Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Acta cir. bras ; 39: e391324, 2024. tab, graf, ilus
Artículo en Inglés | LILACS, VETINDEX | ID: biblio-1556671

RESUMEN

Purpose: To develop a new 4/6 infarct nephrectomy (INx) model rat mimicking moderate chronic kidney disease (CKD) and to evaluate its application. Methods: We modified the conventional 5/6 INx rat model to create the 4/6 INx model by ligating the renal artery branch to induce infarction of one-third of the left kidney after right kidney removal and compared biochemically and histologically both models. To demonstrate the application of the 4/6 INx model, the effects of a supplementary compound containing calcium carbonate, chitosan, palm shell activated charcoal etc., that is effective for both CKD and its complications, were compared between both models. Results: Impairment of renal function in the 4/6 INx group was significantly more moderate than in the 5/6 INx group (P < 0.05). The 4/6 INx group showed less histological damage in kidney than in the 5/6 INx group. The supplementary compound did not improve CKD in the 5/6 INx group, but ameliorated elevation of blood urea nitrogen in the 4/6 INx group. Conclusions: We developed the 4/6 INx model, which is more moderate than the conventional 5/6 INx model. This model could potentially demonstrate the effectiveness of drugs and supplements intended to prevent CKD and its progression.


Asunto(s)
Animales , Ratas , Insuficiencia Renal Crónica , Animales de Laboratorio , Microcirugia , Nefrectomía
2.
Acta cir. bras ; 35(10): e202001004, 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1130612

RESUMEN

Abstract Purpose: To modify a surgical catheterization method using the bent needle introducer in small animals. Methods: Eight-week-old male Lewis rats were used in the study. A needle introducer was created by bending a 21G injection needle at 45°. The bent needle introducer was used for catheter insertion into the left femoral artery of the rats under anesthesia. As a control, a catheter was directly inserted into the blood vessel without the introducer. The insertion time of each method was measured. Blood pressure and heart rate were measured 24 h after catheter insertion using the telemetry system. Results: Using the introducer, the catheter was successfully inserted within a short time in all rats. Without the introducer, a longer duration was required for catheter insertion. The frequency of the insertion with no catheter-based errors with the introducer tended to be higher than that without the introducer. The mean arterial pressure and heart rate 24 h after catheter insertion in each group were almost the same. Conclusions: We developed a surgical catheterization method using the introducer in small animals. This could potentially reduce the frequency of the insertion with catheter-based errors and insertion time.


Asunto(s)
Animales , Masculino , Ratas , Cateterismo , Arteria Femoral/cirugía , Ratas Endogámicas Lew , Agujas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA