Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. J. Pharm. Sci. (Online) ; 53(3): e00012, 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-889392

RESUMEN

ABSTRACT A rapid, sensitive, and accurate high performance liquid chromatography for the determination of Axitinib (AN) in rabbit plasma is developed using crizotinibe as an internal standard (IS). Axitinib is a tyrosine kinase inhibitor, used in the treatment of advanced kidney cancer, which works by slowing or stopping the growth of cancer cells. The chromatographic separation was performed on a Waters 2695, Kromosil (150 mm × 4.6 mm, 5 µm) column using a mobile phase containing buffer (pH 4.6) and acetonitrile in the ratio of 65:35 v/v with a flow rate of1 mL/min. The analyte and internal standard were extracted using liquid-liquid extraction with acetonitrile. The elution was detected by photo diode array detector at 320 nm.The total chromatographic runtime is 10.0 min with a retention time for Axitinib and IS of 5.685, and 3.606 min, respectively. The method was validated over a dynamic linear range of 0.002-0.2µg/mL for Axitinib with a correlation coefficient of r2 0.999.


Asunto(s)
Conejos , Cromatografía Líquida de Alta Presión/métodos , Estudio de Validación , Proteínas Tirosina Quinasas/antagonistas & inhibidores , Neoplasias Renales/tratamiento farmacológico
2.
Braz. j. pharm. sci ; 51(2): 439-447, Apr.-June 2015. tab, ilus
Artículo en Inglés | LILACS | ID: lil-755052

RESUMEN

This study describes the development and validation of a novel 96-microwell-based high throughput spectrophotometric assay for pharmaceutical quality control of crizotinib (CZT), a novel drug for the treatment of non-small cell lung cancer. We examined the reaction between CZT and 1,2-naphthoquinone-4-sulphonate, a chromogenic reagent. A red-colored product showing a maximum absorption peak (λmax) at 490 nm was produced in an alkaline medium (pH 9). We examined stoichiometry of the reaction and postulated the reaction mechanism. To our knowledge, this is the first study to describe a color-developing reaction for the proposed assay. The reaction was performed in a 96-microwell plate, and the absorbance of the colored product was measured using an absorbance reader at 490 nm. Under optimized reaction conditions, Beer's law, which shows a correlation between absorbance and CZT concentration, was obeyed in the range of 4-50 µg/well with an appropriate correlation coefficient (0.999). The limits of detection and quantification were 1.73 and 5.23 µg/well, respectively. The assay showed high precision and accuracy. The proposed assay was applied successfully for the determination of CZT in capsules. Thus, the assay proposed in this study is practical and valuable for routine application in pharmaceutical quality control laboratories...


Este estudo descreve o desenvolvimento e a validação de um novo ensaio espectrofotométrico em larga escala em 96 micropoços para o controle farmacêutico de crizotinibe (CZT), novo fármaco para o tratamento de câncer de pulmão de células não pequenas. Examinamos a reação entre o CZT e o 4-sulfonato de 1,2-naftoquinona, um reagente cromogênico. Obteve-se, em meio alcalino (pH 9), produto vermelho, com absorção máxima (λmax) em 490 nm. Examinamos a estequiometria da reação e propusemos mecanismo de reação. Este, segundo nosso conhecimento, é o primeiro estudo para descrever reação de desenvolvimento de cor para o ensaio proposto. A reação foi realizada em placas de 96 micropoços e mediu-se a absorbância do produto colorido utilizando-se leitor de absorbância a 490 nm. Sob condições otimizadas de reação, a lei de Beer, que mostra a correlação entre a absorbância e a concentração de CZT, foi obedecida na faixa de 4-50 µg/poço, com coeficiente de correlação apropriado (0,999). Os limites de detecção e de quantificação foram, respectivamente, 1,73 e 5,23 µg/poço. O ensaio mostrou alta precisão e exatidão. O ensaio proposto foi aplicado com sucesso para a determinação de CZT em cápsulas e é prático e válido para a aplicação de rotina em laboratórios de controle farmacêutico...


Asunto(s)
Humanos , Análisis Espectral/análisis , Análisis Espectral/métodos , Proteínas Tirosina Quinasas , Proteínas Tirosina Quinasas/antagonistas & inhibidores , Proteínas Tirosina Quinasas/farmacología , Carcinoma de Pulmón de Células no Pequeñas , Control de Calidad/métodos , Químicos de Laboratorio/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA