Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
2.
Rev. méd. Chile ; 150(11): 1422-1430, nov. 2022. tab, graf
Artículo en Español | LILACS | ID: biblio-1442047

RESUMEN

BACKGROUND: Transcatheter aortic-valve implantation (TAVI) was introduced in 2002 and the first implants in our country were performed in 2010. AIM: To review the TAVI experience in our hospital, considering the technology improvements and gained experience throughout this period. MATERIAL AND METHODS: All patients undergoing TAVI in our center were included. Results and complications were adjudicated according to the Valve Academic Research Consortium-2 (VARC-2) criteria. Patients were divided in 3 groups, according to procedural year: Period 1: 2010-2015 (n = 35); Period 2: 2016-2018 (n = 35); Period 3: 2019-2021 (n = 41). Mortality up to one year after the procedure was recorded. RESULTS: Between 2010 and 2021, 111 TAVI procedures were performed. The mean age of patients was 82 years and 47% were women. Risk scores for in-hospital mortality were STS 6.7%, EUROSCORE II 8.0% and ACC/STS TAVR Score 4.9%. The trans-femoral route was used in 88% and a balloon-expandable valve was chosen in 82% of patients. A successful implant was achieved in 96%, with an in-hospital mortality of 1.8%. Mortality at 30 days and 1-year were 2.7 and 9.0%, respectively. During period 3, 100% of implants were successful, with no in-hospital mortality, less vascular complications (p < 0.01), less stroke (p = 0.04), less severe paravalvular leak (p = 0.01) and significantly lower rate of acute complications (p < 0.01). CONCLUSIONS: TAVI achieves excellent results. With greater experience and better available technologies, these results are even more favorable.


Asunto(s)
Humanos , Masculino , Femenino , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Factores de Riesgo , Resultado del Tratamiento
3.
Braz. J. Anesth. (Impr.) ; 72(5): 629-636, Sept.-Oct. 2022. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1420601

RESUMEN

Abstract Background and objectives We aimed to investigate the effects of two different anesthetic techniques in our patients who underwent transcatheter aortic valve implantation (TAVI). Methods In this study, 303 patients who underwent TAVI procedure with a diagnosis of severe aortic stenosis between January 1, 2012 and December 31, 2018 were retrospectively evaluated. The patients were divided according to the type of anesthesia given during each procedure as; general anesthesia (GA), local anesthesia (LA). Results LA was preferred in 245 (80.8%) of 303 patients who underwent TAVI, while GA was preferred in 58 patients (19.1%). Median ages ​​of our patients who received LA and GA were 83 and 84, respectively. The procedure and anesthesia durations of the patients in the GA group were longer than the LA group (p< 0.00001, p< 0.00001, respectively). Demographic and pre-operative clinical data were similar in comparison between two groups (p> 0.05) except for peripheral artery disease. Hypertension was the most common comorbidity in both groups. While the number of inotrope use was significantly higher in patients who received GA (p< 0.00001), no significant differences were found between LA and GA patients in terms of major complications and mortality (p> 0.05). Intensive care and hospital stays were significantly shorter in the LA group (p= 0.001, p= 0.023, respectively). Conclusion The anesthetic technique of TAVI procedure did not have a significant effect on outcomes including; complications, mortality and success of the procedure. LA provides shorter duration of procedure and hospital stay.


Asunto(s)
Humanos , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Factores de Riesgo , Anestésicos , Complicaciones Posoperatorias/etiología , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anestesia General , Anestesia Local
5.
Rev. méd. Chile ; 150(2): 183-189, feb. 2022. tab
Artículo en Español | LILACS | ID: biblio-1389642

RESUMEN

COVID-19 pandemic generated multiple challenges for the health system. Cardiovascular disease is associated with a worse prognosis of infections. Moreover, most hospital resources and operative rooms were destined to patients with COVID-19 infection, deferring the treatment of most valvular patients requiring surgery. We report seven patients with symptomatic severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI) with conscious sedation and early discharge. No patient required intensive care unit admission or mechanical ventilation. After a 90-day follow-up, there were no complications or unplanned readmissions.


Asunto(s)
Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , COVID-19 , Alta del Paciente , Factores de Riesgo , Sedación Consciente/efectos adversos , Resultado del Tratamiento , Pandemias
6.
Chinese Journal of Cardiology ; (12): 142-149, 2022.
Artículo en Chino | WPRIM | ID: wpr-935118

RESUMEN

Objective: To investigate the efficacy and safety of left bundle branch pacing(LBBP) in patients after transcatheter aortic valve implantation (TAVI). Methods: This is a retrospective study. A total of 35 patients underwent TAVI and received pacemaker implantation from January 2018 to December 2020 in Beijing Fuwai Hospital were enrolled. Patients were divided into LBBP group (n=12) and right ventricular apex pacing (RVAP) group (n=23) according to the pacing position. The success rate of operation in LBBP group was calculated, and the occurrence of complications were observed, and the parameters of pacemaker were measured on the 3rd day and 1, 3 and 6 months after operation. The N-terminal pro-B-type natriuretic peptide (NT-proBNP), echocardiographic and ECG indexes were compared between the two groups on the 3rd day and 1, 3, and 6 months after pacemaker implantation. Result: A total of 35 patients were included, The age was (76.4±7.7) years, including 19 males (54.3%). The procedure time ((86.58±17.10)min vs. (68.74±9.18)min, P<0.001) and fluoroscopy duration ((20.08±4.44)min vs. (17.00±2.26)min, P<0.001) were significantly longer in LBBP group compared with RVAP group. The operation success rate of LBBP group was 11/12. There was no serious operation related complications such as pneumothorax, hemothorax, electrode dislocation, infection, and lower limb bleeding. The patients were followed up for 7.43 (5.21, 9.84) months. The programmed parameters of pacemaker were in the ideal range and stable during follow-up. At 3 and 6 months after operation, the left ventricular ejection fraction in LBBP group was higher than that in RVAP Group (at 3 months: (60.75±2.89)% vs. (57.35±3.33)%, P=0.004; at 6 months: (63.17±3.33)% vs. (56.17±3.97)%, P<0.001), NT-proBNP values was lower in LBBP group than that in RVAP Group (at 3 months: 822 (607, 1 150)ng/L vs. 1 052 (902, 1 536)ng/L, P=0.006; at 6 months: 440 (330,679)ng/L vs. 783 (588, 1 023)ng/L, P=0.001). At 1, 3 and 6 months after operation, the QRS duration was shorter in LBBP group than that in RVAP group (1 month: 99 (97, 107)ms vs. 126(124, 130)ms, P<0.001; 3 months: 98(96, 105)ms vs. 129(128, 133)ms, P<0.001; 6 months: 96(94, 104)ms vs. 130(128, 132)ms, P<0.001). Conclusions: For patients with permanent pacemaker indications after TAVI, LBBP is feasible, safe and reliable. It could improve the cardiac function in the short term, the long-term effect of LBBP needs to be further observed.


Asunto(s)
Anciano , Anciano de 80 o más Años , Humanos , Masculino , Fascículo Atrioventricular , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Fluoroscopía , Estudios Retrospectivos , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda
7.
Rev. bras. cir. cardiovasc ; 36(6): 796-801, Nov.-Dec. 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1351669

RESUMEN

Abstract Introduction: The Glasgow prognostic score (GPS) reflects host systemic inflammatory response and has been reported to be significant as a prognostic indicator in cancer-bearing patients. The aim of this study was to evaluate the predictive value of GPS in outcomes of patients with severe aortic stenosis who were treated with transcatheter aortic valve implantation (TAVI). Methods: The study population consisted of 79 patients who underwent TAVI due to severe aortic stenosis between January 2018 and March 2019 in our clinic. Echocardiographic and laboratory data were recorded before the procedure and GPS was scored as 0, 1, or 2, based on serum albumin and C-reactive protein levels. European System for Cardiac Operative Risk Evaluation II scoring system was used for risk stratification. The primary endpoints of the study were postoperative in-hospital mortality, hospitalization due to cardiac causes, or mortality within a year. Results: The 79 patients were classified into two groups according to outcomes. Fifteen patients (19%) reached the primary endpoints at one year of follow-up. Compared to the patients who did not reach the endpoints, these 15 patients were not different in terms of age, preoperative mean gradient, and ejection fraction (P>0.05 for all). GPS was the only laboratory parameter with statistically significant difference between the groups (P=0.008) and multivariate analysis showed that GPS was independent predictor of primary endpoints (P=0.012, odds ratio 4.51, 95% confidence interval 1.39-14.60). Conclusion: GPS is an easy, noninvasive laboratory test which may be used as a predictive biomarker for outcomes in patients undergoing TAVI.


Asunto(s)
Humanos , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Pronóstico , Factores de Tiempo , Biomarcadores , Factores de Riesgo , Resultado del Tratamiento
8.
Arq. bras. cardiol ; 117(5): 1018-1027, nov. 2021. tab, graf
Artículo en Inglés, Portugués | LILACS | ID: biblio-1350022

RESUMEN

Resumo Fundamento: A proteína C-reativa (PCR) é um biomarcador de inflamação preditor de eventos adversos em procedimentos cardiovasculares. Na avaliação do implante da válvula aórtica transcateter (transcatheter aortic valve implantation, TAVI) em relação ao prognóstico de longo prazo ainda é incipiente. Objetivo: Avaliar a PCR como marcador prognóstico no primeiro ano pós-TAVI na estenose aórtica (EAo). Métodos: A PCR foi avaliada na primeira semana do peroperatório numa coorte de casos retrospectiva com EAo. Correlacionou-se a PCR pré- e pós-TAVI com a mortalidade e foram pesquisados fatores preditores de mortalidade em 1 ano. Realizada regressão de Cox multivariada para identificar os preditores independentes de óbito em 1 ano. Resultados: Estudados 130 pacientes submetidos a TAVI, com mediana de idade de 83 anos, sendo 49% deles do sexo feminino. A PCR pré-TAVI elevada (> 0,5 mg/dL) ocorreu em 34,5% dos casos. O pico de PCR foi 7,0 (5,3-12,1) mg/dL no quarto dia. A mortalidade em 1 ano foi 14,5% (n = 19), sendo maior nos grupos com PCR pré-TAVI elevada (68,8% vs 29,1%; p = 0,004) e pico de PCR ≥ 10,0 mg/dL (64,7% vs 30,8%; p = 0,009). Os fatores preditores independentes de mortalidade foram insuficiência renal aguda (IRA) [razão de risco (RR) = 7,43; intervalo de confiança de 95% (IC95%), 2,1-24,7; p = 0,001], PCR pré-TAVI elevada [RR = 4,15; IC95%, 1,3-12,9; p=0,01] e hemotransfusão volumosa [HR = 4,68; 1,3-16,7; p = 0,02]. Conclusões: A PCR pré-TAVI elevada mostrou-se fator preditor independente de mortalidade no primeiro ano, assim como a ocorrência de IRA e hemotransfusões volumosas.


Abstract Background: C-reactive protein (CRP) is an inflammation biomarker that can be a predictor of adverse events in cardiovascular procedures. Its use in the assessment of long-term prognosis of transcatheter aortic valve implantation (TAVI) is still incipient. Objective: To evaluate CRP as a prognostic marker in the first year after TAVI in aortic stenosis (AoS). Methods: CRP was assessed on the first postoperative week in a retrospective cohort of patients with AoS. Pre- and post- CRP levels were correlated with mortality, and predictors of 1-year mortality were investigated. Multivariate Cox regression was performed to identify independent factors of 1-year mortality. Results: This study evaluated 130 patients who underwent TAVI, with median age of 83 years, and 49% of women. High pre-TAVI CRP (> 0.5 mg/dL) was observed in 34.5% of the cases. Peak CRP was 7.0 (5.3-12.1) mg/dL no quarto dia. The rate of 1-year mortality was 14.5% (n = 19), being greater in the groups with high pre-TAVI CRP (68.8% vs 29.1%; p = 0,004) and with peak CRP ≥ 10.0 mg/dL (64.7% vs 30.8%; p = 0,009). Independent predictors of mortality were acute renal failure (ARF) (hazard ratio [HR] = 7.43; 95% confidence interval [95%CI], 2.1-24.7; p = 0,001), high pre-TAVI CRP (HR 4.15; 95%CI, 1.3-12.9; p = 0.01), and large blood transfusion [HR 4,68; 1,3-16,7; p = 0.02]. Conclusions: High pre-TAVI CRP showed to be an independent predictor of 1-year mortality, as well as the presence of ARF and large blood transfusions.


Asunto(s)
Humanos , Masculino , Femenino , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/metabolismo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Pronóstico , Proteína C-Reactiva/análisis , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
9.
Rev. Assoc. Med. Bras. (1992) ; 67(9): 1311-1316, Sept. 2021. tab
Artículo en Inglés | LILACS | ID: biblio-1351458

RESUMEN

SUMMARY INTRODUCTION: According to recent studies, the rate of atrioventricular block requiring permanent pacing in patients following transcatheter aortic valve implantation varied between 5.7% and 42.5%. Fragmented QRS is a useful marker of myocardial scar and can predict adverse cardiac events. In this study, we examined association between f ragmented QRS and postprocedural rhythm disturbances and the need for permanent pacing in patients who underwent transcatheter aortic valve implantation. OBJECTIVE: In this study, we examined association between fragmented QRS and postprocedural rhythm disturbances and the need for permanent pacing in patients who underwent transcatheter aortic valve implantation' sentence is enough for it. METHODS: We retrospectively analyzed standard 12-lead electrocardiographic recordings of 124 consecutive patients in whom a CoreValve prosthesis was implanted. We examined 12-lead electrocardiogram before and after procedure along with one- and six-month follow-up. We documented QRS fragmentation and postprocedural rhythm disturbances. RESULTS: There was a significant increase in the frequency of left bundle branch block, (21.1 versus 0%, p<0.05) and the incidence of atrioventricular blocks requiring permanent pacing (21.1 versus 0%, p<0.05) following transcatheter aortic valve implantation in patients whose preprocedural electrocardiogram recordings revealed fragmented QRS compared to those without fragmented QRS. Based our collected data, the presence of QRS fragmentation in anterior derivations was the only independent factor associated with postprocedural rhythm disturbances (B-value 0.217; OR 0.805; 95%CI 0.136-4.78; p=0.004). CONCLUSION: Our data showed an increased risk for the development of new-onset left bundle branch block and atrioventricular blocks following transcatheter aortic valve implantation in patients whose baseline electrocardiogram recordings demonstrated QRS fragmentation.


Asunto(s)
Humanos , Estenosis de la Válvula Aórtica/cirugía , Marcapaso Artificial , Prótesis Valvulares Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estimulación Cardíaca Artificial , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Electrocardiografía
11.
Chinese Medical Journal ; (24): 2678-2684, 2021.
Artículo en Inglés | WPRIM | ID: wpr-921230

RESUMEN

BACKGROUND@#The past decade has witnessed an ever-increasing momentum of transcatheter aortic valve replacement (TAVR) and a subsequent paradigm shift in the contemporary management of severe aortic stenosis (AS). We conducted a multi-centric TAVR registry based on Chinese patients (the China Aortic valve tRanscatheter Replacement registrY [CARRY]) to delineate the clinical characteristics and outcomes of Chinese patients who underwent TAVR and compare the results between different valve types in different Chinese regions.@*METHODS@#CARRY is an all-comer registry of aortic valve disease patients undergoing TAVR across China and was designed as an observational study that retrospectively included all TAVR patients at each participating site. Seven hospitals in China participated in the CARRY, and 1204 patients from April 2012 to November 2020 were included. Categorical variables were compared using the chi-squared test, and continuous variables were analyzed using a t test or analysis of variance (ANOVA) test. The Kaplan-Meier curve was used to estimate the risk of adverse events during follow-up.@*RESULTS@#The mean age of the patients was 73.8 ± 6.5 years and 57.2% were male. The median Society of Thoracic Surgeon-Predicted Risk of Mortality score was 6.0 (3.7-8.9). Regarding the aortic valve, the proportion of bicuspid aortic valve (BAV) was 48.5%. During the hospital stay, the stroke rate was 0.7%, and the incidence of high-degree atrioventricular block indicating permanent pacemaker implantation was 11.0%. The in-hospital all-cause mortality rate was 2.2%. After 1 year, the overall mortality rate was 4.5%. Compared to patients with tricuspid aortic valve (TAV), those with BAV had similar in-hospital complication rates, but a lower incidence of in-hospital mortality (1.4% vs. 3.3%) and 1 year mortality (2.3% vs. 5.8%).@*CONCLUSIONS@#TAVR candidates in China were younger, higher proportion of BAV, and had lower rates of post-procedural complications and mortality than other international all-comer registries. Given the use of early generation valves in the majority of the population, patients with BAV had similar rates of complications, but lower mortality than those with TAV. These findings further propel the extension of TAVR in low-risk patients.@*TRIAL REGISTRATION@#https://www.chictr.org.cn/ (No. ChiCTR2000038526).


Asunto(s)
Anciano , Anciano de 80 o más Años , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
Arq. bras. cardiol ; 115(4): 680-687, out. 2020. graf
Artículo en Portugués | SES-SP, LILACS | ID: biblio-1131356

RESUMEN

Resumo Fundamento O implante valvar aórtico percutâneo (TAVR, do inglês Transcatheter Aortic Valve Replacement) reduz a mortalidade de pacientes portadores de estenose aórtica grave. O conhecimento da distribuição da pressão e tensão de cisalhamento na parede aórtica pode ajudar na identificação de regiões críticas, onde o processo de remodelamento aórtico pode ocorrer. Neste trabalho é apresentado um estudo de simulação computacional da influência do posicionamento do orifício valvar protético na hemodinâmica na raiz de aorta e segmento ascendente. Objetivos A presente análise apresenta um estudo da variação do padrão de fluxo devido a alterações no ângulo do orifício valvar. Métodos Um modelo tridimensional foi gerado a partir do exame de angiotomografia computadorizada da aorta de um paciente que foi submetido ao procedimento de TAVR. Diferentes vazões de fluxo foram impostas através do orifício valvar. Resultados Pequenas variações no ângulo de inclinação causaram mudanças no padrão de fluxo, com deslocamento na posição dos vórtices, na distribuição de pressão e no local de alta tensão cisalhante na parede aórtica. Conclusão Essas características hemodinâmicas podem ser importantes no processo de remodelamento aórtico e distribuição de tensão, além de auxiliar, em um futuro próximo, a otimização do posicionamento da prótese valvar percutânea. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Backgroud Transcatheter aortic valve replacement (TAVR) can reduce mortality among patients with aortic stenosis. Knowledge of pressure distribution and shear stress at the aortic wall may help identify critical regions, where aortic remodeling process may occur. Here a numerical simulation study of the influence of positioning of the prosthetic valve orifice on the flow field is presented. Objective The present analysis provides a perspective of great variance on flow behavior due only to angle changes. Methods A 3D model was generated from computed tomography angiography of a patient who had undergone a TAVR. Different mass flow rates were imposed at the inlet valve. Results Small variations of the tilt angle could modify the nature of the flow, displacing the position of the vortices, and altering the prerssure distribution and the location of high wall shear stress. Conclusion These hemodynamic features may be relevant in the aortic remodeling process and distribution of the stress mapping and could help, in the near future, the optimization of the percutaneous prosthesis implantation. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Asunto(s)
Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Aorta , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Angiografía por Tomografía Computarizada , Hemodinámica
13.
Rev. bras. cir. cardiovasc ; 35(4): 504-511, July-Aug. 2020. tab, graf
Artículo en Inglés | LILACS, SES-SP | ID: biblio-1137287

RESUMEN

Abstract Introduction: Recently, the clinical significance of mild paravalvular aortic regurgitation (PAR) has been evaluated and suggested that it can be predictor of clinical outcomes. In our study, we aimed to investigate the interaction of aortic pulse wave velocity (PWV) and mild PAR and their effects on the functional status of patients after transcatheter aortic valve implantation (TAVI). Methods: A total of 109 consecutive patients with symptomatic severe aortic stenosis were enrolled prospectively. After TAVI procedure, they were divided in to three groups according to PAR and PWV measurements. Patients without PAR were defined as the NonePAR group (n=60), patients with mild PAR and normal PWV were defined as the MildPAR-nPWV group (n=23), and patients with mild PAR and high PWV were defined as the MildPAR-hPWV group (n=26). Results: Compared with other groups, the MildPAR-hPWV group was older (P<0.001), hypertensive (P=0.015), and had a higher pulse pressure (P=0.018). In addition to PWV, this group had lower aortic regurgitation index (ARI) (P=0.010) and higher rate of New York Heart Association (NYHA) class II (at least) patients (P<0.001) in 30-day follow-up period. On multivariate regression analysis, the MildPARhPWV group (odds ratio=1.364, 95% confidence interval 1.221-1.843; P=0.011) as well as N-terminal-pro-brain natriuretic peptide levels and ARI were independently related with 30-day functional NYHA classification. However, NonePAR or MildPAR-nPWV group was not an independent predictor of early functional status. Conclusion: It was concluded that high PWV may adversely affect early functional status in patients with mild PAR in contrast to normal values following TAVI.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad , Inhibidores de la Enzima Convertidora de Angiotensina , Resultado del Tratamiento , Antagonistas de Receptores de Angiotensina , Análisis de la Onda del Pulso
15.
Rev. chil. cardiol ; 38(3): 173-181, dic. 2019. tab, graf
Artículo en Español | LILACS | ID: biblio-1058060

RESUMEN

RESUMEN INTRODUCCIÓN: En pacientes con estenosis Aórtica (EA) severa sintomática, el implante de válvula aórtica percutánea transcatéter (TAVI) por vía transfemoral constituye el estándar de tratamiento en aquellos de riesgo quirúrgico intermedio o alto. El uso de un abordaje minimalista ha demostrado ser seguro y efectivo, si bien no existen reportes sobre la realidad nacional Métodos: Estudio descriptivo sobre la experiencia con pacientes sometidos al implante de TAVI bajo un protocolo minimalista en Unidad de Cardiología Intervencional y Hemodinamia del Hospital Sótero del Río desde Enero de 2018. Se analizaron las variables clínicas de los pacientes y del procedimiento así como desenlaces clínicos intrahospitalarios y seguimiento alejado. Resultados: Entre Enero 2018 hasta Abril 2019, un total de 10 pacientes fueron sometidos al implante de TAVI por vía transfemoral. El score STS-PROM promedio fue de 7,1. Se logró un implante exitoso en el 100% de los casos con un gradiente medio residual de 8 mmHg y sin leak moderado a severo en ningún paciente. No hubo eventos cerebrovasculares isquémicos perioperatorios ni muerte en este grupo. Se requirió implante de marcapasos definitivo en 3 pacientes y un paciente presentó hematoma femoral perioperatorio que requirió transfusión de glóbulos rojos. La mediana de la estadía hospitalaria fue de 2 días. Conclusiones: El uso de una estrategia minimalista para el implante de TAVI en nuestra realidad nacional es seguro y aplicable. Los resultados perioperatorios y a 30 días fueron comparables a los descritos en experiencias internacionales.


ABSTRACT BACKGROUND: In patients with symptomatic severe aortic stenosis, transcatheter percutaneous aortic valve implant (TAVI) is the standard treatment in those with intermediate or high surgical risk. The use of a minimalist approach has proven to be safe and effective, although there are no reports on the national reality Methods: Descriptive study on the experience with patients undergoing TAVI implantation under a minimalist protocol at the Interventional Cardiology and Hemodynamics Unit of the Hospital Sótero del Río since January 2018. Clinical characteristics of the patients and the procedure were analyzed as well as intrahospital outcomes and at 30-days follow up. Results: Between January 2018 and April 2019, a total of 10 patients underwent TAVI implantation by transfemoral approach in our institution. The average STS-PROM score was 7.1. A successful implant was achieved in 100% of cases with an average residual gradient of 8 mmHg and no moderate to severe leak in any patient. There were no perioperative ischemic cerebrovascular events nor death in this group. A definitive pacemaker implant was required in 3 patients and one patient developed femoral hematoma that required red blood cell transfusion. The median hospital stay was 2 days. Conclusions: The use of a minimalist strategy for TAVI implantation in our national reality is safe and applicable. Immediate results and at 30-days follow up were comparable to those described in international experiences.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Implantación de Prótesis de Válvulas Cardíacas/métodos , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica , Complicaciones Posoperatorias/terapia , Epidemiología Descriptiva , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación
16.
Arq. bras. cardiol ; 113(6): 1151-1154, Dec. 2019. graf
Artículo en Inglés | LILACS | ID: biblio-1055066

RESUMEN

Abstract Transcatheter aortic valve implantation (TAVI) is an established treatment for severe aortic stenosis (AS) in patients with elevated surgical risk. Concomitant coronary artery disease affects 55-70% of patients with severe AS. Percutaneous coronary intervention in patients with TAVI can be challenging. We report a case of acute coronary obstruction immediately following transapical TAVI deployment requiring emergent rotational atherectomy.


Resumo O implante valvar aórtico transcateter (TAVI) é um tratamento estabelecido para estenose aórtica grave (EA) em pacientes com risco cirúrgico elevado. Doença arterial coronariana concomitante afeta 55-70% dos pacientes com EA grave. A intervenção coronária percutânea em pacientes com TAVI pode ser um desafio. Relatamos um caso de obstrução coronariana aguda imediatamente após o implante de TAVI transapical, exigindo aterectomia rotacional emergencial.


Asunto(s)
Humanos , Masculino , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Intervención Coronaria Percutánea/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Angiografía Coronaria , Aterectomía Coronaria/métodos
18.
Rev. bras. cir. cardiovasc ; 34(3): 361-365, Jun. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1013459

RESUMEN

Abstract Prosthesis-patient mismatch (PPM) after surgical aortic valve replacement (SAVR) is an issue that has been overlooked (not to say neglected). Cardiac surgeons must bear in mind that this is a real problem that we must tackle. The purpose of this paper is to be a wake-up call to the surgical community by giving a brief overview of what PPM is, its incidence and impact on the outcomes. We also discuss the increasing role played by imaging for predicting and assessing PPM after SAVR (with which surgeons must become more acquainted) and, finally, we present some options to avoid PPM after the surgical procedure.


Asunto(s)
Humanos , Falla de Prótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Factores de Riesgo , Insuficiencia del Tratamiento , Medición de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
19.
Rev. bras. cir. cardiovasc ; 34(3): 318-326, Jun. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1013462

RESUMEN

Abstract Objectives: This study sought to evaluate the impact of prosthesis-patient mismatch (PPM) on the risk of early-term mortality after transcatheter aortic valve implantation (TAVI). Methods: Databases (Medical Literature Analysis and Retrieval System Online [MEDLINE], Excerpta Medica dataBASE [EMBASE], Cochrane Controlled Trials Register [CENTRAL/CCTR], ClinicalTrials.gov, Scientific Electronic Library Online [SciELO], Latin American and Caribbean Literature on Health Sciences [LILACS], and Google Scholar) were searched for studies published until February 2019. PPM after TAVI was defined as moderate if the indexed effective orifice area (iEOA) was between 0.85 cm2/m2 and 0.65 cm2/m2 and as severe if iEOA ≤ 0.65 cm2/m2. Results: The search yielded 1,092 studies for inclusion. Of these, 18 articles were analyzed, and their data extracted. The total number of patients included who underwent TAVI was 71,106. The incidence of PPM after TAVI was 36.3% (25,846 with PPM and 45,260 without PPM). One-year mortality was not increased in patients with any PPM (odds ratio [OR] 1.021, 95% confidence interval [CI] 0.979-1.065, P=0.338) neither in those with moderate PPM (OR 0.980, 95% CI 0.933-1.029, P=0.423). Severe PPM was separately associated with high risk (OR 1.109, 95% CI 1.041-1.181, P=0.001). Conclusion: The presence of severe PPM after TAVI increased early-term mortality. Although moderate PPM seemed harmless, the findings of this study cannot not rule out the possibility of it being detrimental, since there are other registries that did not address this issue yet.


Asunto(s)
Humanos , Falla de Prótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Índice de Severidad de la Enfermedad , Factores de Riesgo , Insuficiencia del Tratamiento , Medición de Riesgo
20.
Rev. bras. cir. cardiovasc ; 33(6): 559-566, Nov.-Dec. 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-977467

RESUMEN

Abstract Objective: To evaluate the predictive value of mean perfusion pressure (mPP) in the development of acute kidney injury (AKIN) after transcatheter aortic valve implantation (TAVI). Methods: One hundred and forty seven consecutive patients with aortic stenosis (AS) were evaluated for this study and 133 of them were included. Mean arterial pressure (mAP) and central venous pressure (CVP) were used to calculate mPP before TAVI procedure (mPP = mAP-CVP). The occurrence of AKIN was evaluated with AKIN classification according to the Valve Academic Research Consortium-2 recommendations. The patients were divided into two groups according to the receiver operating characteristic (ROC) analysis of their mPP levels (high-risk group and low-risk group). Results: The AKIN prevalence was 22.6% in this study population. Baseline serum creatinine level, glomerular filtration rate, amount of contrast medium, and the level of mPP were determined as predictive factors for the development of AKIN. Conclusion: The occurrence of AKIN is associated with increased morbidity and mortality rates in patients with TAVI. In addition to the amount of contrast medium and basal kidney functions, our study showed that lower mPP was strongly associated with development of AKIN after TAVI.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias/etiología , Presión Sanguínea , Prótesis Valvulares Cardíacas , Lesión Renal Aguda/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Complicaciones Posoperatorias/mortalidad , Tasa de Supervivencia , Factores de Riesgo , Curva ROC , Medios de Contraste , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Chipre/epidemiología , Lesión Renal Aguda/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA