Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
International Eye Science ; (12): 567-572, 2023.
Artículo en Chino | WPRIM | ID: wpr-965778

RESUMEN

AIM: To investigate the short-term visual quality outcomes after femtosecond laser small incision lenticule extraction(SMILE)and evolution implantable collamer lens(EVO-ICL)implantation for the correction of moderate myopia.METHODS: Prospective control study. A total of 51 cases(51 eyes)with moderate myopia who underwent SMILE or EVO-ICL implantation surgery at Weifang Eye Hospital from April 2021 to February 2022 were selected. They were divided into SMILE group(30 patients, 30 eyes)and EVO-ICL group(21 patients, 21 eyes)according to the surgical methods. The changes of visual acuity [uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA)], diopter [spherical equivalent(SE)] and related parameters of optical quality analysis system(OQAS Ⅱ)were observed before surgery and at 1wk, 1 and 3mo after surgery, and the quality of vision(QoV)questionnaire was completed.RESULTS: At 3mo after surgery, the safety index(postoperative CDVA/preoperative CDVA)of SMILE gruop and EVO-ICL group were 1.20(1.00, 1.20)and 1.20(1.00, 1.38), respectively, the efficacy index(postoperative UDVA/preoperative CDVA)were 1.00(1.00, 1.20)and 1.00(1.00, 1.20), respectively, and the percentage of SE within ±0.50D was 87% and 100%, respectively. In SMILE group, the objective scattering index(OSI)was increased after surgery, while modulation transfer function cutoff frequency(MTF cutoff), contrast visual acuity(VA)100%, and VA20% at 1wk and 1mo after surgery, and Strehl ratio(SR)and VA9% at each time point after surgery were all decreased compared with those before surgery(all P<0.05). The OSI, MTF cutoff, SR and VA of EVO-ICL group showed no difference at each time point after surgery compared with those before surgery(all P>0.05). The most common visual symptoms after SMILE and EVO-ICL implantation were visual haze and halos, respectively.CONCLUSION: Both SMILE and EVO-ICL implantation have good safety, efficacy and predictability in the short term after the correction of moderate myopia. Both groups had visual symptoms after surgery, but the overall satisfaction of patients was high. Furthermore, EVO-ICL implantation has better objective visual quality performance.

2.
International Eye Science ; (12): 480-486, 2021.
Artículo en Chino | WPRIM | ID: wpr-873449

RESUMEN

@#AIM: To compare the clinical effects of FS-LASIK and ICL implantation.<p>METHODS: From January 2015 to January 2020, used computer to search the clinical contrast test of FS-LASIK and ICL implantation published in CNKI database, Wanfang database, Chongqing VIP Chinese Sci tech journal full-text database, China Bioligy Medicine disc(CBMdisc), Cochrane Library, PubMed, MEDLINE and other databases,using rev-man5.3 statistical software for Meta-analysis and statistical processing.<p>RESULTS: Totally 11 studies were brought into the analysis, including 673 patients and 1 301 operative eyes. The results of Meta-analysis showed that there was no statistical significance in the safety, objective visual quality, spherical equivalent degree, cylinder, diopter of correction, trefoil aberration and coma aberration of FS-LASIK and ICL implantation after operation, but there was statistical significance in the effectiveness, total higher-order aberration, spherical aberration and contrast sensitivity of FS-LASIK and ICL implantation after operation.<p>CONCLUSION: Compared with ICL implantation, the total high-order aberrations and spherical aberrations of FS-LASIK are larger, and the contrast sensitivity is lower. The ICL implantation has more clinical-effect superioity than FS-LASIK, meanwhile it has reversibility and less complications.

3.
International Eye Science ; (12): 1240-1243, 2021.
Artículo en Chino | WPRIM | ID: wpr-877394

RESUMEN

@#AIM:To evaluate the effect of the vault on corneal endothelial cells after implantation of central hole implantable lens(ICL)V4c without viscoelastic microincision.<p>METHODS: Prospective non-randomized controlled study. A total of 70 patients(137 eyes)with myopia who underwent ICL V4c implantation in our hospital from November 2017 to February 2018 were divided into low vault group(100μm<vault≤250μm, 37 eyes), medium vault group(250μm<vault≤750μm, 69 eyes)and high vault group(750μm<vault≤900μm, 31 eyes)according to the size of postoperative vault. After 1a of follow-up, the changes of corneal endothelial cell count and anterior chamber parameters were observed.<p>RESULTS:At 1wk after operation, the anterior chamber depth, anterior chamber volume and anterior chamber angle of the three groups were all decreased compared with those before operation(<i>P</i><0.05). There was no significant difference in corneal endothelial cell count among the three groups at different time points before and after surgery. The loss rate of corneal endothelial cells in the low vault group at 1wk, 3mo and 1a after surgery were about 1.2%, 1.5% and 1.7%, respectively. The loss rate of corneal endothelial cells in the middle vault group were about 0.5%, 0.7% and 1.0%, respectively. The loss rate of corneal endothelial cells in the high vault group were about 1.1%, 1.3% and 1.4%, respectively.<p>CONCLUSION:The vault in early period after ICL V4c implantation without viscoelastic microincision had no significant effect on corneal endothelial cells.

4.
International Eye Science ; (12): 1222-1225, 2020.
Artículo en Chino | WPRIM | ID: wpr-822247

RESUMEN

@#AIM: To compare the objective optical quality of high myopic patients between SMILE and V4c ICL implantation.<p>METHODS: This was a prospective control study. Thirty-eight patients underwent SMILE and thirty-two patients underwent V4c ICL implantation with high myopia were chosen for this study. Uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA)and refractive situation were evaluated preoperatively, at 1wk, 1mo, 3mo and 6mo postoperatively. The objective scattering index(OSI), strehl rate(SR)and modulation transfer function(MTF)cut off frequency were measured by the double-pass optical quality system at the same time.<p>RESULTS: No significant difference of spherical equivalent(SE), UCVA and BCVA was found between SMILE group and V4c ICL implantation group at all time points. At 1wk and 1mo after operation, the OSI values of two groups were significantly higher than pre-operation(<i>P</i><0.01). OSI values of two groups returned to baseline at 3mo after operation. The MTF cut off frequency of both groups decreased significantly at 1wk after operation(<i>P</i><0.05)and recovered to baseline at 1mo after operation, no significant difference was found between two group at all time points(<i>P</i>>0.05).<p>CONCLUSION: Both SMILE and V4c ICL implantation can obtain good visual acuity and objective optical quality.

5.
International Eye Science ; (12): 1419-1423, 2019.
Artículo en Chino | WPRIM | ID: wpr-742696

RESUMEN

@#AIM: To investigate the changes of ganglion cell-inner plexiform layer and retina thickness in myopic eyes after intraocular collamer lens(ICL)implantation using quantitative optical coherence tomography(OCT).<p>METHODS:A prospective study enrolled 41 myopic eyes of 26 patients which underwent ICL implantation(average age: 28.19±6.28 years). Aaxial length(AL), uncorrected visual acuity(UCVA), refractive diopter(RD), best corrected visual acuity(BCVA), intraocular pressure(IOP)and OCT were measured and compared in all patients before and after surgery. Optical coherence tomography(OCT)was used to image central retinal thickness(CRT)and ganglion cell-inner plexiform layer thickness(GCT). The changes between pre-and postoperative were analyzed by repeated measures analysis of variance(ANOVA). Least significant difference test was used to compare the specific time points after operation with those before operation.<p>RESULTS: Compared with the preoperative data, all the patients showed significant improvements in the postoperative UCVA and BCVA(<i>P</i><0.05). However, there was no statistical significance in IOP. CRT were 273.20 ±25.48, 274.07±27.64, 277.85 ±25.49, and 275.99 ±24.68μm before and after surgery, respectively, while GCT were 85.31 ±5.19, 88.95±6.87, 87.73±4.23, and 87.45±4.59μm, respectively, with statistically significant changes(all <i>P</i> <0.05). Among them, CRT increased in one month after operation, with statistical significance(<i>P</i><0.01). GCT increased in 1wk, 1mo and 3mo after operation, with statistical significance(<i>P</i><0.05). The changes of GCT in 1wk after operation was positively correlated with AL(<i>r</i>s=0.529, <i>P</i>=0.001).<p>CONCLUSION:ICL implantation for myopic eyes has good efficacy and safety, but macular area changes will occur after surgery, which need to be paid attention to.

6.
International Eye Science ; (12): 1928-1930, 2019.
Artículo en Chino | WPRIM | ID: wpr-756888

RESUMEN

@#AIM: To evaluate the clinical efficacy of the posterior chamber intraocular lens(ICL)implantation for high myopia by the double-pass optical quality analysis system II(OQAS II).<p>METHODS: A total of 26 eyes of 52 patients with high myopia admitted to the First Affiliated Hospital of Anhui Medical University from December 2017 to December 2018 were selected. All patients underwent ICL implantation. Follow-up to obtain the best corrected visual acuity(BCVA)of all patients. And a series of parameters, such as uncorrected visual acuity(UCVA), object scatter index(OSI), modulation transfer function(MTF), Strehl ratio(SR)and Predicted VA of 100%,20% and 9%,were obtained before and 1wk,1 and 3mo after operation.<p>RESULTS: Compared with preoperative UCVA and BCVA, the 1wk, 1 and 3mo UCVA were better than preoperative and gradually improved, and the differences were statistically significant(<i>P</i><0.01). Compared with OSI, MTF, SR and Predicted VA 100%, 20% and 9% before operation, the situation improved at 1wk,1 and 3mo after operation, with statistical significance(<i>P</i><0.01).<p>CONCLUSION: ICL implantation can effectively correct high myopia and improve UCVA. Through OQAS II analysis, OSI was reduced after ICL implantation. The postoperative MTF, SR and Predicted VA of 100%, 20% and 9% higher than those before surgery. The visual quality of patients with high myopia was improved after ICL implantation.

7.
Recent Advances in Ophthalmology ; (6): 867-871, 2017.
Artículo en Chino | WPRIM | ID: wpr-607202

RESUMEN

Objective To assess the optical quality after implantation of the intraocular contact lens with and without a central hole for high myopia.Methods A total of 23 patients (41eyes),including 11 patients (21 eyes) implanted with V4 ICL (V4 ICL group) and 12 patients (20 eyes) with V4 c ICL implantation (V4 c ICL group) were enrolled in this research.Six months after operation,slit lamp microscope was used to check the anterior segment,and LogMAR chart was to test uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA).Moreover,automatic refractometer was to measure the spherical equivalent (SE) and astigmatic diopter before and after the operation.OQAS parameters included objective scattering index (OSI),modulation transfer function (MTF),Stryrby (SR),OQAS values (OV100%,OV20%,OV9%) at different contrast level were examined.Results In both groups,the parameters of UCVA (logMAR),BCVA (logMAR),SE and astigmatic diopter at 6 months after operation were significantly improved compared with before operation,with significant difference (all P < 0.05).There was no siguificant difference in the UCVA,BCVA,SE and astigmatic diopter between the two groups before operation and 6 months after operation (all P > 0.05).Moreover,the values of MTFcutoff,SR,and OQAS visual parameters (OV100%,OV20% and OV9%) at 6 months after operation were significantly higher than those before operation between the two groups,and the difference was statistically significant (all P < 0.05),while OSI was lower than preoperative data,but there was no significant difference in OSI between the two groups (P < 0.05).There was no significant difference in OQAS visual quality parameters,including OSI,MTFcutoff,SR,and OV100%,OV20% and OV9%,between the two groups (all P > 0.05).Conclusion It is safe and effective of the two types of intraocular contact lens implantation for correction of high myopia,and V4 c ICL can achieve the similar visual quality to the traditional V4 ICL.

8.
Journal of the Korean Ophthalmological Society ; : 835-846, 2015.
Artículo en Coreano | WPRIM | ID: wpr-27647

RESUMEN

PURPOSE: To determine the risk factors and incidence of cataract formation over a long-term mean follow-up of 7.5 years after type V4 implantable collamer lens (ICL) implantation. METHODS: We analyzed the preoperative, 3-month postoperative, 3-year postoperative, and last follow-up data of 228 eyes (118 patients) with mean preoperative spherical equivalent of -12.7 D and minimum postoperative follow-up of 3 years. Additionally, we determined the risk factors for cataract formation and calculated the 10.3 year cumulative cataract formation rate and 10.3 year cumulative cataract surgery rate using a survival curve. RESULTS: After type V4 ICL implantation with minimum follow-up of 3 years, the calculated 10.3 year cumulative cataract formation rate was 20% and actual cataracts developed in 34 eyes (14.9%). The 10.3 year cumulative cataract surgery rate was 12% based on a survival curve and actual cataract surgery was performed in 12 eyes (5.3%). The risk factors for cataract formation were age (odds ratio [OR] = 1.10, p = 0.00), preoperative spherical equivalent (OR = 0.90, p = 0.00), crystalline lens thickness (OR = 9.54, p = 0.00), axial length (OR = 1.33, p = 0.00), 3 months postoperative vault (OR = 0.50, p = 0.03), and existence of peripheral touch between ICL optic margin and crystalline lens at last follow-up (OR = 7.84, p = 0.00). CONCLUSIONS: We suggest one of the main risk factors for cataract formation after ICL implantation is decreased central vault and peripheral touch between ICL optic margin and crystalline lens.


Asunto(s)
Catarata , Estudios de Seguimiento , Incidencia , Cristalino , Factores de Riesgo
9.
Journal of the Korean Ophthalmological Society ; : 784-788, 2015.
Artículo en Coreano | WPRIM | ID: wpr-226682

RESUMEN

PURPOSE: To report a case of decreased endothelial cell density 7 years after posterior chamber phakic intraocular lens implantation. CASE SUMMARY: A 45-year-old man with high myopia combined with astigmatism was treated with Toric implantable Collamer Lens (ICL) implantation. The patient's best corrected visual acuity was 0.7 in both eyes before the operation. After the treatment, his uncorrected visual acuity was 0.9 and corrected visual acuity was 1.0 in both eyes, indicating an improvement in visual function. Preoperative endothelial cell density measured 3,063 cells/mm2 in the right eye and 3,126 cells/mm2 in the left eye. At 5 years postoperatively, measurements were 2,897 cells/mm2 in the right eye and 2,974 cells/mm2 in the left, showing little change. However, a 6-year postoperative measurement of 2,198 cells/mm2 in the right eye and 2,803 cells/mm2 in the left showed a slight decrease in endothelial cell density in the right eye, and a follow-up measurement one year later displayed a rapid decline to 1,272 cells/mm2 in the right eye and 2,852 cells/mm2 in the left eye. The Toric ICL lens was removed from the right eye and phacoemulsification and posterior chamber intraocular lens implantation was performed. Two-month postoperative endothelial cell density was 1,257 cells/mm2 and endothelial cell damage from the operation itself was minimal. CONCLUSIONS: ICL implantation may cause complications related to corneal endothelial cells as well as glaucoma. Patients should receive regular follow-up examinations for endothelial cell density.


Asunto(s)
Humanos , Persona de Mediana Edad , Astigmatismo , Células Endoteliales , Estudios de Seguimiento , Glaucoma , Implantación de Lentes Intraoculares , Lentes Intraoculares , Miopía , Facoemulsificación , Lentes Intraoculares Fáquicas , Agudeza Visual
10.
Korean Journal of Ophthalmology ; : 130-132, 2008.
Artículo en Inglés | WPRIM | ID: wpr-67681

RESUMEN

We report a case of recurrent occlusion of laser iridotomy (LI) sites after a Visian ICL (Implantable contact lens version 4, Staar Surgical AG, Nidau, Switzerland) implantation. A 45-year-old woman had bilateral ICL implantation after placement of two peripheral LI sites in each eye to prevent pupillary block. At one month after the operation, severe narrowing or occlusion of four LI sites occurred. After this, although she received four additional LIs at postoperative months 1, 6, 9 and 10 in both eyes, the narrowing or occlusion recurred. Mild chronic anterior chamber inflammation was observed intermittently throughout the follow-up period. We performed clear lens extraction in both eyes (at postoperative month 11 in the left eye and month 26 in the right eye) due to recurrent occlusion of the LI sites and excess trabecular meshwork pigment deposition presumably caused by the four repeated LIs. Recurrent obstruction of LI sites can occur after ICL implantation. These problems were unresolvable despite four repeated laser iridotomies. The risks associated with anterior uveitis must be considered when planning an ICL implantation.


Asunto(s)
Femenino , Humanos , Persona de Mediana Edad , Iridectomía/métodos , Iris/cirugía , Terapia por Láser , Láseres de Estado Sólido , Implantación de Lentes Intraoculares/efectos adversos , Lentes Intraoculares Fáquicas , Epitelio Pigmentado Ocular/patología , Complicaciones Posoperatorias , Recurrencia , Reoperación , Malla Trabecular/patología , Uveítis Anterior/etiología
11.
Journal of the Korean Ophthalmological Society ; : 465-472, 2007.
Artículo en Coreano | WPRIM | ID: wpr-69914

RESUMEN

PURPOSE: We have investigated the long term effect, stability, predictability and complication of ICL implantation to treat high myopia. METHODS: We investigated retrospectively in 176 eyes of 97 patients with spherical equivalent -11.91D (-6D~-23D) that were followed up for at least 6 months after ICL implantation. RESULTS: Mean spherical equivalent was maintained stable as -0.54D at 1 week post-operatively, and at -0.55D for 5years. There was high effect and predictability, with 92.3% of the eyes exhibiting a greater than or equal to best corrected visual acuity (BCVA), 83% of eyes having a post-operative uncorrected visual acuity (UCVA) of 0.5 or better, 91.3% having a post-operative refraction of -1.0D~+1.0D, and 86.4% having a post-operative refraction of -0.5D~+0.5D. The most common complications were glare and halos. With a temporary increase in IOP, significant endothelial cell loss was observed. Repositioning for a dislocated ICL was done in 3 eyes. Post-operative cataracts were found in 7 eyes (3.9%), which was a significant increase in incidence, but not surprising, as the patients were older and had lower Vaulting values. CONCLUSIONS: ICL implantation to treat high myopia was an effective surgery with good predictability and stability, and effective in both short term and long term follow-up periods.


Asunto(s)
Humanos , Catarata , Células Endoteliales , Estudios de Seguimiento , Deslumbramiento , Incidencia , Miopía , Estudios Retrospectivos , Agudeza Visual
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA