RESUMEN
Purpose@#Clinical prognostic criteria using preoperative factors were not developed for post–neoadjuvant therapy (NAT) surgery of pancreatic ductal adenocarcinoma (PDAC). We aimed to identify preoperative factors associated with overall survival (OS) in PDAC patients who underwent post-NAT curative-intent surgery and develop risk stratification criteria. @*Materials and Methods@#Consecutive PDAC patients who underwent post-NAT curative-intent surgeries between 2007 and 2020 were retrospectively analyzed. Demographic, laboratory, surgical, and histopathologic variables were collected. Baseline, preoperative, and interval changes of computed tomography (CT) findings proposed by the Society of Abdominal Radiology and the American Pancreatic Association were analyzed. Cox proportional hazard analysis was used to select preoperative variables associated with OS. We developed risk stratification criteria composed of the significant preoperative variables, i.e., post-NAT response criteria. We compared the discrimination performance of post-NAT response criteria with that of post-NAT pathological (yp) American Joint Cancer Committee TNM staging system. @*Results@#One hundred forty-five PDAC patients were included. Stable or increased tumor size on CT (hazard ratio [HR], 2.58; 95% confidence interval [CI], 1.58 to 4.21; p < 0.001) and elevated preoperative carbohydrate antigen 19-9 (CA19-9) level (HR, 1.98; 95% CI, 1.11 to 3.55; p=0.021) were independent factors of OS. The OS of the patient groups stratified by post-NAT response criteria which combined changes in tumor size and CA19-9 showed significant difference (p < 0.001). Such stratification was comparable to ypTNM staging in discrimination performance (difference of C-index, 0.068; 95% CI, –0.012 to 0.142). @*Conclusion@#“Any degree of decrease in tumor size on CT” and CA19-9 normalization or staying normal were independent favorable factors of OS. The combination of the two factors discriminated OS comparably to ypTNM staging.
RESUMEN
Objective@#In Korea, radiology has been positioned towards the early adoption of artificial intelligence-based software as medical devices (AI-SaMDs); however, little is known about the current usage, implementation, and future needs of AI-SaMDs.We surveyed the current trends and expectations for AI-SaMDs among members of the Korean Society of Radiology (KSR). @*Materials and Methods@#An anonymous and voluntary online survey was open to all KSR members between April 17 and May 15, 2023. The survey was focused on the experiences of using AI-SaMDs, patterns of usage, levels of satisfaction, and expectations regarding the use of AI-SaMDs, including the roles of the industry, government, and KSR regarding the clinical use of AI-SaMDs. @*Results@#Among the 370 respondents (response rate: 7.7% [370/4792]; 340 board-certified radiologists; 210 from academic institutions), 60.3% (223/370) had experience using AI-SaMDs. The two most common use-case of AI-SaMDs among the respondents were lesion detection (82.1%, 183/223), lesion diagnosis/classification (55.2%, 123/223), with the target imaging modalities being plain radiography (62.3%, 139/223), CT (42.6%, 95/223), mammography (29.1%, 65/223), and MRI (28.7%, 64/223). Most users were satisfied with AI-SaMDs (67.6% [115/170, for improvement of patient management] to 85.1% [189/222, for performance]). Regarding the expansion of clinical applications, most respondents expressed a preference for AI-SaMDs to assist in detection/diagnosis (77.0%, 285/370) and to perform automated measurement/quantification (63.5%, 235/370). Most respondents indicated that future development of AI-SaMDs should focus on improving practice efficiency (81.9%, 303/370) and quality (71.4%, 264/370). Overall, 91.9% of the respondents (340/370) agreed that there is a need for education or guidelines driven by the KSR regarding the use of AI-SaMDs. @*Conclusion@#The penetration rate of AI-SaMDs in clinical practice and the corresponding satisfaction levels were high among members of the KSR. Most AI-SaMDs have been used for lesion detection, diagnosis, and classification. Most respondents requested KSR-driven education or guidelines on the use of AI-SaMDs.
RESUMEN
Objective@#This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. @*Materials and Methods@#A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. @*Results@#Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm2 vs. 0.92 cm2 for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48–72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. @*Conclusion@#Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.
RESUMEN
Purpose@#To assess the added value of radiomics models from preoperative chest CT in predicting the presence of spread through air spaces (STAS) in the early stage of surgically resected lung adenocarcinomas using multiple validation datasets. @*Materials and Methods@#This retrospective study included 550 early-stage surgically resected lung adenocarcinomas in 521 patients, classified into training, test, internal validation, and temporal validation sets (n=211, 90, 91, and 158, respectively). Radiomics features were extracted from the segmented tumors on preoperative chest CT, and a radiomics score (Rad-score) was calculated to predict the presence of STAS. Diagnostic performance of the conventional model and the combined model, based on a combination of conventional and radiomics features, for the diagnosis of the presence of STAS were compared using the area under the curve (AUC) of the receiver operating characteristic curve. @*Results@#Rad-score was significantly higher in the STAS-positive group compared to the STAS-negative group in the training, test, internal, and temporal validation sets. The performance of the combined model was significantly higher than that of the conventional model in the training set {AUC: 0.784 [95% confidence interval (CI): 0.722–0.846] vs. AUC: 0.815 (95% CI: 0.759–0.872), p=0.042}. In the temporal validation set, the combined model showed a significantly higher AUC than that of the conventional model (p=0.001). The combined model showed a higher AUC than the conventional model in the test and internal validation sets, albeit with no statistical significance. @*Conclusion@#A quantitative CT radiomics model can assist in the non-invasive prediction of the presence of STAS in the early stage of lung adenocarcinomas.
RESUMEN
Purpose@#Lower-grade gliomas of histologic grades 2 and 3 follow heterogenous clinical outcomes, which necessitates risk stratification. This study aimed to evaluate whether diffusion-weighted and perfusion-weighted MRI radiomics allow overall survival (OS) prediction in patients with lower-grade gliomas and investigate its prognostic value. @*Materials and Methods@#In this retrospective study, radiomic features were extracted from apparent diffusion coefficient, relative cerebral blood volume map, and Ktrans map in patients with pathologically confirmed lower-grade gliomas (January 2012–February 2019). The radiomics risk score (RRS) calculated from selected features constituted a radiomics model. Multivariable Cox regression analysis, including clinical features and RRS, was performed. The models’ integrated area under the receiver operating characteristic curves (iAUCs) were compared. The radiomics model combined with clinical features was presented as a nomogram. @*Results@#The study included 129 patients (median age, 44 years; interquartile range, 37–57 years; 63 female): 90 patients for training set and 39 patients for test set. The RRS was an independent risk factor for OS with a hazard ratio of 6.01. The combined clinical and radiomics model achieved superior performance for OS prediction compared to the clinical model in both training (iAUC, 0.82 vs.0.72, p=0.002) and test sets (0.88 vs. 0.76, p=0.04). The radiomics nomogram combined with clinical features exhibited good agreement between the actual and predicted OS with C-index of 0.83 and 0.87 in the training and test sets, respectively. @*Conclusion@#Adding diffusion- and perfusion-weighted MRI radiomics to clinical features improved survival prediction in lowergrade glioma.
RESUMEN
Objective@#To quantitatively analyze the cardiac magnetic resonance imaging (CMR) characteristics of chemotherapy-related cardiac dysfunction (CTRCD) and explore their prognostic value for major adverse cardiovascular events (MACE). @*Materials and Methods@#A total of 145 patients (male:female = 76:69, mean age = 63.0 years) with cancer and heart failure who underwent CMR between January 2015 and January 2021 were included. CMR was performed using a 3T scanner (Siemens). Biventricular functions, native T1 T2, extracellular volume fraction (ECV) values, and late gadolinium enhancement (LGE) of the left ventricle (LV) were compared between those with and without CTRCD. These were compared between patients with mild-to-moderate CTRCD and those with severe CTRCD. Cox proportional hazard regression analysis was used to evaluate the association between the CMR parameters and MACE occurrence during follow-up in the CTRCD patients. @*Results@#Among 145 patients, 61 had CTRCD and 84 did not have CTRCD. Native T1, ECV, and T2 were significantly higher in the CTRCD group (1336.9 ms, 32.5%, and 44.7 ms, respectively) than those in the non-CTRCD group (1303.4 ms, 30.5%, and 42.0 ms, respectively; P = 0.013, 0.010, and < 0.001, respectively). They were not significantly different between patients with mild-to-moderate and severe CTRCD. Indexed LV mass was significantly smaller in the CTRCD group (65.0 g/m2 vs. 78.9 g/m2 ; P < 0.001). According to the multivariable Cox regression analysis, T2 (hazard ratio [HR]: 1.14, 95% confidence interval [CI]: 1.01–1.27; P = 0.028) and quantified LGE (HR: 1.07, 95% CI: 1.01–1.13; P = 0.021) were independently associated with MACE in the CTRCD patients. @*Conclusion@#Quantitative parameters from CMR have the potential to evaluate myocardial changes in CTRCD. Increased T2 with reduced LV mass was demonstrated in CTRCD patients even before the development of severe cardiac dysfunction. T2 and quantified LGE may be independent prognostic factors for MACE in patients with CTRCD.
RESUMEN
Objective@#To validate a simplified ordinal scoring method, referred to as modified length-based grading, for assessing coronary artery calcium (CAC) severity on non-electrocardiogram (ECG)-gated chest computed tomography (CT). @*Materials and Methods@#This retrospective study enrolled 120 patients (mean age ± standard deviation [SD], 63.1 ± 14.5 years; male, 64) who underwent both non-ECG-gated chest CT and ECG-gated cardiac CT between January 2011 and December 2021. Six radiologists independently assessed CAC severity on chest CT using two scoring methods (visual assessment and modified length-based grading) and categorized the results as none, mild, moderate, or severe. The CAC category on cardiac CT assessed using the Agatston score was used as the reference standard. Agreement among the six observers for CAC category classification was assessed using Fleiss kappa statistics. Agreement between CAC categories on chest CT obtained using either method and the Agatston score categories on cardiac CT was assessed using Cohen’s kappa. The time taken to evaluate CAC grading was compared between the observers and two grading methods. @*Results@#For differentiation of the four CAC categories, interobserver agreement was moderate for visual assessment (Fleiss kappa, 0.553 [95% confidence interval {CI}: 0.496–0.610]) and good for modified length-based grading (Fleiss kappa, 0.695 [95% CI: 0.636–0.754]). The modified length-based grading demonstrated better agreement with the reference standard categorization with cardiac CT than visual assessment (Cohen’s kappa, 0.565 [95% CI: 0.511–0.619 for visual assessment vs. 0.695 [95% CI: 0.638–0.752] for modified length-based grading). The overall time for evaluating CAC grading was slightly shorter in visual assessment (mean ± SD, 41.8 ± 38.9 s) than in modified length-based grading (43.5 ± 33.2 s) (P < 0.001). @*Conclusion@#The modified length-based grading worked well for evaluating CAC on non-ECG-gated chest CT with better interobserver agreement and agreement with cardiac CT than visual assessment.
RESUMEN
Purpose@#Artificial intelligence (AI)-based computer-aided detection/diagnosis (CADe/x) has helped improve radiologists’ performance and provides results equivalent or superior to those of radiologists’ alone. This prospective multicenter cohort study aims to generate real-world evidence on the overall benefits and disadvantages of using AI-based CADe/x for breast cancer detection in a population-based breast cancer screening program comprising Korean women aged ≥ 40 years. The purpose of this report is to compare the diagnostic accuracy of radiologists with and without the use of AI-based CADe/x in mammography readings for breast cancer screening of Korean women with average breast cancer risk. @*Methods@#Approximately 32,714 participants will be enrolled between February 2021 and December 2022 at 5 study sites in Korea. A radiologist specializing in breast imaging will interpret the mammography readings with or without the use of AI-based CADe/x. If recall is required, further diagnostic workup will be conducted to confirm the cancer detected on screening. The findings will be recorded for all participants regardless of their screening status to identify study participants with breast cancer diagnosis within both 1 year and 2 years of screening. The national cancer registry database will be reviewed in 2026 and 2027, and the results of this study are expected to be published in 2027. In addition, the diagnostic accuracy of general radiologists and radiologists specializing in breast imaging from another hospital with or without the use of AI-based CADe/x will be compared considering mammography readings for breast cancer screening.DiscussionThe Artificial Intelligence for Breast Cancer Screening in Mammography (AI-STREAM) study is a prospective multicenter study that aims to compare the diagnostic accuracy of radiologists with and without the use of AI-based CADe/x in mammography readings for breast cancer screening of women with average breast cancer risk. AI-STREAM is currently in the patient enrollment phase.Trial RegistrationClinicalTrials.gov Identifier: NCT05024591
RESUMEN
Objective@#We aimed to evaluate the ostium of right coronary artery of anomalous origin from the left coronary sinus (AORL) with an interarterial course throughout the cardiac cycle on CT and analyze the clinical significance of the ostial findings. @*Materials and Methods@#From January 2011 to December 2015, 68 patients (41 male, 57.3 ± 12.1 years) with AORL with an interarterial course and retrospective cardiac CT data were included. AORL was classified as high or low ostial location based on the pulmonary annulus in the diastolic and systolic phases on cardiac CT. In addition, the height, width, height/width ratio, area, and angle of the ostium were measured in both cardiac phases. After cardiac CT, patients were followed until December 31, 2020 for major adverse cardiac events (MACE). Clinical and CT characteristics associated with MACE were explored using Cox regression analysis. @*Results@#During a median follow-up period of 2071 days (interquartile range, 1180.5–2747.3 days), 13 patients experienced MACE (19.1%, 13/68). Seven (10.3%, 7/68) had the ostial location change from high in the diastolic phase to low in the systolic phase. In the univariable analysis, younger age (hazard ratio [HR] = 0.918, p < 0.001), high ostial location (HR = 4.008, p = 0.036), larger height/width ratio (HR = 5.621, p = 0.049), and smaller ostial angle (HR = 0.846, p = 0.048) in the systolic phase were significant predictors of MACE. In multivariable cox regression analysis, younger age (adjusted HR = 0.917, p = 0.002) and high ostial location in the systolic phase (adjusted HR = 4.345, p = 0.026) were independent predictors of MACE. @*Conclusion@#The ostial location of AORL with an interarterial course can change during the cardiac cycle, and high ostial location in the systolic phase was an independent predictor of MACE.
RESUMEN
Purpose@#To identify initial abdominal computed tomography (CT) and laboratory findings prior to a diagnosis of Crohn’s disease (CD) in children. @*Materials and Methods@#In this retrospective study, patients (≤18 year-old) who were diagnosed with CD from 2004 to 2019 and had abdominal CT just prior to being diagnosed with CD were included in the CD group. Patients (≤18 years old) who were diagnosed with infectious enterocolitis from 2018 to 2019 and had undergone CT prior to being diagnosed with enterocolitis were included as a control group. We assessed the diagnostic performances of initial CT and laboratory findings for the diagnosis of CD using logistic regression and the area under the curve (AUC). @*Results@#In total, 107 patients (50 CD patients, 57 control patients) were included, without an age difference between groups (median 13 years old vs. 11 years old, p=0.119). On univariate logistic regression analysis, multisegmental bowel involvement, mesenteric vessel engorgement, higher portal vein/aorta diameter ratio, longer liver longitudinal diameter, lower hemoglobin (≤12.5 g/ dL), lower albumin (≤4 g/dL), and higher platelet (>320×103 /μL) levels were significant factors for CD. On multivariate analysis, multisegmental bowel involvement [odds ratio (OR) 111.6, 95% confidence interval (CI) 4.778–2605.925] and lower albumin levels (OR 0.9, 95% CI 0.891–0.993) were significant factors. When these two features were combined, the AUC value was 0.985 with a sensitivity of 96% and specificity of 100% for differentiating CD. @*Conclusion@#Multisegmental bowel involvement on CT and decreased albumin levels can help differentiate CD from infectious enterocolitis in children prior to a definite diagnosis of CD.
RESUMEN
Purpose@#This study evaluated how artificial intelligence-based computer-assisted diagnosis (AICAD) for breast ultrasonography (US) influences diagnostic performance and agreement between radiologists with varying experience levels in different workflows. @*Methods@#Images of 492 breast lesions (200 malignant and 292 benign masses) in 472 women taken from April 2017 to June 2018 were included. Six radiologists (three inexperienced [<1 year of experience] and three experienced [10-15 years of experience]) individually reviewed US images with and without the aid of AI-CAD, first sequentially and then simultaneously. Diagnostic performance and interobserver agreement were calculated and compared between radiologists and AI-CAD. @*Results@#After implementing AI-CAD, the specificity, positive predictive value (PPV), and accuracy significantly improved, regardless of experience and workflow (all P<0.001, respectively). The overall area under the receiver operating characteristic curve significantly increased in simultaneous reading, but only for inexperienced radiologists. The agreement for Breast Imaging Reporting and Database System (BI-RADS) descriptors generally increased when AI-CAD was used (κ=0.29-0.63 to 0.35-0.73). Inexperienced radiologists tended to concede to AI-CAD results more easily than experienced radiologists, especially in simultaneous reading (P<0.001). The conversion rates for final assessment changes from BI-RADS 2 or 3 to BI-RADS higher than 4a or vice versa were also significantly higher in simultaneous reading than sequential reading (overall, 15.8% and 6.2%, respectively; P<0.001) for both inexperienced and experienced radiologists. @*Conclusion@#Using AI-CAD to interpret breast US improved the specificity, PPV, and accuracy of radiologists regardless of experience level. AI-CAD may work better in simultaneous reading to improve diagnostic performance and agreement between radiologists, especially for inexperienced radiologists.
RESUMEN
Purpose@#This study aimed to investigate whether a deep learning model for automated detection of unruptured intracranial aneurysms on time-of-flight (TOF) magnetic resonance angiography (MRA) can achieve a target diagnostic performance comparable to that of human radiologists for approval from the Korean Ministry of Food and Drug Safety as an artificial intelligence-applied software. @*Materials and Methods@#In this single-center, retrospective, confirmatory clinical trial, the diagnostic performance of the model was evaluated in a predetermined test set. After sample size estimation, the test set consisted of 135 aneurysm-containing examinations with 168 intracranial aneurysms and 197 aneurysm-free examinations. The target sensitivity and specificity were set as 87% and 92%, respectively. The patient-wise sensitivity and specificity of the model were analyzed. Moreover, the lesion-wise sensitivity and false-positive detection rate per case were also investigated. @*Results@#The sensitivity and specificity of the model were 91.11% [95% confidence interval (CI): 84.99, 95.32] and 93.91% (95% CI:89.60, 96.81), respectively, which met the target performance values. The lesion-wise sensitivity was 92.26%. The overall falsepositive detection rate per case was 0.123. Of the 168 aneurysms, 13 aneurysms from 12 examinations were missed by the model. @*Conclusion@#The present deep learning model for automated detection of unruptured intracranial aneurysms on TOF MRA achieved the target diagnostic performance comparable to that of human radiologists. With high standalone performance, this model may be useful for accurate and efficient diagnosis of intracranial aneurysm.
RESUMEN
Purpose@#This study aimed to investigate the optimal threshold value in Hounsfield units (HU) on CT to detect the solid components of pulmonary subsolid nodules using pathologic invasive foci as reference. @*Materials and Methods@#Thin-section non-enhanced chest CT scans of 25 patients with pathologically confirmed minimally invasive adenocarcinoma were retrospectively reviewed. On CT images, the solid portion was defined as the area with higher attenuation than various HU thresholds ranging from -600 to -100 HU in 50-HU intervals. The solid portion was measured as the largest diameter on axial images and as the maximum diameter on multiplanar reconstruction images. A linear mixed model was used to evaluate bias in each threshold by using the pathological size of invasive foci as reference. @*Results@#At a threshold of -400 HU, the biases were lowest between the largest/maximum diameter of the solid portion of subsolid nodule and the size of invasive foci of the pathological specimen, with 0.388 and -0.0176, respectively. They showed insignificant difference (p = 0.2682, p = 0.963, respectively) at a threshold of -400 HU. @*Conclusion@#For quantitative analysis, -400 HU may be the optimal threshold to define the solid portion of subsolid nodules as a surrogate marker of invasive foci.
RESUMEN
Objective@#The purpose of this meta-analysis was to investigate the pooled agreements of the coronary artery calcium (CAC) severities assessed by electrocardiogram (ECG)-gated and non-ECG-gated CT and evaluate the impact of the scan parameters. @*Materials and Methods@#PubMed, EMBASE, and the Cochrane library were systematically searched. A modified Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to evaluate the quality of the studies. Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and the correlation coefficient of the CAC scores or the weighted kappa for the categorization of the CAC severities detected by the two modalities. The heterogeneity among the studies was also assessed. Subgroup analyses were performed based on factors that could affect the measurement of the CAC score and severity: slice thickness, reconstruction kernel, and radiation dose for non-ECG-gated CT. @*Results@#A total of 4000 patients from 16 studies were included. The pooled bias was 62.60, 95% LOA were -36.19 to 161.40, and the pooled correlation coefficient was 0.94 (95% confidence interval [CI] = 0.89–0.97) for the CAC score. The pooled weighted kappa of the CAC severity was 0.85 (95% CI = 0.79–0.91). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, the agreement between the CAC categorizations was better when the two CT examinations had reconstructions based on the same slice thickness and kernel. @*Conclusion@#The pooled agreement of the CAC severities assessed by the ECG-gated and non-ECG-gated CT was excellent; however, it was significantly affected by scan parameters, such as slice thickness and the reconstruction kernel.
RESUMEN
Objective@#To compare the performance of the deep learning-based lesion detection algorithm (DLLD) in detecting liver metastasis with that of radiologists. @*Materials and Methods@#This clinical retrospective study used 4386-slice computed tomography (CT) images and labels from a training cohort (502 patients with colorectal cancer [CRC] from November 2005 to December 2010) to train the DLLD for detecting liver metastasis, and used CT images of a validation cohort (40 patients with 99 liver metastatic lesions and 45 patients without liver metastasis from January 2011 to December 2011) for comparing the performance of the DLLD with that of readers (three abdominal radiologists and three radiology residents). For per-lesion binary classification, the sensitivity and false positives per patient were measured. @*Results@#A total of 85 patients with CRC were included in the validation cohort. In the comparison based on per-lesion binary classification, the sensitivity of DLLD (81.82%, [81/99]) was comparable to that of abdominal radiologists (80.81%, p = 0.80) and radiology residents (79.46%, p = 0.57). However, the false positives per patient with DLLD (1.330) was higher than that of abdominal radiologists (0.357, p < 0.001) and radiology residents (0.667, p < 0.001). @*Conclusion@#DLLD showed a sensitivity comparable to that of radiologists when detecting liver metastasis in patients initially diagnosed with CRC. However, the false positives of DLLD were higher than those of radiologists. Therefore, DLLD could serve as an assistant tool for detecting liver metastasis instead of a standalone diagnostic tool.
RESUMEN
Objective@#This study aimed to investigate the regional amyloid burden and myocardial deformation using T1 mapping and strain values in patients with cardiac amyloidosis (CA) according to late gadolinium enhancement (LGE) patterns. @*Materials and Methods@#Forty patients with CA were divided into 2 groups per LGE pattern, and 15 healthy subjects were enrolled. Global and regional native T1 and T2 mapping, extracellular volume (ECV), and cardiac magnetic resonance (CMR)-feature tracking strain values were compared in an intergroup and interregional manner. @*Results@#Of the patients with CA, 32 had diffuse global LGE (group 2), and 8 had focal patchy or no LGE (group 1). Global native T1, T2, and ECV were significantly higher in groups 1 and 2 than in the control group (native T1: 1384.4 ms vs. 1466.8 ms vs. 1230.5 ms; T2: 53.8 ms vs. 54.2 ms vs. 48.9 ms; and ECV: 36.9% vs. 51.4% vs. 26.0%, respectively; all, p < 0.001). Basal ECV (53.7%) was significantly higher than the mid and apical ECVs (50.1% and 50.0%, respectively; p < 0.001) in group 2. Basal and mid peak radial strains (PRSs) and peak circumferential strains (PCSs) were significantly lower than the apical PRS and PCS, respectively (PRS, 15.6% vs. 16.7% vs. 26.9%; and PCS, -9.7% vs. -10.9% vs. -15.0%; all, p < 0.001). Basal ECV and basal strain (2-dimensional PRS) in group 2 showed a significant negative correlation (r = -0.623, p < 0.001). Group 1 showed no regional ECV differences (basal, 37.0%; mid, 35.9%; and apical, 38.3%; p = 0.184). @*Conclusion@#Quantitative T1 mapping parameters such as native T1 and ECV may help diagnose early CA. ECV, in particular, can reflect regional differences in the amyloid deposition in patients with advanced CA, and increased basal ECV is related to decreased basal strain. Therefore, quantitative CMR parameters may help diagnose CA and determine its severity in patients with or without LGE.
RESUMEN
Purpose@#This study aimed to investigate whether a deep learning model for automated detection of unruptured intracranial aneurysms on time-of-flight (TOF) magnetic resonance angiography (MRA) can achieve a target diagnostic performance comparable to that of human radiologists for approval from the Korean Ministry of Food and Drug Safety as an artificial intelligence-applied software. @*Materials and Methods@#In this single-center, retrospective, confirmatory clinical trial, the diagnostic performance of the model was evaluated in a predetermined test set. After sample size estimation, the test set consisted of 135 aneurysm-containing examinations with 168 intracranial aneurysms and 197 aneurysm-free examinations. The target sensitivity and specificity were set as 87% and 92%, respectively. The patient-wise sensitivity and specificity of the model were analyzed. Moreover, the lesion-wise sensitivity and false-positive detection rate per case were also investigated. @*Results@#The sensitivity and specificity of the model were 91.11% [95% confidence interval (CI): 84.99, 95.32] and 93.91% (95% CI:89.60, 96.81), respectively, which met the target performance values. The lesion-wise sensitivity was 92.26%. The overall falsepositive detection rate per case was 0.123. Of the 168 aneurysms, 13 aneurysms from 12 examinations were missed by the model. @*Conclusion@#The present deep learning model for automated detection of unruptured intracranial aneurysms on TOF MRA achieved the target diagnostic performance comparable to that of human radiologists. With high standalone performance, this model may be useful for accurate and efficient diagnosis of intracranial aneurysm.
RESUMEN
Purpose@#This study aimed to investigate the optimal threshold value in Hounsfield units (HU) on CT to detect the solid components of pulmonary subsolid nodules using pathologic invasive foci as reference. @*Materials and Methods@#Thin-section non-enhanced chest CT scans of 25 patients with pathologically confirmed minimally invasive adenocarcinoma were retrospectively reviewed. On CT images, the solid portion was defined as the area with higher attenuation than various HU thresholds ranging from -600 to -100 HU in 50-HU intervals. The solid portion was measured as the largest diameter on axial images and as the maximum diameter on multiplanar reconstruction images. A linear mixed model was used to evaluate bias in each threshold by using the pathological size of invasive foci as reference. @*Results@#At a threshold of -400 HU, the biases were lowest between the largest/maximum diameter of the solid portion of subsolid nodule and the size of invasive foci of the pathological specimen, with 0.388 and -0.0176, respectively. They showed insignificant difference (p = 0.2682, p = 0.963, respectively) at a threshold of -400 HU. @*Conclusion@#For quantitative analysis, -400 HU may be the optimal threshold to define the solid portion of subsolid nodules as a surrogate marker of invasive foci.
RESUMEN
Purpose@#This study aimed to evaluate the utility of the 16-cm axial volume scan technique for calculating the coronary artery calcium score (CACS) using non-enhanced chest CT. @*Materials and Methods@#This study prospectively enrolled 20 participants who underwent both, non-enhanced chest CT (16-cm-coverage axial volume scan technique) and calciumscore CT, with the same parameters, differing only in slice thickness (in non-enhanced chest CT = 0.625, 1.25, 2.5 mm; in calcium score CT = 2.5 mm). The CACS was calculated using the conventional Agatston method. The difference between the CACS obtained from the two CT scans was compared, and the degree of agreement for the clinical significance of the CACS was confirmed through sectional analysis. Each calcified lesion was classified by location and size, and a one-to-one comparison of non-contrast-enhanced chest CT and calcium score CT was performed. @*Results@#The correlation coefficients of the CACS obtained from the two CT scans for slice thickness of 2.5, 1.25, and 0.625 mm were 0.9850, 0.9688, and 0.9834, respectively. The mean differences between the CACS were -21.4% at 0.625 mm, -39.4% at 1.25 mm, and -76.2% at 2.5 mm slice thicknesses. Sectional analysis revealed that 16 (80%), 16 (80%), and 13 (65%) patients showed agreement for the degree of coronary artery disease at each slice interval, respectively. Inter-reader agreement was high for each slice interval. The 0.625 mm CT showed the highest sensitivity for detecting calcified lesions. @*Conclusion@#The values in the non-contrast-enhanced chest CT, using the 16-cm axial volume scan technique, were similar to those obtained using the CACS in the calcium score CT, at 0.625 mm slice thickness without electrocardiogram gating. This can ultimately help predict cardiovascular risk without additional radiation exposure.
RESUMEN
Objective@#To assess the feasibility of quantitatively assessing pancreatic steatosis using magnetic resonance imaging (MRI) and its correlation with obesity and metabolic risk factors in pediatric patients. @*Materials and Methods@#Pediatric patients (≤ 18 years) who underwent liver fat quantification MRI between January 2016 and June 2019 were retrospectively included and divided into the obesity and control groups. Pancreatic proton density fat fraction (P-PDFF) was measured as the average value for three circular regions of interest (ROIs) drawn in the pancreatic head, body, and tail. Age, weight, laboratory results, and mean liver MRI values including liver PDFF (L-PDFF), stiffness on MR elastography, and T2* values were assessed for their correlation with P-PDFF using linear regression analysis. The associations between P-PDFF and metabolic risk factors, including obesity, hypertension, diabetes mellitus (DM), and dyslipidemia, were assessed using logistic regression analysis. @*Results@#A total of 172 patients (male:female = 125:47; mean ± standard deviation [SD], 13.2 ± 3.1 years) were included. The mean P-PDFF was significantly higher in the obesity group than in the control group (mean ± SD, 4.2 ± 2.5% vs. 3.4 ± 2.4%; p = 0.037). L-PDFF and liver stiffness values showed no significant correlation with P-PDFF (p = 0.235 and p = 0.567, respectively). P-PDFF was significantly associated with obesity (odds ratio 1.146, 95% confidence interval 1.006–1.307, p = 0.041), but there was no significant association with hypertension, DM, and dyslipidemia. @*Conclusion@#MRI can be used to quantitatively measure pancreatic steatosis in children. P-PDFF is significantly associated with obesity in pediatric patients.