Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Añadir filtros








Intervalo de año
1.
Audiol., Commun. res ; 20(3): 239-245, jul.-set. 2015. tab
Artículo en Portugués | LILACS | ID: lil-761559

RESUMEN

Objetivo Caracterizar a variabilidade teste-reteste com fones supra-aurais e fones de inserção e comparar os limiares auditivos tonais entre os transdutores.Métodos Foram selecionados 74 indivíduos de ambos os gêneros, com limiares auditivos normais e curvas timpanométricas do tipo A. Todos os indivíduos foram submetidos à anamnese, meatoscopia, audiometria tonal por via aérea, ora com o fone supra-aural, ora com o fone de inserção, e logoaudiometria. Após esta primeira avaliação, foi realizada a medida de imitância acústica. Por fim, os procedimentos de audiometria tonal foram repetidos.Resultados O fone supra-aural produziu maior variabilidade teste-reteste, quando comparado com o fone de inserção. Já na comparação dos transdutores, verificou-se, tanto na primeira, quanto na segunda testagem, que as respostas mostraram-se ora semelhantes, ora favorecendo um ou outro transdutor.Conclusão Há maior variabilidade teste-reteste com o fone supra-aural do que com o fone de inserção. No entanto, foram verificados melhores limiares na condição reteste, para ambos os transdutores.


Purpose To characterize the test-retest variability with supra-aural and insert earphones and compare the pure tone thresholds between the transducers.Methods Seventy-four individuals of both genders with normal hearing and tympanometric curve of type A were selected. All subjects underwent anamnesis, meatoscopy, air conduction pure tone audiometry, either with the supra-aural earphone, or with insert earphone and speech audiometry. After this initial evaluation Acoustic Impedance Testswere performed. Finally, pure tone audiometry procedures were repeated with both transducers.Results Supra-aural earphone produced higher test-retest variability when compared to the insert earphones. Comparing a transducer with each other, the responses were sometimes similar and sometimes favoring one or the other transducer considering the first and second evaluations.Conclusion There is a greater test-retest variability with supra-aural earphones comparing with insert earphones. However, better thresholds were obtained in the retest condition for both transducers.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Audiometría de Tonos Puros , Umbral Auditivo , Prueba del Umbral de Recepción del Habla , Transductores , Estudios Transversales , Conducto Auditivo Externo/diagnóstico por imagen , Anamnesis , Pruebas de Discriminación del Habla
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA