Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Rev. cuba. med. mil ; 52(2)jun. 2023.
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1559818

RESUMEN

Introducción: Estimar la calidad de cualquier instrumento evaluativo escrito, es requisito esencial no solo en su proceso de construcción, sino también en la obtención de información para la toma correcta de decisiones. Objetivo: Evaluar la calidad del examen parcial de la asignatura Sangre y Sistema Nervioso, disciplina Bases Biológicas de la Estomatología, carrera Estomatología. Métodos: Estudio observacional analítico y transversal, en 27 exámenes correspondientes al examen parcial de la asignatura Sangre y Sistema Nervioso, disciplina Bases Biológicas de la Estomatología, carrera de Estomatología, Universidad de Ciencias Médicas de Santiago de Cuba, curso 2022. Se analizó la correspondencia del fondo de tiempo y la cantidad de ítems explorados en el examen, se calcularon índices de dificultad y de discriminación de incisos y preguntas, coeficiente de discriminación biserial puntual y de consistencia interna. Resultados: Existió correspondencia adecuada entre el fondo de tiempo asignado a los contenidos de las temáticas y la cantidad de ítems explorados en el examen. Predominaron los reactivos con índice de dificultad media y buen poder de discriminación. La consistencia interna de las preguntas y del examen general se evaluó de excelente. Conclusiones: La calidad del examen parcial aplicado en la asignatura Sangre y Sistema Nervioso de la disciplina Bases Biológicas de la Estomatología, carrera de Estomatología, Universidad de Ciencias Médicas de Santiago de Cuba, curso 2022, es adecuada.


Introduction: To estimate the quality of any written evaluative instrument is an essential requirement not only in its construction process, but also in obtaining information for correct decision making. Objective: To evaluate the quality of the partial test from Blood and Nervous System subject in Biological Bases of Dentistry discipline, Dentistry career. Methods: Analytical and cross-sectional observational study, in 27 tests corresponding to the partial test of Blood and Nervous System subject, Biological Bases of Dentistry discipline, Dentistry career, Santiago de Cuba Medical Sciences University, course 2022. The correspondence from the background of time and the number of items explored in the test were analyzed, indices of difficulty and discrimination of items and questions, punctual biserial discrimination coefficient and internal consistency were calculated. Results: There was an adequate correspondence between the amount of time assigned to the contents of the themes and the number of items explored in the test. Items with a medium difficulty index and good discrimination power prevailed. The internal consistency of the questions and general test was evaluated as excellent. Conclusions: The quality of the partial test from Blood and Nervous System subject, Biological Bases of Dentistry discipline, Dentistry career, Santiago de Cuba Medical Sciences University, course 2022, is adequate.

2.
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1450077

RESUMEN

Introducción: Dentro de los grandes desafíos que la formación universitaria en el sector salud enfrenta hoy, está el implementar y validar instrumentos de evaluación efectivos. Objetivo: Evaluar la calidad de la prueba parcial del curso propio Bases morfofuncionales de las principales diátesis hemorrágicas en Estomatología, de la Facultad de Estomatología, Universidad de Ciencias Médicas de Santiago de Cuba, curso 2022. Método: Estudio observacional analítico y transversal, en 30 exámenes correspondientes a la prueba parcial del curso propio Bases morfofuncionales de las principales diátesis hemorrágicas en Estomatología, plan de estudio E, carrera de Estomatología, Facultad de Estomatología, Universidad de Ciencias Médicas de Santiago de Cuba, curso 2022. Se analizó la correspondencia del fondo de tiempo y la cantidad de ítems explorados en el examen, se calcularon índices de dificultad y de discriminación de incisos y preguntas, coeficiente de discriminación biserial puntual y de consistencia interna. Resultados: Existió correspondencia adecuada entre el fondo de tiempo asignado a los contenidos de las temáticas y la cantidad de ítems explorados en el examen. Predominaron los reactivos con índice de dificultad media y buen poder de discriminación. La consistencia interna de las preguntas de modo individual fue excelente, pero la del examen en general fue baja. Conclusiones: La calidad del examen parcial del curso propio Bases morfofuncionales de las principales diátesis hemorrágicas en Estomatología, aplicado en la Facultad de Estomatología, Universidad de Ciencias Médicas de Santiago de Cuba, curso 2022, fue poco adecuada.


Introduction: One of the challenges facing universities of health sciences today is the implementation and validation of effective tools for evaluation. Objective: To evaluate the quality of the partial exams of an in-house course in Morphofunctional bases of the most common hemorrhagic diathesis in Stomatology, Facultad de Estomatología, Universidad de Ciencias Médicas de Santiago de Cuba, course 2022. Method: An analytical and transversal observational study was carried out. For the study, it was selected 30 of the partial exams implemented in the in-house Morphofunctional bases of the most common hemorrhagic diathesis in Stomatology course, type (E) course syllabus, Stomatology career, Facultad de Estomatología, Universidad de Ciencias Médicas de Santiago de Cuba, course 2022. Correspondence between scheduled time and the number of items used in the test was assessed, and also, difficulty index and discrimination index for items and questions, point-biserial item discrimination coefficient and internal consistency coefficient were calculated. Results: There was an adequate correspondence between the time scheduled for the topics and the number of items used in the exam. Items with a moderate difficulty index and high degree of discrimination index predominated. The internal consistency of the individual questions was excellent, but the exam in general was low. Conclusions: The quality of the partial exam of the in-house course Morphofunctional bases of the main hemorrhagic diathesis treated in Stomatology, giving in the Faculty of Stomatology, University of Medical Sciences of Santiago de Cuba, course 2022, was inadequate.


Introdução: Entre os grandes desafios que a educação universitária na área da saúde enfrenta hoje, está a implementação e validação de instrumentos de avaliação eficazes. Objetivo: Avaliar a qualidade do teste parcial do curso Bases morfofuncionais da diátese hemorrágica principal em Estomatologia, da Facultad de Estomatología de la Universidad de Ciencias Médicas de Santiago de Cuba, curso 2022. Método: Estudo observacional analítico e transversal, em 30 exames correspondentes à prova parcial do próprio curso Bases morfofuncionais da diátese hemorrágica principal em Estomatologia, plano de estudos E, carreira de Estomatologia de la Universidad de Ciencias Médicas de Santiago de Cuba, curso 2022. A correspondência do analisou-se o fundo de tempo e o número de itens explorados no exame, calcularam-se índices de dificuldade e discriminação de subseções e questões, coeficiente de discriminação bisserial pontual e consistência interna. Resultados: Houve correspondência adequada entre o tempo destinado aos conteúdos dos temas e o número de itens explorados no exame. Predominaram os itens com índice de dificuldade médio e bom poder de discriminação. A consistência interna das questões individuais foi excelente, mas a do exame como um todo foi baixa. Conclusões: A qualidade do exame parcial das Bases Morfofuncionais da diátese hemorrágica principal do curso de Estomatologia, aplicado na Facultad de Estomatología de la Universidad de Ciencias Médicas de Santiago de Cuba, curso 2022, não foi adequada.

3.
Arch. argent. pediatr ; 120(5): 325-331, oct. 2022. tab, ilus
Artículo en Inglés, Español | LILACS, BINACIS | ID: biblio-1390890

RESUMEN

Introducción. Los inmunoensayos de detección rápida de antígenos (TRA) del SARS-CoV-2, son considerados adecuados para el diagnóstico en el punto de atención. El objetivo fue conocer la concordancia entre la reacción en cadena de la polimerasa en tiempo real con transcriptasa inversa (RT-qPCR, por su sigla en inglés) y los TRA en población pediátrica. Población y métodos. Se reclutaron todos los pacientes entre 1 mes y 17 años 11 meses de edad atendidos en la Unidad Febril de Urgencia de un hospital pediátrico entre el 11 de junio y el 3 de octubre de 2021. Se utilizó el TRA Panbio COVID-19 Ag® (Abbott Diagnostic) y, comométodo de referencia, la RT-qPCR (según el protocolo de los Centros para el Control y la Prevención de Enfermedades). Resultados. Se incluyeron 6491 pacientes. La prevalencia de COVID-19 fue del 2,8 %. El92,1 % de los sujetos presentaron síntomas. La sensibilidad, la especificidad y el índice kappa de concordancia para el TRA fueron del 71,0 %, 99,9 % y 0,813, respectivamente. El índice kappa yla sensibilidad del TRA fueron significativamentemayores en el grupo de 13 a 17 años (0,89 y 82,4 %,respectivamente) cuando se los comparó con los grupos de 0 a 5 y de 6 a 12 años. Esto podría deberse a la menor carga viral observada en los pacientes menores de 12 años. Conclusión. Si bien los TRA permiten acortar el tiempo de obtención de los resultados y mejorar la estrategia de aislamiento de pacientes con COVID-19, la sensibilidad en niños menores de 12 años o asintomáticos no se encontraría dentro de los rangos recomendados, sobre todo enperíodos de baja prevalencia de la enfermedad.


Introduction. Rapid antigen tests (RAgTs) for SARS-CoV-2 are considered adequate for diagnosis at the point of care. Our objective was to establish the agreement between reverse transcription-quantitative polymerase chain reaction (RT-qPCR) and RAgTs in the pediatric population. Population and methods. All patients aged 1 month to 17 years and 11 months seen at the Emergency Fever Unit of a children's hospital between 6-11-2021 and 10-3-2021 were recruited. The Panbio COVID-19 Ag® test (Abbott Diagnostic) was compared to the reference method RT-qPCR (as per the protocol suggested by the United States Centers for Disease Control and Prevention). Results. A total of 6491 patients were included. The prevalence of COVID-19 was 2.8%. Symptoms were observed in 92.1%. Sensitivity, specificity, and the kappa index of agreement for the RAgT were 71.0%, 99.9%, and 0.813, respectively. The kappa index and the RAgT sensitivity were significantly higher in the group aged 13­17 years (0.89 and 82.4%, respectively) compared to the groups aged 0­5 and 6­12 years. This may be due to the lower viral load observed in patients younger than 12 years. Conclusion. Although RAgTs shorten the time to result and improve the isolation strategy for COVID-19 patients, their sensitivity in children younger than 12 years or asymptomatic children is not within the recommended ranges, especially during periods of low disease prevalence.


Asunto(s)
Humanos , Lactante , Preescolar , Niño , Adolescente , COVID-19/diagnóstico , Sensibilidad y Especificidad , Servicio de Urgencia en Hospital , Prueba de COVID-19 , SARS-CoV-2 , Hospitales Pediátricos
4.
Med. lab ; 26(2): 159-175, 2022. tab
Artículo en Español | LILACS | ID: biblio-1393231

RESUMEN

Las mediciones confiables, trazables metrológicamente y comparables proporcionan la base racional para la evaluación de la calidad de un resultado y el fortalecimiento de las redes de laboratorios clínicos, lo cual permite mejorar la calidad de atención y la seguridad del paciente. En este documento se revisan los principios básicos que deben seguirse para garantizar la trazabilidad de las mediciones del laboratorio clínico, las ventajas de utilizar métodos trazables, el impacto de no hacerlo, y se discuten las principales limitaciones para relacionar las mediciones con los estándares de medición de referencia apropiados


Reliable, metrologically traceable, and comparable measurements provide the rationale for evaluating the quality of a result and strengthening clinical laboratory networks, thereby improving quality of care and patient safety. This document reviews the basic principles that must be followed to ensure the traceability of clinical laboratory results, the advantages of using traceable methods, the impact of not doing so, and the main limitations in relating measurements to appropriate reference standards


Asunto(s)
Exactitud de los Datos , Juego de Reactivos para Diagnóstico , Estándares de Referencia , Calibración , Equipos y Suministros , Sistema Internacional de Unidades
5.
Rev. nefrol. diál. traspl ; 41(4): 61-70, dic. 2021. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1377156

RESUMEN

ABSTRACT Background: Steroids are the mainstream drugs of immu- nosuppressive regimen in renal transplantation. They are successfully used on induction, maintenance and rejection treatment. Due to complications caused by steroids, treatments are switched to immunosuppressive agents. Graft dysfunction risk caused by reduced total immunosuppression disturbs clinicians very often. We documented the differences among patients by means of clinical presentation and PRA/DSA levels between patients who are using steroids and patients that were prescribed for steroid-free regimen. Methods: 82 individuals who did not use steroid and 52 patients on steroid treatment were included with similar rates of age, sex, primary renal disease, dialysis type, posttransplant follow-up duration and donor type. Pre and posttransplant PRA, DSA levels, posttransplant and current graft function and comorbidities were evaluated. Results: Individuals who do not use steroids were found to have a lower posttransplant creatinine level and glomerular filtration rate (GFR) compared to steroid users. Posttransplant and current spot urinary protein/creatinine rates were also lower in the steroid-free group. However DM, BKVN and induction therapy rates were higher in the steroid-free group. PRA and DSA levels were similar in both groups. On the other hand, posttransplant PRA-I levels were significantly higher in those with less steroid use time. Conclusions: Although steroid free regimens usually worry the clinicians, they can be preferred in patients with low immunological risk for rejection to avoid its side effects such as uncontrolled diabetes, obesity, musculoskeletal problems and cataracts.


RESUMEN Antecedentes: Los esteroides son los principales fármacos del régimen inmunosupresor en el trasplante renal. Se utilizan con éxito en tratamientos de inducción, mantenimiento y rechazo. Debido a las complicaciones causadas por los esteroides, los tratamientos se cambian a agentes inmunosupresores. El riesgo de disfunción del injerto causado por la reducción de la inmunosupresión total perturba a los médicos con mucha frecuencia. Documentamos la diferencia entre los pacientes por medio de la presentación clínica y los niveles de PRA/DSA en aquellos que utilizan esteroides y a los que se les prescribió un regimen sin esteroides. Material y métodos: Se incluyeron 82 individuos que no usaban esteroides y 52 pacientes en tratamiento con esteroides con tasas similares de edad, sexo, enfermedad renal primaria, tipo de diálisis, duración del seguimiento postrasplante y tipo de donante. Se evaluaron la ARP pre y postrasplante, los niveles de DSA, la función y comorbilidades postrasplante y actual del injerto. Resultados: Se encontró que las personas que no usan esteroides tienen un nivel de creatinina postrasplante y una tasa de filtración glomerular (TFG) más bajas en comparación con los usuarios de esteroides. Las tasas de proteína/creatinina urinarias postrasplante y puntuales actuales también fueron más bajas en el grupo sin esteroides. Sin embargo, las tasas de DM, BKVN y terapia de inducción fueron más altas en el grupo sin esteroides. Los niveles de PRA y DSA fueron similares en ambos grupos. Por otro lado, los niveles de PRA-I postrasplante fueron significativamente más altos en aquellos con menos tiempo de uso de esteroides. Conclusiones: Aunque los regimenes libres de esteroides suelen preocupar a los clínicos, pueden ser preferidos en pacientes con bajo riesgo inmunológico de rechazo para evitar sus efectos secundarios, como diabetes no controlada, obesidad, problemas musculoesqueléticos y cataratas.

6.
Rev. méd. hered ; 32(4)jul. 2021.
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1508763

RESUMEN

Objetivo : Evaluar la relación entre el índice urémico (IU) y la función renal medida por el aclaramiento de creatinina (ClCr) en personas sanas y en pacientes con enfermedad renal crónica (ERC); asimismo, comparar con la función renal extrapolada según la creatinina sérica y la calculada por algunas fórmulas recomendadas en la literatura internacional. Material y métodos : Estudio transversal, de correlación, analítico y observacional. Se incluyeron pacientes atendidos de forma ambulatoria en el Hospital Cayetano Heredia, Lima, Perú entre junio del 2018 y junio del 2019. Se realizó correlación de Pearson entre el IU y el ClCr; para la comparación de las medias del IU, creatinina sérica y las fórmulas estandarizadas en función al ClCr estratificado se utilizó el test de ANOVA y el eta cuadrado. Resultados: El IU de la población fue 4,37 ± 4,99 mg/dl y presentó correlación lineal cuadrática estadísticamente significativa con el ClCr (r=-0,74, p=0,000). Asimismo, el IU y el Log IU mostraron un valor predictivo el ClCr superior a la creatinina sérica y a las diversas fórmulas recomendadas en la literatura. El IU presentó correlación significativa con el potasio sérico y su fracción excretoria de forma relevante en comparación con la creatinina sérica. Conclusiones: El IU es un indicador del estado metabólico y nutricional que refleja el ClCr con una precisión estadísticamente significativa en la persona sana y en el paciente con distintos grados de ERC. Además, traduce aspectos relevantes de la función tubular renal.


SUMMARY Objective : To evaluate the relationship between uremic index (UI) and renal function measured by creatinine clearance (CrCl) in persons with normal renal function and in those with chronic renal failure (CRF), as well as to compare the renal function extrapolated from serum creatinine and that calculated with equations internationally recommended. Methods : A cross sectional study was conducted including patients attended in outpatient clinics at Hospital Cayetano Heredia in Lima from June 2018 to June 2019. Pearson's correlation between UI and CrCl was calculated; comparison of means of UI, serum creatinine and standard equations was done by ANOVA and eta square. Results: the overall UI was 4.37 ± 4.99 mg/dl and correlated linearly with CrCl (r=-0.74, p=0.000). The UI and the log UI were significantly more predictive of CrCl than serum creatinine and the international equations used. The UI correlated significantly with serum potassium than serum creatinine. Conclusions : The UI is a good indicator of the metabolic and nutritional status in persons With normal renal function and with CRF and reflects more accurately the CrCl.

7.
Medisur ; 19(2): 318-322, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1279450

RESUMEN

RESUMEN Fundamento La pandemia actual por SARS-CoV-2 contabiliza más de un millón de contagios, y ha causado la muerte, hasta ahora, a más de 300 000 personas. Además, ha tenido un gran impacto psicológico en el contexto latinoamericano. Objetivo describir las características dinámicas de la salud mental en adultos peruanos durante la cuarentena por COVID-19. Métodos estudio descriptivo, que exploró las características dinámicas de manera gráfica, mediante un instrumento de salud mental aplicado (online) a 763 adultos peruanos. Se aplicó un análisis de red mediante los paquetes qgrap y el gráfico LASSO. Resultados se observaron mayores medidas de centralidad de red en los reactivos vinculados a síntomas negativos en la salud mental, como el reactivo 9 (sentimiento de infelicidad y depresión) y el 10 (pérdida de confianza); así como la mayor conexión positiva entre los reactivos 3 (toma de decisiones y confianza) y 4 (sentido de vida); y la mayor relación negativa entre los componentes 1 (concentración) y 5 (tensión y angustia). Conclusión los sujetos participantes en el estudio manifestaron fundamentalmente sentimientos de infelicidad, depresión y pérdida de confianza, entre otros síntomas negativos. El estudio de la repercusión de la pandemia COVID-19 en la salud mental, adquiere mayor precisión y fundamento científico al aplicarse métodos como el análisis de redes.


ABSTRACT Background The current SARS-CoV-2 pandemic accounts for more than one million infections, and has caused the death, so far, more than 300,000 people. In addition, it has had a great psychological impact in the Latin American context. Objective to describe the dynamic characteristics of mental health in Peruvian adults during the COVID-19 quarantine. Methods descriptive study, which explored the dynamic characteristics graphically, using a mental health instrument applied (online) to 763 Peruvian adults. A network analysis was applied using the qgrap packages and the LASSO graph. Results higher network centrality measures were observed in the items related to negative symptoms in mental health, such as item 9 (feeling of unhappiness and depression) and item 10 (loss of confidence); as well as the greater positive connection between items 3 (decision making and trust) and 4 (meaning of life); and the highest negative relationship between components 1 (concentration) and 5 (tension and anguish). Conclusion the individuals participating in the study mainly manifested feelings of unhappiness, depression and loss of confidence, among other negative symptoms. The study of the impact of the COVID-19 pandemic on mental health acquires greater precision and scientific basis when applying methods such as network analysis.

8.
Rev. Bras. Med. Fam. Comunidade (Online) ; 15(42): 2360-2360, 20200210. graf
Artículo en Portugués | ColecionaSUS, LILACS | ID: biblio-1117121

RESUMEN

Objetivos: O objetivo principal foi analisar os indicadores de acesso da unidade de saúde (US) Sesc, antes e após a implantação do acesso avançado (AA). Como objetivo secundário, foram analisados os indicadores de desempenho da US Sesc, antes e após o AA. Métodos: Estudo transversal descritivo com análise dos dados obtidos mensalmente do sistema de informação em saúde do Grupo Hospitalar Conceição, comparando o período de novembro/16 -outubro/17 com novembro/17 - outubro/18. Resultados: Após o AA, o número de atendimentos médicos aumentou 8%, o absenteísmo nas consultas diminuiu de 6,9% para 3% e o número de pacientes diferentes atendidos teve um acréscimo de quase 5%. Em relação ao controle de doenças crônicas, o número de hipertensos atendidos cresceu e também houve um aumento na porcentagem de hipertensos controlados, passando de 74% para 77%. O número de diabéticos atendidos aumentou, assim como a porcentagem de diabéticos controlados subiu de 73% para 81%. Houve uma diminuição de quase 10% de atendimentos a pacientes vinculados à US nos serviços de atenção secundária de referência. Discussão: É possível considerar que a implantação do AA na US Sesc foi associada a uma melhoria dos indicadores de acesso, bem como da maior parte dos indicadores de desempenho analisados.


Objectives: The main objective was to analyze the access indicators of the Sesc health unit (HU), before and after the implementation of advanced access (AA). As a secondary objective, the performance indicators of the health unit Sesc HU were analyzed, before and after AA. Methods:Cross-sectional descriptive study with analysis of data obtained monthly from the health information system of Grupo Hospitalar Conceição, comparing the period of November/16 - October/17 with November/17 - October/18. Results: After AA, the number of medical appointments increased by 8%, absenteeism in consultations decreased from 6.9% to 3% and the number of different patients treated increased by almost 5%. Regarding the control of chronic diseases, the number of hypertensive patients seen increased and there was also an increase in the percentage of controlled hypertensive patients, from 74% to 77%. The number of diabetics treated increased, as did the percentage of controlled diabetics increased from 73% to 81%. There was a decrease of almost 10% in attendance to patients linked to the US in the reference secondary care services. Discussion: It is possible to consider that the implantation of AA in Sesc HU was associated with an improvement in access indicators, as well as most of the performance indicators analyzed.


Objetivos: El objetivo principal era analizar los indicadores de acceso de la unidad de salud (US) Sesc, antes y después de la implementación del acceso avanzado (AA). Como objetivo secundario, se analizaron los indicadores de rendimiento de la US Sesc, antes y después del AA. Método: Estudio descriptivo transversal con análisis de datos obtenidos mensualmente del sistema de información de salud del Grupo Hospitalar Conceição, comparando el período Noviembre/16 - Octubre/17 con Noviembre/17 - Octubre/18. Resultados: Después del AA, el número de citas médicas aumentó en un 8%, el absentismo en las consultas disminuyó del 6,9% al 3% y el número de pacientes diferentes tratados aumentó en casi 5%. Con respecto al control de enfermedades crónicas, el número de pacientes hipertensos vistos aumentó y también hubo un aumento en el porcentaje de pacientes hipertensos controlados, del 74% al 77%. El número de diabéticos tratados aumentó, al igual que el porcentaje de diabéticos controlados aumentó del 73% al 81%. Hubo una disminución de casi 10% en la asistencia a pacientes vinculados a la US en los servicios de atención secundaria de referencia. Discusión: Es posible considerar que la implantación del AA en la US Sesc se asoció con una mejora en los indicadores de acceso, así como en la mayoría de los indicadores de desempeño analizados.


Asunto(s)
Humanos , Femenino , Adulto , Persona de Mediana Edad , Centros de Salud , Indicadores de Calidad de la Atención de Salud
9.
rev. udca actual. divulg. cient ; 20(2): 329-339, jul.-dic. 2017. ilus, tab
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1094682

RESUMEN

El contenido de silicio disponible, generalmente, se ha determinado en suelos ácidos, lo que ha descuidado su cuantificación en otros suelos, para poder realizar recomendaciones de este elemento, acorde a su contenido para cada suelo. El objetivo fue evaluar el silicio disponible por diferentes extractores químicos en suelos del departamento de Córdoba, en Colombia. Para ello, se colectaron, a la profundidad de 20cm, muestras de suelos ácidos, neutros y alcalinos, que fueron ingresados al laboratorio de Suelos y Aguas de la Universidad de Córdoba, para determinar el contenido de silicio disponible. Los extractores químicos fueron cloruro de calcio 0,01mol L-1, ácido acético 0,5mol L-1, acetato de amonio 38,5g L-1, tampón pH 4,0 (HC2H3O2+CH3COONa) y el método propuesto por los autores, denominado solución de cloruro de bario. Para la extracción, se pesaron 5g de suelo y se le adicionó 50mL de solución extractante y la mezcla fue agitada durante 1h, a 220rpm, filtrada y dejada en reposo por 12h. La cuantificación, se realizó en un espectrofotómetro, a una longitud de onda de 66nm y la determinación química, se efectuó en serie, con tres repeticiones, las cuales, fueron analizadas por correlación y contrastes. En general, de acuerdo a los resultados de mayor a menor concentración de silicio, se presentó en la siguiente secuencia de extracción, suelos alcalinos > neutros > ácidos. Mediante las pruebas estadísticas de Tukey y contrastes, se concluyó que el método solución de cloruro de bario se puede utilizar como alternativo al método de referencia en la determinación de silicio en los tres tipos de suelos. Además, para suelos alcalinos, se puede emplear el método de acetato de amonio 38,5g L-1, como alternativa para la determinación de silicio.


The available silicon content has generally been determined in acid soils, but neglected its quantification in other soils, to be able to make recommendations of this element according to its content for each soil. The objective of this research was to evaluate the available silicon in soils of the department of Córdoba, Colombia by means of different chemical extractors. Samples of acid, neutral and alkaline soils were collected at the depth of 20cm and sent to the Laboratory of Soils and Waters of the University of Córdoba to determine the available silicon content. The chemical extractors were 0.01mol L-1 calcium chloride, 0.5mol L-1 acetic acid, 38.5g L-1 ammonium acetate, pH 4.0 buffer (HC2H3O2 + CH3COONa) and the method proposed by the authors, named barium chloride solution. For extraction, 5g of soil were weighed and 50mL of extractant was added and the mixture was stirred for 1h at 220rpm, filtered and left standing for 12h. The quantification was performed in a spectrophotometer at a wavelength of 66nm and the chemical determination was performed in series with three replicates, analyzed by correlation and contrasts. In general, according to results of higher to lower concentration, silicon was presented in the following sequence of extraction, alkaline soils> neutral> acids. By means of the Tukey test and contrasts it was concluded that the barium chloride solution could be used as alternative to the reference method in the determination of silicon in the three types of soils. In addition, for alkaline soils, the ammonium acetate method 38.5g L-1 can also be used as an alternative for the determination of silicon.

10.
INSPILIP ; 1(1): 1-21, ene.-jun 2017.
Artículo en Español | LILACS | ID: biblio-987828

RESUMEN

Objetivo: Determinar la seroprevalencia de la enfermedad de Chagas del cantón Aguarico, provincia de Orellana. Selva amazónica ecuatoriana (2008-2015). Introducción: En el cantón Aguarico los primeros estudios investigativos sobre esta patología comprenden desde 1990 con 1.011 examinados y 61 positivos (3,40 %), 2003 con 6.866 examinados y 76 reactivos (2,40%), 2009 con una población de 2.083 pacientes con 73 reactivos, (3,60 %) y 2008-2015 con 2.235 examinados y 76 positivos (3,40 %) (presente investigación). Material y métodos: Se procesaron las muestras con la técnica Chagatest/Elisa recombinante v.3.0 para determinar positividad a la enfermedad de Chagas. Los casos positivos fueron reconfirmados por el INSPI, Instituto Nacional de Salud Pública e Investigación, con pruebas de hemoaglutinación indirecta (HAI) y Elisa. Con una absorbancia mayor a 1.300. Resultados: La seroprevalencia en las comunidades los porcentajes oscilaron entre (1,32 %) y (13,16 %). Con mayor frecuencia en el sexo femenino (60,53 %). El Riesgo Relativo (RR) de 1,17. El Odds Ratio (OR) 1,18. Siendo mayor el riesgo a desarrollar la enfermedad en los expuestos que en los no expuestos. Conclusiones: Los datos obtenidos confirman la presencia de un foco autóctono de la enfermedad de Chagas en la selva amazónica ecuatoriana. No se detectaron cuadros clínicos agudos ni patologías crónicas, al momento del estudio sin alteraciones radiológicas y con resultados de electrocardiogramas normales; se concluye que la presente investigación, los casos reactivos corresponderían a enfermedad de Chagas en fase indeterminada.


Objective: To determine the seroprevalence of Chagas disease in canton Aguarico Ecuadorian, Province of Orellana. Amazon Forest (2008-2015).Background: The first research studies on this pathology did in Canton Aguarico since 1990, have included 1.011 examined 61 positives (3,40 %), 2003 2.003 with 6866 examined and 76 reactive (2,40 %), 2009 with a population of 2.083 73 reagents, 3,60 %) and 2008-2015 with 2.235 examined and 76 positives (3,40 %) (Present research). Material and methods: the samples were processed using recombinant CHAGATEST / ELISA technique v.3.0 to determine the positivity to Chagas' disease. The National Institute of Public Health and Research (INSPI) reconfirmed positive cases with indirect hemagglutination (HAI) and ELISA tests. With an absorbance greater than 1300. Results: The sero-prevalence in the communities with percentages ranged from 1 (1,32 %) to 10 (13,16 %), often the greater frequency in females. 46 (60,53 %). The Relative Risk (RR) of 1.17. The Odds Ratio (OR) 1.18, being greater the risk to develop the disease in the exposed than in the unexposed ones. Conclusions: The data obtained confirm the presence of an indigenous provenance of Chagas' disease in the Ecuadorian Amazon Forest. There were not detected any acute clinical cases or chronic pathology at the time of the study, withoutradiological alterations and normal electrocardiogram; It is concluded that the present investigation, the reactive cases would correspond to Chagas disease in Indeterminate phase.


Asunto(s)
Humanos , Estudios Seroepidemiológicos , Enfermedad de Chagas , Electrocardiografía , Patología , Investigación , Razón de Masculinidad , Ecosistema Amazónico
11.
Rev. panam. salud pública ; 41: e62, 2017. tab
Artículo en Inglés | LILACS | ID: biblio-1043200

RESUMEN

ABSTRACT The emergence of chikungunya virus in the Americas means the affected population is at risk of developing severe, chronic, rheumatologic disease, even months after acute infection. Accurate diagnostic methods for past infections are essential for differential diagnosis and consequence management. This study evaluated three commercially-available chikungunya Immunoglobulin G immunoassays by comparing them to an in-house Enzyme-Linked ImmunoSorbent Assay conducted by the Centers for Disease Control and Prevention (Atlanta, Georgia, United States). Results showed sensitivity and specificity values ranging from 92.8% - 100% and 81.8% - 90.9%, respectively, with a significant number of false-positives ranging from 12.5% - 22%. These findings demonstrate the importance of evaluating commercial kits, especially regarding emerging infectious diseases whose medium and long-term impact on the population is unclear.(AU)


RESUMEN Como consecuencia de la aparición del virus del chikungunya en las Américas, la población afectada corre el riesgo de padecer reumatismos crónicos graves, aun meses después de la infección aguda. Es fundamental contar con métodos precisos para diagnosticar los antecedentes de la infección a fin de elaborar un diagnóstico diferencial y abordar las manifestaciones de la fase crónica. Se han estudiado tres inmunoensayos comercializados de detección de inmunoglobulinas G para el diagnóstico del chikungunya, comparándolos con el enzimoinmunoanálisis de adsorción (ELISA) propio. Los resultados señalan valores de sensibilidad del 92,8% al 100% y de especificidad del 81,8% al 90,9%, así como un número significativo de falsos positivos, de entre el 12,5% y el 22%.(AU)


Asunto(s)
Humanos , Juego de Reactivos para Diagnóstico , Inmunoglobulina G , Virus Chikungunya/aislamiento & purificación , Inmunoensayo de Polarización Fluorescente , Técnicas para Inmunoenzimas , Fiebre Chikungunya/diagnóstico , Américas , Región del Caribe
12.
Med. lab ; 23(9/10): 459-474, sept-oct. 2017. tab
Artículo en Español | LILACS | ID: biblio-883832

RESUMEN

Resumen: el laboratorio de microbiología es un sistema complejo que implica muchos pasos para cada actividad, requiere de diversas personas y cuyos resultados analíticos generados deben ser lo más exactos posible. De no ser así, las consecuencias se pueden volver muy significativas, entre ellas, la realización de procedimientos innecesarios al paciente, los retrasos en la obtención de un resultado correcto y la ejecución de pruebas diagnósticas adicionales que se podían evitar. Estas consecuencias incrementan los gastos, tanto en términos económicos como en tiempo y esfuerzos del personal. La mayoría de las técnicas analíticas implican diversos procedimientos que están sujetos a cierto grado de imprecisión y posibilidad de error. Por tal razón, es importante la realización de un control de calidad interno que asegure que los productos finales o valores analíticos, que son producidos por un laboratorio, sean lo suficientemente fiables y adecuados para la finalidad que persiguen. De esta manera, un laboratorio microbiológico debe evaluar y documentar el desempeño de todos los aspectos de sus procedimientos, que incluye la calidad de la muestra, la eficiencia de los reactivos y antisueros, las coloraciones, los medios de cultivo, el funcionamiento de instrumentos o equipos, las cepas de referencia y la verificación o validación de los resultados obtenidos. El objetivo de este manuscrito es presentar una revisión bibliográfica sobre algunos elementos del laboratorio de microbiología susceptibles de control de calidad interno, como parte integral del trabajo diario del personal que labora en este. (AU)


Abstract: The microbiology laboratory is a complex system, which involves many steps for each activity and different people, and where analytical results must be as accurate as possible. If the results are inaccurate, the consequences can be significant, including the performance of unnecessary procedures, delays in obtaining a proper result and implementation additional diagnostic tests that could be avoided. These consequences increase spending both economics terms as time and efforts of the staff. Most analytical techniques involve several procedures that are subject to some degree of imprecision and possibility of error. Therefore, it's important to apply an internal quality control that ensure that finished products or analytical values which are produced by a laboratory are sufficiently reliable and appropriate to the objective pursued. In this way, a microbiological laboratory must assess and document the performance of all aspects of its procedures that includes the quality of the sample, the efficiency of reagents and antisera, the staining, the culture media, the operation of instruments or equipment, the strains of reference, and the verification or validation of the results obtained. The aim of this manuscript is to present a literature review about some elements of microbiology laboratory that are susceptible of internal quality control, as an integral part of the daily work of the staff working in this one. (AU)


Asunto(s)
Humanos , Vulnerabilidad Sexual
13.
An. Fac. Med. (Perú) ; 77(4): 409-415, 2016.
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1038231

RESUMEN

Se indagó sobre los desórdenes de la salud mental de los inmigrantes chinos (culíes) que llegaron al Perú en el siglo XIX, entre 1849 y 1874, para suplir la carencia de mano de obra después de la abolición de la esclavitud. Se revisó las publicaciones históricas sobre las condiciones de vida de esa población; los datos se sustentan en registros provenientes de sus centros de trabajo. Los informes, que abarcan el período entre 1865 y 1900, permitieron delinear alteraciones emocionales y de conducta relacionadas con estrés prolongado (reclutamiento traumático, larga e insalubre travesía marítima, sin familia, con trabajo en condiciones de semiesclavitud y encierro en galpones). Se colige la presencia de estados asteniformes somatógenos, depresivos, hipocondríacos o de simulación en los trabajadores calificados como 'mañosos'. La literatura refiere prácticas homosexuales en el encierro obligado de varones solteros y enfermedades de transmisión sexual que incluye a la sífilis; un elevado consumo de opio que trató de ser reemplazado por alcohol y coca; actitudes de desesperanza, resistencia y rebeldía que condujeron a suicidios y homicidios así como a rebeliones grupales y a colaboracionismo durante la Guerra del Pacífico. Estos hallazgos históricos, confrontados con las estadísticas hospitalarias del Manicomio del Cercado (primera parte), coinciden en señalar el alto consumo de opio, por los cuadros diagnosticados en el hospital psiquiátrico como 'locura tóxica' asociada a ese estupefaciente. Hay una discrepancia entre los informes históricos de frecuentes enfermedades de transmisión sexual, incluyendo sífilis, y la escasa prevalencia hospitalaria de parálisis general progresiva (PGP), la forma psiquiátrica de la neurosífilis revelada en la primera parte de este estudio. En la discusión de esta incongruencia se plantea la posibilidad de una malarioterapia ecológica como factor influyente en la baja prevalencia hospitalaria de PGP.


This part inquires the presence of mental health disorders in Chinese immigrants (coolies) who ca me to Peru between 1849 and 1874 as indentured laborers to supply the lack of manpower after the abolition of slavery. Historical publications about how this population lived were reviewed. The main reports were based on historical records from labor places between 1865 and 1900 and let us outline emotional and conduct disorders related to sustained stress (traumatic draft, long and unhealthy sea voyage, life without family, enslaved work and confinement in slave quarters). It is inferred the presence of asthenic states due to somatic diseases, depression, hypochondriasis or simulation in workers called 'mañosos' (tricky). Literature refers homosexual practices in this male population in compulsory confinement and sexually transmitted diseases including syphilis; a great consume of opium, not replaced by alcohol or coca; hopelessness; resistance and revolt attitudes; suicides; homicides; group revolts and collaborationism during the Pacific War. These historical findings confronted with hospital statistics of the Manicomio del Cercado (part 1) coincidently point out high opium consume, diagnosed in the hospital as 'toxic psychosis' associated with this narcotic. There is a discrepancy between historical reports of frequent sexually transmitted diseases, including syphilis and the low hospital prevalence of general paresis, the psychiatric form of neurosyphilis. This incongruence is discussed and the possibility of an ecological malariotherapy as an influencing factor on the low hospital prevalence of general paresis is proposed.

14.
Medisan ; 14(6): 799-806, 20-jul.28-ago. 2010.
Artículo en Español | LILACS | ID: lil-585245

RESUMEN

Se llevó a cabo un ensayo clínico para evaluar el riesgo químico en el laboratorio de análisis del Centro de Estudios de Biotecnología Industrial de la Facultad de Ciencias Naturales de la Universidad de Oriente, con vista a lo cual se identificaron, entre otros aspectos, las características generales del local y de las 20 técnicas establecidas para el análisis de aguas residuales y residuales agroindustriales (11 de estas se aplican 200 veces al año como promedio), frecuencia de los análisis, reactivos químicos empleados y su categoría de peligro (fundamentalmente ácidos minerales, álcalis, solventes orgánicos y oxidantes fuertes), así como se evaluaron los riesgos químico-físicos y las medidas laborales de seguridad, incluido el tratamiento de los residuos antes de ser eliminados. Se observó que los analistas están expuestos a fuentes de calor y vapores de solventes y ácidos a través de la piel y el sistema respiratorio, pero en un trienio solo se produjeron 3 accidentes leves y no hubo certificados médicos por enfermedades ocupacionales en este tipo de instalación


A clinical trial to evaluate the chemical risk was carried out at the analysis laboratory of the Industrial Biotechnology Studies Center in the Natural Sciences Faculty at Oriente University. For this purpose, aspects such as the general characteristics of the site and of the 20 established techniques for the analysis of waste waters and agroindustrial residual were identified, (11 of these were applied 200 times a year as average), frequency of the analyses, chemical reagents used and their danger category (fundamentally mineral acids, alkalis, organic solvents and strong oxidizers), as well as the chemical-physical risks and the security working measures were evaluated, including the treatment of residuals before being eliminated. It was observed that the analysts are exposed to sources of heat and steam of solvents and acids through the skin and the respiratory system, but just 3 mild accidents took place in a triennium, and there were no medical certifications due to occupational diseases in this type of facility


Asunto(s)
Humanos , Adolescente , Persona de Mediana Edad , Biotecnología , Contaminación Química , Residuos Industriales , Laboratorios , Químicos de Laboratorio , Residuos de Laboratorios , Riesgos Laborales
15.
Rev. cuba. estomatol ; 46(3)jul.-sept. 2009.
Artículo en Español | LILACS, CUMED | ID: lil-575679

RESUMEN

Propósito: Presentar 3 casos de fascitisnodular de región facial. Método: Se realizó un estudio de los pacientes que comprendió examen físico, anàlisis de laboratorio y radiológico. Se describió la conducta quirúrgica o médica realizada en cada caso y su diagnóstico anatomopatológico. Resultados: Se mostró el método científico como única vía de llegar al diagnóstico certero, a pesar de enfrentar el reto de diagnosticar una entidad nosológica inusual en la cirugía maxilofacial. Se discutió la evolución de cada paciente y la literatura consultada. Conclusiones: Resulta muy útil la presentación de estos casos, pues esta tumoración presenta una localización muy poco frecuente en cara y su rápido crecimiento y evolución clínica son habitualmente difíciles de interpretar(AU)


Aim: To present 3 cases of nodular fasciitis in facial area. Method: A study was carried out in patients including physical examination, laboratory and radiologic analysis. Surgical or medical behavior was described present in each case with an anatomical and the pathological diagnosis was made. Results: Scientific method was the only route to achieve an accurate diagnosis despite the challenge of diagnosing an uncommon disease entity in maxillofacial surgery. In each patient the course was discussed as well as a literature review. Conclusions: The presentation of these cases is very essential since this tumor has a not much location in the face and its fast developmental and clinical course are often difficult to interpret(AU)


Asunto(s)
Humanos , Femenino , Preescolar , Fascitis/cirugía , Fascitis/diagnóstico por imagen , Fibroma/diagnóstico por imagen , Literatura de Revisión como Asunto , Bases de Datos Bibliográficas
16.
Enferm. univ ; 5(2): 27-31, Abr.-jun. 2008. ilus, graf
Artículo en Español | LILACS, BDENF | ID: biblio-1028480

RESUMEN

El Examen General por Áreas de Conocimiento (EPAC) es una opción de titulación que ofrece la Escuela Nacional de Enfermería y Obstetricia de la UNAM a estudiantes de los sistemas escolarizado; abierto e incorporado; para obtener el grado de licenciatura o profesional técnico en Enfermería. El propósito del artículo es socializar y evidenciar el trabajo realizado con el EPAC de nivel licenciatura a partir de la creación de la Unidad de Apoyo para la Evaluación de los Aprendizajes. Ello ha permitido; con el trabajo de un equipo multidisciplinar; mejorar el proceso del examen; hacer innovaciones informáticas y administrativas; mantener un apoyo educativo directo y confiable tanto a instituciones participantes como a sustentantes. Los resultados que se muestran fueron extraídos de las cuatro aplicaciones realizadas hasta el año 2006; las que se juzgaron a partir de estudios de tipo descriptivo y transversal; con muestra censal. Es innegable que el trabajo permanente con este proceso reorientará las acciones para una mejora continua; que posibiliten altos estándares de confiabilidad lo que garantizará la obtención de resultados más objetivos y oportunos.


The General Test by Knowledge Areas (EPAC) is an option for obtaining the nurse licentiate or technician degree that the National Nursery and Obstetrics School (ENEO, UNAM) offers to the students of the traditional, open and incorporated systems. The purpose of this article is to share what has been done regarding the licentiate level EPAC since the Support Unit for Knowledge Evaluation was created. This has allowed, with the work of a multidisciplinary team, to improve the general exam process, to attain computer and administrative innovations and to give a direct, realiable educative support to both institutions and individual participants. The results shown in this article proceed from the four exams presented until the year 2006, which were judged based on descriptive, transversal studies with census sample. It is undeniable that the permanent work with this process will redirect the actions for a continuous improvement, that will allow high reliability standards that guarantee the attainment of more objective, convenient results.


Asunto(s)
Humanos , Masculino , Femenino , Historia del Siglo XIX , Historia del Siglo XX , Bachillerato en Enfermería , Enfermería
17.
Rev. cuba. endocrinol ; 14(1)ene.-abr. 2003.
Artículo en Español | LILACS, CUMED | ID: lil-628221

RESUMEN

Se presentan los resultados de la evaluación analítica de un ensayo de segunda generación (IRMA-I125-hTSH-BGTâ) producido y comercializado por el Centro de Isótopos. Se determina la sensibilidad analítica y funcional, intervalo de referencia, imprecisión y exactitud del diagnosticador. El método presentó sensibilidad analítica de 0,014 mUI/ L y funcional de 0,11 mUI/L. La imprecisión intraensayo fue de 4,34; 4,04 y 1,60 por ciento y la imprecisión interensayo de 12,96; 4,30; 5,98 y 10,21 por ciento para 4 sueros controladores de la calidad con concentraciones de 0,42; 9,77; 27,03 y 1,31 mUI/L, respectivamente. Los estudios de exactitud mostraron en la prueba de linealidad y paralelismo, rectas y coeficientes de correlación muy cercanos a 1 (E1, m = 0,992; r = 0,998 -C2, m = 1,008; r = 0,998 - C3, m =1,013; r = 0,999), sin que existieran diferencias significativas (p < 0,05) entre las pendientes ni entre las varianzas de las rectas descritas. Estas fueron paralelas entre sí; la recuperación media fue de 105,50 por ciento y la exactitud promedio de 102,75. El intervalo de referencia fue de 0,52-3,92 mUI/L; n = 215 y 95,33 por ciento. El método presenta sensibilidades analítica y funcional, correspondientes a los ensayos de hTSH de segunda generación, y es preciso y exacto. Dicho diagnosticador reúne los criterios analíticos para su comercialización en la red de laboratorios con servicios de endocrinologìa y medicina nuclear del país(AU)


The results of the analytical evaluation of a second-generation assay (IRMA-I125-hTSH-BGT®)) produced and commercialized by the Center of Isotopes are presented. Analytical and functional sensitivity, reference interval, imprecision and accuracy of the diagnostic method were determined. The method had an analytical and functional sensitivity of 0,014 mUI/ L and 0,11 mUI/L respectively. The intra-assay imprecision was 4,34; 4,04 y 1,60 percent and the interassay imprecision was 12,96; 4,30; 5,98 y 10,21 % for 4 quality control sera at concentrations of 0,42; 9,77; 27,03 y 1,31 mUI/L respectively. The accuracy studies showed in the linearity and parallelism test straight lines and correlation coefficients very close to 1 (E1, m= 0,992; r= 0,998 -C2, m= 1,008; r=0,998 - C3, m=1,013; r=0,999), without significant differences (p<0,05) among the slopes or among the variances of the described straight lines; they were parallel to each other. The median recovery was 105,50 percent and average accuracy was 102,75 percent. The reference interval was 0.52-3,92 mUI/L; n=215; 95,33 percent. The method presents analytical and functional sensitivity rates that match those of the second-generation hTSH assays in addition to being precise and accurate. This diagnostic method complies with the analytical criteria for it being commercialized in the laboratory network that provides endocrinology and nuclear medicine services throughout the country(AU)


Asunto(s)
Humanos , Juego de Reactivos para Diagnóstico , Tirotropina/efectos adversos , Sensibilidad y Especificidad , Gestión de la Calidad Total
18.
Rev. cuba. hematol. inmunol. hemoter ; 17(1): 59-64, ene.-abr. 2001.
Artículo en Español | LILACS | ID: lil-628473

RESUMEN

Los estudios de estabilidad de los reactivos frabricados a partir de anticuerpos monoclonales de origen murino, permiten establecer adecuadamente la vida de estos productos, y su realización constituye un requisito indispensable en el cumplimiento de las buenas prácticas de producción. Se usaron los métodos de hemaglutinación para medir la actividad biológica del producto Hemo-CIM® Anti-B expresada en la potencia, la avidez y la intensidad, frente a un panel de eritrocitos del grupo B y A1B, para demostrar más efectivamente cualquier deterioro del reactivo. Se estableció que la vida útil del hemoclasificador producido en el Centro de Inmunología Molecular es de 2 años con una temperatura de almacenamiento entre 2 y 8 oC. La evaluación que simula las condiciones a la que los usuarios someten a estos reactivos, demostró que el reactivo mantiene las características de calidad que se requieren para su uso. La estabilidad lograda con el Hemo-CIM® Anti-B es similar a la informada con el producto hemoclasificador monoclonal murino Hemo-CIM® Anti-A.


The stability studies of the reagents made from monoclonal antibodies of murine origin allow to establish the life of these products adequately and are an indispensable requisite for the fulfillment of the good practices of production. The hemagglutination methods were used to measure the biological activity of the Anti-B Hemo-CIMâ product expressed in the potency, avidity and intensity against a panel of erythrocytes of the group B and A1B in order to show in a more effective way any deterioration of the reagent. It was established that the useful life of the hemoclassifier produced at the Center of Mollecular Biology is of 2 years at a storage temperature between 2 and 8ºC. The evaluation that simulates the conditions to which the users subject these reagents showed that the reagent maintains the quality characteristics required for its use. The stability attained with the Anti-B Hemo-CIMâ is similiar to that reported with the murine monoclonal Anti-A Hemo-CIMâ hemoclassifier product.

19.
Rev. cuba. farm ; 32(1): 40-44, ene.-abr. 1998.
Artículo en Español | LILACS | ID: lil-628417

RESUMEN

Se estudió la estabilidad a largo plazo del juego de reactivos para la determinación de hemoglobina en sangre, basado en el comportamiento de la estabilidad física y química de los componentes del juego durante 1 año, así como también el ensayo funcional de éstos. Se estudió además el reactivo de trabajo durante 15 d. Un análisis estadístico de los resultados demostró que el juego de reactivos es estable durante los tiempos de estudio, almacenado a una temperatura de 2 a 8 EC.


The long term stability of the reagents kit to determine hemoglobin in blood, based on the physical and chemical stability of the components of the kit during a year, as well as their functional assay, were studied. The working resgent was also studied for 15 days. A statistical analysis of the results showed that the reagents kit is stable during the time under study, stored at a temperature from 2 to 8 EC.

20.
Rev. cuba. farm ; 30(1)ene.-abr. 1996.
Artículo en Español | LILACS | ID: lil-628410

RESUMEN

La determinación de lipoproteínas en suero constituye una valoración de interés para el pesquisaje de las hiperlipoproteinemias. Es muy importante contar con un método rápido, sencillo y con un reactivo confiable que asegure dicha valoración. Se presentan los resultados logrados en pruebas de terreno en la provincia Habana con el reactivo ß pre-ß lipoproteína producido en la Empresa de Productos Biológicos "Carlos J. Finlay" y se comparan con un juego de reactivos para la determinación de colesterol con el propósito de analizar su correlación; los resultados obtenidos son satisfactorios. El coeficiente de correlación fue de 0,9997.


Determination of serum lipoproteins is an interesting assessment for the investigation of hyperlipoproteinemia. It is very important to count on a fast and simple method, and with a reliable reagent, to secure such assessment. Here the authors present the results obtained in field tests in Havana province, with the tested ß pre-ß lipoprotein reagent, produced at the "Carlos J. Finlay" biological products enterprise, and these results are compared with a reagent kit for cholesterol determination, with the aim for analysing their correlation. The outcomes were satisfactory. The correlation rate was 0,9997.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA