Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 551
Filtrar
1.
Acta Pharmaceutica Sinica ; (12): 643-650, 2024.
Artículo en Chino | WPRIM | ID: wpr-1016629

RESUMEN

Three carboline fluorescent probes F1-F3 were designed and synthesized, based on lead compound JYJ-19, an antifungal compound discovered previously by our group. The antifungal activity in vitro results showed that compound F1 had moderate antifungal activity (MIC80 = 32 μg·mL-1). The stokes shift of F1 is 70 nm. The fluorescent probe F1 has good optical properties and can be used for fluorescence imaging research. Subcellular localization experiments results showed that F1 was enriched in the mitochondria of fungal cells. The detection of intracellular reactive oxygen species levels shows that JYJ-19 enhances intracellular reactive oxygen species levels. The above results indicated that carboline compounds could exert antifungal effects by acting on fungal mitochondria.

2.
Artículo | IMSEAR | ID: sea-219283

RESUMEN

Background:Transesophageal echocardiography (TEE) probe insertion may be associated with many complications. Demographic factors and airway conditions such as high Mallampati scores (MMC) and Cormack-Lehane grades (MCLG) are likely to have an impact on its ease of insertion. The primary aim of this study was to identify the predictive factors for difficult real-time-three-dimensional TEE probe insertion. Methods: A total of 153 adult patients undergoing cardiac surgery were prospectively evaluated. The upper airway manipulations required for TEE probe placement were jaw thrust, reverse Sellick抯 maneuver, and laryngoscopy. All the patients who required airway manipulations were grouped under difficult TEE probe placement group. We evaluated the patients� predictive factors such as demographic characteristics and factors related to difficult intubation. Results: Out of 153 patients, 123 were males and 30 were females. Overall, 27.5% (n = 42) patients had difficulty in probe placement. About 31.7% (n = 39) males had difficulty in TEE probe placement against 13% (n = 4) females (P?value 0.045). Difficulty in TEE probe placement was found in 72.7% (n = 16) of obese patients (body mass index [BMI] > 30), compared to 18.6% (n = 17) in the patients with BMI less than 25 (P-value < 0.001). Probe insertion was significantly more difficult in the presence of MMC III and IV (50%, n = 18) compared to class I (19.2%, n = 10) (P?value 0.001) and MCLG III (73.3%, n = 22) compared to grade I (11.1%, n = 7) (P-value 0.001). Conclusion: Male gender, obesity, higher grades of MMC and MCLG were found to be the risk factors for difficult TEE probe placement in anesthetized patients.

3.
Acta Pharmaceutica Sinica ; (12): 2180-2192, 2023.
Artículo en Chino | WPRIM | ID: wpr-999151

RESUMEN

Cancer seriously threatens human life and health, it is urgent for the development of rapid detection, precise localization and effective treatment of tumors. Chemical fluorescent probes that are sensitive to tumor-specific microenvironments have important significance in tumor theranostics and a variety of such probes have been developed. In this review, we classified chemical fluorescent probes that are sensitive to tumor microenvironments according to biological characteristics and microenvironmental changes while combining spectroscopy or response mechanisms, and systematically introduced the research progress of chemical fluorescent probes with sensitivity to hypoxia, low polarity, high viscosity, abnormal pH values and abundant reactive oxygen species in tumor microenvironments, in order to provide references for the development and applications of these probes.

4.
Acta Pharmaceutica Sinica ; (12): 2250-2259, 2023.
Artículo en Chino | WPRIM | ID: wpr-999146

RESUMEN

Small molecule fluorescent probes have gained widespread attention for their advantages of high selectivity, sensitivity, and easy to operate, and have played a critical role in the detection of various species. They have also demonstrated great potential in the field of biomedical research. Iron, as the most abundant transition metal in the human body, plays a vital role in many physiological functions. Due to the influence of the reductive microenvironment of cell, ferrous ion (Fe2+) is the main component of labile iron in living cells. Heme, consisting of Fe2+ and protoporphyrin IX, is one of the main signaling molecules that wrap biological iron in the human body, and also participates in many physiological and pathological processes. Therefore, the development of small molecule fluorescent probes for detecting Fe2+ and heme as effective monitoring tools will help to further understand their pathological and physiological functions, with potential applications in other fields. This review summarizes the research progress of small molecule fluorescent probes for Fe2+ and heme detection in recent years, and provides insights into future directions for their development.

5.
Acta Pharmaceutica Sinica ; (12): 3400-3407, 2023.
Artículo en Chino | WPRIM | ID: wpr-999101

RESUMEN

In this study, we synthesized six tetrazine-dipyrromethene boron difluoride (BODIPY) probes and achieved a remarkable up to 14-fold increase in singlet oxygen yield via tetrazine bioorthogonal click-to-release reactions. We systematically investigated the photodynamic activity of these probes, revealing crucial structure-activity relationships. Additionally, we evaluated the stability and release kinetics of these probes and identified P5 and P6 as ideal candidates for photodynamic therapy in live cells. This innovative strategy opens new avenues for fine-tuning the photodynamic properties of BODIPY dyes, thereby expanding their utility in cancer therapy.

6.
Acta Pharmaceutica Sinica ; (12): 2727-2733, 2023.
Artículo en Chino | WPRIM | ID: wpr-999031

RESUMEN

italic>α-Conotoxin ArIB[V11L,V16D] is currently the most optimal selective inhibitor of α7 nicotinic acetylcholine receptor (nAChR) known. In order to explore chemical modification methods and enrich its application in targeting nAChR, this study utilized the linker to covalently connect camptothecin and 7-amino-4-methylcoumarin to the [2,4] disulfide bond of ArIB[V11L,V16D]. Therefore, two peptide-drug conjugates (PDCs), ArIB[V11L,V16D]-5 and ArIB[V11L,V16D]-6, and one fluorescent-labeled peptide, ArIB[V11L,V16D]-7 were constructed. Cytotoxicity evaluation showed that the IC50 values against non-small cell lung cancer cell line A549 of the two PDCs were respectively 1.3 and 4.1 times of camptothecin, indicating slight reduction in activity at the cellular level which was related to the linker structure. Fluorescence spectrum scanning revealed that the excitation and emission wavelength of the fluorescent-labeled peptide were 340 nm and 403 nm respectively, and the fluorescence features of 7-amino-4-methylcoumarin as a marker were retained without fluorescence quenching. This modification strategy laid a solid foundation for the further application of α-conotoxin ArIB[V11L,V16D] in PDCs and fluorescent probes.

7.
Malaysian Journal of Medicine and Health Sciences ; : 148-152, 2023.
Artículo en Inglés | WPRIM | ID: wpr-997883

RESUMEN

@#Introduction: The gingival phenotype (GP) of teeth at the aesthetic zone often influences dental rehabilitation plans and treatment outcomes. This study aimed to assess the prevalence of GP in the Malay population in relation to gender and age. Methods: The GP of 100 patients were determined using the Probe test method. Other clinical parameters were assessed include crown width/crown length (CW/CL) ratio, tooth morphology and width of keratinised tissue. Periodontal parameters were assessed by two calibrated examiners. Data were analysed using descriptive statistics, one-way ANOVA and Kruskal-Wallis test. Results: A higher prevalence of thick GP was found at the maxilla for both genders, whereas a thin phenotype was observed at the mandible. At maxilla, both thick and thin GP were found in all age groups, while the mandible showed a higher prevalence of thin GP. Significant differences in GP were found between males and females for mandibular and maxillary anterior teeth and the mandibular lateral incisor (p<0.05), while no significant difference was found for other parameters assessed; age group, CW/CL, tooth morphology and WKT. Conclusion: Thicker GP is more prevalent in male population and at maxillary anterior. Mandibular anterior GP presented commonly with a thin GP regardless of gender or age-group.

8.
Chinese Journal of Biologicals ; (12): 1218-1223, 2023.
Artículo en Chino | WPRIM | ID: wpr-996681

RESUMEN

@#Objective To develop and verify a multiplex fluorescence quantitative PCR(Taqman probe) method for the detection of telomerase activity.Methods Specific reverse transcription primers,two pairs of quantitative primers and probes were designed for the CDS sequence of telomerase catalytic subunit telomerase reverse transcriptase(TERT).After optimization of the reverse transcription primers(specific reverse transcription primers and random primers) and quantitative primers(two pairs of quantitative primer probes used alone or in combination) in the reaction system,with the primer probe of internal reference gene GAPDH,multiplex fluorescence quantitative PCR was performed in a single tube.In addition,telomerase positive standard and negative standard were prepared with 293T and MRC-5 cells respectively,and the stability and precision of the method were verified.The telomerase activity in 19 normal mesenchymal cell samples and 32 breast cancer cell samples were detected by the developed method.Results The optimum reaction system was as follows:using cDNA synthesized with specific reverse transcription primers as the template,2 pairs of quantitative primer probes of TERT gene were mixed with internal reference gene GAPDH primer probes for multiplex fluorescence quantitative PCR reaction in a single tube.After optimization,the sensitivity and TERT fluorescence signal quantity of the system were greatly improved,and the ΔRn was enhanced by 3 times.The amplification curve of positive standard TERT gene was normal,and the ΔCt between TERT gene and GAPDH gene remained stable.The amplification curve of GAPDH gene in negative standard was normal,while there was no amplification curve of TERT gene.There was a little difference in ΔCt between TERT and GAPDH genes in the positive standard frozen and thawed for 3 and 5 times repeatedly and the positive standard without freezing and thawing,and the CVs of precision in intra-and inter-groups were all less than 1%.Telomerase activity was negative in 19 normal mesenchymal cell samples and positive in 32 breast cancer cell samples,and significant difference in Ct value of TERT gene between them was observed(t=4.236,P <0.001).Conclusion The developed multiplex fluorescence quantitative PCR(Taqman probe) method for the detection of telomerase activity has good stability and precision,which is expected to be used in early diagnosis and gene therapy of tumors.

9.
Chinese Journal of Digestive Endoscopy ; (12): 359-364, 2023.
Artículo en Chino | WPRIM | ID: wpr-995391

RESUMEN

Objective:To study reflux characteristics of patients with endoscopic negative heartburn and their manifestation under probe-based confocal laser endoscopy (pCLE) based on the Rome Ⅳ standard.Methods:Thirty-six endoscopic negative outpatients with typical heartburn at the Department of Gastroenterology of the Second Affiliated Hospital of Baotou Medical College from September 2020 to March 2021 were included, and underwent 24-hour multichannel intraluminal impedance-pH monitor and pCLE. According to Rome Ⅳ diagnostic process, patients were divided into non-erosive reflux disease (NERD) group ( n=16), reflux hypersensitivity (RH) group ( n=8) and functional heartburn (FH) group ( n=12). The Gerd-Q scale score, 24-hour pH monitoring results and microstructure changes under pCLE were compared among the three groups. Results:There was no significant difference in the total score, positive symptom score, negative symptom score or positive influence score of Gerd-Q scale among the three groups ( P>0.05). DeMeester score [28.45 (20.08, 34.53)] and acid reflux times (24.88±9.05) in the NERD group were significantly higher than those in the RH group [7.30 (3.90, 11.38), P<0.001; 13.63±5.76, P=0.003] and FH group [6.90 (4.80, 9.73), P<0.001; 7.42±8.32, P<0.001]. But there was no significant difference between the RH group and the FH group ( P>0.05). The diameter of intra-papillary capillary loop (IPCL) (18.68±2.12 μm) and dilation of intercellular space (3.95±0.97 μm) in the NERD group were significantly higher than those in the RH group (13.91±1.99 μm, P<0.001; 2.97±0.55 μm, P=0.006) and FH group (13.83±2.00 μm, P<0.001; 2.31±0.54 μm, P<0.001), but there was no significant difference between the RH group and the FH group ( P>0.05). The number of IPCL in the NERD group, RH group and FH group were 2.0 (1.00, 2.75), 2.0 (1.00, 2.75) and 1.5 (1.00, 2.00), respectively with no significant difference ( P=0.697). Conclusion:Gerd-Q scale is not suitable for differential diagnosis of patients with endoscopic negative heartburn. Compared with functional esophageal diseases (RH and FH), acid reflux and mucosal microstructure changes are of more important pathogenic significance in NERD.

10.
Clinical Medicine of China ; (12): 53-56, 2023.
Artículo en Chino | WPRIM | ID: wpr-992464

RESUMEN

Objective:To investigate the clinical and genetic characteristics of Prader-Willi syndrome (PWS).Methods:The clinical data and genetic characteristics of 2 children with PWS diagnosed in Hebei Provincial People's Hospital were retrospectively analyzed, and the relevant literature was reviewed.Results:Case 1, male, aged 6 years and 3 months, was presented to the hospital because of short stature, mild mental retardation, dysarthria, scoliosis, cryptorchidism, micropenis, long skull, narrow face, almond eyes, small mouth, thin upper lip, downward corners of the mouth, fair skin. He had hypotonia and feeding difficulties in infancy, and gradually became hyperappetitive. Bilateral cryptorchidism surgery was performed at 1.5 years old, but the effect was not good. Case 2, male, aged 4 years, presented to the hospital mainly due to obesity, hyperappetite, excessive weight gain, backward language and cognitive function, dysarthria, and scoliosis.The infant had feeding difficulties in the early stage, and bilateral cryptorchidism surgery at the age of 2 was not effective.Methylation specific polymerase chain reaction and methylation specific multilink probe amplification were used to detect the loss of the parent fragment in the key region (15q11-13) of PWS, which confirmed Prader-Willi syndrome.Conclusion:PWS is a rare hereditary disease with complex and diverse clinical manifestations and different characteristics in different age groups. It is highly susceptible to unexplained hypotonia and feeding difficulties in infancy. Children with short stature and obesity should be alert to the disease, which can be clearly diagnosed by molecular genetic techniques.

11.
Chinese Journal of Behavioral Medicine and Brain Science ; (12): 599-604, 2023.
Artículo en Chino | WPRIM | ID: wpr-992139

RESUMEN

Objective:To explore the effects of embodied emotion priming on attentional bias of individuals with depression tendency.Methods:From June to December 2018, a total of 91 college students with depression tendency were recruited to participate in the experiment.A 3(embodied emotion priming: positive priming, negative priming and no priming) × 2 (emotional face: happy and sad) mixed design was adopted to measure the attentional bias of individuals with depression tendency using the dot probe paradigm. SPSS 22.0 statistical software was used for repeated measurement analysis of variance.Results:In terms of attentional bias, the interaction effect between embodied emotion priming types and emotional faces was significant ( F(2, 88)=5.97, P=0.004, ηp2=0.119). Further simple effect analysis showed that, under the happy-face condition, participants' attentional bias reaction time(△RT) was significantly higher when primed with embodied positive emotion than those primed with embodied negative emotion((14.30±18.23)ms, (-6.53±38.17)ms, P<0.05). The participants' attentional bias △RT was significantly lower when primed with embodied negative emotion than participants with no priming ((-6.53±38.17)ms, (9.16±30.62)ms, P<0.05). Under the sad-face condition, the participants' attentional bias △RT was significantly higher when primed with embodied negative emotion((28.22±35.33)ms) than participants primed with embodied positive emotion((11.71±29.24)ms, P<0.05) and no priming ((7.63±30.60)ms, P<0.05). Conclusion:Embodied emotion priming can affect the attentional bias of individuals with depression tendency.

12.
Journal of Pharmaceutical Analysis ; (6): 216-222, 2023.
Artículo en Chino | WPRIM | ID: wpr-991137

RESUMEN

The direct coupling of solid-phase microextraction(SPME)to mass spectrometry(MS)(SPME-MS)has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as blood and plasma.In recent years,our lab has developed three novel SPME-MS techniques:SPME-microfluidic open interface-MS(SPME-MOI-MS),coated blade spray-MS(CBS-MS),and SPME-probe electrospray ionization-MS(SPME-PESI-MS).The fast and high-throughput nature of these SPME-MS technologies makes them attractive options for point-of-care analysis and anti-doping testing.However,all these three techniques utilize different SPME geometries and were tested with different MS instruments.Lack of comparative data makes it difficult to determine which of these methodologies is the best option for any given application.This work fills this gap by making a comprehensive comparison of these three technologies with different SPME devices including SPME fibers,CBS blades,and SPME-PESI probes and SPME-liquid chromatography-MS(SPME-LC-MS)for the analysis of drugs of abuse using the same MS instrument.Furthermore,for the first time,we developed different desorption chambers for MOI-MS for coupling with SPME fibers,CBS blades,and SPME-PESI probes,thus illustrating the universality of this approach.In total,eight analytical methods were developed,with the experimental data showing that all the SPME-based methods provided good analytical performance with R2 of linearities larger than 0.9925,accuracies between 81%and 118%,and good precision with an RSD%≤13%.

13.
Chinese Journal of Postgraduates of Medicine ; (36): 461-465, 2023.
Artículo en Chino | WPRIM | ID: wpr-991040

RESUMEN

Objective:To analyze the results of the joint screening of newborn hearing and deafness genes in Dalian to provide a reference for the prevention and control of hereditary deafness.Methods:Eight hundred and forty-two neonates born in Dalian Women and Children′s Medical Group from January 1, 2022 to May 30, 2022 were screened retrospectively, using AABR (automatic brainstem evoked potential). And 20 mutation sites of common genetic deafness 4 genes , including GJB2, GJB3, SLC26A4 (PDS) and mitochondrial genes associated with drug-induced deafness (MT-RNRI)(12SrRNA), were detected by high-throughput sequencing.Results:Among the 842 newborns, 840 passed hearing screening (99.8%); 36 cases (4.3%) passed the hearing screening but not the hearing loss gene screening; 804 cases passed through the both screening (95.5%); 2 cases (0.24%) failed in the both screening. 38 cases of deafness gene mutations were detected, with a total carrying rate of 4.51% (38/842). Among them, the carrying rates of heterozygous mutations in GJB2, GJB3, SLC26A4 (PDS), MT-RNRI (12SrRNA) were 1.90%, 0.24%, 1.30%, and 0.95%, respectively. The carrying rates of GJB2/GJB3 composite heterozygous mutations were 0.12%.Conclusions:The combined screening of neonatal hearing and deafness genes can reduce the missed rate of hearing screening. The carrier rate of neonatal deafness gene in Dalian is 4.51%, with the highest GJB 2 carrier rate, followed by SLC26A4 (PDS) carrier rate.

14.
International Journal of Biomedical Engineering ; (6): 185-190, 2023.
Artículo en Chino | WPRIM | ID: wpr-989337

RESUMEN

Objective:To prepare a peptide fluorescent probe based on aggregation-induced emission and to investigate its application in the detection of early caries.Methods:Eight aspartate-serine-serine (DSS) were combined with aggregation-induced emission material to prepare peptide fluorescent probes, and an artificial demineralization model was established in vitro. The samples were immersed in the peptide fluorescent probe solution for 1 min, and a fluorescence imaging system was applied to examine the tooth samples and collect images and fluorescence data. Scanning electron microscopy was also applied to observe the phenotype of the teeth, and electron microscopy was applied to detect the calcium-phosphorus ratio on the enamel surface of the teeth. Polarized light microscopy was also applied to observe the enamel area of the teeth. Results:The fluorescence intensity of demineralized teeth was clearly observed to be lower than that of normal teeth in the peptide fluorescent probe-treated area, and the difference was statistically significant ( P < 0.05). The results of scanning electron microscopy showed that the enamel surface of the demineralized group had more irregular pores, while the enamel surface of the undemineralized group was flatter with only some irregular accumulation of flakes. The results of polarized light microscopy showed that a clear birefringence could be observed in the enamel region of normal teeth, while a black area or the disappearance of the birefringence effect accompanied by a partial black dark shadow could be observed in the enamel region of demineralized teeth. Conclusions:An aggregation-induced luminescence-based peptide fluorescent probe was successfully prepared, which can precisely localize the enamel and show some application value in early caries detection.

15.
Chinese Pharmacological Bulletin ; (12): 1592-1608, 2023.
Artículo en Chino | WPRIM | ID: wpr-1013746

RESUMEN

Aim To rapidly prepare and purify hydrogen sulfide specific fluorescent probe (WSP-5), establish and optimize the fluorescent probe method for the determination of hydrogen sulfide in animal tissues, and verify the applicability of the method in the model of malignant pleural effusion. Methods The preparation solvent of fluorescent probe reaction solution, DMSO addition volume, pH, reaction solution solvent and reaction solution volume, sample pretreatment temperature, grinding times, and standing time after grinding were investigated. The mouses model of malignant pleural effusion was established with S-180 ascites tumor cells, and the concentration of hydrogen sulfide in various organs and tissues of the model animal was measured. Results After optimization, silica gel and dextran gel were used as stationary phases, dichloromethane methanol formic acid (60: 1: 0.1, V/V/V) and dichloromethane methanol (1: 1, V/V) were used as eluents for separation and purification, and the first eluting component was taken to prepare WSP-5 with a purity of more than 700 mg. Animal tissue samples and sodium hydrosulfide standard solution were added with 5 times of cold reaction solution, after low temperature vibration grinding, highspeed centrifugation, the supernatant was incubated in dark for 12 hours, the fluorescence intensity was measured by fluorescent microplate reader. Hydrogen sulfide concentration was calculated according to the standard curve. The LOD of this method was about 0. 6 |JLmol • L

16.
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6): 383-388, 2023.
Artículo en Chino | WPRIM | ID: wpr-1005843

RESUMEN

【Objective】 To screen and verify a peptide ligand specific for CD44v9. 【Methods】 A 12-mer phage peptide library was screened on CD44v9 coated on solid phase. Candidate sequences emerged after sequencing. Candidate phages were selected using enzyme-linked immunosorbent assay. The best sequence was chosen for further study. Binding of C9-3 to CD44v overexpressed HEK-293 cells was determined using immunofluorescence. Binding affinity and specificity were verified on gastric cancer tissues with immunohistochemistry. 【Results】 Phages significantly were enriched during panning process. After sequencing, nine individual sequences occurred in 30 selected clones. Among the 9 candidate sequences, C9-3 exhibited the highest frequency. Results of ELISA showed that C9-3 had the highest OD value and selectivity. Thus, C9-3 was chosen for peptide probe synthesis. C9-3 probe stained CD44v overexpressed HEK-293 cells, but not empty vector transfected HEK-293 cells. Immunohistochemistry scores of C9-3 were significantly different between gastric cancer and paracancer tissues (t=3.953, P<0.01). A linear positive correlation was observed between C9-3 binding and CD44v9 expression (r=0.823, P<0.01). 【Conclusion】 In this study, peptide ligand of CD44v9 was successfully screened. The peptide can bind to cells and cancer tissues via CD44v9. It has potential for gastric targeting probes.

17.
Chinese Journal of Blood Transfusion ; (12): 563-566, 2023.
Artículo en Chino | WPRIM | ID: wpr-1004784

RESUMEN

【Objective】 To study the concordance of identifying the presence or absence of KIR genes using flow reverse sequence-specific oligonucleotide probe (Flow-rSSO) hybridization and sequencing based typing-PCR (PCR-SBT) methods. 【Methods】 A total number of 131 cases of DNA samples from Han population were subjected to identify the presence or absence of all 16 KIR genes by Flow-rSSO method, and then sequenced at coding sequence for all 14 functional KIR genes using our in-house KIR PCR-SBT assay. The concordance of identifying the presence or absence of all functional KIR genes by Flow-rSSO and PCR-SBT was analyzed. Samples with inconsistent initial results were re-tested using the Flow-rSSO commercial kits with different Lot number, and further tested using the PCR-SSP commercial kit. 【Results】 The presence or absence of 14 functional KIR genes for 129 of 131 samples were completely in accordance via the PCR-SBT and Flow-rSSO methods. Two samples, one with 3DL1 negative, the other with both 2DS3 and 2DS5 negative initially-identified by Flow-rSSO, were actually all positive tested by PCR-SBT. Further retest by Flow-rSSO commercial kits with different Lot number and PCR-SSP commercial kit indicated that the two samples were all positive, which agreed well with PCR-SBT results. 【Conclusion】 In this paper, the initial test results of the presence or absence of KIR genes identified by Flow-rSSO for 2 samples were wrong, which indicated the importance of carrying out the quality control for reagents in KIR gene testing.

18.
Journal of China Pharmaceutical University ; (6): 553-563, 2023.
Artículo en Chino | WPRIM | ID: wpr-1003575

RESUMEN

@#Sulfane sulfur species in the reactive sulfur species family include hydrogen polysulfides (H2Sn, n ≥2), which play an essential role in physiological regulation and signal transduction. As a redox pair of H2S, H2Sn can be produced through oxidation or enzyme reaction and regulate protein interaction and enzyme activity.Research has revealed that H2Sn, with higher efficiency of protein S-sulfhydration than H2S, may be responsible for some physiological functions previously attributed to H2S.Therefore, real-time detection of H2Sn is crucial for studying its physiological activity and the relationship between H2S and H2Sn.Traditional detection methods, such as mass spectrometry, are not suitable for living organisms as they require tissue cell disruption.Instead, fluorescence probes are often used for in situ real-time detection due to their high sensitivity and specificity and low biological toxicity.This review summarizes the physiological regulatory activity of H2Sn, as well as the design strategy, response mechanism, fluorescence characteristics, and biological applications of H2Sn fluorescent probes based on the structure of the response group, with a prospect of the challenges and developments in this field.

19.
Rev. Soc. Bras. Med. Trop ; 56: e0238, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1449347

RESUMEN

ABSTRACT Background: We aimed to evaluate the costs of GenoType® MTBDRplus and MTBDRsl incurred during the diagnosis of first- and second-line drug-resistant tuberculosis (TB) in São Paulo, Brazil. Methods: Mean and activity-based costs of GenoType® were calculated in a referral laboratory for TB in Brazil. Results: The mean cost value and activity-based cost of GenoType® MTBDRplus were USD 19.78 and USD 35.80 and those of MTBDRsl were USD 54.25 and USD 41.85, respectively. Conclusions: The cost of GenoType® MTBDRplus was reduced owing to the high number of examinations performed and work optimization.

20.
Ann. afr. méd. (En ligne) ; 16(2): 5099-5103, 2023. figures, tables
Artículo en Francés | AIM | ID: biblio-1425959

RESUMEN

Contexte et objectifs. La sonde double J est très utilisée de nos jours dans le drainage des urines du haut appareil. L'objectif de la présente étude était de décrire le devenir de la pose de la sonde double J. Méthodes. Il s'est agi d'une étude documentaire d'une série des cas ayant bénéficié d'un drainage urinaire du haut appareil par une sonde double J au Centre National Hospitalo-Universitaire Hubert Koutoukou Maga de Cotonou, Bénin ; entre les 1er avril 2018 et 31 mars 2021. Résultats. Les dossiers de cent trois patients (âge moyen 48,4 ans, sexe masculin, 58,3 %) ont été colligés. La pose de la sonde double J représentait 84,74 %. La pose de la sonde double J était unilatérale dans 76,7 % des cas avec une prédominance à droite (56,0 %). L'abord par voie endoscopique pour la pose de la sonde double J était la plus pratiquée (89,3 %). La pose de la sonde double J a été effectuée sans guidage fluoroscopique (à l'aveugle) dans 73,7 % et la durée moyenne du port de cette sonde était 118,37 jours. La fonction rénale était perturbée avec un débit de filtration glomérulaire < 60 ml/minute/1,75 m2 chez 33,0 % des patients. Les étiologies à la base d'une obstruction étaient dominées par la pathologie lithiasique (63,1 %). Le taux de réussite de la sonde double J était de 77,6 %. Les échecs de la sonde double J étaient dus aux pathologies tumorales dans 15,53 %. La durée moyenne d'hospitalisation après la pose de la sonde double J par voie endoscopique était de 7,72 jours. Conclusion. Le syndrome obstructif surtout d'origine lithiasique reste la plus importante indication de l'usage de la sonde double J. Sa réalisation sans guidage fluoroscopique (à l'aveugle) est possible dans le milieu ne disposant pas d'amplificateur de brillance.


Asunto(s)
Humanos , Urología , Andrología , Endoscopía , Enfermería en Nefrología , Antiinfecciosos Urinarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA