Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 4 de 4
Filtre
Ajouter des filtres








Gamme d'année
1.
Pesqui. bras. odontopediatria clín. integr ; 24: e220192, 2024. tab, graf
Article Dans Anglais | LILACS, BBO | ID: biblio-1550593

Résumé

ABSTRACT Objective: To investigate the effects of two different dentifrice fluoride concentrations on the color stability of the composite. Material and Methods: Twenty-seven specimens (2×4×5 mm) each of microfilled (Gradia, GC, Japan) and nanohybrid (Grandio, VOCO, Germany) composites were prepared. The specimens were randomly divided into six groups (control, Fluoflor caries protection toothpaste with 1450ppm Fluoride (EXW, France), and Fluoflor kids toothpaste with 500ppm Fluoride (EXW, France) (n = 9). The specimens were immersed in a mixture of artificial saliva and toothpaste in a ratio of 1:3 and applied for 60 seconds every 12 hours for 42 days. The control samples were incubated in artificial saliva at 37°C. Primary and secondary color measurements were performed using color parameters (L∗a∗b) with a spectrophotoshade (MHT Optic Research AG, Niederhasli, Switzerland). Data were analyzed using a two-way analysis of variance at a significance level of 0.05. Results: According to the two-way ANOVA analysis, there was no significant difference in color change between the composites and no difference in the level of discoloration between different fluoride concentrations(p>0.05). Also, None of the dentifrices caused clinically significant color changes(∆E˂3.3). Conclusion: No clinically unacceptable color changes were observed in the microfilled and nanofilled composites with different concentrations of fluoride toothpaste.


Sujets)
Pâtes dentifrices/composition chimique , Couleur , Résines composites/composition chimique , Fluorures/composition chimique , Techniques in vitro/méthodes , Analyse de variance , Dentifrices
2.
Pesqui. bras. odontopediatria clín. integr ; 22: e210185, 2022. tab, graf
Article Dans Anglais | LILACS, BBO | ID: biblio-1422268

Résumé

Abstract Objective: To compare the cytotoxicity level of a new calcium silicate-based resin cement (TheraCem) with two commonly used cements, including a conventional self-adhesive resin cement (Panavia SA) and a resinmodified glass ionomer cement (FujiCem2), on the human gingival fibroblast cells after 24 and 48 hours. Material and Methods: Twelve discs of each cement type were fabricated. The extract of cement disks was made by incubating them in the cell medium. Human gingival fibroblast cells were cultured and exposed to cement extracts for 24 h and 48 h. MTT assay was performed on extracts and optical density and cell viability rates were calculated by the spectrophotometer device at 570 nm. Data were analyzed using ANOVA and Tukey HSD tests. Results: The cell viability rates after 24 hours and 48 hours were as follows: TheraCem: 89.24% and 85.46%, Panavia SA: 49.51% and 46.57% and FujiCem2: 50.63% and 47.36%. TheraCem represented the highest cell viability rate. However, no significant difference was noted between Panavia SA and FujiCem2. Time had no significant effect on cell viability. Conclusion: TheraCem exhibited the best results among three tested cements and was considered non-toxic. Panavia SA and FujiCem2 were not significantly different regarding the cell viability rate. Time had no significant effect on the cytotoxicity level of cements (AU).


Sujets)
Calcarea Silicata , Céments résine , Fibroblastes/microbiologie , Ciment ionomère au verre , Survie cellulaire , Spectrophotomètres , Analyse de variance
3.
Braz. j. oral sci ; 19: e208556, jan.-dez. 2020. tab
Article Dans Anglais | BBO, LILACS | ID: biblio-1152139

Résumé

Aim: Self-adhesive flowable composite resins have been recently introduced to the market. Degree of conversion (DC) and water sorption (WS) are two important parameters affecting the properties of restorative materials. This study aimed to assess the DC and WS of a self-adhesive flowable composite resin in comparison with two conventional flowable composite resins. Methods: Vertise Flow (VF) self-adhesive and Tetric-N Flow (TF) and Grandio Flow (GF) conventional flowable composites were evaluated in this in vitro, experimental study. The DC (n=3) was determined by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR). The WS (n=7) was measured after 7 days of immersion in artificial saliva accordingto ISO 4049specifications. Data were analyzed by one-way ANOVA and a post-hoc test (p<0.05). Results: VF showed the highest DC percentage (84.3%) followed by GF (72.79%) and TF (68.7%). The latter two had no significant difference (p=0.8). WS was the highest in VF (55.2 µg/mm3), and the two conventional flowable composites had a significant difference in WS (19.5 µg/mm3 in TF and 11 µg/mm3 in GF; p<0.001). Conclusions: Flowable composite resins had significant differences in DC and WS, and VF demonstrated the highest DC and WS


Sujets)
Résines composites , Absorption , Polymérisation
4.
Braz. j. oral sci ; 14(2): 166-170, Apr.-June 2015. tab, ilus
Article Dans Anglais | LILACS | ID: lil-755044

Résumé

Despite the increasing demand for fiber-reinforced composite (FRC) posts, their bonding to root canals is still subject to debate. Endodontic sealers may affect the bond strength between fiber posts and root canal dentin. Aim: To compare the effects of different sealers on fiber post bond strength. Methods: Sixty teeth were divided into 4 groups according to obturation method: GI, gutta-percha without any sealers; GII, gutta-percha and AH26 resin-based sealer; GIII, RealSeal point and RealSeal resin-based sealer, GIV, Guttaflow. Fiber posts were cemented into root canals. Specimens were sectioned, and the bond strength was measured in the middle area. The failure mode was evaluated. Data were analyzed by one-way ANOVA and post hoc test. Results: The highest bond strength was observed in the control group (2.95±1.12), and the least was in the Guttaflow group (1.15±0.78). There was a significant difference between bond strengths of the control and Guttaflow groups and between AH26 and Guttaflow groups (p<0.05). The failure mode was mainly adhesive between dentin and resin cement in all groups. Conclusions: Sealers may have a negative effect on the bond strength of fiber posts to root canal dentin.


Sujets)
Humains , Mâle , Femelle , Pulpe dentaire , Cavité pulpaire de la dent , Dentine , Endodontie , Produits d'obturation des canaux radiculaires , Obturation de canal radiculaire
SÉLECTION CITATIONS
Détails de la recherche