1.
Chinese Journal of Epidemiology ; (12): 210-212, 2003.
Artículo en Chino | WPRIM | ID: wpr-348877

RESUMEN

<p><b>OBJECTIVE</b>To test the sensitivity and specificity of alpha-fetoprotein (AFP) colloidal gold diagnostic strip as compared with RIA-AFP diagnostic kit.</p><p><b>METHODS</b>Double blind method was used to test sera from 426 healthy people and 1567 patients selected in two general hospitals and a cancer hospital. Each serum was measured by RIA-AFP and AFP colloidal gold diagnostic strip on the same day. RIA-AFP diagnostic results was identified as true positive or negative.</p><p><b>RESULTS</b>Among 426 healthy people, all the RIA-AFP test showed negative result (serum AFP concentration less than 25 IU/ml), but the AFP colloidal gold diagnostic strip had 1.88% false positive. When comparing the result from 1567 patients measured by RIA-AFP, the sensitivity and specificity of AFP colloidal gold diagnostic strip were 99.3%, and 97.2%, respectively. The crude correspondence rate between the two diagnostic regents was 97.6%.</p><p><b>CONCLUSION</b>AFP colloidal gold diagnostic strip showed very good result and could be used as a screening diagnostic kit in clinic and hospital settings.</p>


Asunto(s)
Humanos , Biomarcadores de Tumor , Sangre , Carcinoma Hepatocelular , Diagnóstico , Método Doble Ciego , Oro Coloide , Neoplasias Hepáticas , Diagnóstico , Radioinmunoensayo , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , alfa-Fetoproteínas