Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Pesqui. vet. bras ; 39(8): 587-591, Aug. 2019. tab, ilus
Artículo en Inglés | LILACS, VETINDEX | ID: biblio-1040722

RESUMEN

This paper investigated the occurrence of Staphylococcus aureus and the detection of enterotoxin-encoding genes of these strains in milk collected from 30 Murrah buffaloes used to produce dairy products in Brazil. A total of 68 strains of Staphylococcus aureus were found as identified by conventional laboratory tests, and thus screened for sea, seb, sec, sed, see, seg, seh and sei enterotoxin-encoding genes by polymerase chain reaction (PCR). Twelve strains containing enterotoxin-amplified genes were found, with higher expression for the sei and seh genes. These results can be attributed to animal health and inadequate cleaning of the equipment, indicating the need for better quality control in animal production and health lines. The results of this study with the presence of pathogens and their enterotoxigenic potential indicate a source of food poisoning, as well as being a pioneering study in the detection of new enterotoxins for buffalo milk.(AU)


Este estudo investigou a ocorrência de isolados de Staphylococcus aureus e a detecção de genes que codificam a enterotoxigenicidade dessas cepas em leite de búfala utilizado na produção de laticínios no Brasil. As amostras foram coletados em 30 búfalos da raça Murrah, identificado por testes laboratoriais convencionais, foram identificados um total de 68 cepas de S. aureus e rastreados para os genes que codificam a enterotoxina sea, seb, sec, sed, see, seg, seh and sei por reação em cadeia da polimerase (PCR). Doze cepas contendo genes da enterotoxina foram amplificadas, com maior expressão para os genes sei e seh. Esses resultados podem ser atribuídos à saúde animal e à higiene inadequada do equipamento, indicando a necessidade de melhor controle de qualidade nas linhas de produção e saúde animal. Os resultados desta pesquisa, com a presença de patógenos e seu potencial enterotoxigênico, indicam uma fonte de intoxicação alimentar, além de ser uma pesquisa pioneira na detecção de novas enterotoxinas para o leite de búfala.(AU)


Asunto(s)
Staphylococcus aureus/aislamiento & purificación , Contaminación de Alimentos/análisis , Leche/microbiología , Microbiología de Alimentos , Búfalos/microbiología , Calidad de los Alimentos , Reacción en Cadena de la Polimerasa
2.
Hig. aliment ; 33(288/289): 1835-1839, abr.-maio 2019. tab, ilus
Artículo en Portugués | LILACS, VETINDEX | ID: biblio-1482415

RESUMEN

Esse estudo objetivou avaliar a eficácia da implantação do Programa Alimentos Seguros (PAS Leite Campo) sobre a qualidade do leite produzido em propriedades produtoras associadas a uma Cooperativa no estado do Rio Grande do Sul. Para isso, foram coletados dados das análises de contagem de células somáticas (CCS) e contagem de bactérias totais (CBT) do leite de 59 propriedades através de avaliação do histórico de resultados da empresa, além da coleta de amostras de leite para análise dos parâmetros de CCS e CBT durante as sete semanas de implantação do programa. Os resultados obtidos indicaram diminuição na CCS e CBT durante e após a implantação do Programa, quando comparadas ao início. Conclui-se que a implantação da metodologia do PAS proporcionou resultados significativos na redução dos índices de CCS e CBT e na qualidade do leite.


Asunto(s)
Evaluación de Programas y Proyectos de Salud , Leche/citología , Leche/microbiología , Calidad de los Alimentos , Carga Bacteriana , Recuento de Células
3.
Ciênc. rural (Online) ; 49(7): e20180510, 2019. tab
Artículo en Inglés | LILACS | ID: biblio-1045403

RESUMEN

ABSTRACT: Constant monitoring of milk quality by the processing industries demands the use of methodologies that add agility and low-cost analysis, such as the use of electronic equipment based on infrared or ultrasonic spectroscopy. In the present study, quality of raw milk received by dairy farms from western region of Santa Catarina state, Brazil, was evaluated throughout two methodologies of analysis of chemical composition and compared, being that both equipment used standard procedures for calibration, considering as reference data from the classic analytical methods recommended in Brazilian legislation. Milk samples from 45 producers were analyzed for SCC, TBC and physicochemical analysis, performed at dairy's laboratory and at the official laboratory. Infrared and ultrasound methodologies for chemical composition of fat, protein and lactose were compared and correlated. The comparison of the methods showed that there was no significant difference for the mean values of fat (P=0.06); however, they presented significant difference for protein (P=0.001), higher for IR (3.23 vs. 3.33), and lactose (P<0.0001), higher for US (4.47 vs. 4.83). Correlation was positive and significant for fat (r=0.73, P<0.0001), protein (r=0.47, P=0.001) and lactose (r=0.51, P=0.0003). Considering the minimal composition required, TBC and SCC levels, 95.5%, 84.1% and 64.4% of the milk producers met the current Brazilian legislation, respectively. It was concluded that the methodologies have affected results, which may have been influenced by the correction factor used for equipment calibration, specifically for analyzed samples during the study period.


RESUMO: O monitoramento constante da qualidade do leite por parte das indústrias beneficiadoras demanda o uso de metodologias que agregam agilidade e baixo custo por análise, como a utilização de equipamentos eletrônicos que podem ter como princípio a espectroscopia por infravermelho ou por ultrassom. No presente estudo, avaliou-se a qualidade do leite recebido por um laticínio da região extremo oeste catarinense e comparou-se duas metodologias de análise de composição química desta matéria prima, sendo que ambos os equipamentos utilizaram procedimentos padrões para calibração, considerando como referência os dados oriundos dos métodos analíticos clássicos preconizados na legislação Brasileira. Foram comparadas amostras de leite de 45 produtores para análise físico-química, de CCS e CBT, realizadas no laboratório do laticínio e em laboratório oficial. As metodologias por infravermelho (IR) e ultrassom (US) foram comparadas e correlacionadas para composição química de gordura, proteína e lactose. Os resultados demonstraram que não houve diferença significativa para as médias de gordura (P=0,06), entretanto, apresentaram diferença para proteína (P=0,001), maior para IR (3,23 vs. 3,33), e lactose (P<0,0001), maior para US (4,47 vs. 4,83). A correlação foi positiva e significativa para gordura (r=0,73, P<0,0001), proteína (r=0,47, P=0,001) e lactose (r=0,51, P=0,0003). Os resultados das análises de qualidade, considerando composição, CBT e CCS, atenderam a legislação vigente em 95,5%, 84,1% e 64,4% dos produtores, respectivamente. Concluiu-se que as metodologias afetaram os resultados, e estes podem ter sido influenciados pelo fator de correção, utilizado para calibração, sendo específicos para as amostras analisadas durante o período do estudo.

4.
Arq. bras. med. vet. zootec ; 67(2): 607-612, Mar-Apr/2015. tab, graf
Artículo en Portugués | LILACS, VETINDEX | ID: lil-747045

RESUMEN

Contagens bacterianas de 179 amostras de leite cru refrigerado, provenientes de diferentes bacias leiteiras de Minas Gerais, foram realizadas pelos métodos de citometria de fluxo e contagem padrão em placas. O estudo das associações entre a contagem bacteriana total e as contagens bacterianas dos diferentes grupos de micro-organismos foi realizado pela correlação de Pearson. Houve uma forte correlação positiva e significativa entre os valores de contagem de psicrotróficos (r = 0,67) e mesófilos (r = 0,70), determinados pelo método de referência, e os valores da contagem bacteriana total, determinados pela citometria de fluxo. Foi possível estabelecer uma curva de calibração para o citômetro de fluxo utilizando equações de regressão linear. As equações para a contagem bacteriana obtida por citometria de fluxo em função da contagem de mesófilos e psicrotróficos foram: log (CBI) = 0,701 log mesófilos + 1,9091 e log (CBI) = 0,4703 log psicrotróficos + 3,2784, respectivamente. Não foi possível estabelecer curvas de calibrações para termófilos e termodúricos, pois as correlações obtidas entre as contagens desses micro-organismos e a contagem bacteriana total, determinada por citometria de fluxo, foram fracas (r = 0,30 e 0,27, respectivamente).(AU)


Total Bacterial count was performed in 179 raw milk samples from different dairy farms in Minas Gerais State, Brazil, through flow cytometry and standard plate count, that was regarded as the reference method. There was significant strong correlation between the values of psychrotrophic and mesophilic counts determined by the reference method with the values of bacterial count determined by flow cytometry (r = 0.67 and 0.70, respectively), which allowed to establish linear regression equations for bacterial count to calibrate the flow cytometry and estimate the count of mesophilic (log bacterial individual count (BIC) by flow cytometry = 0.701 log mesophilic + 1.9091) and psychrotrophic (log BIC by flow cytometry = 0.4703 log psychrotrophic + 3.2784) bacteria. It was not possible to establish calibration curves for thermophiles and thermodurics due to the weak to moderate correlation coefficients found among these microorganism counts and total bacterial count determined by flow cytometry (r = 0.30 and 0.27, respectively).(AU)


Asunto(s)
Leche/microbiología , Alimentos Enfriados , Carga Bacteriana/veterinaria , Alimentos Crudos/microbiología , Citometría de Flujo/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA