Arq. bras. cardiol ; 111(1): 84-91, July 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-950185

RESUMEN

Abstract Background: Carotid sinus hypersensitivity (CSH) is a frequent finding in the evaluation of syncope. However, its significance in the clinical setting is still dubious. A new criterion was proposed by Solari et al. with a symptomatic systolic blood pressure (SBP) cut-off value of ≤ 85 mmHg to refine the vasodepressor (VD) response diagnosis. Objective: To determine and compare the response to carotid sinus massage (CSM) in patients with and without syncope according to standard and proposed criteria. Methods: CSM was performed in 99 patients with and 66 patients without syncope. CSH was defined as cardioinhibitory (CI) for asystole ≥ 3 seconds, or as VD for SBP decrease ≥ 50 mmHg. Results: No differences in the hemodynamic responses were observed during CSM between the groups, with 24.2% and 25.8% CI, and 8.1% and 13.6% VD in the symptomatic and asymptomatic groups, respectively (p = 0.466). A p value < 0.050 was considered statistically significant. During the maneuvers, 45 (45.45%) and 34 (51.5%) patients in the symptomatic and asymptomatic groups achieved SBP below ≤ 85 mmHg. Symptoms were reported especially in those patients in whom CSM caused a SBP decrease to below 90 mmHg and/or asystole > 2.5 seconds, regardless of the pattern of response or the presence of previous syncope. Conclusion: The response to CSM in patients with and without syncope was similar; therefore, CSH may be an unspecific condition. Clinical correlation and other methods of evaluation, such as long-lasting ECG monitoring, may be necessary to confirm CSH as the cause of syncope.


Resumo Fundamento: A hipersensibilidade do seio carotídeo (HSC) é um achado frequente na avaliação da síncope. Entretanto, o valor da resposta positiva é ainda incerto no contexto clínico. Novo critério diagnóstico para tentar refinar a resposta vasodepressora (VD) foi proposto por Solari et al. com determinação da queda sintomática da pressão arterial sistólica (PAS) a níveis ≤ 85 mmHg como ponto de corte. Objetivo: Determinar e comparar a resposta à massagem do seio carotídeo (MSC) em pacientes com e sem síncope de acordo com os critérios vigentes e propostos. Métodos: A MSC foi realizada em 99 pacientes com síncope e 66 pacientes sem síncope. A HSC foi definida como cardioinibitória (CI), se assistolia ≥ 3 segundos, ou VD, se queda da PAS ≥ 50 mmHg. Resultados: Não foram observadas diferenças na resposta hemodinâmica entre os grupos durante a MSC, com 24,2% e 25,8% de resposta CI, e 8,1% e 13,6% de resposta VD nos grupos sintomático e assintomático, respectivamente (p = 0,466). Considerou-se p < 0,05 estatisticamente significativo. Durante as manobras, 45 (45,45%) e 34 (51,5%) pacientes nos grupos sintomático e assintomático atingiram PAS ≤ 85 mmHg. Sintomas foram relatados principalmente por pacientes em que a MSC reduziu a PAS para menos de 90 mmHg e/ou causou assistolia > 2,5 segundos, independentemente do padrão da resposta ou história de síncope prévia. Conclusão: As respostas à MSC em pacientes com e sem síncope foram semelhantes. Portanto, a HSC pode ser uma condição inespecífica. A correlação clínica mais precisa e outros métodos para avaliação, como monitoramento por ECG de longa duração, podem ser necessários para confirmação da HSC como causa da síncope.


Asunto(s)
Humanos , Síncope/diagnóstico , Seno Carotídeo/fisiopatología , Síncope/fisiopatología
2.
Arq. bras. cardiol ; 88(3): 265-272, mar. 2007. tab, ilus, graf
Artículo en Portugués | LILACS | ID: lil-451726

RESUMEN

OBJETIVOS: Avaliar se a ablação com radiofreqüência é um procedimento eficiente para o tratamento das extra-sístoles da via de saída do ventrículo direito (EVSVD), e se resulta em melhora dos sintomas. MÉTODOS: Estudo prospectivo, com 30 pacientes consecutivos (idade média de 40±13 anos, 25 do sexo feminino), sem cardiopatia estrutural aparente, com EVSVD, muito freqüentes (densidade média de 1.263±593/h), sintomáticos por mais de 1 ano (média =74 meses) e refratários aos fármacos antiarrítmicos (3±1,7, incluindo os beta-bloqueadores), que foram submetidos à ablação com radiofreqüência. RESULTADOS: Após o primeiro procedimento, houve 23 sucessos iniciais (76,6 por cento) e 7 iniciais insucessos (23,4 por cento). Quatro pacientes tiveram recorrências, sendo que dois desses não se submeteram ao segundo procedimento. O segundo procedimento foi realizado em 9 pacientes (7 insucessos iniciais e 2 recorrências), e o sucesso ocorreu em 5 pacientes adicionais, sendo 1 caso por acesso epicárdico. A taxa de sucesso final foi de 80 por cento (24/30), e nenhuma complicação maior ocorreu. Após um seguimento médio de 14±6 meses, no grupo de sucesso final houve uma redução de mais de 90 por cento na densidade das extra-sístoles(24/24; p<0,0001) e resultante ausência de sintomas na maioria dos pacientes (23/24; p<0,001). CONCLUSÃO: A ablação com radiofreqüência é um tratamento seguro e eficaz para os pacientes com extra-sístoles persistentes e sintomáticas com morfologia do trato de saída do ventrículo direito.


OBJECTIVES: To evaluate if radiofrequency catheter ablation is an effective procedure for the treatment of right ventricular outflow tract premature ventricular contractions (RVOT-PVC) and ascertain if it results in an improvement of symptoms. METHODS: A prospective study with 30 consecutive patients (mean age 40 ± 13 years, 25 females), with no apparent structural cardiopathy, with very frequent (mean density of 1,263 ± 593/h) RVOT-PVC, symptomatic for more than one year (mean = 74 months) and resistant to antiarrhythmic drugs (3 ± 1.7, including beta-blockers), who underwent radiofrequency catheter ablation. RESULTS: After the first procedure, there were 23 initial successful cases (76.6 percent) and 7 initial failures (23.4 percent). Four patients experienced relapses, two of whom did not undergo the second procedure. The second procedure was carried out in 9 patients (7 initial failures and 2 relapses), and there was success in 5 additional patients, one of them by epicardial access. The final success rate was 80 percent (24/30), and there were no major complications. After a mean follow-up of 14 ± 6 months, in the successful group there was a reduction greater than 90 percent in density of premature ventricular contractions (PVC) (24/24; p<0.0001) and a resulting absence of symptoms in the majority of patients (23/24; p<0.001). CONCLUSION: Radiofrequency catheter ablation is a safe and effective treatment for patients with persistent and symptomatic PVC with RVOT morphology.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Ablación por Catéter/normas , Obstrucción del Flujo Ventricular Externo/cirugía , Complejos Prematuros Ventriculares/cirugía , Estudios de Seguimiento , Estudios Prospectivos , Recurrencia , Reoperación , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/complicaciones , Complejos Prematuros Ventriculares/complicaciones
3.
Arq. bras. cardiol ; 88(3): 273-278, mar. 2007.
Artículo en Portugués | LILACS | ID: lil-451727

RESUMEN

OBJETIVOS: Trabalho prospectivo, randomizado para comparar a eficácia e a segurança do cateter irrigado em relação ao cateter com eletrodo distal de 8 mm para ablação com radiofreqüência (RF) do flutter atrial. MÉTODOS: Em 52 pacientes consecutivos referidos para tratamento do flutter atrial típico, a ablação do istmo cavotricuspídeo (Ist-CT) foi realizada com cateter de irrigação fechada (n=26) ou com cateter de eletrodo distal de 8 mm (n=26). Os pulsos de RF foram aplicados ponto a ponto por 60 segundos com potência limitada a 50 w com o cateter irrigado e por controle de temperatura (60°C, 70 w) com cateter de 8 mm. O critério de fim do procedimento foi a obtenção de bloqueio bidirecional do Ist-CT. RESULTADOS: O bloqueio Ist-CT foi obtido em 98,1 por cento dos pacientes. O "crossover" ocorreu em quatro pacientes do grupo com cateter irrigado. Não se encontrou diferença estatística significante em relação aos parâmetros da ablação, tais como tempo total de aplicação de RF (591,1±309,0s vs 486,2±250,8s), duração do procedimento (86,4 ± 23,6 vs 78,1±22,5min) e tempo de fluoroscopia (17,0±6,7 vs 15,4±4,6min) entre os dois grupos. Durante seguimento médio de 10,6 meses, um paciente do grupo irrigado apresentou recorrência do flutter atrial típico. CONCLUSÃO: A ablação do Ist-CT resultou ser efetiva e segura para o controle do flutter atrial com ambas as técnicas empregadas (cateter com eletrodo distal de 8 mm e cateter irrigado). A complexidade técnica do cateter irrigado proporciona menor competitividade.


OBJECTIVES: Both ablation catheters with closed irrigated system and 8mm tip-catheters have been shown to be more effective for typical atrial flutter radiofrequency (RF) ablation when compared to conventional 4 mm tip catheter. Considering the differences in complexity and costs of both systems, a prospective study was designed to compare the efficacy and safety of cooled-tip and 8mm-tip catheters for atrial flutter ablation. METHODS: Fifty-two consecutive patients underwent RF ablation of cavotricupsid isthmus (CTI) for the treatment of typical atrial flutter, using catheter with closed irrigation system (n=26) or 8 mm-tip catheter (n=26). The RF pulses were applied point-by-point for 60 seconds, with power limited at 50 w for the irrigated catheter and by temperature control (60°C / 70 w) for the 8mm catheter. RESULTS: The CTI block was successfully performed in 98.1 percent. Four patients in the irrigated group needed to switch to the other group. There was no significant difference with regard to ablation parameters, such as total time of RF ablation (591.1±309.0s vs 486.2±250.8s), total procedure duration (86.4±23.6 vs 78.1±22.5min) and time of fluoroscopy (17.0±6.7 vs 15.4±4.6min). During follow-up of 10.6 months in average, one patient in the irrigated group had recurrence of typical atrial flutter. CONCLUSION: Efficacy and safety of CTI ablation was comparable between both techniques (irrigated catheter and 8mm-tip catheter). The complexity of irrigated catheter makes it less competitive.


Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Aleteo Atrial/cirugía , Ablación por Catéter/normas , Frío , Ablación por Catéter/instrumentación , Cateterismo/instrumentación , Cateterismo/normas , Técnicas Electrofisiológicas Cardíacas , Estudios de Seguimiento , Estudios Prospectivos , Recurrencia , Irrigación Terapéutica , Resultado del Tratamiento , Válvula Tricúspide/cirugía
4.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 14(3): 453-461, Maio-Jun. 2004. graf
Artículo en Portugués | LILACS | ID: lil-407463

RESUMEN

Os recentes avanços na área de genética em arritmias têm possibilitado a descoberta de novas síndromes clínicas em pacientes sem cardiopatia estrutural aparente. Uma das principais causas tem sido o desequilíbrio das correntes iônicas gerado a partir de defeitos genéticos, polimorfismos, intervenções terapêuticas ou anormalidades estruturais, que podem ocasionar vários fenótipos arritmogênicos, como arritmias cardíacas, síncope e morte súbita. Os estudos genéticos estão na sua curva de aprendizado e a lista de arritmias cardíacas e seus aspectos genéticos ainda está longe de ser concluída. Discutiremos neste capítulo as principais doenças do ritmo cardíaco que, até o momento, apresentam implicações com aspectos genéticos


Asunto(s)
Humanos , Arritmias Cardíacas , Canales Iónicos/fisiología , Canales Iónicos/genética , Genética/instrumentación , Genética/tendencias , Displasia Ventricular Derecha Arritmogénica/fisiopatología , Displasia Ventricular Derecha Arritmogénica/genética , Fibrilación Atrial/fisiopatología , Taquicardia Ventricular/fisiopatología
5.
In. Sociedade de Cardiologia do Estado de Säo Paulo. SOCESP: cardiologia. Rio de Janeiro, Atheneu, 1996. p.1076-88, ilus, tab.
Monografía en Portugués | LILACS | ID: lil-264070
SELECCIÓN DE REFERENCIAS