1.
Chinese Journal of Radiological Medicine and Protection ; (12): 534-538, 2019.
Artículo en Chino | WPRIM | ID: wpr-755004

RESUMEN

Objective To investigate the effect of CareDose 4D combined with Care kV on CT pulmonary ground glass nodule ( GGN) with respect to quality and radiation dose. Methods The thoracic model containing 6 GGN was performed by using 7 low-dose schemes. The CareDose 4D + Care kV was adopted in scheme 1. In schemes 2, 3 and 4, the tube voltage was 120 kV, and the tube current 30, 20 and 10 mAs respectively. In schemes 5, 6 and 7, the tube voltage was 100 kV, and the tube current was 30, 20 and 10 mAs, respectively. The image quality [ CT value, contrast noise ratio ( CNR) , noise value (SD) and subjective score] and effective dose (E) were compared. Results There was no statistically significant difference in CT value of GGN among different schemes (P>0. 05). The SD of scheme 1 was higher than those of schemes 2, 3 and 5, but lower than those f scheme 7, while the CNR of scheme 1 was lower than those of schemes 2, 3 and 5, but higher than that of scheme 7 ( t=13. 020, 9. 560, 8. 120,-5. 720, -7. 849, -5. 192, -4. 130, 1. 361,P<0. 05). SD and CNR of scheme 1 were not significantly different from those of scheme 4 and 6 ( P>0. 05) . The subjective scores of each GGN of schemes 1, 2, 3, 5 and 6 was over 3 points, but and the subjective scores of one GGN of each of schemes 4 and 7 were below 3 points. The value E of the scheme 1 was reduced by 63. 0%, 44. 4%, 38. 8%, and 9. 1%, compared with the schemes 2, 3, 5 and 6, respectively. Conclusions CareDose 4D combined with Care kV in low-dose lung CT scan can ensure the image quality of GGN and reduce the radiation dose effectively.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 389-392, 2017.
Artículo en Chino | WPRIM | ID: wpr-610067

RESUMEN

Objective To investigate the feasibility and clinical value of anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV in chest CT scan.Methods A total of 60 patients of clinical diagnosis with lung tumor were enrolled.Those patients were randomly divided into test group and control group.Control group underwent a scan protocol with lateral scout scan combined with Care Dose 4D and Care kV,while anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV were performed in test group.The signal-to-noise ration (SNR),contrast-to-noise ratio (CNR),and overall image quality of two groups of images and diseased tissues were analyzed and evaluated by two high-grade radiologists using double-blind method.Effective doses (E) were also calculated.Results All the 60 patients had successfully completed the chest CT scans.Test group overall image quality (4.57 ± 0.45) and control group overall image quality (4.73 ± 0.45) had no statistically significant difference (P > 0.05).The control group image SNR,CNR and diseased tissue SNR,CNR compared with test group had no statistical significance difference (P > 0.05).The difference of the volume CT dose index (CTDIvol),dose-length product (DLP) and effective dose (E) of test group and control group was statistically significant (t =8.514,8.464,8.464,P < 0.001).Compared with control group,the effective dose of test group decreased by 33.3%.Conclusions Compared with lateral scout scan,the technology of anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV can decrease radiation dose without reducing the image quality.This technology can therefore be considered as a regular imaging modality for chest CT scan.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 68-72, 2017.
Artículo en Chino | WPRIM | ID: wpr-507049

RESUMEN

Objective To study the application of the intelligent optimum tube voltage ( Care kV) combined with automatic tube current ( Care Dose 4D) technique in dual source CT scanning for the abdomen .Methods 180 adult patients underwent whole abdominal CT examination from February 2016 to March 2016 of were selected as the retrospective research objects .On the basis of reference mAs of the image quality the patients were divided into three groups using completely randomized grouping method with 60 patients in each group, such as 250 mAs group, 200 mAs group, and 150 mAs group.The other scanning parameters and image reconstruction parameters were the same .The liver parenchyma CT values and image noise( SD) at the second hepatic portal level were measured .The signal-to-noise ratios ( SNR) in the three groups were compared as well as contrast to noise ratio ( CNR ) , noise ( SD ) , the average volume CT dose index (CTDIvol), dose length product (DLP) and effective dose(E).Results The kV and mAs values in the plain scan , arterial phase scan and portal phase scan in the three groups of patients had statistically significant differences(F=35.25, P0.05).In 250 mAs group and 150 mAs group, the SNR and the noise of plain scan and arterial phase images had no statistically significant difference ( F=1.98, P>0.05) , and SNR of portal phase images and CNR of three phases had statistically significant difference (F=27.64, P0.05), and the SNR and CNR of portal phase images had significant difference (F=19.63, P<0.05).Conclusions For the combined use of Care kV and Care dose 4D,it is feasible to select appropriate reference mAs in reducing radiation dose without sacrificing imaging quality .

4.
The Journal of Practical Medicine ; (24): 1813-1816, 2016.
Artículo en Chino | WPRIM | ID: wpr-494525

RESUMEN

Objective Based on the teeth in vitro skull specimen to investigate the feasibility and accuracy of CARE kV CT scan for reducing radiation dose. Methods Of eight fixed and preserved skull teeth were scanned repeatedly in groups of A, B, C. In expose factors of 100 kVp/150 mAs in conventional scanning of group A, open CARE Dose 4D scan of group B and CARE kV scan of group C. We assessed the radiation dose in the group A, B and C, the average CT values of the images, noise, SNR, CNR and subjective ratings. Results Three groups of actual scan tube current, tube voltage and radiation dose were statistically significant (P 0.05). Conclusion CARE kV technology based on the use specimens tooth can reduce the radiation dose, protect image quality, and be consistent to the reports of previous researches.

5.
Chinese Journal of Radiological Medicine and Protection ; (12): 664-667, 2013.
Artículo en Chino | WPRIM | ID: wpr-439251

RESUMEN

Objective To explore the application of CARE kV technique in the adult chest CT and the value of reducing radiation dose.Methods Sixty-nine patients were divided into two groups by random number generators:group A(39 cases) and group B(30 cases).Group A was examined by using CARE kV technique and group B was examined at routine 120 kV.CT dose index(CTDIvol),dose length product (DLP) and effective dose (E) were compared between the two groups,and analyzed the correlation between tube voltage selection and patient body mass index (BMI) of group A was analyzed.Results The average CTDIvol [(11.00 ± 3.89) mGy],DLP[(294.05 ± 91.17) mGy·cm] and E[(4.12 ± 1.28) mSv] of group A were lower than those of group B (16.64 ± 1.20) mGy,[(475.99 ± 41.16) mGy · cm],[(6.66 ±0.58) mSv].With statistically significant difference (t =-7.653,-10.151,-10.150,P < 0.05).Compared with routine 120 kV technique (group B),the CARE kV technique (group A) could reduce the total radiation dose about 38.14%.Compared obese patients(BMI≥28 kg/m2) with non-obese patients in group A and B,the mean E of non-obese patients was lower than that of obese patients in group A,which reduced the total E about 31.74% (t =4.322,P <0.05),while E in group B was no significant different between non-obese patients and obese patients.Conclusions In adult chest CT,CARE kV technique can select optimum scanning voltage automatically according to the patients with different BMI and anatomical regions,which can reduce the overall radiation dose while maintaining image quality.