Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Braz. dent. j ; 24(6): 605-609, Nov-Dec/2013. tab, graf
Artículo en Inglés | LILACS | ID: lil-697654

RESUMEN

This in vitro study evaluated the influence of two devices for application of shear load in microshear tests on bond strength and fracture pattern of primary enamel and dentin. Eighty primary molars were selected and flat enamel (40 teeth sectioned mesio-distally) and dentin (40 teeth sectioned transversally) surfaces were obtained. Both surfaces were polished to standardize the smear layer. Two-step etch-and-rinse adhesive systems (Adper Single Bond and XP Bond) were used. Polyethylene tubes was placed over the bonded surfaces and filled with composite resin. The microshear testing was performed after storage in water (24 h/37 °C) using two devices for application of microshear loads: a notched rod (Bisco Shear Bond Tester) or a knife edge (Kratos Industrial Equipment). Failure modes were evaluated using a stereomicroscope. Bond strength data were subjected to ANOVA and chi-square test to compare the failure mode distributions (α=0.05). No significant differences were observed between the groups for dentin and enamel bond strength or fracture patterns (p>0.05). The predominant failure mode was adhesive/mixed. In conclusion, the devices for application of shear loads did not influence the bond strength values, regardless of adhesive system and substrate.


Este estudo in vitro avaliou a influência de dois dispositivos para aplicação de força de cisalhamento em testes de resistência de união ao microcisalhamento e no padrão de fratura em dentina e esmalte de dentes decíduos. Oitenta molares decíduos foram selecionados e superficies planas em esmalte (40 dentes seccionados no sentido mésio-distal) e dentina (40 dentes seccionados transversalmente) foram obtidas. Ambas as superficies foram abrasionadas para padronização da lama dentinária. Dois sistemas adesivos de condicionamento ácido prévio (Adper Single Bond e XP Bond) foram utilizados. Tubos de polietileno foram colocados sobre as superficies, nas quais já haviam sido aplicados os sistemas adesivos, e preenchidos com resina composta. O teste de resistência de união ao microcisalhamento foi realizado após armazenamento dos espécimes em água (24 h/37 °C) utilizando dois dispositivos para a aplicação das forças de cisalhamento: cisalha côncava (Bisco Shear Bond Tester) e cisalha plana (Kratos Industrial Equipment). O padrão de fratura foi avaliado usando estereomicroscópio. Os dados de resistência de união foram submetidos à ANOVA e o teste quiquadrado foi utilizado para comparar a distribuição dos padrões de fratura (α=0,05). Não foram observadas diferenças estatisticamente significantes entre os grupos, tanto para a resistência de união a dentina e esmalte quanto para o padrão de fratura (p>0,05). O modo de falha predominante foi adesiva/mista. Em conclusão, os dispositivos para aplicação de força de cisalhamento não influenciam os valores de resistência de união, independente do sistema adesivo e substrato.


Asunto(s)
Humanos , Recubrimiento Dental Adhesivo , Análisis del Estrés Dental/instrumentación , Recubrimientos Dentinarios/química , Cementos Dentales/química , Técnicas In Vitro , Ensayo de Materiales , Diente Molar , Resistencia al Corte , Diente Primario
2.
J. appl. oral sci ; 21(1): 80-84, 2013. tab
Artículo en Inglés | LILACS, BBO | ID: lil-685000

RESUMEN

Objectives: This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage. Material and Methods: The restorative systems Adper Single Bond 2/Filtek Z350 (ASB), Clearfil SE Bond/Z350 (CF), Adper SE Plus/Z350 (ASEP) and P90 Adhesive System/Filtek P90 (P90) were applied on flat dentin surfaces of 20 third molars (n=5). The restored teeth were sectioned perpendicularly to the bonding interface to obtain sticks (0.8 mm2) to be tested after 24 hours (24 h) and 6 months (6 m) of water storage, in a universal testing machine at 0.5 mm/min. The data was analyzed via two-way Analysis of Variance/Bonferroni post hoc tests at 5% global significance. Results: Overall outcomes did not indicate a statistical difference for the resin systems (p=0.26) nor time (p=0.62). No interaction between material × time was detected (p=0.28). Mean standard-deviation in MPa at 24 h and 6 m were: ASB 31.38 (4.53) and 30.06 (1.95), CF 34.26 (3.47) and 32.75 (4.18), ASEP 29.54 (4.14) and 33.47 (2.47), P90 30.27 (2.03) and 31.34 (2.19). Conclusions: The silorane-based system showed a similar performance to methacrylate-based materials on dentin. All systems were stable in terms of bond strength up to 6 month of water storage.


Asunto(s)
Humanos , Recubrimientos Dentinarios/química , Dentina/química , Metacrilatos/química , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Cementos Dentales/química , Ensayo de Materiales , Cementos de Resina/química , Propiedades de Superficie , Resistencia a la Tracción , Factores de Tiempo , Agua
3.
Braz. dent. j ; 23(5): 490-495, Sept.-Oct. 2012. ilus, tab
Artículo en Inglés | LILACS | ID: lil-660349

RESUMEN

The aim of this study was to evaluate the influence of microstructure and composition of basic alloys on their microshear bond strength (µSBS) to resin luting cement. The alloys used were: Supreme Cast-V (SC), Tilite Star (TS), Wiron 99 (W9), VeraBond II (VBII), VeraBond (VB), Remanium (RM) and IPS d.SIGN 30 (IPS). Five wax patterns (13mm in diameter and 4mm height) were invested, and cast in a centrifugal casting machine for each basic alloy. The specimens were embedded in resin, polished with a SiC paper and sandblasted. After cleaning the metal surfaces, six tygon tubes (0.5 mm height and 0.75 mm in diameter) were placed on each alloy surface, the resin cement (Panavia F) was inserted, and the excess was removed before light-curing. After storage (24 h/37°C), the specimens were subjected to µSBS testing (0.5 mm/min). The data were subjected to a one-way repeated measures analysis of variance and Turkey's test (α=0.05). After polishing, their microstructures were revealed with specific conditioners. The highest µSBS (mean/standard deviation in MPa) were observed in the alloys with dendritic structure, eutectic formation or precipitation: VB (30.6/1.7), TS (29.8/0.9), SC (30.6/1.7), with the exception of IPS (31.1/0.9) which showed high µSBS but no eutectic formation. The W9 (28.1/1.5), VBII (25.9/2.0) and RM (25.9/0.9) showed the lowest µSBS and no eutectic formation. It seems that alloys with eutectic formation provide the highest µSBS values when bonded to a light-cured resin luting cement.


O objetivo deste estudo foi avaliar a influência da microestrutura e da composição de ligas básicas quanto à resistência de união (RU) a um agente cimentante resinoso. Foram usadas as seguintes ligas: Supreme Cast-V (SC), Tilite Star (TS), Wiron 99 (W9), VeraBond II (VBII), VeraBond (VB), Remanium (RM) and IPS d.SIGN 30 (IPS). Cinco padrões em cera (13 mm de diâmetro e 4 mm de altura) para cada uma das ligas básicas foram incluídos e fundidos em uma máquina de fundição. As amostras foram então embutidas em resina, polidas com lixas e jateadas. Após a limpeza das superfícies, seis cilindros de tygon tube (0,5 mm de altura e 0,75 mm de diâmetro) foram colocados sobre a superficie da liga e preenchida com cimento resinoso (Panavia F), o excesso foi removido antes da fotoativação. Após armazenagem (24 h/37ºC), cada amostra foi ensaiada por microcisalhamento a 0,5 mm/min. Os dados foram tratados por análise de variância para e medidas repetidas e teste Tukey (α=0,05). Para avaliar a microesturutura, as mesmas amostras foram polidas e condicionadas com solução específica. Os valores mais altos da RU (média/desvio padrão em MPa) foram encontrados para as ligas com estrutura dendrítica, formação eutética e precipitados: VB (30,6/1,7), TS (29,8/0,9), SC (30,6/1,7), com exceção da IPS (31,1/0,9) que apresentou alto valor de RU, mas sem formação eutética. As ligas W9 (28,1/1,5), VBII (25,9/2,0) and RM (25,9/0,9) apresentaram os menores valores de RU e ausência de formação eutética. Pode-se inferir que os valores mais elevados de resistência de união ao cimento resinoso fotoativado ocorre com as ligas que apresentam formação de eutético.


Asunto(s)
Aleaciones Dentales/química , Recubrimiento Dental Adhesivo/métodos , Ensayo de Materiales/métodos , Cementos de Resina/química , Análisis de Varianza , Curación por Luz de Adhesivos Dentales , Resistencia al Corte
4.
Braz. oral res ; 26(3): 190-196, May-June 2012. ilus, tab
Artículo en Inglés | LILACS | ID: lil-622933

RESUMEN

The aim of the present study was to evaluate the tensile strength, elongation, microhardness, microstructure and fracture pattern of various metal ceramic alloys cast under different casting conditions. Two Ni-Cr alloys, Co-Cr and Pd-Ag were used. The casting conditions were as follows: electromagnetic induction under argon atmosphere, vacuum, using blowtorch without atmosphere control. For each condition, 16 specimens, each measuring 25 mm long and 2.5 mm in diameter, were obtained. Ultimate tensile strength (UTS) and elongation (EL) tests were performed using a Kratos machine. Vickers Microhardness (VM), fracture mode and microstructure were analyzed by SEM. UTS, EL and VM data were statistically analyzed using ANOVA. For UTS, alloy composition had a direct influence on casting condition of alloys (Wiron 99 and Remanium CD), with higher values shown when cast with Flame/Air (p < 0.05). The factors 'alloy" and 'casting condition" influenced the EL and VM results, generally presenting opposite results, i.e., alloy with high elongation value had lower hardness (Wiron 99), and casting condition with the lowest EL values had the highest VM values (blowtorch). Both factors had significant influence on the properties evaluated, and prosthetic laboratories should select the appropriate casting method for each alloy composition to obtain the desired property.


Asunto(s)
Aleaciones de Cromo/química , Técnica de Colado Dental , Aleaciones de Cerámica y Metal/química , Análisis de Varianza , Pruebas de Dureza , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Paladio/química , Estrés Mecánico , Propiedades de Superficie , Plata/química , Resistencia a la Tracción
5.
Braz. dent. j ; 23(1): 22-27, 2012. tab
Artículo en Inglés | LILACS | ID: lil-618000

RESUMEN

The aim of this study was to assess, using the DPPH assay, the antioxidant activity of several substances that could be proposed to immediately revert the problems caused by bleaching procedures. The percentage of antioxidant activity (AA percent) of 10 percent ascorbic acid solution (AAcidS), 10 percent ascorbic acid gel (AAcidG), 10 percent sodium ascorbate solution (SodAsS), 10 percent sodium ascorbate gel (SodAsG), 10 percent sodium bicarbonate (Bicarb), Neutralize® (NE), Desensibilize® (DES), catalase C-40 at 10 mg/mL (CAT), 10 percent alcohol solution of alpha-tocopherol (VitE), Listerine® (LIS), 0.12 percent chlorhexidine (CHX), Croton Lechleri (CL), 10 percent aqueous solution of Uncaria Tomentosa (UT), artificial saliva (ArtS) and 0.05 percent sodium fluoride (NaF) was assessed in triplicate by 2,2-diphenyl-1-picryl-hydrazyl-hydrate (DPPH) free radical assay. All substances exhibited antioxidant activity, except for CL. AAcidS, AAcidG and VitE exhibited the highest AA percent (p<0.05). On the contrary, CHX, NE, LIS and NaF showed the lowest AA percent (p<0.05). In conclusion, AAcidS, AAcidG, SodAsS, SodAsG and VitE presented the highest antioxidant activity among substances tested in this study. The DPPH assay provides an easy and rapid way to evaluate potential antioxidants.


O objetivo deste estudo foi avaliar, por meio do DPPH, a atividade antioxidante de substâncias que poderiam ser propostas para reverter de imediato os problemas causados pelos procedimentos de clareamento. A porcentagem de atividade antioxidante (AA por cento) da solução de acido ascórbico 10 por cento (AAcidS), gel de ácido ascórbico a 10 por cento (AAcidG), solução de ascorbato de sódio 10 por cento (SodAsS), gel de ascorbato de sódio 10 por cento (SodAsG), bicarbonato de sódio 10 por cento (Bicarb), Neutralize® (NE), Desensibilize® (DES), catalase C-40 10 mg/mL (CAT), solução alcoólica 10 por cento de alfa-tocoferol (VitE), Listerine® (LIS), clorexidina 0,12 por cento (CHX), CrotonLechleri (CL), solução aquosa 10 por cento de Uncaria Tomentosa (UT), saliva artificial (ArtS) e fluoreto de sódio 0,05 por cento (NaF) foi avaliada em triplicata pelo teste de radicais livres 2,2-diphenyl-1-picryl-hydrazyl-hydrate (DPPH). Todas as substâncias apresentaram atividade antioxidante, exceto a CL. AAcidS, AAcidG e VitE mostraram os maiores valores de AA por cento (p<0,05). Por outro lado, CHX, NE, LIS e NaF mostraram os valores mais baixos de AA por cento (p<0,05). Em conclusão, AAcidS, AAcidG, SodAsS, SodAsG e VitE apresentaram os mais altos valores de atividade antioxidante entre as substâncias testadas. O teste DPPH é um método rápido e fácil para avaliar o potencial antioxidante.


Asunto(s)
Humanos , Antioxidantes/química , Compuestos de Bifenilo/química , Depuradores de Radicales Libres/química , Picratos/química , Blanqueamiento de Dientes/efectos adversos , Análisis de Varianza , Indicadores y Reactivos , Espectrofotometría Ultravioleta , Soluciones/química
6.
J. appl. oral sci ; 19(3): 254-259, May-June 2011. graf, tab
Artículo en Inglés | LILACS | ID: lil-588132

RESUMEN

OBJECTIVE: To determine the pH over a period of 168 h and the ionic silver content in various concentrations and post-preparation times of aqueous silver nitrate solutions. Also, the possible effects of these factors on microleakage test in adhesive/resin restorations in primary and permanent teeth were evaluated. MATERIAL AND METHODS: A digital pHmeter was used for measuring the pH of the solutions prepared with three types of water (purified, deionized or distilled) and three brands of silver nitrate salt (Merck, Synth or Cennabras) at 0, 1, 2, 24, 48, 72, 96 and 168 h after preparation, and storage in transparent or dark bottles. Ionic silver was assayed according to the post-preparation times (2, 24, 48, 72, 96, 168 h) and concentrations (1, 5, 25, 50 percent) of solutions by atomic emission spectrometry. For each sample of each condition, three readings were obtained for calculating the mean value. Class V cavities were prepared with enamel margins on primary and permanent teeth and restored with the adhesive systems OptiBond FL or OptiBond SOLO Plus SE and the composite resin Filtek Z-250. After nail polish coverage, the permanent teeth were immersed in 25 percent or 50 percent AgNO3 solution and the primary teeth in 5 percent or 50 percent AgNO3 solutions for microleakage evaluation. ANOVA and the Tukey's test were used for data analyses (α=5 percent). RESULTS: The mean pH of the solutions ranged from neutral to alkaline (7.9±2.2 to 11.8±0.9). Mean ionic silver content differed depending on the concentration of the solution (4.75±0.5 to 293±15.3 ppm). In the microleakage test, significant difference was only observed for the adhesive system factor (p=0.000). CONCLUSIONS: Under the tested experimental conditions and based on the obtained results, it may be concluded that the aqueous AgNO3 solutions: have neutral/alkaline pH and service life of up to 168 h; the level of ionic silver is proportional to the concentration of the solution; even at 5 percent concentration, the solutions were capable of indicating loss of marginal seal in the composite restorations; the 3-step conventional adhesive system had better performance regarding microleakage in enamel on primary and permanent teeth.


Asunto(s)
Filtración Dental/diagnóstico , Recubrimientos Dentinarios/química , Líquidos Iónicos/química , Nitrato de Plata/química , Análisis de Varianza , Concentración de Iones de Hidrógeno , Inmersión , Ensayo de Materiales , Factores de Tiempo
7.
RGO (Porto Alegre) ; 59(1): 117-123, jan.-mar. 2011. ilus, graf
Artículo en Portugués | LILACS, BBO | ID: lil-588587

RESUMEN

O objetivo deste estudo foi revisar a literatura para evidenciar os aspectos científicos e técnicos envolvidos no selamento de lesões de cárie em superfícies oclusais e proximais. Após a análise dos artigos referenciados, encontrados a partir de busca eletrônica e manual, observou-se que há trabalhos estudando a possibilidade de paralisação da lesão oclusal e proximal com procedimentos não invasivos. Diversos estudos são discutidos e o passo a passo da técnica para selamento proximal é abordado. O selamento parece ser uma ferramenta eficaz na paralisação da lesão cariosa em superfícies proximais, o que vem a ser um ganho de estrutura dental sadia em relação às técnicas invasivas. Apesar deste procedimento se mostrar bastante promissor em superfícies proximais, outros estudos clínicos devem ser realizados.


This study reviewed the literature to evidence the scientific and technical aspects involved in sealing occlusal and proximal carious lesions. Many studies report that it is possible to arrest the progression of occlusal and proximal caries with noninvasive procedures. Thus, sealing may accomplish this effectively and preserve more dental tissue than traditional caries treatment methods. The technique used for sealing proximal caries is discussed step-by-step. This technique seems very promising for arresting caries progression in proximal surfaces but more studies are necessary since studies on the topic are few.


Asunto(s)
Recubrimientos Dentinarios/uso terapéutico , Caries Dental/terapia
8.
J. appl. oral sci ; 18(6): 591-598, Nov.-Dec. 2010. ilus, tab
Artículo en Inglés | LILACS | ID: lil-573729

RESUMEN

OBJECTIVES: The aims of this study were to evaluate the effect of resin composite (Filtek Z250 and Filtek Flow Z350) and adhesive system [(Solobond Plus, Futurabond NR (VOCO) and Adper Single Bond (3M ESPE)] on the microtensile (μTBS) and microshear bond strength (μSBS) tests on enamel, and to correlate the bond strength means between them. MATERIAL AND METHODS: Thirty-six extracted human molars were sectioned to obtain two tooth halves: one for μTBS and the other one for μSBS. Adhesive systems and resin composites were applied to the enamel ground surfaces and light-cured. After storage (37(0)C/24 h) specimens were stressed (0.5 mm/min). Fracture modes were analyzed under scanning electron microscopy. The data were analyzed using two-way ANOVA and Tukey's test (α=0.05). RESULTS: The correlation between tests was estimated with Pearson's product-moment correlation statistics (α =0.05). For both tests only the main factor resin composite was statistically significant (p<0.05). The correlation test detected a positive (r=0.91) and significant (p=0.01) correlation between the tests. CONCLUSIONS: The results were more influenced by the resin type than by the adhesives. Both microbond tests seem to be positive and linearly correlated and can therefore lead to similar conclusions.


Asunto(s)
Humanos , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Esmalte Dental/química , Recubrimientos Dentinarios/química , Técnicas In Vitro , Análisis de Varianza , Bisfenol A Glicidil Metacrilato/química , Análisis del Estrés Dental , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Metacrilatos/química , Resistencia al Corte , Resistencia a la Tracción
9.
Braz. oral res ; 24(3): 361-367, July-Sept. 2010. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-558752

RESUMEN

The objective of this study was to evaluate the effectiveness of a therapeutic sealant to arrest non-cavitated proximal carious lesion progression. The study population comprised 44 adolescents who had bitewing radiographs taken for caries diagnosis. Non-cavitated lesions extending up to half of dentin thickness were included in the sample. In the experimental group (n = 33), the proximal caries-lesion surfaces were sealed with an adhesive (OptiBond Solo, Kerr) after tooth separation. The control group (n = 11) received no treatment, except for oral hygiene instructions including use of dental floss. Follow-up radiographs were taken after one year and were analyzed in comparison with baseline radiographs. In a blind study setting, visual readings were performed by two examiners, blinded to whether the examined radiograph was baseline or follow-up, and whether it concerned a test or control lesion. The efficacy of sealing treatment was evaluated by the McNemar test (0.05). About 22 percent of the sealed lesions showed reduction, 61 percent showed no change and 16 percent showed progression. For the control lesions, the corresponding values were 27 percent, 36 percent and 36 percent respectively. The number of lesions that showed reduction and no changes were merged and therefore 83.3 percent of the sealed lesions and 63.6 percent of the control lesions were considered clinically successful. No statistical significance was detected (p > 0.05). In the course of 1 year, sealing proximal caries lesions was not shown to be superior to lesion monitoring.


Asunto(s)
Adolescente , Adulto , Humanos , Adulto Joven , Bisfenol A Glicidil Metacrilato/uso terapéutico , Caries Dental/terapia , Selladores de Fosas y Fisuras/uso terapéutico , Caries Dental , Recubrimientos Dentinarios/uso terapéutico , Estudios de Seguimiento , Procesamiento de Imagen Asistido por Computador , Reproducibilidad de los Resultados , Resultado del Tratamiento , Adulto Joven
10.
Clín. int. j. braz. dent ; 6(2): 192-201, abr.-jun. 2010. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-724741

RESUMEN

O objetivo deste trabalho é apresentar um caso clínico, assim como uma breve revisão de literatura, sobre a utilização de um gel de ascorbato de sódio a 10% como passo intermediário entre o clareamento dental e restaurações diretas com resina composta


The aim of this article is to present a case report and a brief literature review about the use of 10% sodium ascorbate gel as an intermediate step after tooth bleaching and before direct resin composite restorations


Asunto(s)
Humanos , Femenino , Adulto Joven , Antioxidantes , Recubrimientos Dentinarios , Blanqueamiento de Dientes
11.
Rev. Assoc. Paul. Cir. Dent ; 63(5): 402-408, set.-out. 2009.
Artículo en Portugués | LILACS, BBO | ID: biblio-874226

RESUMEN

Objetivo: Avaliar o desempenho de sistemas adesivos nacionais e importados, considerando durabilidade da união à dentina e a análise em microscopia eletrônica de varredura (MEV) como parâmetros de comparação. Materiais e Métodos: Foram selecionados três sistemas adesivos nacionais - Magic Bond DE [MB], Master Bond [MAB] and Self Etch Bond [SEB] e dois importados - Clearfil SE Bond [SE] and Adper Single Bond 2 [SB]. Superfícies planas de dentina, obtidas pelo seccionamento da face oclusal de 25 terceiros molares humanos (n=5), receberam a aplicação dos sistemas adesivos, seguindo as instruções dos respectivos fabricantes e foram restauradas com resina composta. Após 24 horas de armazenamento em água, os espécimes foram seccionados em forma de palitos (corpos de prova - cps), com área de secção transversal de 0,8 mm-. Metade dos cps obtidos foram imediatamente submetidos ao teste de microtração e os restantes, após seis meses de armazenamento. Os valores de resistência de união obtidos foram submetidos à análise de variância e teste de Tukey, com nível de significãncia de 5%. Para análise em MEV dois dentes foram preparados para cada sistema adesivo. Resu Itados: Os va lores de resistência de união dos sistemas adesivos naciona is fora m inferiores aos importados, especialmente após armazenamento (p<0,05). O MAB apresentou comportamento distinto, pois em 24 horas, apresentou valores de resistência de união similares ao SB. A análise em MEV evidenciou falhas na camada híbrida dos sistemas nacionais, exceto o MAB. Conclusão: The imported adhesive systems swoed ligher durability to dentin


Purpose: Evaluate national adhesive systems' performance compared to similar imported systems, considering dentin bond strength (immediate and after storage) and scanning electron microscopy (SEM). Materiais and Methods: Three Brazilian adhesives were selected - Magic Bond DE [MB], Master Bond [MAB] and Self Etch Bond [SEB] and two imported - Clearfil SE Bond [SE] and Adper Single Bond 2 [SB]. Adhesive systems were applied on flat dentin surfaces from 25 third human molars (n=5) according manufacturers' intructions. Beam-shaped microtensile specimens were prepared after 24 hours water storage (0.8 mm2 cross-sectional area]. Half of obtained beams were immediately submitted to microtensile test and the other one after 6 months water storage. Values were submitted to ANOVA and Tukev's test at significance levei of 5%. Two teeth were prepared for each material to SEM analysis. Results: Bond strength values for Brazilian adhesive systems were lower than imported systems, especially after storage (p<0.051, except for MAB that presented similar values to SB on 24h.ln SEM analysis, hybridization failures were observed for Brazilian systems, except for MAB. Conclusion: Dentin bond durability of Brazilian adhesive systems is lower than similar imported materiais


Asunto(s)
Humanos , Masculino , Femenino , Recubrimientos Dentinarios , Dentina/anatomía & histología , Microscopía Electrónica de Rastreo/métodos , Resistencia a la Tracción
12.
J. appl. oral sci ; 17(4): 315-325, July/Aug. 2009. ilus, tab
Artículo en Inglés | LILACS | ID: lil-521707

RESUMEN

OBJECTIVES: To assess the bond strength and the morphology of enamel after application of self-etching adhesive systems with different acidities. The tested hypothesis was that the performance of the self-etching adhesive systems does not vary for the studied parameters. MATERIAL AND METHODS: Composite resin (Filtek Z250) buildups were bonded to untreated (prophylaxis) and treated (bur-cut or SiC-paper) enamel surfaces of third molars after application of four self-etching and two etch-and-rinse adhesive systems (n=6/condition): Clearfil SE Bond (CSE); OptiBond Solo Plus Self-Etch (OP); AdheSe (AD); Tyrian Self Priming Etching (TY), Adper Scotchbond Multi-Purpose Plus (SBMP) and Adper Single Bond (SB). After storage in water (24 h/37°C), the bonded specimens were sectioned into sticks with 0.8 mm² cross-sectional area and the microtensile bond strength was tested at a crosshead speed of 0.5 mm/min. The mean bond strength values (MPa) were subjected to two-way ANOVA and Tukey's test (á=0.05). The etching patterns of the adhesive systems were also observed with a scanning electron microscope. RESULTS: The main factor adhesive system was statistically significant (p<0.05). The mean bond strength values (MPa) and standard deviations were: CSE (20.5±3.5), OP (11.3±2.3), AD (11.2±2.8), TY (11.1±3.0), SBMP (21.9±4.0) and SB (24.9±3.0). Different etching patterns were observed for the self-etching primers depending on the enamel treatment and the pH of the adhesive system. CONCLUSION: Although there is a tendency towards using adhesive systems with simplified application procedures, this may compromise the bonding performance of some systems to enamel, even when the prismless enamel is removed.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales , Esmalte Dental , Análisis de Varianza , Ensayo de Materiales
13.
J. appl. oral sci ; 15(6): 475-479, Nov.-Dec. 2007. tab
Artículo en Inglés | LILACS | ID: lil-471102

RESUMEN

The aim of this study was to evaluate the early and 12-month bond strength of two adhesive systems (Single Bond-SB and One Step-OS) applied to demineralized dentin (WH) and demineralized/NaOCl-treated dentin (H). Twenty flat dentin surfaces were exposed, etched, rinsed and slightly dried. For the H groups, a solution of 10 percent NaOCl was applied for 60 s, rinsed (15 s) and slightly dried. The adhesives were applied according to the manufacturer's instructions and composite resin crowns were incrementally constructed. After 24 h (water-37ºC), the specimens was sectioned in order to obtain resin-dentin sticks (0.8 mm²). The specimens were tested in microtensile (0.5 mm/min) immediately (IM) or after 12 months of water storage (12M). The data (MPa) were subjected to ANOVA and Tukey's test (a=0.05). Only the main factors adhesive and time were significant (p=0.004 and p=0.003, respectively). SB (42.3±9.1) showed higher bond strengths than OS (33.6±11.6). The mean bond strength for IM-group (42.5±8.7) was statistically superior to 12M (33.3±11.8). The use of 10 percent NaOCl, after acid etching, did not improve the immediate and the long-term resin-dentin bond strength.

14.
Clín. int. j. braz. dent ; 2(1): 54-59, jan.-mar. 2006. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-526009

RESUMEN

Para este estudo, seccionaram-se 20 molares permanentes hígidos, no sentido do longo eixo, a fim de obter 40 espécimes, que foram divididos em quatro grupos experimentais (n=10): Single Bond (SB), Clearfil SE Bond (SE), Magic Bond DE (MB) e Self-Etch Bond (SEB). Os sistemas adesivos foram aplicados, seguindo-se as recomendações dos fabricantes, sobre superfície dentinária plana, previamente preparada, e blocos de compósito foram construídos. Após 24 horas, os espécimes foram preparados para o teste de microtração (área de secção aproximada de 0,8mm2). Os valores médios obtidos (MPa) foram submetidos à análise de variância. Os resultados mostram que a resistência de união dos sistemas adesivos nacionais (MB e SEB) é inferior à dos outros sistemas (SB e SE).


Asunto(s)
Materiales Dentales , Dentina , Recubrimientos Dentinarios , Resistencia a la Tracción
15.
J. appl. oral sci ; 13(4): 377-381, Oct.-Dec. 2005. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-873247

RESUMEN

Este estudo avaliou os efeitos de métodos para envelhecimento na microinfiltração de um sistema adesivo usado para selar superfícies oclusais. Após o condicionamento com ácido, as superfícies de 60 dentes permanentes foram contaminadas com 1 mL de plasma e seladas com OptiBond dual cure, ativado pelo Optilux 501, no modo rampa. A amostra foi dividida em oito grupos experimentais e um grupo controle ou imediato O envelhecimento dos espécimes foi realizado por 20 dias a 5, 37, 55 e 5-55ºC (200 ciclos/dia) em contato com a água ou não. Após submeter os espécimes à técnica de infiltração com AgNO3, eles foram secionados duas vezes e os valores médios da penetração do corante foram tratados por análise de variância. Nenhum grupo apresentou vedamento hermético na interface, nem mesmo o grupo sem envelhecimento (imediato ou controle). O grupo que permaneceu a 5ºC sem contato com a água mostrou o menor grau de penetração (p=0,015) e a interação envelhecimento x água foi significante (p=0,033). Os resultados levam às seguintes conclusões: 1) todos os grupos mostram microinfiltração, inclusive o controle; 2) o grupo mantido a 5ºC sem contato com a água mostrou os menores valores de microinfiltração; 3) em contato com a água, as variações térmicas parecem não afetar o grau de penetração do corante


Asunto(s)
Filtración Dental , Recubrimientos Dentinarios , Selladores de Fosas y Fisuras , Materiales Dentales , Técnicas In Vitro , Ensayo de Materiales
16.
J. appl. oral sci ; 13(4): 377-381, Oct.-Dec. 2005. tab, graf
Artículo en Inglés | LILACS, BBO | ID: lil-423372

RESUMEN

Este estudo avaliou os efeitos de métodos para envelhecimento na microinfiltração de um sistema adesivo usado para selar superfícies oclusais. Após o condicionamento com ácido, as superfícies de 60 dentes permanentes foram contaminadas com 1 mL de plasma e seladas com OptiBond dual cure, ativado pelo Optilux 501, no modo rampa. A amostra foi dividida em oito grupos experimentais e um grupo controle ou imediato O envelhecimento dos espécimes foi realizado por 20 dias a 5, 37, 55 e 5-55°C (200 ciclos/dia) em contato com a água ou não. Após submeter os espécimes à técnica de infiltração com AgNO3, eles foram secionados duas vezes e os valores médios da penetração do corante foram tratados por análise de variância. Nenhum grupo apresentou vedamento hermético na interface, nem mesmo o grupo sem envelhecimento (imediato ou controle). O grupo que permaneceu a 5°C sem contato com a água mostrou o menor grau de penetração (p=0,015) e a interação envelhecimento x água foi significante (p=0,033). Os resultados levam às seguintes conclusões: 1) todos os grupos mostram microinfiltração, inclusive o controle; 2) o grupo mantido a 5ºC sem contato com a água mostrou os menores valores de microinfiltração; 3) em contato com a água, as variações térmicas parecem não afetar o grau de penetração do corante.


Asunto(s)
Filtración Dental , Recubrimientos Dentinarios , Técnicas In Vitro , Selladores de Fosas y Fisuras , Materiales Dentales , Ensayo de Materiales
17.
Braz. oral res ; 19(4): 243-248, Oct.-Dec. 2005. tab
Artículo en Inglés | LILACS | ID: lil-421123

RESUMEN

A redução da prevalência de cáries não ocorreu uniformemente para todas as superfícies dentárias. Como as superfícies oclusais ainda são as mais susceptíveis ao desenvolvimento de lesões, novos métodos de diagnóstico ainda estão sendo avaliados. Este estudo comparou um sistema de fluorescência a laser (DIAGNOdent – DD) com o método visual de Ekstrand na detecção de cárie oclusal. Um total de 57 terceiros molares com superfícies oclusais macroscopicamente intactas foram selecionados. Dois examinadores examinaram 110 sítios por inspecção visual (IV) e DD. Após dez dias da primeira mensuração, todos os dentes foram novamente avaliados pelos mesmos métodos. A extensão de cárie foi validada por exame histológico (40 X). Os dados foram analisados quanto a sensibilidade, especificidade, reprodutibilidade intra e interexaminador e área sob a curva ROC. O teste kappa demonstrou boa reprodutibilidade intra e interexaminadores para ambos os métodos. A IV e o DD apresentaram sensibilidade semelhante para ambos os examinadores, entretanto, a IV apresentou maior especificidade que o DD. A análise geral, através da área sob a curva ROC, mostrou que a IV teve um melhor desempenho que o DD. Concluiu-se que o critério visual proposto por Ekstrand é mais confiável para o diagnóstico de cáries oclusais. O DD deve ser considerado apenas como um coadjuvante no exame de cárie em superfícies oclusais.


Asunto(s)
Humanos , Dentición Permanente , Pruebas de Actividad de Caries Dental/normas , Caries Dental/patología , Rayos Láser , Tercer Molar/patología , Pruebas de Actividad de Caries Dental/instrumentación , Caries Dental , Preparación de la Cavidad Dental/métodos , Esmalte Dental/patología , Dentina/patología , Fluorescencia , Rayos Láser/normas , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Curva ROC , Propiedades de Superficie
18.
J. appl. oral sci ; 13(3): 265-268, July-Sept. 2005. tab
Artículo en Inglés | LILACS | ID: lil-416873

RESUMEN

OBJETIVO: A finalidade da presente investigacão foi avaliar a influência das dimensões dos corpos-de-prova (cp) e da superfície de irradiacão na resistência à flexão de uma resina composta (Heliomolar RO). MÉTODOS: As diversas dimensões adotadas - comprimento x largura x altura (mm) foram: 25x2x4; 25x2x2 (ISO 4049); 15x2x2; 10x2x2; 10x2x1. A fotoativacão foi realizada por 40 segundos a 600mW/cm2; três vezes ao longo dos cp de 25mm, duas vezes ao longo dos cp de 15mm e uma vez nos cp de 10mm de comprimento. Os corpos-de-prova de todas as dimensões foram ativados em ambas as superfícies, ou apenas em uma; neste caso a carga de ruptura era aplicada na face de irradiacão ou na oposta. RESULTADOS: Foi mostrado que a resistência à flexão não foi afetada pelo comprimento dos cp. Com a fotoativacão em ambas as superfícies, as resistências obtidas eram semelhantes nos diversos comprimentos. Independentemente do número de faces irradiadas, os cp com 1mm de altura apresentaram resistências semelhantes. Contudo, cp com 4mm de altura e irradiados apenas por um lado, alcancaram os menores valores. CONCLUSAO: Com o emprego de cp com dimensões menores são alcancados valores de resistência à flexão semelhante aos obtidos com cp padronizados (ISO 4049), com a vantagem de menor demanda de material e menor consumo de tempo (o menor comprimento dos cp requer apenas uma ativacão por lado).


Asunto(s)
Resinas Compuestas , Materiales Dentales
19.
Braz. oral res ; 19(1): 17-22, Jan.-Mar. 2005. tab
Artículo en Inglés | LILACS | ID: lil-403729

RESUMEN

O propósito deste estudo foi comparar dois sistemas adesivos (OptiBond FLTM e OptiBond SOLOTM) utilizados como material único para selar superfícies oclusais contaminadas com relação à infiltração marginal. Após condicionamento ácido, 56 dentes hígidos foram contaminados com 1 µl de plasma e aleatoriamente divididos em 8 grupos (n = 7). Os adesivos foram fotoativados por 30 s sob duas condições (Optilux VCL-403TM e VCL-500TM). Cada espécime foi exposto a um de dois tratamentos de envelhecimento: ciclos térmicos (4.000 x a 5-55°C por 60 s) mais ciclos mecânicos (225.000 x com carga de 83,3 N); ou ciclos térmicos, mecânicos e de pH (soluções mineralizante/desmineralizante). Os espécimes foram imersos em solução aquosa de AgNO3 a 50%, secionados, e a penetração do corante foi medida em imagem digitalizada. Usou-se ANOVA para determinar os principais efeitos dos fatores e suas interações. Os resultados indicaram diferença significante entre os adesivos (p < 0,05), sugerindo que o OptiBond FLTM apresenta um desempenho melhor com relação à microinfiltração e poderia ser indicado como material único para selamento em condições de umidade ou contaminação acidental.


Asunto(s)
Humanos , Bisfenol A Glicidil Metacrilato/uso terapéutico , Filtración Dental/prevención & control , Recubrimientos Dentinarios/uso terapéutico , Metacrilatos/uso terapéutico , Selladores de Fosas y Fisuras/uso terapéutico , Cementos de Resina/uso terapéutico , Análisis de Varianza , Ensayo de Materiales/métodos
20.
J. appl. oral sci ; 12(4): 307-311, Oct.-Dec. 2004. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: lil-392982

RESUMEN

O objetivo deste estudo foi avaliar o efeito de duas técnicas incrementais de inserção na infiltração de restaurações de resinas compostas com módulos de elasticidade distintos e contração de polimerização semelhante. Para isto, foram preparadas 80 cavidades Classe V (4x4x2 mm) em incisivos bovinos que foram restauradas de modo aleatório com Z-250 (Z) ou Durafill VS (D) + Single Bond em incrementos axiais (a) ou oblíquos (o). As restaurações foram divididas em dois grupos: Não Envelhecidas - N (4 h em água destilada a 37° C) e Envelhecidas ù E (1 semana de armazenagem em água a 37° C + 1000 x - 5°-55°C / 1 min de imersão). Os espécimes foram recobertos com duas camadas de esmalte cosmético de modo que apenas as margens das restaurações ficassem expostas ao nitrato de prata (2h) seguido de imersão em revelador (8h) sob luz fluorescente. Posteriormente, eles foram secionados duas vezes no sentido vestíbulo-lingual, as superfïcies expostas (4) foram digitalizadas (Vidcap) e a penetração do nitrato de prata medido (ImageLab) nas paredes incisal e gengival. Os dados foram analisados por análise de variância de três fatores (Resina, Técnica de Inserção e Envelhecimento) separadamente para as paredes incisal e gengival. Resina e Envelhecimento foram significativos. A resina composta de micropartículas mostrou maior infiltração que a híbrida. A técnica de inserção influenciou a infiltração marginal dependendo da resina e do emprego ou não de ciclos térmicos.


Asunto(s)
Animales , Bovinos , Resinas Compuestas , Filtración Dental , Elasticidad , Restauración Dental Permanente , Incisivo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA