Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Medical Instrumentation ; (6): 6-9, 2013.
Artículo en Chino | WPRIM | ID: wpr-342898

RESUMEN

Three-electrode testing method was used to investigate the effect of temperature on electrode impedance, and the pH shifts in saline solution resulting from the electrical stimulation were also determined. Experiments in PBS (phosphate buffered solution) solution showed that the electrode impedance was almost invariable at the human body temperature range (35 degrees C-40 degrees C). And the experiments in unbuffered saline solution showed that pH shifts decreased from 0.03 to 0.005 when the frequency of biphasic charged-balanced pulses increased from 1 Hz to 100 Hz. Even stimulated by monophasic pulses (frequency is 15 Hz, amplitude is 50 microA), the stimulus-induced pH shift of electrode only varies 0.15 (anodic pulse current increased 0.15 and cathodic pulse current decreased 0.15).


Asunto(s)
Electroquímica , Ojo Artificial , Ensayo de Materiales , Microelectrodos , Prótesis e Implantes
2.
Chinese Journal of Medical Instrumentation ; (6): 407-410, 2013.
Artículo en Chino | WPRIM | ID: wpr-264175

RESUMEN

The paper proposed a new method to design and fabricate a flexible neural microelectrode arrays (MEA) for retinal prosthesis, the ion-beam technology was introduced to decrease the width of conductive wires and the distances between wires, a high density MEA (120 microelectrodes with a matrix of 10 x 12) was fabricated on a single layer of polymer from this. The MEA was proved to possess a fine electrochemical property. In vitro test, the average impedance of MEA on 1 kHz was 16 k omega +/- 2 k omega and the average phase difference was -85 degrees +/-30 degrees.


Asunto(s)
Sistemas Microelectromecánicos , Microelectrodos , Diseño de Prótesis , Prótesis Visuales
3.
Chinese Journal of Medical Instrumentation ; (6): 399-402, 2010.
Artículo en Chino | WPRIM | ID: wpr-330552

RESUMEN

This paper proposed a new design on multi-layer flexible microelectrode arrays (MEA) of epiretinal prosthesis, as well as a set of automatic testing system to evaluate and analyze the MEA. Experiment results showed that the MEA was satisfying on both flexibility and impedance and the multi-layer design didn't introduce significant differences.


Asunto(s)
Análisis por Micromatrices , Microelectrodos , Prótesis e Implantes , Diseño de Prótesis , Implantación de Prótesis , Retina
4.
Chinese Journal of Medical Instrumentation ; (6): 355-359, 2010.
Artículo en Chino | WPRIM | ID: wpr-281084

RESUMEN

This review paper presents the current research progress, challenges and future development on microelectrode array of retinal prosthesis, including epi-retinal and sub-retinal implants.


Asunto(s)
Microelectrodos , Diseño de Prótesis , Prótesis Visuales
5.
Chinese Journal of Radiation Oncology ; (6)1993.
Artículo en Chino | WPRIM | ID: wpr-679104

RESUMEN

Objective To improve the set up accuracy for patients by MED TEC thermoplastic sheet. Methods First, a reference positioning line was scored on the supporting board of MEC TEC. Then, lines on the patient body were marked according to the reference positioning line. After fastening MED TEC thermoplastic sheet, CT top view imagines of patients who were immobilized with MED TEC thermoplastics sheet on the CT scanner were then drawn. The results by PC graphics software were analysed. Results A total of 57 cases was studied. Deviation in 52 (91.2%) cases was less than 3?mm. The cause of the with deviation exceeding 5?mm were all found.Conclusion Using the right method is very important. Thus, results with satisfactory deviations could be obtained when the set up are repeated.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA