Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 19 de 19
Filtre
1.
The Korean Journal of Orthodontics ; : 77-85, 2021.
Article Dans Anglais | WPRIM | ID: wpr-896061

Résumé

Objective@#To evaluate the accuracy of a multi-stage convolutional neural network (CNN) model-based automated identification system for posteroanterior (PA) cephalometric landmarks. @*Methods@#The multi-stage CNN model was implemented with a personal computer. A total of 430 PA-cephalograms synthesized from cone-beam computed tomography scans (CBCT-PA) were selected as samples. Twenty-three landmarks used for Tweemac analysis were manually identified on all CBCT-PA images by a single examiner. Intra-examiner reproducibility was confirmed by repeating the identification on 85 randomly selected images, which were subsequently set as test data, with a two-week interval before training. For initial learning stage of the multi-stage CNN model, the data from 345 of 430 CBCT-PA images were used, after which the multi-stage CNN model was tested with previous 85 images. The first manual identification on these 85 images was set as a truth ground. The mean radial error (MRE) and successful detection rate (SDR) were calculated to evaluate the errors in manual identification and artificial intelligence (AI) prediction. @*Results@#The AI showed an average MRE of 2.23 ± 2.02 mm with an SDR of 60.88% for errors of 2 mm or lower. However, in a comparison of the repetitive task, the AI predicted landmarks at the same position, while the MRE for the repeated manual identification was 1.31 ± 0.94 mm. @*Conclusions@#Automated identification for CBCT-synthesized PA cephalometric landmarks did not sufficiently achieve the clinically favorable error range of less than 2 mm. However, AI landmark identification on PA cephalograms showed better consistency than manual identification.

2.
The Korean Journal of Orthodontics ; : 231-240, 2021.
Article Dans Anglais | WPRIM | ID: wpr-896053

Résumé

Objective@#This outcome analysis study evaluated the actual positions of the orthodontic miniplate and miniplate anchoring screws (MPASs) and the risk factors affecting adjacent anatomic structures after miniplate placement in the mandibular incisal area. @*Methods@#Cone-beam computed tomographic images of 97 orthodontic miniplates and their 194 MPASs (diameter, 1.5 mm; length, 4 mm) in patients whose miniplates provided sufficient clinical stability for orthodontic treatment were retrospectively reviewed. For evaluating the actual positions of the miniplates and analyzing the risk factors, including the effects on adjacent roots, MPAS placement height (PH), placement depth (PD), plate angle (PA), mental fossa angle (MA), and root proximity were assessed using the paired t-test, analysis of variance, and generalized linear model and regression analyses. @*Results@#The mean PDs of MPASs at positions 1 (P1) and 2 (P2) were 2.01 mm and 2.23 mm, respectively. PA was significantly higher in the Class III malocclusion group than in the other groups. PH was positively correlated with MA and PD at P1. Of the 97 MPASs at P1, 49 were in the no-root area and 48 in the dentulous area; moreover, 19 showed a degree of root contact (19.6%) without root perforation. All MPASs at P2 were in the no-root area. @*Conclusions@#Positioning the miniplate head approximately 1 mm lower than the mucogingival junction is highly likely to provide sufficient PH for the P1-MPASs to be placed in the no-root area.

3.
The Korean Journal of Orthodontics ; : 260-269, 2021.
Article Dans Anglais | WPRIM | ID: wpr-896050

Résumé

Objective@#To identify the most favorable sites that optimize the initial stability and survival rate of orthodontic mini-implants, this study measured hard and soft tissue thicknesses in the median and paramedian regions of the palate using cone-beam computed tomography (CBCT) and determined possible sexand age-related differences in these thicknesses. @*Methods@#The study sample comprised CBCT images of 189 healthy subjects. The sample was divided into four groups according to age. A grid area was set for the measurement of hard and soft tissue thicknesses in the palate. Vertical lines were marked at intervals of 0, 1.5, and 3.0 mm lateral to the midpalatal suture, while horizontal lines were marked at 2-mm intervals up to 24 mm from the posterior margin of the incisive foramen. Measurements were made at 65 points of intersection between the horizontal and vertical lines. @*Results@#The palatal hard tissue thickness decreased from the anterior to the posterior region, with a decrease in the medial-to-lateral direction in the middle and posterior regions. While the soft tissue was rather thick around the lateral aspects of the palatal arch, it formed a constant layer that was only 1–2-mm thick throughout the palate. Statistically significant differences were observed according to sex and age. @*Conclusions@#The anterolateral palate as well as the midpalatal suture seem to be the most favorable sites for insertion of orthodontic mini-implants. The thickness of the palate differed by age and sex; these differences should be considered while planning the placement of orthodontic mini-implants.

4.
The Korean Journal of Orthodontics ; : 77-85, 2021.
Article Dans Anglais | WPRIM | ID: wpr-903765

Résumé

Objective@#To evaluate the accuracy of a multi-stage convolutional neural network (CNN) model-based automated identification system for posteroanterior (PA) cephalometric landmarks. @*Methods@#The multi-stage CNN model was implemented with a personal computer. A total of 430 PA-cephalograms synthesized from cone-beam computed tomography scans (CBCT-PA) were selected as samples. Twenty-three landmarks used for Tweemac analysis were manually identified on all CBCT-PA images by a single examiner. Intra-examiner reproducibility was confirmed by repeating the identification on 85 randomly selected images, which were subsequently set as test data, with a two-week interval before training. For initial learning stage of the multi-stage CNN model, the data from 345 of 430 CBCT-PA images were used, after which the multi-stage CNN model was tested with previous 85 images. The first manual identification on these 85 images was set as a truth ground. The mean radial error (MRE) and successful detection rate (SDR) were calculated to evaluate the errors in manual identification and artificial intelligence (AI) prediction. @*Results@#The AI showed an average MRE of 2.23 ± 2.02 mm with an SDR of 60.88% for errors of 2 mm or lower. However, in a comparison of the repetitive task, the AI predicted landmarks at the same position, while the MRE for the repeated manual identification was 1.31 ± 0.94 mm. @*Conclusions@#Automated identification for CBCT-synthesized PA cephalometric landmarks did not sufficiently achieve the clinically favorable error range of less than 2 mm. However, AI landmark identification on PA cephalograms showed better consistency than manual identification.

5.
The Korean Journal of Orthodontics ; : 231-240, 2021.
Article Dans Anglais | WPRIM | ID: wpr-903757

Résumé

Objective@#This outcome analysis study evaluated the actual positions of the orthodontic miniplate and miniplate anchoring screws (MPASs) and the risk factors affecting adjacent anatomic structures after miniplate placement in the mandibular incisal area. @*Methods@#Cone-beam computed tomographic images of 97 orthodontic miniplates and their 194 MPASs (diameter, 1.5 mm; length, 4 mm) in patients whose miniplates provided sufficient clinical stability for orthodontic treatment were retrospectively reviewed. For evaluating the actual positions of the miniplates and analyzing the risk factors, including the effects on adjacent roots, MPAS placement height (PH), placement depth (PD), plate angle (PA), mental fossa angle (MA), and root proximity were assessed using the paired t-test, analysis of variance, and generalized linear model and regression analyses. @*Results@#The mean PDs of MPASs at positions 1 (P1) and 2 (P2) were 2.01 mm and 2.23 mm, respectively. PA was significantly higher in the Class III malocclusion group than in the other groups. PH was positively correlated with MA and PD at P1. Of the 97 MPASs at P1, 49 were in the no-root area and 48 in the dentulous area; moreover, 19 showed a degree of root contact (19.6%) without root perforation. All MPASs at P2 were in the no-root area. @*Conclusions@#Positioning the miniplate head approximately 1 mm lower than the mucogingival junction is highly likely to provide sufficient PH for the P1-MPASs to be placed in the no-root area.

6.
The Korean Journal of Orthodontics ; : 260-269, 2021.
Article Dans Anglais | WPRIM | ID: wpr-903754

Résumé

Objective@#To identify the most favorable sites that optimize the initial stability and survival rate of orthodontic mini-implants, this study measured hard and soft tissue thicknesses in the median and paramedian regions of the palate using cone-beam computed tomography (CBCT) and determined possible sexand age-related differences in these thicknesses. @*Methods@#The study sample comprised CBCT images of 189 healthy subjects. The sample was divided into four groups according to age. A grid area was set for the measurement of hard and soft tissue thicknesses in the palate. Vertical lines were marked at intervals of 0, 1.5, and 3.0 mm lateral to the midpalatal suture, while horizontal lines were marked at 2-mm intervals up to 24 mm from the posterior margin of the incisive foramen. Measurements were made at 65 points of intersection between the horizontal and vertical lines. @*Results@#The palatal hard tissue thickness decreased from the anterior to the posterior region, with a decrease in the medial-to-lateral direction in the middle and posterior regions. While the soft tissue was rather thick around the lateral aspects of the palatal arch, it formed a constant layer that was only 1–2-mm thick throughout the palate. Statistically significant differences were observed according to sex and age. @*Conclusions@#The anterolateral palate as well as the midpalatal suture seem to be the most favorable sites for insertion of orthodontic mini-implants. The thickness of the palate differed by age and sex; these differences should be considered while planning the placement of orthodontic mini-implants.

7.
Imaging Science in Dentistry ; : 125-132, 2020.
Article | WPRIM | ID: wpr-835423

Résumé

Purpose@#The positions of the mandibular foramen (MnF) and the lingula affect the success rate of inferior alveolar nerve block. The objective of this study was to investigate aspects of the MnF and the lingula relevant for mandibular block anesthesia using cone-beam computed tomography (CBCT). @*Materials and Methods@#Fifty CBCT scans were collected from a picture archiving and communications system. All scans were taken using an Alphard Vega 3030 (Asahi Roentgen Co. Ltd., Kyoto, Japan). Fifty-eight MnFs of 30 subjects were included in the study. The position of the MnF, the size of the MnF, the position of the lingula, the size of the lingula, and the shape of the lingula were measured and recorded. All data were statistically analyzed at a significance level of p<0.05. @*Results@#The position of MnF was 0.1 mm and 0.8 mm below the occlusal plane in males and females, respectively. The horizontal position of the MnF was slightly anterior to the center of the ramus in males and in the center in females (p<0.05). The vertical position of the MnF was lower in females than in males (p<0.05). The MnF was an oval shape with a longer anteroposterior dimension. The height of the lingula was 9.3 mm in males and 8.2 mm in females. The nodular type was the most common shape of the lingula, followed by the triangular, truncated, and assimilated types. @*Conclusion@#CBCT provided useful information about the MnF and lingula. This information could improve the success rate of mandibular blocks.

8.
Imaging Science in Dentistry ; : 9-14, 2020.
Article Dans Anglais | WPRIM | ID: wpr-811169

Résumé

PURPOSE: The purpose of this study was to evaluate vertical bone loss and alveolar bone thickness in the maxillary and mandibular incisors of patients with skeletal class III malocclusion. This study also aimed to evaluate the periodontal condition of class III malocclusion patients who had not undergone orthodontic treatment.MATERIALS AND METHODS: The sample included cone-beam computed tomography scans of 24 Korean subjects (3 male and 21 female). Alveolar bone thickness (ABT), alveolar bone area (ABA), alveolar bone loss (ABL), and fenestration of the maxillary and mandibular incisors were measured using 3-dimensional imaging software.RESULTS: All incisors displayed an ABT of less than 1.0 mm from the labial surface to root level 7 (70% of the root length). A statistically significant difference was observed between the mandibular labial and lingual ABAs and between the maxillary labial and mandibular labial ABAs. The lingual ABA of the mandibular lateral incisors was larger than that of the mandibular central incisors. ABL was severe on the labial surface. A statistically significant difference was observed between the maxillary and mandibular labial ABL values(21.8% and 34.4%, respectively). Mandibular lingual ABL (27.6%) was significantly more severe than maxillary lingual ABL (18.3%) (P<0.05). Eighty-two fenestrations were found on the labial surfaces of the incisors, while only 2 fenestrations were observed on the lingual surfaces. Fenestrations were most commonly observed at root level 6.CONCLUSION: Careful evaluation is needed before orthodontic treatment to avoid iatrogenic damage of periodontal support when treating patients with class III malocclusion.

9.
Imaging Science in Dentistry ; : 301-306, 2019.
Article Dans Anglais | WPRIM | ID: wpr-785810

Résumé

PURPOSE: This report presents a procedure for performing power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow and illustrates its application to practical patient cases.MATERIALS AND METHODS: The salivary gland was scanned using ultrasound equipment (GE LOGIQ5 Expert® device; GE Medical Systems, Milwaukee, WI, USA) to identify pathological findings related to the patient's chief complaint. To identify the orifice of the main duct, it should be cannulated using a lacrimal dilator. After inserting the catheter into the cannulated main duct, the position of the catheter within the duct was confirmed by ultrasound. A contrast agent was injected until the patient felt fullness, and ultrasound (B-mode) was used to confirm whether the contrast agent filled the main canal and secondary and tertiary ducts. Then, power Doppler ultrasound was performed to determine whether the salivary gland had increased blood flow.RESULTS: In 2 cases in this report, a power Doppler ultrasound scan showed a significant increase in blood flow after contrast medium injection, which was not observed on a preoperative scan.CONCLUSION: Power Doppler ultrasound was found to be a simple, safe, and effective tool for real-time sialography monitoring.


Sujets)
Humains , Cathéters , Glandes salivaires , Sialographie , Échographie , Vasodilatation
10.
Imaging Science in Dentistry ; : 229-234, 2019.
Article Dans Anglais | WPRIM | ID: wpr-764002

Résumé

Central odontogenic fibroma (COF) is defined as a fibroblastic odontogenic tumor characterized by varying density of the tooth epithelium. It is an extremely rare benign neoplasm that occurs in the maxilla and the mandible; only a few reports of COF are available in the literature. Diagnosis of the lesion based only on the radiological features of COF is difficult due to variation in the findings regarding this condition. This report describes 2 clinical cases of middle-aged women with COF. Clinical examination revealed palatal mucosal depression; additionally, oral examination, as well as panoramic radiographs, intraoral radiographs, and computed tomography scans, revealed severe root resorption. This report highlights the clinical and radiological imaging features of COF, with the goal of enabling straightforward differential diagnosis of the lesion by the clinician and thereby appropriate treatment of the patient.


Sujets)
Femelle , Humains , Dépression , Diagnostic , Diagnostic différentiel , Diagnostic buccal , Épithélium , Fibroblastes , Fibrome , Mandibule , Maxillaire , Tumeurs odontogènes , Rhizalyse , Dent
11.
Imaging Science in Dentistry ; : 111-119, 2018.
Article Dans Anglais | WPRIM | ID: wpr-740372

Résumé

PURPOSE: This study was conducted to evaluate the accuracy of linear measurements of 3-dimensional (3D) images generated by cone-beam computed tomography (CBCT) and facial scanning systems, and to assess the effect of scanning parameters, such as CBCT exposure settings, on image quality. MATERIALS AND METHODS: CBCT and facial scanning images of an anthropomorphic phantom showing 13 soft-tissue anatomical landmarks were used in the study. The distances between the anatomical landmarks on the phantom were measured to obtain a reference for evaluating the accuracy of the 3D facial soft-tissue images. The distances between the 3D image landmarks were measured using a 3D distance measurement tool. The effect of scanning parameters on CBCT image quality was evaluated by visually comparing images acquired under different exposure conditions, but at a constant threshold. RESULTS: Comparison of the repeated direct phantom and image-based measurements revealed good reproducibility. There were no significant differences between the direct phantom and image-based measurements of the CBCT surface volume-rendered images. Five of the 15 measurements of the 3D facial scans were found to be significantly different from their corresponding direct phantom measurements (P < .05). The quality of the CBCT surface volume-rendered images acquired at a constant threshold varied across different exposure conditions. CONCLUSION: These results proved that existing 3D imaging techniques were satisfactorily accurate for clinical applications, and that optimizing the variables that affected image quality, such as the exposure parameters, was critical for image acquisition.


Sujets)
Anthropométrie , Tomodensitométrie à faisceau conique , Précision de la mesure dimensionnelle , Imagerie tridimensionnelle
12.
Imaging Science in Dentistry ; : 59-65, 2018.
Article Dans Anglais | WPRIM | ID: wpr-740359

Résumé

Osseointegrated implants are now commonplace in contemporary dentistry. However, a number of complications can occur around dental implants, including peri-implantitis, maxillary sinusitis, osteomyelitis, and neoplasms. There have been several reports of a malignant neoplasm occurring adjacent to a dental implant. In this report, we describe 2 such cases. One case was that of a 75-year-old man with no previous history of malignant disease who developed a solitary plasmacytoma around a dental implant in the left posterior mandible, and the other was that of a 43-year-old man who was diagnosed with squamous cell carcinoma adjacent to a dental implant in the right posterior mandible. Our experiences with these 2 cases suggest the possibility of a relationship between implant treatment and an inflammatory cofactor that might increase the risk of development of a malignant neoplasm.


Sujets)
Adulte , Sujet âgé , Humains , Carcinome épidermoïde , Implants dentaires , Odontologie , Mandibule , Sinus maxillaire , Sinusite maxillaire , Tumeurs de la bouche , Ostéomyélite , Péri-implantite , Plasmocytome
13.
Imaging Science in Dentistry ; : 165-174, 2017.
Article Dans Anglais | WPRIM | ID: wpr-157678

Résumé

PURPOSE: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. MATERIALS AND METHODS: Four geometric objects (cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. RESULTS: The mean VE ranged from −4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. CONCLUSION: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.


Sujets)
Amériques , Colloïdes , Tomodensitométrie à faisceau conique , Imagerie tridimensionnelle , Séoul
14.
Korean Journal of Medicine ; : 288-293, 2015.
Article Dans Coréen | WPRIM | ID: wpr-103793

Résumé

Combined peginterferon and ribavirin therapy for chronic hepatitis C is associated with several adverse side effects, but sudden deafness is uncommon. Here we report the case of a 62-year-old female with chronic hepatitis C (genotype 1b) who developed sudden deafness after completing 12 months of treatment with peginterferon alpha2a (180 microg/week) and ribavirin (1,000 mg/day). Pure-tone audiometry revealed a right-sided sensorineural hearing loss, which did not respond to 2 weeks of systemic corticosteroid therapy. Six months after the end of treatment for chronic hepatitis C, her qualitatively determined hepatitis C virus RNA level was 121,000 IU/mL. Following therapeutic failure, the patient was observed without retreatment for chronic hepatitis C or her hearing loss for a period of 12 months, during which time her hearing recovered almost completely.


Sujets)
Femelle , Humains , Adulte d'âge moyen , Audiométrie tonale , Ouïe , Perte d'audition , Surdité neurosensorielle , Perte auditive soudaine , Hepacivirus , Hépatite C chronique , Reprise du traitement , Ribavirine , ARN
15.
Korean Journal of Medicine ; : 303-307, 2015.
Article Dans Coréen | WPRIM | ID: wpr-103790

Résumé

A permanent inferior vena cava (IVC) filter with anti-coagulation therapy may be considered in patients with recurrent pulmonary embolism. IVC filter thrombosis is a challenging clinical problem. Here, we report our experience in treating one such patient using mechanical thrombectomy via the rolling technique with a 0.014-inch coronary wire.


Sujets)
Humains , Embolie pulmonaire , Thrombectomie , Thrombose , Filtres caves , Veine cave inférieure
16.
Imaging Science in Dentistry ; : 31-39, 2015.
Article Dans Anglais | WPRIM | ID: wpr-221771

Résumé

PURPOSE: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. MATERIALS AND METHODS: CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. RESULTS: The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. CONCLUSION: Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.


Sujets)
Animaux , Lapins , Tissu adipeux , Administration par voie intraveineuse , Anesthésie générale , Poids , Tomodensitométrie à faisceau conique , Produits de contraste , Oreille , Veine fémorale , Modèles animaux , Tomodensitométrie multidétecteurs , Radiographie , Glandes salivaires , Veines
17.
Imaging Science in Dentistry ; : 53-60, 2014.
Article Dans Anglais | WPRIM | ID: wpr-12989

Résumé

PURPOSE: This study was performed to investigate the incidence and configuration of the bifid mandibular canal in a Korean population by using cone-beam computed tomography (CBCT) imaging. MATERIALS AND METHODS: CBCT images of 1933 patients (884 male and 1049 female) were evaluated using PSR-9000N and Alphard-Vega 3030 Dental CT units (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan). Image analysis was performed by using OnDemand3D software (CyberMed Inc., Seoul, Korea). The bifid mandibular canal was identified and classified into four types, namely, the forward canal, buccolingual canal, dental canal, and retromolar canal. Statistical analysis was performed by using the chi-squared test and one-way analysis of variance (ANOVA). RESULTS: Bifid mandibular canals were observed in 198 (10.2%) of 1933 patients. The most frequently observed type of bifid mandibular canal was the retromolar canal (n=104, rate: 52.5%) without any significant difference among the incidence of each age and gender. The mean diameter of the accessory canal was 1.27 mm (range: 0.27-3.29 mm) without any significant difference among the mean diameter of each type of the bifid mandibular canal. The mean length of the bifid mandibular canals was 14.97mm(range: 2.17-38.8 mm) with only a significant difference between the dental canal and the other types. CONCLUSION: The bifid mandibular canal is not uncommon in Koreans and has a prevalence of 10.2% as indicated in the present study. It is suggested that a CBCT examination be recommended for detecting a bifid canal.


Sujets)
Humains , Mâle , Tomodensitométrie à faisceau conique , Incidence , Nerf mandibulaire , Prévalence , Radiographie , Séoul
18.
Journal of the Korean Geriatrics Society ; : 246-250, 2014.
Article Dans Coréen | WPRIM | ID: wpr-226410

Résumé

Gallstone ileus is a rare complication of the biliary stone, occurring in 0.3-0.5% of patients with cholelithiasis. The mortality rate is high at 12-27% and early diagnosis and prompt management can improve its prognosis. An 83-year-old woman was admitted to the hospital with abdominal pain. The patient previously had a hysterectomy and had received radiation therapy for uterine cancer. Plain abdominal x-ray showed typical findings of small bowel ileus with step ladder patterns. Computed tomography (CT) scan revealed biliary-enteric fistula with a 3-cm-sized gallstone in the jejunal loop. Surgical treatment was planned but due to the patient's wish, conservative treatment was provided for 10 days. In the follow-up CT scan, the stone had moved to the distal ileum but intestinal perforation was suspected. Ileocecectomy and adhesiolysis were performed and the patient recovered fully. Here we report a case of gallstone ileus that was treated by surgical removal after 10 days of conservative treatment.


Sujets)
Sujet âgé de 80 ans ou plus , Femelle , Humains , Douleur abdominale , Lithiase biliaire , Diagnostic précoce , Fistule , Études de suivi , Calculs biliaires , Hystérectomie , Iléum , Iléus , Perforation intestinale , Mortalité , Pronostic , Tomodensitométrie , Tumeurs de l'utérus
19.
Imaging Science in Dentistry ; : 265-270, 2012.
Article Dans Anglais | WPRIM | ID: wpr-90541

Résumé

Primary intraosseous squamous cell carcinoma (PIOSCC) is a rare carcinoma, which arises within the jaws without connection to the oral mucosa and presumably develops from a remnant of odontogenic epithelium. We present a case of solid type PIOSCC in a 52-year-old male patient complaining of dull pain on his left lower molar. In this case, early stage PIOSCC mimicking a periapical lesion might lead to a one-year delay in treatment due to the misdiagnosis of osteomyelitis after extraction of the third molar. The clinical, radiological, and histologic features are described. In this case, there was initial radiographic evidence for PIOSCC mimicking a periapical lesion. Incautious radiographic interpretation and treatment procedures had delayed the correct diagnosis and resulted in extensive bony destruction during the patient's disease progression.


Sujets)
Humains , Mâle , Adulte d'âge moyen , Carcinome épidermoïde , Erreurs de diagnostic , Évolution de la maladie , Épithélium , Tumeurs de la tête et du cou , Mâchoire , Mandibule , Molaire , Dent de sagesse , Muqueuse de la bouche , Ostéomyélite , Maladies périapicales
SÉLECTION CITATIONS
Détails de la recherche