Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Biosci. j. (Online) ; 32(2): 550-559, mar./abr. 2016. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-965383

RESUMEN

To evaluate the cumulative enamel loss during bonding and debonding procedures of orthodontic metallic brackets and to analyze the enamel superficial roughness. Forty-seven maxillary first premolars were obtained for quantitative and qualitative analysis. For quantitative analysis, forty premolars were weighed at each stage of treatment and the equivalent thickness of enamel loss was measured. The amount of tooth mass loss in each stage was divided by the density value to obtain the corresponding enamel volume lost. Subsequently, these volumes were divided by a circular area with a diameter of 7 mm, thus obtaining the equivalent thickness of enamel loss. They were assessed under the following conditions: as sound enamel, after acid conditioning, following the removal of residual resin composite, after final polishing with high or low-speed, and with or without water refrigeration. A rugosimeter was used to obtain a graphic registration of the enamel superficial roughness before and after acid conditioning. The data were analyzed with the Quantikov software and the Shapiro Wilk's and Wilcoxon statistical tests were used to evaluate enamel superficial roughness. The one-way ANOVA followed by Bonferroni Post-Hoc tests were used to analyze the amount of enamel loss. For qualitative analysis, scanning electron microscopy (SEM) of the enamel surfaces was performed on seven premolars, one in each step. Acid conditioning significantly increased enamel surface roughness (p<0.01). Based on the dental mass weighed after each stage of evaluation, enamel loss was statistically significant in all stages (p<0.01). However, when the 4 different final polishing methods were compared, no statistically significant differences were registered regarding loss of mineralized structure (p=0.72). The SEM analysis revealed that the tungsten-carbide bur with water refrigeration and lowspeed rubber points caused less damage to the enamel. The greatest amount of enamel loss was due to acid conditioning. The losses relative to abrasion with composite removal or after the 4 polishing protocols were similar. Finally, none of the enamel surfaces was restored to their original aspects after bonding and debonding metallic brackets.


Determinar a perda de esmalte durante os procedimentos de colagem e descolagem de bráquetes ortodônticos e analisar a rugosidade superficial do esmalte. Quarenta e sete primeiros pré-molares superiores foram obtidos para análise quantitativa e qualitativa. Para a análise quantitativa, quarenta pré-molares foram pesados em cada uma das etapas do tratamento e a espessura equivalente do esmalte foi medida. A perda de massa em cada fase foi dividida pelo valor de densidade do esmalte para obter o volume correspondente. Em seguida, o volume foi dividido pela área circular de 7 mm de diâmetro, obtendo-se assim a espessura equivalente da perda de esmalte. Os dentes foram avaliados nas seguintes condições: esmalte íntegro, após condicionamento ácido, depois da remoção da resina remanescente e após o polimento final em alta e baixa rotação, com e sem refrigeração. Ainda foi utilizado um rugosímetro para obtenção dos registros gráficos de perfis da rugosidade superficial do esmalte antes e após o condicionamento ácido. Os dados foram analisados utilizando-se o software Quantikov, para determinação e comparação dos comprimentos dos registros obtidos antes e após o condicionamento ácido, o teste Shapiro Wilk e o Wilcoxon para rugosidade superificial do esmalte e, por fim, o ANOVA um fator seguido pelo Bonferroni Post-Hoc para perda de esmalte. Para a análise qualitativa, foi empregada a microscopia eletrônica de varredura nas superfícies de esmalte de sete pré-molares, um dente para cada etapa. O condicionamento ácido promoveu o aumento do comprimento do perfil de superfície do esmalte, ou seja, o aumento da rugosidade (p<0,01). Na avaliação da massa dos elementos dentários, percebeu-se que a perda de esmalte foi estatisticamente significante em todas as etapas do experimento (p<0,01). Entretanto, ao comparar os diferentes métodos de polimentos, verificou-se que não há diferença estatisticamente significante na perda de estrutura mineralizada (p=0,72). Na análise da microscopia eletrônica de varredura, a remoção da resina com broca carbide de tungstênio multilaminada com refrigeração e o polimento em baixa rotação sob refrigeração apresentaram menos dano ao esmalte. A maior perda de esmalte foi devida ao condicionamento ácido. As perdas referentes ao desgaste com a broca e o polimento são semelhantes e os 4 protocolos de polimento testados resultaram em diminuições similares na espessura do esmalte. Nenhuma das superfícies de esmalte foi restaurada ao seu aspecto original após a colagem e descolagem de bráquetes metálicos.


Asunto(s)
Soportes Ortodóncicos , Esmalte Dental , Pulido Dental
2.
Braz. j. oral sci ; 14(3): 209-213, July-Sept. 2015. graf
Artículo en Inglés | LILACS, BBO | ID: lil-770527

RESUMEN

Abstract Aim: To investigate whether the removal and reseating of the abutment influences the retention of Morse taper implant system. Methods: Two Morse taper implant systems were selected: Bicon Dental ImplantTM system (Bicon, LLC, Boston, MA, USA) and Kopp Implant(r) system (Kopp(r), Curitiba, PR, Brazil). In both systems, the abutment is connected to the implant with a locking taper. To seat the abutment, the same vertical force was applied in both systems. It was measured the compressive force necessary to engage effectively the locking taper connection and the tensile force to displace it. Results: The compressive force was determined by four activations in each abutment-implant set, and the sum of these forces was 21 N and 17 N in the BiconTM and Kopp(r) systems, respectively. Next, a tensile test was performed, revealing that the BiconTM system presented a 208 N resistance, whereas it was 194 N in the Kopp(r) system. Other three rounds of compression and tensile loads were applied, removing and reseating the abutment. We obtained the following tensile values: 367 N, 500 N and 756 N in the BiconTM System and 336 N, 360 N and 420 N in the Kopp(r) system. Conclusions: When the sets were subjected to repeated rounds of compressive and tensile forces, displacing and reseating the abutment, the tensile value increased.


Asunto(s)
Resistencia a la Tracción , Implantes Dentales , Fuerza Compresiva , Diseño de Implante Dental-Pilar
3.
ImplantNews ; 12(4): 427-430, 2015. ilus
Artículo en Portugués | LILACS, BBO | ID: lil-764280

RESUMEN

O presente trabalho teve como objetivo relatar um caso de reabilitação bucal de um paciente portador de displasia ectodérmica, através de próteses totais fixas aparafusadas sustentadas por implantes zigomáticos e convencionais. Os aspectos clínicos e radiográficos serão descritos juntamente com a sequência de tratamento realizada até a finalização do caso. Esse tipo de tratamento tem apresentado resultados satisfatórios.


This case reports on the use of total fixed implant-supported screwed prostheses with zygomatic and conventional implants in the treatment of a completely edentulous patient with anihidrotic ectodermal dysplasia. Clinical and radiographic aspects are demonstrated during treatment sequence. This kind of rehabilitation has presented satisfactory results.


Asunto(s)
Humanos , Masculino , Adulto , Displasia Ectodérmica , Rehabilitación Bucal , Anomalías Dentarias
4.
Pesqui. bras. odontopediatria clín. integr ; 15(1): 243-252, 2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-796369

RESUMEN

To assess the sealing capacity of different dental cements regarding apical microleakage on teeth with prefabricated posts. Material and Methods:Forty-eight single-rooted teeth were selectedand, after having their coronal part removed at 10mm standard, underwent endodontic cleaning and preparation. The space for the post was prepared with # 3 Largo bur at 7 mm standard value. The study included the following groups: Group I, post prefabricated with # 1 intracanal glass fiber cemented with zinc phosphate cement (n = 12); Group II, post prefabricated with # 1 intracanal glass fiber cemented with conventional glass ionomer cement, Vidrion C (n = 12); Group III, post prefabricated with # 1 intracanal glass fiber cemented with chemical action resin cement, Multilink (n = 12). Two groups of six teeth each were also included, one as negative control group and the other as positive control. After cementing, teeth were tested through a dual-chamber experimental model, using Enterococcus Faecalis for apical contamination. Results:The control groups behaved as expected: positive control group with total contamination in 11 days and negative control group without any contaminated specimen within observation time of 60 days. Group I showed microleakage in all specimens for up to 29 days (100%)...


Group II and Group III showed microleakage in 50 and 49 specimens (83.33% and 75%) respectively along the research time of 60 days. Group 1 showed microleakage in all specimens for up to 29 days (100%). Group 2 and Group 3 showed microleakage in 50 and 49 specimens (83.33% and 75%) respectively along the research time of 60 days. The Log-Rank test showed differences between Groups 1 and 2 (p<0.05) and between Groups 1and 3 (p<0.05). However, there was no difference between Groups 2 and 3 (p> 0.05). The results showed higher delay in bacterial infiltration in Groups 2 and 3 when compared to Group 1.Conclusion:No cement completely prevented infiltration during the experimental period. Zinc phosphate cement had the lowest apical sealing capacity while glass ionomer cement and resin cement showed similar results...


Asunto(s)
Humanos , Cementos Dentales/química , Cementos de Ionómero Vítreo , Filtración Dental , Ápice del Diente/microbiología , Brasil , Endodoncia/métodos
5.
ImplantNews ; 10(1): 31-38, 2013. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-731422

RESUMEN

Em algumas situações clínicas em que pacientes parcialmente edêntulos apresentam a indicação para prótese fixa de cinco elementos dentoimplantossuportada, o implante pode se tornar algumas vezes o pilar intermediário dessa prótese. Esse tipo de prótese deve ser feito com cautela, tendo em vista possíveis complicações biomecânicas, pelas diferenças de mobilidade entre dente e implante e pela diferença na absorção e na distribuição das cargas funcionais. O objetivo desse trabalho foi analisar, por meio do método dos elementos finitos (MEF), as tensões geradas em uma prótese fixa dentoimplantossuportada de cinco elementos, modelada pelo programa computacional Ansys Revisão 5.7, sendo composta por dois dentes como pilares terminais, dois pônticos e um implante como pilar intermediário unidos de forma rígida. Foi aplicada uma carga vertical com valor nominal de 100 Newtons (N), distribuída uniformemente nas superfícies oclusais dos dentes posteriores. Pôde-se observar em uma análise qualitativa que o maior deslocamento da prótese no sentido oclusogengival foi na região dos pônticos, com valor máximo de deslocamento de 6,4 micrometros (µm). A tensão equivalente de Von Mises SEQV foi de 77,4 Megapascal (MPa) notando uma distribuição de tensões semelhante por toda infraestrutura metálica, na região entre as coroas protéticas. Concluiu-se que a infraestrutura metálica rígida exerce papel fundamental na distribuição e absorção das tensões e no deslocamento do conjunto protético e o implante intermediário não atua como fulcro de uma alavanca Classe I.


In some clinical situations, partially edentulous patients can have indication for a five-element implant-supported prosthesis, with one of those implants being the pier abutment. This type of prosthesis should be constructed with caution, because of possible biomechanical uncertainties, due to different displacement behaviors and the distribution of the functional loads involved in the process. The aim of this work was to analyze by Finite Element Method (FEM) the global behavior of stresses and displacements involved in a tooth-implant-supported fixed prosthesis with five elements, having two teeth as terminal abutments, two bridges and an implant working as an intermediate abutment. The Ansys 5.7 program has been used as a computational tool. A nominal vertical load of 100 N has been applied, uniformly distributed, on the occlusive surfaces in the posterior teeth. It is possible to conclude, in a qualitative analysis, that the prosthesis showed a higher displacement in the occlusion-gingival direction of the bridges, with a value around 6,4 µm. The equivalent Von Misses stresses (SEQV) showed a maximum value of 77,4 MPa in the metallic bar among the prosthetic crowns. It can be concluded that the infra-structure has an important function in the distribution and absorption of stresses and displacements of the whole prosthetic set and the implant did not work as pier abutment.


Asunto(s)
Humanos , Implantación Dental , Dentadura Parcial Fija , Diente
6.
Dental press j. orthod. (Impr.) ; 17(2): 170-177, Mar.-Apr. 2012. ilus
Artículo en Inglés | LILACS | ID: lil-626385

RESUMEN

INTRODUCTION: Sliding mechanics is widely used during orthodontic treatment. One of the disadvantages of this mechanics is the friction generated at the bracket/archwire interface, which may reduce the amount of desired orthodontic movement obtained. Due to the application and great acceptance of this type of mechanics, the role of friction in Orthodontics has been of interest for both clinicians and scientists. OBJECTIVE: Therefore, this article discussed how friction affects orthodontic tooth movement, with an approach to its clinical implications as well as the evolution of dental materials and its properties regarding resistance to sliding.

7.
J. appl. oral sci ; 19(6): 655-661, Nov.-Dec. 2011. ilus, tab
Artículo en Inglés | LILACS | ID: lil-610883

RESUMEN

OBJECTIVES: In some clinical situations, dentists come across partially edentulous patients, and it might be necessary to connect teeth to implants. The aim of this study was to evaluate a metal-ceramic fixed tooth/implant-supported denture with a straight segment, located in the posterior region of the maxilla, when varying the number of teeth used as abutments. MATERIAL AND METHODS: A three-element fixed denture composed of one tooth and one implant (Model 1), and a four-element fixed denture composed of two teeth and one implant (Model 2) were modeled. A 100 N load was applied, distributed uniformly on the entire set, simulating functional mastication, for further analysis of the SEQV (Von Mises) principal stresses, which were compared with the flow limit of the materials. RESULTS: In a quantitative analysis, it may be observed that in the denture with one tooth, the maximum SEQV stress was 47.84 MPa, whereas for the denture with two teeth the maximum SEQV stress was 35.82 MPa, both located in the region between the pontic and the tooth. CONCLUSION: Lower stresses were observed in the denture with an additional tooth. Based on the flow limit of the materials, porcelain showed values below the limit of functional mastication.


Asunto(s)
Humanos , Pilares Dentales , Análisis del Estrés Dental , Prótesis Dental de Soporte Implantado/métodos , Análisis de Elementos Finitos , Fenómenos Biomecánicos , Fuerza de la Mordida , Implantes Dentales , Modelos Dentales , Dentadura Parcial Fija , Materiales Dentales/química , Módulo de Elasticidad , Ensayo de Materiales , Estrés Mecánico
8.
Dental press j. orthod. (Impr.) ; 16(1): 107-115, jan.-fev. 2011. ilus, graf, tab
Artículo en Portugués | LILACS | ID: lil-580321

RESUMEN

INTRODUÇÃO: o atrito gerado na interface braquete/fio durante a mecânica de deslizamento pode reduzir a eficiência da movimentação ortodôntica. O método de ligação do fio ao braquete exerce importante papel na determinação desse atrito. MÉTODOS: o presente estudo comparou a força de atrito gerada por quatro tipos de braquetes autoligáveis (Time®; Damon 2®; In-Ovation R® e Smart Clip®) com um grupo de braquetes ortodônticos convencionais (Dynalock®) associados a ligaduras elásticas tradicionais (Dispens-A-Stix®), que serviu como grupo controle. A força de atrito estático foi mensurada através da máquina universal de ensaios EMIC® DL 500 com dois fios de aço inoxidável com secção transversal 0,018" e 0,017" x 0,025". RESULTADOS: a análise de variância ANOVA e o teste de Tukey mostraram baixos níveis de atrito nos quatro braquetes autoligáveis associados ao fio 0,018" (P<0,05). Entretanto, os resultados observados quando os braquetes autoligáveis foram testados com fios 0,017" x 0,025" mostraram alta resistência ao deslizamento nos grupos de braquetes autoligáveis ativos.


INTRODUCTION: Friction generated at the bracket/archwire interface during sliding mechanics can reduce the efficiency of orthodontic movement. The ligation method employed to tie the archwire to the bracket plays an important role in determining this friction. METHODS: This study compared the frictional force generated by four different types of self-ligating brackets (Time™, Damon 2™, In-Ovation R™ and Smart Clip™) with a group of conventional orthodontic brackets (Dynalock™) that require the use of traditional elastomeric ligatures (ExDispens-A-Stix™), which served as the control group. Static friction force was measured using an EMIC DL™ 500 universal testing machine using stainless steel round 0.018-in and rectangular 0.017x0.025-in archwires. RESULTS: ANOVA and Tukey's test showed low levels of friction in the four self-ligating brackets in tests with the 0.018-in wire (P <0.05). However, the results noted when the self-ligating brackets were tested using 0.017x 0.025-in archwires showed high resistance to sliding in the self-ligating groups.


Asunto(s)
Aparatos Ortodóncicos , Fricción , Métodos de Anclaje en Ortodoncia , Soportes Ortodóncicos , Ortodoncia , Ortodoncia/métodos
9.
ImplantNews ; 7(3): 417-423, 2010.
Artículo en Portugués | LILACS, BBO | ID: lil-563046

RESUMEN

Os implantes osseointegrados utilizados para reabilitação de edentulismo total mostram elevado grau de previsibilidade terapêutica. Entretanto, surgiu a necessidade de extrapolar as alternativas de tratamento com implantes para pacientes parcialmente edêntulos. Diante disto, vários estudos têm sido direcionados para a possibilidade ou não de unir tais implantes a dentes naturais, visto que o comportamento biomecânico destas duas estruturas apresentam peculiaridades distintas. Foram construídos dois modelos visando a simulação do comportamento mecânico de uma prótese fixa de união rígida entre dente natural e implante osseointegrado, variando a quantidade de implantes e dentes envolvidos a partir dos métodos de elementos finitos (MEF). A partir da modelagem geométrica dos modelos utilizando meio computacional, obteve-se a geração automática da malha de elementos finitos. Foi aplicada uma carga nominal de 100 N, distribuída uniformemente nas superfícies oclusais de todo o conjunto protético. Na análise dos resultados, observou-se maior deslocamento do conjunto da prótese no modelo contendo dois dentes e um implante e a tensão máxima SEQV gerada foi de 35,82 MPa. Para o modelo contendo um dente e dois implantes a tensão máxima SEQV foi de 27,11 MPa. A união entre dente e implante é previsível mecanicamente. A colocação de implantes adicionais promove maior ancoragem para o conjunto protético.


Osseointegrated implants used for rehabilitation of totally edentulous patients show a high degree of predictability. However, there is a need to extrapolate treatment options with implants for partially edentulous patients. Several studies have been focused on the possibility or not for joining such implants to natural teeth as the biomechanical behavior of these two structures have distinct features. Two computerized models were designed to simulate the mechanical behavior of a fixed union between natural tooth and osseointegrated implant, varying the number of implants and teeth involved for finite element analysis (FEA). From the geometric modeling environment using computational models, we obtained the automatic generation of finite element mesh. A 100N nominal load was uniformly distributed on the occlusal surfaces of the whole prosthesis. Results showed greater displacement of the prosthetic joint in the model with two teeth and one implant, and the maximum SEQV stress generated was 35.82 MPa. For the model containing one tooth and two implants, the maximum SEQV stress was 27.11 MPa. The union between tooth and implant is mechanically predictable. The use of additional implants promotes greater anchorage to the prosthetic joint.


Asunto(s)
Arcada Parcialmente Edéntula/rehabilitación , Fenómenos Biomecánicos , Implantes Dentales
10.
J. appl. oral sci ; 17(5): 515-520, Sept.-Oct. 2009. ilus, graf
Artículo en Inglés | LILACS | ID: lil-531406

RESUMEN

OBJECTIVES: This study evaluated by three-dimensional finite element analysis the tensions generated by different disocclusion patterns (canine guide and bilateral balanced occlusion) in an implant-supported mandibular complete denture. MATERIAL AND METHODS: A three-dimensional model of implant-supported mandibular complete denture was fabricated according to the Brånemark protocol. A 5-element 3.75 x 13-mm screw-shape dental implant system was modeled for this study. The implants were located in the inter-mental foramen region with 3-mm-high prosthetic components joined by a nickel-chromium framework with 12-mm bilateral cantilever covered by acrylic resin and 12 acrylic denture teeth. SolidWorks® software was used before and after processing the simulations. The mechanical properties of the components were inserted in the model and a 15 N load was established in fixed points, in each one of the simulations. Data were collected in the entire nickel-chromium framework. The results were displayed three-dimensionally as color graphic scales. RESULTS: The canine guide generated greater tensions in the region of the first implant, while the bilateral balanced occlusion generated great tensions in the entire metallic framework. The maximum tension found in the simulation of the bilateral balanced occlusion was 3.22 fold higher than the one found in the simulation of the disocclusion in canine guide. CONCLUSION: The pattern of disocclusion in canine guide is the ideal for implant-supported mandibular complete denture.


Asunto(s)
Humanos , Oclusión Dental , Oclusión Dental Balanceada , Prótesis Dental de Soporte Implantado , Dentadura Completa Inferior , Resinas Acrílicas/química , Proceso Alveolar/fisiología , Fenómenos Biomecánicos , Gráficos por Computador , Simulación por Computador , Aleaciones de Cromo/química , Implantes Dentales , Bases para Dentadura , Diseño de Dentadura , Materiales Dentales/química , Módulo de Elasticidad , Análisis de Elementos Finitos , Imagenología Tridimensional , Modelos Biológicos , Mandíbula/fisiología , Estrés Mecánico , Diente Artificial , Titanio/química
11.
Braz. oral res ; 23(2): 182-189, 2009. ilus, graf
Artículo en Inglés | LILACS | ID: lil-522299

RESUMEN

A comparative and qualitative analysis of the tensions generated in the cantilever region of an implant-supported mandibular complete denture was conducted using the three-dimensional finite element method. The mechanical properties of the components were input in the model and a load of 15 N was applied in pre-determined points. In the first simulation, the load was applied on the occlusal surface of the first premolar. In the second simulation, it was applied on the first and second premolars. In the third simulation, it was applied on the first and second premolars and on the first molar. The different occlusion patterns produced similar tension distributions in the cantilever region, which followed a similar pattern in the three simulations. In all of the cases, the highest levels of tension were located in the region of the first implant. However, as the loads were dislocated distally, the tensions increased considerably. The more extensive the cantilever, the more compromised will be the infrastructure, the prosthetic components and the implants. Regardless of the length of the cantilever, the highest tensions will always be located in the region of the implant next to the load application point.


Asunto(s)
Oclusión Dental , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental , Dentadura Completa Inferior , Imagenología Tridimensional , Fenómenos Biomecánicos , Simulación por Computador , Cromo/química , Análisis de Elementos Finitos , Modelos Biológicos , Mandíbula/fisiología , Níquel/química , Estrés Mecánico , Titanio/química
12.
Arq. odontol ; 45(2): 61-66, 2009. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: lil-556545

RESUMEN

Adhesion failure between silicone resilient liner materials and denture base resin is a common problem found in clinical practice. Bond failure results in localized unhygienic conditions at the debonded regions and causes functional failure of the prosthesis. The aim of this study was to evaluate the tensile bond strength of 2 resilient liners (auto-polymerized silicone - Permafix® and heat-polymerized silicone - Permaflex®) under the influence of a residual monomer methylmethacrylate ([MMA]R) concentration. Two polymethyl methacrylate (PMMA) specimens were prepared by implementing brass dies by means of a 3 mm thick spacer in a denture flask. Specimens (20 X 10 X 3 mm) were made by processing the resilient liners against the polymerized PMMA blocks. After polymerization, the brass spacer was removed from the mold, the PMMAblocks were trimmed, and the bonding surfaces were smoothed. The PMMA blocks were placed back into the molds and resilient liners were packed into the space provided by the brass spacer, followed by trial packing and polymerization according to manufacturer instructions. Twenty specimens...


Falha na união entre reembasadores resilientes de silicone e base acrílica da prótese é um problema encontrado na prática clínica. A falha na união resulta em condições anti-higiênicas localizadas em regiões que apresentam descolamento, além de causar perda de função das próteses. O objetivo deste trabalho foi avaliar a resistência de união de 2 reembasadores resilientes de silicone (autopolimerizável - Permafix® and termopolimerizável - Permaflex®) sob a influência da concentração do monômero residual metilmetacrilato ([MMA]R). Duas amostras de polimetilmetacrilato (PMMA) foram obtidas por meio da inclusão de matrizes metálicas separadas por um espaçador com 3mm de espessura em mufla. As amostras (20 X 10 X 3 mm) foram obtidas processando o material resiliente contra os blocos de PMMA polimerizados. Após a polimerização, removeu-se o espaçador, submeteram-se os blocos ao processo de acabamento, sendo as superfícies de união alisadas. Os blocos foram recolocados no molde e o material resiliente condensado no local...


Asunto(s)
Alineadores Dentales/efectos adversos , Resinas Acrílicas/administración & dosificación , Metilmetacrilatos/administración & dosificación
13.
Arq. odontol ; 45(4): 178-183, 2009. ilus
Artículo en Portugués | LILACS, BBO | ID: lil-578244

RESUMEN

Este trabalho analisou, pelo método dos elementos finitos tridimensional (MEF 3D), as tensões geradas, na interface entre a resina acrílica e a infra-estrutura metálica, quando são aplicadas cargas funcionais na região de extremo distal livre, em uma prótese total inferior, implantossuportada. Foi desenvolvido um MEF 3D de uma prótese total implantossuportada, inferior, tipo protocolo de Branemark, com 12 mm de cantilever bilateral. O pacote do programa SolidWorks® foi utilizado no pré e pós processamento dos dados. Na primeira simulação, o carregamento foi aplicado na superfície oclusal do primeiro pré-molar, na segunda, no primeiro e no segundo pré-molares e, na terceira, no primeiro e segundo pré-molares e no primeiro molar. Os resultados obtidos puderam ser visualizados tridimensionalmente, por imagens, com escalas e gráficos, mostrando que o padrão de oclusão na região da extremidade distal livre gerou uma distribuição das tensões uniforme nas três simulações, com os maiores níveis de tensão localizados na região do primeiro implante, em todos os casos. Porém, conforme os carregamentos foram se deslocando para distal, as tensões aumentavam consideravelmente. Foi possível concluir que quanto mais extensa a extremidade distal livre, mais comprometida será a interface entre a resina acrílica e a infra-estrutura metálica, e independentemente do comprimento do extremo livre distal, as maiores tensões sempre se localizam na interface entre a resina acrílica e a infraestrutura metálica ao redor da região do implante localizado mais próximo à extremidade distal livre, do lado de trabalho.


Asunto(s)
Humanos , Masculino , Femenino , Prótesis Dental de Soporte Implantado , Dentadura Completa Inferior , Resinas Acrílicas/análisis , Análisis de Elementos Finitos , Fenómenos Biomecánicos , Oclusión Dental
14.
Rev. bras. odontol ; 65(2): 247-251, jul.-dez. 2008. tab
Artículo en Portugués | LILACS, BBO | ID: lil-541836

RESUMEN

Foram selecionados 45 incisivos centrais superiores extraídos de humanos, que após o preparo químico-mecânico, foram preenchidos com curativo de hidróxido de cálcio nos 5 mm apicais. Posteriormente, ao seccionamento das coroas, restaurações provisórias com pinos intracanal foram fixados com Dycal, Temp-Bond e Lysanda. Toda superfície externa das raízes e coroas foi impermeabilizada exceto 2 mm próximos à adaptação cervical. Após serem imersos em Rodamina B a 2% por 7 dias, os espécimes foram seccionados longitudinalmente e analisados com lupa estereomicroscópica com câmara digital. Os resultados foram tabulados e submetidos à análise estatística. Concluiu-se que nenhum dos cimentos testados foi capaz de impedir a infiltração do corante.


Asunto(s)
Humanos , Cementos Dentales/normas , Filtración Dental , Hidróxido de Calcio/uso terapéutico , Ensayo de Materiales , Incisivo
15.
ImplantNews ; 5(2): 127-132, mar.-abr. 2008. ilus, graf
Artículo en Portugués | LILACS, BBO | ID: lil-518299

RESUMEN

Este trabalho analisou, pelo método dos elementos finitos tridimensionais, as tensões geradas na resina acrílica e nos dentes artificiais, por diferentes padrões desoclusão (guia canino - GC e oclusão balanceada bilateral - OBB) em uma prótese total inferior, implanto-suportada. Foi desenvolvido um modelo tridimensional de uma prótese total implanto-suportada inferior, tipo protocolo de Brånemark. O pacote do programa SolidWorks foi utilizado no pré e pós-processamento dos dados. Os resultados obtidos puderam ser visualizados tridimensionalmente, por imagens, com escalas coloridas e gráficos, mostrando que o padrão de desoclusão em GC gera uma tensão maior na região de interface entre a infra-estrutura metálica e a resina acrílica, entre os três primeiros implantes, e na OBB as tensões foram altas em toda a interface entre a resina acrílica e a infra-estrutura metálica. A tensão máxima encontrada na simulação da OBB foi 3,22 vezes maior que a encontrada na simulação da desoclusão em GC. O padrão de desoclusão em guia canino é mais indicado para esse tipo de prótese.


Asunto(s)
Oclusión Dental , Implantes Dentales , Fenómenos Biomecánicos
16.
Arq. odontol ; 44(3): 19-24, 2008. ilus
Artículo en Portugués | LILACS, BBO | ID: lil-544404

RESUMEN

O articulador semi-ajustável tem o propósito de reproduzir as relações maxilomandibulares estáticas e, parcialmente, as dinâmicas. No entanto, parte destas características depende da qualidade da fabricação dos aparelhos. O objetivo foi aferir os componentes responáveis pela determinação do ângulo de Bennett (AB), da eminência articular (EA) e da distância intercondilar (DI) do articulador semi-ajustável (ASA) Dentflex...


Asunto(s)
Articuladores Dentales/clasificación , Registro de la Relación Maxilomandibular/métodos , Instrumentos Dentales
17.
J. appl. oral sci ; 14(5): 312-318, Sept.-Oct. 2006. tab
Artículo en Inglés | LILACS, BBO | ID: lil-447810

RESUMEN

With the aim of assessing the performance of Brazilian and imported glass ionomer cements (GIC) with regard to microleakage, 40 primary molars received two standard class II cavity preparations with margins in enamel. Twenty cavities were filled with Brazilian materials (Vidrion® R and Vidrion® R Caps) and the other 20 cavities were filled with imported materials (Fuji® IX and Fuji® IX GPFast capsule). All fillings were performed by a single operator according to the manufacturer's instructions. Teeth were immersed in 0.5 percent methylene blue and half-sectioned. Three independent calibrated examiners assessed microleakage using scores (0-3). Data were submitted to the Kruskal-Wallis statistical test and Wilcoxon analysis. High microleakage indexes were verified for all ionomer cements: 59.5 percent of the samples restored with Vidrion® R or Vidrion® R Caps and 83.4 percent of the samples restored with Fuji® IX or Fuji® IX GPFast capsule obtained the maximum score (3). The Brazilian ionomer cements presented less microleakage than imported cements, although this difference was only significant (p=0.003) among the encapsulated materials.


Buscando comparar o desempenho de 2 cimentos de ionômero de vidro (CIV) restauradores convencionais nacionais, mais acessíveis tanto financeiramente quanto por disponibilidade no mercado, ao desempenho de 2 CIV importados frente à microinfiltração, confeccionou-se preparos classe II com término cervical em esmalte em 40 molares decíduos hígidos. Vinte cavidades foram restauradas com os CIV nacionais (Vidrion® R e Vidrion® R Caps) e as demais com os importados (Fuji® IX e Fuji® IX GPFast), por um único operador. Os dentes foram impermeabilizados, imersos em azul de metileno 0,5 por cento e seccionados mesio-distalmente. A microinfiltração foi avaliada por 3 examinadores calibrados, em microscópio estereoscópico, através de escores (0-3). Foram utilizados os testes estatísticos de Kruskall-Wallis e de Wilcoxon. Verificou-se altos índices de microinfiltração para todos os CIV: 59,5 por cento das amostras restauradas com Vidrion® R ou Vidrion® R Caps e 83,4 por cento das amostras restauradas com Fuji® IX ou Fuji® IX GPFast obtiveram o escore máximo (3). Os CIV nacionais apresentaram menos microinfiltração que os CIV importados, embora essa diferença só tenha sido significativa (p=0,003) entre os materiais encapsulados.


Asunto(s)
Humanos , Niño , Filtración Dental , Cementos de Ionómero Vítreo , Técnicas In Vitro , Diente Primario , Materiales Dentales
18.
J. appl. oral sci ; 14(5): 312-318, Sept.-Oct. 2006. tab
Artículo en Inglés | LILACS, BBO | ID: biblio-873308

RESUMEN

Buscando comparar o desempenho de 2 cimentos de ionômero de vidro (CIV) restauradores convencionais nacionais, mais acessíveis tanto financeiramente quanto por disponibilidade no mercado, ao desempenho de 2 CIV importados frente à microinfiltração, confeccionou-se preparos classe II com término cervical em esmalte em 40 molares decíduos hígidos. Vinte cavidades foram restauradas com os CIV nacionais (Vidrion« R e Vidrion« R Caps) e as demais com os importados (Fuji« IX e Fuji« IX GPFast), por um único operador. Os dentes foram impermeabilizados, imersos em azul de metileno 0,5 por cento e seccionados mesio-distalmente. A microinfiltração foi avaliada por 3 examinadores calibrados, em microscópio estereoscópico, através de escores (0-3). Foram utilizados os testes estatísticos de Kruskall-Wallis e de Wilcoxon. Verificou-se altos índices de microinfiltração para todos os CIV: 59,5 por cento das amostras restauradas com Vidrion« R ou Vidrion« R Caps e 83,4 por cento das amostras restauradas com Fuji« IX ou Fuji« IX GPFast obtiveram o escore máximo (3). Os CIV nacionais apresentaram menos microinfiltração que os CIV importados, embora essa diferença só tenha sido significativa (p=0,003) entre os materiais encapsulados.


Asunto(s)
Humanos , Niño , Filtración Dental , Cementos de Ionómero Vítreo , Diente Primario , Materiales Dentales , Técnicas In Vitro
19.
JBC j. bras. clin. odontol. integr ; 10(54): 275-281, jul.-set. 2006. CD-ROM
Artículo en Portugués | LILACS, BBO | ID: biblio-873375

RESUMEN

Há muito tempo, a microinfiltração vem sendo considerada uma das principais causas de falhas nas restaurações dentais, podendo provocar sensibilidade pós-operatória, descoloração ou manchamento marginal, lesão de cárie recorrente, deterioração do material restaurador, injúria pulpar e até reinfectar canais radiculares previamente tratados. No entanto, com a afirmação da filosofia preventiva e de promoção de saúde, têm surgido questionamentos a respeito da real importância clínica da microinfiltração. Este estudo apresenta uma revisão de literatura sobre o tema, relacionando causas, efeitos e estado atual das pesquisas para três materiais restauradores: resina composta, amálgama de prata e cimento de ionômero de vidro e constata que não é possível eliminar totalmente a microinfiltração para nenhum deles. Dentre os materiais citados, a resina composta parece ser o mais crítico. Existem artifícios para controlar a microinfiltração e seus efeitos, sendo a promoção da saúde bucal o mais eficiente


Asunto(s)
Resinas Compuestas , Caries Dental , Filtración Dental , Amalgama Dental , Materiales Dentales , Cementos de Ionómero Vítreo
20.
Pesqui. odontol. bras ; 16(4): 349-354, out.-dez. 2002. tab, graf
Artículo en Portugués | LILACS, BBO | ID: lil-327309

RESUMEN

Este estudo teve como objetivo avaliar a correlaçäo entre grau de conversäo e microdureza em resinas compostas, e o efeito do conteúdo de partículas e do tipo de unidade fotoativadora sobre esses parâmetros. Três resinas compostas (Artglass®, Solidex® e Zeta LC®) foram polimerizadas em três diferentes unidades laboratoriais (UniXS®, Solidilite® e unidade Experimental). Para cada material, quinze corpos-de-prova foram confeccionados em uma matriz metálica, e submetidos às análises do grau de conversäo, através de espectroscopia de infravermelho, e da microdureza. O conteúdo de partículas inorgânicas foi determinado por análise termogravimétrica (TGA). O comportamento conjunto das variáveis - grau de conversäo e microdureza - foi medido através do coeficiente de correlaçäo de Pearson. Para a resina Artglass®, o grau de conversäo variou de 37,5 por cento a 79,2 por cento, com valores de microdureza de 32,4 a 50,3 (r=0,904). Para a resina Solidex®, o grau de conversäo variou de 41,2 por cento a 60,4 por cento, com valores de microdureza de 33,3 a 44,1 (r=0,707). Para a resina Zeta LC®, os valores de conversäo e microdureza foram, respectivamente, de 62,0 por cento a 78,0 por cento e de 22,6 a 33,6 (r=0,710). Concluiu-se que o uso das diferentes unidades resultou em variaçöes dos valores de conversäo em funçäo das características específicas de cada unidade. Para cada material, uma forte correlaçäo entre conversäo e microdureza foi observada. Além disso, quando materiais diferentes foram comparados, observou-se que o conteúdo de partículas inorgânicas afetou diretamente os valores de microdureza, näo interferindo no grau de conversäo


Asunto(s)
Resinas Compuestas , Partículas Inorgánicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA