Braz. j. microbiol ; 43(2): 429-431, Apr.-June 2012. graf, tab
Article Dans Anglais | LILACS | ID: lil-644455

Résumé

The aim of this study was to compare the PSPT standardized in-house as an alternative to MPT for potency assays of pertussis component. Statistical analyses have showed similar pertussis potency values when PSPT was compared to MPT. Significant correlation between the potency results obtained by in vivo and in vitro assays was also been observed. Results by PSPT have demonstrated reproducibility and accuracy for potency pertussis control and this approach has been considered promising for use at least during the steps of production.


Sujets)
Animaux , Rats , Bordetella pertussis/immunologie , Bordetella pertussis/isolement et purification , Coqueluche/immunologie , Techniques et procédures diagnostiques , Technique EMIT , Méthodes , Rats , Vaccins
2.
Mem. Inst. Oswaldo Cruz ; 103(7): 711-718, Nov. 2008. ilus, tab
Article Dans Anglais | LILACS | ID: lil-498381

Résumé

A randomized, double-blinded study evaluating the immunogenicity, safety and consistency of production of a combined diphtheria-tetanus-pertussis-Haemophilus influenzae type b vaccine entirely produced in Brazil by Bio-Manguinhos and Instituto Butantan (DTP/Hib-BM) was undertaken. The reference vaccine had the same DTP vaccine but the Hib component was produced using purified materials supplied by GlaxoSmithKline (DTP/Hib-GSK), which is registered and has supplied the Brazilian National Immunization Program for over more than five years. One thousand infants were recruited for the study and received vaccinations at two, four and six months of age. With respect to immunogenicity, the vaccination protocol was followed in 95.6 percent and 98.4 percent of infants in the DTP/Hib-BM and DTP/Hib-GSK groups, respectively. For the Hib component of the study, there was 100 percent seroprotection (>0.15 µg/mL) with all three lots of DTP/Hib-BM and DTP/Hib-GSK. The geometric mean titer (GMT) was 9.3 µg/mL, 10.3 µg/mL and 10.3 µg/mL for lots 1, 2 and 3 of DTP/Hib-BM, respectively, and the GMT was 11.3 g/mL for DTP/Hib-GSK. For diphtheria, tetanus and pertussis, seroprotection was 99.7 percent, 100 percent and 99.9 percent, respectively, for DTP/Hib-BM, three lots altogether and 99.2 percent, 100 percent and 100 percent for DTP/Hib-GSK. GMTs were similar across all lots and vaccines. Adverse events rates were comparable among the vaccine groups. The Brazilian DTP/Hib vaccine demonstrated an immunogenicity and reactogenicity profile similar to that of the reference vaccine.


Sujets)
Femelle , Humains , Nourrisson , Mâle , Vaccin diphtérie-tétanos-coqueluche/immunologie , Diphtérie/prévention et contrôle , Infections à Haemophilus/prévention et contrôle , Vaccins anti-Haemophilus/immunologie , Tétanos/prévention et contrôle , Coqueluche/prévention et contrôle , Bordetella pertussis/immunologie , Clostridium tetani/immunologie , Corynebacterium diphtheriae/immunologie , Méthode en double aveugle , Vaccin diphtérie-tétanos-coqueluche/administration et posologie , Vaccin diphtérie-tétanos-coqueluche/effets indésirables , Vaccins anti-Haemophilus/administration et posologie , Vaccins anti-Haemophilus/effets indésirables , Haemophilus influenzae type B/immunologie , Facteurs temps