Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Arq. bras. cardiol ; 114(4): 638-644, Abr. 2020. tab, graf
Artículo en Inglés, Portugués | LILACS, SES-SP | ID: biblio-1131195

RESUMEN

Abstract Background: The practice of screening for complications has provided high survival rates among heart transplantation (HTx) recipients. Objectives: Our aim was to assess whether changes in left ventricular (LV) and right ventricular (RV) global longitudinal strain (GLS) are associated with cellular rejection. Methods: Patients who underwent HTx in a single center (2015 - 2016; n = 19) were included in this retrospective analysis. A total of 170 biopsies and corresponding echocardiograms were evaluated. Comparisons were made among biopsy/echocardiogram pairs with no or mild (0R/1R) evidence of cellular rejection (n = 130 and n = 25, respectively) and those with moderate (2R) rejection episodes (n=15). P-values < 0.05 were considered statistically significant Results: Most patients were women (58%) with 48 ± 12.4 years of age. Compared with echocardiograms from patients with 0R/1R rejection, those of patients with 2R biopsies showed greater LV posterior wall thickness, E/e' ratio, and E/A ratio compared to the other group. LV systolic function did not differ between groups. On the other hand, RV systolic function was more reduced in the 2R group than in the other group, when evaluated by TAPSE, S wave, and RV fractional area change (all p < 0.05). Furthermore, RV GLS (−23.0 ± 4.4% in the 0R/1R group vs. −20.6 ± 4.9% in the 2R group, p = 0.038) was more reduced in the 2R group than in the 0R/1R group. Conclusion: In HTx recipients, moderate acute cellular rejection is associated with RV systolic dysfunction as evaluated by RV strain, as well as by conventional echocardiographic parameters. Several echocardiographic parameters may be used to screen for cellular rejection.


Resumo Fundamento: A prática de triagem para complicações tem proporcionado altas taxas de sobrevida entre pacientes que receberam transplante cardíaco (TC). Objetivos: Visamos avaliar se alterações no strain longitudinal global (SLG) do ventrículo esquerdo (VE) e do ventrículo direito (VD) estão associadas à rejeição celular. Métodos: Pacientes que foram submetidos à TC em um único centro (2015 - 2016; n = 19) foram incluídos nesta análise retrospectiva. Foram avaliados um total de 170 biópsias com ecocardiogramas correspondentes. Foram realizadas comparações entre pares de biópsia/ecocardiograma com nenhuma ou leve (0R/1R) evidência de rejeição celular (n = 130 e n = 25, respectivamente) e aqueles com episódios de rejeição moderada (2R) (n = 15). Foram considerados estatisticamente significativos os valores de p < 0,05. Resultados: A maioria dos pacientes eram mulheres (58%) com idade média de 48 ± 12,4 anos. Em comparação com os ecocardiogramas dos pacientes com rejeição 0R/1R, os pacientes com biópsias 2R apresentaram maior espessura da parede posterior do VE, relação E/e' e relação E/A, em comparação com o outro grupo. A função sistólica do VE não diferiu entre os grupos. Por outro lado, a função sistólica do VD foi reduzida no grupo 2R em comparação ao outro grupo, quando avaliada por TAPSE, onda S e variação fracional da área do VD. Adicionalmente, SLG VD (−22,97 ± 4,4% no grupo 0R/1R vs. −20,6 ± 4,9% no grupo 2R, p = 0,038) foi reduzido no grupo 2R, em comparação com o grupo 0R/1R. Conclusão: Em pacientes de TC, rejeição celular aguda moderada está associada à disfunção sistólica do VD, avaliado pelo strain do VD, bem como por parâmetros ecocardiográficos convencionais. Vários parâmetros ecocardiográficos podem ser utilizados para realizar triagem para rejeição celular.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Trasplante de Corazón , Disfunción Ventricular Derecha/cirugía , Ecocardiografía , Estudios Retrospectivos , Función Ventricular Derecha , Disfunción Ventricular Izquierda , Rechazo de Injerto , Ventrículos Cardíacos , Persona de Mediana Edad
2.
Rev. Soc. Bras. Clín. Méd ; 17(3): 147-152, jul.-set. 2019.
Artículo en Portugués | LILACS | ID: biblio-1284214

RESUMEN

O tromboembolismo pulmonar é um grave problema de saúde pública devido ao subdiagnóstico e às elevadas morbidade e mortalidade. Quando a embolia pulmonar é maciça com repercussão hemodinâmica importante e a terapia adequada não ocorre nas primeiras horas, a mortalidade é superior a 85%. Na suspeita clínica de tromboembolismo pulmonar, a avaliação ecocardiográfica pode ter papel fundamental na avaliação da mobilidade e da estrutura do ventrículo direito, presença de hipertensão pulmonar e documentação da presença de trombo. A detecção ecocardiográfica de trombo móvel nas câmaras cardíacas direitas permite identificar um grupo de pacientes de alto risco, com mortalidade muito elevada, quando comparada ao tromboembolismo pulmonar em geral. Além da terapia clínica clássica, com heparinas e trombolíticos, as terapêuticas endovascular e cirúrgica devem ser consideradas e podem contribuir para o prognóstico desses pacientes. Relata-se um caso de uma paciente de 33 anos de idade admitida em uma unidade de emergência da no 8o dia de pós-operatório de apendicectomia, com queixas de dor torácica e dispneia de início súbito. Ecocardiograma transtorácico evidenciou presença de trombo serpiginoso solto em átrio direito, que ocluía intermitentemente a valva tricúspide durante o ciclo cardíaco. Diante das características ecocardiográficas atípicas do trombo e da significativa chance de embolização maciça, optou-se por intervenção cirúrgica de emergência.


Pulmonary thromboembolism is a serious public health problem due to misdiagnosis and high morbidity and mortality. When pulmonary embolism is massive with important hemodynamic repercussion, and the appropriate therapy does not take place in the early hours, mortality is higher than 85%. If there is clinical suspicion of pulmonary thromboembolism, an echocardiographic evaluation may have a key role in the evaluation of mobility and structure of the right ventricle, presence of pulmonary hypertension, and documentation of the presence of thrombus. Echocardiographic detection of mobile thrombus in right cardiac chambers allows the identification of a group of high-risk patients with very high mortality when compared to pulmonary thromboembolism in general . In addition to the classical clinical therapy with heparins and thrombolytics, endovascular and surgical therapy should be considered and may contribute to these patients' prognosis. A case is reported of a 33-year-old female patient admitted to an Emergency Unit at 8th postoperative day (POD) of appendectomy, with complaints of chest pain and dyspnea of sudden onset. Transthoracic echocardiography showed the presence of a floating serpiginous thrombus in the right atrium, which intermittently occluded the tricuspid valve during the cardiac cycle. Due to the atypical echocardiographic features of the thrombus, and significant chance of massive embolization, an emergency surgery was chosen.


Asunto(s)
Humanos , Femenino , Adulto , Embolia Pulmonar/diagnóstico por imagen , Ecocardiografía , Disfunción Ventricular Derecha/diagnóstico por imagen , Embolia Pulmonar/cirugía , Embolia Pulmonar/complicaciones , Embolia Pulmonar/tratamiento farmacológico , Taquicardia/etiología , Vasoconstrictores/uso terapéutico , Warfarina/uso terapéutico , Dolor en el Pecho/etiología , Radiografía , Norepinefrina/uso terapéutico , Enoxaparina/uso terapéutico , Disfunción Ventricular Derecha/cirugía , Disfunción Ventricular Derecha/complicaciones , Disfunción Ventricular Derecha/tratamiento farmacológico , Disnea/etiología , Electroencefalografía , Taquipnea/etiología , Índice de Perfusión , Hipotensión/etiología , Hipoxia/etiología , Anticoagulantes/uso terapéutico
6.
Ann Card Anaesth ; 2014 Jan; 17(1): 59-61
Artículo en Inglés | IMSEAR | ID: sea-149696

RESUMEN

Improved survival from congenital heart disease has led to an increasing need for complex reoperation by reentrant sternotomy. Peripheral cannulation and initiation of cardiopulmonary bypass prior to sternotomy to avoid the risk of cardiac injury and massive hemorrhage is an option in adults and larger children, but femoral vessel size precludes this strategy in infants. We describe the management of a high‑risk reentry sternotomy in an infant for repair of a giant pseudoaneurysm after prior homograft repair of tetralogy of Fallot, using surgical dissection for suprasternal cannulation of the innominate artery and subxyphoid cannulation of the inferior vena cava.


Asunto(s)
Anestesia/métodos , Aneurisma Falso/cirugía , Cateterismo Cardíaco , Puente Cardiopulmonar , Femenino , Cardiopatías Congénitas/cirugía , Ventrículos Cardíacos/cirugía , Humanos , Lactante , Reoperación , Esternotomía/métodos , Tetralogía de Fallot/métodos , Resultado del Tratamiento , Disfunción Ventricular Derecha/cirugía
7.
Rev. bras. cir. cardiovasc ; 27(4): 552-561, out.-dez. 2012. ilus, tab
Artículo en Portugués | LILACS | ID: lil-668117

RESUMEN

OBJETIVO: Este estudo avaliou o desempenho hemodinâmico e as alterações miocárdicas decorrentes do emprego de dispositivos de assistência ventricular esquerda (DAVE), associado ou não à descompressão do ventrículo direito por meio de derivação cavo-pulmonar, sendo esses achados comparados ao emprego de assistência circulatória biventricular. MÉTODOS: Vinte e um suínos foram submetidos à indução de insuficiência cardíaca através de fibrilação ventricular, sendo a atividade circulatória mantida por DAVE durante 180 minutos. No grupo controle, foi apenas implantado o DAVE. No grupo derivação, além do DAVE foi realizada cirurgia de derivação cavo-pulmonar. No grupo biventricular, foi instituída assistência biventricular. Foram monitoradas as pressões intracavitárias por 3 horas de assistência e amostras do endocárdio dos dois ventrículos foram coletadas e analisadas à microscopia óptica e eletrônica. RESULTADOS: O lactato sérico foi significativamente menor no grupo biventricular (P=0,014). A diferença observada entre o fluxo do DAVE nos grupos derivação e controle (+55±14 ml/kg/min, P=0,072) não foi significativa, enquanto que o fluxo no grupo biventricular foi significativamente maior (+93±17 ml/kg/min, P=0,012) e se manteve estável durante o experimento. A pressão arterial média (PAM) se manteve constante apenas no grupo biventricular (P<0,001), que também apresentou diminuição significativa das pressões em câmaras direitas. Na análise ultraestrutural, notou-se menor presença edema miocárdico no ventrículo direito no grupo biventricular (P=0,017). CONCLUSÃO: Os resultados apresentados demonstram que o desempenho hemodinâmico da assistência ventricular esquerda associada à derivação cavo-pulmonar, neste modelo experimental, não foi superior ao observado com a assistência de ventrículo esquerdo isolada e não substituiu a assistência biventricular de maneira efetiva.


OBJECTIVE: Right ventricular (RV) failure during left ventricular assist device (LVAD) support can result in severe hemodynamic compromise with high mortality. This study investigated the acute effects of cavo-pulmonary anastomosis on LVAD performance and RV myocardial compromise in comparison with biventricular circulatory support, in a model of biventricular failure. METHODS: LVAD support was performed by centrifugal pump in 21 pigs with severe biventricular failure obtained by FV induction. Animals were randomized to be submitted to cavo-pulmonary anastomosis, to biventricular circulatory support or to control group. They were maintained under circulatory support and hemodynamic monitoring for 3h. Venous lactate and cytokines serum levels were also obtained. Endocardium samples were analyzed by electronic microscopy. RESULTS: FV maintenance was responsible for acute LVAD impairment after 180 min in the control group. cavo-pulmonary anastomosis resulted in non-significant improvement of LVAD pump flow in relation to control group (+55±14 ml/kg/min, P=0.072), while animals under biventricular support maintained higher LVAD flow (+93±17 ml/kg/min, P=0.012). Mean arterial pressure remained constant only in biventricular group (P<0.001), which also presented decrease of right atrial and ventricular pressures. Similar increases in lactate and cytokines levels were observed in the three groups. Ultra-structural analysis documented low levels of myocardial swelling in the biventricular group (P=0.017). CONCLUSION: The concomitant use of cavo-pulmonary anastomosis during LVAD support in a pig model of severe biventricular failure resulted in non-significant improvement of hemodynamic performance and it did not effectively replace the use of biventricular support.


Asunto(s)
Animales , Puente Cardíaco Derecho/métodos , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/ultraestructura , Corazón Auxiliar/efectos adversos , Hemodinámica/fisiología , Disfunción Ventricular Derecha/fisiopatología , Citocinas/sangre , Modelos Animales de Enfermedad , Insuficiencia Cardíaca/sangre , Ácido Láctico/sangre , Distribución Aleatoria , Estadísticas no Paramétricas , Porcinos , Disfunción Ventricular Derecha/cirugía
8.
Rev. bras. cir. cardiovasc ; 26(3): 504-507, jul.-set. 2011.
Artículo en Portugués | LILACS | ID: lil-624535

RESUMEN

Cistos pericárdicos são raros, comumente congênitos, com localização mais frequente no ângulo cardiofrênico direito. O diagnóstico é suspeitado pela radiografia de tórax anormal. O presente relato descreve um caso de cisto pericárdico com aspecto radiográfico atípico, em um paciente atleta, manifestando-se clinicamente com sintomas de insuficiência ventricular direita. O diagnóstico foi sugerido pelo ecocardiograma transesofágico e confirmado pelo estudo anatomopatológico.


Pericardial cysts are rare, usually congenital. Cysts frequently occur in the right cardiophrenic angle and their diagnosis is usually suspected after an abnormal chest X ray. The present case report shows a case of pericardial cyst with atypical radiographic aspect in an athletic patient who presented clinical with symptoms of right ventricular failure. The diagnosis was suggested by echocardiogram and subsequently was confirmed by pathologic examination.


Asunto(s)
Adulto , Humanos , Masculino , Quiste Mediastínico/complicaciones , Disfunción Ventricular Derecha/etiología , Levantamiento de Peso/lesiones , Constricción Patológica/etiología , Constricción Patológica/cirugía , Quiste Mediastínico/cirugía , Disfunción Ventricular Derecha/cirugía
10.
Rev. bras. cir. cardiovasc ; 23(2): 197-203, abr.-jun. 2008. ilus
Artículo en Inglés, Portugués | LILACS | ID: lil-492971

RESUMEN

OBJETIVO: Descrever a técnica de preparo e a evolução ecocardiográfica das cúspides de homoenxerto decelularizado utilizadas em pacientes com tetralogia de Fallot. MÉTODOS: No período de março de 2005 a agosto de 2007, 15 pacientes foram submetidos ao implante deste tipo de enxerto e foram acompanhados clinicamente e com ecocardiograma para avaliar o resultado morfofuncional dos enxertos. RESULTADOS: O acompanhamento médio foi de 12,7 meses (1-25 meses). A análise ecocardiográfica em médio prazo revelou: insuficiência pulmonar leve em nove (60 por cento) pacientes, moderada em três (20 por cento) e importante em três (20 por cento); a função sistólica do ventrículo direito esteve preservada em 13 (86,7 por cento) pacientes e com disfunção leve em dois (13,3 por cento); 11 (73,4 por cento) pacientes não apresentaram gradientes na via de saída do ventrículo direito (VD), e em quatro (26,6 por cento) pacientes evidenciou-se a presença de estenose leve; a mobilidade da cúspide foi normal em todos os pacientes; não houve espessamento maior de 1,5mm nas cúspides analisadas; não se detectou nenhuma calcificação nas cúspides. Catorze (93,3 por cento) pacientes apresentaram Z score entre -1 e 0,7 e um (6,7 por cento) paciente apresentou anel pulmonar com Z score de + 2,5. CONCLUSÃO: O retalho de homoenxerto decelularizado parece ser uma boa opção para a ampliação da via de saída do VD nos pacientes submetidos à correção total da tetralogia de Fallot em médio prazo.


OBJECTIVE: To describe the technique of implantation and to show the echocardiographic follow-up of the decellularized cusps allografts used in patients with tetralogy of Fallot. METHODS: Fifteen patients underwent this implantation between March 2005 and August 2007 and they were clinically followed-up. An echocardiogram was performed to evaluate the morphofunctional result of the allografts. RESULTS: The mean follow-up was 12.7 months (1-25 months). The echocardiography results showed that pulmonary insufficiency was mild in nine (60 percent) patients, moderate in three (20 percent) patients, and severe in three (20 percent) patients. The results also showed that the systolic right ventricle function was normal in 13 (86.7 percent) and that there was mild dysfunction in two (13.3 percent). Eleven (73.4 percent) patients did not present any gradient in the right ventricular outflow tract and four (26.6 percent) presented mild stenosis. The mobility of the cusps were normal in all cases and there was no thickness larger than 1,5mm. There was no calcification; 14 patients (93,3 percent) presented Z score between -1 and 0,7 and one patient presented dilated pulmonary annulus with a Z score of + 2.5. CONCLUSION: In midium-term follow-up, the decellularized allograft seemed to be a good option for right ventricle outflow tract enlargement in patients underwent tetralogy of Fallot.


Asunto(s)
Niño , Preescolar , Humanos , Lactante , Implantación de Prótesis de Válvulas Cardíacas/métodos , Tetralogía de Fallot/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica , Sistema Libre de Células , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/normas , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar , Factores de Tiempo , Resultado del Tratamiento , Tetralogía de Fallot/fisiopatología , Tetralogía de Fallot , Disfunción Ventricular Derecha/fisiopatología , Disfunción Ventricular Derecha/cirugía , Disfunción Ventricular Derecha , Obstrucción del Flujo Ventricular Externo/fisiopatología , Obstrucción del Flujo Ventricular Externo/cirugía , Obstrucción del Flujo Ventricular Externo , Presión Ventricular/fisiología
11.
Indian Heart J ; 2003 Mar-Apr; 55(2): 185-7
Artículo en Inglés | IMSEAR | ID: sea-3615

RESUMEN

Heart-lung transplantation is a well accepted and standard form of therapy for the surgical management of patients with end-stage cardiopulmonary disorders. The first heart-lung transplant in India was performed at our institution on May 3, 1999 and, subsequently, 2 more patients have undergone this procedure. The initial experience is encouraging and heralds a new era of thoracic organ transplantation in India.


Asunto(s)
Adulto , Complejo de Eisenmenger/cirugía , Femenino , Defectos del Tabique Interatrial/cirugía , Defectos del Tabique Interventricular/cirugía , Trasplante de Corazón-Pulmón/tendencias , Humanos , Hipertensión Pulmonar/cirugía , India/epidemiología , Masculino , Disfunción Ventricular Derecha/cirugía
12.
Rev. bras. cir. cardiovasc ; 8(1): 20-38, jan.-mar. 1993. ilus, tab
Artículo en Portugués | LILACS | ID: lil-162583

RESUMEN

A obstruçao da via de saída do ventrículo direito (VSVD) tem gerado muita polêmica em torno da técnica da sua correçao cirúrgica, sendo a reconstituiçao ainda motivo de controvérsias. Com essa finalidade, foram desenvolvidas duas próteses a partir do tronco pulmonar (TP) de porco: 1) a prótese bivalvular: poderia ser usada na correçao da tétrade de Fallot associada a hipoplasia do anel pulmonar: 2) a prótese tubular valvada, possuindo a própria valva pulmonar: poderia ser empregada na correçao de malformaçoes com descontínuidade entre o VD e TP. Estes dois tipos de próteses foram testados em modelo experimental. Seis ovelhas foram submetidas a implante de prótese bivalvular, com o auxílio da circulaçao extracorpórea (CEC), após ampla ressecçao do infundíbulo pulmonar, incluindo duas válvulas da valva pulmonar, procurando-se, com isto, imitar a reconstituiçao empregada no Fallot. O implante da protese tubular valvada foi realizado em 12 ovelhas, sem o auxílio da CEC, mediante pinçamento tangencial do infundíbulo e TP, permitindo o desvio do fluxo sangüíneo através do conduto, após ligadura do TP. A prótese bivalvular implantada foi avaliada mediante parâmetros hemodinâmicos e ecocardiográficos na fase intra-operatória, conferindo desempenho satisfatório (insuficiência pulmonar discreta ou ausente e gradientes VD-TP menores de 10 mmHg). A seguir, os animais foram sacrificados. O desempenho da prótese tubular valvada foi avaliada na fase intra-operatória com medidas hemodinâmicas, mostrando gradientes acima de 1O mmHg em apenas 3 casos. Sete ovelhas tiveram controle ecocardiográfico com 99 a 135 dias de evoluçao, registrando gradientes de 9,85 mmHg a 49 mmHg (média 19,7). Quatro casos foram submetidos a estudo hemodinâmico no 6( mês de evoluçao, registrando discreto aumento do gradiente (média 22,3); a seguir os animais foram sacrificados e encaminhados para estudo anatomopatológico. A aplicaçao clínica da prótese bivalvular foi realizada em 3 pacientes portadores de t.de Fallot associada a hipoplasia do anel pulmonar (2 casos) e agenesia da valva pulmonar (1 caso), com idades de 16, 2 e 7 anos. Após evoluçao de 3 a 10 meses, os gradientes variaram entre 10 mmHg e 20 mmHg e discreta insuficiência pulmonar valvar ao estudo ecodopplercardiográfico...


Asunto(s)
Humanos , Animales , Masculino , Femenino , Preescolar , Niño , Adolescente , Bioprótesis , Disfunción Ventricular Derecha/cirugía , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar/cirugía , Ovinos , Tetralogía de Fallot/cirugía , Calcinosis/patología , Cineangiografía , Ecocardiografía Doppler , Circulación Extracorporea , Estudios de Seguimiento , Hemodinámica , Monitoreo Intraoperatorio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA