Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 1038-1045, 2023.
Artículo en Chino | WPRIM | ID: wpr-998997

RESUMEN

ObjectiveTo summarize and analyze the clinical features and CT imaging findings of melioidosis pneumonia in order to increase awareness of this disease. MethodsA retrospective study was done on clinical and CT imaging data of 68 cases with melioidosis pneumonia diagnosed from January 1, 2012 to April 1, 2023. ResultsOf the 68 cases, 62 presented with acute infection and 6 chronic infection, 88.2% were male, 85.3% were native residents of Hainan, 85.3% were farmers, 77.9% had onset in summer and autumn, 66.2% had diabetes, 100% had fever as the first clinical symptom, and 88.2% were confirmed positive by blood culture. In most patients, white blood cell count, neutrophil ratio, C-reactive protein and calcitonin levels increased, while lymphocyte ratio decreased, but no statistical difference was found between acute and chronic infection groups (P > 0.05). Of the patients, 36.8% recovered, 42.6% got better, 11.8% patients became therapy-resistant and 8.8% died. CT image showed pathomorphological changes including nodules/masses, patchy ground-glass attenuation or large patchy consolidation or all of these at the same time. Acute and chronic infection groups had significant difference in pathomorphological changes (P = 0.01), but no statistical difference in other imaging findings. Moreover, 36.8% of the patients developed extrapulmonary infections, 8.8% of which multi-site abscess formation. ConclusionsMelioidosis Pneumonia should be considered if the patient is the sojourner from epidemic area, or has diabetes, high fever and rapid-developing disease, with additional presence of multiple inflammatory lesions in lung CT.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 645-652, 2023.
Artículo en Chino | WPRIM | ID: wpr-993138

RESUMEN

Objective:To explore the value of the deep learning image reconstruction (DLIR) algorithm in improving the CT image quality of abdominal phantoms under different radiation doses by comparing the DLIR algorithm with the conventional Adaptive Statistical Iterative Reconstruction-V (ASIR-V) technique.Methods:Two groups with tube voltages of 100 kV and 120 kV (also referred to as the 100 kV and 120 kV groups, respectively) were involved. Each group was further divided into six subgroups based on different volumetric CT dose indices (CTDI vol: 2, 4, 6, 8, 10 and 15 mGy). Subsequently, CT images based on the filtered back projection (FBP) algorithm were obtained and were then reconstructed using the ASIR-V algorithm with different weights (ASIR-V 50%, 80%, and 100%) and the DLIR algorithm with different levels (DLIR-L, M, and -H). As a result, 84 groups of images were obtained in total. Afterward, this study compared and analyzed the variations in CT values, noise, signal-to-noise ratios (SNRs), contrast-to-noise ratios (CNRs), and subjective scores of various parts in various CTDI vol subgroups under different reconstruction conditions. In addition, the subjective scores of the image quality were compared using the Kruskal-Wallis H test, while objective indices and radiation doses were compared through the univariate analysis of variance (ANOVA) and the paired t test. Results:Under the same tube voltage, there were statistically significant differences in the noise, SNRs, and CNRs of various parts in various CTDI vol subgroups under different reconstruction conditions ( F = 415.39, 315.30, P < 0.001), while there was no statistically significant difference in the noise, SNRs, and CNRs of images constructed using ASIR-V 50% and DLIR-L ( P > 0.05). Under different tube voltages, the subjective scores of both groups show statistically significant differences (100 kV group: H = 13.47, P = 0.036; 120 kV group: H = 12.99, P = 0.043). Moreover, two physicians offered consistent subjective scores, with Kappa values > 0.70. Among these images, DLIR-H images showed the highest subjective scores, followed by DLIR-M and ASIR-V 50% images, which had roughly consistent subjective scores. Moreover, the subjective scores of the 100 kV group were slightly higher than those of the 120 kV group. With the ASIR-V 50% images of the subgroup with a CTDI vol of 15 mGy as references, the DLIR-L, -M, and -H reduced radiation doses by more than 30%, 70% and 85%, respectively on the premise that diagnostic requirements were met. Conclusions:The DLIR algorithm can not only significantly reduce the image noise and improve the image quality, but also effectively decrease the radiation doses on the premise of meeting the diagnostic requirements. It is recommended that 100 kV tube voltage combined with a medium- or high-level DLIR algorithm should be applied to low-dose abdominal CT scans in clinical applications.

3.
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6): 466-472, 2023.
Artículo en Chino | WPRIM | ID: wpr-1005857

RESUMEN

【Objective】 To investigate the value of deep learning image reconstruction (DLIR) in improving image quality and reducing beam-hardening artifacts of low-dose abdominal CT. 【Methods】 For this study we prospectively enrolled 26 patients (14 males and 12 females, mean age of 60.35±10.89 years old) who underwent CT urography between October 2019 and June 2020. All the patients underwent conventional-dose unenhanced CT and contrast-enhanced CT in the portal venous phase (noise index of 10; volume computed tomographic dose index: 9.61 mGy) and low-dose CT in the excretory phase(noise index of 23; volume computed tomographic dose index: 2.95 mGy). CT images in the excretory phase were reconstructed using four algorithms: ASiR-V 50%, DLIR-L, DLIR-M, and DLIR-H. Repeated measures ANOVA and Kruskal-Wallis H test were used to compare the quantitative (skewness, noise, SNR, CNR) and qualitative (image quality, noise, beam-hardening artifacts) values among the four image groups. Post hoc comparisons were performed using Bonferroni test. 【Results】 In either quantitative or qualitative evaluation, the SNR, CNR, overall image quality score, and noise of DLIR images were similar or better than ASiR-V 50%. In addition, the SNR, CNR, and overall image quality scores increased as the DLIR weight increased, while the noise decreased. There was no statistically significant difference in the distortion artifacts (P=0.776) and contrast-induced beam-hardening artifacts (P=0.881) scores among these groups. 【Conclusion】 Compared with the ASiR-V 50% algorithm, DLIR algorithm, especially DLIR-M and DLIR-H, can significantly improve the image quality of low-dose abdominal CT, but has limitations in reducing contrast-induced beam-hardening artifacts.

4.
Cancer Research on Prevention and Treatment ; (12): 883-887, 2021.
Artículo en Chino | WPRIM | ID: wpr-988532

RESUMEN

Objective To investigate the imaging characteristics of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion. Methods We retrospectively analyzed the clinical and imaging data of five children with Xp11.2 tRCC confirmed by surgery and pathology in our hospital from January 2015 to December 2020. Four cases underwent CT plain scan and contrast-enhanced examination, and one case underwent MRI plain scan, contrast-enhanced examination and DWI examination. We observed and analyzed the location, size, shape, boundary, composition, enhancement pattern and degree, the relation with the renal hilum and adjacent large vessels, and the metastasis of the tumor. Results All cases were cortical-medullary type. Four cases were solid/cystic-solid lesions, iso- or slightly hyper-density on CT scans with calcification and necrosis, in which a few with bleeding or cystic lesions. Enhanced scanning primarily showed mild to moderate enhancement, and enhancement of pseudocapsule was seen during the delayed phase. One case was cystic lesion, the cystic fluid presented as hypo-density on CT, and T1 hypo-intensity and T2 hyper-intensity, as well as restricted diffusion on DWI. No enhancement was found in the cystic part after enhancement. There were irregular and thickened cystic wall and septum, and mural nodules on enhanced MRI. Conclusion Several characteristics of Xp11.2 tRCC in children could be drawn. Punctate and patchy calcifications in or around the solid/cystic-solid lesions and delayed "pseudocapsule sign" are typical. The possibility of Xp11.2 tRCC should be considered when there are irregular and thickened cystic wall and septum and the enhancement of mural nodules.

5.
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6): 763-768, 2021.
Artículo en Chino | WPRIM | ID: wpr-1011670

RESUMEN

【Objective】 To investigate the effects of 80 kVp combined with multi-model adaptive statistical iterative reconstruction algorithm (ASiR-V) on the image quality of CT angiography (CTA) of iliac artery in kidney transplantation candidates before operation. 【Methods】 Totally 50 kidney transplantation candidates underwent “one-stop” scanning combined CTA for coronary and iliac arteries were recruited consecutively. After the scanning, images were reconstructed with different ASiR-V levels on the iliac artery from 50% to 100% at a 10% interval, and 6 groups of images were obtained. We evaluated and compared all image qualities, DLP and CTDI in the patients’ examination were recorded, and the effective dose (ED) was calculated. 【Results】 All of the image quality objective scores of different ASiR-V levels on the iliac artery were above 3 points (3.32±0.24), and the average CT value was (344.30±74.53)HU. The ED received by the patient throughout the examination was (2.71±0.42)mSv. The image noise decreased while SNR and CNR increased monotonically as the ASiR-V levels increased, among which 80% ASiR-V image quality score was the highest with 3.41±0.26. 【Conclusion】 For patients who need to have both coronary and iliac arteries evaluated before kidney transplantation operation, low tube voltage (80 kVp) combined with 80% ASiR-V can obtain high-quality iliac artery images under the premise of reducing the ED dose, which can provide practical basis for further reducing the dose in personalized scanning scheme for such patients. It has good feasibility and clinical application value.

6.
Chinese Journal of General Surgery ; (12): 922-925, 2021.
Artículo en Chino | WPRIM | ID: wpr-933597

RESUMEN

Objectiv:To evaluate ultrasound, radionuclide imaging and CT in preoperative localization diagnosis of primary hyperparathyroidism (PHPT).Method:A total of 170 PHPT patients admitted to the hospital between Jan 1992 and Dec 2020 were analyzed retrospectively. The preoperative localization diagnostic efficacy of ultrasonography, radionuclide and CT alone and in combination was compared in groups.Results:The overall sensitivity of ultrasound, radionuclide and CT were 82.13%,80.43% and 75.74%. For normal positioned parathyroid adenoma: as for sensitivity of location diagnosis, ultrasound (86.67%) was higher than radionuclide (81.82%, P<0.05) and CT (80.59%, P<0.05), ultrasound/CT parallel test (94.70%, P<0.05) was higher than ultrasound alone. For specificity of location diagnosis, radionuclide (97.78%) was higher than ultrasound (91.62%) and CT (93.39%), both ultrasound/radionuclide series tests (99.00%, P<0.001)and ultrasound/CT series tests (96.94%, P<0.001) were higher than ultrasound alone. In case of ectopic parathyroid adenoma and parathyroid hyperplasia: the sensitivity and specificity of radionuclide seemed higher than ultrasound and CT. Conclusions:Ultrasound is the first choice for preoperative location diagnosis of PHPT. Ultrasound combined with radionuclide or CT can significantly improve the diagnostic efficiency of parathyroid lesions.

7.
Chinese Journal of Digestive Surgery ; (12): 913-919, 2021.
Artículo en Chino | WPRIM | ID: wpr-908453

RESUMEN

Objective:To investigate the computed tomography (CT) features of primary liver leiomyosarcoma (PHLMS).Methods:The retrospective and descriptive study was conducted. The clinical and imaging data of 10 patients with PHLMS who were admitted to 4 medical centers including 3 cases in Wenzhou Central Hospital, 3 cases in the Second Affiliated Hospital of Wenzhou Medical University, 2 cases in Wenzhou People's Hospital and 2 cases in Yueqing People's Hospital from January 2011 to December 2020 were collected. There were 5 males and 5 females, aged from 41 to 83 years, with a median age of 55 years. All 10 patients underwent abdominal CT examination. Observation indicators: (1) CT features; (2) treatment and pathological examination; (3) follow-up and survival. Follow-up using postoperative outpatient or inpatient examination to detect patient survival was conducted. Patients underwent imaging examination to detect tumor recurrence. Follow-up was up to December 2020. Measurement data with skewed distribution were represented as M (range). Count data were described as absolute numbers. Results:(1) CT features: results of CT examination showed that each of the 10 patients had only one single tumor, including 3 cases with tumor on the left lobe of liver and 7 cases with tumor on the right lobe of liver. The tumor diameter of the 10 patients was 8.0 cm(range, 4.5-13.5 cm). Results of plain CT scan of 10 patients showed that 7 cases had tumor in expansive growth as round or oval, with clear boundaries and the tumor parenchyma showing low-density signals and patchy lower density area can be seen in the center, and 3 cases had tumor in infiltrative growth as patchy, with unclear boundaries and the tumor parenchyma showing iso-density signals. The CT scan value of 10 patients was 40 HU(range, 23-47 HU). Results of enhanced CT scan at arterial phase of the 7 cases with tumor in expansive growth showed that 3 cases undergoing tumor parenchyma with uneven mild enhancement signals, 3 cases undergoing tumor parenchyma with uneven moderate enhancement signals and 1 case undergoing tumor parenchyma with uneven significant enhancement signal. The CT scan value of 7 cases was 68 HU(range, 62-88 HU). Results of enhanced CT scan at arterial phase of the 3 cases with tumor in infiltrative growth showed that the peripheral region had high signal than the central region. The CT scan value of 3 cases was 73 HU(range, 67-90 HU). Results of enhanced CT scan at portal vein phase in the 7 cases with tumor in expansive growth showed that the tumor parenchyma showing continuous and progressive mild and moderate enhancement with uneven density, and the CT scan value was 63 HU(range, 55-78 HU). Of the 7 cases, 3 cases showed the enhancement range of tumor parenchyma with the trend of fusion and filling, and 4 cases showed small patchy or nodular enhancement and grid like enhancement in the center and periphery of the tumor. Results of enhanced CT scan at portal vein phase in the 3 cases with tumor in infiltrative growth showed that the enhancement withdrew, the density was uneven, and the CT scan value was 58 HU(range, 50-62 HU). Results of enhanced CT scan at delayed phase in 10 patients showed that the enhancement in the tumor withdrew slowly, and the CT scan value was 53 HU(range, 50-60 HU). Of the 10 patients, 4 cases showed decreased density of enhanced nodules around the tumor and 6 cases showed partially fused and filled to the center of tumor with no enhancement in the necrotic part. (2) Treatment and pathological examination: all 10 patients underwent completed tumor resection successfully, and no metastasis was found in liver or the hilar region. Results of postoperative pathological examination showed that each of the 10 patients had only one single visible tumor with tumor diameter of 8.0 cm(range, 4.5?13.5 cm). Of the 10 patients, 7 cases had tumor with complete or incomplete pseudocapsule with clear boundary and 3 cases had tumor without pseudocapsule and the boundary was unclear. All 10 patients had tumor with hard parenchyma and the section was mostly gray and fish like. Among them, patchy or punctate necrosis was seen in 7 cases, small patchy or punctate hemorrhage was seen in 3 cases, and small patchy calcification was seen in 2 cases. Microscopically, the tumor tissue was crisscross, the tumor cells were in spindle shaped, the nuclei were in round, oval, blunt at both ends or in thin rod like, with obvious heteromorphism, large and deeply staining, and obviously division. Immunohistochemical staining showed positive staining of smooth muscle actin, desmin and vimentin. (3) Follow-up and survival: all 10 patients were followed up postoperatively for 6 to 130 months, with a median follow-up time of 55 months. The overall survival time of 10 patients were 10 to 120 months, with a median overall survival time of 46 months. Of the 10 patients, 2 cases died of tumor recurrence and distant metastasis 10 and 11 months after operation, respectively and 8 cases survived >12 months.Conclusions:Results of plain CT scan of PHLMS show clear or unclear cysts and solid masses with uneven density. Results of enhancement CT scan of PHLMS show persistent uneven enhancement in tumor parenchyma and the surrounding area.

8.
Chinese Journal of Interventional Imaging and Therapy ; (12): 421-424, 2020.
Artículo en Chino | WPRIM | ID: wpr-861953

RESUMEN

Objective: To observe the value of preoperative multi-slice spiral CT angiography (MSCTA) and intraoperative assisted ultrasound in application of laparoscopic kidney-preserving surgery for treating small renal cancer (tumor diameter ≤4 cm). Methods: A total of 85 patients with small kidney cancer underwent retroperitoneal laparoscopic nephron-sparing surgery, including 43 underwent preoperative MSCTA and intraoperative assisted ultrasound (observe group) and 42 underwent preoperative routine renal ultrasound and CT examination (control group). The relevant indicators were compared between the two groups. Results: Preoperative MSCTA findings of observe group were consistent with intraoperative findings. The operative time, intraoperative heat ischemia time, intraoperative blood loss and postoperative hospital stay in observe group were all less than those in control group (all P0.05), while the postoperative GFR of control group was lower than that before surgery (P=0.040). Conclusion: Preoperative MSCTA and intraoperative auxiliary ultrasound during retroperitoneal laparoscopic nephron-sparing surgery for patients with small renal carcinoma can reduce intraoperative blood loss and positive rate of resection margin, reserve as much nephrons as possible to promote the recovery of renal function.

9.
Chinese Journal of Interventional Imaging and Therapy ; (12): 561-564, 2020.
Artículo en Chino | WPRIM | ID: wpr-861931

RESUMEN

Objective To observe the value of renal artery plus renal vein CTA in preoperative evaluation on renal arteriovenous anatomy and tumor thrombi of massive renal carcinoma. Methods Renal artery + renal vein CTA obtained with 256-slice spiral CT of 56 patients with renal carcinoma confirmed by postoperative pathology were retrospectively analyzed, and the images were reconstructed. The anatomical situation of renal artery and renal vein, the location and type of tumor thrombi were observed and compared with surgical operation findings. Results All 56 patients had single tumor, located in the left kidney in 26 cases, while in the right kidney in 30 cases. The maximum diameter of tumor was 71-144 mm ([84.33±20.59]mm). There was no significant difference of the variation rate between the healthy side and the affected side of renal arteries nor veins (all P>0.05). CTA showed totally 117 tumor feeding arteries, while 118 tumor feeding arteries were found during operation, and the coincidence rate was 99.15% (117/118). CTA showed 69 draining veins, so did surgical operation, and the coincidence rate was 100% (69/69). CTA showed tumor thrombi infiltrating renal vein in 5 cases (5/56, 8.93%), infiltration of renal vein and inferior vena cava in 9 cases (9/56, 16.07%), including 5 cases of Mayo type 0, 3 cases of type , 4 cases of type Ⅱ, 2 cases of type III, whereas 42 cases (42/56, 75,00%) were found without infiltrating renal vein. Conclusion Preoperative renal artery plus renal vein CTA can accurately evaluate renal arteriovenous anatomy and location and type of tumor thrombi of renal mass renal carcinoma.

10.
Chinese Journal of Medical Imaging Technology ; (12): 391-395, 2020.
Artículo en Chino | WPRIM | ID: wpr-861082

RESUMEN

Objective: To explore whether vulnerable coronary plaques in HIV-infected patients are different with those in non-HIV-infected ones, and to analyze the relative risk factors. Methods: A total of 167 HIV-infected patients (HIV-infected group) and 185 non-HIV-infected patients(non-HIV-infected group) who underwent coronary CTA (CCTA) were collected. Vulnerable plaques were defined as those with two or more high-risk morphological features. The type, location and incidence of vulnerable coronary plaques were analyzed and compared between 2 groups, and the risk factors of vulnerable coronary plaques in HIV-infected patients were analyzed. Results: There was no significant difference of baseline clinical data between the two groups. The most common types of vulnerable coronary plaques in 2 groups were both low attenuation plaques+positive remodeling, most located in the proximal segment of left anterior descending artery (segment 6). The incidence of vulnerable coronary plaques ≥1 coronary segments in HIV-infected patients was higher than that in non-HIV-infected patients (34.73% vs 24.32%,P<0.05). Vulnerable coronary plaques in HIV-infected patients were independently correlated with the duration of antiretroviral therapy (ART) drug (OR=1.29, 95%CI [1.04,1.59], P=0.02). Conclusion: The incidence of vulnerable coronary plaques in HIV-infected patients was higher than that in non-HIV-infected patients. ART drug may be an independent risk factor for coronary plaque vulnerability in HIV-infected patients.

11.
Chinese Journal of Medical Imaging Technology ; (12): 1309-1313, 2020.
Artículo en Chino | WPRIM | ID: wpr-860904

RESUMEN

Objective: To investigate the feasibility of energy spectrum CT angiography (CTA) in distinguishing the components of atherosclerosis plaque in carotid artery, and to analyze the relationship of different type atherosclerosis plaque with cerebral infarction. Methods: Energy spectrum CTA and head MRI were performed on 60 patients with carotid artery stenosis detected with ultrasound. CT value and effective atomic number of plaque, fat, muscle and bone tissue were measured, respectively. The characteristic energy spectrum curve of average CT value in 40-140 keV single energy image were obtained, and slope of energy spectrum curve was calculated. Cerebral infarction was evaluated based on MRI results. According to the results of energy spectrum CTA, the plaques were divided into lipid plaque, lipid core-dominated mixed plaque, fibrous composites-dominated mixed plaque, fibrous plaque and calcified plaque. The lipid plaque and lipid/fiber mixed plaque were classified as unstable plaque, and the fibrous plaque and calcified plaque were classified as stable plaque. The differences of the slope of energy spectrum curve and effective atomic number in patients of each type plaques were compared. The incidences of cerebral infarction in patients with various types of plaques were correlated. Results: A total of 109 carotid plaques were enrolled, including 21 lipid plaque, 11 lipid core-dominated mixed plaque, 30 fibrous composites-dominated mixed plaque, 15 fibrous plaque and 32 calcified plaque. Statistical differences of the corresponding energy curve slope and effective atomic number wer found among different type plaques (F=1 494. 83, 2 108. 74, both P<0.01). Totally 19, 11, 19, 10 and 20 patients were found with lipid plaque, lipid core-dominated mixed plaque, fibrous composites-dominated mixed plaque, fibrous plaque and calcified plaque, among them MRI detected cerebral infarction in 13, 6, 7, 2 and 1 patient, and the incidence of cerebral infarction was 68.42% (13/19), 54.55% (6/11), 36.84% (7/19), 11.11% (1/9), and 0 (0/20), respectively. The incidence of cerebral infarction in all 60 patients was 45.00%(27/60, in those with unstable plaque or stable plaque was 53.06% (26/49) and 3.33% (1/30), respectively. Conclusion: Energy spectrum CTA could be used for detailed analysis on the components and types of carotid plaques. The more the lipid components of plaque, the worse its stability, and the higher the risk of cerebral infarction.

12.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 629-635, 2019.
Artículo en Chino | WPRIM | ID: wpr-817760

RESUMEN

@#【Objective】 To summarize the CT and MRI imaging features of gallbladder neuroendocrine tumor.【Methods】 CT and MRI data of 10 patients with gallbladder neuroendocrine tumors proven by surgical pathology between January 2010 and May 2018 were retrospectively analyzed. Among them,6 patients underwent CT examination,3 underwent MRI examination,and 1 patient underwent both CT and MRI examinations. The size,morphologic features and contrast enhancement pattern of gallbladder tumors,and the presence of liver metastasis,bile duct and perihepatic metastasis,lymph node metastasis,and the presence of gallbladder stone were assessed.【Results】Among these 10 cases of gallbladder neuroendocrine tumor,the largest dimension of tumors ranged from 39 mm to 120 mm. The tumors manifest? ed as a mass protruding into the lumen with a broad base adhering to the wall of the gallbladder. In 7 patients who had undergone CT examination,the tumors manifested as an irregular mass with soft tissue density on CT. In 4 patients who had undergone MRI,the tumors showed homogeneous iso-intense signal on T1-weightedimaging,heterogenous hyper-intense signal on T2- weighted imaging,and limited diffusion on diffusion- weighted imaging. All tumors in 10 patients showed moderate,heterogeneous and persistent enhancement. Eight patients had liver metastasis,among whom 7 had metastases in liver segments 4 and 5,and 1 had multiple metastases in other liver segments. Six patients had bile duct invasion and 3 had hilar fat invasion. Seven patients had lymph node metastasis. One patient had gallstone.【Conclusion】Gallbladder neuroendocrine tumor has certain characteristic CT and MRI findings,such as a large mass in gallbladder,which tends to invade adjacent liver parenchyma,and extend along gallbladder neck and gallbladder ducts,accompanied with hepatic portal and retroperitoneal lymph node metastasis,and hilar fat invasion.

13.
Chinese Journal of Radiological Medicine and Protection ; (12): 155-160, 2019.
Artículo en Chino | WPRIM | ID: wpr-734333

RESUMEN

Objective To assess the influence on radiation dose and image quality of bronchial artery CT angiography for hemoptysis patients with high heart rate and free respiratory with single-cardiac dynamic volumetric scanning using 320-row CT.Methods During October 2016 and May 2017,totally 151 hemoptysis patients with heart rate ≥ 65 bmp and free-breathing were scanned for bronchial artery imaging with prospective ECG-gating 320-detector row dynamic volume CT.The patients were randomly divided into two groups,group A(81 cases) and group B(70 cases).Default multi-cardiac cycle scanning style was used for group A to generate multi-sector images A 1 which were reconstructed corresponding single-sector images A2.Single-cardiac periodic scanning was used to get single-sector images for group B.The effective doses (E) of two scanning types,the quantitative parameters of image quality [vascular CT value,image noise (SD),signal-to-noise ratio (SNR),contrast-to-noise ratio (CNR)] and subjective scoring of group B and A1,A2 were compared.The detection accuracy of the systemic artery-pulmonary circulation shunts was evaluated by ROC curve against digital subtraction angiography (DSA).The measurement data was analyzed by independent sample t test while the grade data was tested by independent sample nonparametric test.Results The median value of radiation dose in group B was significantly lower than that of group A (1.42 mSv vs.3.06 mSv,Z=-8.724,P<0.05).There were no statistically significant differences in quantitative parameters and subjective scoring points of image quality between group B and group A2 (P> 0.05).The median subjective scoring points of group B was 4,which was better than that of group A1 (Z =-10.584,P< 0.05).The differences of SD,SNR,CNR betweengroup B and group A1 were statistically significant(t =-0.983,7.898,7.695,P<0.05),and group B had higher SD,SNR and CNR.There was no significant difference in the mean CT values of the aorta and pulmonary artery between the two groups (P > 0.05).The detection accuracy of the systemic arterypulmonary circulation shunts was moderately high in group B and group A2.The area under the ROC curve (AUC) was 0.891 and 0.864,respectively (Z=7.210,7.430,P<0.05).The accuracy of group A1 was poor.The area under the ROC curve was 0.626 (Z=2.434,P<0.05).The sensitivity of group B and groupA2 were 80% and 76.2%,respectively (P<0.05),and 28.6% of group A1 (P<0.05).Conclusions The 320-row single-cardiac periodic dynamic volume CT can effectively improve the image quality and the detection accuracy of the systemic-pulmonary circulation on CT,and reduce the radiation dose of the bronchial artery CT angiography.

14.
Chinese Journal of Clinical Oncology ; (24): 669-672, 2019.
Artículo en Chino | WPRIM | ID: wpr-754481

RESUMEN

Objective: To explore the clinicopathological features and the diagnostic value of the CT scan in multilocular cystic renal neoplasm of low malignant potential (MCRNLMP) and cystic nephroma (CN). Methods: The clinical data of 12 patients with CN and 20 patients with MCRNLMP, confirmed by pathology at the Renmin Hospital of Wuhan University and Jingzhou Central Hospital from Janu-ary 2000 to March 2019, were retrospectively analyzed. The receiver operating characteristic (ROC) curves were used to analyze the feature of contrast-enhanced CT images of the tumors, and the immunophenotypes of the tumors were observed by immunohisto-chemistry. Results: There were statistically significant differences between MCRNLMP and CN in terms of thickness of the cyst wall and partition, number of soft-tissue enhancing masses, peak intensity of enhancement, and the Bosniak classification (P<0.05). Based on ROC curve analyses, when the thickness of the capsule wall and partition was greater than 2.25mm, the number of enhanced high-density lesions was greater than 1, and the peaking intensity of fortification was above the moderate level in the diagnosis of CRNLMP. The areas under the curve of the three indexes were 0.879, 0.800 and 0.838, which can be used as the best diagnostic criterion for MCRNLMP. Immunophenotyping revealed that MCRNLMP characteristically expressed the renal cell carcinoma (RCC) marker, and CN characteristically expressed the estrogen receptor(ER) and progesterone receptor(PR). Conclusions: The cyst wall and septal thickness, number of soft-tissue enhancing masses, and peak intensity of enhancement show a higher diagnostic value in differentiating MCRN-LMP and CN. The precise diagnosis relies on the pathological and immunohistochemical examination.

15.
Chinese Journal of Endocrine Surgery ; (6): 218-222, 2018.
Artículo en Chino | WPRIM | ID: wpr-695551

RESUMEN

Objective To investigate MSCT features of the intraductal papillary mucinous tumor of the pancreas.Methods The CT findings of 40 cases of intraductal papillary mucinous tumors confirmed by pathology were retrospectively analyzed,and the location,size,shape,edge and enhancement of the tumor were observed.Results Malignant (n=8):all of them were mainly pancreatic duct type,including 6 cases in the head of pancreas and 2 cases in the tail.All of them were multi-room,with 7 cases of cystic wall nodules and 7 cases of uneven septum thickening.The diameter of tumor cystic lesion was(41.0±0.5)mm on average,and the widest diameter of the dilated pancreatic duct was (6.9±1.0) mm.The cystic wall,wall nodule and interval were mild and moderate enhancement in the arterial phase,and continuous strengthening in the portal and delayed phases.Borderline(n=15):8 cases of main pancreatic duct type,1 case of branch pancreatic duct type,and 6 cases of mixed type.There were 10 cases in the head of the pancreas and 5 in the tail of the pancreas.There were 10 cases of multi room in the lesion,and the CT findings were composed of multiple clusters of small cystic lesions,with 3 cases of tuberous nodules on the cyst wall and 4 cases of irregular thickening of the cysts.5 cases were single room type,with capsule wall smooth and whole.The diameter of tumor cystic lesion was (28.0±0.5) mm on average,and the maximum diameter of the dilated pancreatic duct was (5.2±0.3) mm.The cystic wall and interval were mild and moderate enhancement in the arterial phase,and mild and continuous strengthening in the portal and delayed phases.Benign (n=17):1 case of main pancreatic duct type,10 cases of pancreatic duct type and 6 cases of mixed type;There were 12 cases in the head of the pancreas and 5 in the tail.All of them were single cystic type,and the cyst wall was smooth.The diameter of the tumor cystic lesion was (26±0.3) mm on average and the maximum diameter of the dilated pancreatic duct was (3.5±0.4) mm.There was no enhancement of the cystic wall in the arterial phase,mild enhancement in the portal phase,and mild continuous delayed phase in 2 cases,no enhancement in 15 cases.Conclusion MSCT expression of the intraductal papillary mucinous tumor of the pancreas has its characteristic features,which is helpful for the diagnosis and treatment of the disease.

16.
Chinese Journal of Endocrine Surgery ; (6): 43-46, 2018.
Artículo en Chino | WPRIM | ID: wpr-695504

RESUMEN

Objective To investigate the diagnostic significance of CT in thyroid benign solitary coarse calcification nodules (BCCN).Methods A total of 56 BCCN confirmed by surgical pathology in 55 patients were evaluated,and they were compared with 33 papillary thyroid carcinoma (PTC) in 32 patients.The distribution differences of the average CT values and the maximum CT values in BCCN and PTC were observed.The optimal thresholds of the average CT values and the maximum CT values in BCCN and PTC were established by re ceiver operating characteristic(ROC) curve analysis.Results The average CT values in BCCN and PTC were significantly different (t=4.992,P=0.000).The ROC area under curve (AUC) was 0.757 (95% confidence interval 0.0657-0.0857).When the critical value was 743.4 Hu,Youden index was the largest and the sensitivity and specificity was 48.2% and 93.9%,respectively.When the critical value was 891.1 Hu,the sensitivity and specificity was 21.4% and 100%,respectively.The maximum CT values in BCCN and PTC were significantly different (t=5.029,P=0.000).The ROC AUC was 0.775 (95% confidence interval 0.0681-0.0869).When the critical value was 1201.5 Hu,Youden index was the largest and the sensitivity and specificity was 51.7% and 91.0%,respectively.When the critical value was 1373.5 Hu,the sensitivity and specificity was 42.9% and 100%,respectively.Conclusions CT value is of great significance to the diagnosis of BCCN and has high specificity.Compared with the average CT value,the maximum CT value has a relatively higher sensitivity,providing an important base for reducing unnecessary surgical trauma.

17.
Chinese Journal of Radiological Medicine and Protection ; (12): 311-316, 2018.
Artículo en Chino | WPRIM | ID: wpr-708061

RESUMEN

Objective To evaluate the feasibility of adaptive statistical iterative reconstruction-V (ASIR-V) to improve image quality in low-dose CT colonography.Methods A series of thirty artificial polyps were established by ligation in an isolated segment of porcine colon.Volume data was acquired on Revolution CT scanner (GE,USA) with High Definition scan mode and different scan parameter combinations:120 kVp with different mAs (10,30,50,70,90,100,120,140,160,180,200,220,240,260,respectively).Images were reconstructed with six different ASIR-V levels of 0 (filtered back projection,FBP),10%,30%,50%,70% and 90%.Two radiologists were blinded to measure and analyze the objective data independently,including image noise (SD),signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR).The kappa test was used to assess interobserver agreement in subjective image quality score.ICC test was used to examine the consistency of the measurements between two observers.SD,SNR,CNR were performed for statistical analysis in different tube current and different levels of ASIR-V using variance analysis (ANOVA).Results Interobserver agreement for subjective image quality score was good with a kappa value of 0.683.The variation of the tube current(r =0.734,P =0.000) and ASIR-V level(r =0.220,P =0.044) is related to the subjective score of image quality.Under the condition of the same tube current,image quality score of 50% ASIR-V reconstruction was the highest.Two objective data consistency is good.The differences of image noise (F =423.58,P < 0.05),SNRs(F =124.26,P < 0.05) and CNRs (F =1 030.17,P < 0.05) of different tube current and different levels of ASIR-V reconstruction were statistically significant.In the same tube current,with increased levels of ASIR-V,image noise reduced,CNRs increased.Only in 10,120,140,160,220,240,260 mA,the differences of SNRs were statistically significant(F =8.75-31.36,P < 0.05).For the same level of ASIR-V reconstruction,with the increase of tube current,the image noise decreased,SNR and CNR increased gradually.Conclusions In the CT colonography,the application of ASIR-V algorithm can significantly reduce the noise and enhance the image contrast noise ratio and improve image quality.ASIR-V algorithm with 50% has better performance in reducing CT image noise.

18.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 10-13, 2018.
Artículo en Chino | WPRIM | ID: wpr-701644

RESUMEN

Objective To analyze the CT manifestations of gastrointestinal stromal tumors(GIST),and compared with the pathological results,in order to improve the value of CT in clinical diagnosis of GIST.Methods 256 slice spiral CT manifestations of 35 cases with GIST confirmed by surgery and pathology were analyzed retrospectively.Results 30 cases with GIST tumors were located in the stomach,duodenum in 2 cases,ileum in 2 cases,1 case with multiple tumors (located in mesentery,retinal).The tumor size ranged from 1.0 to 11.2 cm.11 cases of lumps showed soft tissue mass,24 cases showed uneven density with cystic and necrosis,including 10 cases with ulceration in surface.There were 5 cases with hemorrhage,2 cases with scattered calcification.After enhancement scan,11 cases of tumors were homogeneous enhancement and 24 cases showed uneven enhancement.The solid composition was shown more rich blood supply,especially in the venous phase.There were 9 cases out of the digestive tract,22 cases in the digestive tract,4 cases were mixed growth.There were 35 cases with CD117 positive expression by immunohistochemistry,34 cases with CD34 positive expression.After postoperative pathological risk assessment,there were 21 cases with low risk malignant tumor,moderate malignant tumor in 7 cases,highly malignant tumor in 7 cases.Conclusion 256 layers spiral CT scan can accurately offer the morphology of gastrointestinal stromal tumor,location,size and internal structure,and evaluate the risk level of tumor,it is helpful for clinical preoperative treatment,and determination of the prognosis.

19.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 1995-1997, 2017.
Artículo en Chino | WPRIM | ID: wpr-619086

RESUMEN

Objective To analyze the plain and enhanced features of multiple spiral CT in primary splenic tumors,and to evaluate the diagnostic value.Methods The spiral CT findings of 29 cases of splenic primary tumors proved by operation or biopsy were retrospectively analyzed.Results 23 cases of benign tumors (9 cases of splenic cyst,7 cases of hemangioma,3 cases of lymphangioma,2 cases of myofibroblastic tumor,hamartoma in 2 cases),clinical manifestations of mild abdominal discomfort or no symptoms;CT scan for spleen in single or multiple low density or mixed density mass.Hemangioma,wrong structure can show the tumor calcification spots,hamartoma with calcification or fat density.CT enhancement,no enhancement of splenic cyst,hemangioma and delayed enhancement,center filling;lymphangioma without slight strengthening or interval,myofibroblastic tumor or hamartoma to strengthen the characteristic of diversity.6 cases of malignant tumors (3 cases of lymphangioma,2 cases of lymphoma,1 case of malignant fibrous histiocytoma of angiosarcoma),malignant tumors had abdominal pain,weight loss and other symptoms,CT scan,spleen enlargement,mass was larger,the boundary was not clear,less calcification,can strengthen the CT,tumor metastasis;lymph enhanced slightly,angiosarcoma delayed enhancement,uneven enhancement of malignant fibrous histiocytoma.Conclusion Multi slice spiral CT scanning combined with enhancement has a high diagnostic value for primary splenic tumors.

20.
Chinese Journal of Hepatobiliary Surgery ; (12): 296-299, 2017.
Artículo en Chino | WPRIM | ID: wpr-618705

RESUMEN

Objective To investigate radiological features on computed tomography (CT) in the di agnosis of portal venous and intestinal wall gas in patients with ischemic bowel disease.Methods The clinic-pathological data of 17 patients with portal venous and intestinal gas associated with ischemic bowel diseases from Wenzhou People's Hospital (n =6),Yueqing People's Hospital (n =5),Shanghai Xuhui Dahua Hospital (n =3) and the Second Affiliated Hospital of Wenzhou Medical University (n =3) from January 2013 to October 2016 were analysed retrospectively.All the patients have been fasting for 8 h prior to CT scans.Enhanced CT study was performed following routine CT with no abdominal pressure for breath less scanting.Portal venous gas,intestinal wall gas,intestinal thickness and density,mesentery thickness,celiac effusion,and severity of intestinal wall enhancement were recorded.Results All the 17 patients ex perienced abdominal distension and pain.Additionally,nausea and vomiting was observed in 9 patients,di arrhea in 7,melena in 7,periumbilical tenderness in 11 and rebound tenderness in 8.CT scans of these 17 patients showed portal venous gas,including massiveprune-tree signs of hepatic vein and portal vein (n =11) and scanty gas shadows in distal hepatic vein (n =6).Intestinal gas sign was determined in all these patients (n =17),including single bubble shadow (n =8),multiple bubble shadow (n =7),and band-shaped bubble (n =2).Furthermore,CT study indicated extensive intestinal wall thickening with edema (n =13),predominate luminal extension of thinner bowels (n =4),scanty celiac effusion (n =3).Enhanced CT scans demonstrated 8 patients with decreased enhancement of intestinal wall and mesentery with diseases,target and halo signs observed in enhanced scans.Conclusions Portal venous and intestinal wall gas may demonstrate distinctive CT imaging.CT study could have superior sensitivity and spe cialty in clinical diagnoses of ischemic bowel diseases.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA