RESUMEN
PURPOSE: The aim was to study the correlation between cuff size and outcome after implantation of an AMS 800 artificial urinary sphincter. METHODS: A total of 473 male patients with an AMS 800 sphincter implanted between 2012 and 2014 were analyzed in a retrospective multicenter cohort study performed as part of the Central European Debates on Male Incontinence (DOMINO) Project. RESULTS: Single cuffs were implanted in 54.5% and double cuffs in 45.5% of the patients. The cuffs used had a median circumference of 4.5 cm. Within a median follow of 18 months, urethral erosion occurred in 12.8% of the cases and was associated significantly more often with small cuff sizes (P<0.001). Multivariate analysis showed that, apart from cuff size (P=0.03), prior irradiation (P<0.001) and the penoscrotal approach (P=0.036) were associated with an increased erosion rate. Continence rate tended to be highest with median cuff sizes (4–5.5 cm). CONCLUSIONS: Apart from irradiation and the penoscrotal approach, small cuff size is a risk factor for urethral erosion. Results are best with cuff sizes of 4.5–5.5 cm.
Asunto(s)
Humanos , Masculino , Estudios de Cohortes , Análisis Multivariante , Estudios Retrospectivos , Factores de Riesgo , Esfínter Urinario ArtificialRESUMEN
PURPOSE: To analyze perioperative complications and postoperative explantation rates for selected readjustable male sling systems and the perineal single-cuff artificial urinary sphincter (AUS) in a large, contemporary, multi-institutional patient cohort. METHODS: Two hundred eighty-two male patients who underwent implantation between 2010 and 2012 in 13 participating institutions were included in the study (n=127 adjustable male sling [n=95 Argus classic, n=32 Argus T], n=155 AUS). Perioperative characteristics and postoperative complications were analyzed. The explantation rates of the respective devices were assessed using the Fisher exact test and the Mann-Whitney U-test. A Kaplan-Meier curve was generated. Potential features associated with device explantation were analyzed using a multiple logistic regression model (P<0.05). RESULTS: We found significantly increased intraoperative complication rates after adjustable male sling implantation (15.9% [adjustable male sling] vs. 4.2% [AUS], P=0.003). The most frequent intraoperative complication was bladder perforation (n=17). Postoperative infection rates did not vary significantly between the respective devices (P=0.378). Device explantation rates were significantly higher after AUS implantation (9.7% [adjustable male sling] vs. 21.5% [AUS], P=0.030). In multivariate analysis, postoperative infection was a strong independent predictor of decreased device survival (odds ratio, 6.556; P=0.001). CONCLUSIONS: Complication profiles vary between adjustable male slings and AUS. Explantation rates are lower after adjustable male sling implantation. Any kind of postoperative infections are independent predictors of decreased device survival. There is no significant effect of the experience of the implanting institution on device survival.