RESUMEN
Abstract This study investigated the impact of 'storage condition' and 'period of storage' on selected physico-mechanical properties and fracture reliability of a resin-based composite (RBC). Specimens, prepared from a nanofilled RBC (Filtek Z350 XT; 3M ESPE), underwent tests for degree of conversion (DC), flexural strength (σ), flexural modulus (E), and hardness. The specimens were initially grouped into dry storage at 37°C or wet storage in distilled water at 37°C. Subsequently, they were further divided into four subgroups based on the period of storage: 6, 24, 72, or 168 hours. Specimens tested immediately after preparation served as control. Data analysis employed two-way ANOVA and Weibull analysis (α = 5%). Compared to the control, an increase in DC was observed only after 72 hours of dry storage; σ showed higher values after both dry and wet storage, regardless of the storage period (except for the group wet-stored for 168 hours); E increased with dry storage for at least 24 hours or wet storage for 72 hours; and hardness increased after dry storage for at least 24 hours or wet storage for up to 72 hours. The Weibull modulus remained unchanged under any of the distinct storage conditions. Dry storage resulted in greater characteristic strength than the control, whereas wet storage contributed to higher strength values only at shorter periods (up to 24 hours). Overall, the inherent properties of RBCs with a similar composition to that tested in this study may change with varying storage conditions and periods.
RESUMEN
RESUMO Objetivo Verificar os efeitos imediatos da fotobiomodulação sobre a pressão máxima dos lábios para diferentes doses. Método Estudo experimental, randomizado e triplo cego. A amostra foi composta por 23 mulheres e 17 homens com idade entre 18 e 33 anos (média 23,18 anos, DP=2,1), divididos em quatro grupos: GC (grupo controle), G1, G4 e G7. A pressão máxima foi avaliada com o Iowa Oral Performance Instrument (IOPI). O bulbo foi posicionado entre os lábios e os participantes foram orientados a pressioná-lo com a maior força possível. Aplicou-se o LASER infravermelho (808 nm) da marca DMC, modelo Therapy EC, 100 mW de potência. As doses testadas foram 1 J (G1), 4 J (G4) e 7 J (G7) aplicadas em seis pontos do músculo orbicular da boca. No GC não houve intervenção. Após a aplicação do LASER, foram repetidos os procedimentos de avaliação. Os resultados foram analisados com nível de significância de 95%. Resultados A pressão máxima de lábios aumentou significativamente apenas no grupo irradiado com 7 joules. Conclusão O LASER de baixa intensidade na dose de 7 J promoveu mudanças no desempenho do músculo orbicular da boca em tarefa de pressão máxima.
ABSTRACT Purpose To verify the immediate effects of different doses of photobiomodulation on maximum lip pressure. Methods Experimental, randomized and triple-blind study. The sample consisted of 23 women and 17 men, age between 18 and 33 years old (average 23.18 years old, SD=2.1), distributed in four groups: CG (control group), G1, G4 and G7. The maximum pressure was assessed with the Iowa Oral Performance Instrument (IOPI). The bulb was placed between the lips and the participants were instructed to press it as strong as possible. Infrared LASER (808 nm), manufactured by DMC, Therapy EC model, 100 mW of power output, was applied. The doses tested were 1 J (G1), 4 J (G4) and 7 J (G7), applied at six points of the orbicularis oris muscle. In the CG there was no intervention. The evaluation procedures were repeated after the LASER application. The results were analyzed with a significance level of 95%. Results The maximum lip pressure increased significantly only in the group irradiated with 7 J. Conclusion Low level LASER therapy with 7 J dose promoted changes in the performance of the orbicularis oris muscle in the maximum pressure task.
RESUMEN
Introduction: Coronary artery bypass grafting (CABG) causes changes in the respiratory musculature that affects functional capacity and postoperative complications (POC). Inspiratory muscle training (IMT) is a tool used for these patients, but it is not known what the best form is to increase strength. Objective: To investigate whether IMT with a linear pressure load device is superior to the inspiratory incentive on functional capacity and muscle strength of patients undergoing CABG. Methods: This is a clinical trial. Patients were assessed preoperatively for inspiratory muscle pressure (MIP), expiratory pressure (MEP), peak expiratory flow (PEF), six-minute walk test (6MWT) and functional independence measure (FIM). After surgery, they were divided into three groups: control group (CG), training group with linear pressure load (IMT) and inspiratory incentive group (IG). On the day of discharge, all patients had their previous variables reassessed. Results: The study included 56 patients, 31 (55.4%) were male and an average age of 55 ± 12 years. There was a significant reduction in all variables, in relation to MIP, the IMT showed a higher value in the postoperative period 83 ± 19 cmH2O, against 70 ± 15 cmH2O in the CG and 80 ± 15 cmH2O in the IG (p < 0.001). The same behavior was observed in MEP, 77 ± 12 cm H2O in IMT, 67 ± 14 cmH2O in CG and 75 ± 10 cmH2O in IG (p < 0.001). Regarding the 6 MWT, there was a lesser loss in the IMT from 434 ± 15 m to 398 ± 20 m in IG (p < 0.001). Conclusion: It is concluded that muscle training with a linear pressure load device is superior to training with incentive on functional capacity and muscle strength in patients undergoing CABG. (AU)
Introdução: A cirurgia de revascularização do miocárdio (CRM) causa alterações na musculatura respiratória que afetam a capacidade funcional e complicações pós-operatórias (DCP). O treinamento muscular inspiratório (TMI) é uma ferramenta utilizada por esses pacientes, mas não se sabe qual é a melhor forma de aumentar a força. Objetivo: Investigar se o TMI com dispositivo de carga de pressão linear é superior ao incentivo inspiratório na capacidade funcional e força muscular de pacientes submetidos à CRM. Métodos: Este é um ensaio clínico. Os pacientes foram avaliados no pré-operatório para pressão muscular inspiratória (PImáx), pressão expiratória (PEF), pico de fluxo expiratório (PFE), teste de caminhada de seis minutos (TC6) e medida de independência funcional (MIF). Após a cirurgia, eles foram divididos em três grupos: grupo controle (GC), grupo treinamento com carga linear de pressão (IMT) e grupo incentivo inspiratório (GI). No dia da alta, todos os pacientes tiveram suas variáveis anteriores reavaliadas. Resultados: O estudo incluiu 56 pacientes, 31 (55,4%) eram do sexo masculino e idade média de 55 ± 12 anos. Houve redução significativa em todas as variáveis, em relação à PImáx, o IMT apresentou valor maior no pós-operatório 83 ± 19 cmH2O, contra 70 ± 15 cmH2O no GC e 80 ± 15 cmH2O no GI (p < 0,001). O mesmo comportamento foi observado na PEmáx, 77 ± 12 cmH2O no IMT, 67 ± 14 cmH2O no GC e 75 ± 10 cmH2O no GI (p < 0,001). Em relação ao TC6, houve menor perda no TMI de 434 ± 15 metros para 398 ± 20 metros no GI (p < 0,001). Conclusão: Conclui-se que o treinamento muscular com dispositivo de carga pressórica linear é superior ao treinamento com incentivo inspiratório na capacidade funcional e da força muscular em pacientes submetidos à CRM. (AU)
Asunto(s)
Humanos , Modalidades de Fisioterapia , Fuerza Muscular , Revascularización Miocárdica , Periodo Posoperatorio , Capacidad Residual FuncionalRESUMEN
A perda gradativa da força muscular durante o período de senescência pode gerar graves consequências para a saúde, refletindo negativamente na qualidade de vida do idoso. Relacionou-se a força muscular e a qualidade de vida em idosos. Estudo descritivo e analítico, censitário, de delineamento transversal com caráter epidemiológico de base domiciliar e abordagem quantitativa, realizado com idosos residentes de um bairro em uma cidade do estado da Bahia. Foi aplicado um questionário com questões sociodemográficas, acrescido da Escala Mini Exame de Estado Mental para avaliação do estado cognitivo e a escala Medical Research Council para avaliar a força muscular e por fim foi utilizado o questionário SF-36 para verificar a qualidade de vida. Participaram do estudo 118 idosos; as correlações entre os domínios da qualidade de vida e a força muscular evidenciaram-se todas como positiva, sendo a maior o domínio "capacidade funcional" (r = 0,584), seguida por "aspectos sociais" (r = 0,395), "aspectos físicos" (r = 0,313) e "aspectos emocionais" (r = 0,282). Há uma relação entre força muscular e qualidade de vida na população idosa estudada, tanto nos aspectos gerais quanto nos domínios individualizados. (AU)
The gradual loss of muscle strength during the senescence period can generate serious health consequences, reflecting negatively on the quality of life of the elderly. Muscle strength and quality of life in the elderly have been related. Descriptive and analytical study, census, of transversal design with epidemiological character of home base and quantitative approach, carried through with elderly residents of a neighborhood in a city of the state of Bahia. A questionnaire with socio-demographic questions was applied, plus the Mini Mental State Examination Scale to assess the cognitive state and the Medical Research Council scale to assess muscle strength, and finally the SF-36 questionnaire was used to check the quality of life. 118 elderly participated in the study; the correlation between the domains of quality of life and muscle strength was all shown to be positive, the largest being "functional capacity" (r = 0.584), followed by "social aspects" (r = 0.395), "physical aspects" (r = 0.313) and "emotional aspects" (r = 0.282). There is a relationship between muscle strength and quality of life in the elderly population studied, both in general aspects and in individualized domains. (AU)
Asunto(s)
Humanos , Anciano , Anciano de 80 o más Años , Calidad de Vida , Anciano , Fuerza Muscular , EnvejecimientoRESUMEN
Objetivo: comparar a força de preensão manual (FPM) e a velocidade máxima da caminhada de acordo com o nível de atividade física (NAF) e o sexo em idosos centenários. Método: participaram do estudo 48 centenários (101,73±2,52 anos), sendo 29 mulheres e19 homens. Dados sociodemográficos, de saúde e hábitos de vida foram analisados por meio do Protocolo de Avaliação Multidimensional do Idoso Centenário PAMIC. A FPM foi mensurada por meio de dinamômetro, o NAF por meio de pedômetro e a velocidade máxima da caminhada por meio de teste físico. Foram classificados como centenários ativos os que atingiram no mínimo 1.000 passos/semana e como insuficientemente ativos aqueles abaixo deste valor. O nível de significância adotado foi de 5%. Resultados: centenários do sexo masculino apresentaram maior FPM direita (17,47±6,94kgf) e esquerda (16,63±6,28kgf) quando comparados ao sexo feminino (11,90±4,84kgf; 10,48±5,00kgf) (p<0,05). Quando analisados de acordo com o NAF, centenários ativos apresentaram maior FPM direita (22,86±8,01 kgf) e esquerda (22,14±5,55kgf) em comparação aos insuficientemente ativos (14,33±3,82kgf; 13,42±4,14kgf) (p<0,05). Para o sexo feminino, a FPM direita foi maior nas centenárias ativas (15,75±4,68kgf) quando comparadas às insuficientemente ativas (10,43±4,12kgf) (p=0,006). Na FPM esquerda, o grupo ativo apresentou maior valor médio (14,00±4,63 kgf) em comparação ao grupo insuficientemente ativo (9,14±4,55kgf) (p=0,017). A velocidade máxima da caminhada não apresentou diferença significativa de acordo com o NAF ou o sexo dos idosos. Conclusão: o estudo evidencia que a atividade física está intimamente relacionada a melhores valores de FPM, indicando que idosos centenários ativos possuem melhor força corporal global.(AU)
Aim: to compare the handgrip strength (HGS) and the maximum walking speed according to the level of physical activity (PA) and sex in elderly centenarians. Method: 48 centenarians (101.73 ± 2.52 years old) participated in the study, 29 women and 19 men. Sociodemographic, health, and lifestyle data were analyzed using the Multidimensional Assessment Protocol for the Elderly Centenary PAMIC. HGS was measured using a dynamometer, PA utilizing a pedometer, and the maximum gait speed through a physical test. Those who reached at least 1,000 steps/week were classified as active centenarians and those below this value as insufficiently active. The level of significance adopted was 5%. Results: centenarians of the male sex had higher HGS on the right (17.47 ± 6.94kgf) and left (16.63 ± 6.28kgf) when compared to the female sex (11.90 ± 4.84kgf; 10.48 ± 5, 00kgf) (p<0.05). When analyzed according to PA, active centenarians had a higher right (22.86 ± 8.01 kgf) and left (22.14 ± 5.55kgf) HGS compared to insufficiently active (14.33 ± 3.82kgf; 13, 42 ± 4.14 kgf) (p <0.05). For females, the right HGS was higher in active centenarians (15.75 ± 4.68kgf) when compared to insufficiently active women (10.43 ± 4.12kgf) (p = 0.006). In the left HGS, the active group had a higher mean value (14.00 ± 4.63 kgf) compared to the insufficiently active group (9.14 ± 4.55kgf) (p = 0.017). The maximum gait speed did not show any significant difference according to PA or the gender of the elderly. Conclusion: the study shows that physical activity is closely related to better values of HGS, indicating that active elderly centenarians have better overall body strength.(AU)
Asunto(s)
Anciano de 80 o más Años , Anciano de 80 o más Años , Envejecimiento , Ejercicio Físico , CentenariosRESUMEN
Abstract Researches that describe the anatomy and physiology of human movement have aimed to produce knowledge comparing women's and men's physical capacities, concerned with specifying and describing "sex differences." One of the consequences of this kind of research is that it influences teaching processes in human motion disciplines for physical educators, producing gender-marked bodies. This article uses Foucauldian discourse analysis to question how the production of sex differences is present in scientific studies dedicated to studying athletic performance that propose comparisons between sexes in strength performance. Through this analysis, we aim to describe and analyse how the epistemologies of sex and gender involved in these productions reinforce naturalised ideas of what it means to be a man and a woman, as well as question the social intelligibility of body/gender/sexuality that regulates sex/gender in our culture and in science.
Resumo Pesquisas que descrevem a anatomia e fisiologia do movimento humano têm objetivado produzir comparações entre capacidades físicas de homens e mulheres, para especificar e descrever "diferenças sexuais". Uma das consequências desse tipo de pesquisa é sua influência em pedagogias de ensino utilizadas por profissionais da educação física, produzindo a materialidade do gênero nos corpos. Esse artigo utiliza análise do discurso Foucaultiana para interrogar como a produção de diferenças sexuais ocorre em artigos científicos dedicados ao estudo de desempenho físico que comparam os sexos em relação à força. Através dessa análise, objetivamos descrever e analisar como epistemologias de sexo/gênero estão envolvidas nessa produção de forma a reiterar ideias naturalizadas do que significa ser homem e ser mulher, assim como também questionar a inteligibilidade de corpo/gênero/sexualidade que regula a materialização do sexo/gênero na cultura e na ciência.
Asunto(s)
Humanos , Masculino , Femenino , Educación y Entrenamiento Físico , Aptitud Física , Estereotipo de Género , Rendimiento Físico Funcional , Identidad de Género , Caracteres Sexuales , Fuerza Muscular , Sexismo , Normas de GéneroRESUMEN
Introdução: O acidente vascular encefálico (AVE) é a causa de diversas incapacidades neurológicas em adultos, o que torna necessário o melhor estudo de seu impacto na capacidade funcional. Objetivo: Avaliar a destreza motora funcional de membros superiores de hemiparéticos crônicos submetidos a Fisioterapia em Grupo no Formato de Circuito de Treinamento (FGCT), pois esta forma de tratamento tem se mostrado eficaz na melhora da capacidade funcional, o que torna necessário um estudo voltado para o membro superior. Métodos: Participaram 15 hemiparéticos em atendimento com FGCT. Foi realizada uma avaliação inicial (AV1) utilizando a escala de Ashworth Modificada, o teste de caixa de blocos, e o nine hole peg test. Após 12 semanas de intervenção com FGCT foi realizada a avaliação final (AV2) utilizando os mesmos testes. Resultados: A análise estatística considerou p > 0,05 e não revelou diferença significante entre AV1 e AV2 na dinamometria bem como no teste de caixa de blocos e nine hole peg test. Conclusão: O protocolo terapêutico não determinou a melhora da destreza motora funcional de membros superiores de hemiparéticos crônicos submetidos a fisioterapia de grupo no formato de circuito de treinamento. (AU)
Introduction: Stroke is the cause of several neurological disabilities in adults, which makes it necessary to better study the impact on functional capacity. Objective: The objective was to evaluate the motor dexterity performance of upper limbs in chronic hemiparetic submitted to Group Physiotherapy in the Training Circuit (GPTC) format, as this form of treatment has been shown to be effective in the improvement functional capacity, which makes it necessary a study aimed at the upper limb. Methods: Fifteen hemiparetic patients in our service with GPTC participated. An initial assessment (IA1) was performed using the Modified Ashworth scale, Box and Block Test (BBT), and the 9-Hole Peg Test (9-HPT). After 12 weeks of intervention with GPTC, the final evaluation (FE2) was performed using the same tests. Results: Statistical analysis considered p > 0.05 and did not reveal a significant difference between IA1 and FE2 in hand-held dynamometry as well as in the BBT and 9-HPT. Conclusion: The therapeutic protocol did not determine the improvement of the motor dexterity of upper limbs in chronic hemiparetic patients submitted to GPTC. (AU)
Asunto(s)
Humanos , Paresia , Modalidades de Fisioterapia , Extremidad Superior , Destreza Motora , Fuerza MuscularRESUMEN
Abstract Introduction: The impairment of muscle strength and fatigue in leprosy remains a problem that requires careful attention to avoid or minimize its progression, as well as prevention of disabilities and deformities. Objective: To investigate the maximum voluntary contraction and time to muscle fatigue in leprosy patients. Method: A total of 21 leprosy patients and 21 healthy subjects completed the sample. The method used to determine the maximum voluntary contraction (MVC) of the handgrip followed the recommendation of the American Society of Hand Therapists with the use of a hydraulic hand grip dynamometer. The test was performed three times with each hand, with a time interval of 60 seconds between successive trials. The subject was instructed to perform a maximal isometric force against the dynamometer for 5 seconds. The peaks were recorded and used for the fatigue test. For the fatigue test, we recorded the electromyogram of the forearm muscles to offline determine the onset time for the muscle contraction (14 bits, Miograph 2 USB®, Miotec, Brazil). Results: Leprosy patients had lower MVC compared with healthy subjects (p > 0.05), both in the dominant and the non-dominant hands. The time to fatigue in the leprosy and control groups was similar (p < 0.05). We observed that leprosy patients had more contractions than the healthy subjects (22.6 ± 11.8 contractions for the leprosy group vs. 12.3 ± 6.9 contractions for the control group, p > 0.05). Conclusion: Multibacillary leprosy patients lost muscle force without modifying the resistance to fatigue.
Resumo Introdução: O comprometimento da força muscular e a fadiga na hanseníase continuam sendo problemas que requerem cuidadosa atenção para evitar ou minimizar sua progressão, bem como prevenir incapacidades e deformidades. Objetivo: Avaliar a força muscular e o tempo até a fadiga em pacientes com hanseníase Método: Vinte e um pacientes com hanseníase e 21 indivíduos saudáveis completaram a amostra. O método utilizado para determinar a contração voluntária máxima (CVM) da força de preensão palmar seguiu a recomendação da Sociedade Americana de Terapeutas da Mão com o uso de um dinamômetro de preensão manual. O teste foi realizado três vezes em cada mão, com intervalo de tempo de sessenta segundos entre tentativas sucessivas. O sujeito foi instruído a realizar força isométrica máxima contra o dinamômetro durante cinco segundos. Os picos foram registrados e usados para o teste de fadiga. Para o teste de fadiga, registrou-se o eletromiograma dos músculos do antebraço para determinar off-line o tempo de início da contração muscular (14 bits, Miograph 2 USB ® , Miotec, Brasil). Resultados: Os pacientes com hanseníase apresentaram menor CVM em relação aos saudáveis (p < 0,05) nas mãos dominante e não dominante. Não houve diferença no tempo de fadiga entre os grupos hanseníase e controle (p > 0,05). Foi observado que os pacientes com hanseníase tinham mais contrações do que os saudáveis (22,6 ± 11,8 contrações para o grupo com hanseníase vs. 12,3 ± 6,9 para o grupo controle, p < 0,05). Conclusão: Pacientes com hanseníase multibacilar apresentaram perda de força muscular sem modificação da resistência à fadiga.
Resumen Introducción: El compromiso de la fuerza muscular y la fatiga en la lepra sigue siendo un problema que requiere atención cuidadosa para evitar o minimizar su progresión, así como la prevención de incapacidades y deformidades. Objetivo: Evaluar la fuerza muscular y el tiempo hasta la fatiga de pacientes con lepra. Método: Veintiún pacientes con lepra y 21 sujetos sanos completaron la muestra. El método utilizado para determinar la contracción voluntaria máxima (CVM) de la fuerza de asimiento palmar siguió la recomendación de la Sociedad Americana de Terapeutas de la Mano con el uso de un dinamómetro de asimiento manual. La prueba se realizó tres veces con cada mano, con un intervalo de tiempo de 60 segundos entre intentos sucesivos. El sujeto fue instruido a realizar una fuerza isométrica máxima contra el dinamómetro durante 5 segundos. Los picos se registraron y se utilizaron para la prueba de fatiga. Para la prueba de fatiga, registramos el electromiograma de los músculos del antebrazo para determinar fuera de línea el tiempo de inicio de la contracción muscular (14 bits, Miograph 2 USB ® , Miotec, Brasil). Resultados: Los pacientes con lepra presentaron menor CVM con relación a los sanos (p < 0,05) en las manos dominante y no dominante. No hubo diferencia en el tiempo de fatiga entre los grupos de lepra y control (p > 0,05). Se observó que los pacientes con lepra tenían más contracciones que los sanos (22,6 ± 11,8 contracciones para el grupo con hanseniasis frente a 12,3 ± 6,9 para el grupo control, p < 0,05). Conclusión: Pacientes con hanseniasis multibacilar presentaron pérdida de fuerza muscular sin modificación de la resistencia a la fatiga.
Asunto(s)
Humanos , Masculino , Femenino , Fatiga Muscular , Lepra , Sistema Musculoesquelético , Fuerza Muscular , Tono MuscularRESUMEN
Objetivo: Conhecer o perfil pulmonar, muscular e funcional de pacientes com doença renal crônica (DRC) e verificar a relação entre a força muscular periférica e a capacidade funcional desses pacientes. Métodos: 21 pacientes com DRC e 17 saudáveis foram avaliados quanto à antropometria, função pulmonar, força muscular periférica e capacidade funcional. Para comparação entres os grupos foi utilizado o teste t de Student ou U de Mann Whitney. Para correlacionar a força muscular periférica com a capacidade funcional do grupo DRC utilizou-se o coeficiente de Pearson ou Spearman. Resultados: Houve diferença estatisticamente significativa entre os grupos DRC e saudável, respectivamente, nas variáveis da função pulmonar: volume expiratório forçado no primeiro segundo (77,62 ± 18,05% vs. 99,71 ± 16,43%; p = 0,001) e capacidade vital forçada (78,86 ± 17,16% vs. 98,48 ± 16,99%; p = 0,001); e na força muscular periférica de quadríceps direito (127,76 ± 49,77 Nm vs. 170,90 ± 55,38 Nm; p = 0,006) e esquerdo (134,10 ± 55,19 Nm vs. 171,05 ± 57,86 Nm; p = 0,04). O teste de caminhada de 6 minutos foi menor no grupo DRC comparado ao saudável em valor absoluto (419,95 ± 98,51m vs. 616,90 ± 90,01m; p < 0,0001) e em % do predito (66,07 ± 15,04% vs. 94,80 ± 9,35%; p < 0,0001). Observou-se correlação moderada entre a capacidade funcional e a força muscular periférica de quadríceps direito (rho = 0,52; p = 0,01) e quadríceps esquerdo (r = 0,63; p = 0,002) no grupo DRC. Conclusão: Pacientes com DRC apresentam alteração na função pulmonar, redução da força muscular periférica e da capacidade funcional. (AU)
Objective: To study the pulmonary, muscular and functional profile of patients with chronic kidney disease (CKD) and verify the correlation between peripheral muscle strength and functional capacity of these patients. Methods: 21 patients with CKD and 17 healthy individuals were evaluated for anthropometry, pulmonary function, peripheral muscle strength and functional capacity. In the comparison between the groups, the Student t test or the Mann Whitney U test were used. Correlation of peripheral muscle strength with the functional capacity of the CKD group was tested by the Pearson or Spearman coefficient. Results: There was a statistically significant difference between the CKD and healthy groups, respectively, in the pulmonary function variables: forced expiratory volume in the first second (77.62 ± 18.05% vs. 99.71 ± 16.43%, p = 0.001) and forced vital capacity (78.86 ± 17.16% vs. 98.48 ± 16.99%, p=0.001); and right quadriceps muscle strength (127.76 ± 49.77 Nm vs. 170.90 ± 55.38 Nm, p = 0.006) and left quadriceps (134.10 ± 55.19 Nm vs. 171.05 ± 57.86 Nm; p = 0.04). The 6-minute walk test was lower in the CKD group compared to healthy in absolute values (419.95 ± 98.51 m vs. 616.90 ± 90.01 m, p < 0.0001) and in % predicted (66,07 ± 15.04% vs. 94.80 ± 9.35%, p<0.0001). There was a moderate correlation between functional capacity and muscle strength of right quadriceps (rho = 0.52, p = 0.01) and left quadriceps (r = 0.63, p = 0.002) in the CKD group. Conclusion: Patients with CKD have altered pulmonary function, reduced peripheral muscle strength and functional capacity. (AU)
Asunto(s)
Humanos , Espirometría , Diálisis Renal , Tolerancia al Ejercicio , Insuficiencia Renal Crónica , Fuerza Muscular , Capacidad Pulmonar Total , Capacidad Vital , Antropometría , Volumen Espiratorio Forzado , Capacidad Residual FuncionalAsunto(s)
Humanos , Masculino , Femenino , Deportes , Enfermedades Cardiovasculares , Ejercicio Físico , Factores de Riesgo , Muerte Súbita Cardíaca , HipertensiónRESUMEN
O aumento da expectativa de vida acarreta, muitas vezes, a prevalência de algumas doenças crônico-degenerativas relacionadas ao envelhecimento, como osteoporose e sarcopenia. Trata-se de pesquisa retrospectiva e prospectiva, com abordagem quantitativa do tipo quase-experimental com pré- e pós-teste, sem grupo-controle, utilizando-se um protocolo de exercícios na fisioterapia aquática. Amostra com 13 mulheres, entre 57 e 84 anos, com diagnóstico médico de osteopenia/osteoporose, comprovado por densitometria óssea. Aplicado protocolo no meio aquático, em 30 semanas, 2 vezes na semana; participantes submetidas a avaliações pré- e pós-intervenção, avaliando-se a força muscular por meio do torque músculo quadríceps com a dinamometria, e a sarcopenia, pelo teste Short Physical Performance Battery (SPPB). Os resultados, após o protocolo de fisioterapia aquática, mostraram que o torque de ambos os lados foi estatisticamente significativo; porém, o lado não dominante (p=0,0059) apresentou maior ganho de força em relação ao membro dominante (p=0,01). Os resultados da sarcopenia também foram estatisticamente significativos após protocolo aquático (p = 0,03458), do que se pode concluir que a fisioterapia aquática se mostra eficaz no torque muscular e sarcopenia.
The increase in life expectancy often leads to the prevalence of some chronic-degenerative diseases related to aging, such as osteoporosis and sarcopenia. This is a retrospective and prospective research, with quantitative approach of the quasi-experimental kind, with pre- and post-test, without control group, using a protocol of exercises in aquatic physiotherapy. Sample with 13 women, between 57 and 84 years old, with a medical diagnosis of osteopenia / osteoporosis, confirmed by bone densitometry. A protocol was applied in aquatic mean, with the duration of 30 week, twice a week. The participants were submitted to pre and post-intervention evaluations, measuring their muscle force through torque of quad muscle with dynamometry, and sarcopenia through Short Physical Performance Battery (SPPB) test. The results, after the aquatic physiotherapy protocol, showed that the torque on both sides was statistically significant; however, the non-dominant side (p = 0.0059) showed greater strength gain compared to the dominant member (p=0.01). The results of sarcopenia were also statistically significant after aquatic protocol (p=0.03458), from which it can be concluded that aquatic physiotherapy is effective in muscle torque and sarcopenia.
El aumento de la esperanza de vida a menudo conduce a la prevalencia de algunas enfermedades crónicas degenerativas relacionadas con el envejecimiento, como la osteoporosis y la sarcopenia. Este es un estudio retrospectivo y prospectivo, con un enfoque cuantitativo cuasi-experimental con prueba previa y posterior, sin un grupo de control, utilizando un protocolo de ejercicio en fisioterapia acuática. Muestra con 13 mujeres, entre 57 y 84 años, con diagnóstico médico de osteopenia / osteoporosis, confirmado por densitometría ósea. Protocolo aplicado en el medio acuático, en 30 semanas, dos veces por semana; Los participantes se sometieron a evaluaciones previas y posteriores a la intervención, evaluando la fuerza muscular utilizando el torque muscular del cuádriceps con dinamometría y sarcopenia, utilizando la prueba de la Batería de rendimiento físico corto (SPPB). Los resultados, después del protocolo de fisioterapia acuática, mostraron que el torque en ambos lados fue estadísticamente significativo; sin embargo, el lado no dominante (p = 0.0059) mostró una mayor ganancia de fuerza en comparación con el miembro dominante (p = 0.01). Los resultados de la sarcopenia también fueron estadísticamente significativos después del protocolo acuático (p=0.03458), a partir del cual se puede concluir que la fisioterapia acuática es efectiva en el torque muscular y la sarcopenia.
Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Mujeres , Torque , Sarcopenia , Terapia AcuáticaRESUMEN
A avaliação da aptidão física contribui para prescrição clínica do exercício. O objetivo foi avaliar e correlacionar componentes da aptidão física. Estudo transversal com 331 idosos de grupos de convivência (≥ 60 anos), estratificados por sexo, faixa etária, avaliados pela bateria Testes de Aptidão Física para Idosos (TAFI). Resultados foram analisados pela ANOVA One Way, correlação de Pearson, Regressão simples e múltipla. Em idosas a força de membros inferiores (MMII) apresentou correlação com flexibilidade e explicou agilidade/equilíbrio. Força de membros superiores (MMSS) associou-se com flexibilidade de MMSS, 12% da flexibilidade pode explicar a força de MMSS. No sexo masculino, força de MMII correlacionou-se com resistência aeróbica e explicou 55% da resistência aeróbica. Conclui-se que no sexo feminino com aumento da idade, a força/resistência dos MMII associou-se de maneira crescente com agilidade/equilíbrio dinâmico, já no sexo masculino a força dos MMII associou-se com a resistência aeróbica. (AU)
The evaluation of physical fitness contributes to clinical prescription of the exercise. The objective was to evaluate and correlate components of physical fitness. Cross-sectional study with 331 elderly (≥ 60 years) stratified by gender, age groups, evaluated by Senior Fitness Test. Results were analyzed by One Way ANOVA, Pearson's correlation and multiple and simple regression. In women, strength/resistance of lower limbs (LL) presented correlation with flexibility of LL and explained agility/balance. Strength of upper limbs (UL) was associated with UL flexibility, 12% of flexibility can explain the strength/resistance of UL. In men, strength/resistance of LL showed correlation with aerobic resistance and explained 55% of aerobic resistance. We concluded that older women showed strength/endurance of LL increasingly associated with agility/dynamic balance, while in male, strength/endurance of the LL was related to aerobic endurance. (AU)
Asunto(s)
Humanos , Masculino , Femenino , Anciano , Aptitud Física , Docilidad , Extremidad Inferior , Extremidad Superior , Equilibrio Postural , Fuerza MuscularRESUMEN
Introdução: Com a dificuldade de obtenção de dentes humanos para estudos in vitro, autores relatam e preconizam o uso de dentes extraídos de arcadas bovinas para testar técnicas de diferentes segmentos da Odontologia. Entretanto, para que as pesquisas tenham eficácia científica, estes dentes necessitam tratamento adequado para manter suas características e simular condições in vivo. Objetivo: Analisar a resistência de união (RU) adesiva à dentina em dentes bovinos restaurados com adesivo convencional Adper® Single Bond 2 (3M ESPE, St. Paul, MN, EUA) e compósito Opallis Flow (Dentscare LTDA., Joinville, SC, BRA), tendo como fatores de estudo solução e tempo de armazenamento. Metodologia: As amostras foram congeladas sob armazenamento em 2 soluções: timol 0,1% e cloramina 0,5%, em 4 diferentes períodos: 1 semana, 1 mês, 3 meses e 6 meses. Foram obtidos 8 grupos experimentais (n=64) e 1 grupo controle (n=8), totalizando 9 grupos. Após o período de restauração, os dentes foram armazenados em estufa a 37 ºC, imersos em água destilada e, em seguida, testados em máquina de ensaios universal (EMIC DL 500, São José dos Pinhais, PR, Brasil), com análise estatística dos resultados. Resultado: A comparação entre os grupos experimentais e controle mostrou diferença estatisticamente significante (p<0,05) para o armazenamento das amostras em timol durante o período de 1 mês. Conclusão: Os fatores solução e tempo foram capazes de alterar a resistência de união adesiva à dentina bovina, observando-se que a maior média de RU foi obtida após o armazenamento na solução timol durante 1 mês (p=0,004).
Introduction: With the difficulty of obtaining human teeth for in vitro studies, authors report and recommend the use of teeth extracted from bovine arches to test techniques from different segments of Dentistry. However, for research to be scientifically effective, these teeth need adequate treatment to maintain their characteristics and to mimic conditions in vivo. Objective: Analyze the adhesive bond strength (RU) to dentin in bovine teeth restored with Adper® Single Bond 2 (3M ESPE, St Paul, MN, USA) and Opallis Flow composite adhesive (Dentscare LTDA, Joinville, SC, BRA), taking as study factors solution and storage time. Methodology: The samples were frozen under storage in 2 solutions: 0.1% thymol and 0.5% chloramine, in 4 different periods: 1 week, 1 month, 3 months and 6 months. Eight experimental groups (n = 64) and one control group (n = 8) were obtained, totaling 9 groups. After the restoration period, the teeth were stored in an incubator at 37ºC, immersed in distilled water and then tested in a universal testing machine (EMIC DL 500, São José dos Pinhais, PR, Brazil), with statistical analysis of the results. Result: The comparison between the experimental and control groups showed a statistically significant difference (p <0.05) for the storage of thymol samples during the 1 month period. Conclusion: Solution and time factors were able to change the adhesive bond strength to the bovine dentin, observing that the highest mean of RU was obtained after storage in the thymol solution for 1 month (p = 0.004).
Asunto(s)
Animales , Bovinos , Timol , Técnicas In Vitro , Bovinos , Resistencia al Corte , DentinaRESUMEN
Objetivo: Correlacionar o pico de torque isocinético e a impulsão vertical durante a execução do bloqueio e do ataque de atletas de voleibol feminino. Métodos: Realizou-se um estudo quantitativo, descritivo de correlação, foram avaliadas 11 atletas da equipe adulta de voleibol feminino. O pico de torque foi avaliado no aparelho Biodex system 3, em duas velocidades angulares: 60 o/s e 300 o/s e para avaliação da impulsão vertical foi executado o counter movement jump. Resultados: As atletas apresentaram uma correlação moderada e significativa ao relacionar o pico de torque e a impulsão vertical durante o fundamento de ataque no flexor direito a 60 º/s com r=0.609; p=0.047, extensor esquerdo 300 º/s com r=0.664; p=0.026. Conclusão: Dessa forma o presente estudo apresentou uma moderada correlação entre o pico de torque isocinético e a impulsão vertical durante o fundamento de ataque das atletas de voleibol.
Objective: To correlate the peak isokinetic torque and vertical impulsion during the execution of the blockade and the attack of female volleyball athletes. Methods: A quantitative, descriptive correlation study was carried out. Eleven athletes from the adult female volleyball team were evaluated. The torque peak was evaluated in the Biodex system 3, at two angular velocities: 60 o / s and 300 o / s and for the vertical impulse evaluation the counter movement jump was performed. Results: The athletes had a moderate and significant correlation in relation to the peak torque and the vertical impulse during the right flexor attack at 60 º/s with r=0.609; p=0.047, left extensor 300 º/s with r=0.664; p=0.026. Conclusion: In this way the present study presented a moderate correlation between the peak of isokinetic torque and the vertical impulse during the attack foundation of the volleyball athletes.
Asunto(s)
Humanos , Femenino , Adolescente , Adulto , Adulto Joven , Fuerza Muscular , Epidemiología Descriptiva , TorqueRESUMEN
RESUMO O objetivo deste estudo foi avaliar os efeitos de um protocolo de fadiga dos músculos extensores de punho na força de preensão e da pinça lateral através da dinamometria e eletromiografia de superfície (EMG). Foram selecionados 40 indivíduos do sexo masculino, divididos em dois grupos: preensão ou pinça lateral. O protocolo de fadiga foi baseado no teste de 1 Repetição Máxima (1-RM), seguido da realização do movimento de extensão de punho repetidas vezes com carga de 75% da 1-RM. Os voluntários realizaram as tarefas de preensão ou pinça lateral associadas à dinamometria. A EMG foi realizada para ambos os grupos, analisando o comportamento, segundo o protocolo, pela frequência mediana (FM) do extensor radial do carpo (ERC), do extensor ulnar do carpo (EUC) e do flexor superficial dos dedos (FD). A dinamometria de preensão ou pinça lateral e a EMG foram realizadas antes e após o protocolo de fadiga para ambos os grupos. O protocolo de fadiga foi eficaz na diminuição da força de preensão palmar (43,5±3,85 kgf inicial e 36,50±5,1 kgf final) e da pinça lateral (10,26±1,01 kgf inicial e 8,54±0,86 kgf final), bem como na diminuição da FM, sugerindo uma condição de fadiga do EUC no grupo preensão. Os achados do presente estudo possibilitam relacionar a fadiga dos extensores de punho à diminuição de força em atividades funcionais, como a preensão, o que pode implicar em disfunções musculoesqueléticas do membro superior.
RESUMEN En este estudio se evalúa los resultados de un protocolo de fatiga de los músculos extensores de muñeca en la fuerza de presión y de pinza empleando la dinamometría y la electromiografía de superficie (EMG). Se eligieron a cuarenta hombres, los cuales fueron divididos en dos grupos: el de presión y el de pinza lateral. Se basó el protocolo de fatiga en la prueba de 1 Repetición Máxima (1RM), y se realizó el movimiento de extensión de muñeca muchas veces con carga del 75% de la 1RM. Los participantes realizaron la tarea de prensión o de pinza lateral asociada a la de dinamometría. La EMG fue realizada por ambos grupos, en los que se evaluó el comportamiento ante el protocolo de la frecuencia mediana (Fm) del extensor radial del carpo (ERC), del extensor cubital del carpo (ECC) y del flexor superficial de los dedos (FD). Se realizaron la dinamometría de presión o de pinza lateral y la EMG antes y después del protocolo de fatiga en ambos grupos. El protocolo de fatiga fue eficaz en la disminución de la fuerza de presión palmar (43,5±3,85 kgf inicial y 36,50±5,1 kgffinal) y de pinza lateral (10,26±1,01 kgf inicial y 8,54±0,86 kgf final), así como en la disminución de la Fm, lo que demuestra una condición de fatiga del ECC en el grupo de presión. Los resultados de este estudio permiten relacionar la fatiga de los extensores de muñeca a la disminución de fuerza en las actividades funcionales, lo que puede causar trastornos musculoesqueléticos del miembro superior.
ABSTRACT The objective of this study was to evaluate the effects of a wrist extensor muscles fatigue protocol at the handgrip and lateral pinch strength through dynamometry and surface electromyography (EMG). Forty male individuals were divided into two groups: handgrip and lateral pinch group. The fatigue protocol was based on the 1 Maximal Repetition (1-MR) test, followed by wrist extension movement repeated multiple times with a load of 75% of 1-MR. The volunteers performed hand grip and lateral pinch with a dynamometer. Surface EMG was performed by both groups to analyze the behavior of median frequency (MF) during a fatigue protocol. The muscles extensor carpi radialis longus and brevis, extensor carpi ulnaris, extensor digitorum and flexor digitorum superficialis were analyzed. The strength and EMG evaluations were carried out before and after the fatigue protocol in both groups. The fatigue protocol was effective on hand grip strength reduction (43.5±3.85 kgf in baseline and 36.50±5.1 kgf final) and lateral pinch strength reduction (10.26±1.01 kgf in baseline and 8.54±0.86 kgf final) (p<0.05, 95% CI). At the EMG analysis, using median frequency, an ulnaris carpal extensor muscle fatigue at the handgrip group was evidenced. The findings indicate that wrist extensors fatigue can decrease the strength in functional activities such as handgrip, resulting in upper limb dysfunctions.
RESUMEN
Este estudo teve como objetivo comparar o desempenho no teste de uma repetição máxima nos exercícios de supino reto com barra e supino reto com halteres. O estudo é do tipo quase experimental, com desenho cross-over. Participaram 10 indivíduos adultos do sexo masculino, saudáveis, com experiência mínima de seis meses em treinamento resistido. Os voluntários foram submetidos ao teste de uma repetição máxima nos respectivos exercícios de supino. Para comparar o desempenho da força entre os exercícios, foi utilizada a Análise Univariada de Covariância, com a idade e o índice de massa corporal sendo covariáveis. A análise estatística foi realizada por meio do SPSS 21.0, sendo adotado um valor significante de p<0,05. Foi verificado um tamanho do efeito de Cohen (d=0,7), e uma diferença significativa entre os exercícios (p<0,001), com o supino reto com barra apresentando maior valor médio (84,4 ± 13,50) em relação aos halteres (70,2 ± 8,87). Não houve interação da idade (p<0,69) e do índice de massa corporal (p<0,40) com a performance nos exercícios. Os resultados demonstraram melhor desempenho da força no supino reto com barra em relação aos halteres...(AU)
The aim of this study was to compare the test performances of one repetition maximum in the barbell bench press and dumbbell bench press exercises. The study has a quasi experimental design, with a cross-over design. Participants included 10 healthy men, with minimum experience of six months of resistance training. Participants performed their respective one repetition maximum bench press exercise. To compare strength performance between exercises, was used the Univariate Analysis of Covariance, being age and body mass index covariates. Statistical analysis was performed through SPSS 21.0, being adopted a significant value of p <0.05.A Cohen effect size was verified (p = 0.7), and a significant difference between exercises (p <0.001), with the barbell bench press having a greater average value (84.4 ± 13.50) compared to dumbbells (70.2 ± 8.87). There was no interaction of age (p <0.69) and body mass index (p <0.40) with the performance in the exercises. The results showed greater strength performance in the barbell bench press compared to dumbbells.
Asunto(s)
Humanos , Masculino , Rendimiento Atlético , Fuerza Muscular , Entrenamiento de Fuerza , Extremidad SuperiorRESUMEN
ABSTRACT: Often fractures of long bones in horses are comminuted and form bone gaps, which represent a major challenge for the fixation of these fractures by loss of contact between the fragments. Bone grafts help in treating this kind of fracture and synthetic materials have been gaining ground because of the limitations of autologous and heterologous grafts. In this study were performed compressive non destructive test in 10 bones with complete cross-bone gap in mid-diaphyseal of the third metacarpal bone of horses. Using a mechanism of "crossing" the 10 bones were used in the three groups (control, castor oil poliuretane and chitosan) according to the filling material. After the test with maximum load of 1000N bone had a gap filled by another material and the test was repeated. Deformations caused on the whole bone, plate and bone tissue near and distant of gap were evaluated, using strain gauges adhered to the surface at these locations. There was a reduction in bone deformation from 14% (control) to 3,5% and 4,8% by filling the gap with Chitosan and castor oil respectively, and a reduction of strain on the plate of 96% and 85% by filling gap with chitosan and castor respectively. An increase in intensity and direction of deformations occurred in bone near to gap after its filling; however, there was no difference in bone deformations occurring far the gap.
RESUMO: Frequentemente, as fraturas de ossos longos nos equinos são cominutivas, formando falhas ósseas, que representam um grande desafio no momento de sua fixação, devido à perda de contato entre os fragmentos. Os substitutos ósseos sintéticos auxiliam no tratamento desse tipo de fratura. Neste estudo, foram realizados ensaios compressivos não destrutivos em 10 ossos com falha óssea transversal completa em diáfise do terceiro metacarpiano de equinos. Utilizando um mecanismo de "crossing", os 10 ossos foram utilizados nos três grupos (controle, mamona e quitosana) de acordo com o material de preenchimento da falha. Para cada peça, realizaram-se ensaios referentes aos três grupos, com carga máxima de 1000N, por não se tratarem de ensaios destrutivos. Foram avaliadas as deformações causadas no osso, na placa e no tecido ósseo próximo e distante da falha, por meio de extensômetros. Observou-se que houve redução da deformação do osso de 14% (controle) para 3,5% e 4,8%, com o preenchimento da falha com quitosana e mamona, respectivamente. Houve redução da deformação na placa de 96% e 85% com o preenchimento da falha com quitosana e mamona, respectivamente. Houve aumento em intensidade e direção das deformações ocorridas no osso próximas à falha após seu preenchimento, contudo não se observaram diferenças nas deformações ocorridas no osso distantes a falha. Dessa forma, conclui-se que o preenchimento das falhas com quitosana e poliuretana de mamona trouxe benefícios quanto à redução das deformações no foco da fratura, alívio das cargas na placa, contudo elevou as cargas no tecido ósseo próximo à falha.
RESUMEN
Objetivo: Avaliar a resistência de união entre a resina composta e diferentes substratos de esmalte: hígido, esmalte desmineralizado submetido ou não a remineralização, e desmineralizado infiltrado com Icon (DMG). Material e Métodos: 120 dentes bovinos, cujas raízes foram removidas e o esmalte vestibular foi lixado. Os espécimes foram divididos em: Grupo A, controle, (n=24) que recebeu os procedimentos adesivos e restauradores para posterior teste de microtração; Grupo B (n=96), onde os corpos de prova (cdps) permaneceram imersos em solução desmineralizadora para produzir lesões subsuperficiais de cárie artificial, sendo subdividido em 4: B1, cdps somente desmineralizados; B2, cdps imersos em saliva artificial (8 semanas); B3, cdps imersos em solução de fluoreto 0,05% (1 minuto diariamente por 8 semanas); B4, cdps infiltrados com material resinoso (Icon, DMG). Todos os grupos receberam aplicação do sistema adesivo Clearfil S3 Bond Plus (Kuraray) ou Single Bond Universal (3M ESPE), seguida da resina composta Filtek Z 350 XT (3M ESPE). Os espécimes foram submetidos a ciclagem térmica e seccionados em prismas com dimensões aproximadas de 1mm² de base e submetidos ao teste de microtração. Resultados: os dados foram submetidos à ANOVA e ao Teste de Tukey (α= 5%).As médias em Mpa (±desvio padrão) foram: Clearfill S3 Bond Plus: Grupo Controle (17,17±3,52); B1 (11,60±0,74); B2 (6,83±1,87); B3 (8,38±1,59) e B4 (27,00±1,76); Single Bond Universal: Grupo Controle (26,26±3,19); B1 (10,94±2,00); B2 (11,05±1,74); B3 (15,63±1,25) e B4 (22,60±2,29). Conclusão: a superfície infiltrada com Icon não interferiu negativamente na resistência de união da resina composta ao esmalte e os grupos que foram desmineralizados e remineralizados com flúor e saliva artificial apresentaram valores estatisticamente inferiores aos demais.
Objective: To evaluate the bond strength between resin composite and differentenamel substrates: sound enamel; demineralized enamel submitted or not to remineralization; and demineralized enamel infiltrated with an infiltrating resin. Materials and Methods: 120 bovine teeth were selected, the root portion was removed and the enamel finished. Specimens were divided into the following groups:(A) Control (n=24): adhesively treated and restored; (B) (n=96): the samples were immersed in a demineralization solution to create white spot lesions and divided into four subgroups: (B1)demineralized enamel; (B2) samples were stored in artificial saliva (8 weeks); (B3) samples were stored in a 0.05% sodium fluoride solution (1 minday/8 weeks); (B4) samples were treated with an infiltrantresin (Icon, DMG). The groups were treated with one of the following adhesives: Clearfil S3 Bond Plus (Kuraray) or Single Bond Universal (3M ESPE), followed by the resin composite application (Filtek Z 350 XT, 3M ESPE). The specimens were submitted to thermalcycling aging (10,000 ×; 2±5ºC, 50±55ºCand 37°±2°C). The specimens were sectioned into prism shapes with ~1mm² of base and submitted tomicrotensile test. The collected data were submitted to ANOVA and Tukey´s test (α= 5%). Results: The Means (±SD) in MPawere: Clearfill S3 BondPlus: Control (17.17±3.52); B1 (11.60±0.74); B2 (6.83±1.87); B3 (8.38±1.59) and B4 (27.00±1.76);Single Bond Universal: Control (26.26±3.19); B1 (10.94±2.00); B2 (11.05±1.74); B3 (15.63±1.25) and B4 (22.60±2.29). Conclusion: The surfaceinfiltrated withaninfiltrating resin(Icon) did not negatively affect the bond strength between resin composite and enamel. The demineralized and remineralized groups with sodium fluoride and artificial saliva presented statistically lower results when compared to the other groups
Asunto(s)
Animales , Bovinos , Caries Dental , Esmalte DentalRESUMEN
The Frailty Syndrome is not synonymous with disability, but may be a precursor of etiological and physiological dysfunction, which affects mobility before causing reduced functional capacity, explaining conditions of weakness, weight loss, and abnormal gait. Study design: This is an analytical, observational, cross-sectional study. Objective: To verify the association of handgrip strength, gait speed, fear of falling, and falls with the level of frailty. Methods: Study consisting of 54 participants, aged 65 and older,enrolled in a health care and monitoring government program in the municipality of Uberaba, Minas Gerais, Brazil. The volunteers were assessed for frailty, non-frail group (NG), pre-frail group (PG), and frailgroup (FG) according to the Fried criteria, and based on the outcomes of handgrip strength, gait speed, fear of falling, and falls. An inferential descriptive statistical analysis followed, with Chi-square and Kruskall Wallistests performed by the Stata11.0 software. Results: In the comparative analysis between the groups studied there was statistical significance relative to handgrip strength (FG and NG), gait speed (NG andFG / NG and PG), and fear of falling (NG and FG). There was no significant difference between the levels of frailty and falls. Conclusions: Frailty is associated with reduced muscle strength, decreased gait speed,and greater fear of falling in elderly people of the community...
A síndrome de fragilidade não é sinônimo de incapacidade, mas pode ser um precursor fisiológico e etiológico de disfunção, que afeta a mobilidade antes de causar redução da capacidade funcional, explicando condições de fraqueza, perda de peso e alterações de marcha. Modelo do estudo: Estudo analítico, observacional e transversal. Objetivo: Verificar a associação da força de preensão palmar, velocidade da marcha, medo de cair e quedas com os níveis de fragilidade. Métodos: Estudo composto por 54 participantes com idade igual ou superior à 65 anos cadastrados em um programa governamental de atendimento e acompanhamento em saúde no município de Uberaba Minas Gerais.Os voluntários foram avaliados quanto à fragilidade (grupo não-frágil (GN), grupo pré-frágil (GP) e grupo frágil (GF), segundo os critérios de Fried e quanto aos desfechos força de preensão palmar, velocidade da marcha, medo de cair e quedas. Procedeu-se à análise estatística descritiva e inferencial com os testes Qui-quadrado e Kruskall-Wallis por meio do software Stata11.0. Resultados: Na análise de comparação entre os grupos estudados, houve significância estatística em relação à força de preensão palmar(GN e GF), velocidade da marcha (GN e GF, GN e GP) e medo de cair (GN e GF). Não houve significância entre os níveis de fragilidade e quedas. Conclusão: A fragilidade está associada à menor força muscular, diminuição da velocidade da marcha e maior medo de cair em idosos da comunidade...
Asunto(s)
Humanos , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Accidentes por Caídas , Envejecimiento , Fuerza Muscular , Fuerza de la Mano , Anciano Frágil , MarchaRESUMEN
OBJETIVO: Investigar as associações entre diversas medidas indicadoras do estado nutricional, a força muscular e as diferentes variáveis estabilométricas em uma amostra de idosas. MÉTODOS: Neste estudo exploratório de corte transversal, 108 idosas tiveram suas variáveis estabilométricas avaliadas através de uma plataforma de força, em duas condições experimentais: olhos abertos e olhos fechados. Verificaram-se as associações entre as variáveis explicativas: idade, massa corporal, estatura, índice de massa corporal, circunferência de quadril, circunferência de cintura, relação cintura/quadril, percentual de gordura corporal, massa gorda, massa magra, área muscular de braço corrigida, força isométrica voluntária máxima e diversas variáveis estabilométricas: amplitude anteroposterior, deslocamento da oscilação e área elíptica da superfície, dentre outras. RESULTADOS: Com exceção da estatura, todas as variáveis explicativas associaram-se significativamente com as variáveis estabilométricas. A regressão múltipla (forward) revelou que a circunferência de cintura e a força isométrica voluntária máxima foram as variáveis que mais influenciaram as variáveis estabilométricas, entretanto sem diferenças significativas entre as condições olhos abertos e olhos fechados. O percentual de gordura parece não sobrecarregar o sistema de controle postural. Na condição olhos abertos, a variável estabilométrica desvio--padrão médio-lateral foi a mais influenciada pelas variáveis explicativas. A circunferência de cintura foi respon-sável por 8,8% de toda variação do desvio-padrão médio-lateral e a força isométrica voluntária máxima contribuiu com 9,4% adicionais. CONCLUSÃO: Os resultados sugerem que a distribuição centrípeta de gordura corporal associada à diminuição da força muscular são as principais responsáveis pelas alterações estabilométricas em idosas.
OBJECTIVE: To investigate the association and the relative contribution of different measurements used as indicators of nutritional status and muscle strength with different stabilometric variables in a sample of elderly. METHODS: In this cross-sectional study and exploratory, stabilometry with the use of force platform was performed with 108 elderly women selected in two experimental conditions: eyes open and eyes closed. It was found associations between explanatory variables: age, body mass, height, body mass index, hip circumference, waist circumference, waist to hip ratio, percentage of body fat, fat mass, lean body mass, corrected arm muscle area, maximum voluntary isometric strength and the stabilometric several variables: anteroposterior amplitude, cop displacement and elliptical surface area, among others. RESULTS: The explanatory variables associated significantly with the stabilometric variables, except height. Multiple regression analysis (forward) revealed that waist circumference and the maximum voluntary isometric strength were the variables that most influenced stabilometric variables without major significant differences between the conditions of eyes open and eyes closed. The % body fat seems not to overload the system postural control sample of this study. The variable stabilometric mediolateral standard deviation (eyes open) was the most influenced by the explanatory variables. The waist circumference was responsible for 8.8% of all variation of mediolateral standard deviation and maximum voluntary isometric strenght contributed 9.4% additionally. CONCLUSION: The regression analysis suggests that the centripetal distribution of body fat associated with reduced muscle strength are responsible, partly, for stabilometric changes in elderly women.