusion, the results suggest that an additional application of the bonding resin increases bond strength and enhances quality of bonding when using total-etching dentin adhesives.


Asunto(s)
Adhesivos , Dentina , Permeabilidad de la Dentina , Diente Molar , Cementos de Resina , Diente
17.
Journal of Korean Academy of Conservative Dentistry ; : 445-458, 2007.
Artículo en Coreano | WPRIM | ID: wpr-67028

RESUMEN

The purpose of this study was to evaluate the bond strength of a new Single step system with different curing mode composites, and to evaluate the effect of the intermediate resins which have different hydrophilicity on bonding ability by means of the micro shear bond testing and TEM examination for the adhesive interface. The adhesive used in this study was an experimental single step system (Bisco Inc., Schaumburg, IL). Experimental groups were produced by using six kinds of intermediate resin having different hydrophilicity that was hydrophilic, hydrophobic and most hydrophobic resin and as filled or not after applying adhesive. Each experimental group was further divided into two subgroups whether the adhesive was light cured or not. Dual cured composite (Bis Core, Bisco Ltd., Schaumburg, IL) was placed on the adhesive layer as light cure or self cure mode. The results of bond strength were statistically analyzed using one way ANOVA and multiple comparisons are made using Tukey's test at alpha < 0.05 level. The results of this study were as follows; 1. The application of intermediate resin did not increase the bond strength for light cured composite. 2. The bond strength of an experimental adhesive with self cured composite was significantly increased by the application of intermediate resin layer. 3. The bond strength of adhesive was irrespective of the cure or not of itself before intermediate resin layer applied. 4. As applied hydrophilic resin layer was, the initial bond strength was higher than both hydrophobic and most hydrophobic one used but there was no significance. Using a single step adhesive with dual/self cured composite, the incompatibility between both of them should be solved by the application of intermediate hydrophobic resin to reduce the adhesive permeability. However, Single step adhesive can be used in the light cured composite restoration without any decrease of the initial bond strength.


Asunto(s)
Adhesivos , Interacciones Hidrofóbicas e Hidrofílicas , Permeabilidad
18.
Korean Journal of Oral and Maxillofacial Radiology ; : 103-110, 2007.
Artículo en Coreano | WPRIM | ID: wpr-134251

RESUMEN

PURPOSE: To examine the danger zone of mesial root of mandibular first molar of patient without extraction using CBCT(cone -beam computed tomography) to avoid the risk of root perforation. MATERIALS AND METHODS: 20 mandibular first molars without caries and restorations were collected. CT images were obtained by CBCT(PSR9000N TM, Asahi Roentgen Co., Japan), reformed and analyzed by V-work 5.0 (CyberMed Inc., Korea). Distance between canal orifice and furcation was measured. In cross sectional images at 3, 4 and 5 mm below the canal orifice, distal wall thickness of mesiobuccal canal (MB-D), distal wall thickness of mesiolingual canal (ML-D), distal wall thickness of central part (C-D), mesial wall thickness of mesiobuccal canal (MB-M) and mesial wall thickness of mesiolingual canal (ML-M) were measured. RESULTS: The mean distance between the canal orifice and the furcation of the roots is 2.40 mm. Distal wall is found to be thinner than mesial wall. Mean dentinal wall thickness of distal wall is about 1 mm. The wall thickness is thinner as the distance from the canal orifice is farther. But significant differences are not noted between 4 mm and 5 mm in MB-D and C-D. MB-D is thinner than ML-D although the differences is not significant. CONCLUSION: The present study confirmed the anatomical weakness of distal surface of the coronal part of the mesial roots of mandibular first molar by CBCT and provided an anatomical guide line of wall thickness during endodontic treatment.


Asunto(s)
Humanos , Tomografía Computarizada de Haz Cónico , Dentina , Diente Molar
19.
Korean Journal of Oral and Maxillofacial Radiology ; : 103-110, 2007.
Artículo en Coreano | WPRIM | ID: wpr-134250

RESUMEN

PURPOSE: To examine the danger zone of mesial root of mandibular first molar of patient without extraction using CBCT(cone -beam computed tomography) to avoid the risk of root perforation. MATERIALS AND METHODS: 20 mandibular first molars without caries and restorations were collected. CT images were obtained by CBCT(PSR9000N TM, Asahi Roentgen Co., Japan), reformed and analyzed by V-work 5.0 (CyberMed Inc., Korea). Distance between canal orifice and furcation was measured. In cross sectional images at 3, 4 and 5 mm below the canal orifice, distal wall thickness of mesiobuccal canal (MB-D), distal wall thickness of mesiolingual canal (ML-D), distal wall thickness of central part (C-D), mesial wall thickness of mesiobuccal canal (MB-M) and mesial wall thickness of mesiolingual canal (ML-M) were measured. RESULTS: The mean distance between the canal orifice and the furcation of the roots is 2.40 mm. Distal wall is found to be thinner than mesial wall. Mean dentinal wall thickness of distal wall is about 1 mm. The wall thickness is thinner as the distance from the canal orifice is farther. But significant differences are not noted between 4 mm and 5 mm in MB-D and C-D. MB-D is thinner than ML-D although the differences is not significant. CONCLUSION: The present study confirmed the anatomical weakness of distal surface of the coronal part of the mesial roots of mandibular first molar by CBCT and provided an anatomical guide line of wall thickness during endodontic treatment.


Asunto(s)
Humanos , Tomografía Computarizada de Haz Cónico , Dentina , Diente Molar
20.
Journal of Korean Academy of Conservative Dentistry ; : 169-178, 2006.
Artículo en Coreano | WPRIM | ID: wpr-174008

RESUMEN

This study was to verify that the combined application of NaOCl and EDTA was more effective in removal of smear layer than the application of NaOCl alone. Furthermore it was aimed to find out the optimal time for the application of EDTA. Thirty five single rooted teeth were cleaned and shaped. NaOCl solution was used as an irrigant during instrumentation. After instrumentation, root canals of the control group were irrigated with 5 ml of NaOCl for 2 minutes. 30 sec, 1 min, and 2 min group were irrigated with 5 ml of 17% EDTA for 30 sec, 1 min, and 2 min respectively. Then the roots were examined with scanning electron microscopy for evaluating removal of smear layer and erosion of dentinal tubule. The results were as follows; 1. The control group: The smear layer was not removed at all. 2. The other groups: 1) Middle(1/3): All groups showed almost no smear layer. And the erosion occurred more frequently as increasing irrigation time. 2) Apical(1/3): The cleaning effect of 2 min group was better than the others. The results suggest that 2 min application of 17% EDTA should be adequate to remove smear layer on both apical(1/3) and middle(1/3).


Asunto(s)
Cavidad Pulpar , Dentina , Ácido Edético , Microscopía Electrónica de Rastreo , Capa de Barro Dentinario , Diente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA