RESUMEN
Objectives:The uses of devices of electromagnetic waves(EMWs)are increasing day by day.Similarly,the gen-eration of the waves is increasing.The frequency spectrum of the generation of waves is also increased.In this manuscript,an analysis of the high frequency EMWs has been made by the electric fields generated due to the exposure of 5th generation(5 G)of mobile phones. Methods:Due to the emission of waves from the towers,the electric field is generated around the transmission tower of mobile phones.The electric fields are computed by the power of the transmission tower.The electric fields across the biological tissues/cells are also computed when the EMWs penetrate inside the body.The electric fields are made across the organs of different depths inside the body. Results:The induced electric fields inside the organs of the human beings are responsible for the absorption of energy from high frequency EMWs.The absorbed amount of energy from high frequency waves may become the cause of harmful effects on the life of organs of human beings. Conclusion:In this manuscript,after analysis of the computed electric fields inside the organs of human beings,it is concluded that the EMWs of 5 G spectrum of mobile phone towers may more harmful for the life of organs as 4th generation(4 G)spectrum of mobile phone waves.The energy absorption by the 4 G spectrum is lower than 5 G spectrum due to the range of frequency of waves.The effects on the pancreas,retina,skin,intestine,spleen,stomach and uterus are more than low water content organs like nails,bone,teeth etc.
RESUMEN
Resumen Los índices térmico y mecánico son estimadores de riesgo fetal en una ecografía y se deben controlar sus valores minimizando la exposición. Comparamos los valores de los índices térmico y mecánico obtenidos en exámenes ecográficos obstétricos de pacientes gestantes, con el valor recomendado por la comunidad internacional. Se realizó la estimación de estos índices en 421 ecografías obstétricas en 2019. Los valores fueron comparados entre ellos y con el valor recomendado para cada índice y según el modo de visualización (B, Doppler color y Doppler espectral). Del total de la muestra, para el índice térmico en modo Doppler color un 0,24% superó el valor estándar recomendado y en modo Doppler espectral un 2,85%. Para el índice mecánico se sobrepasó el valor recomendado en modo B en un 11,16%, en un 8,08% en modo Doppler color y, por último, en un 0,48% para el modo Doppler espectral. Los índices mecánico y térmico en esta muestra de exámenes ecográficos obstétricos se encuentran en promedio bajo el valor de referencia. Sin embargo, existe un número importante de casos en que se superan las normas, lo que debe ser una voz de alerta para la comunidad médica.
Abstract The thermal and mechanical indices are the best estimators of fetal risk in an ultrasound and their values should be controlled in order to minimize exposure as much as possible. We compared the values of the thermal and mechanical indices obtained in obstetric ultrasound examinations of pregnant patients, with the value recommended by the international community. These indices were estimated in 421 obstetric ultrasounds during 2019. The estimated values were compared with each other and with the recommended value for each index and according to the display mode (B, color Doppler and spectral Doppler). Of the total sample, for the thermal index in color Doppler mode, 0.24% exceeded the recommended standard value and 2.85%. in spectral Doppler mode. For the mechanical index, the recommended value was exceeded in B mode by 11.16%, in 8.08% in color Doppler mode and, finally, by 0.48% for spectral Doppler mode. The mechanical and thermal indices in this sample of obstetric ultrasound examinations are on average below the reference value. However, there is a significant number of cases in which the standards are exceeded, which should be a warning to the medical community.