Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Radiation Oncology Journal ; : 25-34, 2018.
Artículo en Inglés | WPRIM | ID: wpr-741931

RESUMEN

PURPOSE: This study aimed to evaluate the initial outcomes of proton beam therapy (PBT) for hepatocellular carcinoma (HCC) in terms of tumor response and safety. MATERIALS AND METHODS: HCC patients who were not indicated for standard curative local modalities and who were treated with PBT at Samsung Medical Center from January 2016 to February 2017 were enrolled. Toxicity was scored using the Common Terminology Criteria for Adverse Events (CTCAE) version 4.0. Tumor response was evaluated using modified Response Evaluation Criteria in Solid Tumors (mRECIST). RESULTS: A total of 101 HCC patients treated with PBT were included. Patients were treated with an equivalent dose of 62–92 GyE10. Liver function status was not significantly affected after PBT. Greater than 80% of patients had Child-Pugh class A and albumin-bilirubin (ALBI) grade 1 up to 3-months after PBT. Of 78 patients followed for three months after PBT, infield complete and partial responses were achieved in 54 (69.2%) and 14 (17.9%) patients, respectively. CONCLUSION: PBT treatment of HCC patients showed a favorable infield complete response rate of 69.2% with acceptable acute toxicity. An additional follow-up study of these patients will be conducted.


Asunto(s)
Humanos , Carcinoma Hepatocelular , Estudios de Seguimiento , Hígado , Terapia de Protones , Protones , Radioterapia , Criterios de Evaluación de Respuesta en Tumores Sólidos
2.
Radiation Oncology Journal ; : 337-343, 2015.
Artículo en Inglés | WPRIM | ID: wpr-70159

RESUMEN

PURPOSE: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. MATERIALS AND METHODS: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. RESULTS: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. CONCLUSION: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.


Asunto(s)
Humanos , Ciclotrones , Helio , Corea (Geográfico) , Metalurgia , Aceleradores de Partículas , Posicionamiento del Paciente , Terapia de Protones , Protones , Oncología por Radiación , Sistema Respiratorio , Seúl
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA