Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Chinese Journal of Medical Genetics ; (6): 47-51, 2024.
Artículo en Chino | WPRIM | ID: wpr-1009352

RESUMEN

OBJECTIVE@#To delineate a deletional mutation of the HLA-B gene in a Chinese pedigree.@*METHODS@#A female patient with acute myeloid leukemia who had visited Liuzhou People's Hospital in April 2022 was selected as the study subject. Routine human leukocyte antigen (HLA) was determined by using PCR-sequence specific oligonucleotide polymorphism (PCR-SSOP) and PCR-sequence-based typing (PCR-SBT) methods. Next generation sequencing (NGS) was used to validate the candidate variant in the HLA-B gene.@*RESULTS@#The PCR-SBT and SSOP results for the HLA-B locus were inconsistent for the patient and her daughter. The SSOP results of the two individuals were HLA-B*35:01, 40:02 and HLA-B*35:01, 40:01, respectively. However, the PCR-SBT results has indicated a mismatch with the nearest HLA-B*35:01 at exon 4. NGS results showed that the HLA-B*35:01 had a 9 bp deletion in the intron 5. The patient's husband was HLA-B*40:01, 58:01, which was normal.@*CONCLUSION@#The variant in intron 5 of the HLA-B gene in this pedigree has mapped to a primer-binding region for the SBT reagent, which has affected the accuracy of PCR-SBT results.


Asunto(s)
Humanos , Femenino , Alelos , Linaje , Antígenos HLA/genética , Antígenos HLA-B/genética , China , Prueba de Histocompatibilidad/métodos , Análisis de Secuencia de ADN/métodos
2.
Journal of Experimental Hematology ; (6): 203-208, 2023.
Artículo en Chino | WPRIM | ID: wpr-971125

RESUMEN

OBJECTIVE@#To confirm the HLA genotypes of the samples including 4 cases of magnetic bead probe HLA genotyping result pattern abnormality and 3 cases of ambiguous result detected by PCR sequence-specific oligonudeotide probe (SSOP) method.@*METHODS@#All samples derived from HLA high-resolution typing laboratory were detected by PCR-SSOP. A total of 4 samples of magnetic bead probe HLA genotyping result pattern abnormality and 3 samples of ambiguous result were further confirmed by PCR sequence-based typing (SBT) technology and next-generation sequencing (NGS) technology.@*RESULTS@#A total of 4 samples of magnetic bead probe HLA genotyping result pattern abnormality were detected by PCR-SSOP method. The results of SBT and NGS showed that the HLA-A genotype of sample 1 did not match any known genotypes. NGS analysis revealed that the novel allele was different from the closest matching allele A*31:01:02:01at position 154 with G>A in exon 2, which resulting in one amino acid substitution at codon 28 from Valine to Methionine (p.Val28Met). The HLA-C genotype of sample 2 was C*03:119, 06:02, sample 3 was C*03:03, 07:137, and sample 4 was B*55:02, 55:12. A total of 3 samples with ambiguous result were initially detected by PCR-SSOP method. The re-examination results of SBT and NGS showed that the HLA-B genotype of sample 5 was B*15:58, 38:02, sample 6 was DRB1*04:05, 14:101, and sample 7 was DQB1*03:34, 05:02. Among them, alleles C*03:119, C*07:137 and DRB1*14:101 were not included in the Common and Well-documented Alleles (CWD) v2.4 of the Chinese Hematopoietic Stem Cell Donor Database.@*CONCLUSION@#The abnormal pattern of HLA genotyping results of magnetic probe by PCR-SSOP method suggests that it may be a rare allele or a novel allele, which needs to be verified by sequencing.


Asunto(s)
Humanos , Alelos , Reacción en Cadena de la Polimerasa , Genotipo , Secuenciación de Nucleótidos de Alto Rendimiento , Prueba de Histocompatibilidad/métodos , Tecnología
5.
Rev. cuba. hematol. inmunol. hemoter ; 31(1): 32-40, ene.-mar. 2015.
Artículo en Español | LILACS | ID: lil-743984

RESUMEN

Introducción: el trasplante es la terapia que permite la mayor sobrevida a los pacientes con insuficiencia renal crónica. Para prevenir el rechazo del órgano, en primer lugar es necesario un estudio de la compatibilidad de los antígenos leucocitarios humanos (HLA) del paciente y de los posibles donantes. En Cuba solo se había realizado la tipificación HLA por métodos serológicos, pero en la actualidad se emplean técnicas moleculares. Objetivo: caracterizar el polimorfismo de los alelos HLA A, B, DR y DQ por métodos moleculares en pacientes cubanos en espera de trasplante renal. Métodos: se estudiaron 410 pacientes con insuficiencia renal crónica de las regiones occidental y central del país a los que se les realizó tipificación molecular de los loci mencionados. Los resultados se expresaron según la nueva nomenclatura y fueron registrados en una base de datos confeccionada al efecto. Se compararon las frecuencias alélicas de la población blanca y no blanca y se determinó el porcentaje de frecuencia de los haplotipos para los alelos clase I y II. Resultados: los alelos A*11, A*30, A*74, B*42, B*51 y B*53 fueron más frecuentes en la población blanca mientras que los alelos B*58 y DRB1* 15 predominaron en los no blancos. Las frecuencias haplotípicas más encontradas en la clase I en la población blanca fueron A*02 B*51, A*02 B*44, A*02 B*35; y en la no blanca, A*01B*08, A*02B*51, A*02B*44. Para los alelos de la clase II, en la población blanca fueron DQB1*03, DRB1*04, DQB1*06, DRB1*13, DRB1*05, DRB1*01; y en los no blancos, DQB1*03, DRB1*04, DQB1*06, DRB1*13, DQB1*05, DRB1*01. Conclusiones: la caracterización de los pacientes con insuficiencia renal crónica con respecto a su tipificación HLA permitirá trazar estrategias futuras relacionadas con la donación y el trasplante en todo el país(AU)


Introduction: transplantation is the therapy allowing the highest possible survival in patients with chronic kidney insufficiency. To prevent rejection of the organ, first of all it is necessary to make a compatibility test of human leukocyte antigens (HLA) from the patient and the possible donors. In Cuba, only serological HLA typing had been made but at present, molecular techniques are being applied. Aim: characterization of polimorfirsm of alleles HLA A, B, DR y DQ by molecular techniques in Cuban patients awaiting renal transplantation. Methods: four hundred and ten patients with chronic kidney insufficiency from Western and Central Cuba were studied by molecular typing of the above mentioned loci. Results were expressed by the new nomenclature and were registered In a data base prepared for that purpose. Allele frequencies of white and no white population were compared and percentage of haplotype frequencies for alleles class I and II were determined. Results: alleles A*11, A*30, A*74, B*42, B*51and B*53 were more frequent in white population while B*58 y DRB1*, 15 were mostly found in no whites. Haplotypic frequencies most found in class I in white population were A*02 B*51, A*02 B*44, A*02 B*35; and in no whites, A*01B*08, A*02B*51, A*02B*44. For class II alleles, DQB1*03, DRB1*04, DQB1*06, DRB1*13, DRB1*05, DRB1*01 were the most found in white population; and in no whites, DQB1*03, DRB1*04, DQB1*06, DRB1*13, DQB1*05, DRB1*01. Conclusions: characterization of patients with chronic kidney insufficiency in respect to HLA typing will allow future strategies related to kidney donation and transplantation in the whole country(AU)


Asunto(s)
Humanos , Masculino , Femenino , Antígenos HLA/inmunología , Insuficiencia Renal Crónica/genética , Cuba , Prueba de Histocompatibilidad/métodos , Trasplante de Riñón/métodos
6.
Clinics ; 69(supl.1): 17-21, 1/2014.
Artículo en Inglés | LILACS | ID: lil-699020

RESUMEN

The sensitization of patients to human leukocyte antigens prior to heart transplantation is increasingly being recognized as an important challenge both before and after the transplant, and the effects of sensitization on clinical outcomes are just beginning to be understood. Many patients are listed with the requirement of a negative prospective or virtual crossmatch prior to accepting a donor organ. This strategy has been associated with both longer waitlist times and higher waitlist mortality. An alternative approach is to transplant across a potentially positive crossmatch while utilizing strategies to decrease the significance of the human leukocyte antigen antibodies. This review will examine the challenges and the impact of sensitization on pediatric patients prior to and following heart transplantation.


Asunto(s)
Niño , Humanos , Anticuerpos/inmunología , Trasplante de Corazón , Antígenos HLA/inmunología , Rechazo de Injerto/inmunología , Prueba de Histocompatibilidad/métodos , Cuidados Posoperatorios , Cuidados Preoperatorios , Resultado del Tratamiento , Inmunología del Trasplante/inmunología , Listas de Espera
7.
Rev. cuba. invest. bioméd ; 31(1): 81-86, ene.-mar. 2012.
Artículo en Español | LILACS | ID: lil-644737

RESUMEN

En el ensayo de microlinfocitotoxicidad, el suero de conejo como fuente de complemento desempeña un rol esencial en la clasificación del complejo mayor de histocompatibilidad humano, tanto para la tipificación antigénica como en el cross-match linfocitario de la pareja donante-receptor antes de realizar los trasplantes. En este trabajo, se obtuvieron 3 lotes experimentales de dicho hemoderivado con óptimos indicadores de rendimiento, actividad biológica y estabilidad. El exanguíneo de los animales se realizó por la técnica de yugulación. El suero fue separado por centrifugación en condiciones ambientales y de temperatura controladas. Posteriormente, el producto se sometió a filtración esterilizante y se tomaron muestras para los ensayos de calidad. El estudio mostró que el producto conserva la actividad biológica al menos durante 18 meses y que los valores de citotoxicidad se encuentran dentro de los límites de aceptación para su empleo en los ensayos de histocompatibilidad pretrasplante


Microlinfocitotoxicity assay is one of the serological methods used to classify human major histocompatibility complex. In this technique the rabbit´s serum as complement source, plays an essential role in antigens determination and in lymphocytes cross match assay as necessary stage before the selection of the best donor-receiver pair to realize the organ transplant. Three experimental lots of normal rabbit serum were developed with excellent indicators of efficiency, biological activity and stability. Rabbit's blood was obtained through jugulating technique and serum was separated by centrifugation in controlled environment and temperature´s conditions. The sterilization process was performed by filtration and the samples were taken for quality´s control assays. Stability studies showed that the product kept the biological activity at least during 18 months after it was processed and cytotoxicity's values were adequate for its employment in histocompatibility pre-transplant assays


Asunto(s)
Conejos , Ensayo de Actividad Hemolítica de Complemento/métodos , Antígenos de Histocompatibilidad , Trasplante de Órganos , Prueba de Histocompatibilidad/métodos
8.
Indian J Med Microbiol ; 2011 Oct-Dec; 29(4): 414-417
Artículo en Inglés | IMSEAR | ID: sea-143867

RESUMEN

Complement-dependent lymphocytotoxicity crossmatches (n=217) between 47 deceased donors and 150 potential renal recipients were retrospectively studied. A negative cross match was reported in 48 (22.1%), doubtful positive in 126 (58.1%), weakly positive in 32 (14.7%) and positive in 11 (5.1%). No autoantibodies were detected. Renal transplantation was performed in 35.5% of the potential recipients. There was no incidence of hyperacute rejection. The graft survival rate was 88% at 15 months of follow up. The study concludes that a negative pretransplant lympocytotoxicity crossmatch using the basic National Institute of Health technique eliminates hyperacute rejection, but carries drawbacks, which require modification and supplementation with more sensitive and specific assays.


Asunto(s)
Adolescente , Adulto , Anciano , Niño , Preescolar , Proteínas del Sistema Complemento/inmunología , Pruebas Inmunológicas de Citotoxicidad/métodos , Femenino , Rechazo de Injerto/inmunología , Supervivencia de Injerto/inmunología , Prueba de Histocompatibilidad/métodos , Humanos , Trasplante de Riñón/inmunología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
9.
Journal of Korean Medical Science ; : 528-533, 2011.
Artículo en Inglés | WPRIM | ID: wpr-173910

RESUMEN

The clinical significance of positive B-cell complement-dependent cytotoxicity crossmatching (B-CDC) in renal transplant recipients remains unclear. We reviewed 20 recipients with isolated B-CDC positivity at the time of transplantation. We compared the clinical characteristics, acute rejection and long-term graft survival between positive and negative B-CDC patients (n = 602). The number of retransplant recipients and positivity for T- and B-flowcytometric crossmatch was greater in positive B-CDC patients than in negative B-CDC patients. The overall acute rejection rate of positive B-CDC patients was significantly higher (P < 0.001), and Banff grade II or III cellular rejection was more frequently observed in positive B-CDC patients (P = 0.037). Compared with negative B-CDC patients, acute cellular rejection as a cause of graft loss was more prevalent (P = 0.020) and rescue rejection therapy was more frequently needed in positive B-CDC patients (P = 0.007). The allograft survival rate of positive B-CDC patients was significantly lower than that of negative B-CDC patients (P < 0.001), and B-CDC positivity independently increased the risk of allograft failure 2.31-fold (95% CI 1.15-4.67; P = 0.019) according to multivariate analysis. In conclusion, isolated B-CDC positivity is an independent long-term prognostic factor for allograft survival.


Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Aguda , Linfocitos B/inmunología , Activación de Complemento , Pruebas Inmunológicas de Citotoxicidad , Supervivencia de Injerto/inmunología , Prueba de Histocompatibilidad/métodos , Trasplante de Riñón/inmunología , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Análisis de Supervivencia , Linfocitos T/inmunología , Trasplante Homólogo
10.
The Korean Journal of Laboratory Medicine ; : 668-674, 2010.
Artículo en Coreano | WPRIM | ID: wpr-73301

RESUMEN

BACKGROUND: In unrelated hematopoietic stem cell transplantation, the accuracy of HLA registry typing (RT) of donors is important for timely search and coordination of HLA-matched donors. We analyzed discrepancies between HLA RT and confirmatory typing (CT) results of stem cell donors in Korean and foreign registries. METHODS: We analyzed the HLA typing results of 834 donors for whom CT was performed at Seoul National University Hospital between April 1997 and March 2010. For CT, DNA typing was used in majority of the cases and HLA-A and HLA-B serological typing was used in some early cases. The discrepancies between the typing results were analyzed at the serological/generic level. RESULTS: The overall discrepancy rate (RT error rate) was 3.2%, and the rate was similar in the Korean and foreign registries. The discrepancy rates in the Korean and foreign registries were more than 10% in the 1997-2001 searches, but decreased to less than 3% in the 2002-2010 searches. Analysis of 19 cases of RT errors in the Korean registry revealed 3 cases of sample switchover errors and 16 cases of typing errors in one of the HLA-A, HLA-B, or HLA-DR loci. The RT error rate in Japan Marrow Donor Program was lower than those in other foreign registries. CONCLUSIONS: The error rate of HLA RT results of unrelated stem cell donors in the Korean registry was similar to those in the foreign registries, and has decreased in the recent searches following the change in the typing method from serological to DNA typing.


Asunto(s)
Humanos , Errores Diagnósticos/estadística & datos numéricos , Antígenos HLA/genética , Trasplante de Células Madre Hematopoyéticas , Células Madre Hematopoyéticas/metabolismo , Prueba de Histocompatibilidad/métodos , Sistema de Registros , Donantes de Tejidos
11.
Journal of Korean Medical Science ; : S143-S147, 2009.
Artículo en Inglés | WPRIM | ID: wpr-98685

RESUMEN

A successful transplantation, across a positive crossmatch barrier, is one of the most persistent long- standing problems in the field of kidney transplant medicine. The aim of this study was to describe seven consecutive living renal transplantations in recipients with positive crossmatch for donors or positive for donor specific antibodies (DSAs). A preconditioning regimen including plasmapheresis and intravenous immunoglobulin was delivered three times a week until the crossmatch and/ or DSAs became negative. Mycophenolate mofetil and tacrolimus were started two days before the plasmapheresis. The protocol was modified to include administration of anti-CD 20 antibody (rituximab, 375 mg/m(2)) from the patient number 3 through the patient number 7. All seven patients achieved negative conversion of the crossmatch or DSAs, and the kidney transplantations were successfully performed in all cases. Acute cellular rejection occurred in two patients, which were subclinical and controlled with high dose steroid treatment. Antibody-mediated rejection occurred in one patient, which was easily reversed with plasmapheresis. All recipients attained normal graft function during the 7-24 months of follow up. Our study suggests that sensitized patients can be transplanted successfully with desensitization pretreatment.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Anticuerpos Monoclonales/farmacología , Antígenos CD20/biosíntesis , Biopsia , Rechazo de Injerto , Supervivencia de Injerto , Prueba de Histocompatibilidad/métodos , Inmunoglobulinas/química , Trasplante de Riñón/métodos , Plasmaféresis , Acondicionamiento Pretrasplante
12.
The Korean Journal of Laboratory Medicine ; : 589-593, 2009.
Artículo en Inglés | WPRIM | ID: wpr-106754

RESUMEN

BACKGROUND: The standard PCR with sequence-specific primers (SSP) is a widely used method of HLA-B27 typing in clinical practice. The aim of our study was to evaluate 2 Korean HLA-B27 kits with different real-time PCR chemistries. METHODS: To validate the accuracy of real-time PCR kits, we selected 28 HLA-B27-positive samples and 33 HLA-B27-negative samples with a wide range of different HLA-B specificities typed by standard PCR-SSP. The 2 real-time PCR kits used were the AccuPower(R) HLA-B27 real-time PCR kit (Bioneer, Korea) with TaqMan probes and the Real-Q(TM) HLA-B*27 detection kit (BioSewoom, Korea) with SYBR Green I dye for melting curve analysis. RESULTS: All 61 samples typed by PCR-SSP demonstrated a perfect concordance with the 2 real-time PCR assays. It was possible to clearly discriminate between HLA-B27-positive and -negative samples in both real-time assays. CONCLUSIONS: In summary, both real-time PCR assays for HLA-B27 were fast, reliable, well-adapted for routine laboratory testing, and attractive alternatives to the conventional PCR-SSP method.


Asunto(s)
Humanos , Antígeno HLA-B27/análisis , Prueba de Histocompatibilidad/métodos , Compuestos Orgánicos/química , Reacción en Cadena de la Polimerasa , Juego de Reactivos para Diagnóstico , Temperatura de Transición
13.
J Postgrad Med ; 2008 Jan-Mar; 54(1): 41-4
Artículo en Inglés | IMSEAR | ID: sea-116990

RESUMEN

Serology-based conventional microlymphocytotoxicity HLA typing method, which has been regarded as the gold standard in organ and hematopoietic stem cell transplantation, has been replaced now by DNA-based typing. Many laboratories all over the world have already switched over to molecular methods. Microlymphocytotoxicity-based tissue typing was done using commercial sera, while the molecular typing by genomic DNA based. DNA quality and its quantity obtained using various DNA extraction protocols was found to be an important factor in the molecular method of tissue typing in transplant outcome. Many polymerase chain reaction-based molecular techniques have been adopted with far reaching clinical outcome. The sequence-based typing (SBT) has been the ultimate technique, which has been of the highest reliability in defining the HLA alleles. The nonavailability of specific HLA antisera from native populations, large number of blank alleles yet to be defined and comparable low resolution of HLA alleles in SSP or SSOP technique, suggests that highly refined DNA-based methods like SBT should be used as an adjunct to HLA serology and/or low/intermediate/high resolution HLA typing in order to achieve a better transplant outcome.


Asunto(s)
Secuencia de Bases/genética , ADN/análisis , Antígenos HLA/genética , Prueba de Histocompatibilidad/métodos , Humanos , Reacción en Cadena de la Polimerasa/métodos , Análisis de Secuencia de ADN/métodos , Pruebas Serológicas/métodos , Inmunología del Trasplante/genética
14.
The Korean Journal of Laboratory Medicine ; : 239-243, 2008.
Artículo en Coreano | WPRIM | ID: wpr-206225

RESUMEN

BACKGROUND: Commercial kits of PCR method are widely used in HLA-B27 typing; however, their cost is relatively high. In this study, we evaluated the utility of an in-house PCR method by comparing it with that of a commercial kit. METHODS: HLA-B27 typing was done in 188 patients by using two PCR methods, Absolute(TM) HLAB27 PCR kit (Biosewoom, Korea) and an in-house PCR method. The primers used in the in-house method were prepared by Bioneer (Korea). Both PCR tests were done by Gene Amp PCR System 9600 (Perkin-Elmer Centus Corp., USA). RESULTS: The commercial kit and in-house PCR showed 100% concordance rate with each other in HLA-B27 typing. Of 188 patients tested 72 (38.3%) were positive and 116 (61.7%) were negative by the both tests. Of 62 patients with ankylosing spondylitis, 50 were positive (80.7%). CONCLUSIONS: The in-house PCR is a reliable and cost-effective method and can replace or supplement commercial kits for HLA-B27 typing.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Antígeno HLA-B27/sangre , Prueba de Histocompatibilidad/métodos , Reacción en Cadena de la Polimerasa/métodos , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad
15.
Pakistan Journal of Pathology. 2008; 19 (4): 121-125
en Inglés | IMEMR | ID: emr-99831

RESUMEN

To determine the validity of in-house assay for DNA based HLA class II typing against commercial kit as gold standard. Validation Study. Department of Immunology, Armed Forces Institute of Pathology, Rawalpindi, from Feb 2006 to March 2007. 56 cases referred to Immunology Department for HLA class II typing were included in the study and each subject tested by both the assays. INNO-LiPA assay was done by commercial kits which are based on sequence specific oligonucleotide probes. For in-house assay, individual reagents were obtained from commercial sources and protocol of the assay was established. The results of in-house assay were compared with INNO-LiPA kit. The sensitivity and specificity of in-house assay as compared to commercial assay were calculated, for each of the individual alleles identified, and at the end, cumulative sensitivity and specificity were found to be 92% and 99% respectively. High sensitivity, specificity, cost effectiveness and being easy to perform, make in-house assay a suitable alternative approach for performing HLA-DRB1 typing, especially in renal transplant patients where it can replace serological techniques. In addition, with the addition of primers for new alleles, it can be used to resolve any ambiguity that arises during the course of commercial testing. However, further work is required to study and analyze primers for DRB1 03 and DRB115, to make in-house assay, a cost effective method for low resolution typing


Asunto(s)
Humanos , Masculino , Femenino , Genes MHC Clase II , Prueba de Histocompatibilidad/métodos , ADN , Alelos , Antígenos HLA-DR , Antígenos de Histocompatibilidad Clase II , Antígenos de Histocompatibilidad Clase II
16.
The Korean Journal of Laboratory Medicine ; : 360-368, 2007.
Artículo en Coreano | WPRIM | ID: wpr-148426

RESUMEN

BACKGROUND: Human leukocyte antigen (HLA) typing based on polymerase chain reaction (PCR) is rapidly replacing the conventional serological method. This study was intended to evaluate Bio- SewoomTM HLA-A, -B, -C PCR/SSP kit (BioSewoom SSP) which had recently been developed in Korea. METHODS: A total of 158 samples from domestic (21) and international (137) HLA proficiency testing (PT) were genotyped with BioSewoom SSP, and its results were compared to consensus results. For comparison with INNO-LiPA HLA-A, -B, -C Typing Kit (INNO-LiPA, Innogenetics, Belgium), 20 samples of Koreans were genotyped with both kits for each HLA-A, -B, -C locus. RESULTS: Among the 21 samples of domestic PT, BioSewoom SSP showed ambiguities as follows: 4 samples (19.0%) in HLA-A, 6 (28.6%) in HLA-B, and 1 (4.8%) in HLA-C. The ambiguities could be resolved by considering the allele distribution of Koreans. Among the 137 samples from international PT, BioSewoom SSP also showed ambiguities as follows: 12 samples (8.8%) in HLA-A, 26 (19.0%) in HLA-B and 6 (4.4%) in HLA-C. Considering the allele distribution of Koreans, the serologic equivalents obtained from BioSewoom SSP showed a full agreement with those of INNO-LiPA in all the loci tested. Twelve (0.007%) among 1,760 PCR reactions from the 21 samples of domestic PT and 20 patient samples produced faint nonspecific bands, but it was negligible. PCR failure of internal control just barely occurred (15 PCR reactions, 0.009%), but it had no bearing on allele assignment. CONCLUSIONS: The performance of BioSewoom SSP was comparable to that of INNO-LiPA. All the ambiguities could be resolved by considering the allele distribution of Koreans. It is concluded that BioSewoom SSP has good performance to be used in routine HLA laboratories.


Asunto(s)
Humanos , Alelos , Genotipo , Antígenos HLA-A/genética , Antígenos HLA-B/genética , Antígenos HLA-C/genética , Prueba de Histocompatibilidad/métodos , Reacción en Cadena de la Polimerasa/métodos , Juego de Reactivos para Diagnóstico
17.
Braz. j. med. biol. res ; 38(6): 837-842, June 2005. ilus, tab
Artículo en Inglés | LILACS | ID: lil-402664

RESUMEN

In order to detect several new HLA-A class I alleles that have been described since 1998, the original PCR-RFLP method developed to identify the 78 alleles recognized at that time at high resolution level was adapted by us for low and medium resolution levels using a nested PCR-RFLP approach. The results obtained from blood samples of 23 subjects using both the PCR-RFLP method and a commercial kit (MicroSSP1A®, One Lambda Inc.) showed an agreement higher than 95 percent. The PCR-RFLP adapted method was effective in low and medium resolution histocompatibility evaluations.


Asunto(s)
Humanos , Genes MHC Clase I/genética , Antígenos HLA-A/genética , Prueba de Histocompatibilidad/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Alelos , Análisis de Secuencia de ADN/métodos
18.
Journal of Forensic Medicine ; (6): 120-123, 2004.
Artículo en Chino | WPRIM | ID: wpr-983028

RESUMEN

Over a long period of time, studies on HLA structure and function have been the research hotspots. for it is very important to understand the essential of life science and disease mechanism. With the rapid development of molecular biology, HLA typing makes great progress. It has changed from traditional serological typing to DNA-based typing. More and more HLA genotyping methods have been developed and applied. In this essay, the author reviewed and appraised all kinds of HLA genotyping techniques and introduced two new techniques.


Asunto(s)
Humanos , Cartilla de ADN , Técnicas Genéticas , Genotipo , Antígenos HLA/genética , Prueba de Histocompatibilidad/métodos , Análisis de Secuencia por Matrices de Oligonucleótidos , Sondas de Oligonucleótidos , Reacción en Cadena de la Polimerasa/métodos , Polimorfismo de Longitud del Fragmento de Restricción , Polimorfismo Conformacional Retorcido-Simple , Análisis de Secuencia de ADN/métodos
19.
Southeast Asian J Trop Med Public Health ; 2002 ; 33 Suppl 2(): 112-4
Artículo en Inglés | IMSEAR | ID: sea-31782

RESUMEN

The human leukocyte antigen (HLA) region on chromosome 6p21.3 is the most polymorphic in the human genome. It encodes hundreds of genes, of which the class I and class II HLA alleles play a central role in the generation of an immune response, but at the same time represent a barrier to marrow and organ transplantation. There is overwhelming evidence that optimal HLA matching will allow for safer marrow transplants, however with more than 1,200 allelic variants, the need to accurately identify the precise alleles is a technically demanding challenge. Methods currently in use for HLA typing include microcytotoxity assay, sequence-specific oligonucleotide (SSO) probe, sequence-specific primer (SSP) amplification, and sequence-based typing (SBT). Ambiguous results may still arise, even with the best molecular typing methods but this problem can be resolved by using a combination of methods. It is clear that a HLA typing laboratory will have to provide allele level resolution of HLA data using the most appropriate means available and this will have the greatest impact in terms of offering the best matched donor for the benefit of patients.


Asunto(s)
Alelos , Prueba de Histocompatibilidad/métodos , Humanos , Análisis de Secuencia de ADN
20.
Southeast Asian J Trop Med Public Health ; 1999 Jun; 30(2): 311-3
Artículo en Inglés | IMSEAR | ID: sea-33813

RESUMEN

In this study, serological HLA-DR typing results were compared to typing results obtained with sequence-specific primers in the polymerase chain reaction (PCR-SSP). HLA-DR typing was performed on 120 random Thai individuals. Differences in HLA-DR typing results were found in 18 out of 120, which were due to cross reactive antibodies and the lack of potent antisera to define proper HLA-DR splits by serology. Furthermore, PCR-SSP is fast and easy to perform as HLA-DR typing results can be obtained within 2 hours. From the results of this study it can be concluded that PCR-SSP is a reliable and promising technique for HLA-DR typing which can replace the serological technique in routine clinical practice.


Asunto(s)
Anticuerpos Monoclonales , Cartilla de ADN , Antígenos HLA-DR/análisis , Prueba de Histocompatibilidad/métodos , Humanos , Reacción en Cadena de la Polimerasa/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Pruebas Serológicas , Tailandia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA