RESUMEN
ABSTRACT The aim of this study was to determine Vickers microhardness (HV) in bulk fill resins at different depths. Test specimens were prepared with different bulk fill resins: Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] and Surefill (Dentsply) [SF]. Semi-cylindrical test specimens were prepared in a mold 6 mm in diameter and 4 mm thick (n=5). A 1000 mW/cm2 light curing unit was applied (Coltolux LED - Coltene) for 20 seconds. HV was determined with three indentations (Vickers Future Tech FM300, 300 g, 8 s) at four depths: 1, 2, 3 and 4 mm from the top surface to the interior. Data were recorded immediately (t0) and 24 hours later (t24). Results were analyzed with two-way ANOVA (p<0.05), and multiple comparisons were performed using Tukey's test. Mean and SD of HV at t0 for each mm were: [FBF] t0: 49.23(4.65) / 48.32(3.36) / 44.38(2.06) / 40.59(2.58); [FBF] t24: 61.37(3.47) / 62.63(3.03) / 57.27(5.22) / 56.37(5.88); [SDR] t0: 27.81(3.13) / 28.07(2.4) / 27.24(2.94) / 25.71(3.0); [SDR] t24: 35.11(2.16) / 35.17(1.96) / 35.53(1.81) / 33.18(2.08); [FU] t0: 41.43(1.41) / 39.87(0.88) / 38.11(1.81) / 39.09(1.92); [FU] t24: 49.27(1.54) / 48.77(1.77) / 48.65(1.88) / 46.76(4.93); [SF] t0: 71.35(7.09) / 67.39(9.76) / 68.95(6.21) / 64.1(8.35); [SF] t24: 76.06(6.61) / 75.31(9.37) / 75.2(11.57) / 69.81(12.14). ANOVA showed significant effect of material, depth and recording time (p<0.05), and Tukey's test showed that recording sites (depths) differed significantly, giving four homogeneous groups. Under the conditions of this study, it can be concluded that microhardness of bulk-fill resins can be affected by depth and post-curing time.
RESUMEN El objetivo del presente estudio fue determinar la microdureza Vickers (HV) en resinas bulk-fill a diferentes profundidades. Se confeccionaron probetas semicilíndricas de 6 mm de diámetro y 4 mm de profundidad con diferentes composites de aplicación en bloque (Bulk-fill): Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] y Surefill (Dentsply) [SF]. Se polimerizaron con Coltolux LED (Coltene) con 1000 mW/cm2 durante 20s. La HV se determinó realizando 3 indentaciones con 300 g durante 8 s a 1,2 3 y 4 mm desde la superficie de la probeta hacia el interior inmediatamente después de curada y a las 24 h. Se utilizó un microdurómetro Vickers Future Tech FM300. Los resultados se analizaron estadísticamente mediante ANOVA de dos vías y Prueba de Tukey. La media y DS de HV fueron: [FBF] t0: 49,23(4,65) / 48,32(3,36) / 44,38(2,06) / 40,59(2,58); [FBF] t24: 61,37(3,47) / 62,63(3,03) / 57,27(5,22) / 56,37(5,88); [SDR] t0: 27,81(3,13) / 28,07(2,4) / 27,24(2,94) / 25,71(3,0); [SDR] t24: 35,11(2,16) / 35,17(1,96) / 35,53(1,81) / 33,18(2,08); [FU] t0: 41,43(1,41) / 39,87(0,88) / 38,11(1,81) / 39,09(1,92); [FU] t24: 49,27(1,54) / 48,77(1,77) / 48,65(1,88) / 46,76(4,93); [SF] t0: 71,35(7,09) / 67,39(9,76) / 68,95(6,21) / 64,1(8,35); [SF] t24: 76,06(6,61) / 75,31(9,37) / 75,2(11,57) / 69,81(12,14). La evaluación con análisis de varianza mostró el efecto significativo de las variables material, profundidad y momento del registro (p<0,05) y la prueba de Tukey mostró que los sitios de registro (profundidad) fueron estadísticamente significativos, dando cuatro grupos homogéneos. Bajo las condiciones de este estudio podemos concluir que la microdureza de las resinas de inserción en bloque se ve afectada por el nivel de profundidad y el tiempo pos curado.
RESUMEN
ABSTRACT The aim of this study was to compare the capacity of two reciprocating NiTi instruments in removing gutta-percha/sealer material from simulated curved root canals (SCRC). The time required for filling material removal was also recorded. Twenty SCRCs were divided into two groups of 10 (n=10) samples each. In Group 1, the SCRC were prepared to a R25 Reciproc Blue instrument (RCPB; VDW, Munich, Germany). In Group 2 the SCRC were prepared to a Primary WaveOne Gold instrument (PWOG; Dentsply, Ballaigues, Switzerland). In both groups, the canals were filled with matched-taper single gutta-percha cones and AH Plus sealer. Filling materials were removed with R25 RCPB (Group 1) and PWOG (Group 2). The amount of remaining gutta-percha/sealer was calculated at three predetermined levels of evaluation located at 2, 6 and 10 mm from the WL and expressed in percentages. Canals re-treated with RCPB contained significantly less remaining gutta-percha/sealer compared to canals prepared with PWOG (P=0.02). The RCPB instruments required significantly less time to complete the retreatment procedures (P<0.01). No unwinding or instrument separation was noted. RCPB instruments removed significantly more gutta-percha/sealer from simulated curved root canals than PWOG. However, neither of the tested instruments completely removed all filling materials.
RESUMEN El propósito del presente estudio fue comparar la capacidad de dos instrumentos de NiTi de movimiento reciproco para remover la obturación de gutapercha/sellador durante el retratamiento de conductos curvos simulados (SCRC). El tiempo requerido para la remoción del material fue también registrado. Se utilizaron veinte (n=20) SCRC divididos en dos grupos de diez especimenes (n=10) cada uno. En el Grupo 1 los SCRC se prepararon hasta un instrumento Reciproc Blue R25 (RCPB; VDW, Munich, Germany). En el Grupo 2, los SCRC se prepararon hasta un instrumento WaveOne Gold Primary (PWOG; Dentsply, Ballaigues, Switzerland). En ambos grupos los conductos se obturaron con cono único de gutapercha de conicidad creciente y el sellador AH Plus. La remoción de los materiales de obturación se realizó mediante los instrumentos RCPB R25 (Grupo 1) o PWOG (Grupo 2). La cantidad de gutapercha/sellador remanente se calculó en tres niveles de evaluación predeterminados ubicados a 2, 6 y 10 mm de la LT, y finalmente fue expresada en porcentajes. La cantidad de gutapercha/ sellador remanente en los SCRC retratados con RCPB fue significativamente menor en comparación con los que fueron retratados con PWOG (P=0.02). Los instrumentos RCPB requirieron un tiempo significativamente menor para completar el retratamiento (P<0.01). No se observaron deformaciones o separación de los instrumentos. Los instrumentos RCPB removieron una cantidad significativamente mayor de gutapercha/sellador que los instrumentos PWOG en conductos curvos simulados. Sin embargo, ninguno de los instrumentos ensayados removió completamente los materiales de obturación.
RESUMEN
ABSTRACT The aim of this study was to determine color change after accelerated artificial ageing (AAA) of different composite cements that are used with veneers. Five cylindrical test specimens, 15 mm in diameter and 2 mm thick, were made from a single layer of each of the following: RelyX Veneer 3M ESPE (RX), Paracore White Coltene (PC), Solocem White Opaque Coltene (SO), Resin Duo Cement Densell (DC), Panavia V5 Paste Kuraray Noritake (PA) and Panavia F2.0 Kuraray Noritake (PF) (30 specimens altogether). The specimens were light cured following manufacturers' instructions using a Coltolux LED (Coltene) unit. Initial color was determined using an Easyshade - Vita Zahnfabrik Spectrophotometer. Then, the specimens were subjected to AAA for two weeks (336 hours) with cycles of 4 hours of UV light at 60 °C and 4 hours of vapor condensation at 50 °C, successively, after which color was recorded again. Color change was determined for each specimen according to the difference in shade on the Vita scale before and after AAA. Results were analyzed using Kruskal Wallis test. Mean and standard deviation for each group were: RX 8.40 (1.52); PC 8.60 (3.13); SO 6.40 (3.51); DC 10.00 (0.00); PA 7.60 (3.29); PF 2.00 (0.00). The Kruskal Wallis test showed significant difference for material (p<0.05), and comparison of means showed difference between Panavia F2.0 and the other materials. A table providing equivalence between the Vita Classic and CIELAB scales was used to transfer the recorded colors to the CIELAB scale, and the color difference ΔE was calculated for each group, where ΔL, Δa and Δb are the differences in the L, a and b values before and after the AAA. The mean and standard deviation were analyzed statistically by the ANOVA test and Tukey's test. Mean and standard deviation for each group were: RX 14.94 (2.02); PC 14.51 (4.02); SO 12.08 (4.53); DC 16.31 (0.00); PA 10.9 (3.38); PF 7.24 (0.00). The ANOVA test showed significant difference for material (p<0.05). Tukey's test showed two groups (PF-DC, RX, PA). Under the experimental conditions of this study, it can be concluded that accelerated ageing significantly affects the color stability of the resin based cements tested.
RESUMEN El objetivo de este trabajo fue determinar el cambio de coloración de distintos medios de fijación a base de resinas con indicación para carillas estéticas luego de someterse al envejecimiento artificial acelerado (AAA). Se confeccionaron 30 probetas cilíndricas de 15 mm de diámetro y 2 mm de espesor con RelyX Veneer 3M ESPE (RX), Paracore White Coltene (PC), Solocem White Opaque Coltene (SO), Resin Duo Cement Densell (DC), Panavia V5 Paste Kuraray Noritake (PA) y Panavia F2.0 Kuraray Noritake (PF) de una sola capa de material. Se polimerizaron según las indicaciones del fabricante con unidad de curado Coltolux LED (Coltene). Cada grupo quedó conformado con 5 probetas de cada material. Se tomó el color con el espectrofotómetro Easyshade de Vita Zahnfabrik. A continuación, se sometieron a AAA por dos semanas (336 horas) con ciclos de 4 horas de radiaciones ultravioletas a 60°C Y 4 horas de condensación de vapor de agua a 50°C sucesivamente. Una vez terminado este proceso se volvió a registrar el color. El cambio de color se evaluó dentro de la escala de color, ordenada en función del valor. El dato registrado fue la diferencia en la posición inicial y final en esta escala. Los resultados obtenidos para cada grupo fueron analizados por medio de la prueba de Kruskal Wallis. Los valores de media y desvío estándar de cada grupo fueron: RX 8,40 (1,52); PC 8,60 (3,13); SO 6,40 (3,51); DC 10,00 (0,00); PA 7,60 (3,29); PF 2,00 (0,00). El análisis con la prueba de Kruskal Wallis mostró diferencia significativa para el factor material (p<0.05) y la comparación de medias mostró diferencia entre PF y el resto de los materiales. Por otra parte, con una tabla de equivalencia entre los colores en escala de Vita Classic y CIE Lab, se hicieron el pasaje de los valores registrados a la escala de CIE Lab y se calculó la diferencia de color ΔE de cada grupo antes y después del AAA. La media y el desvío estándar fueron analizados estadísticamente por el test de ANOVA y prueba de Tukey. Los valores de media y desvío estándar de cada grupo fueron: RX 14,94 (2,02); PC 14,51 (4,02); SO 12,08 (4,53); DC 16,31 (0,00); PA 10,9 (3,38); PF 7,24 (0,00). En la evaluación de los resultados con ANOVA se encontró diferencia significativa entre los materiales evaluados (p<0,05). La comparación de medias con prueba de Tukey mostró la presencia de dos grupos (PF-DC, RX, PA). En las condiciones experimentales de este trabajo puede concluirse que el envejecimiento acelerado afecta significativamente la estabilidad de color de los cementos utilizados en este trabajo.
RESUMEN
esumen Objetivo: Comparar la microdureza de dos materiales endodónticos a base de silicato de calcio: MTA Densell Endo Sealer y TotalFill BC Sealer. Materiales y métodos: Se evaluó la microdureza de los selladores MTA Densell Endo Sealer (Grupo 1, n=5) y To- talFill BC Sealer (Grupo 2, n=5) contenidos en cilindros de dentina de vacuno a los 14 días posteriores a su fraguado. La medición se realizó a temperatura ambiente mediante la prue- ba de indentación Vickers. Se realizaron cinco indentaciones por probeta con una carga de 100 g durante 10 s cada una. Las mediciones se convirtieron a valores de dureza Vickers (HV) y los promedios de los valores HV de cada grupo se compararon por medio de la prueba t de Student con un nivel de significación de P <0,05. Resultados: A los 14 días, luego del fraguado, la mi- crodureza de MTA Densell Endo Sealer fue significativamen- te mayor (P=0,001) que la de TotalFill BC Sealer. Conclusiones: Los resultados sugieren que a causa de su dureza la remoción de MTA Densell Endo Sealer puede resultar dificultosa cuando está indicado un retratamiento (AU)
Aim: To compare the microhardness of two silicate-based endodontic materials: MTA Densell Endo Sealer and Total Fill BC Sealer. Materials and methods: Samples of MTA Densell Endo Sealer (Group 1, n=5) and Total Fill BC Sealer (Group 2, n=5) contained into cow dentine cylinders were subjected to the Vickers Microhardness Indentation test at room temper- ature and 14 days after setting. Five indentations per sample were performed under a load of 100 g for 10 s. The indenta- tion measurements were converted into hardness values (HV). Mean HV values of each group were compared using the Stu- dent t test at a significance level of P <0,05. Results: 14 days after setting, the microhardness of MTA Densell Endo Sealer was significantly greater (P=0,001) than that of Total Fill BC Sealer. Conclusions: The results of this study suggest that due to its hardness the removal of MTA Densell Endo Sealer could be difficult to perform when a root canal retreatment is indicated (AU)
Asunto(s)
Materiales de Obturación del Conducto Radicular , Cemento de Silicato , Pruebas de Dureza , Ensayo de MaterialesRESUMEN
ABSTRACT The aim of this descriptive ex vivo study was to evaluate qualitatively the depth of pit and fissures (P&F) of the enamel in human mandibular third molars. Fifty (n=50) extracted human mandibular third molars were cleaned and disinfected. All tooth surfaces were coated with nail varnish except for a 1-mm margin around the periphery of the occlusal surface. The teeth were immersed for 48 hours at 37 °C in 1% methylene blue dye solution prepared in artificial saliva. After cleaning, the crowns were separated from the root at the cementoenamel junction and subsequently sectioned longitudinally in buccolingual direction at the location of the central fossa. All sections were examined using a stereoscopic microscope and photographed. The images were downloaded on a computer. The length of penetration of the P&F was recorded using the following scoring system: C1: P&F extended to half of the enamel thickness; C2: P&F extended beyond half of the enamel thickness without reaching the dentine-enamel junction; C3: P&F extended to the dentine-enamel junction. For pits, C1, C2 and C3 were observed in 35, 9 and 6 teeth, respectively, while for fissures, C1, C2 and C3 were observed in 15, 18 and 17 teeth, respectively. The P&F detected in the samples extended to the deepest portions of enamel, quite frequently reaching the enamel-dentine junction. Clinicians should recognize that even if pits and fissures are not clinically obvious, they penetrate deep into the enamel and frequently reach the dentine-enamel junction. Effective treatment is recommended to block access to P&F, thus preventing ingress of bacteria.
RESUMEN Objetivos: El objetivo del presente estudio descriptivo fue evaluar cualitativamente mediante un ensayo ex vivo la profundidad de las fosas y fisuras (F&F) del esmalte en terceros molares inferiores humanos. Materiales y métodos: Cincuenta (n=50) terceros molares inferiores sanos extraídos se lavaron, se descontaminaron y se recubrieron con esmalte para uñas hasta 1 mm menos del área de las F&F. Luego se sumergieron durante 48 horas a 37°C en una solución de azul de metileno al 1% (pH 7,4) preparada con saliva artificial. Posteriormente se lavaron y se separaron las coronas a nivel del límite amelocementario. En cada molar se realizó una sección longitudinal de 1 mm de espesor con orientación vestíbulo-lingual a nivel de la fosa central. Las secciones fueron analizadas con microscopio estereoscópico y fotografiadas. Las imágenes se transfirieron a una computadora. Se determinó cualitativamente la extensión de las F&F en el espesor del esmalte y se las clasificó de acuerdo a 3 categorías. C1: extensión hasta la mitad del espesor del esmalte; C2: extensión que supera la mitad del espesor del esmalte sin afectar el límite amelodentinario; C3: extensión que llega al límite amelodentinario. Resultados: Para las fosas, 35, 9 y 6 especimenes correspondieron a las categorías C1, C2 y C3 respectivamente. Para las fisuras, 15, 18 y 17 especimenes correspondieron a las categorías C1, C2 y C3 respectivamente. Conclusiones: Las fosas y fisuras de la muestra analizada se extienden hasta la zona más profunda del espesor del esmalte. Con cierta frecuencia llegan hasta el límite amelodentinario.
RESUMEN
ABSTRACT The aim of this study was to evaluate the ability of different irrigation protocols to remove from the walls of the root canal and entrance to dentinal tubules the smear layer produced during preparation for a fiber post. Fifty decoronated human lower premolars were treated endodontically and the apical third of the canal was filled with a single gutta-percha point using warm vertical compaction. Ten millimeters were left free for post preparation, which was done by sequential use of a Largo #1 drill and Exacto #3 pilot drill (Angelus, Brazil), with irrigation with distilled water upon each instrument change. Samples were distributed randomly into 5 groups (n=10). G 1: No irrigation after post preparation. G 2: Distilled water activated for 60 s + distilled water. G 3: 5.25% NaOCl 15 s+ distilled water. G 4: 17% EDTA (Farmadental, Argentina) 60 s + 5.25% NaOCl 15 s + distilled water. G 5: 10% polyacrylic acid (Densell) 15 s + distilled water. Irrigant was activated mechanically with a low-speed conical brush. Roots were then split longitudinally in vestibular-lingual direction. Each surface was observed under SEM in its different thirds. Microphotographs were taken at 150X and 600X magnification and results analyzed statistically using Kruskall Wallis and Friedman tests (p<0.05). The results [mean (standard deviation)] were: for 150X: G1 11.00 (1.33), G2 7.50 (3.13), G3 6.30 (2.58), G4 2.20 (2.80), G5 4.30 (1.50), and for 600X G1 11.40 (0.84), G2 10.00 (1.94), G3 7.70 (3.33), G4 5.80 (3.70), G5 7.20 (2.65). The statistical analysis showed significant differences between irrigants (p<0.05) but not between root thirds (p>>0.05). The EDTA+NaOCl combination and polyacrylic acid showed greater capacity to remove the smear layer created during post preparation.
RESUMEN El objetivo del presente trabajo fue evaluar la capacidad de diferentes protocolos de irrigación para remover el barro dentinario de las paredes del conducto y entrada de los túbulos dentinarios, producido durante la preparación para anclaje intarradicular. Se utilizaron 50 premolares inferiores humanos a los cuales se les cortó la corona clínica. Luego se les realizó tratamiento endodóntico y obturación del tercio apical con cono único de conicidad aumentada y compactación vertical caliente. Se dejaron libres 10 mm para la preparación para poste que se realizó utilizando secuencialmente fresa de Largo # 1y fresa piloto Exacto #1(Angelus, Brasil), irrigando a cada cambio de instrumento con agua destilada. Las muestras fueron distribuidas aleatoriamente en 5 grupos (n=10). G 1: No se efectuó ningún lavaje. Los irrigantes fueron activados con cepillo mecánico cónico a baja velocidad. G 2: Agua destilada activada 60 s+ agua destilada G 3: NaOCl al 5,25%, 15 s+ agua destilada. G 4: EDTA al 17% (Farmadental, Argentina) 60 s +NaOCl al 5,25% 15 s , + agua destilada. G 5 : Ácido poliacrílico al 10% ( Densell) 15 s + agua destilada. Posteriormente, las raíces fueron seccionadas longitudinalmente en sentido vestíbulo lingual. Cada superficie fue observada al MEB en sus diferentes tercios. Las micrografías se realizaron a 150 y 600 X y los resultados analizados estadísticamente mediante test de Kruskall Wallis y Friedman (p<0,05), Los resultados [Medias (desviaciones estándar)] fueron: para 150X G1 11,00(1,33), G2 7,50 (3,13), G3 6,30 (2,58), G4 2,20 (2,80), G5 4,30 (1,50) y para 600X G1 11,40 (0,84), G2 10,00 (1,94), G3 7,70 (3,33), G4 5,80 (3,70), G5 7,20 (2,65). El análisis estadístico mostró diferencia significativa entre irrigantes (p<0,05) pero no entre tercios radiculares (p>0,05). La combinación de EDTA+NaOCl y el ácido poliacrílico tendrían mayor capacidad de remoción del barro dentinario creado durante la preparación para poste.
Asunto(s)
Humanos , Irrigantes del Conducto Radicular/farmacología , Preparación del Conducto Radicular/métodos , Cavidad Pulpar/efectos de los fármacos , Irrigantes del Conducto Radicular/administración & dosificación , Microscopía Electrónica de Rastreo , Capa de Barro Dentinario , Cavidad Pulpar/diagnóstico por imagenRESUMEN
La presente comunicación tiene como objetivo informar sobre la cantidad de material que se pierde junto con las puntas dispensadoras descartables durante el uso de materiales endodónticos contenidos en jeringas y comprobar si esa cantidad es significativa en comparación con el contenido total original (15 g). Se procedió a pesar en una balanza de precisión 12 puntas dispensadoras descartables vacías, pertenecientes a dos materiales de uso endodóntico: 2Seal EasyMix (VDW) y Activa BioActive-Base/Liner (PulpDent Corp.). La sumatoria del peso (masa) en las 12 puntas pertenecientes a cada uno de los materiales ensayados fue considerada como peso total de las puntas vacías. Posteriormente, las puntas se llenaron completamente con los materiales, se almacenaron durante 48 horas para permitir el fraguado y finalmente se las pesó nuevamente. La diferencia entre el peso de las 12 puntas vacías y llenas fue considerada como la cantidad de material remanente que se descarta con ellas. La diferencia entre los totales de masa contenida en las puntas llenas de cada material y el contenido original de las jeringas representó la proporción de material que se descarta sin haber sido utilizado. Cuando el porcentaje de material descartado fue menor o igual al 20%, el resultado se consideró aceptable. Se observó que la proporción de ambos materiales fue mayor al 20% (2Seal EasyMix=44,36%; Activa BioActive-Base/Liner=36,87%). Se concluyó que el empleo de materiales endodónticos contenidos en jeringas dispensadoras produce la pérdida de una importante proporción de material durante los procedimientos operatorios (AU)
In order to inform about the amount of material that is lost along with the disposable dispensing tips during the use of endodontic materials contained in deliver syringes and check if that amount is significant compared to the total original content (15 g) of them. 12 empty disposable dispensing tips belonging to two endodontic materials: 2Seal EasyMix (VDW) and ActivaBioactive Base/liner (PulpDent Corp.), were weighed on a precision scale. The sum of the weight (mass) of each of the 12 tips belonging to each of the materials tested was considered as the total weight of the empty tips. Subsequently, the tips were completely filled with the materials, stored for 48 hours to allow them to set and finally weighed again. The difference between the weight of the 12 empty and full tips was considered as the amount of material remaining within them that is discarded. The difference between the total mass contained in 12 filled tips of each material and the original syringe content represented the proportion of material discarded without being used. It was considered that if the % of discarded material was ≤20% this would be considered acceptable. It was observed that the proportion of both materials was >20% (2Seal EasyMix = 44.36%; ActivaBioactive Base/liner = 36.87%). The use of endodontic materials contained in dispensing syringes causes the loss of a significant proportion of material during the operative procedures (AU)
Asunto(s)
Materiales de Obturación del Conducto Radicular , Jeringas , Interpretación Estadística de Datos , Equipos DesechablesRESUMEN
El objetivo de este estudio fue evaluar la estabilidad dimensional lineal de diferentes hidrocoloides irreversibles enfunción del tiempo. Se confeccionó una matriz metálica con sus correspondientes cubetas individuales realizadas con láminas termoplásticas (Sabilex, de 0.125 mm de espesor). Sele realizaron perforaciones para la retención del material. Se tomaron cinco impresiones con cada material a esta matriz, utilizando Kromopan 100 (LASCOD) [AlKr], que presentauna estabilidad dimensional de 100 horas, y Phase Plus (ZHERMACK) [AlPh], que tiene una estabilidad dimensional de 48 horas. Luego se tomaron fotografías estandarizadas adiferentes intervalos de tiempo (0, 15, 30, 45, 60, 120 minutos; 12, 24 y 96 horas), usando un dispositivo ad-hoc. Las imágenes se analizaron con software de procesamiento de imágenes(UTHSCSA Image Tool) realizando la medición de la distancia entre las intersecciones de surcos previamente realizados en la porción superior de la matriz. Los resultados obtenidos fueronanalizados mediante Análisis de Varianza para mediciones repetidas. Se detallan los datos iniciales y finales obtenidos (media y DS): AlKr: 16,44 (0,22) y 16,34 (0,11), AlPh: 16,40(0,06) y 16,18 (0,06). El análisis estadístico ha mostrado el efecto significativo para las variables material y tiempo. Bajo las condiciones de este estudio podemos concluir que tiempoafectaría significativamente la estabilidad dimensional lineal de los hidrocoloides irreversibles...
Asunto(s)
Humanos , Alginatos/química , Coloides/química , Precisión de la Medición Dimensional , Materiales de Impresión Dental/clasificación , Fenómenos Químicos , Análisis de Varianza , Ensayo de Materiales , Interpretación Estadística de Datos , Factores de TiempoRESUMEN
En las últimas décadas, la odontología restauradora ha logrado un avance significativo que permite preservar tejido dentario mediante la realización de restauraciones adheridas, directas e indirectas. Este enfoque moderno de Odontología Mínimamente Invasiva, se centra en obtener preparaciones dentarias con un diseño más conservador, basándose en la eficacia de la adhesión al tejido remanente de los biomateriales utilizados. El conocimiento de las características de los sustratos y de los materiales adhesivos, y la comprensión del mecanismo de adhesión es un factor fundamental para alcanzar el éxito clínico...
Asunto(s)
Humanos , Dentina , Esmalte Dental , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Grabado Ácido Dental/métodos , Microscopía Electrónica de Rastreo , Materiales Dentales/clasificación , Polihidroxietil Metacrilato/química , Recubrimientos Dentinarios/clasificación , Resinas Compuestas/químicaRESUMEN
El objetivo del trabajo fue evaluar la estabilidad dimensional lineal de diferentes elastómeros para impresión. Se confeccionó una matriz metálica con sus correspondientes cubetas individuales realizadas con láminas termoplásticas (Marca Sabilex, de 0.125 mm de espesor). Se tomaron tres impresiones con cada material a estamatriz. Se utilizaron tres siliconas por adición: Examix-GC- (AdEx), Aquasil-Dentsply-(AdAq), y Panasil Kettenbach-(AdPa); y tres siliconas por condensación: Densell-Dental Medrano-(CoDe), Speedex-Coltene-(CoSp), y Lastic-Kettenbach-(CoLa). Se realizaron todas las impresiones utilizando dos consistencias: pesada y liviana, con la técnica de un solo tiempo. Luego se tomaron fotografías estandarizadas a diferentes intervalos de tiempo (0, 15,30, 60, 120 minutos; 24 horas; 7 días y 14 días), con una cámara fotográfica digital, utilizando un dispositivo ad-hoc. Las imágenes se analizaron con software de procesamiento de imágenes (Image Tool) realizando la medición de la distancia entre las interseccionesde surcos previamente realizados en la porción superior de la matriz. Los resultados obtenidos fueron analizados mediante Análisis de varianza para mediciones repetidas. La media y el DSinicial y final para todos los materiales fue: AdEx: 1,32 (0,01) y 1,31 (0,00); AdAq: 1,32 (0,00) y 1,32 (0,00); AdPa: 1,327 (0,006) y 1,31 (0,00); CoDe: 1,32 (0,00) y 1,32 (0,01); CoSp: 1,327 (0,006) y 1,31 (0,00); CoLa: 1,327 (0,006) y 1,303 (0,006). La evaluaciónestadística mostró el efecto significativo de las variables material y tiempo. Conclusión: Bajo las condiciones de este estudio podemos concluir que el tiempo afectaría significativamente la estabilidad dimensional lineal de elastómeros para impresiones.
Asunto(s)
Elastómeros/química , Materiales de Impresión Dental/clasificación , Fenómenos Químicos , Técnica de Impresión Dental , Interpretación Estadística de Datos , Factores de TiempoRESUMEN
La adhesión consistente a dentina es de gran importancia en el éxito clínico de los tratamientos restauradores. Algunas de las maniobras utilizadas en los tratamientos odontológicos, involucran la aplicación de materiales con contenido de fenoles. Por eso, es importante evaluar si los materiales de obturación temporaria y elementos empleados en las pulpotomías pueden afectarla. El propósito de este informe es revisar las tendencias y conocimientos actuales respecto de la utilización de materiales y compuestos fenólicos en su relación con resinas reforzadas. En este trabajo se revisa la bibliografía publicada referente a la acción de los compuestos fenólicos sobre las resinas reforzadas en varios de sus aspectos: sus propiedades mecánicas, ópticas y su adhesión a estructuras dentarias. Conclusiones: la evidencia científica referida a la interacción entre compuestos fenólicos y composites es controversial, la decisión de utilización de materiales con contenido de fenoles sobre piezas dentarias que van a recibir un tratamiento restaurados/rehabilitador con composites, debería basarse en el tiempo durante el cual serán aplicados y para su utilización en plazos reducidos considerarse el empleo de materiales libres de fenoles
Asunto(s)
Recubrimiento Dental Adhesivo , Pulpotomía , Cemento de Óxido de Zinc-EugenolRESUMEN
Se determinó el corrimiento de los siguientes selladores endodónticos: Endion-Voco (E), Endomethasone C-Septodont (EM), AH26-Denstply(AH), Bioseal Retard-Ogna (BR), Bioseal Normal-Ogna (BN), Detac Endo-Espe (KE), Procosol Satar Dental (P), Sealer26-Dentsply (S26), Diaket.-Espe (D) y TubliSeal-Kerr (TS), a temperatura y humedad ambiente y a 37ºC 95 por ciento de humedad relativa. Se prepararon 0,07 ml de mazcla de material y se colocaron sobre superficies de vidrio. Se inclinaron a 90º e inmediatamente se registró el desplazamiento producido en la masa del material. Se repitió la medición a los 15 y 60 minutos. Los valores máximos de corrimiento obtenidos para cada material fueron: E: 2.46; EM: 0.57; AH: 6.47; BR: 3.57; BN: 5.17; KE: 1.39; P: 0.79; S26: 1.03; D: 2.48; TS: 0.49. El corrimiento de los selladores endodónticos es afectado por el tiempo, las reacciones que producen su endurecimiento y por las condiciones ambientales
Asunto(s)
Humedad , Fenómenos Químicos , Interpretación Estadística de Datos , TemperaturaRESUMEN
El objetivo de este trabajo fue probar la acción candicida del Parasepto-metil metilparaven (MPV) incorporado a acondicionadores de tejidos para rebasado de prótesis a base de siliconas; se utilizaron dos materiales para rebasado: UFI GEL P (VOCO) y Resil (Subiton Laboratories). Las pruebas se realizaron con los materiales solo (controles) y con el agregado de MPV. Se estudiaron ocho cepas de Cándida, aisladas de cavidad bucal (cuatro Cándida albicans, una Cándida glabrata, una Cándida krusei, una Cándida parapsilosis) y una Rhodotorula sp. Se sembraron 0,5ml de suspensiones homologadas por turbidimetría (9 x 10-7 levaduras/ml), en placas de Petri con 30ml de agar miel. Con sacabocados de 5mm de diámetro se practicaron cuatro perforaciones por caja. En cada nicho se colocaron 0,22mg de los materiales preparados en forma de cilindros UFI GEL P solo-3 y UFI GEL P con 0,023mg de MPV-4, Resil solo-2 y Resil con 0,023mg de MPV-1. En el mismo momento se hicieron dos cilindros adicionales de cada mezcla y por cada cepa, que se mantuvieron a 37gC durante 48hs. Se midieron los halos de inhibición, con un total de 104 lecturas, y se realizó el análisis de varianza. Ufi Gel P y Resil adicionados de MPV poseen acción candicida que se mantiene aún transcurridas las 48hs. El análisis de varianza demostró que entre las cepas de Cándida albicans no hay diferencia estadísticamente significativa, pero sí de éstas con las cepas de Cándida parapsilosis y glabrata. Se utilizó una cepa de Rhodotorula sp. Al compararla con las otras levaduras, ésta demostró igual sensibilidad al MPV. Estos resultados permitirían suponer, que si el MPV carece de toxicidad podría ser un tratamiento alternativo para estomatitis protética. Puede concluirse que, en las condiciones estudiadas, ambos materiales adicionados con MPV poseen acción candicida que se mantiene por cierto tiempo